THE WALL-MOUNT TM QUIET CLIMATE HEAT PUMPS

Size: px
Start display at page:

Download "THE WALL-MOUNT TM QUIET CLIMATE HEAT PUMPS"

Transcription

1 THE WLL-MOUNT TM QUIET LIMTE HET PUMPS Models: S26H to S6H EER Heating apacities: 2, to, TUH ooling apacities: 2, to, TUH GREEN REFRIGERNT R-4 The ard Wall-Mount Heat Pump is a self-contained energy efficient heating and cooling system, which is designed to offer maximum indoor comfort at a minimal cost without using valuable indoor floor space or outside ground space. This unit is the ideal product for versatile applications such as: new construction, modular offices, school modernization, telecommunication structures, portable structures or correctional facilities. Factory or field installed accessories are available to meet specific job requirements. Engineered Features luminum Finned opper oils: Grooved tubing and enhanced louvered fin for maximum heat transfer and energy efficiency. Twin lowers: Move air quietly. Most models feature multispeed blower motors providing airflow adjustment for high and low static operation. Motor overload protection is standard on all models. EM Indoor lower Motor: Features a variable speed motor providing super-high efficiency, low sound levels and softstart capabilities. The motor is self-adjusting to provide the proper airflow rate for the staged capacity, and for higher static pressure in ducted installations without user adjustment or wiring changes. Standard 2-speed PS motor is used on Models S26H & S3H. Heat Pump ompressor: ompressors are standard on all ½ to ton models. Eliminates need for crankcase heater. Phase Rotation Monitor: Standard on all 3 phase scroll compressors. Protects against reverse rotation if power supply is not properly connected. R-4 Refrigerant: Designed with R-4 (HF) non-ozone depleting refrigerant in compliance with the Montreal protocol and 2 EP requirements. Liquid Line Filter Drier: Standard on all units. Protects system against moisture. Galvanized 2 Gauge Zinc oated Steel abinet: leaned, rinsed, sealed and dried before the polyurethane primer is applied. The cabinet is handsomely finished with a baked on, beige textured enamel, which allows it to withstand hours of salt spray tests per STM 7-3. Foil Faced Insulation: Standard on all units. Electrical omponents: re easily accessible for routine inspection and maintenance through a right side, service panel opening. Features a lockable, hinged access cover to the circuit breaker or toggle disconnect switch. Electric Heat Strips: Features an automatic limit and thermal cutoff safety control. Heater packages are factory or field installed for all ½ through ton models. Features easy slide-in field assembly with various TUH outputs. ondenser Fan and Motor Shroud ssembly: Slide out for easy access. Filter Service Door: Separate service door provides easy access for filter change. One Inch, Disposable ir Filters: re standard equipment. Optional one inch washable filters available and filter racks permit the addition of 2" pleated filter. Factory or field installed. Solid State Electronic Heat Pump ontrol: Provides efficient 3, or 9 minute defrost cycle. thermistor sensor, speed up terminal for service and minute defrost override are standard on the electronic heat pump control. High & Low Pressure Switches are uto- Reset: Standard on all units. uilt-in lockout circuit resets from the room thermostat. Provides commercial quality protection to the compressor. Five Minute ompressor Time Delay: Short cycle protection is standard. uilt into the heat pump control. Emergency Heat ircuit: Permits continuous operation of the system. arometric Fresh ir Damper: Standard on all units. llows up to 2% outside fresh air. uilt-in ircuit reakers: Standard on all electric heat versions of single and three phase (23/28 volt) equipment. Toggle disconnects are standard on all electric heat versions of three phase (4 volt) equipment. Slope Top: Standard feature for water run-off. Full Length Mounting rackets: uilt into cabinet for improved appearance and easy installation. NOTE: ottom mounting bracket included to assist in installation. Top Rain Flashing: Standard feature on all models. Ventilation System Packages Six ventilation options are available. See Page 3 for details on these options. omplies with efficiency requirements of NSI/SHRE/IESN ertified to NSI/RI Standard for SPVU (Single Package Vertical Units). Intertek ETL Listed to Standard for Safety Heating and ooling Equipment NSI/UL 99/S 22.2 No. 236-, Third Edition. ommercial Product - Not intended for Residential application. Form No. S346- Supersedes S346-9 Page of 6

2 apacity and Efficiency Ratings MODELS S26H S3H S38H S43H S49H S6H ooling TUH 2, 28,4 36, 4, 46,, EER High Temp Heating (47F) TUH 24,4 28, 3, 39, 4,, OP Low Temp Heating (7F) TUH, 7, 2, 23, 26, 3, OP apacity is certified in accordance with NSI/RI Standard EER = Energy Efficiency Ratio, OP = oefficient of Performance and are certified in accordance with NSI/RI Standard ll ratings based on fresh air intake being % closed (no outside air introduction). Specifications 2 through 3 Ton S26H- 3/ S26H- - - S3H- 3/ S3H- 3/ S3H- - - S38H- 3/ S38H- 3/ S38H / /28 23/ /28 23/ /8.../7. 9./.. 2./..4/ / /77 7/7 38 / 2 88/88 44 /-- /-- /-- /-- /-- / / / "-9 2"-9 2"-9 2"-9 2"-9 24"-29 24"-29 24"-29 MODELS S26H- Electrical Rating -- HZ 3/28- Operating Voltage Range ompressor -- ircuit Voltage 3/28 Rated Load mps.8/. 4 ranch ircuit Selection urrent 2. 9 Lock Rotor mps 4/64 ompressor Type Fan Motor & ondenser Fan Motor -- HP - RPM - SPD /-- Fan Motor -- mps. Fan -- DI - FM "-9 Motor & Evaporator lower Motor -- HP - RPM - SPD /-8-2 lower Motor -- mps. 4 FM ooling & E.S.P. w/filter (Rated - Wet oil) -. Filter Sizes (inches) 6 x 3 x Shipping Weight -- LS. /-8-2 /-8-2 /-8-2 /-8-2 /-8-2 /2 Var. /2 Var. /2 Var x 3 x 6 x 3 x 6 x 3 x 6 x 3 x 6 x 3 x 2 x 3 x 2 x 3 x 2 x 3 x Specifications 3-/2 through Ton S43H- 2 23/ S43H- - - S49H- 3/ S49H- 3/ S49H- - - S6H- 3/ S6H- 3/ S6H / /28 23/ /28 23/28 4.8/ /23../ / / /83 4 3/3 98/98 34/34 / MODELS S43H- Electrical Rating -- HZ 3/28- Operating Voltage Range ompressor -- ircuit Voltage 3/28 Rated Load mps 7.2/9. ranch ircuit Selection urrent 9. 9 Lock Rotor mps 9/9 ompressor Type Fan Motor & ondenser Fan Motor -- HP - RPM - SPD / Fan Motor -- mps. Fan -- DI - FM 4"-29 Motor & Evaporator lower Motor -- HP - RPM - SPD /4 Var. lower Motor -- mps. FM ooling & E.S.P. w/filter (Rated - Wet oil) 2 -. Filter Sizes (inches) x 3 x Shipping Weight -- LS. / /3-82- / / /3-82- / / / "-29 24"-29 24"-29 24"-29 24"-29 24"-29 24"-29 24" /4 Var. 3 /4 Var. 3 /4 Var. 3 /4 Var. 3 /4 Var. 3 /4 Var. 3 /4 Var. 3/4 Var x 3 x 2 x 3 x 2 x 3 x 2 x 3 x 2 x 3 x 2 x 3 x 2 x 3 x 2 x 3 x Form No. S346- Supersedes S346-9 Page 2 of 6

3 Ventilation System Packages ard Wall-Mounts are designed to provide optional ventilation packages to meet all of your ventilation and indoor air quality requirements. ll units are equipped with a barometric fresh air damper as the standard ventilation package. ll ventilation packages can be built-in at the factory, or field-installed at a later date. ROMETRI FRESH IR DMPER - FD STNDRD The barometric fresh air damper is a standard feature on all models. It is installed on the inside of the service door and allows outside ventilation air, up to 2% of the total airflow rating of the unit, to be introduced through the air inlet openings and to be mixed with the conditioned air. The damper opens during blower operation and closes when the blower is off. djustable blade stops allow different amounts of outside air to be introduced into the building and can be easily locked closed if required. arometric Fresh ir Damper LNK OFF PLTE - OP OPTIONL blank off plate is installed on the inside of the service door. It covers the air inlet openings which restricts any outside air from entering into the unit. The blank off plate should be utilized in applications where outside air is not required to be mixed with the conditioned air. MOTORIZED FRESH IR DMPER - MFD OPTIONL The motorized fresh air damper is internally mounted behind the service door and allows outside ventilation air, up to 2% of the total airflow rating of the unit, to be introduced through the air inlet openings and to be mixed with the conditioned air. The two position damper can be fully open or closed. The damper blade is powered open by a 24V motor with spring return on power loss. The damper can be controlled by indoor blower operation or can be field connected to be managed based on building occupancy. Motorized Fresh ir Damper NOTE: The above vent systems are intake only without built-in exhaust capability. uilding will likely require separate field installed barometric relief or mechanical exhaust elsewhere within the conditioned space. alancing dampers in the return air grille may be required to achieve specified amount of outdoor air intake. OMMERIL ROOM VENTILTOR - RV OPTIONL The built-in commercial room ventilator is internally mounted behind the service door and allows outside ventilation air, up to % of the total airflow rating of the unit, to be introduced through the air inlet openings. It includes a built-in exhaust air damper. ommercial Room Ventilator The commercial room ventilator (RV) is a simple and innovative approach to improving the indoor air quality by providing fresh air intake and exhaust capability through the RV. The damper can be easily adjusted to control the amount of fresh air supplied into the building. The RV can be controlled by indoor blower operation or field controlled based on room occupancy. The RV is power open - spring return on power loss. omplies with NSI/ SHRE Standard 62. Ventilation for cceptable Indoor ir Quality. Two Models vailable: RVS - spring return on power loss or deactivation RVP - power return (will not close on power loss) EONOMIZER - EIFM OPTIONL The built-in economizer system is internally mounted behind the service door and allows outdoor air to be introduced through the air inlet openings. The amount of outdoor air varies in response to the system controls and settings defined by the end user. It includes a built-in exhaust air damper. The economizer is designed to provide free cooling when outside air conditions are cool and dry enough to satisfy cooling requirements without running the compressor. This in turn provides lower operating costs, while extending the life of the compressor. Economizer Energy Recovery Ventilator Standard Features: One Piece onstruction - Easy to install with no mechanical linkage adjustment required. Exhaust ir Damper - uilt in with positive closed position. Provides exhaust air capability to prevent pressurization of tight buildings. ctuator Motor - 24 volt, power open, spring return with built in torque limiting switch. Proportioning Type ontrol - for maximum free cooling economy and comfort. Moisture Eliminator & Prefilter - permanent, washable aluminum construction. Enthalpy ontrol - adjustable to monitor outdoor temperature and humidity. Minimum Position Potentiometer - adjustable to control minimum damper blade position for ventilation purposes. Mixed ir Sensor - to monitor outside and return air to automatically modulate damper position. WLL-MOUNT ENERGY REOVERY VENTILTOR - WERV OPTIONL The wall-mount energy recovery ventilator (WERV) is a highly innovative approach to meeting indoor air quality ventilation requirements as established by NSI/SHRE Standard 62.. The WERV allows from 2 to 4 FM (depending upon model) of fresh air and exhaust through the unit while maintaining superior indoor comfort and humidity levels. In most cases this can be accomplished without increasing equipment sizing or operating costs. Heat transfer efficiency is up to 67% during summer and 7% during winter conditions. The WERV consists of a unique rotary energy recovery cassette that provides effective sensible and latent heat transfer capabilities during summer and winter conditions. Various control schemes are addressed including limiting ventilation during building occupancy only. The WERV is designed to be internally mounted behind the service door in the W, WH or WL model wall-mount units. It can be built-in at the factory or field installed as an option. WERV-*3 and WERV-* can be independently adjusted for intake and exhaust rates. Manufactured under U.S. Patent Nos.,48,878;,3,744;,2,6. Form No. S346- Supersedes S346-9 Page 3 of 6

4 ommercial Room Ventilator Performance Data : RVS-3 and RVP-3 S26H & S3H High Speed Total and Ventilation irflow IRFLOW (FM) 4 3 Total ir ESP Total ir. ESP Vent ir ESP Vent ir. ESP 2 D E F Vent Position S26H & S3H Low Speed Total and Ventilation irflow IRFLOW (FM) 4 3 Total ir ESP Total ir. ESP Vent ir ESP Vent ir. ESP 2 D E F Vent Position Form No. S346- Supersedes S346-9 Page 4 of 6

5 ommercial Room Ventilator Performance Data : RVS- and RVP- IRFLOW (FM) ) F M ( 8 w irflo 4 2 S38H with RVS-,RVP- D E F lade Position Vent ir, ooling/heating Mode Total ir, ooling/heating Mode IRFLOW (FM) ) F M ( 8 w irflo 4 2 S43H with RVS-,RVP- D E F lade Position Vent ir, ooling/heating Mode Total ir, ooling/heating Mode Form No. S346- Supersedes S346-9 Page of 6

6 ommercial Room Ventilator Performance Data : RVS- and RVP- IRFLOW (FM) ) F M ( w 8 irflo 4 2 S49H/S6H with RVS-, RVP- D E F lade Position Vent ir, ooling/heating Mode Total ir, ooling/heating Mode Form No. S346- Supersedes S346-9 Page 6 of 6

7 Performance and pplication Data - WERV-*3 (S26H & S3H) mbient O.D. D/ W F VLT VENTILTION RTE -- 4FM 63% EFFIIENY SUMMER OOLING PERFORMNE (INDOOR DESIGN ONDITIONS 7 D/62 W) VENTILTION RTE % EFFIIENY FM VENTILTION RTE % EFFIIENY VLS VLL HRT HRS HRL VLT VLS VLL HRT HRS HRL VLT VLS VLL HRT HRS HRL FM mbient O.D. D/ F WERV-*3 WINTER HETING PERFORMNE (INDOOR DESIGN ONDITIONS 7 F D) VENTILTION RTE 4 FM 7% EFF. 32 FM 76% EFF. 2 FM 77% EFF. WVL WHR WVL WHR WVL WHR NOTE: Sensible performance only is shown for winter application. LEGEND: VLT = Ventilation Load - Total VLS = Ventilation Load - Sensible VLL = Ventilation Load - Latent HRT = Heat Recovery - Total HRS = Heat Recovery - Sensible HRL = Heat Recovery - Latent WVL = Winter Ventilation Load WHR = Winter Heat Recovery Form No. S346- Supersedes S346-9 Page 7 of 6

8 Performance and pplication Data - WERV-* (S38H, S43H, S49H & S6H) SUMMER OOLING PERFORMNE (INDOOR DESIGN ONDITIONS 7 D/62 W) mbient O.D. VENTILTION RTE -- 4 FM VENTILTION RTE FM VENTILTION RTE -- 3 FM D/ W F VLT VLS VLL HRT HRS HRL VLT VLS VLL HRT HRS HRL VLT VLS VLL HRT HRS HRL mbient O.D. D/ F WERV-* WINTER HETING PERFORMNE (INDOOR DESIGN ONDITIONS 7 F D) VENTILTION RTE 4 FM 37 FM 3 FM WVL WHR WVL WHR WVL WHR NOTE: Sensible performance only is shown for winter application. LEGEND: VLT = Ventilation Load - Total VLS = Ventilation Load - Sensible VLL = Ventilation Load - Latent HRT = Heat Recovery - Total HRS = Heat Recovery - Sensible HRL = Heat Recovery - Latent WVL = Winter Ventilation Load WHR = Winter Heat Recovery Form No. S346- Supersedes S346-9 Page 8 of 6

9 This Page Intentionally Left lank Form No. S346- Supersedes S346-9 Page 9 of 6

10 Electrical Specifications Single ircuit Multiple ircui t Models S26H-, Z Rated Volts, HZ and Phase No. of Field Power ircuits Minimum ircuit mpacity Maximum External Fuse Field Power Ground or ircuit Wire Size Wire Size reaker / S26H-, Z / S26H-, Z S3H-, Z / S3H-, Z / S3H-, Z S38H-, Z Min. ircuit mpacity Max. ircuit Exterior Fuse or rt. kr. 2 Field Power Wire Size3 Ground Wire Size3-8 23/28-- or or or S38H-, Z / S38H-Z S43H-, Z or / or or or S43H-, Z / S43H-Z S49H-, Z or /28-- or or or S49H-, Z / S49H-Z S6H-, Z or /28-- or or or S6H-, Z / S6H-Z These Minimum ircuit mpacity values are to be used for sizing the field power conductors. Refer to the National Electrical ode (latest version), rticle 3 for power conductor sizing. aution: When more than one field power circuit is run through one conduit, the conductors must be derated. Pay special attention to note 8 of Table 3 regarding mpacity djustment Factors when more than three (3) conductors are in a raceway. 2 Maximum size of the time delay fuse or HR type circuit breaker for protection of field wiring conductors. 3 ased on 7 copper wire. ll wiring must conform to the National Electrical ode and all local codes. 4 Maximum KW that can operate with the heat pump on is 4KW. Full heat available during Emergency Heat Mode. Maximum KW that can operate with the heat pump on is KW. Full heat available during Emergency Heat Mode. 6 Maximum KW that can operate with the heat pump on is 9KW. Full heat available during Emergency Heat Mode. IMPORTNT: While this electrical data is presented as a guide, it is important to electrically connect properly sized fuses & conductor wires in accordance with the National Electrical ode & all local codes. Form No. S346- Supersedes S346-9 Page of 6

11 Electrical Specifications Dehumidification Models Single ircuit Multiple ircui t Models Rated Volts, HZ and Phase S26HD, Z 4 23/28-- No. of Field Power ircuits Minimum ircuit mpacity D 4 Maximum External Fuse Field Power Ground or ircuit Wire Size Wire Size reaker D S26HD, Z 23/ S26HD, Z S3HD, Z 4 23/28-- D D 9 D D S3HD, Z 6 S3HD, Z 6 S38HD, Z /28--3 D D Min. ircuit mpacity Max. ircuit Exterior Fuse or rt. kr. 2 Field Power Wire Size3 D 9 6 D8 23/28-- or D or D or S38HD, Z D /28--3 D D 4 6 S38HDZ D D D 28 3 S43HD, Z 34 8 D4 6 D or /28-- D8 or D or D or S43HD, Z D /28--3 D D 4 6 S43HDZ 2 D D D 28 3 S49HD, Z 8 23/28-- S49HD, Z 6 23/ D 2 D 2 D 2 D 2 Ground Wire Size3 IMPORTNT: While this electrical data is presented as a guide, it is important to electrically connect properly sized fuses & conductor wires in accordance with the National Electrical ode & all local codes. Form No. S346- Supersedes S346-9 Page of or or or or D 7 D 7 6 D 7 6 S49HDZ 2 D D D 28 3 S6HD, Z 23/ S6HD, Z 9 23/28--3 D 2 D 2 D 2 D or or or or D 7 6 D 7 6 S6HDZ 6 2 D D 3 3 These Minimum ircuit mpacity values are to be used for sizing the field power conductors. Refer to the National Electrical ode (latest version), rticle 3 for power conductor sizing. aution: When more than one field power circuit is run through one conduit, the conductors must be derated. Pay special attention to note 8 of Table 3 regarding mpacity djustment Factors when more than three (3) conductors are in a raceway. 2 Maximum size of the time delay fuse or HR type circuit breaker for protection of field wiring conductors. 3 ased on 7 copper wire. ll wiring must conform to the National Electrical ode and all local codes. 4 Maximum KW that can operate with the heat pump on is 4KW. Full heat available during Emergency Heat Mode. Maximum KW that can operate with the heat pump on is KW. Full heat available during Emergency Heat Mode. 6 Maximum KW that can operate with the heat pump on is 9KW. Full heat available during Emergency Heat Mode.

12 Indoor lower Performance FM at 23 or 4 Volts ESP in Inches Water olumn S26H, S3H High Speed Dry/Wet oil Low Speed Dry/Wet oil. / 9/9. 9/8 84/8. 2 7/7 7/6 bove data is with " standard disposable or " washable filter For optional 2" pleated filter - reduce ESP by.8 in. Reconnect to next lower speed for free blow (non-ducted) installation. Indoor lower Performance - FM (."." H 2 ) Model ooling Rated Max lower Electric & Heat ESP ESP Only Heat Pump S38H.. S43H.. S49H. 2. S6H. 2. NOTE: These units are equipped with a variable speed (EM) indoor motor that automatically adjusts itself to maintain approximately the same rate of indoor airflow in both heating & cooling, dry & wet coil conditions and at both 23/28 or 4 volts. Maximum ESP (inches W) shown is with 2" thick disposable filter. 2 lower only FM is the total air being circulated during continuous fan mode. 3 FM output on ooling or Electric Heat. Electric Heat Table - Refer to Electrical Specifications for vailability by Unit Model Nominal KW t 24V () t 28V () t 48V (2) t 4V (2) Kw -Ph mps 3-Ph mps tuh , , , , , , , ,2 () These electric heaters are available in 23/28V units only. (2) These electric heaters are available in 48V units only Kw -Ph mps 3-Ph mps tuh 3.. 4, , , , , , , ,9 Kw 3-Ph mps tuh Kw 3-Ph mps tuh , , , , , ,99 Heater Packages - Field Installed for Standard & Dehumidification Models Designed for adding Electric Heat to KW Units ircuit reaker Standard on 23/28V Models Heat Pump Models S26H S3H S38H S43H S49H S6H - Models 23/28- Heater Model # EHSH3-4 EHSH3-8 EHSH3-4 EHSH3-8 EHS3H- EHS3H-8 EHS3H- EHS3H- EHS4H-4 EHS4H- EHS4H-8 EHS4H- EHS4H- EHS4H- EHS4H-8 EHS4H- EHS4H- EHSH- EHSH- EHSH- EHSH-2 ETL US & anada Listed Toggle Disconnect Standard on 4V Models - Models 23/28-3 K W Heater Model # 4 HSH HSH Models 4-3 K W Heater Model # KW E 6 EHSH3-6 6 E 6 EHSH3-6 6 EHSH-6 EHS3H-9 EHS3H- EHSH-6 EHSH-9 EHSH- EHSH-6 EHSH-9 EHSH- EHSH-9 EHSH EHSH-6 EHS3H-9 EHS3H- EHSH-6 EHSH-9 EHSH- EHSH-6 EHSH-9 EHSH- EHSH-9 EHSH Form No. S346- Supersedes S346-9 Page of 6

13 ooling pplication Data - Outdoor Temperature F Model S26H S3H S38H S43H S49H S6H D../W.. 2 7/ 62 8/ 67 8/ 72 7/ 62 8/ 67 8/ 72 7/ 62 8/ 67 8/ 72 7/ 62 8/ 67 8/ 72 7/ 62 8/ 67 8/ 72 7/ 62 8/ 67 8/ 72 ooling apacity 7 F 8 F 8 F 9 F 9 F F F F F 28,9 2,4 3,8 2,7 36,7 2,2 29,7 2,4 3,7 2,7 37,8 2,2 37,8 3, 4,3 29, 48, 3,3 42, 32,8 4,3 3,8 4, 32, 47, 37,3,3 36,2 9,9 37, 7,3 4, 6,2 4,3 72,9 4,3 26, 2,4 29, 2, 33,9 2,3 28,4 2,8 3,9 2,4 36,2 2,7 36, 29,7 39,3 29, 46, 29, 4,2 32,7 44,9 32,, 32, 4,4 36, 49, 3,9 7,9 36, 4,8 4, 9,7 39,8 69,8 4,4 elow 6 F, unit requires a factory or field installed low ambient control. 2 Return air temperature F. 24,8 9, 27, 9,3 3, 9,4 27, 2,4 3, 2,2 34, 2,3 34, 29, 38,3 28,7 44, 28,9 39,7 32,2 44, 3,9,7 32, 43,7 3,9 48, 3,,7 3,7,4 39, 8,2 39,2 66,8 39,4 23, 8,8 26, 8,8 29, 8,7 26, 9,9 29,3 9,9 33, 9,8 32,9 28,2 37,2 28,2 42, 28, 38, 3,7 43, 3,7 48, 3, 4,7 3, 47, 3, 3,2 34,8,2 38, 6,7 38, 64, 38,4 2,8 8,2 2, 8,3 27,8 8, 24,8 9,4 28,4 9, 3, 9,2 3,4 27, 36, 27,8 4, 27,3 36,2 3,9 4, 3,2 46, 3, 39, 34, 46, 34,4, 33,8 47,9 37,, 37,9 6, 37,2 2,8 7,7 24,2 8, 26, 7,4 23,7 8,9 27, 9,2 3,2 8, 3, 26,9 34,9 27,4 38,2 26, 34,2 3, 39,8 3, 43, 29, 37, 33, 43,7 33, 47,8 32, 4,8 36, 3,3 37, 8,3 3,9 apacity irflow Total TUH TUH 2, 7,3 23, 7,7 2, 6,9 22, 8,4 26, 8,8 28,7 7,9 28, 26,3 33, 27, 36,3 2,8 3,9 29, 37, 29,8 4, 28,4 3,2 32, 4, 32,8 44,8 3,3 43,7 3,4, 36,3, 34, 9, 7, 23,3 7, 24,8 6,4 2, 7,8 2,7 8,4 27,4 7,3 27,2 2,8 32,4 26, 34, 2, 29,4 28, 3, 28,9 37,4 27, 32,8 3,9 39, 3,9 4, 29,9 4,7 34,3 49,7 3,4,9 33,2 Factors ate.. 9, 6,8 22,8 7,4 24, 6, 2, 7,3 24,7 8, 26, 6, 2,9 2,2 3, 26,2 32,7 24,2 26,9 26, 32,3 27,7 34, 2, 3,3 29,7 36,4 3,9 38,3 28, 39,7 33, 47,8 34,4,2 3,7 Multiplier % of Rated - R d Sensible.9. Heating pplication Rating & Outdoor Temperature F* Model F F F F 2 F 2 F 3 F 3 F 4 F 4 F F F F TUH 8,8,,2,,3 6,4 7, 8, 2,3 24, 26, 27,8 29, S26H WTTS OP TUH 7,7 9,8,,2 6,2 8,2 2,2 22,2 24, 27, 29,3 3, 33,7 S3H WTTS OP TUH 3,,4 7,8 2, 2,7 22,8 24, 2, 29,2 33,4 36,4 38,8 4, S38H WTTS OP TUH, 6, 9,3 22, 23,7 24,9 26, 27, 32, 37, 4, 43,3 46, S43H WTTS OP TUH,3 8,4 2, 24,8 27, 3, 32,7 3,2 39,3 43,4 46,9, 3,3 S49H WTTS OP TUH 7, 2,2 24,9 28, 3,7 3,7 32,7 33,7 4,4 49, 4,2 7,9 6, S6H WTTS OP * 7 F D indoor return air at rated FM includes defrost operation below 4. Form No. S346- Supersedes S346-9 Page 3 of 6

14 This Page Intentionally Left lank Form No. S346- Supersedes S346-9 Page of 6

15 learances Required for Service ccess and dequate ondenser irflow MODELS LEFT SIDE RIGHT SIDE ll Models 2" 2" Minimum learances Required to ombustible Materials MODELS SUPPLY IR DUT FIRST THREE FEET Refer to the Installation Manual for more detailed information. INET ll Models /4" " Dimensions of asic Unit for rchitectural and Installation Requirements (Nominal) MODEL WIDTH (W) DEPTH HEIGHT (D) (H) SUPPLY RETUR N E F G I J K L M N O P Q R S S2 S26H S3H S38H S43H S49H S6H T ll dimensions are in inches. Dimensional drawings are not to scale. E.7 F W uilt In Rain Hood 4 Pitch Filter ccess Panel Vent Option Door Ventilation ir Heater ccess Panel Electric Heat. reaker/ Disconnect ccess Panel (Lockable) D 2.3 I H Side Wall Mounting rackets (uilt In) Top Rain Flashing Shipping Location Optional Electrical Entrances O.44 Supply ir Opening Return ir Opening R S S S G ondenser ir Outlet Low Voltage Electrical Entrance High Voltage Electrical Entrance ond. ir Inlet J K L M P S2 S2 T Front View Side View Drain N Q ack View ottom Installation racket MIS-2762 FRONT VIEW RIGHT SIDE VIEW K VIEW Form No. S346- Supersedes S346-9 Page of 6

16 Heat Pump Wall-Mount Model Nomenclature S 38 H X X X X X X MODEL NUMER PITY 26-2 Ton 3-2½ Ton 38-3 Ton 43-3½ Ton 49-4 Ton 6 - Ton HET PUMP REVISION SPEILTY PRODUTS 2 (Non-Standard) VOLTS & PHSE - 23/28// - 23/28//3-4//3 KW Z - KW 4-4KW - KW 6-6KW 8-8KW 9-9KW -KW -KW 2-2KW VENTILTION OPTIONS (See Vent Options Table elow) FILTER OPTIONS X - -Inch Fiberglass (MERV 2) H - 2-Inch Pleated (MERV 8) 3 P - 2-Inch Pleated (MERV 6) W - -Inch Washable OUTLET OPTIONS X - Front (Standard) OLOR OPTIONS X - eige - White 4 - uckeye Gray - Desert rown 8 - Dark ronze For KW and circuit breakers (23/28 volt) or toggle disconnect (4V) applications, insert Z in the KW field of the model number. See Pages &. 2 Insert D for dehumidification with hot gas reheat. Reference Form for complete details. 3 Not available for S26H or S3H Models. ONTROL MODULES (See ontrol Module Options) OIL OPTIONS X -Standard - Phenolic oated Evaporator 2 - Phenolic oated ondenser 3 - Phenolic oated Evaporator and ondenser Ventilation Options MODELS S26H, S3H S38H, S43H, S49H, S6H DESRIPTION Factory Installed Field Installed Factory Installed Field Installed ode No. Part No. ode No. Part No. arometric Fresh ir Damper - No Exhaust - Standard X FD-3 X FD- lank-off Plate OP-3 OP- Motorized Fresh ir Damper - No Exhaust M MFD-3 M MFD- ommercial Ventilator - Spring Return w/exhaust V RVS-3 V RVS- ommercial Ventilator - Power Return w/exhaust P RVP-3 P RVP-w/Exhaust Economizer (Internal) - Fully Modulating E EIFM-3 E EIFM- Energy Recovery Ventilator - 23V R ERVF-3 R ERVF- Energy Recovery Ventilator - 4V R ERVF-3 R ERVF- Door Kit for ERVF (Required) N/ WMDK3- N/ WMDK- Intake and exhaust can be independently adjusted. WMDK Door Kit must be ordered in addition to ERVF ssembly and color matched to unit ("X" = eige; "4" = uckeye Gray; "8" = Dark ronze) Heat Pump ontrol Modules DESRIPTION Low Pressure ontrol High Pressure ontrol Low mbient ontrol and Relay 2 Start Kit 3 Start Kit 4 Outdoor Thermostat Factory Installed ode Number Field Installed Number X N/ 23V E MH-2 4V E MH-2 Q MH- 6 R Field Installe d M- 3 Field Installe d SK Field Installe d SK6 = Standard Equipment The high & low pressure controls are auto reset. Operating circuit includes a lockout feature and is resettable from the wall thermostat. ll low pressure controls use a timed bypass circuit to prevent nuisance tripping during low temperature start-up. 2 The low ambient control includes an 82-8 (fan relay) and permits cooling operation down to F. 3 PTR start kit can be used with all - single phase models. Increases starting torque 2-3x. Not used for - or - three phase models. Do not use if SK is used. 4 Start capacitor and potential relay start kit can be used with all - single phase models. Increases starting torque 9x. Not used for - or - three phase models. Do not use if M- is used. The outdoor thermostat is adjustable from F to F. It is suitable for use as a compressor cut-off thermostat. Not available on dehumidification models. Use outdoor sensor input to electronic thermostat. 6 pplies to both 23V and 4V models. NOTE: Standard heat pump control board has a -minute compressor anti-short cycle timer. SK = ll Models except S49H-. SK6 = S49H- only. Part Form No. S346- Supersedes S346-9 Page 6 of 6 ard Manufacturing ompany, Inc. ryan, Ohio Due to our continuous product improvement policy, all specifications subject to change without notice. efore purchasing this appliance, read important energy cost and efficiency information available from your retailer. Form No. S346 May, 2 Supersedes: S346-9

THE WALL-MOUNT 6-TON AIR CONDITIONERS

THE WALL-MOUNT 6-TON AIR CONDITIONERS THE WLL-MOUNT -TON IR CONDITIONERS Model W7 - Right Side Control Panel Model W7L - Left Side Control Panel, Btuh 9.5 EER Hz The Bard Wall-Mount ir Conditioner is a self contained energy efficient system,

More information

GREEN REFRIGERANT R-410A

GREEN REFRIGERANT R-410A THE WLL-MOUNT IR CONDITIONERS -. EER, (HZ) Models W7 to W. to Ton (, to, Btuh) Right Side Control Panel Hz The Bard Wall-Mount ir Conditioner is a self contained energy efficient system, which is designed

More information

THE WALL-MOUNT TM SIX TON AIR CONDITIONER

THE WALL-MOUNT TM SIX TON AIR CONDITIONER The Bard Wall-Mount Six Ton Air Conditioner is a self contained energy efficient system, which is designed to offer maximum indoor comfort at a minimal cost without using valuable indoor floor space or

More information

GREEN REFRIGERANT R-410A

GREEN REFRIGERANT R-410A WALL-MOUNT HEAT PUMPS - (0HZ) Models: JH to J0H 0Hz Heating Capacities:,000 to,000 Capacities:,00 to,000 Solair Wall-Mount Heat Pump is a self-contained energy efficient heating and cooling system, which

More information

GREEN REFRIGERANT R-410A

GREEN REFRIGERANT R-410A PH-SERIES PCKGED HET PUMPS Cooling Capacities: 2, to 6, Heating Capacities:, to 2, SEER:. HSPF: GREEN REFRIGERNT R-4 FRONT (INDOOR IRFLOW) END OF UNIT CK (OUTDOOR IRFLOW) END OF UNIT Standard Engineered

More information

THE WALL-MOUNT QUIET CLIMATE HEAT PUMPS

THE WALL-MOUNT QUIET CLIMATE HEAT PUMPS THE WALL-MOUNT QUIET CLIMATE HEAT PUMPS Models: SH to SH Up to.5 EER Heating Capacities: 2, to, BTUH Cooling Capacities: 2, to 55, BTUH Green Refrigerant R-A The Bard Wall-Mount Heat Pump is a self-contained

More information

THE WALL-MOUNT Quiet Climate A/C 10.0 EER

THE WALL-MOUNT Quiet Climate A/C 10.0 EER THE WALL-MOUNT Quiet Climate A/C. EER Models WA, W9A, WA to Ton (, to, Btuh) Right Side Control Panel Hz GREEN REFRIGERANT R-A The Bard Wall-Mount Air Conditioner is a self contained energy efficient system,

More information

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features THE WALL-MOUNT ONE TON AIR CONDITIONER W2A,800 Btuh 9.00 EER Right Side Control Panel 60Hz GREEN REFRIGERANT R-A The Bard Wall-Mount One Ton Air Conditioner is a self contained energy efficient heating

More information

WALL-MOUNT HEAT PUMPS - (60HZ)

WALL-MOUNT HEAT PUMPS - (60HZ) WALL-MOUNT HEAT PUMPS - (0HZ) Models: JH to J0H 0Hz Heating Capacities:,000 to 5,000 Cooling Capacities:,00 to 5,000 Solair Wall-Mount Heat Pump is a self-contained energy efficient heating and cooling

More information

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features THE WALL-MOUNT ONE TON AIR CONDITIONER W2AAA 2,000 Btuh.00 EER Right Side Control Panel 60Hz Green Refrigerant R-4A The Bard Wall-Mount One Ton Air Conditioner is a self contained energy efficient heating

More information

Q-TEC QC-Series Chilled Water Air Conditioner

Q-TEC QC-Series Chilled Water Air Conditioner Cooling Capacities: 13,3 to 49,3 BTUH (Based on EWT, GPM & CFM) Q-TEC QC-Series Chilled Water Air Conditioner The Q-TEC Series self-contained packaged chilled water air conditioner is designed to be installed

More information

Q-Tec TM QC-Series Chilled Water Air Conditioner

Q-Tec TM QC-Series Chilled Water Air Conditioner Q-Tec TM QC-Series Chilled Water Air Conditioner Cooling Capacities:, to, BTUH (Based on EWT, GPM and ) The Q-Tec Series self-contained packaged chilled water air conditioner is designed to be installed

More information

Green Refrigerant. THE WALL-MOUNT STEP CAPACITY AIR CONDITIONERS Integrated Part Load Value (IPLV) Efficiency Up To 15.3 BTU/WATT. Engineered Features

Green Refrigerant. THE WALL-MOUNT STEP CAPACITY AIR CONDITIONERS Integrated Part Load Value (IPLV) Efficiency Up To 15.3 BTU/WATT. Engineered Features THE WALL-MOUNT STEP CAPACITY AIR CONDITIONERS Integrated Part Load Value (IPLV) Efficiency Up To 5.3 BTU/WATT WA3S WA5S Right Side Control Panel WL3S WL5S Left Side Control Panel 3 to 5 Ton (35,2 to 5,5

More information

THE WALL-MOUNT GAS/ELECTRIC Low NOx Certified Models

THE WALL-MOUNT GAS/ELECTRIC Low NOx Certified Models Models: W24G3 to WG3 Up to 1.5 EER 26, to 57,5 BTUH Cooling Capacity 37, to 74, BTUH Heating Capacity The Bard Wall-Mount Electric Air Conditioner with gas fired heating is a self contained energy efficient

More information

THE WALL-MOUNT HEAT PUMPS EER, (60HZ)

THE WALL-MOUNT HEAT PUMPS EER, (60HZ) THE WALL-MOUNT HEAT PUMPS -. EER, (HZ) Models: Heating Capacities: Cooling Capacities: Engineered Features WHA to WHA Hz (,5 to 5,5 Btuh) (7, to 5, Btuh) The Bard Wall-Mount Heat Pump is a self contained

More information

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed. THE WALL-MOUNT AIR CONDITIONER - 9. EER, (HZ) Model W7A2 Right-ide Control Panel Model W7L2 Left-ide Control Panel Ton (, Btuh) For Export Only The Bard Wall-Mount Air Conditioner is a self contained energy

More information

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed. THE WALL-MOUNT AIR CONDITIONER -. EER, (HZ) Models W7A to W7A Right-ide Control Panel Models W7L to W7L Left-ide Control Panel. to Ton (, to, Btuh) The Bard Wall-Mount Air Conditioner is a self contained

More information

Q-TEC Q24A-Q60A Air Conditioners

Q-TEC Q24A-Q60A Air Conditioners The Q-TEC Series self contained packaged air conditioner is designed to be installed inside a building structure against an exterior exposed wall. Q-TEC s design provides whisper quiet operation with total

More information

The Wall-Mount Step Capacity Gas/Electric - WG*S Series Integrated Part Load Value (IPLV) Efficiency Up to 15.6 BTU/WATT NOx Certified Models

The Wall-Mount Step Capacity Gas/Electric - WG*S Series Integrated Part Load Value (IPLV) Efficiency Up to 15.6 BTU/WATT NOx Certified Models The Wall-Mount Step Capacity Gas/Electric - WG*S Series Integrated Part Load Value (IPLV) Efficiency Up to 15.6 BTU/WATT NOx Certified Models WG3S2, WG4S2, WG5S2 6HZ 24, to 56,5 BTUH Cooling Capacity 37,

More information

Q-TEC Q24H3-Q60H3 Air-to-Air Heat Pump 10 EER Units

Q-TEC Q24H3-Q60H3 Air-to-Air Heat Pump 10 EER Units Heating Capacities: Cooling Capacities: Q-TEC Q2H3-QH3 Air-to-Air Heat Pump 0 EER Units 23,0 to,000 Btuh,000 to 5,0 Btuh The Q-TEC Series self contained packaged heat pump is designed to be installed inside

More information

Q/Tec TM QH-Series 2 Air-to-Air Heat Pumps

Q/Tec TM QH-Series 2 Air-to-Air Heat Pumps Heating Capacities: 2, to 7, BTUH Capacities:, to 2, BTUH The Q/Tec Series self-contained packaged heat pump is designed to be installed inside a building structure against an exterior exposed wall. Q/Tec

More information

THE WALL-MOUNT AIR CONDITIONERS (50HZ)

THE WALL-MOUNT AIR CONDITIONERS (50HZ) THE WALL-MOUNT AIR CONDITIONER (50HZ) Models W24A2 to W70A2 Right ide Control Panel Models W24L2 to W70L2 Left ide Control Panel 2,600 Btuh (6.33 KW) 62,000 Btuh (8.6 KW) For Export Only The Bard Wall-Mount

More information

Q/Tec TM QA-Series Air Conditioners

Q/Tec TM QA-Series Air Conditioners Q/Tec TM QASeries Air Conditioners The Q/Tec series self contained packaged air conditioner is designed to be installed inside a building structure against an exterior exposed wall. Q/Tec s design provides

More information

The Wall-Mount Variable Capacity Environmental Control Units. Green Refrigerant

The Wall-Mount Variable Capacity Environmental Control Units. Green Refrigerant The Wall-Mount Variable Environmental Control Units Bard is an ISO 00:200 Certified Manufacturer, 5 and -Ton Variable ECU Dual /50 Hz Frequency Cooling Op Range -40F to +F ODT The Bard Variable ECU design

More information

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed. THE WALL-MOUNT AIR CONDITIONER -. EER, (HZ) Models WAA to W72AA Right-ide Control Panel Models WLA to W72LA Left-ide Control Panel. to Ton (7, to 7, Btuh) Green Refrigerant R-A The Bard Wall-Mount Air

More information

BARD MANUFACTURING COMPANY, INC. W18AA-W72AB

BARD MANUFACTURING COMPANY, INC. W18AA-W72AB BARD MANUFACTURING COMPANY, INC. W18AA-W72AB Series Right-Side Access Air Conditioner W18LA-W72LB Series Left-Side Access Air Conditioner Engineering Specification Guide 1.0 GENERAL Furnish and install

More information

GREEN REFRIGERANT R-410A

GREEN REFRIGERANT R-410A THE WALLMOUNT STEP CAPACITY AIR CONDITIONERS Integrated Part Load Value (IPLV) Efficiency Up To. BTU/WATT WAS, WAS, WAS to Ton (,0 to,00 Btuh) Right Side Control Panel 0Hz GREEN REFRIGERANT RA The Bard

More information

Q/Tec TM QW-Series Water-to-Air Heat Pumps

Q/Tec TM QW-Series Water-to-Air Heat Pumps Heating Capacities: 6,4 to 45,5 BTUH Capacities:, to 53,5 BTUH : 3. to 3.5 : 3.4 to 6.6 Q/Tec TM QW-Series Water-to-Air Heat Pumps The Q/Tec series self contained packaged water-to-air heat pump is designed

More information

BARD MANUFACTURING COMPANY, INC. WG3S-WG5S 2-Stage Cooling with Gas Heat Engineering Specification Guide

BARD MANUFACTURING COMPANY, INC. WG3S-WG5S 2-Stage Cooling with Gas Heat Engineering Specification Guide BARD MANUFACTURING COMPANY, INC. WG3S-WG5S 2-Stage Cooling with Gas Heat Engineering Specification Guide 1.0 GENERAL Furnish and install a self-contained, vertical, exterior wall mount, electric air conditioner

More information

Wall Mounted Air Conditioners with Gas Heat Models AVGA

Wall Mounted Air Conditioners with Gas Heat Models AVGA PRODUCT DATA SHEET Wall Mounted Air Conditioners with Gas Heat Models AVGA24-30-36-42-48-60 General Description The Marvair GPac wall mounted air conditioner with gas heat is designed for use on a variety

More information

DUAL-TEC WALL-MOUNT Air Conditioners with -48VDC Blower Motor DC Voltage 100% Free Cooling Unit

DUAL-TEC WALL-MOUNT Air Conditioners with -48VDC Blower Motor DC Voltage 100% Free Cooling Unit DUAL-TEC WALL-MOUNT Air Conditioners with -48VDC Blower Motor DC Voltage 100% Free Cooling Unit D35A/L 1-tage Right & Left-Hand Control Panel The Bard DUAL-TEC Wall Mount Air Conditioners with -48VDC Blower

More information

DUAL-TEC WALL-MOUNT Air Conditioners with -48VDC Blower Motor DC Voltage 100% Free Cooling Unit

DUAL-TEC WALL-MOUNT Air Conditioners with -48VDC Blower Motor DC Voltage 100% Free Cooling Unit DUAL-TEC WALL-MOUNT Air Conditioners with -48VDC Blower Motor DC Voltage 100% Free Cooling Unit D36A/L 1-tage Right & Left-Hand Control Panel Green Refrigerant R-410A The Bard DUAL-TEC Wall Mount Air Conditioners

More information

1.5 to 3 Ton 208V to 460V 60hz Air Conditioner Specifications

1.5 to 3 Ton 208V to 460V 60hz Air Conditioner Specifications .5 to 3 Ton 2V to 4V hz Air Conditioner Specifications EER WA Series WALL-MOUNT.5 to 3 Ton V to 4V EER hz AirWA Conditioner Specifications. TM Series WALL-MOUNT Wall-Mount Air Conditioner is a self nergy

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS WA121

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS WA121 INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS Model: WA121 Bard Manufacturing Company Bryan, Ohio 43506 Since 1914...Moving ahead just as planned. Manual : 2100-234 G Supersedes: 2100-234

More information

BARD MANUFACTURING COMPANY, INC. W24G-W60G Gas Heat/Electric Cooling Engineering Specification Guide

BARD MANUFACTURING COMPANY, INC. W24G-W60G Gas Heat/Electric Cooling Engineering Specification Guide BARD MANUFACTURING COMPANY, INC. W24G-W60G Gas Heat/Electric Cooling Engineering Specification Guide 1.0 GENERAL Furnish and install a self-contained, vertical, exterior wall mount, electric air conditioner

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS MODELS WA3 WA42 WA42 WA49 WA2 Bard Manufacturing Company Bryan, Ohio 4350 Since 94...Moving ahead just as planned. Manual : 20-2J Supersedes:

More information

INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST

INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST MODELS: WGERV-A3 WGERV-C3 WGERV-A5 WGERV-C5 BARD MANUFACTURING COMPANY Bryan, Ohio 4356 Since 1914...Moving ahead, just as planned. Manual:

More information

LRP14HP/LRP14DF/LRP14AC/LRP14GE/LRP16GE/LRP16HP SERIES UNITS

LRP14HP/LRP14DF/LRP14AC/LRP14GE/LRP16GE/LRP16HP SERIES UNITS Service Literature orp. 1501-L2 August 2016 Revised March 2017 LRP14HP/DF/A/GE LRP16GE/HP 2 to 5 Ton (7.0 to 17.6 kw) LRP14HP/LRP14DF/LRP14A/LRP14GE/LRP16GE/LRP16HP SERIES UNITS The LRP14/16 series packaged

More information

INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST

INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST Models: WERV-A5 WERV-C5 For Use with Bard 3-1/2 Through 5 Ton Wall Mount Air Conditioners and Heat Pumps Bard Manufacturing

More information

Product Guide. Wallmount. Air Conditioners & Heat Pumps

Product Guide. Wallmount. Air Conditioners & Heat Pumps Product Guide Wallmount Air Conditioners & Heat Pumps Standard Features page 2 All Major Components can be Accessed from the Front 00 Hour Salt Spray rated powder coated baked paint finish AHRI certified

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS MODELS WA3 WA43 WA44 WA49 WA Bard Manufacturing Company Bryan, Ohio 4350 Since 94...Moving ahead just as planned. Manual : 0-39 Supersedes:

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

ComPac I & ComPac II 1 to 6 Ton Vertical Wall Mount Air Conditioners Models AVP

ComPac I & ComPac II 1 to 6 Ton Vertical Wall Mount Air Conditioners Models AVP MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH R EQUIPMENT ARI STANDARD 210 ARI STANDARDS ComPac I & ComPac II 1 to 6 Ton Vertical Wall Mount Air Conditioners Models AVP12-20-24-30-36-42-48-60-72 General

More information

EC MODEL. EC Model & Split Systems Water Source Heat Pump. 6 to 30 tons

EC MODEL. EC Model & Split Systems Water Source Heat Pump. 6 to 30 tons E & Split Systems Water Source Heat Pump 6 to 30 tons The E, including Split Systems, provides the best combination of performance, comfort and one-of-a-kind features that satisfy the high demands of any

More information

1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA

1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA PRODUCT DATA SHEET 1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60 General Description The Marvair ModPac air conditioner is a cost-effective vertical, wall mounted air

More information

Outstanding Performance; Application Flexibility

Outstanding Performance; Application Flexibility PORTLE HILLER4EP2 SERIES Outstanding Performance; pplication Flexibility EP2 Series Portable hillers are designed for 4 to 43 ton applications. Units are available in air-cooled, water-cooled and remote

More information

Installation Instructions

Installation Instructions Installation Instructions Wall Mounted Packaged Air Conditioner Models: WA8, WA24 MIS-656 Bard Manufacturing Company Bryan, Ohio 43506 Since 94...Moving ahead, just as planned. Manual No.: 20-200K Supersedes:

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMP WH184 WH242

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMP WH184 WH242 INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMP Models WH84 WH242 Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since 94...Moving ahead just as planned. Manual : 200-423C Supersedes: 200-423B

More information

9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners

9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners PRODUCT DATA SHEET 9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60 General Description The Eubank WalPac A/C 9 air conditioner is a cost-effective vertical,

More information

I-TEC I30A1D-I60A1D 2-Stage Compressor High Efficiency Air Source Air Conditioners w/dehumidification

I-TEC I30A1D-I60A1D 2-Stage Compressor High Efficiency Air Source Air Conditioners w/dehumidification I-TEC I30AD-IAD 2-Stage Compressor High Efficiency Air Source Air Conditioners w/dehumidification Cooling Capacities: 20,0 to 54,000 Btuh The Bard I-TEC Air Conditioner system is designed for classrooms

More information

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw) High Ambient / High Efficiency Series R - 410a 50Hz Ducted Split Air Conditioners (5.0 kw - 17.5 kw) ISO 9001 : 2008 ISO 14001 : 2004 ISO 18001 : 2007 R - 410a 50Hz Introduction: Established in the year

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS WH381 WH431 WH491

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS WH381 WH431 WH491 INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS Models WH3 WH43 WH49 Bard Manufacturing Company, Inc. Bryan, Ohio 436 Since 94...Moving ahead just as planned. Manual : 20-342I Supersedes: 20-342H

More information

INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST MODELS: WFERV. Bard Manufacturing Company, Inc.

INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST MODELS: WFERV. Bard Manufacturing Company, Inc. INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST MODELS: WFERV Bard Manufacturing Company, Inc. Bryan, Ohio 4356 Since 1914...Moving ahead, just as planned. Manual: 21-495 Supersedes:

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL WALL-MOUNTED PACKAGED AIR CONDITIONER HA-A HL-A Models: H6A-A H6L-A Description Page Cabinet Components HA-A, H6A-A Exploded View... Usage List HA-A... Usage List H6A-A... Cabinet

More information

THE MULTI-TEC WALL-MOUNT AIR CONDITIONERS 10 EER (50 HZ) WITH LOGIC BOARD

THE MULTI-TEC WALL-MOUNT AIR CONDITIONERS 10 EER (50 HZ) WITH LOGIC BOARD The MULTI-TEC Wall-Mount Air Conditioner utilizes PLC (Programmable Logic Control) technology to allow multiple units to operate connected to a single LC6000 controller. When installed with an optional

More information

Green Refrigerant. MULTI-TEC WALL-MOUNT Features All Models. Standard Features All Models

Green Refrigerant. MULTI-TEC WALL-MOUNT Features All Models. Standard Features All Models The MULTI-TEC Wall-Mount Air Conditioner utilizes PLC (Programmable Logic Control) technology to allow multiple units to operate connected to a single LC00 controller. When installed with an optional 0%

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS Single Package Rooftop, High---Efficiency Heat Pump Units With Field---Installed Electric Heat Sizes 08 --- 14 with Puron R (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS

More information

62DA,DB,DC,DD,DE,DF07-38

62DA,DB,DC,DD,DE,DF07-38 62D-3SB 62DA,DB,DC,DD,DE,DF07-38 DEDICATED VERTICAL OR HORIZONTAL 100% OUTDOOR AIR UNIT PERFORMANCE DATA UNIT DIMENSION PRINTS ACCESSORY DIMENSION PRINTS Copyright 2011 Carrier Corporation Syracuse, New

More information

Product Data. Fig. 1 - Unit 50VR -A

Product Data. Fig. 1 - Unit 50VR -A 50VR---A Performancet 15 SEER 2---Stage Packaged Heat Pump tem with PuronR (R---410A) Refrigerant Single and Three Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50VR -A A09033 Single-Packaged

More information

OPERATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST. For Use With Bard 2 Through 5 Ton QW*S Series

OPERATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST. For Use With Bard 2 Through 5 Ton QW*S Series OPERATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST Models: 90-09 QWSERV with Occupied Air Capabilities For Use With Bard Through Ton QW*S Series Bard Manufacturing Company, Inc. Bryan, Ohio

More information

Classic 13 Heat Pumps High Efficiency Vertical Packaged Heat Pumps Models HVPA and HVPSA

Classic 13 Heat Pumps High Efficiency Vertical Packaged Heat Pumps Models HVPA and HVPSA Classic 13 Heat Pumps High Efficiency Vertical Packaged Heat Pumps Models HVPA24-30-36-42-49-60 and HVPSA36-42-49-60 General Description HIGH EFFICIENCY - The Marvair Classic 13 High Efficiency Series

More information

GreenPac & GreenPac HGR Heat Pumps & Air Conditioners Models AVP

GreenPac & GreenPac HGR Heat Pumps & Air Conditioners Models AVP MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH R EQUIPMENT ARI STANDARD 210 ARI STANDARDS GreenPac & GreenPac HGR Heat Pumps & Air Conditioners Models AVP24-30-36-42-48-60 General Description The Marvair

More information

OPERATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST. For Use With Bard 2 Through 5 Ton QW*S Series

OPERATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST. For Use With Bard 2 Through 5 Ton QW*S Series OPERATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST Models: 90-007 QWSERV 90-08 QWSERV with Intelligent Defrost For Use With Bard Through 5 Ton QW*S Series Bard Manufacturing Company, Inc. Bryan,

More information

INSTALLATION INSTRUCTIONS ERVR-A3D-X ERVR-C3D-X RETROFIT ENERGY RECOVERY VENTILATOR

INSTALLATION INSTRUCTIONS ERVR-A3D-X ERVR-C3D-X RETROFIT ENERGY RECOVERY VENTILATOR INSTALLATION INSTRUCTIONS Models: ERVR-A3D-X ERVR-C3D-X RETROFIT ENERGY RECOVERY VENTILATOR For Use with Bard 2 Thru 5 Ton "P" Series Air Conditioners and Heat Pumps Bard Manufacturing Company, Inc. Bryan,

More information

WZT High Efficiency Air to Water Split System Heat Pumps With E.V.I. Compressors

WZT High Efficiency Air to Water Split System Heat Pumps With E.V.I. Compressors High Efficiency ir to Water Split System Heat Pumps With E.V.I. ompressors -20 +43 +65 HP E.V.I..O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor

More information

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST. For Use with Bard 3-1/2 thru 5 Ton Wall Mount Air Conditioners and Heat Pumps

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST. For Use with Bard 3-1/2 thru 5 Ton Wall Mount Air Conditioners and Heat Pumps INSTLLTION INSTRUTIONS OMMRIL ROOM VNTILTORS WITH XHUST MOL RV-5 For Use with ard 3-1/2 thru 5 Ton Wall Mount ir onditioners and Heat Pumps ard Manufacturing ompany ryan, Ohio 43506 Since 1914...Moving

More information

INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST MODELS: WGERV-A3A WGERV-C3A WGERV-A5A WGERV-C5A WGSERV-A5 WGSERV-C5

INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST MODELS: WGERV-A3A WGERV-C3A WGERV-A5A WGERV-C5A WGSERV-A5 WGSERV-C5 INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST MODELS: WGERV-A3A WGERV-C3A WGERV-A5A WGERV-C5A WGSERV-A5 WGSERV-C5 Bard Manufacturing Company, Inc. Bryan, Ohio 4356 Since 1914...Moving

More information

INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST

INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST Models: WERV-A2B WERV-A3C WERV-C2B WERV-C3C For Use With Bard 1-1/2 Through 3 Ton Wall Mount Air Conditioners and Heat Pumps

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMP WH184 WH242

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMP WH184 WH242 INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMP Models WH184 WH242 Bard Manufacturing Company Bryan, Ohio 43506 Since 1914...Moving ahead just as planned. Manual : 2100-423A Supersedes: 2100-423

More information

48PGD/E/F/L/M/N PG20-28

48PGD/E/F/L/M/N PG20-28 48/50PG-10SB 48PGD/E/F/L/M/N20-28 50PG20-28 SINGLE-PACKAGE COOLING UNITS WITH FACTORY-INSTALLED GAS HEAT SINGLE-PACKAGE COOLING UNITS WITH OPTIONAL ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINTS

More information

General Description. Operation

General Description. Operation ECUA12ACA & ECUA18ACA SlimPac (1 & 1.5 Ton) Environmental Control Units General Description The Industrial Climate Engineering SlimPac line of Environmental Control Units (ECU) are designed for the telecommunication

More information

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER DCC Series Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS AutoZone R Model Single Package Rooftop Gas Heating/Electric Cooling Unit Size 07 with Puronr (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION

More information

HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, , 18, 20, and 25 NOMINAL TONS

HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, , 18, 20, and 25 NOMINAL TONS HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, 300 15, 18, 20, and 25 NOMINAL TONS COMMERCIAL ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS ELECTRIC HEATING/ELECTRIC COOLING UNITS

More information

General Description. Safety Listed

General Description. Safety Listed ECUA90/120/150/180/240 & ECUDA180/240/300/360 (7.5, 10, 12.5, 15, 20, 25 & 30 Ton) Vertical Wall Mount Air Conditioners General Description Industrial Climate Engineering s air conditioners are used primarily

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS W12A2-A W12A1-K

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS W12A2-A W12A1-K INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS Model: W12A2-A W12A1-K Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since 1914...Moving ahead just as planned. Manual: 2100-509E Supersedes:

More information

General Description. Safety Listed

General Description. Safety Listed ECUA90/120/150/180/240 & ECUDA180/240/300/360 (7.5, 10, 12.5, 15, 20, 25 & 30 Ton) Vertical Wall Mount Air Conditioners General Description Industrial Climate Engineering s air conditioners are used primarily

More information

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON 7D- -A EVOLUTIONr 15 SEER SINGLE-PACKAGED HEAT PUMP SYSTEM WITH PURONr (R-410A) REFRIGERANT SINGLE PHASE 2-5 NOMINAL TONS (SIZES 24-) Fig. 1 - Unit 7D - -A Product Data A09032 Single-Packaged Products

More information

LZT LZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSION ACCESSORIES

LZT LZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSION ACCESSORIES High efficiency air to water heat pumps with E.V.I. compressors -15 +63 E.V.I..O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS 016---028 Single---Package Cooling Units with Factory---Installed Optional Electric Heat Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION

More information

INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST

INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST Models: WERV-A5 WERV-C5 For Use With Bard 3-1/2 through 5 Ton Wall Mount Air Conditioners and Heat Pumps Bard Manufacturing

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS WH421 WH483 WH602

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS WH421 WH483 WH602 INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS MODELS: WH42 WH43 WH2 BARD MANUFACTURING COMPANY Bryan, Ohio 4350 Since 94...Moving ahead, just as planned. Manual: 20-399 Supersedes: File: Volume

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-193 REV. 3 Supersedes Form No. A22-193 Rev. 2 Commercial High-Efficiency Condensing Units 15 & 20 TON MODEL [52.8 & 70.3 kw] 10 & 12.5 TON MODEL [35.2 & 44.0 kw] 10 THROUGH 20 NOMINAL TON

More information

50TM COMBINATION HEATING/COOLING UNITS

50TM COMBINATION HEATING/COOLING UNITS 50TM-1SB 50TM004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York 13221 Form

More information

INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST

INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST Models: ERVF-A3 ERVF-C3 For Use With Bard 2-1/2 through 3 Ton Wall Mount Air Conditioners and Heat Pumps Bard Manufacturing

More information

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners DCC Series Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER

More information

LZT High efficiency air to water heat pumps with E.V.I. compressors

LZT High efficiency air to water heat pumps with E.V.I. compressors High efficiency air to water heat pumps with E.V.I. compressors -20 +43 +65 E.V.I..O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-194 REV. 2 Supersedes Form No. A22-194 Rev. 1 Commercial High-Efficiency Condensing Units RAWL High Efficiency 6.5 & 7.5 TON MODEL [22.86 & 26.38 kw] TABLE OF CONTENTS Model Number Designation...2

More information

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat SINGLE PACKAGE ROOFTOP, GAS HEATING/ELECTRIC COOLING UNIT WITH PURON R (R-410A) REFRIGERANT ONE STAGE COOLING CAPACITY CONTROL: SIZES 08-12 TWO STAGE COOLING CAPACITY CONTROL: SIZES 08, 12 & 14 Submittal

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS INSTLLTION INSTRUCTIONS WLL MOUNTED PCKGE HET PUMPS Models SH261 SH311 Bard Manufacturing Company Bryan, Ohio 43506 Since 1914...Moving ahead just as planned. Manual : 2100-409 Supersedes: 2100-409 File:

More information

GreenPac & GreenPac HGR Air Conditioners Single stage models AVPA and HVEA and 2-stage models HVESA

GreenPac & GreenPac HGR Air Conditioners Single stage models AVPA and HVEA and 2-stage models HVESA General Description The Marvair GreenPac and GreenPac HGR (Hot Gas Reheat) air conditioners are complete, factory assembled wall-mounted systems designed to provide total comfort while meeting ventilation

More information

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: DCC Commercial 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling

More information

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog H3/V3 Series Horizontal and Vertical Indoor Air Handling Units Engineering Catalog Table of Contents AAON H3/V3 Series Features and Options Introduction... 6 H3/V3 Base Model Description... 7 Unit Size...

More information

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons Product Data OMNIZONE 50BRN,BZN006-024 Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems 5 to 20 Nominal Tons The 50BRN,BZN water-cooled and remote air-cooled indoor, self-contained units

More information

PAJ3. Product Specifications

PAJ3. Product Specifications 13 SEER, R 410A PACKAGE AIR CONDITIONER FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz BUILT TO LAST, EASY TO INSTALL AND SERVICE Compact,

More information

WHA WHA. Ground source water to water heat pumps A ++ A ++ Versions

WHA WHA. Ground source water to water heat pumps A ++ A ++ Versions WH ++ ++ +60 82 WH Ground source water to water heat pumps WH heat pumps are particularly suitable for applications that utilise ground source probes.these units have been designed for use with radiant

More information

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION PRODUCT SPECIFICATIONS PACKAGED HEAT PUMPS 3HPP / rhp3 Rooftop Units 60HZ Bulletin No. 0634 October 04 Supersedes October 0 MODEL NUMBER IDENTIFICATION -PHASE MODELS Nominal SEER (3HPP Shown) Unit Type

More information

50TM TFF COMBINATION HEATING/COOLING UNITS

50TM TFF COMBINATION HEATING/COOLING UNITS 50T-1SB 50TM007-012 50TFF004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York

More information

INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST

INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST Models: ERVF-A2 ERVF-C2 For Use With Bard 1-1/2 Through 2 Ton Wall Mount Air Conditioners and Heat Pumps Bard Manufacturing

More information

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT 50HJQ-11SB 50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION

More information