PRODUCT INFORMATION (*) Y cooling Y Warmer (if designated) N heating Y Colder (if designated)
|
|
- Sydney White
- 5 years ago
- Views:
Transcription
1
2
3
4 PRODUCT IFORMATIO (*) IDOOR MODEL PEAD-RP60JALQ PACKAGED AIR CODITIOER OUTDOOR MODEL SUZ-KA60VA3 If function includes heating: Indicate the heating season the Function (indicate if present) information relates to. Indicated values should relate to one heating season at a time. Include at least the heating season Average (mandatory) cooling Warmer (if designated) heating Colder (if designated) Item symbol value unit Item symbol value unit Design load Seasonal efficiency cooling Pdesignc 5,7 kw cooling SEER 5,3 - heating/average Pdesignh 4,5 kw heating/average SCOP/A 3,9 - heating/warmer Pdesignh x kw heating/warmer SCOP/W x - heating/colder Pdesignh x kw heating/colder SCOP/C x - Declared capacity for cooling, at indoor temperature 27(19) Declared energy efficiency ratio, at indoor temperature 27(19) and outdoor temperature Tj and outdoor temperature Tj Tj=35 Pdc 5,7 kw Tj=35 EERd 3,5 - Tj=30 Pdc 4,2 kw Tj=30 EERd 4,7 - Tj=25 Pdc 3,2 kw Tj=25 EERd 7,4 - Tj=20 Pdc 3,0 kw Tj=20 EERd 9,5 - Declared capacity for heating/average season, at indoor Declared coefficient of performance/average season, at indoor Tj=-7 Pdh 3,9 kw Tj=-7 COPd 2,9 - Tj=2 Pdh 2,4 kw Tj=2 COPd 3,7 - Tj=7 Pdh 2,4 kw Tj=7 COPd 5,4 - Tj=12 Pdh 2,7 kw Tj=12 COPd 6,0 - Tj=bivalent temperature Pdh 3,9 kw Tj=bivalent temperature COPd 2,9 - Tj=operating limit Pdh 3,9 kw Tj=operating limit COPd 1,4 - Declared capacity for heating/warmer season, at indoor temperature 20 and outdoor temperature Tj Declared coefficient of performance/warmer season, at indoor Tj=2 Pdh x kw Tj=2 COPd x - Tj=7 Pdh x kw Tj=7 COPd x - Tj=12 Pdh x kw Tj=12 COPd x - Tj=bivalent temperature Pdh x kw Tj=bivalent temperature COPd x - Tj=operating limit Pdh x kw Tj=operating limit COPd x - Declared capacity for heating/colder season, at indoor temperature 20 and outdoor temperature Tj Declared coefficient of performance/colder season, at indoor Tj=-7 Pdh x kw Tj=-7 COPd x - Tj=2 Pdh x kw Tj=2 COPd x - Tj=7 Pdh x kw Tj=7 COPd x - Tj=12 Pdh x kw Tj=12 COPd x - Tj=bivalent temperature Pdh x kw Tj=bivalent temperature COPd x - Tj=operating limit Pdh x kw Tj=operating limit COPd x - Tj=-15 Pdh x kw Tj=-15 COPd x - Bivalent temperature Operating limit temperature heating/average Tbiv -7 heating/average Tol -10 heating/warmer Tbiv x heating/warmer Tol x heating/colder Tbiv x heating/colder Tol x Cycling interval capacity Cycling interval efficiency for cooling Pcycc x kw for cooling EERcyc x - for heating Pcych x kw for heating COPcyc x - Degradation co-efficient cooling Cdc 0,25 - Degradion co-efficient heating Cdh 0,25 - Electric power input in power modes other than 'active mode' Annual electricity consumption off mode POFF 13 W cooling QCE 378 kwh/a standby mode PSB 13 W heating/average QHE 1648 kwh/a thermostat - off mode PTO(c/h) 115/53 W heating/warmer QHE x kwh/a crankcase heater mode PCK 0 W heating/colder QHE x kwh/a Capacity control (indicate one of three options) fixed Other items Sound power level (indoor/outdoor) LWA 55/65 db(a) staged Global warming potential GWP 1975 kgco2eq. variable Rated air flow (indoor/outdoor) /2454 m3/h Contact details for obtaining more information MITSUBISHI ELECTRIC CORPORATIO SHIZUOKA WORKS , Oshika, Suruga-ku, Shizuoka , Japan melshierp@nb.mitsubishielectric.co.jp (*) This information is based on the "product information requirement" in COMMISSIO REGULATIO (EU) o206/2012.
5 TECHICAL DOCUMETATIO ( 1 ) IDOOR MODEL PEAD-RP60JALQ 250H1100W732D (mm) PACKAGED AIR CODITIOER OUTDOOR MODEL SUZ-KA60VA3 880H840W330D (mm) Function cooling heating The heating season Average (mandatory) Warmer (if designated) Colder (if designated) Capacity control fixed staged variable Item Seasonal efficiency ( 2 ) symbol value unit cooling SEER 5,3 - heating/average SCOP/A 3,9 - heating/warmer SCOP/W x - heating/colder SCOP/C x - Energy efficiency class cooling SEER A - heating/average SCOP/A A - heating/warmer SCOP/W x - heating/colder SCOP/C x - Other items Sound power level (indoor/outdoor) LWA 55/65 db(a) Refrigerant - R410A - Global warming potential GWP 1975 kgco2eq. (1) This information is based on COMMISSIO DELEGATED REGULATIO (EU)o626/2011. (2) SEER/SCOP values are measured based on FprE 14825:2011: Testing and rating at part load conditions and calculation of seasonal performance.
BH79B928H01_print_outline.pdf 2013/09/30 14:10:38 CMY
BH79B928H01_print_outline.pdf 2013/09/30 14:10:38 C M CM M C CM K PRODUCT IFORMATIO (*) ROOM AIR CODITIOER IDOOR MODEL 1/2/3 MSZ-EF18VE / MSZ-EF25VE / - IDOOR MODEL 4/5/6 - / - / - OUTDOOR MODEL MXZ-2D42VA
More informationSG79V571H02_print outline.pdf 2012/10/23 17:32:06 CMY
SG79V571H02_print outline.pdf 2012/10/23 17:32:06 C M CM M C CM K PRODUCT IFORMATIO (*) IDOOR MODEL 1/2/3 MSZ-EF18VE / MSZ-EF18VE / MSZ-EF18VE ROOM AIR CODITIOER IDOOR MODEL 4/5/6 - / - / - OUTDOOR MODEL
More informationPRODUCT INFORMATION (*) Y cooling Y Warmer (if designated) N heating Y Colder (if designated)
PRODUCT IFORMATIO (*) IDOOR MODEL PKA-RP100KAL PACKAGED AIR CODITIOER OUTDOOR MODEL PUHZ-ZRP100VKA If function includes heating: Indicate the heating season the Function (indicate if present) information
More informationCOMMISSION REGULATION (EU)
10.3.2012 Official Journal of the European Union L 72/7 COMMISSION REGULATION (EU) No 206/2012 of 6 March 2012 implementing Directive 2009/125/EC of the European Parliament and of the Council with regard
More informationThe test items passed the test specification(s).
Report NO.: NTRE20170442 Test Report No.: NTRE20170442 age 1 of 17 Applicant Name: Test item: Gree Electric Appliances Inc. of Zhuhai West Jinji Rd, Qianshan, Zhuhai, Guangdong, China, 519070 Split Air
More informationWPL 17 IKCS classic 55 C 35 C A ++ A ++ A ++ A + A B C D E F G kw kw. 50 db. 44 db
55 C 35 C A A A B C D E F G A A 50 db 13 7 4 kw 13 9 5 kw 44 db 2015 811/2013 Product datasheet: Room heater to regulation (EU) no. 811/2013 Energy efficiency class for central heating in moderate climates
More informationWPL C 35 C A ++ A + A B C D E F G A + A kw kw. 69 db
55 C 35 C A B C D E F G 33 33 32 kw 32 31 30 kw 69 db 2015 811/2013 Product datasheet: Room heater to regulation (EU) no. 811/2013 Energy efficiency class for central heating in moderate climates for medium
More informationWPL 23 E 55 C 35 C A ++ A + A B C D E F G A + A kw kw. 58 db. 65 db
55 C 35 C A A A B C D E F G A A 58 db 20 18 16 kw 18 17 16 kw 65 db 2015 811/2013 Energy efficiency class for central heating in moderate climates for medium Energy efficiency class for central heating
More information103776HV1241 NOVELAN LAV 8-HV kw kw db 50 db
NOVELAN 44 50 103776HV1241 5 7 6 7 6 4 NOVELAN 103776HV1241 package (heat pumps and combination heater with heat pump) Seasonal space heating energy efficiency of heat pump (ηs) of the heat pump (Prated
More informationDESIGN & TECHNICAL MANUAL
DTW_1SP005E_01 DESIGN & TECHNICAL MANUAL Comfort series ( Single phase type ) INNOVATIVE SOLUTION OF DOMESTIC HEATING Air to Water Split type 111OUTDOOR UNIT CONTENTS SINGLE PHASE TYPE : WO A060LFCA, WO
More informationReport Reference No...:
TEST REORT COMMISSION REGULATION (EU) No 206/2012 of 6 March 2012 implementing Directive 2009/125/EC of the European arliament and of the Council with regard to ecodesign requirements for air conditioners
More informationTECHNICAL MANUAL. INVERTER MULTI-SPLIT SYSTEM RESIDENTIAL AIR-CONDITIONERS (Split system, air to air heat pump type)
Manual No.'14 SCM-T-167 updated November 27, 2014 TECHNICL MNUL INVERTER MULTI-SPLIT SYSTEM RESIDENTIL IR-CONDITIONERS (Split system, air to air heat pump type) (OUTDOOR UNIT) SCM40ZM-S 45ZM-S 50ZM-S 60ZM-S
More informationAir Conditioning Technical Data AZAS-MY1
Air Conditioning Technical Data AZAS-MY1 Outdoor Unit AZAS-MY1 TABLE OF CONTENTS AZAS-MY1 1 Features............................................................. 2 2 Specifications.......................................................
More informationPRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.
PRODUCT DATA COMPACT P - SERIES BY NILAN Domestic Passive heat recovery Active heat recovery Ventilation < 00 m /h Comfort heating Comfort cooling Sanitary hot water production Heating THE VENTILATION
More informationWPC 10 A ++ A + A B C D E F G A B C D E F G. 13 kw. 10 kw. 48 db /2013
WP 10 13 kw 10 kw 48 d 10 kw 2015 811/2013 Product datasheet: omposite system consisting of room heater and temperature controller to regulation (U) no. 811/2013 nergy efficiency class for central heating
More informationHeating Nom. dba 50 (5) 50 (5) 50 (5) Cooling Nom. dba 50 (5) 50 (5) 50 (5) Anti freeze heater (optional) W Expansion vessel Volume l 6 6 6
EWYQ005ADVP EWYQ006ADVP EWYQ007ADVP Sound pressure level Heating Nom. dba 50 (5) 50 (5) 50 (5) Cooling Nom. dba 50 (5) 50 (5) 50 (5) Hydraulic components Anti freeze heater (optional) W 75 75 75 Expansion
More informationLWZ 8 CS Premium A ++ A + A B C D E F G A B C D E F G. 14 kw. 10 kw. 9 kw. 50 db /2013
LWZ 8 S Premium 14 kw 10 kw 50 d 9 kw 50 d 2015 811/2013 Product datasheet: omposite system consisting of room heater and temperature controller to regulation (U) no. 811/2013 nergy efficiency class for
More informationDelegated Regulation (EU) 626/2011 of 4 May 2011 supplementing Directive 2010/30/EU with regard to energy labelling of air conditioners
Delegated Regulation (EU) 626/2011 of 4 May 2011 supplementing Directive 2010/30/EU with regard to energy labelling of air conditioners Incorporated and adapted by Ministerial Council Decision 2011/03/MC-EnC
More informationTeknik Data NIBE F2120 8, 12, 16, 20
Teknik Data NIBE F21, 12, 1, Havadan Suya Isı Pompası LEK F21 F21 Teknik Data Ebatlar F21 Ø2 30 0 0 0 1 10 F2112, 1, Ø2 10 1 0 0 0 1 12 1 LEK Ses basıncı seviyeleri F21 is usually placed next to a house
More informationModel and/or type reference... : COPMAX GS 15 JORDVARMEPUMPE Rating(s)... : V 3N~; 50Hz; other rating refer to page 6
age 2 of 42 Test sample.....: Type of test object... : Trademark... : Heat ump Heat ump Hiseer Model and/or type reference... : COMAX GS 15 JORDVARMEUME Rating(s)... : 380-415 V 3N~; 50Hz; other rating
More informationOfficial Journal of the European Union L 239/1. (Non-legislative acts) REGULATIONS
6.9.2013 Official Journal of the European Union L 239/1 II (Non-legislative acts) REGULATIONS COMMISSION DELEGATED REGULATION (EU) No 811/2013 of 18 February 2013 supplementing Directive 2010/30/EU of
More informationAS10S-DPNHE. Rating(s)... : V 3N~; 50Hz; other rating refer to page 6. Guangzhou Hiseer Air conditioning Co,. LTD
age 2 of 42 Test sample.....: Type of test object... : Trademark... : Model and/or type reference... : Heat ump Heat ump Hiseer AS10S-DNHE Rating(s)... : 380-415 V 3N~; 50Hz; other rating refer to page
More informationPage 2 of 42 Test report no. HS Rev.00
age 2 of 42 Test sample.....: Type of test object... : Trademark... : Heat ump Heat ump Hiseer Model and/or type reference... : AS14S-DNHE Rating(s)... : 380-415 V 3N~; 50Hz; other rating refer to page
More informationDESIGN & TECHNICAL MANUAL
DTW_1SP006E_01 DESIGN & TECHNICAL MANUAL High power series ( Single phase type ) INNOVATIVE SOLUTION OF DOMESTIC HEATING Air to Water Split type 111OUTDOOR UNIT CONTENTS SINGLE PHASE TYPE : WO G112LCTA,
More informationPRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.
PRODUCT DATA COMPACT P - SERIES BY NILAN Domestic Passive heat recovery Active heat recovery Ventilation < 300 m 3 /h Comfort heating Comfort cooling Sanitary hot water production Heating THE VENTILATION
More information2. HYDRAULIC UNIT. COMFORT SERIES_Single phase type: WG A050DG WG A100DG HIGH POWER SERIES: WG G140DG WGYK160DG9
2. HYDRAULIC UNIT COMFORT SERIES_Single phase type: WG A050DG WG A100DG HIGH POWER SERIES: WG G140DG WGYK160DG9 DTW_SDI003E_01--CHAPTER02 2015.02.18 CONTENTS HYDRAULIC UNIT WG 050-160DG 222HYDRAULIC UNIT
More informationi-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:
ABOUT THE i-chiller RANGE The fully packaged, EcoDesign compliant, air-cooled i-chiller range is designed specifically for reliable and efficient process cooling. The unique evaporator is immersed within
More informationDRAFT ECODESIGN REGULATION FOR ENER LOT21 PRODUCTS
Date : 09/09/2013 revised 26/09/2013 Auteur : MMT Destinataires pour action : UNICLIMA Document de travail DRAFT ECODESIGN REGULATION FOR ENER LOT21 PRODUCTS The document exclusively includes technical
More informationHEAT PUMPS MAGIS PRO ErP
HEAT PUMPS MAGIS PRO ErP Split single-phase inverter reversible air-water heat pumps with outdoor condensing unit and hydronic module INDEX MAIN INDEX 1 MAGIS PRO 5-8 - 10 ErP FEATURES (MONO-PHASE)...5
More informationPART I ENERGY EFFICIENCY ACQUIS / DELEGATED REGULATION (EU) 811/2013
Delegated Regulation (EU) 811/2013 of 18 February 2013 supplementing Directive 2010/30/EU with regard to the energy labelling of space heaters, combination heaters, packages of space heater, temperature
More informationAir / Water Heat Pump - Compact Design Modulating 8 18 kw
Air Ground Water Air / Water Heat Pump - Compact Design Modulating 8 18 kw Heliotherm Sensor Comfort Compact A modulating air / water heat pump in compact design for outdoor installation for generous sized
More informationHEAT PUMPS SiOS SYSTEM TERMINAL UNITS UNICO FIXED AIR CONDITIONERS PORTABLE AIR CONDITIONER AIR COOLER VMC DEHUMIDIFIERS HUMIDIFIERS
136 PORTABLE AIR FIXED AIR UNICO AIR COOLER SYSTEM TERMINAL UNITS HEAT PUMPS SiOS FIXED AIR S 137 PELLET STOVES GAS STOVES VMC DEHUMIDIFIERS HUMIDIFIERS FAN HEATERS CERAMIC FAN HEATERS PERSONAL COMFORT
More informationHEAT PUMPS SiOS SYSTEM TERMINAL UNITS UNICO CONDITIONER FIXED AIR PORTABLE AIR CONDITIONER AIR COOLER DEHUMIDIFIERS HUMIDIFIERS FAN HEATERS GAS STOVES
PERSONAL COMFORT 109 THE RANGE The air conditioner without outdoor unit, patented and designed by Olimpia Splendid in 1998. Unico, born with 15 years of experience. A complete range of solutions with no
More informationCOMMISSION REGULATION (EU) No /.. of XXX
EUROPEAN COMMISSION Brussels, XXX [ ](2013) XXX draft COMMISSION REGULATION (EU) No /.. of XXX implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign
More informationMSZ-L SERIESES. Luminous and Luxurious Design
MSZ-LN25/35/50/60VGR MSZ-L SERIESES Developed to complement modern interior room décor, the LN Series is available in four colours specially chosen to blend in naturally wherever installed. Not only the
More informationSAMSUNG CONTROL KIT. installation manual. imagine the possibilities EN ES FR IT PT DE DB A-04 MIM-E03 N
MIM-E03 N SAMSUNG CONTROL KIT installation manual imagine the possibilities Thank you for purchasing this Samsung product. EN ES FR IT PT DE DB68-05388A-04 Contents Safety precautions... 3 Product specifications...
More informationDraft COMMUNICATION FROM THE COMMISSION
EUROPEAN COMMISSION Brussels, XXX [ ](2012) XXX draft Draft COMMUNICATION FROM THE COMMISSION in the framework of the implementation of Commission Regulation (EU) No / implementing Directive 2009/125/EC
More informationInstaller manual AMS 10
Installer manual LE LEK LEK K 6 / 108 / 1012 / 1016 K LE Air/water heat pump UN IHB EN 17492 331942 Table of Contents 1 Important information System solution Safety information Serial number Recovery
More informationHEAT PUMPS SiOS SYSTEM TERMINAL UNITS UNICO CONDITIONER FIXED AIR PORTABLE AIR CONDITIONER AIR COOLER VMC DEHUMIDIFIERS HUMIDIFIERS
106 PERSONAL COMFORT GAS STOVES FAN HEATERS CERAMIC FAN HEATERS DEHUMIDIFIERS HUMIDIFIERS AIR COOLER PELLET STOVES PORTABLE AIR FIXED AIR SYSTEM TERMINAL UNITS HEAT PUMPS SiOS VMC 107 THE RANGE The air
More informationANNEXES. to the. COMMISSION REGULATION (EU) No /..
EUROPEAN COMMISSION Brussels, 30.11.2016 C(2016) 7769 final ANNEXES 1 to 5 ANNEXES to the COMMISSION REGULATION (EU) No /.. implementing Directive 2009/125/EC of the European Parliament and of the Council
More informationMADE IN ITALY BY OLIMPIA SPLENDID
MADE IN ITALY BY OLIMPIA SPLENDID THE AIR CONDITIONER WITHOUT OUTDOOR UNIT SINCE 1998 THE DESIRE TO INNOVATE AND STAND OUT WITH UNIQUE PRODUCTS WHICH OFFER TECHNOLOGICAL SOLUTIONS, BEAUTY AND RESPECT
More informationCOMMISSION REGULATION (EU) No /.. of XXX
EUROPEAN COMMISSION Brussels, XXX [ ](2014) XXX draft COMMISSION REGULATION (EU) No /.. of XXX implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign
More information4. VRF - Digital Variable Multi (DVM) 226. Introduction Residential - Room Air Conditioner (RAC) Multi Split - Free Joint Multi (FJM) 56
Introduction 4 Samsung Climate Solutions Samsung Innovation Reference Sites Product Categories Product Range 1. Residential - Room Air Conditioner (RAC) 14 New for 2018 Line-up Technology Wind-Free Ultra
More informationACCESSIBLE COMFORT RESIDENTIAL
ACCESSIBLE COMFORT RESIDENTIAL ACCESSIBLE COMFORT MY NEW DESIGN OBJECT, DIRECT FROM THE FUTURE Every day excellence The new Mirai was created and developed with the aim of achieving total osmosis between
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G07LLCC AS G09LLCC AS G12LLCC OUTDOOR AO G07LLCC AO G09LLCC AO G12LLCC 1.INDOOR UNIT : AS G07LLCC AS G09LLCC AS G12LLCC DTR_AS087E_02
More informationRESIDENTIAL MONO&MULTI 2015
RESIDENTIAL MONO&MULTI 2015 RESIDENTIAL&COMMERCIAL CATALOGUE www.hokkaido.it 2015 RESIDENTIAL & COMMERCIAL CATALOGUE 2015 Hokkaido is a brand of Termal Group, a company based in Italy and having an international
More informationmakes technology hokkaido
2018 GENERAL CATALOGUE Hokkaido, a leading company in the air conditioning market in Italy and Europe since 2008, stands apart as a company able to meet all supply needs, satisfying even the most demanding
More informationSTYLISH SIMPLICITY. R32&R410A refrigerant Hybrid.
2018 STYLISH SIMPLICITY R32&R410A refrigerant Hybrid www.mitsubishi-termal.it MHI Italian design, Japanese technology Hybrid Paolo Ramazzotti Engineer and Product Designer TENSA INDUSTRIAL DESIGN, Milano
More informationSupporting your happiness and the happiness of those who are precious to you.
GENERAL CATALOGUE 2016 Supporting your happiness and the happiness of those who are precious to you. Mitsubishi Heavy Industries has always been committed to improve the quality of life through technological
More information(Non-legislative acts) REGULATIONS
20.12.2016 L 346/1 II (Non-legislative acts) REGULATIONS COMMISSION REGULATION (EU) 2016/2281 of 30 November 2016 implementing Directive 2009/125/EC of the European Parliament and of the Council establishing
More informationWrap Yourself in Comfort and Quiet Eco-conscious Technologies from Japan
Wrap Yourself in Comfort and Quiet Eco-conscious Technologies from Japan Product Line ne Catalogue 2015 2 SERIES 3 MSH-GF SERIES MSH-GF25/35VA MSH-GF50/60/80VA The unique product series: The perfect combination
More informationENTE CERTIFICAZIONE MACCHINE
ENTE CERTIFICAZIONE MACCHINE Organismo di Certificazione e di Ispezione - unto GS Ente di Formazione n. 6737 - Laboratorio di rova ISO/IEC 17025 Test Report EN 14825:2013 COMMISSION REGULATION (EU) No
More informationAir Cooled Chillers & Heat Pumps WinPACK HE-A
Air Cooled Chillers & Heat Pumps WinPACK HE-A TCAEY-THAEY 2110-4340 1 Air Cooled Chillers & Heat Pumps WinPACK HE-A TCAEY-THAEY 2110-4340 Cooling capacity: 91,6-345 kw Heating capacity: 110,5-357 kw Class
More informationInstaller manual NIBE F135
Installer manual Exhaust air module IHB GB 1622-4 331432 Table of Contents 1 Important information 4 Index 34 Safety information 4 2 Delivery and handling 7 Transport 7 Assembly 7 Supplied components
More informationAIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw
COMFORT HEAT PUMPS AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw climaveneta.com COMFORT HEAT PUMPS PERFECT COMFORT AND MAXIMUM EFFICIENCY Air to water heat pump for outdoor installation,
More informationWP2 European Product Analysis, Task 2.1 Determining energy efficiency criteria, D 2.1 Periodic Criteria Papers (first set)
Topten ACT Criteria Paper Air conditioners 14.Juli 2015 Anette Michel Bush Energie GmbH anette.michel@topten.eu Topten ACT aims at transforming the European market of energy-using products towards higher
More informationPRODIGY 3D Inverter. Technical Manual
PRODIGY 3D Inverter Technical Manual CONTENTS 1. Precaution... 3 1.1 Safety Precaution... 3 1.2 Warning... 3 2. Function and specifications... 5 3. Dimension... 10 3.1 Indoor Unit... 10 3.2 Outdoor Unit...
More informationJust feel well. 2017/2018 Air conditioning
1947-20 17 2017/2018 Air conditioning Unique solutions 40 Unique and advanced design for vertical or horizontal installation VERTICAL INSTALLATION q Vertical installation with compact dimensions, only
More information2017/2018 Air conditioning
1947 20 17 Just feel well 2017/2018 Air conditioning Multisplit DCI Cooling & heating YCZ RESIDENTIAL MULTISPLIT DUO/TRIO/QUATTRO/CINCO YCZ218 YCZ327 YCZ430 YCZ542 UPGRADE + PRODUCTS Efficient. Competitive.
More informationPRODUCT LINE-UP Residential & Light Commercial air conditioners
PRODUCT LINE-UP Residential & Light Commercial air conditioners Carrier air conditioning Energy savings Maximum energy savings thanks to accurate digital power control and super-efficient compressor. Comfort
More informationTechnical data LA 60TUR+
Technical data LA 6TUR+ Device information LA 6TUR+ Design - Heat source Outside air - Model Universal design reversible - Regulation - Thermal energy metering Integrated - Installation location Outdoors
More informationTribology Characteristics of HFO and HC Refrigerants with Immiscible Oils - Effect of Refrigerant with Unsaturated Bond -
Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 21 Tribology Characteristics of HFO and HC Refrigerants with Immiscible Oils - Effect of
More informationRoom air conditioners: Recommendations for policy design May 2011
Room air conditioners: Recommendations for policy design May 2011 1. Summary Split variable speed (inverter) air conditioners are today s best available technology (BAT). The most efficient models on the
More informationyears Just feel well 2017/2018 Air conditioning
1947-2017 years Just feel well 2017/2018 Air conditioning 2 Just feel well Contact Us An international sales network www.airwell-residential.com Contact details [ HEADQUARTERS ] 3, avenue du Centre - Les
More informationUnits without Remote Controller Units without Remote Controller Panel Units with Wireless Remote Controller
47 SERIES SELECTION Series line-up consists of two types of indoor units. Choose the model that best matches room conditions. STEP 1 SELECT INDOOR UNIT Select the optimal unit and capacity required to
More information30RBV/30RQV Inverter Air-Cooled Liquid chillers & Reversible Air to Water Heat Pumps PRODUCT SELECTION DATA INSTALLATION, OPERATION AND
PRODUCT SELECTION DATA INSTALLATION, OPERATION AND Easy and fast installation MAINTENANCE INSTRUCTIONS Hydronic module available Inverter technology compressor and fans Superior reliability Inverter Air-Cooled
More informationInformation on the Platform HEIZUNGSlabel. Contents
Status 22.07.2015 Information on the Platform HEIZUNGSlabel Contents 1. GLOSSARY HEIZUNGSlabel...2 2. FAQs...9 3. Examples of Illustrations...12 3.1. Controls with supplementary sensors...12 3.2. Storage
More information2016/2017. Air conditioning
2016/2017 Air conditioning 2 Contact Us An international sales network www.airwell-residential.com Contact details [ HEADQUARTERS ] 3, avenue du Centre - Les Quadrants - Bâtiment A 78280 Guyancourt - FRANCE
More informationHEAT PUMP Heat pump air conditioner. Thanks to this feature you can replace traditional heating in intermediate seasons or support it.
UNIO inverter The first air-conditioner without outdoor unit with inverter technology. UNIO INVERTER 9 SF od. 01068 UNIO INVERTER 9 HP od. 01060 UNIO INVERTER 12 SF od. 01067 UNIO INVERTER 12 HP od. 01052
More informationAIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw
COMFORT CHILLERS AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw climaveneta.com COMFORT CHILLERS PERFECT COMFORT AND MAXIMUM EFFICIENCY Air-cooled liquid chiller for outside installation
More informationA2A, A2W & DHW HEAT PUMP & AIR COND
A2A, A2W & DHW HEAT PUMP & AIR COND iseries TM OUTDOOR UNITS STANDARD OPERATION LIMIT OPERATION LIMIT -32 C -15 C +43 C +50 C By using state-of-the-art DC Inverter technology, iseries modulates the power
More informationDaikin Sensira. Refreshingly new. Discreet wall mounted unit providing high efficiency and comfort
Daikin Sensira Refreshingly new Discreet wall mounted unit providing high efficiency and comfort Why choose Daikin 2 Creating the perfect indoor climate is what Daikin units are all about. With more than
More informationTechnical data LA 9S-TU
Technical data LA 9S-TU Device information LA 9S-TU Design - Heat source Outside air - Model Universal design - Regulation - Thermal energy metering Integrated - Installation location Outdoors - Performance
More information2015 Air conditioning
2015 Air conditioning 2 Contact Us An international sales network www.airwell-residential.com Contact details [ HEADQUARTERS ] 3, avenue du Centre Les Quadrants - Bât. A 78280 Guyancourt - FRANCE [ LITERATURE
More informationEXHAUST AIR HEAT PUMPS EVALUATED FOR NORDIC CIRCUMSTANCES
Poster P.6.13-1 - EXHAUST AIR HEAT PUMPS EVALUATED FOR NORDIC CIRCUMSTANCES Markus Lindahl, MSc, SP Technical Research Institute of Technology, Energy Technology, Box 857, 501 15 Borås, Sweden; Caroline,
More informationCOMMISSION REGULATION (EU) No /.. of XXX
EUROPEAN COMMISSION Brussels, XXX [ ](2013) XXX draft COMMISSION REGULATION (EU) No /.. of XXX implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign
More informationEHPA Testing Regulation
EHPA Testing Regulation Testing of Heat Pumps for Domestic Hot Water Production Terms, Test Conditions and Test Method based on EN 16147 Additional requirements for granting the international quality label
More informationAIR COOLED ROOFTOP UNITS, COOLING CAPACITY FROM 50 TO 240 kw, AIRFLOW FROM TO m3/h
COMFORT ROOFTOP UNITS AIR COOLED ROOFTOP UNITS, COOLING CAPACITY FROM 50 TO 240 kw, AIRFLOW FROM 10000 TO 45000 m3/h climaveneta.com COMFORT ROOFTOP UNITS ENGINEERED FOR MAXIMUM EFFICIENCY AND VERSATILITY
More informationDaikin Sensira R-32. Refreshingly new. Discreet wall mounted unit providing high efficiency and comfort
Daikin Sensira R-32 Refreshingly new Discreet wall mounted unit providing high efficiency and comfort Why choose Daikin 2 Creating the perfect indoor climate is what Daikin units are all about. With more
More informationEurope s first light commercial cassette system using R-32 refrigerant. Our mission The lowest environmental impact
Europe s first light commercial cassette system using R-32 refrigerant Our mission The lowest environmental impact It s here The evolution of pure comfort and efficiency 2 Discover the next generation
More informationSHORAI. hatever you need. Do you want to improve your quality of life?
Do you want to improve your quality of life? SHORAI TOSHIBA AIR CONDITIONING RESIDENTIAL SOLUTIONS HIGH WALL INDOOR INVERTER UNIT SHORAI hatever you need SHORAI IMPROVE YOUR QUALITY OF LIFE EFFICIENCY
More informationREGULATION (EU) N. 2016/2281 FOR COMFORT CHILLERS
Climaveneta Technical Documentation REGULATION (EU) N. 2016/2281 FOR COMFORT CHILLERS Ecodesign requirements for cooling products AIR COOLED CHILLERS TECS2 HFO 0351-1053 Cooling Capacity Range 338-1014
More informationLocal air conditioner
Instruction Manual Local air conditioner LAC08C16 Contents Safety Warnings...4 Unpacking...7 Product Overview...8 Front View...8 Rear View...8 Control Panel...9 Remote Control... 10 Moving the Unit...10
More informationResidential Air Conditioners 2013 CATALOGUE / B
Residential Air Conditioners / B Welcome to the World of Air Conditioners Created by the largest Air Conditioner manufacturers globally Inventor units enjoy a sound reputation of exceptional quality and
More informationEco Compact Series GAS HEAT PUMP
Eco Compact Series GAS PUMP CREATING AIR-CONDITIONED COMFORT GREAT COMFORT, LOW SOUND LEVELS Natural gas provides excellent power and performance. That is why Yanmar gas heat pump [GHP] s are the ideal
More informationTechnical Data Sheet. Brine/Water Heat Pumps 8 12kW - single phase 230V. Heliotherm Basic Comfort. Basic Comfort Advantages
Technical Data Sheet Air Ground Water Brine Cooling PV-ready Modulation Brine/Water Heat Pumps 8 12kW - single phase 230V Heliotherm Basic Comfort A fully modulating Brine/Water heat pump with leading-edge
More informationEnergy Efficient Product Policy in the European Union
Efficient Product Policy in the European Union 29 June 2016 Portuguese Association of Engineers Portuguese Association of HVAC&R Industry Robert Nuij Head of Sector Efficient Products Directorate General
More informationANNEXES TO WORKING DOCUMENT ON POSSIBLE ECODESIGN AND ENERGY LABELLING REQUIREMENTS FOR SOLID FUEL BOILERS (< 500 KW)
ANNEXES TO WORKING DOCUMENT ON POSSIBLE ECODESIGN AND ENERGY LABELLING REQUIREMENTS FOR SOLID FUEL BOILERS (< 500 KW) Table of Contents Annex I Definitions applicable for the purposes of Annex II to IV...
More informationMODEL LA 6 MI LA 9 MI LA 12 MI LA 16 MI. Heat output (kw)/cop at A-15/W35 5.9/ / / /2.33
Inverter-driven air source heat pump systems Dimplex Air-Eau is an exciting new range of inverter-driven air source heat pumps designed to match output to varying heating demand. With achievable CoPs of
More informationCARRIER RESIDENTIAL AND LIGHT COMMERCIAL PRODUCTS
CARRIER RESIDENTIAL AND LIGHT COMMERCIAL PRODUCTS Available from... Issue 1 INDEX HOME COMFORT SOLUTIONS 10 SINGLE SPLIT SYSTEMS 12 Portable QPD 14 Inverter Hi-Wall Standard 42QHC/38QHC 16 SINGLE SPLIT
More informationTemplate for comments Date: Document: Eurovent Association Comments on
TABLE FOR COMMENTS Name of submitr: Francesco Scuderi Affiliad organization of the submitr (if any): Eurovent Association Contact email of submitr: francesco.scuderi@eurovent.eu 1 NA NA There is not any
More information30RB/RQ Air-Cooled Liquid Chillers/Air-to-Water Heat Pumps. product selection data
product selection data Easy and fast installation Hydronic module available Economical operation Superior reliability Air-Cooled Liquid Chillers/Air-to-Water Heat Pumps 30RB/RQ 017-040 CARRIER participates
More informationTEST REPORT #4. Travis Crawford Dutch Uselton. Lennox Industries Inc Metrocrest Drive Carrollton, TX 75006
Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Low-GWP Alternative Refrigerants Evaluation Program (Low-GWP AREP) TEST REPORT #4 System Drop-in Test of Refrigerant R-32 in Split System Heat
More informationEWAT-B. Multi scroll chiller with R-32 refrigerant. First air cooled chiller with environmental friendly R-32 refrigerant
EWAT-B Multi scroll chiller with R-32 refrigerant First air cooled chiller with environmental friendly R-32 refrigerant Daikin, world s first company introducing a new generation of air cooled scroll chiller
More informationSubmitted to: For Reference Approval Construction
SUBITTAL DATA: SEZ-KD9A & SUZ-KA9A............... 9, BTU/H HORIZOTAL-DUCTED HEAT-PUP SYSTES Job ame: Location: Date: Purchaser: Engineer: Submitted to: For Reference Approval Construction System Designation:
More informationTechnical data LA 60TU
Technical data LA 6TU Device information LA 6TU Design - Heat source Outside air - Model Universal design - Regulation - Thermal energy metering Integrated - Installation location Outdoors - Performance
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG18KLCA ASYG24KLCA OUTDOOR AOYG18KLTA AOYG24KLTA DR_AS069EF_01 2018.03.16 Notices: Product specifications and design are subject to
More informationTechnical manual NIBE AG-AA10 Single split air to air heat pump
Technical manual NIBE AG-AA10 Single split air to air heat pump TABLE OF CONTENTS 1 SCOPE... 4 2 DIMENSIONAL DATA AND EXTERIOR APPEARANCE... 5 3 TECHNICAL SPECIFICATIONS... 7 4 REFRIGERANT CIRCUIT... 10
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G07LMCA AS G09LMCA AS G12LMCA AS G14LMCA OUTDOOR AO G07LMCA AO G09LMCA AO G12LMCA AO G14LMCA 1. INDOOR UNIT : AS G07LMCA AS G09LMCA
More informationMulti Inverter Air Conditioning Condensing Units - Summary
Multi Inverter Air Conditioning Condensing Units - Summary Model Description Nominal Max of Cooling Inverter No. Heating of (kw) Fan Condensing (kw) Coils Unit ECO18MS2 Twin Multi Inverter 5kW 5.2 6.1
More information