Rytons Boiler, Stove and Fire Ventilators

Size: px
Start display at page:

Download "Rytons Boiler, Stove and Fire Ventilators"

Transcription

1 CI/SfB reference by RIBA SfB Agency (21.9 Xn6 (L2 Wall Issue 20 January 2015 Rytons Boiler, Stove and Fire Ventilators Full size guides, technical information, images and installation videos available at: Introducing Rytons New Mini AirCore For more information call: Join us at: facebook.com/rytons See page 6 for details 1

2 , Services Choice and and Quality Free Delivery Free delivery is available on orders of just 50 nett to any address on the UK mainland including sites. Next Day Delivery Fast delivery means shorter leads times with orders confirmed before 3pm dispatched the same day and 99.14% delivered next working day at no extra charge. Orders to rthern Ireland and the Republic of Ireland are normally delivered in 2-3 working days. Happy to Help Please feel free to call us on or us at with your quotes, questions or queries. Our offices are open 8:30am 5:00pm weekdays and we are here to help. Colour Matching Service We are able to manufacture many of our ventilators in alternative colours. You can choose from our standard colour palette or provide us a RAL number. For further information contact our sales office on Environmental Policy Where practicable, and where the product quality can be maintained, our plastic products are made from or incorporate recycled material. Where possible product packaging is made of degradable recycled cardboard and the minimum packaging possible is used. To avoid excessive product literature, information is available in a variety of paper free formats. Further information is available at Verifiable Testing and Independent Rytons has the largest range of BBA approved ventilators on the market. BBA approval is third party evaluation and accreditation, and approved products are accepted by building control, architects, engineers and surveyors, and by the NHBC. It s your assurance that our products meet the Standards and will last something not offered by all manufacturers. HETAS is the official body for approving solid fuel domestic heating appliances. Rytons ventilators are the only products on the market with HETAS approval and the only ventilators recommended by HETAS to their registered engineers. The Building Research Establishment Ltd is an independent testing authority. BRE Acoustics measurements were conducted using procedures accredited by UKAS. NBS Plus Rytons technical specifications are listed on NBS Plus, part of the NBS industry standard specification software used by architects, building surveyors and other construction industry professionals. NBS Plus data is also available to paste straight into your project specification, free of charge, at Key Please recycle cardboard packaging, product guides and printouts. If you are unable to use excess products on another project they may be recycled where facilities exist. Flame retardant Fire retardant 2 part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying, recording or information storage or retrieval system, without either the prior permission in writing from the publisher or a licence, permitting restricted copying. Architects or similar are permitted to reproduce appropriate illustrations on plans and documents only. All Rytons products are neither hazardous to health nor harmful to the environment when used correctly. Rytons reserve the right to improve specifications from time to time without prior notice. All information is given in good faith and to the best of our knowledge is true and accurate. Since delivery dates, the use of products and control of the labour involved is outside our control, no warranty is given nor should Rytons representatives or agents imply any warranty. Customers should also satisfy themselves that the products are suitable for the intended purpose. Calls to and from Rytons are recorded to help us maintain and improve our service. Rytons products are protected under section 213 of the Copyright, Designs and Patents Act Registered Trademark of Rytons Building Products Ltd. All trademarks and trade names used in this brochure are the property of Rytons Building Products Ltd. Copyright Building Products Ltd Any communication regarding the above should be directed to Rytons Building Products Ltd, Design House, Kettering Business Park, Kettering, NN15 6NL.

3 Contents Product Name Product Code Sound Reduction db D n,e,w Page Rytons Mini AirCore NEW AC3LP 31.68cm² Unsilenced 6 Rytons Super Acoustic AirCore AAC125LP 74cm² 44 db 7 Rytons Cowled Super Acoustic AirCore AAC125LPCWL 72cm² 45 db 7 Rytons High Rise Super Acoustic AirCore AAH125LP 66cm² 44 db 7 Rytons AirCore AC10LP 104cm² Unsilenced 8 Rytons Cowled AirCore AC10LPCWL 111cm² Unsilenced 8 Rytons Baffled AirCore AC7LP 79cm² Unsilenced 8 Rytons Cowled Baffled AirCore AC7LPCWL 81cm² Unsilenced 8 Rytons High Rise AirCore ACH75LP 68cm² Unsilenced 8 Rytons '9x3' Acoustic AirLiner Set with Flush Louvre Ventilator TAL4SET 58cm² 38 db 9 Rytons '9x3' Cowled Acoustic AirLiner Set with Flush Louvre Ventilator TAL4CWL 58cm² 39 db 9 Rytons '9x3' Ventilation Set with Flush Louvre Ventilator TCL8 94cm² Unsilenced 9 Rytons '9x3' Cowled Ventilation Set with Flush Louvre Ventilator TCL8CWL 91cm² Unsilenced 9 Rytons '9x6' Acoustic AirLiner Set with Flush Louvre Ventilator TALSET 63cm² 39 db 10 Rytons '9x6' Cowled Acoustic AirLiner Set with Flush Louvre Ventilator TALCWL 55cm² 42 db 10 Rytons '9x6' Ventilation Set with Flush Louvre Ventilator TCL18 175cm² Unsilenced 10 Rytons '9x6' Cowled Ventilation Set with Flush Louvre Ventilator TCL18CWL 172cm² Unsilenced 10 Rytons '9x9' Acoustic AirLiner Set with Louvre Ventilator TAL9SET 131cm² 38 db 11 Rytons '9x9' Cowled Acoustic AirLiner Set with Louvre Ventilator TAL9CWL 122cm² 40 db 11 Rytons '9x9' Ventilation Set with Louvre Ventilator TCL20 265cm² Unsilenced 11 Rytons '9x9' Cowled Ventilation Set with Louvre Ventilator TCL20CWL 240cm² Unsilenced 11 Rytons Direct Ventilation Kits Various N/A N/A 12 Rytons Venting Kits Various N/A N/A 13 Rytons Floor Ventilators FV10 110cm² * N/A 14 Rytons Intumescent RytBlocks Various Various N/A 14 Rytons Handy Access Panels Various N/A N/A 15 What is a D n,e,w sound reduction figure? A D n,e,w figure reflects testing at every frequency and it is the only result recommended by the BRE for products such as vents. As there is no industry standard for presenting acoustic test results, beware of any manufacturer who quotes an unspecified db figure. An unspecified figure may simply be the highest db achieved at an individual frequency and may not bear any relation to your circumstances or to the type of noise you are aiming to reduce. Only a D n,e,w figure gives you peace of mind that the result reflects the true performance of the product. * Free 3

4 A step by step guide to calculating the ventilation requirements of gas appliances Quick reference extracts from the Building Regulations Part J. For detailed guidance with examples please refer to the full document. Appliance type Open-flued gas burning appliance with a rated input up to 70kW (net Room-sealed gas burning appliance with a rated input up to 70kW (net Decorative fuel effect gas appliance of heat input not exceeding 20kW 10,000mm² min. Also refer to manufacturers instructions Appliance in a room or space House built in or after 2008 House built before 2008* Flueless space heater not in a hallway, landing or other internal space Flueless space heater in an internal space such as a hallway or landing Provide 500mm² per kw Input (net Open-flued appliance in an appliance compartment ventilated via an adjoining room or space Open-flued appliance in an appliance compartment ventilated direct to outside Provide 500mm² per kw Input above 7kW (net Refer to Building Regulations Part J Max appliance rated heat input 0.045kW (net per m³ volume of room 10,000mm² PLUS 5,500mm² per kw input (net in excess of 2.7kW (net permanently open vent is needed if the room or space has a door direct to outside Can I use a vent that gives a free area instead of equivalent free area? Max appliance rated heat input 0.090kW (net per m³ volume of internal space 10,000mm² PLUS 2,750mm² per kw input (net in excess of 5.4kW (net Can I use a closeable grille on the inside? Can the vent incorporate a flymesh? Is it safe to make my own vent using a tube with louvres either side? See our range of through-wall vents for gas appliances on pages 6-11 and floor vents on page 14. * If the house has been extensively upgraded for increased airtightness provide 500mm² per kw Input (net. Refer to Appendix F of Part J for details of measures that constitute significantly improving airtightness. BS :2005 4

5 A step by step guide to calculating the ventilation requirements of solid fuel appliances Extracts from the Building Regulations Part J. Information applies only to stoves, cookers and boilers burning solid fuel (including solid biofuel with a rated output up to 50kW. START When was the house built? In or after 2008 Before 2008 Has the house had extensive upgrades to make it more airtight* Yes Is the appliance with a flue draught stabiliser? Yes Is the appliance with a flue draught stabiliser? Yes Provide 850mm² per kw of appliance rated output Provide 550mm² per kw of appliance rated output Is it safe to make my own vent using a tube with louvres either side? Provide 300mm² per kw for the first 5kW PLUS 850mm² per kw for the balance of appliance rated output Provide 550mm² per kw of appliance rated output above 5kW Can I use a closeable grille on the inside if I promise to open it when the stove is on? Can I use a vent that gives a free area instead of equivalent free area? Can the vent incorporate a flymesh? Where can I find HETAS Approved vents with verifiable equivalent free areas? Rytons is proud to be the only manufacturer to have HETAS Approved vents. You will find our range of approved products on pages * Refer to Appendix F of the Building Regulations Part J for measures that constitute significantly improving airtightness. 5

6 New New New Rytons Mini AirCore Answering industry demand for a small vent for small appliances, we are pleased to announce that there is a new addition to the AirCore family Introducing Rytons Mini AirCore. A new 3" dia. core ventilator specifically designed for low kilowatt stoves and fires. Featuring an internal grille barely bigger than a light switch, this perfectly proportioned set is our most discreet combustion air vent. The grille s front panel may also be painted or wallpapered to blend in with the room s décor for an appearance that s virtually unnoticeable. For maximum comfort the internal grille is in our popular panel design. The venting outlets are hidden from view behind a front plate which allows air to be dispersed evenly, significantly reducing draughts. Industry compliant, this Mini AirCore has a verifiable equivalent area to comply with Part J and is HETAS approved for use with solid fuel appliances. It will also satisfy the regulations for many other small appliances, including gas. Helps maintain a pleasant environment whether or not the stove is in use. Rytons AC3LP Rytons Mini AirCore NEW Combustion air vent for low kilowatt stoves and fires. Easily retro- through a 78mm core drilled hole. Virtually unnoticeable mini internal panel. External grille U.V. stabilised. Screws provided for securing the internal panel. 158mm L x 98mm H 77mm Dia. x Mini 110mm L x 110mm H 3168mm² 31.68cm² Mini decorated Rytons Mini AirCore (AC3LP - Stove Output Compatibility Chart Stove without flue draught stabiliser Stove with flue draught stabiliser House built prior to 2008* Up to 10kW (2750mm² requirement Up to 6kW (2350mm² requirement House built in or after 2008 Up to 5kW (2750mm² requirement Up to 3kW (2550mm² requirement * If a dwelling has been upgraded to make it more airtight use post 2008 calculations. Refer to Appendix F of the Building Regulations Part J for measures that constitute significantly improving airtightness. 6

7 Rytons Super Acoustic AirCore Ventilators Rytons AAC125LP Rytons Super Acoustic AirCore (44 db D n,e,w Easily retro- through a 127mm core drilled hole. Acoustic lining reduces sound by 44 db D n,e,w. External grille U.V. stabilised. Fixing screws for panel provided in all sets. 166mm L x 160mm H 127mm Dia. x 172mm L x 172mm H 7400mm² 74cm² decorated It is a common experience that noise is unpleasant and affects the quality of life. It disturbs and interferes with activities of the individual, including concentration, communication, relaxation and sleep. World Health Organization Rytons AAC125LPCWL Rytons Cowled Super Acoustic AirCore (45 db D n,e,w Easily retro- through a 127mm core drilled hole. Acoustic lining reduces sound by 45 db D n,e,w. External cowl reduces light and draughts. External cowl and grille U.V. stabilised. 217mm L x 210mm H x 93mm D 127mm Dia. x 7200mm² 72cm² Cowl and decorated To reduce noise transfer through background room ventilators we recommend choosing an acoustic option wherever possible. Being able to enjoy your home free from a stressor such as noise could provide a greater sense of wellbeing plus health benefits. Rytons AAH125LP Rytons High Rise Super Acoustic AirCore (44 db D n,e,w Easily retro- through a 127mm core drilled hole. Fitted from the inside for high rise constructions. Acoustic lining reduces sound by 44 db D n,e,w. External grille U.V. stabilised. 127mm Dia. x 172mm L x 172mm H 6600mm² 66cm² decorated 7

8 Rytons Unsilenced AirCore Ventilators Rytons AC10LP Rytons AirCore Easily retro- through a 127mm core drilled hole. Provides over 100cm² equivalent area. External grille U.V. stabilised. Fixing screws for panel provided in all sets. 166mm L x 160mm H 127mm Dia. x 172mm L x 172mm H 10400mm² 104cm² decorated Rytons AC10LPCWL Rytons Cowled AirCore Easily retro- through a 127mm core drilled hole. Provides over 110cm² equivalent area. External cowl reduces light and draughts. External cowl and grille U.V. stabilised. Fixing screws for panel provided in all sets. 217mm L x 210mm H x 93mm D 127mm Dia. x 11100mm² 111cm² Cowl and decorated Rytons AC7LP Rytons Baffled AirCore Easily retro- through a 127mm core drilled hole. Internal baffles reduce light and draughts. External grille U.V. stabilised. Fixing screws for panel provided in all sets. 166mm L x 160mm H 127mm Dia. x 172mm L x 172mm H 7900mm² 79cm² decorated Rytons AC7LPCWL Rytons Cowled Baffled AirCore Easily retro- through a 127mm core drilled hole. Cowl and internal baffles reduce light and draughts. External cowl and grille U.V. stabilised. Fixing screws for panel provided in all sets. 217mm L x 210mm H x 93mm D 127mm Dia. x 8100mm² 81cm² Cowl and decorated Rytons ACH75LP Rytons High Rise AirCore Easily retro- through a 127mm core drilled hole. Fitted from the inside for high rise constructions. Internal baffles reduce light and draughts. External grille U.V. stabilised. Fixing screws for panel provided in all sets. 127mm Dia. x 172mm L x 172mm H 6800mm² 68cm² decorated 8

9 Rytons Acoustic Ventilation Sets '9x3' Rytons TAL4SET Rytons '9x3' Acoustic AirLiner Set with Flush Louvre Ventilator (38 db D n,e,w Acoustic lining reduces sound by 38 db D n,e,w. Internal baffle reduces light and draughts. Finished with a fixed open flush fitting louvre vent. Internal and external grilles U.V. stabilised mm L with air brick 270mm L x 97mm H 5800mm² 58cm², grey, blue/black, black, brown Rytons TAL4CWL Rytons '9x3' Cowled Acoustic AirLiner Set with Flush Louvre Ventilator (39 db D n,e,w Acoustic lining reduces sound by 39 db D n,e,w. Cowl and internal baffle reduces light and draughts. Finished with a fixed open flush fitting louvre vent. Cowl and grilles U.V. stabilised. 255mm L x 96mm H x 44mm D mm L with air brick 5800mm² 58cm² Cowl & buff/sand One in three individuals is annoyed during the daytime and one in five has disturbed sleep at night because of traffic noise. World Health Organization Rytons Unsilenced Ventilation Sets '9x3' Rytons TCL8 Rytons '9x3' Ventilation Set with Flush Louvre Ventilator Internal baffle reduces light and draughts. Finished with a fixed open flush fitting louvre vent. Internal and external grilles U.V. stabilised mm L with air brick 270mm L x 97mm H 9400mm² 94cm², grey, blue/black, black, brown Rytons TCL8CWL Rytons '9x3' Cowled Ventilation Set with Flush Louvre Ventilator Cowl and internal baffle reduces light and draughts. Finished with a fixed open flush fitting louvre vent. Cowl and grilles U.V. stabilised. 255mm L x 96mm H x 44mm D mm L with air brick 9100mm² 91cm² Cowl & buff/sand 9

10 Rytons Acoustic Ventilation Sets '9x6' Rytons TALSET Rytons '9x6' Acoustic AirLiner Set with Flush Louvre Ventilator (39 db D n,e,w Acoustic lining reduces sound by 38 db D n,e,w. Internal baffles reduce light and draughts. Finished with a fixed open flush fitting louvre vent. Internal and external grilles U.V. stabilised mm L with air bricks 264mm L x 166mm H 6300mm² 63cm², grey, blue/black, black, brown Rytons TALCWL Rytons '9x6' Cowled Acoustic AirLiner Set with Flush Louvre Ventilator (42 db D n,e,w Acoustic lining reduces sound by 42 db D n,e,w. Cowl and internal baffles reduce light and draughts. Finished with a fixed open flush fitting louvre vent. Cowl and grilles U.V. stabilised. 255mm L x 154mm H x 74mm D mm L with air bricks 5500mm² 55cm² Cowl & Both road traffic noise and aircraft noise increase the risk of high blood pressure. World Health Organization Rytons Unsilenced Ventilation Sets '9x6' Rytons TCL18 Rytons '9x6' Ventilation Set with Flush Louvre Ventilator Provides over 170cm² equivalent area. Internal baffles reduce light and draughts. Finished with a fixed open flush fitting louvre vent. Internal and external grilles U.V. stabilised mm L with air bricks 264mm L x 166mm H 17500mm² 175cm², grey, blue/black, black, brown Rytons TCL18CWL Rytons '9x6' Cowled Ventilation Set with Flush Louvre Ventilator Provides over 170cm² equivalent area. Cowl and internal baffles reduce light and draughts. Finished with a fixed open flush fitting louvre vent. Cowl and grilles U.V. stabilised. 255mm L x 154mm H x 74mm D mm L with air bricks 17200mm² 172cm² Cowl & 10

11 Rytons Acoustic Ventilation Sets '9x9' Rytons TAL9SET Rytons '9x9' Acoustic AirLiner Set with Louvre Ventilator (38 db D n,e,w Acoustic lining reduces sound by 38 db D n,e,w. Provides over 130cm² equivalent area. Internal baffles reduce light and draughts. Finished with a fixed open louvre vent internally. Internal and external grilles U.V. stabilised mm L with air bricks 271mm L x 247mm H 13100mm² 131cm², grey, blue/black, black, brown Rytons TAL9CWL Rytons '9x9' Cowled Acoustic AirLiner Set with Louvre Ventilator (40 db D n,e,w Acoustic panels reduce sound by 40 db D n,e,w. Provides over 120cm² equivalent area. Cowl and internal baffles reduce light and draughts. Finished with a fixed open louvre vent internally. Cowl and grilles U.V. stabilised. 274mm L x 235mm H x 103mm D mm L with air bricks 12200mm² 122cm² Cowl & Road traffic noise has been shown to increase the risk of ischaemic heart disease. World Health Organization Rytons Unsilenced Ventilation Sets '9x9' Rytons TCL20 Rytons '9x9' Ventilation Set with Louvre Ventilator Provides over 260cm² equivalent area. Internal baffles reduce light and draughts. Finished with a fixed open louvre vent internally. Internal and external grilles U.V. stabilised mm L with air bricks 271mm L x 247mm H 26500mm² 265cm², grey, blue/black, black, brown Rytons TCL20CWL Rytons '9x9' Cowled Ventilation Set with Louvre Ventilator Provides over 200cm² equivalent area. Cowl and internal baffles reduce light and draughts. Finished with a fixed open louvre vent internally. Cowl and grilles U.V. stabilised. 274mm L x 235mm H x 103mm D mm L with air bricks 24000mm² 240cm² Cowl & 11

12 A step by step guide to Direct Ventilation Kits Direct ventilation to a stove with a ventilation attachment allows combustion air from the outside straight into the appliance. We have a wide range of Direct Ventilation Kits available from stock, and are able to make many more bespoke kits to your requirements. Follow our four simple steps below to create the right kit for your stove. te: Direct ventilation isn't suitable for all stoves. Always refer to the stove manufacturer's instructions regarding venting requirements. Step 1 Select the correct size semi-rigid aluminium ducting for your stove attachment Standard sizes available from stock: 100mm Dia. x 1.5m L (3m L to order 125mm Dia. x 1.5m L (3m L to order 150mm Dia. x 1.5m L (3m L to order We can also take special orders for any non-standard size within a range of 63mm to 500mm Dia. Step 2 Choose an external grille from our range of plastic and metal vents Plastic louvre grille Available in a range of colours Stainless Steel Cowled Grille To suit 100mm, 125mm and 150mm ducting Stainless Steel Meshed Grille To suit 100mm, 125mm and 150mm ducting Step 3 Don't forget! Jubilee Clips To suit 100mm, 125mm and 150mm ducting Standard requirement two clips per kit for a secure fit Step 4 With a note of your requirements call our sales office on for a price or to place an order Questions & Answers What is the operating temperature of the semi-rigid ducting? Up to 300 C. What is the longest length of semi-rigid ducting available? 3m to order. Connectors available. How long can a venting run be? Keep the run as short as possible and consider fire breaks through multiple rooms. Can ducting include bends? Keep the run as straight as possible and check with your stove manufacturer. Does direct venting replace room venting? Ask your stove manufacturer. If in doubt vent the room and the stove. 12

13 A step by step guide to Venting Kits Rytons Venting Kits are simple extract air vents for tumble dryers and extractor fans. We have a variety of kits available from stock to suit 100mm, 125mm and 150mm Dia. attachments, and we are able to make many more bespoke kits to your requirements. The following chart will guide you through the options available allowing you to create the right kit for your appliance. What size attachment does the appliance have? 100mm Dia. 125mm Dia. 150mm Dia. Choose a length of PVC flexible ducting 1m, 2m, 3m, 6m, 15m, 45m L 3m, 6m L 3m, 6m, 15m L Choose an external grille from our range of louvre vents, cowled grilles and gravity grilles in plastic and metal With a note of your requirements call our sales office on for a price or to place an order All kits supplied with an internal make good plate and zip ties Questions & Answers What is the operating temperature of the flexible ducting? From -5 C to 60 C. Will the ducting require cutting to length? For best performance pull the flexible ducting as taut as possible during installation and cut away any excess. Is there an alternative to circular ducting? We have an extensive range of flat channel ducting and connectors available for situations where circular is not suitable, see our RytDuct guide or call our sales office for details. 13

14 Rytons Floor Ventilators and Intumescent RytBlocks Free Rytons FV10BRASS Rytons Floor Ventilator with Brass Louvre Room ventilator. Utilises air from a ventilated sub-floor void. Mirror polished solid brass louvre. Inverted louvres provide a flush finish. Brass coloured screws included. 267mm L x 95mm H x 125mm D 11000mm² 110cm² Polished brass Sleeve: Black Rytons FV10CHROME Rytons Floor Ventilator with Chromed Louvre Room ventilator. Utilises air from a ventilated sub-floor void. Chrome plated solid brass louvre. Inverted louvres provide a flush finish. Chrome coloured screws included. 267mm L x 95mm H x 125mm D 11000mm² 110cm² Chrome Sleeve: Black Rytons ACFIRE Rytons 125mm AirCore Intumescent RytBlock Heavy duty intumescent grille for walls and ducts. In the event of a fire slats fuse together and seal within 2 minutes. Gives 3 hours protection preventing the passage of smoke and gases. Temperature increase insulated for 22 minutes. May be used in high humidity. Compatible with Rytons 125mm Dia. AirCores. 118mm Dia. x 43mm D 5150mm² 51.5cm² Steel grey Rytons TL8FIRE Rytons '9x3' Intumescent RytBlock Heavy duty intumescent grille for walls and ducts. In the event of a fire slats fuse together and seal within 2 minutes. Gives 3 hours protection preventing the passage of smoke and gases. Temperature increase insulated for 22 minutes. May be used in high humidity. Compatible with Rytons '9x3' AirLiners. 206mm L x 58mm H x 44mm D 5330mm² 53.3cm² Steel grey Rytons TL18FIRE Rytons '9x6' Intumescent RytBlock Heavy duty intumescent grille for walls and ducts. In the event of a fire slats fuse together and seal within 2 minutes. Gives 3 hours protection preventing the passage of smoke and gases. Temperature increase insulated for 22 minutes. May be used in high humidity. Compatible with Rytons '9x6' AirLiners. 206mm L x 124mm H x 44mm D 13390mm² 133.9cm² Steel grey 14

15 Rytons Handy Access Panels Rytons HAP Rytons Handy Access Panel (150mm x 230mm Handy panel allowing access to plumbing and electrical services for inspection and maintenance. Fit in a vertical or horizontal position. Flush faced with discreet slot openings. Strong catch prevents the door popping open. Suitable for use in walls and ceilings. U.V. stabilised to slow down the effects of sunlight. Structural opening: 155mm x 235mm Frame size: 195mm x 272mm Clear opening: 142mm x 216mm Internal frame depth: 16mm painted Rytons HAP Rytons Handy Access Panel (200mm x 200mm Handy panel allowing access to plumbing and electrical services for inspection and maintenance. Fit in a vertical or horizontal position. Flush faced with discreet slot openings. Strong catch prevents the door popping open. Suitable for use in walls and ceilings. U.V. stabilised to slow down the effects of sunlight. Structural opening: 205mm x 205mm Frame size: 248mm x 248mm Clear opening: 191mm x 194mm Internal frame depth: 16mm painted Rytons HAP Rytons Handy Access Panel (300mm x 300mm Handy panel allowing access to plumbing and electrical services for inspection and maintenance. Fit in a vertical or horizontal position. Flush faced with discreet slot openings. Strong catch prevents the door popping open. Suitable for use in walls and ceilings. U.V. stabilised to slow down the effects of sunlight. Structural opening: 305mm x 305mm Frame size: 345mm x 345mm Clear opening: 293mm x 294mm Internal frame depth: 16mm painted Can't find the access panel you require? Special order access panels are available in the following sizes: 100mm x 150mm 150mm x 150mm 350mm x 350mm 450mm x 450mm 560mm x 560mm Call and ask our sales office for details (box quantities may apply. 15

16 Rytons Product Guides, Technical Information and Dimensional Drawings Rytons Background Ventilators Rytons Boiler, Stove and Fire Ventilators Rytons Cavity and Underfloor Ventilators Rytons DamRyt Flood & Render Protection Rytons Roof Ventilators Rytons Louvre and Hit & Miss Ventilators Rytons RytDuct and RytHose Ranges Product Guides are available to download free of charge at Free Downloads Download Rytons Product Guides and technical information free of charge at Alternatively, information is available by or post, contact us on or with your request. Dimensional Drawings Dimensional drawings are available for a large number of our products. For a current drawing a request to admin@rytons.com. Contact Us Please feel free to call or us with your quotes, questions or queries. Rytons Building Products Ltd Design House Kettering Business Park Kettering NN15 6NL T: F: E: admin@rytons.com GB Manufacturer 16

Rytons Boiler, Stove & Fire Ventilators

Rytons Boiler, Stove & Fire Ventilators CI/SfB reference by RIBA SfB Agency (21.9) Xn6 (L2) Wall April 2015 Rytons Boiler, Stove & Fire Ventilators 00441536 511874 www.vents.co.uk Contents General Guidance Product Name Product Sound db D n,e,w

More information

Rytons Boiler, Stove & Fire Ventilators

Rytons Boiler, Stove & Fire Ventilators CI/SfB reference by RIBA SfB Agency (21.9) Xn6 (L2) Wall April 2015 Rytons Boiler, Stove & Fire Ventilators 01536 511874 www.vents.co.uk Contents General Guidance Product Name Product Sound db D n,e,w

More information

Rytons Louvre and Hit & Miss Ventilators

Rytons Louvre and Hit & Miss Ventilators CI/SfB reference by RIBA SfB Agency (21.9) Xn6 (L2) Wall April 2015 Rytons Louvre and Hit & Miss Ventilators Technical information available online at: www.vents.co.uk Alternatively call us on 01536 511874

More information

Rytons Louvre and Hit & Miss Ventilators

Rytons Louvre and Hit & Miss Ventilators CI/SfB reference by RIBA SfB Agency (21.9) Xn6 (L2) Wall November 2017 Rytons Louvre and Hit & Miss Ventilators Technical information available from our website at: www.vents.co.uk Alternatively, call

More information

Rytons Louvre and Hit & Miss Ventilators

Rytons Louvre and Hit & Miss Ventilators CI/SfB reference by RIBA SfB Agency (21.9) Xn6 (L2) Wall January 2018 Rytons Louvre and Hit & Miss Ventilators Technical information available from our website at: www.vents.co.uk Alternatively, call us

More information

Permanent Ventilators (for the Supply of Combustion Air)

Permanent Ventilators (for the Supply of Combustion Air) (for the Supply of Combustion Air Essentials (for Supply of Combustion Air All heating appliances that produce heat from the combustion of carbon based fuels such as gas, oil and solid fuels including

More information

Introduction ... The HETAS Guide. to Approved Solid Fuel, Wood and Biomass Products and Services. List no. 24 HETAS 2018

Introduction ... The HETAS Guide. to Approved Solid Fuel, Wood and Biomass Products and Services. List no. 24 HETAS 2018 Introduction The HETAS Guide... to Approved Solid Fuel, Wood and Biomass Products and Services List no. 24 2018 i Part 4 - Installation, Safety & Maintenance Permanent Ventilators (for Supply of Combustion

More information

Rytons RytDuct. Flat Channel Ducting and Components. 100mm, 125mm and 150mm Ranges Available. Issue 13 July 2012

Rytons RytDuct. Flat Channel Ducting and Components. 100mm, 125mm and 150mm Ranges Available. Issue 13 July 2012 CI/SfB reference by RIBA SfB Agency (21.9) Xn6 (L2) Wall Issue 13 July 2012 Rytons RytDuct Flat Channel Ducting and Components 100mm, 125mm and 150mm Ranges Available Full size guides, technical data sheets,

More information

A6VS VENTILATION STANDARDS

A6VS VENTILATION STANDARDS A6VS VENTILATION STANDARDS First Name: Last Name: Email: A6VS - Ventilation Standards Assessment ID : A6VS Instructions: Select a single answer from all questions 1. Provision of Ventilation has to be

More information

Introduction. Products conforming with a European Council Directive. CE marked construction products. Other regulations

Introduction. Products conforming with a European Council Directive. CE marked construction products. Other regulations Introduction This Technical Booklet has been prepared by the Department of the Environment for Northern Ireland and provides for certain methods and standards of building which, if followed, will satisfy

More information

Riva Studio Dedicated Sealed External Air Kit

Riva Studio Dedicated Sealed External Air Kit Riva Studio Dedicated Sealed External Air Kit For Studio Duplex Instructions for Use, Installation & Servicing For use in GB & IE (Great Britain & Republic of Ireland). IMPORTANT Please read these instructions

More information

Annex 5a Solid fuel (Domestic) Annex 5a Common Minimum Technical Competency Requirements for Solid fuel burning appliance installation (domestic)

Annex 5a Solid fuel (Domestic) Annex 5a Common Minimum Technical Competency Requirements for Solid fuel burning appliance installation (domestic) Annex 5a Solid fuel (Domestic) Annex 5a Common Minimum Technical Competency Requirements for Solid fuel burning appliance installation (domestic) Routes to demonstrating required competence Inspection

More information

Esse B MODEL Roomheater with boiler WOOD BURNING ONLY MODEL

Esse B MODEL Roomheater with boiler WOOD BURNING ONLY MODEL Esse 700 27B MODEL Roomheater with boiler WOOD BURNING ONLY MODEL Esse Stoves & Cookers Long Ing. Barnoldswick, Lancashire BB18 6BN. United Kingdom. Tel: + 44 (0) 1282 813235 F: + 44 (0) 1282 816876 enquiries@esse.com

More information

Code of Practice - Ventilation- Mechanical Extract Ventilation (MEV) + Mechanical Ventilation with Heat Recovery (MHVR)

Code of Practice - Ventilation- Mechanical Extract Ventilation (MEV) + Mechanical Ventilation with Heat Recovery (MHVR) Code of Practice - Ventilation- Mechanical Extract Ventilation (MEV) + Mechanical Ventilation with Heat Recovery (MHVR) Contractors Requirements & Competency This section outlines the general Standards

More information

Technical Bulletin 005(B) Developed with Building Standards Scotland

Technical Bulletin 005(B) Developed with Building Standards Scotland Technical Bulletin 005(B) Developed with Building Standards Scotland Title: Gas cookers in internal kitchens - Ventilation requirements as applied to Scotland Date issued: 1 July 2015 Note: This version

More information

Prefabricated Insulated Fireplace Recess Liners

Prefabricated Insulated Fireplace Recess Liners 4 Installation, Safety & Maintenance Part 4 - Installation, Safety & Maintenance Other Installation Equipment Prefabricated Insulated Fireplace Recess Liners BASIS OF HETAS LISTING Prefabricated Insulated

More information

ARCHIVED. Compliance Document for New Zealand Building Code Clause G4 Ventilation Second Edition. Prepared by the Department of Building and Housing

ARCHIVED. Compliance Document for New Zealand Building Code Clause G4 Ventilation Second Edition. Prepared by the Department of Building and Housing Compliance Document for New Zealand Building Code Clause G4 Ventilation Second Edition Prepared by the Department of Building and Housing This Compliance Document is prepared by the Department of Building

More information

FMH Range Hoods. Installation, Operation & Maintenance Instructions

FMH Range Hoods. Installation, Operation & Maintenance Instructions Installation, Operation & Maintenance Instructions Fourneaux de France Ltd Unit 3 Albion Close, Newtown Business Park, Poole Dorset, BH12 3LL Tel 01202-733011 Email info@fdef.co.uk www.fdef.co.uk W1103

More information

Part J of the Building Regulations: Changes for 2010 Tuesday 28 th September 2010 Presenter: David Bleicher

Part J of the Building Regulations: Changes for 2010 Tuesday 28 th September 2010 Presenter: David Bleicher Part J of the Building Regulations: Changes for 2010 Tuesday 28 th September 2010 Presenter: David Bleicher 1 The Building Regulations The England & Wales Building Regulations are legal requirements that

More information

CI/SfB (57.7) 1st Edition. Lo-Carbon Response/SELV dmev Unit. A new generation of Lo-Carbon continuous running fans

CI/SfB (57.7) 1st Edition. Lo-Carbon Response/SELV dmev Unit. A new generation of Lo-Carbon continuous running fans CI/SfB (57.7) 1st Edition A new generation of Lo-Carbon continuous running fans Lo-Carbon Response/SELV dmev Unit A new generation of Lo-Carbon continuous running fans Looking towards the future Vent-Axia

More information

Flueless Gas Fires HIGH EFFICIENCY

Flueless Gas Fires HIGH EFFICIENCY Flueless Gas Fires HIGH EFFICIENCY BRITISH DESIGN: CVO Fire has been at the forefront of gas fire design since 1999 using cutting edge technology to create unique desirable gas fires. We are a UK gas fire

More information

PRODUCT GUIDE VENTILATION FLEXI TUBS & BUCKETS GARDENING HARDWARE PLUMBING & DRAINAGE PLASTERING & DECORATION

PRODUCT GUIDE VENTILATION FLEXI TUBS & BUCKETS GARDENING HARDWARE PLUMBING & DRAINAGE PLASTERING & DECORATION PRODUCT GUIDE VENTILATION FLEXI TUBS & BUCKETS GARDENING HARDWARE PLUMBING & DRAINAGE PLASTERING & DECORATION STADIUM BUILDING PRODUCTS ABOUT US Stadium Building Products are regarded as a market leading

More information

SUNWARM AIR SOLAR PRE-HEAT VENTILATION SYSTEM

SUNWARM AIR SOLAR PRE-HEAT VENTILATION SYSTEM SOLAR PRE-HEAT VENTILATION SYSTEM SUNWARM USES SOLAR ENERGY TO REDUCE THE HEATING DEMAND OF THE HOME AS WELL AS PROVIDING A COMPLETE VENTILATION SOLUTION. 76 BENEFITS Sunwarm Air provides both a ventilation

More information

Commissioning of Heat Producing Appliances Burning Solid Fuel

Commissioning of Heat Producing Appliances Burning Solid Fuel Building Control Technical Guidance Leaflet No. 15 This leaflet is one of a series produced by the Hertfordshire Building Control Technical Forum Commissioning of Heat Producing Appliances Burning Solid

More information

PLEASE READ ALL SECTIONS OF THIS GUIDE BEFORE COMMENCING YOUR INSTALLATION AND IN CONJUNCTION WITH YOUR DRAWINGS.

PLEASE READ ALL SECTIONS OF THIS GUIDE BEFORE COMMENCING YOUR INSTALLATION AND IN CONJUNCTION WITH YOUR DRAWINGS. Installation Guide This information is provided as a guide and may differ from project to project. It is assumed that the property is a two storey dwelling. Obviously a bungalow represents a simpler task,

More information

FM900. Installation, Operation and Maintenance Instructions. Built-In Extractor

FM900. Installation, Operation and Maintenance Instructions. Built-In Extractor FM900 Installation, Operation and Maintenance Instructions Built-In Extractor Contents: 1 Introduction 2 Important Information 3 Extraction Performance 4 Installation 5 Operating Instructions 6 Maintenance

More information

Unity CV2GIP Decentralised Mechanical Extract Ventilation (dmev) Installation Instructions

Unity CV2GIP Decentralised Mechanical Extract Ventilation (dmev) Installation Instructions Unity CV2GIP Decentralised Mechanical Extract Ventilation (dmev) Installation Instructions Commissioning Data: To be completed by the Commissioning Engineer. Refer to User / Homeowner Guide also supplied.

More information

Blancoair Extractor Hoods

Blancoair Extractor Hoods Blancoair Extractor Hoods As individual as you are! www.blanco.co.uk Blancoair Creative cooking is an activity that many of us enjoy. There is little doubt that part of the enjoyment of food is the evocative

More information

Airflex Radial & ISO Thermal pipe

Airflex Radial & ISO Thermal pipe Airflex Radial & ISO Thermal pipe Semi rigid ducting Key Features Zero leakage ensures highest performance 70% time saving on installation Interchangeable ducting system (75mm round / 51mm x 114mm oval)

More information

Technician s guide to best practice FINAL Draft v October Flues, chimneys and combustion air ventilators.

Technician s guide to best practice FINAL Draft v October Flues, chimneys and combustion air ventilators. Technician s guide to best practice FINAL Draft v October 2016 Flues, chimneys and combustion air ventilators. Flues chimneys & combustion air ventilators is published by the Cavity Insulation Guarantee

More information

5.5.1 General CD/30 (Oil Condensing Boiler Installation Assessment Form) General Technician Stationary...

5.5.1 General CD/30 (Oil Condensing Boiler Installation Assessment Form) General Technician Stationary... 5.5.1 General... 13 5.6 CD/30 (Oil Condensing Boiler Installation Assessment Form)... 15 5.6.1 General... 15 5.7 Technician Stationary... 18 5.7.1 CD/40 Energy Efficiency Checklist... 18 5.8 Work Notification

More information

Product Data Sheet. Astro Strip

Product Data Sheet. Astro Strip Product Data Sheet Astro Strip Revision 4 - September 2018 Astroflame (Fireseals) LTD : Unit 8, I.O Centre : Stephenson Road : Segensworth : Fareham : PO15 5RU T - 01329 844500 : F - 01329 844600 : : Astro

More information

flueless gas fires & stoves

flueless gas fires & stoves flueless gas fires & stoves The Lynwood Suite Limestone surround which includes the Astute fire Astute Burley s range of Flueless gas fires give levels of convenience, efficiency and safety to which flued

More information

Accessories Flue Systems

Accessories Flue Systems Accessories Flue Systems Installation Accessories Trade Catalogue iso 9001 FS 576960 1Introduction About Us Flue Supplies is a family-run company with over 20 years direct experience of selling chimney

More information

BACKGROUND VENTILATION SOLUTIONS FOR DOMESTIC BUILDINGS

BACKGROUND VENTILATION SOLUTIONS FOR DOMESTIC BUILDINGS ...................................... CI/SfB (57) Uniclass L753 July 2015 BACKGROUND VENTILATION SOLUTIONS FOR DOMESTIC BUILDINGS................................................................... ...................................................................................

More information

60cm Chimney Extractor

60cm Chimney Extractor 60cm Chimney Extractor LAM2401 HJA2480 User & Installation Guide Contents Page Environmental note 3 IMPORTANT SAFETY INFORMATION 4 6 Specifications of your extractor 7 8 Dimensions 7 Specifications 7-8

More information

VPC Gas Cabinet Heater Range

VPC Gas Cabinet Heater Range VPC Gas Cabinet Heater Range Industrial & Commercial Heating Systems. www.powrmatic.co.uk HEATING // VENTIATION // AIR CONDITIONING // OEM PRODUCTS VPC Overview Models Available VPC UF - Upright Freeblowing

More information

Instruction Manual JLHDA cm Cooker hood

Instruction Manual JLHDA cm Cooker hood Contents 3 Introduction 3 Safety is important 3 In the box 4 Safety information 4 Important safety information 4 Warnings 5 Cautions 5 Electrical information 6 Remote control 6 Programming the remote control

More information

IS-ORANGE Envirograf. Orange Book. Ventilation. T +44 (0) F +44 (0)

IS-ORANGE Envirograf. Orange Book. Ventilation. T +44 (0) F +44 (0) IS-ORANGE-01-15 Orange Book Ventilation Envirograf Innovators - Developers - Manufacturers Passive Fire Prevention Products T +44 (0) 1304 842 555 F +44 (0) 1304 842 666 sales@envirograf.com www.envirograf.com

More information

TECHNICAL BOOK 4: OIL FIRED APPLIANCE & SYSTEM INSTALLATION REQUIREMENTS

TECHNICAL BOOK 4: OIL FIRED APPLIANCE & SYSTEM INSTALLATION REQUIREMENTS 3.18.6 Independent Control of Two Space and One Water Heating Circulation Zones in a Fully Pumped System with Three Motorised Valves... 64 3.19 Non Domestic Systems and Processes... 64 SECTION 4 FUEL CONSERVATION

More information

Installation Guide Atmospherix and Atmospherix A20

Installation Guide Atmospherix and Atmospherix A20 Installation Guide Atmospherix and Atmospherix A20 Congratulations on choosing Krix Your Krix speakers are designed to reproduce the highest quality sound. To get the best performance from your speakers

More information

Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System Installation Instructions

Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System Installation Instructions Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System Installation Instructions Commissioning Data: To be completed by the Commissioning Engineer. Refer to User/Homeowner Guide

More information

S T O R E R A N G E C Y L I N D E R & G R A N T FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS

S T O R E R A N G E C Y L I N D E R & G R A N T FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS G R A N T C Y L I N D E R & S T O R E R A N G E High Efficiency Direct and Indirect Hot Water Storage Solutions FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS GRANT DUOWAVE

More information

CP+ Gas & Oil Cabinet Heater Range

CP+ Gas & Oil Cabinet Heater Range CP+ Gas & Oil Cabinet Heater Range Industrial & Commercial Heating Systems. www.powrmatic.co.uk CP+ CP+EA External Heater HEATING // VENTILATION // AIR CONDITIONING // OEM PRODUCTS CP+ Overview Designed

More information

Ventilation & Heat Recovery. The whole house system from OMNIE

Ventilation & Heat Recovery. The whole house system from OMNIE Ventilation & Heat Recovery The whole house system from OMNIE 2 Contents ABOUT OMNIE 4 The Whole house system 6 Why OMNIE Ventilation & Heat Recovery? 7 How does it work? PRODUCT 9 Comfo Air Q MVHR Unit

More information

Leading lighter lifestyles. Aspect bi-folding doors

Leading lighter lifestyles. Aspect bi-folding doors Leading lighter lifestyles Aspect bi-folding doors Get the WOW factor The Aspect bi-fold door collection The superb collection of Aspect bi-fold doors offers market-leading aesthetics, engineering and

More information

EXTRACTOR HOOD. Please read all the instructions carefully before starting the installation. 230 / 240V 50Hz

EXTRACTOR HOOD. Please read all the instructions carefully before starting the installation. 230 / 240V 50Hz abc EXTRACTOR HOOD Please read all the instructions carefully before starting the installation Model Stock Ref Napoli 120812 Napoli Plus (white) 436083 Napoli Plus (Silver) 436084 230 / 240V 50Hz PLEASE

More information

Vision Air Conditioning Range Condenser-less Air Conditioner

Vision Air Conditioning Range Condenser-less Air Conditioner Powrmatic Vision 2.3 Condenser-less Air Conditioner Includes DC Inverter & Low Temperature Hot Water Models Vision Air Conditioning Range Condenser-less Air Conditioner S T Y L I S H & C O S T E F F E

More information

Stockton 7 & 8 Inset Convector Stove

Stockton 7 & 8 Inset Convector Stove Stockton 7 & 8 Inset Convector Stove Installation Instructions MODELS: 7125/7126 For Use in Great Britain and Eire This product is suitable for use in the stated countries. To install the product in other

More information

Belling Classic 900mm range cookers. The Range Cooker Collection 2010

Belling Classic 900mm range cookers. The Range Cooker Collection 2010 Belling Classic 900mm range cookers 1 The Range Cooker Collection 2010 2 Belling Range Cooker Collection Belling Range Cooker Collection Contents 900mm ranintroduction 3 Contents Glossary 4-5 Belling Classic

More information

Fire and smoke protection for ventilation

Fire and smoke protection for ventilation IS-ORANGE-01-15 Ventilation Innovators - Developers - Manufacturers Passive Fire Prevention Products Fire and smoke protection for ventilation Products 14 Intumescent Fan Covers (FOR WINDOWS AND WALLS)

More information

Twin Wall Installation Instructions And Maintenance Guide

Twin Wall Installation Instructions And Maintenance Guide Twin Wall Installation Instructions And Maintenance Guide Please read all instructions before beginning your installation. Failure to install this system in accordance with these instructions will invalidate

More information

IF IN DOUBT, INSTALLATION SHOULD BE MADE BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH CURRENT WIRING REGULATIONS.

IF IN DOUBT, INSTALLATION SHOULD BE MADE BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH CURRENT WIRING REGULATIONS. INSTALLATION/OPERATING INSTRUCTIONS FOR C100 & C100T Thank you for purchasing a quality Extractor fan from Greenbrook. Please read these instructions fully prior to initial use. Every effort has been made

More information

The Glidevale range of Fresh wall

The Glidevale range of Fresh wall CI/SfB (57) Uniclass Pr_30_59_96 December 2017 The Glidevale range of Fresh wall ventilators has been specially designed to introduce fresh air into our homes in order to control condensation, and being

More information

Ventilation and Hand Dryers

Ventilation and Hand Dryers Ventilation Product Catalogue 2018 Ventilation and Hand Dryers Ventilation Fans are attractively styled to blend with modern environments whatever the application, from kitchens and bathrooms to utility

More information

CANOPY RANGEHOOD ONBOARD INSTALLATION INSTRUCTIONS

CANOPY RANGEHOOD ONBOARD INSTALLATION INSTRUCTIONS Congratulations on your purchase! Thank you for choosing a Sirius product. CANOPY RANGEHOOD ONBOARD INSTALLATION INSTRUCTIONS SLTC 97 900 EAN# 9351116001612 SL22 900 EAN# 9351116000660 SL7 1200 EAN# 9351116000813

More information

VPC Gas Cabinet Heater Range Architects of your environment. heating ventilation air conditioning

VPC Gas Cabinet Heater Range Architects of your environment. heating ventilation air conditioning VPC Gas Cabinet Heater Range Architects of your environment heating ventilation air conditioning 1 Product Overview Benefits Installer Friendly ow evel Flue Discharge Option (No Roof Work) Room Sealed

More information

i PSV WHOLE-HOUSE VENTILATION SYSTEM

i PSV WHOLE-HOUSE VENTILATION SYSTEM CI/SfB (57) Uniclass Ss_65_40_33_56 November 2017 i PSV WHOLE-HOUSE VENTILATION SYSTEM Humidity-sensitive wall ventilator Energy saver vent................................ HOW TRADITIONAL PASSIVE STACK

More information

enviroblinds external blinds & shutters the secret to low carbon comfort

enviroblinds external blinds & shutters the secret to low carbon comfort ROLLER SHUTTERS technical brochure enviroblinds external blinds & shutters the secret to low carbon comfort CONTENTS BENEFITS Page 3 The secret to low carbon comfort; Enviroblinds stylish external blinds

More information

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP RV Products A Division of Airxcel, Inc. P.O. Box 4020 Wichita, KS 67204 1976-360 (1-02) PP TABLE OF CONTENTS 1. Warnings......................................................

More information

INSTALLATION & COMMISSIONING INSTRUCTIONS Model: 990 CH

INSTALLATION & COMMISSIONING INSTRUCTIONS Model: 990 CH INSTALLATION & COMMISSIONING INSTRUCTIONS Model: 990 CH TABLE OF CONTENTS General Safety Information Page 2 Chimney and Flue Information Page 3 Installing the Appliance Page 4 Flue Draught Page 5 Chimney

More information

LANDLORDS & LETTINGS VENTILATION SOLUTIONS

LANDLORDS & LETTINGS VENTILATION SOLUTIONS LANDLORDS & LETTINGS VENTILATION SOLUTIONS CREATING A HEALTHY INDOOR ENVIRONMENT CONTENTS INTRODUCTION... 3 WHY IS VENTILATION IMPORTANT?...4 CURE CONDENSATION FOR GOOD... 5 THE DRIMASTER RANGE... 6 SINGLE

More information

Loss Prevention Standards

Loss Prevention Standards Introduction Fire compartmentation is an essential part of an effective fire safety design of a building. The primary objective of fire compartmentation or passive fire protection is to prevent a building

More information

vent With family and friends to take care of, it goes without saying you need the help of reliable kitchen appliances.

vent With family and friends to take care of, it goes without saying you need the help of reliable kitchen appliances. vent With family and friends to take care of, it goes without saying you need the help of reliable kitchen appliances. 55 Specs Downdraft Surrounds Downdraft Small Surround Surrounds and grills are available

More information

I n s t r u c t i o n m a n u a l f o r b u i l t - i n h o o d. Model code: BORA600

I n s t r u c t i o n m a n u a l f o r b u i l t - i n h o o d. Model code: BORA600 I n s t r u c t i o n m a n u a l f o r b u i l t - i n h o o d Model code: BORA600 Contact Caple on 0844 8003830 or for spare parts www.4caple.co.uk 1 Y O U R A P P L I A N C E Thank you for buying your

More information

Chrome. Approximately 26 seconds drying time. 1.0kW Automatic Eco Fast Dryer Epoxy Coated. 1.2mm thick steel cover

Chrome. Approximately 26 seconds drying time. 1.0kW Automatic Eco Fast Dryer Epoxy Coated. 1.2mm thick steel cover Automatic & Manual Hand dryers for Commercial Applications 1.1kW Compact Eco Swift 409733 409734 Satin Stainless Steel 409735 Polished Stainless Steel Intelligent sensing, element auto switch off when

More information

Baxi Brazilia F 5, F 5S, F 8S & Comfort Stat F 8ST Oak

Baxi Brazilia F 5, F 5S, F 8S & Comfort Stat F 8ST Oak Baxi Brazilia F 5, F 5S, F 8S & Comfort Stat F 8ST Oak Balanced Flue Gas Wall Heaters Please leave these instructions with the user User s Operating Instructions Baxi Brazilia F 5 Baxi Brazilia F 5S Baxi

More information

WASHROOM DESIGN SOLUTIONS THIRD EDITION

WASHROOM DESIGN SOLUTIONS THIRD EDITION CI/SfB (74) X WASHROOM DESIGN SOLUTIONS THIRD EDITION It s a Dolphin Thing Dolphin Solutions Ltd is a reliable and resourceful company built upon a foundation of integrity, honesty, enthusiasm and a caring

More information

VASKA C11. gas -fireplace installation guide

VASKA C11. gas -fireplace installation guide VASKA C11 gas -fireplace installation guide Saturnus 8 NL-8448 CC Heerenveen Postbus 219 NL-8440 AE Heerenveen T. +31(0)513 656500 F. +31(0)513 656501 40 010 459 01 51 DESCRIPTION OF THE FIREPLACE CONTENTS

More information

gas log fires freestanding & inbuilts

gas log fires freestanding & inbuilts gas log fires freestanding & inbuilts why choose Regency? An exceptional fire, custom elegance and controllable heat are just a few reasons to make a Regency fire part of your family. In 1979, I founded

More information

JLBIHD624 60cm Cooker Hood

JLBIHD624 60cm Cooker Hood JLBIHD624 60cm Cooker Hood User guide 2 Cooker hood user guide Contents Contents 3 Introduction 4 Safety is important 4 In the box 4 Safety information 5 Important safety information 5 Warnings 5 Cautions

More information

Cooker Hood CHIM60 CHIM70 CHIM90 CHIM101 CHIM110. Installation & User s instructions

Cooker Hood CHIM60 CHIM70 CHIM90 CHIM101 CHIM110. Installation & User s instructions Cooker Hood CHIM60 CHIM70 CHIM90 CHIM101 CHIM110 Installation & User s instructions 2 250 20.5 167.5 A 590 : 960 260 330 Max 370 E F 304 278 42 206 167 Z B C D 230 230 Fig.1 Fig.3 G E A Z Z F B Y C D 490

More information

"Let's provide you with a superior User Experience delivering Ease-of-Mind."

Let's provide you with a superior User Experience delivering Ease-of-Mind. "Let's provide you with a superior User Experience delivering Ease-of-Mind." contents 2 Safety warnings...3 For the installer...3 For the user...3 Installation...4 Unpacking...4 Location...4 Electrical

More information

THE CAPITAL COLLECTION CONTEMPORARY FIREPLACES

THE CAPITAL COLLECTION CONTEMPORARY FIREPLACES 3967_CAPITAL_CONTEMPORARY 13/9/06 2:23 pm Page 1 THE CAPITAL COLLECTION CONTEMPORARY FIREPLACES 2006-2007 3967_CAPITAL_CONTEMPORARY 13/9/06 2:23 pm Page 2 1 LB-30 FRAME 30 (762mm) brushed stainless steel

More information

Graphite. Everything you want from a wood burning stove. and then some...

Graphite. Everything you want from a wood burning stove. and then some... Everything you want from a wood burning stove and then some... Energy independence and energy efficiency... as well as kinder to planet Earth. Forget about whether or not wood burning stoves are the latest

More information

Installation and Maintenance

Installation and Maintenance 1.0 Introduction MRXBOX-ECO2 (Standard Unit) MRXBOX-ECO2-OH (Opposite hand Unit) MRXBOXAB-ECO2 (Standard Unit) MRXBOXAB-ECO2-OH (Opposite hand Unit) Mechanical Ventilation Units with Heat Recovery for

More information

Heat your whole home in just 10 minutes!

Heat your whole home in just 10 minutes! Heat your whole home in just 10 minutes! www.bonaire.co.nz Whole home heating Heats up Fast Ducted gas heating is the fastest way to heat up your whole home State of the art controls Bonaire uses advanced

More information

COOKER HOOD USER HANDBOOK FOR INSTALLATION AND OPERATION MODELS CRC95

COOKER HOOD USER HANDBOOK FOR INSTALLATION AND OPERATION MODELS CRC95 COOKER HOOD USER HANDBOOK FOR INSTALLATION AND OPERATION MODELS CRC95 Your new Cooker Hood Using your new Cooker Hood is very simple. Nevertheless, to get the best results it is important that you read

More information

SFA Guide to Building Regulations and Solid Fuel Heating

SFA Guide to Building Regulations and Solid Fuel Heating SFA Guide to Building Regulations and Solid Fuel Heating Solid Fuel Association 95 High Street Clay Cross Chesterfield Derbyshire S45 9DZ 01773 835400 www.solidfuel.co.uk Building Regulations and Solid

More information

Intumescent Fire Seals

Intumescent Fire Seals Trade Name: ASTRO STRIP Intumescent Fire Seals Certifire Approved Fire Seals & Smoke Seals Intumescent Fire Seals Astrostrip FO - fire only seals. Intumescent seals for use where no smoke sealing is required.

More information

Automatic Smoke & Fire Curtain Surveying Manual. Table of Contents. Before the Survey 2. Carrying out the Survey 2-3

Automatic Smoke & Fire Curtain Surveying Manual. Table of Contents. Before the Survey 2. Carrying out the Survey 2-3 Automatic Smoke & Fire Curtain Surveying Manual Table of Contents Before the Survey 2 Carrying out the Survey 2-3 Site Survey Further Information 3-6 Site Survey Report Sheet 7-8 Smoke & Fire Curtains

More information

RANGE COOKERS ELECTRIC WOOD GAS OIL EVEN BETTER COOKING SINCE 1854

RANGE COOKERS ELECTRIC WOOD GAS OIL EVEN BETTER COOKING SINCE 1854 RANGE COOKERS ELECTRIC WOOD GAS OIL EVEN BETTER COOKING SINCE 1854 Whatever the recipe, however many you ve invited the 990 EL will never cramp your cooking style. THE ELECTRIC RANGE COOKER The 990 EL

More information

SAC 100 Automatic Smoke Curtain System. - Specifier Information -

SAC 100 Automatic Smoke Curtain System. - Specifier Information - SAC 100 Automatic Smoke Curtain System - Specifier Information - CONTENTS 1. Introduction Page 3 2. Construction and Method of Operation Page 5 3. Performance 3.1. Resistance to Fire/Heat Page 6 3.2. Deflection

More information

User Guide. Promax SL Condensing Central Heating Boiler

User Guide. Promax SL Condensing Central Heating Boiler United Kingdom en User Guide Condensing Central Heating Boiler Promax SL 12-15 - 18-24 Please keep these instructions in a safe place. If you move house, please hand them over to the next occupier. Contents

More information

BT16.4SS-HK BT19.4SS-HK Cooker Hood

BT16.4SS-HK BT19.4SS-HK Cooker Hood BT16.4SS-HK BT19.4SS-HK Cooker Hood User Manual for your Baumatic User Manual for your Baumatic BT16.4SS-HK 60 cm Chimney Hood BT19.4SS-HK 90 cm Chimney Hood NOTE: This User Instruction Manual contains

More information

Please note: Not all frames, finishes, linings or fuel effects illustrated throughout this brochure may be available as a stock item.

Please note: Not all frames, finishes, linings or fuel effects illustrated throughout this brochure may be available as a stock item. Please note: Not all frames, finishes, linings or fuel effects illustrated throughout this brochure may be available as a stock item. Please discuss your requirements with your retailer to confirm availability

More information

INSTALLATION AND USER S MANUAL COOKER HOOD RS-600/A-S

INSTALLATION AND USER S MANUAL COOKER HOOD RS-600/A-S INSTALLATION AND USER S MANUAL COOKER HOOD RS-600/A-S RS-600 (CHS60SS)-GB-05.indd 1 6/8/2010 9:30:59 AM TABLE OF CONTENTS 1. Introduction 2 2. Safety precaution 2 3. Intended use 3 4. Parts supplied 3

More information

Gas Safety Devices & Accessories

Gas Safety Devices & Accessories Gas Safety Devices & Accessories Gas Interlocks (GIS units) are required in most commercial kitchens, these systems require a number of components to comply with UK legislation. GIS UNITS WITH INTEGRAL

More information

CANOPY RANGEHOOD OFFBOARD INSTALLATION INSTRUCTIONS

CANOPY RANGEHOOD OFFBOARD INSTALLATION INSTRUCTIONS Congratulations on your purchase! Thank you for choosing a Sirius product. CANOPY RANGEHOOD OFFBOARD INSTALLATION INSTRUCTIONS SLTC EM 107 G900 EAN# 9351116001766 SLEM 107 S900 EAN# 9351116001759 SLEM

More information

User Guide and Important Warranty Information. Suprima HE. Condensing Central Heating Boiler. Please read this document and keep it safe.

User Guide and Important Warranty Information. Suprima HE. Condensing Central Heating Boiler. Please read this document and keep it safe. User Guide and Important Warranty Information Suprima 30-80 HE Condensing Central Heating Boiler Please read this document and keep it safe. It will help you out should your boiler need attention. Introduction

More information

Biomass. Biomass solid fuel boiler range

Biomass. Biomass solid fuel boiler range Biomass Biomass solid fuel boiler range Biomass Fuelling positive change For more than150 years, Baxi has been at the forefront of heating technology Baxi leads the way with new and pioneering heating

More information

DUCTING FOR HRV SYSTEMS The distribution of airflows

DUCTING FOR HRV SYSTEMS The distribution of airflows DUCTING FOR HRV SYSTEMS The distribution of airflows As we saw in my two previous articles, Heat Recovery Ventilation (HRV) gives healthy and comfortable ventilation whatever the weather. And in wintertime,

More information

Domestic Heating Compliance Guide

Domestic Heating Compliance Guide Domestic Heating Compliance Guide May 2006 1st Edition The Building Regulations 2000 As amended 2006 DOMESTIC HEATING COMPLIANCE GUIDE COMPLIANCE WITH APPROVED DOCUMENTS L1A: NEW DWELLINGS L1B: EXISTING

More information

FIRE INSPECTION GUIDELINES FOR FOSTER GROUP HOME PARENTS Effective June 1, 2002, Update September 2011

FIRE INSPECTION GUIDELINES FOR FOSTER GROUP HOME PARENTS Effective June 1, 2002, Update September 2011 HCFMO Harris County Fire Marshal M.S. Montgomery Fire Marshal FIRE INSPECTION GUIDELINES FOR FOSTER GROUP HOME PARENTS Effective June 1, 2002, Update September 2011 EFFECTIVE JANUARY 1, 2007 These guidelines

More information

Domestic Gas Safety Assessments (DGA) Competency Assessment Certification Scheme for Registered Gas Installers

Domestic Gas Safety Assessments (DGA) Competency Assessment Certification Scheme for Registered Gas Installers Domestic Gas Safety Assessments (DGA) Competency Assessment Certification Scheme for Registered Gas Installers Knowledge and Understanding Assessment Performance Criteria Issue 1 (September 2013) Public

More information

Troubleshooting Guide

Troubleshooting Guide Troubleshooting Guide CONTENTS 1: Door Glass Blackening...Troubleshooting 1, page 3 This Troubleshooting guide is supplementary to, and must be used in conjunction with, the Instructions for Use, Installation

More information

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS UNDER CABINET HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside MRXBOX95-WM1 (Standard Unit) MRXBOX95-WM1-OH (Opposite hand Unit) MRXBOX95AB-WM1 (Standard Unit) MRXBOX95AB-WM1-OH (Opposite hand Unit) Mechanical Ventilation Units with Heat Recovery for Wall Mounting

More information

Serenity Range. Inset and freestanding Stoves. Warming your world. Multifuel Stoves for the home DESIGNED & MANUFACTERED IN THE UK

Serenity Range. Inset and freestanding Stoves. Warming your world. Multifuel Stoves for the home DESIGNED & MANUFACTERED IN THE UK Serenity Range Multifuel Stoves for the home Inset and freestanding Stoves DESIGNED & MANUFACTERED IN THE UK Warming your world Serenity Range Clean burning performance for today s homes Every model in

More information

Model: Kair Whole House Ventilator Model Number: KHRVWH2000

Model: Kair Whole House Ventilator Model Number: KHRVWH2000 Model: Kair Whole House Ventilator Model Number: KHRVWH2000 Installation, Maintenance Instructions and User Guide Unit 6 Chiltonian Industrial Estate 203 Manor Lane, Lee, London. SE12 0TX Tel: 08451 60

More information