Dansereau Dental. P r e - C o n s t r u c t i o n G u i d e

Size: px
Start display at page:

Download "Dansereau Dental. P r e - C o n s t r u c t i o n G u i d e"

Transcription

1 P r e - C o n s t r u c t i o n G u i d e A m e r i c a s D e n t a l E q u i p m e n t C o m p a n y Dansereau Dental (800) / M a n u fa c t u r e d i n U S A f o r 4 5 Y e a r s

2 DANSEREAU HEALTH PRO DUCTS, INC. AM ERIC A S DENT AL EQU I PMENT COMPAN Y TABLE OF CONTENTS Dansereau Health Products dental operatories Dansereau Health Products dental air compressor Dansereau Health Products dental vacuum pump Dental X-ray Specifications/Requirement/Electrical Dental X-ray in-wall backing Dental X-ray Pass-thru cabinet Water Solenoid and Filtration System GENERAL INFORMATION There are three types of dental delivery systems used in a Standard General Practitioner s dental office. 1) The over the patient delivery system (Chair mounted light and dental unit). 2) The rear service delivery system: this can be in the form of a cart or mounted to a cabinet in the rear of the operatory or at the head of the patient. 3) The side delivery system: This can also be in the form of a cabinet or cart that is installed to the side of the dental chair. The plumbing for each of these systems varies by the specifications of the equipment to be installed and the location of the plumbing required to operate the dental equipment. Be aware that some of the requirements are subtle, carefully, review the list of equipment to be installed and, verify with equipment supplier the proper schematics are being used in the construction of the dental office. If you are not sure of the specific requirements needed to properly install the dental equipment contact Dansereau Health Products, Inc. immediately. The most common recurring problem - is the contractor not contacting the dental equipment supplier and verifying the dental equipment to be installed is the same as the schematics that have been supplied to the contractor. (MAKE SURE IF A DENTAL DELIVERY SYSTEM HAS A CUSPIDOR THAT A 2" DRAIN HAS BEEN INSTALLED BY THE CONTRACTOR).

3 DENTAL OPERATORIES - NO CUSPIDORS Critical Note: Uniform Plumbing Code Requires all Dental Delivery Systems using Public Water supply must have an external Vacuum Breaker. Verify this with your local Building and Safety Department. If you are using Self Contained Water Systems you will NOT be required to Install an external Vacuum Breaker. America Operatory Universal Operatory Clinic Operatory

4 DENTAL OPERATORIES - WITH CUSPIDORS Critical Note: Uniform Plumbing Code Requires all Dental Delivery Systems using Public Water supply must have an external Vacuum Breaker. Verify this with your local Building and Safety Department. You will require Public Water to properly operate your Cuspidor System. America Operatory Cuspidor Added to Chair Mounted Delivery System Requires Drain Reduced to 1 Clinic Operatory

5 12 O CLOCK OPERATORY PACKAG ES Critical Note: Uniform Plumbing Code Requires all Dental Delivery Systems using Public Water supply must have an external Vacuum Breaker. Verify this with your local Building and Safety Department. Realize that Rear or 12 O clock Operatories require additional length for appropriate performance.

6 AIR COMPRESSOR Location The DHP Dental Air Compressor should be installed in a well ventilated area. The DHP Dental Air Compressor is air cooled and without proper air circulation its lifespan could be shortened significantly. The sound level of the Dental Air Compressor when in operation, should be considered when locating an area within the dental office for the Dental Air Compressor. It is strongly recommended that insulation should be added to the walls adjacent to the Dental Air Compressor. The ambient temperature in the dental office equipment room should never exceed 40 degrees Fahrenheit minimum and 100 degrees Fahrenheit maximum. The dental office equipment room will require a minimum of 5 air changes per hour which can be met with a 50 CFM vent fan in a 5' x 5' x 9' room. The DHP Dental Air Compressor can be located outside of the dental office; however, it is extremely important the air compressor be covered from the elements, as well as, have the proper ventilation as previously mentioned. It is strongly recommended that visual inspections of the air compressor be done on a weekly basis. Electrical Requirements LINE VOLTAGE - Single phase 120v/60hz or 240/60hz electricity is required for proper operation of the DHP Dental Air Compressor. All electrical sources to the DHP Dental Air Compressors MUST BE PROPERLY GROUNDED! CRITICAL: All DHP Dental Air Compressors require a dedicated electrical source. Refer to the Compressor Specifications to confirm amperage. Plumbing Requirements AIR LINE - A 1/2" copper male pipe thread fitting in the utility closet end of the air line to the operatories is required to attach the Dental Air Compressor supply line. NOTE: The DHP Dental Air Compressor regenerating desiccant drying system will expel a minimal amount of moisture and it is recommended that the 1/4" poly - tubing be situated in either a floor sink, drain or small bucket that can be emptied as needed. Fresh Air Intake Many Local Building Departments are requiring Fresh Air Intake Dedicated Vent Lines for dental air compressors. It is a 2 Vent Pipe through the roof or side of a building in which the dental air compressor would receive the outside air to compressor intake filters. The Roof Top Pipe would require a vent cap to protect rain, snow, or dust from entering Fresh Air Intake line.

7 SUPER FLOW DRY VACUU M Location The DHP Vacuum Pump should be installed in a well ventilated area. The DHP Vacuum Pump is air cooled and without proper air circulation the lifespan of the vacuum pump could be shortened significantly. The sound level of the vacuum pump, when in operation, should be considered when locating an area within the dental office for the vacuum pump. It is strongly recommended that insulation should be added to the walls adjacent to the vacuum pump. The ambient temperature in the dental office equipment room should never exceed 40 degrees Fahrenheit minimum and 100 degrees Fahrenheit maximum. A Climate Controlled Utility Room is strongly recommended. Electrical Requirements LINE VOLTAGE - Single phase 240v/60hz - 20A electricity is required for proper operation of the DHP Vacuum Pump. All electrical sources to the DHP Vacuum Pump MUST BE PROPERLY GROUNDED! LOW VOLTAGE - The DHP Super Flow 10 Dry Vacuum Pump has an ON/OFF low voltage capability. A 18/3 low voltage rated wire can be run from one central location to allow the DHP Vacuum Pump to be turned on and off. NOTE: DHP Super Flow 10 Dry Vacuum System a minimum 230V Single Phase Electrical Supply, 208V you will need a Buck Boost Transformer to increase the voltage to 230V. Plumbing Requirements WATER LINE - A 1/2" cold water source is required for proper Rinsing of the Vacuum Storage Tank. A 1/2" Ball Valve is required at the end of the water source. Cold water is not a required for operation of the Dry Vacuum System, but the Rinse Cycle of Storage Tank will eliminate maintenance of the Dry Vacuum System. WASTE LINE - The industry standard for exhausting the Dry Vacuum System waste is to exhaust the waste into a floor sink or a 'P' trap. Local Building Codes require a 1" air gap for waste disposal. Vacuum Line Refer to the Vacuum Line Sizing Chart to Vacuum Line Sizing. It is strongly recommended that you contact your local building department and inquire if schedule 40 PVC is acceptable to use in the vacuum line system fabrication. Dansereau Strongly Recommends PVC as the Vacuum Line. Vent Line The Super Flow 10 Dry Vacuum Turbine requires an exhaust vent. The Turbine Motor runs at a warm level and a 2 Metal Pipe for the first 6 feet from the Turbine Motor is required. After the 6 feet of metal pipe (Galvanized or Black Pipe, not copper) you may use Schedule 80 PVC. The Turbine Motor Exhaust Pipe must penetrate the roof or side of the building. No debris shall go into the vent!!! UNDER NO CONDITIONS SHOULD CONTINUOUS RUN SINKS OR DENTAL CUSPIDORS BE INSTALLED ON A VACUUM LINE

8 WET VACUUM SYSTEMS OVERHEAD PLUMBING Overhead plumbing for dental vacuum lines are not recommended. Our experience in the long term there can be issues with quality of vacuum. However, if it is required based upon existing conditions in a dental office, economic considerations or construction limitations you will need to be exact in following the rules listed below. Incorrect installation of overhead vacuum piping will ensure low quality or non existent vacuum pressure. Plumbing Rules for Overhead Piping: Keep the vertical lift height as short as possible. The vertical pipe must tee into the top of the horizontal line. Run the vertical line in 1/2 pipe. Run the horizontal overhead line in 1-1/2 or preferably 2 size pipe. For more than 5 Operatories consult with Dansereau. Nitrous oxide scavengers must run in a separate vertical pipe and tee into the top of the horizontal line in a separate location from the wet vertical pipe. Pump Sizing Rules for Overhead Piping: Dry Vacuum System is only recommended Vacuum System. Consult with Dansereau on Overhead Piping Line Size. Operator Rules for Overhead Piping: Operators must use Non Foaming Vacuum Line Cleansers ( Recommended Bio-Pure) Operators must flush lines and then allow air from open vacuum line to run in order to ensure complete liquid non foaming vacuum line cleaning solution has run through the system. Vertical Pipes Must Tee Into Top of Horizontal Overhead Pipe General Principles for Vacuum Lines Slope a minimum of 1/4 in 10 feet with the low end towards the tank. If an in-line low spot is unavoidable, place it in a known location and incorporate a Clean Out. Confirm All Local Building Codes prior to beginning plumbing.

9 VACUUM LINE SPECIFIC ATIONS Vacuum Line: Schematics Dansereau Health Products, Inc. strongly recommends Schedule 40PVC for use as the Vacuum Line. However, be aware some Building Codes require a metal type vacuum line and require Copper as the Vacuum Line. Copper will eventually deteriorate over years of service, Schedule 40 PVC will not. NOTE: IF YOUR VACUUM LINE INSTALLATION IS OUTSIDE THE SCOPE LISTED BELOW CONTACT DANSEREAU FOR SPECIAL INSTRUCTIONS. Surface Mt J Box 1 Sch 40 PVC Bushing Sch 40 PVC 1.5 DWV Sanitary T Sch 40 PVC Site Requirements: Environment Conditions Operating Conditions - Indoor use at altitudes up to 2000M. Temperature 5 to 40 Degrees C (41 to 104 F) Maximum relative humidity 80% for temperatures up to 31 C, decreasing lineally to 50% relative humidity to 40C. Supply Voltage fluctuation of +/- 10% of nominal voltage. IEC Not suitable for use in the presence of a flammable anesthetics mixture with air or with oxygen or nitrous oxide. Class 1 Installation Category Ordinary equipment (IPXO). Does not protect against ingress of water. Unit is suitable for continuous operation.

10 VACUUM SYSTEM PIPING Vacuum Line Sizing Chart NUMBER OF VACUUM LINE PIPE DIAMETER OPERATORIES PVC sch 40 RISER DIAMETER 1 1 1/4" /4" /4" /2" /2" 1 6 2" 1 7 2" 1 8 to 12 2" 1 M o s t C o m m o n V a c u u m P l u m b i n g E r r o r s Do not allow any pipe to branch off Another Pipe below the centerline of the main or Branch line pipe IMPORTANT: To prevent suction loss do not allow a trap to be plumbed at any location in the system except main line riser assembly and overhead vertical riser. B r a n c h L i n e T e r m i n a t i o n T o T w o O p e r a t o r i e s This Branch Line Termination is shown INCORRECTLY This Branch Line Termination is shown Correctly

11 WET VACUUM SYSTEMS LOCATION The DHP Vacuum Pump should be installed in a well ventilated area. The DHP Vacuum Pump is air cooled and without proper air circulation the lifespan of the vacuum pump could be shortened significantly. The sound level of the vacuum pump, when in operation, should be considered when locating an area within the dental office for the vacuum pump. It is strongly recommended that insulation should be added to the walls adjacent to the vacuum pump. Climate Controlled Utility Rooms are recommended. Electrical Requirements LINE VOLTAGE - Single phase 120v/60hz or 240v/60hz electricity is required for proper operation of Vacuum Pumps. All electrical sources to the DHP Vacuum Pump MUST BE PROPERLY GROUNDED! Verify Electrical 120v or 240v with Equipment Co. LOW VOLTAGE - The Vacuum Pump requires a 18/3 low voltage wire to central location for On/Off Switching (Panel to be Supplied by Equip. Co). Plumbing Requirements WATER LINE - A 1/2" cold water source is required for proper operation of the DHP Vacuum Pump. A 1/2" shut off valve is required at end of the water source. WASTE LINE - Vacuum pump waste will exhaust the waste into an Air/Water Separator with the waste ending in a floor sink or a ' P ' trap. Local Building Codes will require a 1" air gap from the exhaust of the Air/Water Separator into the waste receptical. Vacuum Line Refer to the Vacuum Line Sizing Chart. Dansereau Strongly recommends PVC Vacuum Lines. Current Building Codes may not allow schedule 40 PVC and may require copper as substitute. Contact your local building department regarding schedule 40 PVC, if it is acceptable for use in the vacuum line system. Vent Line Air Water Separators are required by many Building Codes. You will need to have a 2 Vent Line installed from the Separator thru the roof. UNDER NO CONDITIONS SHOULD CONTINUOUS RUN SINKS OR DENTAL CUSPIDORS BE INSTALLED ON A VACUUM LINE SPECIAL NOTE: City and County of Los Angeles Require an Atmospheric Vacuum Breaker to be Installed No Less than 12 Inches from the Water Source in the Utility Room Recommend: WATTS 1/2 Max PSI 125 / Max Temp. 212 Plumbers Responsibility

12 UTILITY ROOM SWITCHI NG 1 Low Voltage Control Panel Low Voltage Transformer DHP Air Compressor Oil Less - 1 HP 4 DHP 1 HP Vacuum Pump 5 Water Solenoid Filter System NOTE: This is typical dental office design and layout indicating standard locations for the dental air compressor, vacuum system and the appropriate switching for their use. If you need information on specific existing conditions contact Dansereau for specifications.

13 TYPICAL UTILITY ROO M NOTE: Note this is a typical Wet Vacuum Air Water Separator Configuration. This is a Typical Utility Room configuration. Use this as a basic format for designing your Utility Room. Key elements are appropriate electrical and plumbing specs. need to be met, placement of electrical and plumbing can be modified if needed. Contact Dansereau to verify modifications prior to installation of electrical and plumbing connections. Note this is a typical Wet Vacuum Air Water Separator Configuration.

14 X RAY MACHINES LOCATION Dental X - ray Machines can be mounted either in a Pass Thru Cabinet or a Standard Wall Mounted Installation. A Pass Thru Cabinet will allow the X - ray Machine to Swing between 2 Dental Operatories. A Pass Thru X - ray Machine typically requires a longer X - ray Arm or the dental chairs have a swivel mechanism. A Standard Wall Installation is designated for a single operatory use. Usually you will have a standard length X - ray Arm, in some instances, a shorter X - ray Arm can be used. The Control Box for operating the X - ray machines can be installed within the dental operatory or x- ray pass thru cabinet, however, most agree installation of the X - ray Control Box in an area outside, but capable of viewing the patient, is the best installation. This would require the electrician to install wiring prior to the completion of Drywall on new installations. It is recommended that a complete installation guide be available to the contractor and electrician during construction for proper placement of key support items. Electrical Requirements LINE VOLTAGE - Single phase 120v/60hz electricity is required for proper operation of Dental X - ray Machines. All electrical sources to Dental X - ray Machines MUST BE PROPERLY GROUNDED! All Dental X - ray Machines require a minimum 20 Amp Dedicated Circuit. It is Imperative the Lead, Neutral and Ground all be isolated to one circuit, as all Dental X - ray Machines manufactured today are Digital and extremely sensitive to outside electrical stimuli. Using a joint neutral or ground could effect the Digital X - ray Sensor performance. Standard Pass Thru X - ray Installation - Important Verify X - ray Manufac- Standard Electrical Requirements: 120VAC +/- 10@ ( VAC) Dedicated Circuit with Minimum 15Amp Wire Size 14AWG if Less than 50 Feet Run Wire Size 12AWG if More than 50 Feet Run 75 Feet Run or More Require 10AWG Wire Between Main Controller and Sub Controller 20AWG 300V is recommended

15 X RAY MACHINES Pass Thru X ray Framing and Support Specifications CAUTION!!! If the X-RAY is mounted in a manner other than specified by Belmont Mfg the support of the wall must be checked and verified to be adequate. Critical Element All Wire to be thru this Hole!!! Electrical Requirements: Power Supply 120VAC=/-10% with a 3 Wire Grounded Dedicated Circuit. 20 Amperes - Wire Size 12AWG - Line Voltage must be within 2-3% at 10.8 Amps. Interconnecting wiring between Sub Controller and Main Controller 4 Conductor, 20AWG, 300V with a Maximum wire run of 33 feet Sub Controller must be mounted in a manner that it will withstand a 10lb shear load. Main Controller: The Main Controller of the Photx is designed to mount on two 2 x 4 wood studs with 16 centers. The wall mounting hardware must be sufficient to withstand a 100lb shear load and a 450 drawal force.

16 X RAY MACHINES Pass Thru X ray Framing and Support Specifications CAUTION!!! 49 If the X-RAY is mounted in a manner other than specified by Belmont Mfg the support of the wall must be checked and verified to be adequate. 13 Mounting Plate Location requires door hinges to be within 3 from bottom of cabinet 4 X 4 Post NOTE: Critical Element is Location of ELT Wire from the Main Controller Electrical Requirements: Power Supply 120VAC=/-10% with a 3 Wire Grounded Dedicated Circuit. 20 Amperes - Wire Size 12AWG - Line Voltage must be within 2-3% at 10.8 Amps. Interconnecting wiring between Sub Controller and Main Controller 4 Conductor, 20AWG, 300V with a Maximum wire run of 33 feet Critical Element All Wire to be thru this Hole!!! Main Controller: The Main Controller of the Photx is designed to mount on two 2 x 4 wood studs with 16 centers. The wall mounting hardware must be sufficient to withstand a 100lb shear load and a 450 drawal force. Sub Controller must be mounted in a manner that it will withstand a 10lb shear load.

17 DENTAL WAT ER SOLENOI D FILTR AT ION SYSTEM A Water Solenoid Filtration System is strongly recommended for all dental offices. The Water Solenoid Filtrations System is installed on the Incoming Cold Water Line of the Dental Office. The system has two features. The Solenoid Valve is designed to be turned off when the dentist and staff leave at the end of the business day. It will electronically turn off the water to the dental office prohibiting any water leaks that could occur when the staff and dentist are not in the office. Secondly, the Water Filtration System is designed to remove the particulate matter from the water source. This will prolong the lifespan of the micro valves for the dental units. This is not a substitute for a distilled water system, which is used for autoclaves sterilizers and self contained water systems. The information contained in this manual is a collection of typical installation requirements that if properly followed, will ensure your Dansereau equipment will easily and proficiently install. We recommend that State Licensed Contractors complete the items outlined in this manual. All construction and installations are unique and consideration should be given when you are following the diagrams contained in this manual. If you have concerns or are unfamiliar with these diagrams contact Dansereau Health Products, Inc at ( 800 ) , prior to beginning the work. Any information given in this manual does not supersede National or Local Building Codes or specifications given by the licensed contractor responsible for the work.

A m e r i c a s D e n t a l E q u i p m e n t C o m p a n y. Rev 2/15. D a n s e r e a u

A m e r i c a s D e n t a l E q u i p m e n t C o m p a n y. Rev 2/15. D a n s e r e a u A m e r i c a s D e n t a l E q u i p m e n t C o m p a n y Rev 2/15 D a n s e r e a u (8 0 0 ) 423-5657 / WWW.DHPDENTAL.COM CUSTOMER SUPPORT INF ORMATION Dansereau Health Products, Inc. has been manufacturing

More information

PRE-INSTALLATION GUIDE

PRE-INSTALLATION GUIDE Dry Vacuum System Part Numbers V3, V5, V7, 2V3, 2V3CT, 2V5, 2V5CT, 2V7, 3V5 and 4V5 PRE-INSTALLATION GUIDE All pumps comply with NFPA 99C level 3 requirements. All installations must conform to local codes.

More information

Equipment Alert. P-Trap Must Be Installed to Exhaust or Warranty will be Voided. Refer to this Manual for installation Instructions

Equipment Alert. P-Trap Must Be Installed to Exhaust or Warranty will be Voided. Refer to this Manual for installation Instructions Dry Assembled Elbows MUST Glue when Installed Exhaust Connection P-Trap Must Be Installed to Exhaust or Warranty will be Voided AA2360 Refer to this Manual for installation Instructions 2011 Midmark Corp.

More information

PRE-INSTALLATION GUIDE

PRE-INSTALLATION GUIDE DENTAL VACUUM SYSTEMS PRE-INSTALLATION GUIDE for MODELS VS50, VS50H, VS80 & VS80H Model VS50 Model VS50H Model VS80 Model VS80H This VacStar Model is being installed: (AS CHECKED) VS50 VS80 VS50H VS80H

More information

PRE-INSTALLATION GUIDE

PRE-INSTALLATION GUIDE DENTAL VACUUM SYSTEMS PRE-INSTALLATION GUIDE for MODELS VS20 & VS40 Check VacStar Model Being Installed: VS20 VS40 Model VS20 Model VS40 Doctor: Address: Phone#: Dealer: Dealer Address: PRODUCT SPECIFICATIONS

More information

PRE-INSTALLATION GUIDE

PRE-INSTALLATION GUIDE Dry Vacuum System Part Numbers V15, 2V15, 3V15 and 4V15 PRE-INSTALLATION GUIDE All pumps comply with NFPA 99C level 3 reuirements. All installations must conform to local codes. System being installed:

More information

Installation & Operation

Installation & Operation 2 PVC Vent Pipe 2 PVC Vent Connection (Vent connected to outdoors) 65 (165cm) Conduit (Provided) Disconnect Box (Provided By Electrician) (1 box per pump) 1/4 Comp x 1/4 Comp x 60 (153cm) See notes on

More information

Vacuum Plumbing Layout Recommendations

Vacuum Plumbing Layout Recommendations Vacuum Plumbing Layout Recommendations Intended Use To provide general dental vacuum plumbing layout recommendations per industry standards. Installation should be conducted by qualified dental/plumbing

More information

PRE-INSTALLATION GUIDE for MODELS

PRE-INSTALLATION GUIDE for MODELS DENTAL VACUUM SYSTEMS PRE-INSTALLATION GUIDE for MODELS VS20NEO & VS40NEO Check VacStar NEO Model Being Installed: VS20NEO VS40NEO Model VS20NEO Model VS40NEO Doctor: Address: Phone#: Dealer: Dealer Address:

More information

PRE-INSTALLATION GUIDE for MODELS

PRE-INSTALLATION GUIDE for MODELS DENTAL VACUUM SYSTEMS PRE-INSTALLATION GUIDE for MODELS VS50NEO & VS80NEO Check VacStar NEO Model Being Installed: VS50NEO VS80NEO Doctor: Address: Phone#: Dealer: Dealer Address: PRODUCT SPECIFICATIONS

More information

STERI-VAC CENTRAL SUCTION SYSTEM

STERI-VAC CENTRAL SUCTION SYSTEM STERI-VAC CENTRAL SUCTION SYSTEM INSTALLATION MANUAL This is a general installation manual for Steri-Vac Central Suction Systems. For detailed information see specific technical sheet. These are high-volume

More information

INSTALLATION MANUAL. Manufactured by AQUA-AIR MANUFACTURING. (801) or (800) FAX (801)

INSTALLATION MANUAL. Manufactured by AQUA-AIR MANUFACTURING. (801) or (800) FAX (801) INSTALLATION MANUAL Manufactured by AQUA-AIR MANUFACTURING 542 W. 47 Confluence East 800 South, Ave., Salt Ivins, Lake Utah City, 84738 Utah 84123 (801) 265-9699 or (800) 916-5777 FAX (801) 268-3856 (435)

More information

DENTAL VACUUM SYSTEM Part Numbers: VS2O, VS40, VS50, VS50H, VS80 and VS80H RECOMMEND DAILY USE OF MONARCH CLEANSTREAM USER S MANUAL

DENTAL VACUUM SYSTEM Part Numbers: VS2O, VS40, VS50, VS50H, VS80 and VS80H RECOMMEND DAILY USE OF MONARCH CLEANSTREAM USER S MANUAL DENTAL VACUUM SYSTEM Part Numbers: VS2O, VS40, VS50, VS50H, VS80 and VS80H RECOMMEND DAILY USE OF MONARCH CLEANSTREAM USER S MANUAL TABLE OF CONTENTS SECTION PAGE Congratulations.... 3 Purpose of this

More information

PowerVac G Single to Twin Conversion Kit [ ]

PowerVac G Single to Twin Conversion Kit [ ] PowerVac G Single to Twin Conversion Kit [002-1371-00] warning Motors are thermally protected with automatic reset. Unit may start without warning. Caution Vac unit weighs 375 lbs (170 kgs). Use care when

More information

Read Only Document Not For Distribution

Read Only Document Not For Distribution Chapter 14 Special Requirements For Health Care Facilities 14.1 GENERAL This Chapter applies to special fixtures and systems that occur in health care facilities and to the special plumbing requirements

More information

DENTAL AIR SYSTEM. AS12, AS22, AS50 AS70, AS12C, AS22C & AS50C International. Installation and Operation Manual

DENTAL AIR SYSTEM. AS12, AS22, AS50 AS70, AS12C, AS22C & AS50C International. Installation and Operation Manual DENTAL AIR SYSTEM AS12, AS22, AS50 AS70, AS12C, AS22C & AS50C Installation and Operation Manual TABLE OF CONTENTS SECTION PAGE SECTION PAGE Safety Instructions... 2 Site Requirements... 6 Congratulations...

More information

USER MANUAL/Installation Instructions LRV-4

USER MANUAL/Installation Instructions LRV-4 USER MANUAL/Installation Instructions LRV-4 Sierra Dental Products LLC 1953 W Gulf to Lake Hwy, Lecanto, FL 34461 Ofc.# 352-527-1975 FAX# 352-513-4801 www.dentalvacuums.com Email: Sierradentalproducts@Outlook.com

More information

Special Requirements For Health Care Facilities

Special Requirements For Health Care Facilities Chapter 14 Special Requirements For Health Care Facilities 14.1 GENERAL This Chapter applies to special fixtures and systems that occur in health care facilities and to the special plumbing requirements

More information

Dishwasher Installation Instructions DW 24XT/DW 24XV

Dishwasher Installation Instructions DW 24XT/DW 24XV Dishwasher Installation Instructions DW 24XT/DW 24XV Installation Instructions Dishwasher BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT Observe all governing codes and ordinances.

More information

A PROUD HERITAGE OF EXPERIENCE & QUALITY DISHWASHER BR-DWSH01-S

A PROUD HERITAGE OF EXPERIENCE & QUALITY DISHWASHER BR-DWSH01-S A PROUD HERITAGE OF EXPERIENCE & QUALITY DISHWASHER BR-DWSH01-S, 1 6 7 $ / / $ 7, 2 1, 1 6 7 5 8 & 7, 2 1 6 W W W. V I N O T E M P. C O M Installation Instructions Dishwasher BEFORE YOU BEGIN Read these

More information

INSTALLATION MANUAL GEO-BOOST GROUND LOOP HEAT EXCHANGER

INSTALLATION MANUAL GEO-BOOST GROUND LOOP HEAT EXCHANGER 1103 N HIGH CROSS RD URBANA, IL 61802 1-773-492-1893 INSTALLATION MANUAL GEO-BOOST GROUND LOOP HEAT EXCHANGER REV 1.0 The Geo-Boost system consists of the Geo-Boost heat exchanger and a relay controller

More information

Install Configurations

Install Configurations Table of Contents EQUIPMENT SPECS: 1 WATER SUPPLY CONFIGURATIONS 2 OPTION 1 (OPTIMIZED): BRING WATER TO MACHINES 2 OPTION 2 (ENHANCED): INSTALLING A DEDICATED WATER SOURCE 3 OPTION 3 (ENHANCED CONT.):

More information

PARALLEL RACK SYSTEM INSTALLATION & OPERATIONS MANUAL With Master Rack Compressor Sequencer

PARALLEL RACK SYSTEM INSTALLATION & OPERATIONS MANUAL With Master Rack Compressor Sequencer PARALLEL RACK SYSTEM INSTALLATION & OPERATIONS MANUAL With Master Rack Compressor Sequencer 5/16 Rev. A 57-02509 2 Contents INTRODUCTION... 4 WARNING LABELS AND SAFETY INSTRUCTIONS... 5 PS SERIES PARALLEL

More information

Advantage Series Bathing System Specifications

Advantage Series Bathing System Specifications Advantage Series Bathing System Specifications 6000 Series 6300 Series 450 Main Street, Somerset, WI 54025 Phone: 715.247.5625 Fax: 715.247.3424 http://www.apollobath.com The information in this manual

More information

Performer Cuspidor. Installation Instructions. (For Performer III Chair & International Performer I Chair) You Will Need. About This Install

Performer Cuspidor. Installation Instructions. (For Performer III Chair & International Performer I Chair) You Will Need. About This Install Installation Instructions Performer Cuspidor (For Performer III Chair & International Performer I Chair) You Will Need Adjustable wrench or 9/16" open-end wrench Magnetic leveling device 3/16" hex key

More information

NCC199CDV Commercial Water Heating System Installation Manual

NCC199CDV Commercial Water Heating System Installation Manual NCC199CDV Commercial Water Heating System Installation Manual -Additional information can be obtained from the appliance manual. Floor Mount Rack (CDV Units) 6 Water Heaters Floor Mount Rack (w/ VC-6)

More information

INSTALLATION GUIDE Dual Fuel Ranges

INSTALLATION GUIDE Dual Fuel Ranges INSTALLATION GUIDE Dual Fuel Ranges Contents Wolf Dual Fuel Ranges......................... 3 Safety Instructions............................ 4 Dual Fuel Range Specifications.................. 5 Dual Fuel

More information

A PROUD HERITAGE OF EXPERIENCE & QUALITY DISHWASHER BR- DWSH01- S

A PROUD HERITAGE OF EXPERIENCE & QUALITY DISHWASHER BR- DWSH01- S A PROUD HERITAGE OF EXPERIENCE & QUALITY DISHWASHER BR- DWSH01- S W W W. V I N O T E M P. C O M Installation Instructions Dishwasher BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT

More information

DRYMAX DRYMAX DRYMAX DRYMAX

DRYMAX DRYMAX DRYMAX DRYMAX DRYMAX DRYMAX 897-8485 DRYMAX DRYMAX 905 RECEIVING AND INSPECTION 1. The dryer cannot be tilted on its side or upside down during shipping. 2. Use forklift from the bottom of the dryer when installing

More information

TMB Baking TSV Gas Oven TAG Series. Contractor s Utility Requirements

TMB Baking TSV Gas Oven TAG Series. Contractor s Utility Requirements TMB Baking TSV Gas Oven TAG Series Contractor s Utility Requirements NATURAL GAS FIRED - INSTALL INSTRUCTIONS - This Manual is prepared for the use of licensed utility contractors. All gas, electrical,

More information

900 N. Via Piemonte Ontario, CA

900 N. Via Piemonte Ontario, CA 2 3 L 8 5'-0" 6'-1" 5'-0" 4'-0" 2'-0" D.5 6" 9'-9" K 2 1 2 " 5'-0" 2'-0" 1'-2" 8" 4 4.3 7'-0" C.6 1'-8 1 2 " 7'-0" 8" 10'-6" 5'-0" 8" 6" 6'-6" 6'-3" PLUMBING SCOPE OF WORK - DRAINS 7'-3" 6'-8" KEC TO PROVIDE:

More information

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS VIKING 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 IMPORTANT - PLEASE READ AND FOLLOW Before beginning - please read these instructions

More information

Technical Specifications & Pricing

Technical Specifications & Pricing Nu/Clean Model 510 Recirculating Water Deionizer Inline Aqueous Cleaning System for Closed Loop, Zero Discharge Operations Technical Specifications & Pricing The base machine in its standard configuration

More information

Installation Instructions

Installation Instructions GE Consumer & Industrial Appliances Installation Instructions Junction Box Cover Within this user bag, you will find a junction box cover and a #10 hex head screw used to attach the junction box cover

More information

PORTER INSTRUMENT COMPANY, INC. 245 TOWNSHIP LINE RD. P.O. BOX 907 HATFIELD, PA USA [215] / FAX [215]

PORTER INSTRUMENT COMPANY, INC. 245 TOWNSHIP LINE RD. P.O. BOX 907 HATFIELD, PA USA [215] / FAX [215] PORTER INSTRUMENT COMPANY, INC. 245 TOWNSHIP LINE RD. P.O. BOX 907 HATFIELD, PA 19440-0907 USA [215] 723-4000 / FAX [215] 723-2199 USER INSTRUCTIONS FOR ASSEMBLY INSTALLATION AND CLEANING PORTER Scavenger

More information

Built-In Dishwasher. Installation Instructions. BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT The dishwasher MUST be

Built-In Dishwasher. Installation Instructions. BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT The dishwasher MUST be Installation Instructions Built-In Dishwasher If you have questions, call 800.GE.CARES (800.432.2737) or visit our website at: www.ge.com BEFORE YOU BEGIN Read these instructions completely and carefully.

More information

Multi-Function Cooktop

Multi-Function Cooktop INSTALLATION GUIDE Multi-Function Cooktop Contents Wolf Multi-Function Cooktop.................... 3 Multi-Function Cooktop Specifications............ 4 Multi-Function Cooktop Installation...............

More information

APPLICATION DATA SHEET

APPLICATION DATA SHEET APPLICATION DATA SHEET General Piping Recommendations and Refrigerant Line Length for Split-System Air Conditioners and Heat Pumps GENERAL GUIDELINES This Split-System (Air Conditioning Condensing/Heat

More information

PROBLEM CAUSE CORRECTIVE ACTION. Product Service Replace cup. Malfunction of cup. Detergent cup fails to open. Malfunction of relay

PROBLEM CAUSE CORRECTIVE ACTION. Product Service Replace cup. Malfunction of cup. Detergent cup fails to open. Malfunction of relay CHAPTER 7 TROUBLESHOOTING Refer to the following table if your Glassware Washer fails to operate properly. If the suggested corrective actions do not solve your problem, contact Labconco for additional

More information

VetPro Solo Installation

VetPro Solo Installation VetPro Solo Installation warning Equipment is not suitable for use in the presence of a flammable anesthetic mixture. - Umbilical & Foot Control Cord Entry City Water Inlet Connection Caution Use caution

More information

Top Control Dishwasher

Top Control Dishwasher INSTALLATION GUIDE Top Control Dishwasher NS-DWH2BS8/NS-DWH2SS8/NS-DWR2BS8/NS-DWR2WH8/NS-DWR2SS8 Before using your new product, please read these instructions to prevent any damage. Contents Introduction......................................................................................................

More information

Dental Unit User's Guide

Dental Unit User's Guide Dental Unit User's Guide MDD 93/42/EEC May 1999 8200590 Quint-7000 User's Guide We reserve the right to make changes. Manufactured by: FINNDENT OY Teollisuustie 5 FIN-07230 MONNINKYLÄ Tel. +358 19 5221500

More information

B.C.S. Shop Heaters 26, 30 & 36 (36 shown)

B.C.S. Shop Heaters 26, 30 & 36 (36 shown) BIOMASS COMBUSTION SYSTEMS, INC. 67 MILLBROOK ST., SUITE 502 WORCESTER, MA 01606 508-798-5970 - FAX 508-798-5971 B.C.S. Shop Heaters 26, 30 & 36 (36 shown) INSTALLATION MANUAL HAND FIRED SYSTEMS 8-09 Biomass

More information

COBRA -H EXTRACTOR 120V

COBRA -H EXTRACTOR 120V COBRA -H EXTRACTOR 120V INFORMATION & OPERATING INSTRUCTIONS CAUTION: DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTION MANUAL IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY

More information

CENTRAL AIR CONDITIONER SPLIT SYSTEM

CENTRAL AIR CONDITIONER SPLIT SYSTEM CENTRAL AIR CONDITIONER SPLIT SYSTEM WITH ELECTRONIC CONTROL SERIES: DS INSTALLATION INSTRUCTIONS INDEX GENERAL... 2 UNIT LOCATION CRITERIA... 2 DIMENSIONAL DRAWINGS... 3 INDOOR UNIT INSTALLATION... 5

More information

CLASSIC. SIDE CABINET Installation Instructions

CLASSIC. SIDE CABINET Installation Instructions CLASSIC SIDE CABINET Installation Instructions THIS MANUAL IS FOR AUTHORIZED AND QUALIFIED INSTALLATION PERSONAL ONLY! Table of Contents General Information...3 CCS Overview...4 CCS Cabinet Dimensions...5

More information

MODEL RD-8 Self Contained MODEL RD-2

MODEL RD-8 Self Contained MODEL RD-2 MODEL RD-8 Self Contained REFRIGERATED SHOWCASE MODEL RD-2 REFRIGERATED SHOWCASE Document Part #: 1150285 Rev: I ECN: 55118 Rev. Date: 5-28-14 The RD-2 and RD-8 refrigerated display showcase units have

More information

Installation Instructions

Installation Instructions Installation Instructions Built-In Dishwasher If you have questions, call 800-GECARES or visit our website at: www.geappliances.com BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT

More information

HALLMARK INDUSTRIES INC. HALLMARK INDUSTRIES INC. Safety WARNING WARNING. Must reset the voltage! Shallow Well Jet Pumps

HALLMARK INDUSTRIES INC. HALLMARK INDUSTRIES INC. Safety WARNING WARNING. Must reset the voltage! Shallow Well Jet Pumps Safety Important Safety Instructions SAVE THESE INSTRUCTIONS - This manual contains important instructions that should be followed during installation, operation, and maintenance of the product. Save this

More information

CER-1 & CER-2 Site Requirements

CER-1 & CER-2 Site Requirements CER-1 & CER-2 Site Requirements 1 2 INTRODUCTION The following document outlines the space requirements, water supply, drain and electrical specifications required for the installation of the MEDIVATORS

More information

CER OPTIMA. Endoscope Reprocessing System CER-1 & CER-2 Site Requirements. Introduction. Space Requirements

CER OPTIMA. Endoscope Reprocessing System CER-1 & CER-2 Site Requirements. Introduction. Space Requirements CER OPTIMA Endoscope Reprocessing System CER-1 & CER-2 Site Requirements 1 1 2 Introduction The following document outlines the space requirements, water supply, drain and electrical specifications required

More information

J120 STEAM BOOSTER INSTALLATION, OPERATION, AND SERVICE MANUAL J120 STEAM BOOSTER. J120 Steam Booster Manual D

J120 STEAM BOOSTER INSTALLATION, OPERATION, AND SERVICE MANUAL J120 STEAM BOOSTER. J120 Steam Booster Manual D INSTALLATION, OPERATION, AND SERVICE MANUAL J120 STEAM BOOSTER J120 STEAM BOOSTER J120 Steam Booster Manual REVISION HISTORY Revision Letter Revision Date Made by Applicable ECNs Details A 10-27-04 CBW

More information

K-870-JA-AA K-872-JA-AA

K-870-JA-AA K-872-JA-AA Seawall 6 Whirlpool Baths: K-870-AA K-872-AA K-870-H-AA K-872-H-AA K-870-JA-AA K-872-JA-AA 111818-BA (1093) Copyright 1993 Kohler Co. IMPORTANT SAFETY INSTRUCTIONS ATTENTION INSTALLER: INSTRUCTIONS PERTAINING

More information

I NDUCTION C OOKTOP INSTALLATION INSTRUCTIONS

I NDUCTION C OOKTOP INSTALLATION INSTRUCTIONS I NDUCTION C OOKTOP INSTALLATION INSTRUCTIONS CONTACT INFORMATION Wolf Customer Service: 800-332-9513 Website: wolfappliance.com As you follow these instructions, you will notice WARNING and CAUTION symbols.

More information

WL380 QUICK START GUIDE

WL380 QUICK START GUIDE WL380 QUICK START GUIDE WARNING! Only trained and qualified technicians should attempt to install, maintain, or service Waterlogic equipment. Failure to follow all instructions in this manual could result

More information

Desiccant Dehumidifier

Desiccant Dehumidifier Since the 1950s Desiccant Dehumidifier Dry Spaces With NO Added Heat BMIL Technologies, LLC 4915 Arendell St., #313 Morehead City, NC 28557 PH 252-727-0994 FAX 252-727-0996 WWW.BMIL.COM Product Description

More information

INTELLILEVEL AUTOMATIC WATER LEVELING SYSTEM FOR POOL AND SPA

INTELLILEVEL AUTOMATIC WATER LEVELING SYSTEM FOR POOL AND SPA INTELLILEVEL AUTOMATIC WATER LEVELING SYSTEM FOR POOL AND SPA INSTALLATION AND USER S GUIDE IMPORTANT SAFET Y INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS 2 CUSTOMER SERVICE /

More information

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314)

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314) DRY AIR SYSTEMS, INC. 2655 Metro Boulevard Maryland Heights, Missouri 63043 (314) 344-1114 fax (314) 344-0677 HD SERIES DRIERS TABLE OF CONTENTS WHY AN AIR DRYER 3 WHAT IS A DESICCANT AIR DRYER 3 Desiccant

More information

Procenter Delivery Systems. [Includes: Delivery Units and Assistant s Units (All Styles)] (no serial numbers on Assistant s Units)

Procenter Delivery Systems. [Includes: Delivery Units and Assistant s Units (All Styles)] (no serial numbers on Assistant s Units) User Guide Procenter Delivery Systems [Includes: Delivery Units and Assistant s Units (All Styles)] Serial Number Locations DA259601i Procenter Delivery Unit Cabinet Mounted Units Assistant s Unit Compact

More information

Operator s Manual. Model G32-S Model G32-E Disinfection Soak Stations

Operator s Manual. Model G32-S Model G32-E Disinfection Soak Stations Model G32-S Model G32-E Disinfection Soak Stations Operator s Manual CIVCO Medical Solutions 102 First Street South Kalona, IA 52247 USA Tel: 1-800-445-6741 Fax: 1-877-329-2482 Website: WWW.CIVCO.COM Copyright

More information

Installation Instructions

Installation Instructions Installation Instructions Built-In Dishwasher If you have questions, call 800-944-9400(US),800-245-8352(Canada)or visit our website at: www.frigidaire.com BEFORE YOU BEGIN Read these instructions completely

More information

Horizontal/Side Discharge Condensing Units

Horizontal/Side Discharge Condensing Units INSTALLATION, OPERATION & MAINTENANCE MANUAL Horizontal/Side Discharge Condensing Units Models CMA12SD-0 CMA18SD-1 CMA24SD-1 CMA30SD-1 CMA36SD-1 CMA48SD-1 517.787.2100 www.marsdelivers.com Horizontal/Side

More information

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS INDEECO Circulation Heaters are designed to provide years of trouble free operation if properly installed and maintained. Please read and follow these instructions for installing and maintaining the heater.

More information

VSL II QUICK START GUIDE

VSL II QUICK START GUIDE This Quick Start Guide must be left with owner and should be hung on or adjacent to the boiler for reference. VSL II QUICK START GUIDE DIRECT-VENT SEALED COMBUSTION CONDENSING BOILER ~ GAS-FIRED BOILER

More information

INSTALLATION MANUAL GEO-BOOST GROUND LOOP HEAT EXCHANGER

INSTALLATION MANUAL GEO-BOOST GROUND LOOP HEAT EXCHANGER INSTALLATION MANUAL GEO-BOOST GROUND LOOP HEAT EXCHANGER Build Equinox support@buildequinox.com (773)-492-1893 Rev 2.0-05/10/2018 Build Equinox 2018 The Geo-Boost system consists of the Geo-Boost heat

More information

28 1/2"* 72.4 cm. (*28 1/2 " to include hinges.) 41 3/4" 106 cm. 27" 68.6 cm. 28 1/2"* 72.4 cm. (includes hinges.) 28 1/2"* 41 3/4" 106 cm

28 1/2* 72.4 cm. (*28 1/2  to include hinges.) 41 3/4 106 cm. 27 68.6 cm. 28 1/2* 72.4 cm. (includes hinges.) 28 1/2* 41 3/4 106 cm Commercial Single Load Dryers 28 1/2"* 72.4 cm PRODUCT DIMENSIONS (*28 1/2 " to include hinges.) 28 1/2"* 72.4 cm (*28 1/2 " to include hinges.) Models MDE/MDG21PD MDE/MDG21PS MDE/MDG21PR MDE/MDG21PN 43

More information

VENTILATION FAN / LED LIGHT

VENTILATION FAN / LED LIGHT VENTILATION FAN / LED LIGHT MODEL ITG50LED/ITG80LED TABLE OF CONTENTS Package Contents General Safety Information Preparation 4 Assembly Instructions 5 New Construction 5 Existing Construction 6 Grille

More information

MIRAI EXTRACTOR 100V DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THESE INSTRUCTIONS IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY

MIRAI EXTRACTOR 100V DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THESE INSTRUCTIONS IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY MIRAI EXTRACTOR 100V LOCATOR 1 2 3 4 MODE VAC 1 VAC 2 PUMP BYPASS INFORMATION & OPERATING INSTRUCTIONS DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THESE INSTRUCTIONS IMPROPER USE OF THE

More information

VACUUM OVEN. Model: VPX9-2. Installation and Operation Manual

VACUUM OVEN. Model: VPX9-2. Installation and Operation Manual VACUUM OVEN Model: VPX9-2 Installation and Operation Manual Sheldon Manufacturing, Inc. P.O. Box 627, 300 N 26 th Avenue, Cornelius, Oregon 97113 EMAIL: tech @ Shellab.com; www.shellab.com 1-800-322-4897

More information

Electrical Installation Instructions

Electrical Installation Instructions Steambath Generators Models: SM-2 and SM-5! Electrical Installation Instructions C US LISTED 995C WARNING: Elderly persons, pregnant women, or those suffering from heart disease, high blood pressure, diabetes,

More information

Sidel Combi-Combi Therm & CO2 Counter Installation Guide

Sidel Combi-Combi Therm & CO2 Counter Installation Guide Sidel Combi-Combi Therm & CO2 Counter Installation Guide Introduction Thank you for purchasing the Sidel Combi-Combi Therm & CO 2 Counter. The Combi-Combi Therm & CO 2 Counter control panel should be installed

More information

CAH SERIES INSTALLATION & MAINTENANCE MODELS CAH CAH

CAH SERIES INSTALLATION & MAINTENANCE MODELS CAH CAH CAH SERIES INSTALLATION & MAINTENANCE MODELS CAH 33-44-50 CAH 49-54-70 CAH VARIABLE SPEED AIR HANDLERS DIMENSIONS... 3 TECHNICAL SPECS... 4 INSTALLATION DON TS... 5 INSTALLATION DO S... 6 FREEZE STAT REQUIRED

More information

ECS Protector Dry SMART Vent - PSV-D (PSV-DE) Specifications

ECS Protector Dry SMART Vent - PSV-D (PSV-DE) Specifications ECS Protector - PSV-D (PSV-DE) Specifications For use under U.S. Patents 8,720,591, 9,144,700, 9,186,533 and 9,610,466 Stock Number : Service Pressure: System Connection: Electrical Connection: Temperature

More information

3/4 HP Model Trimmer Operating Instructions

3/4 HP Model Trimmer Operating Instructions 3/4 HP Model Trimmer Operating Instructions Whip Mix Corporation 361 Farmington Ave. P.O. Box 17183 Louisville, KY 40217-0183 USA 502-637-1451 800-626-5651 Fax 502-634-4512 www.whipmix.com Technical Specifications

More information

TECHNICAL SPECIFICATIONS - CW-80T-TWIN USA & MEXICO

TECHNICAL SPECIFICATIONS - CW-80T-TWIN USA & MEXICO GENERAL Climate Wizard coolers operate with a high ratio of energy efficiency and deliver cool fresh air at extremely low energy cost. The CW-80T-TWIN is characterized by having no additional moisture

More information

Dear Concessionaire,

Dear Concessionaire, Dear Concessionaire, In order to provide a comprehensive review & inspection of the Vendor application please review the following as guidance to a complete application and preparedness for inspection.

More information

Classic Twelve O clock Cabinet Installation Instructions

Classic Twelve O clock Cabinet Installation Instructions Classic Twelve O clock Cabinet Installation Instructions CF36 CF42 THIS MANUAL IS FOR AUTHORIZED AND QUALIFIED INSTALLATION PERSONEL ONLY! Table of Contents General Information... 3 CF36 Cabinet Overview...

More information

Rev B, 9/2/2009. Kodiak Chiller Overview

Rev B, 9/2/2009. Kodiak Chiller Overview 930-0001 Rev B, 9/2/2009 Kodiak Chiller Overview Presentation Outline Phone: 781-933-7300 Lytron Technical Support Contact Information 3 Introduction 4 Part I: Unpacking 5 Part II: Installation 7 Part

More information

PolyMax H2-24 Dutch Bucket System

PolyMax H2-24 Dutch Bucket System 11234 PolyMax H2-24 Dutch Bucket System *Actual system may differ. PolyMax Dutch Buckets Versatile PolyMax Dutch Buckets are ideal for both small- and large-scale hydroponic growing. 2017 FarmTek All Rights

More information

NOTE: If low flow check does not show high enough vacuum flow, repeat Steps 1-4, and adjust vacuum control knob to a higher vacuum flow setting. Effective scavenging is achieved if vacuum flow can be verified

More information

Aqua-Aire Sit-Bath System 6300 Installation / Assembly Instructions

Aqua-Aire Sit-Bath System 6300 Installation / Assembly Instructions Aqua-Aire Sit-Bath System 6300 Installation / Assembly Instructions PENNER PATIENT CARE, INC Box 523 / 102 Grant St. Aurora, NE 68818 350745 Rev F 02/23/11 1-866-PENNERS 1-866-736-6377 1-800-732-0717 E-mail

More information

Questions on Installation? Call: GECARES (US) or Visit our Web site at: (US) 4" DUCT CLAMPS (2) OR 4" SPRING CLAMPS (2)

Questions on Installation? Call: GECARES (US) or Visit our Web site at:  (US) 4 DUCT CLAMPS (2) OR 4 SPRING CLAMPS (2) Installation Instructions Questions on Installation? Call: 1-800-GECARES (US) or Visit our Web site at: www.geappliances.com (US) Electric Dryer 49 37 BEFORE YOU BEGIN Read these instructions completely

More information

Installation Instructions 30 French Door Built-in Wall Ovens

Installation Instructions 30 French Door Built-in Wall Ovens Installation Instructions 30 French Door Built-in Wall Ovens Questions? Call 1.800.GE.CARES (1.800.432.2737) or visit www.geappliances.com In Canada, call 1.800.561.3344 or visit www.geappliances.ca DESIGN

More information

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS Built-In Dishwasher Dishwashers Write the model and serial numbers here: Model # Serial # You can find them on the tub wall just inside the door or. the lower part of back. Installation Instructions DDW1802W

More information

Material Design for Central Chutes

Material Design for Central Chutes WASTE SOLUTIONS Why Central Chutes? In the rapidly growing and highly competitive world of today; high-rise buildings, large apartments serving commercial and residential, and construction buildings have

More information

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½" bit

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½ bit Installation Parts and Tools Parts not Provided Electrical cable Water supply tube Fittings for tube Coupler Teflon tape Air gap Wire nuts for 6-gauge wiring Hose clamp ⅞" UL approved strain relief Electrical

More information

SE Series Modular Electric Stone-Hearth Deck Oven INSTALLATION & OPERATION MANUAL LBC BAKERY EQUIPMENT, INC st Ave NE Tulalip, WA 98271, USA

SE Series Modular Electric Stone-Hearth Deck Oven INSTALLATION & OPERATION MANUAL LBC BAKERY EQUIPMENT, INC st Ave NE Tulalip, WA 98271, USA SE Series Modular Electric Stone-Hearth Deck Oven INSTALLATION & OPERATION MANUAL LBC BAKERY EQUIPMENT, INC. 6026 31 st Ave NE Tulalip, WA 98271, USA Toll Free: 888-722-5686 Email: sales@lbcbakery.com

More information

Gerber Innovations M Series Laser. Site Preparation & Installation Manual

Gerber Innovations M Series Laser. Site Preparation & Installation Manual Gerber Innovations M Series Laser Site Preparation & Installation Manual Copyright Notice COPYRIGHT 2011 Gerber Innovations, Inc. All Rights Reserved. This document may not be reproduced by any means,

More information

MODELS LFP4218/LFP6018 TOP VENT GAS FIREPLACE

MODELS LFP4218/LFP6018 TOP VENT GAS FIREPLACE MODELS LFP4218/LFP6018 TOP VENT GAS FIREPLACE PFS APPROVED FOR NATURAL GAS OR PROPANE GAS Z21.50-2014 If your plans do not allow for the venting system as outlined previously in the installing chimney/vent

More information

VENTILATION FAN WITH LED LIGHT AND HEATER MODEL RAD110LED

VENTILATION FAN WITH LED LIGHT AND HEATER MODEL RAD110LED VENTILATION FAN WITH LED LIGHT AND HEATER MODEL RAD110LED TABLE OF CONTENTS Package Contents Important Instructions Preparation Assembly Instructions Wiring Instructions Operating Instructions Care and

More information

Installation Instructions

Installation Instructions Installation Instructions KFN 9855 ide en - CA Installation, repair and maintenance work should be performed by a Miele authorized service technician in accordance with national and local safety regulations

More information

Installation Instructions

Installation Instructions Installation Instructions 6 KW and 11.5KW Basic Circulation Water Heater and Pump Application: The Basic Circulation Water Heater has been in use for nearly 50 years, and it is the most prevalent model

More information

Congratulations! You've just purchased a new Marey ECO tankless water heater and will soon begin to enjoy the benefits of going tankless.

Congratulations! You've just purchased a new Marey ECO tankless water heater and will soon begin to enjoy the benefits of going tankless. Congratulations! You've just purchased a new Marey ECO tankless water heater and will soon begin to enjoy the benefits of going tankless. Please take the time to thoroughly read and understand this safety

More information

LC Series - Light Commercial Pump Station Installation and Operation Manual

LC Series - Light Commercial Pump Station Installation and Operation Manual LC Series - Light Commercial Pump Station Installation and Operation Manual Please keep this manual with the pump station Content Rain Bird LC Series Overview... Safety Instruction... Operation... 3 Pump

More information

INSTALLATION INSTRUCTIONS FOR MULTI-UNIT RESIDENTIAL APPLICATIONS INSTALLATION INSTRUCTIONS ARE PER UNIT MODELS: RS-502C, RS-503C, RS-702C, RS-703C

INSTALLATION INSTRUCTIONS FOR MULTI-UNIT RESIDENTIAL APPLICATIONS INSTALLATION INSTRUCTIONS ARE PER UNIT MODELS: RS-502C, RS-503C, RS-702C, RS-703C ROMA STEAM BATH 16802 BARKER SPRINGS DRIVE HOUSTON, TEXAS 77084 (281) 578-9945 1-800-657-0656 RES-M-RS INSTALLATION INSTRUCTIONS FOR MULTI-UNIT RESIDENTIAL APPLICATIONS INSTALLATION INSTRUCTIONS ARE PER

More information

C O D E S & A M M E N D M E N T S

C O D E S & A M M E N D M E N T S SEVIER COUNTY UTILITY DISTRICT SEPTEMBER 2, 2014 Sevier County Utility District has adopted the 2009 International Fuel Gas Code for gas inspections. The following pages contain frequently used codes and

More information

WM-450-PT WM-900-PT Commercial Wall Mounted Reverse Osmosis

WM-450-PT WM-900-PT Commercial Wall Mounted Reverse Osmosis WM-450-PT WM-900-PT Commercial Wall Mounted Reverse Osmosis Installation And Service Manual Watts Pure Water 1725 W. Williams Dr. C-20., Phoenix, Arizona 85027 Phone: 888-774-7405 Fax: 602-588-0356 www.wattspurewater.com

More information

Modular Panel System for Radiant Floor Heating.

Modular Panel System for Radiant Floor Heating. Modular Panel System for Radiant Floor Heating Comprehensive technology, energy-saving performance, plus compact professional design make HydroShark s modular panel system an easy install and a great value

More information

Cool IR. Model C104 - Cooling System. Instruction Manual

Cool IR. Model C104 - Cooling System. Instruction Manual Cool IR Model C104 - Cooling System Instruction Manual February 26, 2015 Research, Inc. USA Ph: 952.949-9009 Fax: 952.949-9559 tsdsales@researchinc.com www.researchinc.com Table of Contents List of Figures...

More information

Installation Instructions Built-In Dishwasher

Installation Instructions Built-In Dishwasher GE Consumer & Industrial Appliances Installation Instructions Built-In Dishwasher If you have questions, call 800.GE.CARES (800.432.2737) or visit our website at: www.ge.com BEFORE YOU BEGIN Read these

More information