CONTENT. I. Product Description.2. II. Application Areas of Pain Spraying/Baking Booth.2. III. Equipment Constituents..2. V. Operating Principle.

Size: px
Start display at page:

Download "CONTENT. I. Product Description.2. II. Application Areas of Pain Spraying/Baking Booth.2. III. Equipment Constituents..2. V. Operating Principle."

Transcription

1

2 CONTENT I. Product Description.2 II. Application Areas of Pain Spraying/Baking Booth.2 III. Equipment Constituents..2 IV. Precautions for Use of Paint Spraying/Baking Booth..2 V. Operating Principle.3 VI. Technical Parameters of Baking Booth...5 VII. Functional Descriptions about Switches and Instruments of Microcomputer Control Box 6 VIII. Wiring Connection Diagram of Paint Spraying/Baking Booth..8 IX. Circuit Diagram...9 X. Common Failures and Maintenance...9 1

3 I. Product Description: Automobile paint spraying/baking booth is used for air purification during auto paint coating operation and drying operation after painting spray. Paint spraying and drying are performed in the same booth. This paint spraying/baking booth is typical of paint spraying and baking functions, provided with automatic thermostat paint spraying, ventilation, air purification, paint mist treatment, and winter hot-air supply functions during paint spraying, and automatic heating, thermostat timing, and timed shutdown function during paint baking. The equipment is reliable in running, simple for operation, and easy for maintenance. II. Application Areas for Paint Spraying/Baking Booth: Industrial Paint Coating III. Equipment Constituents: The equipment of this paint spraying/baking booth is composed of booth structure system, illumination System, air supply system, circulation system, air purification system, paint mist treatment system, pressure control devices, and electrical control system, etc. IV. Precautions for Use of Paint Spraying/Baking Booth: 1. Check for the normality of air pressure for paint spraying and coating, and ensure that the filtration system is clean, before spraying and coating start. 2. Check the air compressor and the oil/water/fine dust separator, and keep clean the paint spraying hose. 3. Spray gun, paint spraying hose, and mixing paint can be stored in clean places. 4. Except for use of air blow gun and dust sticking cloth for dedusting, all the other working procedures before painting spray shall be completed outside the paint baking 2

4 D A N G E R H az a rd o u s V oltag e. s ta y c le a r o f th e a rea follow lockout procedurres before s e rv ic in g eq uipm ent G u a n g D o n g Jing Zhong Jing In d u s tria l P a in tin g Eq u ip m e n t Co.L td. S ize mm B ao Zh on g B ao Auto Paint S p ra y in g /B a k in g B o o th Model BZB-S er ie s No Po w er kw V oltage Da te A dd : N o Lia ngs ha H ighway, Baiyun District, G ua ngz hou, G uan gdo ng,c hina H ttp: //w w w.gz-btb.com T el: booth. 5. Only paint spraying and baking working procedures can be performed in the paint baking booth, and the door of the baking booth can only be opened when vehicles are moving in and out. The air circulation system must be started during spraying and coating when the door is opened, to generate positive pressure and to ensure that the dust outside the house cannot enter into the room. 6. Wear the designated paint spraying protective site clothing and safety appliances to enter the paint baking booth for operation. 7. The inflammable articles inside the baking booth must be taken out during the baking operation. 8. It is not allowed for unnecessary personnel to enter the pain baking booth. V. Operating Principle: Inside CE Operation position indication JZJ JZJ21 Auto paint spraying/baking booth is composed of the paint baking room, hot-air generator, microcomputer program sensor electrical control cabinet, illumination System, During paint spraying, two set of main blower fan (1) and the two sets of blowers in the air chamber of top light boxes (3) suck the fresh air from the air inlet. At this point the upper air door will open automatically and vertically and the internal circulating air door (9) will close automatically, to initially pass through the first 3

5 course of dust filter screen (2) and to filtrate off the dusts in large particle size in the air. Then the air enters into the air chamber on the top of the paint baking booth and flows through the top filter cotton fiber and exhaust cabinet (optional) be discharged out of the spray booth, meanwhile the air pressure inside is always higher than outside so the dust is prevented validly from outside getting in. During paint baking, by making use of the burner with micro electromagnetic automatic control for ignition and heating, the cold airflow sucked in by 2 set of main blower fan (1) passes the heat exchanger for heat exchange to heat up the air. At this point the upper air door will close automatically in a horizontal way and the air door for internal circulation (9) will automatically open, to form an internal circulating status of hot blast air. The heated airflow inside the house structure will once again be sucked in through circulating air door, to pass the heat exchanger for heat exchange. The 4

6 temperature is incessantly and rapidly raised through such circulations and reciprocations. The blower fan and the heater will start up automatically, for the temperature inside the paint baking booth to keep constant and to hold the set temperature until the set operating time is finished to complete the operation VI. Technical Parameters for Paint Baking Booth: 1. Outside dimensions of paint spraying booth (L x W x H) mm: Inside dimensions of paint spraying and baking booth (L x W x H) mm: Large Door Size (W x H)mm: Capacity of Blower m 3 /h/unit 2 unit 5. Inside air speed:m/s:0.35 5

7 6. Air exchange volumn 次 /h: Top temperature Heating time(20 80 )/min: Lighting volume: Noisy: 80dB 11. TSP: mg/m3: Fuel consumption:4-6 kg/vehicle 13. Power:10.5kW VII. Manual of electric control switch and instrument: 1.Spray-paint switch Equipped with 2 buttons one pressed will keep normal temperature the other keep constant temperature. When the normal temperature button is on 2 wind generators are working and the burner is ignited when the spraying paint the constant temperature button should be adjust to on state 2.Lighting switch Equipped with 2 lighting switches one is on the left the other is on the right When need light turn on the 2 switches 3.Bake-paint switch After setting well the temperature and baking time Please press the normal temperature button to ignite the burner 1.5 to 3 minutes later the exhaust fan will stop automatically 4.Timer Timer is used to set the bake-paint time when the planned time is over the system will power off automatically. Operate method: turn the switch between M and s then turn the dial at the time u 6

8 need For example if you turn the dial on 4538 means the bake-paint time planned is 45 minutes and 38 seconds 5.Temperature controller For temperature control when the temperature reaches planned temperature the system will power off automatically. Operate method: turn the dial to set the temperature for example if you set the it 060 means the set time is 60 degree when the temperature reach 60 degree the system will power off automatically when the temperature is lower constant temperature the burner will be ignited automatically to heating Notice : please check the temperature set precise or not and insure the temperature set at or below 80 degree 6.Time accumulator: for record how long time of using the spray booth 7.Electric power indicator lamp When the electric control case is connect with electric power the lamp will on 8.Ignite indicator lamp When the burner is ignited the lamp will on 9.Fault indicator lamp When failed to ignite the lamp will on After turning on the ignite switch seconds the burner will be ignited and the electric valve will be open and the fuel fog sprayed from the fuel spigot will be ignited will spray 5 seconds later the flame will reach limitation and begin to burn if after 5 seconds still not ignited successfully the system will power off automatically meanwhile the fault indicator lamp will on If need re-ignite please await 30 seconds then press the red reset button 7

9 Notice: During the process of normal combustion of the burner, don t fill oil into the oil tank, as massive steam bubbles will be generated in the oiling process, and these steam bubbles will be sucked into the oil pump through oil pipe, which will give rise to burning-out due to sudden stop of fuel supply. On this account, the burner shall be refueled when it is not burning. Notice: The fuel used by the burner is diesel oil and it is prohibited to use gasoline and other oils. VIII. Connection Diagram for Paint Spraying/Baking Booth A A B U12 V12 W12 U22 V22 W22 U32 V32 W32 L N U42 N N N 18 N 19 B 抽风机 进风机 进风机 燃烧机 执行器 左照明 右照明 C C Rev. Approved Date Rev. DRAWN CHECKED D DESIGNED APPROVED SCALE TITLE D DRAWING NO IX. Circuit Diagram: ISSUDE DATE 8

10 4U4U V50HZQL QF1 3*10mm2L13P63A L234P60AL60(A)NPE10mm210mm2V1 V2 3*2.5mm23*2.5mm23*2.5mm23*1.5mm22*1.5mm2A 进风机 A B KM1 U1 FR1 W1 U12 V12 W12 KM2 U2 FR2 W2 U22 V22 W22 KM3 U3 V3 W3 FR3 U32 V32 W32 QF2 1P20A 2KM4 N U4 18 SA4 N 19 U4 SA5 N B C M1 抽风机 YDFW5.0A 5.5KW900R/MIN M2 进风机 YDFW4.5L 4KW900R/MIN M3 YDFW4.5L 4KW900R/MIN 燃烧器 RG5S 0.15KW 左照明 0.5KW 右照明 0.5KW C Rev. Approved Date Rev. DRAWN CHECKED D DESIGNED APPROVED SCALE TITLE D DRAWING NO. ISSUDE DATE X. Common Failures and Maintenance of Paint Baking Booth Failure Possible Cause Maintenance Method The indicator lamp for failure of burner turns on after the burner has been started for 15 seconds. 4. Dismantle the electrical control box to towel off 1. No more oil in oil tank 2. Air leak at the joint of oil pipe 3. Too dirty filter screen on oil inlet4. Too dirty magic eye Too small openness of air door at the air suction inlet of 1. Fill up the oil tank with oil. 2. Re-connect the oil pipe properly. 3. Clean the filter screen. 4. Dismantle the electrical control box to towel off the magic eye. To widen the air door until no black fume emits. 9

11 the magic eye. the burner The motor of burner fails to rotate. The air inlet is fairly small during paint spraying. Heating is slow during paint baking. The main blower fan fails to start The set time for time meter is up. 2. The temperature shown on the thermometer has reached the set temperature. 3. The oil pump is blocked 1. The 1 st course of filter cotton fiber is blocked. 2. The air valve is in the open status 1. The air valve is not opened. 1. The fuse is blown out. 2. The thermal relay is displaced. 3. The motor is in short circuit. 1. Re-set the time Re-set the temperature. 2. Check whether or not the rotating shaft of oil pump is blocked with any contaminant or oil dreg. 1. Clean the 1 st course of filter cotton fiber. 2. Check for the action of air valve. 1. Check for the action of the air valve. 1. Replace the fuse. 2. Press the reset button. 3. Replace the motor. 10

INSTALLATION CHART Guangli Spray booth Model: GL1

INSTALLATION CHART Guangli Spray booth Model: GL1 INSTALLATION CHART Guangli Spray booth Model: GL1 GZ GUANGLI EFE CO., LTD. Http://www.gzguangli.com E-mail:jimmy@gzguangli.com.cn Catalog Cover 1 Catalog 2 Description instruction 3 4-8 2 Description 1.

More information

FLAME115 INFRARED HEATER SERVICE MANUAL INDEX FIRE 115 WARNING

FLAME115 INFRARED HEATER SERVICE MANUAL INDEX FIRE 115 WARNING FLAME115 INFRARED HEATER SERVICE MANUAL INDEX 1. CONTROLS AND COMPONENTS 2. FLAME CONTROL CYCLES 3. MAINTENANCE SCHEDULE 4. TROUBLESHOOTING GUIDE 5. REPAIR PROCEDURES 1. FAN MOTOR ASSEMBLY 2. FUEL FILTER

More information

USER'S MANUAL PGE Single Package Rooftop

USER'S MANUAL PGE Single Package Rooftop USER'S MANUAL PGE Single Package Rooftop Gas Heating/Electric Cooling Units Sizes 036-150 3 to 12-1/2 Tons NOTE TO INSTALLER: This manual should be left with the equipment owner. WARNING: If the information

More information

DF400/DF600. Construction Heaters. Installation and Maintenance Manual

DF400/DF600. Construction Heaters. Installation and Maintenance Manual 342 N. Co. Rd. 400 East Valparaiso, IN 46383 219-464-8818 Fax 219-462-7985 www.heatwagon.com Installation and Maintenance Manual Please retain this manual for future reference. DF400/DF600 Construction

More information

Tel: Fax: Website:

Tel: Fax: Website: Vacuum Dehydration Oil Purification System(Oil Purifier) The water and particles contamination in lubrication, hydraulic and dielectric oils badly affect the oils performance and threaten system reliability.

More information

user s information manual

user s information manual user s information manual SINGLE PACKAGE ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS 580F Sizes 036-150 3 to 12 1 / 2 Tons Cancels: New OM11-18 10/15/00 NOTE TO INSTALLER This manual should be left with

More information

1. GENERAL SAFETY RULES

1. GENERAL SAFETY RULES ID180 & ID290 Indirect-Fired Diesel/Oil Construction Heaters Sure Flame Products Lethbridge, Alberta, Canada Telephone: (403)328-5353 Fax: (403)328-9956 www.sureflame.ca July 12, 2006 Service and Maintenance

More information

TM NOVEMBER 1986 HEATER, SPACE, MULTIFUEL WITH BLOWER, 60,000 BTU/HR, 120 V UH-68G ( )

TM NOVEMBER 1986 HEATER, SPACE, MULTIFUEL WITH BLOWER, 60,000 BTU/HR, 120 V UH-68G ( ) OPERATOR S, UNIT, AND INTERMEDIATE MAINTENANCE MANUAL TABLE OF CONTENTS i OPERATING INSTRUCTIONS 2-1 UNIT MAINTENANCE INSTRUCTIONS 3-1 INTERMEDIATE MAINTENANCE INSTRUCTIONS 4-1 MAINTENANCE ALLOCATION CHART

More information

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL USER S INFORMATION MANUAL FOR YOUR COMBINATION GAS HEATING/ELECTRIC COOLING AIR CONDITIONING UNIT DO NOT DESTROY. PLEASE READ CAREFULLY AND KEEP IN A SAFE PLACE FOR FUTURE REFERENCE BY A SERVICEMAN OR

More information

INTRODUCTION THIS MANUAL INCLUDES IMPORTANT SAFETY INFORMATION

INTRODUCTION THIS MANUAL INCLUDES IMPORTANT SAFETY INFORMATION INSTALLATION AND OPERATING INSTRUCTIONS FOR THE HARDY Fuel Oil Furnace Models D-140 & D-350 HARDY MANUFACTURING COMPANY, INC. 12345 ROAD 505 PHILADELPHIA, MS 39350 PHONE: (601) 656-5866 FAX: (601) 656-4559

More information

Italy Riello Brand, G20 Diesel Burner, Kcal/h, 10N Damp Motor. SUS304 Stainless Steel heat exchanger, argon arc welding;

Italy Riello Brand, G20 Diesel Burner, Kcal/h, 10N Damp Motor. SUS304 Stainless Steel heat exchanger, argon arc welding; Large-scale industrial used industry Painting production line, Shower examination line, Spray booth, Lift, Paint Mixing Room, Platnum Mainenance system, Prep Station booth, Prep Station Room, Prep Station

More information

ACORE Filtration Co.,Ltd provides engineering,

ACORE Filtration Co.,Ltd provides engineering, Oil Filtration Systems For Every Demanding Application VLF Lube Oil Purifier ACORE Filtration Co.,Ltd provides engineering, manufacturing, sales of industrial oil filtration systems, we have been striving

More information

OPERATING MANUAL. AIR CONDITIONER Duct Type. Indoor Unit ARTG36LH ARTG45LH ARTG54LH ARTG60LH PART NO KEEP THIS MANUAL FOR FUTURE REFERENCE

OPERATING MANUAL. AIR CONDITIONER Duct Type. Indoor Unit ARTG36LH ARTG45LH ARTG54LH ARTG60LH PART NO KEEP THIS MANUAL FOR FUTURE REFERENCE OPERATING MANUAL AIR CONDITIONER Duct Type Indoor Unit ARTG36LH ARTG45LH ARTG54LH ARTG60LH KEEP THIS MANUAL FOR FUTURE REFERENCE PART NO. 9374379583 CONTENTS SAFETY PRECAUTIONS... 2 FEATURES AND FUNCTIONS...

More information

A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents

A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents Boiler specifications A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents Burner General: Q. Burner and burner safeguards shall comply with the CGA

More information

Evaporation The process in which a liquid dissipates or emits vapor, fumes, or invisible minute particles.

Evaporation The process in which a liquid dissipates or emits vapor, fumes, or invisible minute particles. 35 Evaporation of waste wash water occurs during normal operation of the pressure, steam or automatic vehicle wash system. It is generally assumed that 10-30% of wash water is lost to evaporation. Accelerated

More information

OPERATING & MAINTENANCE MANUAL INDUSTRIAL DIRECT FIRED DIESEL/KEROSENE HEATERS IC 25

OPERATING & MAINTENANCE MANUAL INDUSTRIAL DIRECT FIRED DIESEL/KEROSENE HEATERS IC 25 OPERATING & MAINTENANCE MANUAL INDUSTRIAL DIRECT FIRED DIESEL/KEROSENE HEATERS IC 25 NOT FOR DOMESTIC USE SPACE HEATING ONLY Made By: Spitwater Australia Pty Ltd 953 Metry St North Albury, NSW, Australia

More information

Thermo 230 / 231 / 300 / 301 / Troubleshooting

Thermo 230 / 231 / 300 / 301 / Troubleshooting Thermo 230 / 231 / 300 / 301 / 350 5 Troubleshooting 5 Troubleshooting 5.1 General This section describes troubleshooting procedures for the heaters Thermo 230, 231, 300, 301 and 350. CAUTION Troubleshooting

More information

Heating, Air Conditioning, Ventilation. Отопление-Кондиционеры-Вентиляция. MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL

Heating, Air Conditioning, Ventilation. Отопление-Кондиционеры-Вентиляция. MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL Heating, Air Conditioning, Ventilation Отопление-Кондиционеры-Вентиляция MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL 1. Usage MTM 8-30 universal oil heater is designed for heating commercial rooms

More information

Inverter Swimming Pool Heat Pump

Inverter Swimming Pool Heat Pump P Inverter Swimming Pool Heat Pump Content I. Application... 2 II. Features... 2 III. Technical Parameter... 3 IV. Dimension... 4 V. Installation instruction... 5 VI. Operation instruction... 9 VII. Testing...

More information

Operation Manual. Airbrush Airbrush-Spray Booth Compressor Suction Unit Paint E420

Operation Manual. Airbrush Airbrush-Spray Booth Compressor Suction Unit Paint E420 Operation Manual Airbrush Airbrush-Spray Booth Compressor Suction Unit Paint E420 Read and follow the operating instructions and safety information before using for the first time. Technical changes reserved!

More information

HEAT & COOL MODEL (REVERSE CYCLE)

HEAT & COOL MODEL (REVERSE CYCLE) OPERATING MANUAL HEAT & COOL MODEL (REVERSE CYCLE) AIR CONDITIONER Duct Type Indoor Unit ARTG09LL ARTG12LL ARTG18LL KEEP THIS MANUAL FOR FUTURE REFERENCE P/N9374379439 CONTENTS SAFETY PRECAUTIONS... 1

More information

Fujitsu OPERATING MANUAL Air Conditioner DUCT TYPE

Fujitsu OPERATING MANUAL Air Conditioner DUCT TYPE Fujitsu OPERATING MANUAL Air Conditioner DUCT TYPE High Static High Static 3 Phase High Static Bulkhead Type Slimline Type ARTG30L ARTC36L ARTC30L ARTF18L ARTA24L ARTG36L ARTC45L ARTA30L ARTG45L ARTC54L

More information

FLOOR CONSOLE/ UNDER CEILING DUAL TYPE. ABT Series FUJITSU GENERAL LIMITED AIR CONDITIONER OPERATING MANUAL P/N

FLOOR CONSOLE/ UNDER CEILING DUAL TYPE. ABT Series FUJITSU GENERAL LIMITED AIR CONDITIONER OPERATING MANUAL P/N OPERATING MANUAL AIR CONDITIONER FLOOR CONSOLE/ UNDER CEILING DUAL TYPE ABT Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N9375756024 CONTENTS SAFETY PRECAUTIONS... 1 NAME OF PARTS...

More information

TQ Series. Electronic Control Pump Instruction Manual. 50Hz. ISO 9001 Certified Walrus Pump Co., Ltd.

TQ Series. Electronic Control Pump Instruction Manual. 50Hz. ISO 9001 Certified Walrus Pump Co., Ltd. TQ Series Electronic Control Pump Instruction Manual 50Hz ISO 9001 Certified Walrus Pump Co., Ltd. EC Declaration of Conformity Manufacturer: Walrus Pump Co., Ltd. Address: No. 83-14, Dapiantou, Sanjhih

More information

Installation & Maintenance Manual

Installation & Maintenance Manual Installation & Maintenance Manual MOL 200 S1L (B30A) Oil Burner 11/12 Tel: +44 (0) 1905 794331 Fax: +44 (0) 1905 794017 Email: info@nu-way.co.uk Web: www.nu-way.co.uk DESCRIPTION COMPONENTS 1. Shrouded

More information

SECTION AUXILIARY HEATER

SECTION AUXILIARY HEATER 14-301.03/ 1 2010MR12 SECTION 14-301.03 GENERAL DESCRIPTION The Thermo 300 auxiliary heating system is used in conjunction with the vehicle s heating system, in order to heat the passenger compartment

More information

Each heater has slightly different operational characteristics

Each heater has slightly different operational characteristics NOTE, YOU MAY WANT TO PRINT THIS GUIDE TO ASSIST YOU IN TROUBLE SHOOTING New information regarding the Ultra Low Sulfur Diesel Fuel Heater Trouble Shooting Guide Customer Name Phone Step 1. Basic Information

More information

OPERATING MANUAL AIR CONDITIONER DUCT TYPE. ART Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

OPERATING MANUAL AIR CONDITIONER DUCT TYPE. ART Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N OPERATING MANUAL AIR CONDITIONER DUCT TYPE ART Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N9374379293-02 CONTENTS SAFETY PRECAUTIONS... 1 NAME OF PARTS... 2 PREPARATORY OPERATION...

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

R410A. AIR CONDITIONER DUCT TYPE / ART Series OPERATING MANUAL. REFRIGERANT This Air Conditioner contains and operates with refrigerant R410A.

R410A. AIR CONDITIONER DUCT TYPE / ART Series OPERATING MANUAL. REFRIGERANT This Air Conditioner contains and operates with refrigerant R410A. AIR CONDITIONER DUCT TYPE / ART Series OPERATING MANUAL KEEP THIS OPERATION MANUAL FOR FUTURE REFERENCE R410A REFRIGERANT This Air Conditioner contains and operates with refrigerant R410A. THIS PRODUCT

More information

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL USER S INFORMATION MANUAL UPFLOW & DOWNFLOW/HORIZONTAL CONDENSING GAS FURNACES SAFETY Recognize this symbol as an indication of Important Safety Information If not installed, operated and maintained in

More information

RL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw

RL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw The RL/1 burners series covers a firing range from 107 to 398 kw, and it has been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil boilers. Optimisation

More information

UV Flame Supervision System

UV Flame Supervision System 7 783 UV Flame Supervision System DETACTOGYR LFE50 Series 02 ISO 9001 The LFE50 is a self-checking UV flame supervision system designed for use with continuously operating burners or for burners running

More information

FJH-3 5B1/(2) Fuel Fired Air Heater Manual of Installation Operation and Maintenance

FJH-3 5B1/(2) Fuel Fired Air Heater Manual of Installation Operation and Maintenance R FJH-3 5B1/(2) Fuel Fired Air Heater Manual of Installation Operation and Maintenance Contents I. Scope... 1 II. Technical Parameters... 1 III. Structure and Working Philosophy... 1 IV. Instruction on

More information

DH-Direct Fired Poultry Farm Diesel Heater

DH-Direct Fired Poultry Farm Diesel Heater DH-Direct Fired Poultry Farm Diesel Heater Comparison of Diesel Heater to Gas Heater Diesel LPG Gas LPG Gas KW 43 70 120 Fuel consumption/hr 3 5.1 8.8 Heat output 37000 60000 100000 Cost of fuel/lit or

More information

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature Service Literature Corp. 0804 L2 Revised 05 05 2008 G71MPP G71MPP SERIES UNITS G71MPP series units are high efficiency multi position (upflow, downflow, horizontal right and left) gas furnaces equipped

More information

USERS MANUAL FOR GAS BOILERS

USERS MANUAL FOR GAS BOILERS USERS MANUAL FOR GAS BOILERS PLEASE READ THE MANUAL CAREFULLY: IT CONTAINS IMPORTANT INFORMATION REGARDING SAFETY, INSTALLATION, USE AND MAINTENANCE OF THE APPLIANCE MODELS: NOVADENS 24 NOVADENS 24C NOVADENS

More information

Presentation On Industrial Boiler Operation And Maintenance

Presentation On Industrial Boiler Operation And Maintenance Presentation On Industrial Boiler Operation And Maintenance Supervised By: Engr. Poresh Kanti Das GM-MAL RIP, Mulgoan, Kaligonj, Gajipur Boiler fundamental. Assessment On Heat recovery Boiler. Boiler Operation.

More information

CAST IRON ATMOSPHERIC BOILERS

CAST IRON ATMOSPHERIC BOILERS CST IRON TMOSPHERIC OILERS 006 gas-fired, central heating only, electronic ignition High efficiency boilers designed heating large domestic application. Ideal for installation in any boiler room. Cast-iron

More information

en Direct oil-fired space heaters HD... Operator's manual

en Direct oil-fired space heaters HD... Operator's manual 0211670en 002 12.2007 Direct oil-fired space heaters HD... Operator's manual Table of contents 1. Foreword 5 2. Safety information 6 2.1 General recommendations... 6 2.2 Safety devices... 7 2.3 Labels...

More information

4-2 Climate control. Ventilator control. & Center and side ventilators

4-2 Climate control. Ventilator control. & Center and side ventilators Climate control Ventilator control... 4-2 Center and side ventilators... 4-2 Climate control panel... 4-3 Type A... 4-3 Type B... 4-4 Type C... 4-5 Type D... 4-6 Automatic climate control operation (type

More information

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-400 INDIRECT FIRED SPACE HEATERS

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-400 INDIRECT FIRED SPACE HEATERS OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For FVO-400 INDIRECT FIRED SPACE HEATERS CERTIFIED FOR USE IN CANADA AND U.S.A. As per CSA B140.8 Portable Oil Fired Heaters / CSA B140.02003

More information

C Note! LGI16... Burner Controls. Building Technologies

C Note! LGI16... Burner Controls. Building Technologies 7 786 Burner Controls LGI16... Burner controls For use on industrial furnaces For burners in continuous operation Without fan control and air pressure supervision Flame supervision - with QR53... / QR55,

More information

DIESEL SPACE HEATER, DIESEL TYPE 30KW CT2142. Instruction & Assembly SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

DIESEL SPACE HEATER, DIESEL TYPE 30KW CT2142. Instruction & Assembly SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE DIESEL SPACE HEATER, DIESEL TYPE 30KW CT2142 Instruction & Assembly SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE 1 EC DECLARATION OF CONFORMITY We CANNON TOOLS LTD 20 Station road, Rowley Regis, West Midlands,B65

More information

PVE SERIES POWER VENTER SYSTEM MANUAL

PVE SERIES POWER VENTER SYSTEM MANUAL PVE SERIES POWER VENTER SYSTEM MANUAL Contents Page I. Typical Venting System Components 2 II. System Operation 3 III. Power Venter Sizing 3,4 IV. Installation Safety Instructions 5,6 V. Installation of

More information

Flame relay units are necessary in most industrial combustion systems. These flame relay models are capable of meeting most application needs.

Flame relay units are necessary in most industrial combustion systems. These flame relay models are capable of meeting most application needs. Flame relay units are necessary in most industrial combustion systems. These flame relay models are capable of meeting most application needs. Hauck Part No. Voltage Mounting Base Flame Detectors Display

More information

MV Hydro 5. MV Hydro 5-S Diesel Powered Water Heater Instruction Manual Ed MV Heating UK Ltd

MV Hydro 5. MV Hydro 5-S Diesel Powered Water Heater Instruction Manual Ed MV Heating UK Ltd MV Hydro 5-S Diesel Powered Water Heater Instruction Manual Ed. 2.0 Unit 6 Second Avenue Business Park Millbrook Southampton SO5 0LP MV Hydro 5 2 Preface Thank you for purchasing the MV Hydro 5 Water heater.

More information

CODE MODEL TYPE PRESS 60 N 616 T PRESS 60 N 616 T80

CODE MODEL TYPE PRESS 60 N 616 T PRESS 60 N 616 T80 Installation, use and maintenance instructions Heavy oil burner CODE MODEL TYPE 3434985 PRESS 60 N 616 T80 3434986 PRESS 60 N 616 T80 291 (2) - 01/2009 Thermal power - Output Operation Fuel Electrical

More information

Dexter Commercial Vended Stack Washer Dryer. Dryer Troubleshooting, Fault Codes, And Schematics. Starting serial number (12/13)

Dexter Commercial Vended Stack Washer Dryer. Dryer Troubleshooting, Fault Codes, And Schematics. Starting serial number (12/13) Dexter Commercial Vended Stack Washer Dryer Dryer Troubleshooting, Fault Codes, And Schematics Starting serial number 481983 8533-070-001 (12/13) Dryer Trouble Shooting Electronic Control Diagnostic Lights

More information

TWO STAGE HEAVY OIL BURNERS

TWO STAGE HEAVY OIL BURNERS TWO STAGE HEAVY OIL BURNERS PRESS N SERIES PRESS 30 N 85/171 342 kw PRESS 45 N 114/205 513 kw PRESS 60 N 171/342 684 kw PRESS 100 N 285/490 1140 kw The PRESS N series of burners covers a firing range from

More information

Topic: Mechanical Ventilation Refresher Reference #: DG Level of Instruction: In service personnel Time Required: 3 hours

Topic: Mechanical Ventilation Refresher Reference #: DG Level of Instruction: In service personnel Time Required: 3 hours Topic: Mechanical Ventilation Refresher Reference #: DG 14-07 Level of Instruction: In service personnel Time Required: 3 hours Instructor Preparation: The purpose of this drill is to conduct refresher

More information

WINDOW TYPE COOLING MODEL AKT7F AKT9F REVERSE CYCLE MODEL AKT7U AKT9U FUJITSU GENERAL LIMITED

WINDOW TYPE COOLING MODEL AKT7F AKT9F REVERSE CYCLE MODEL AKT7U AKT9U FUJITSU GENERAL LIMITED OPERATING MANUAL OPERATING MANUAL BEDIENUNGSANLEITUNG MODE D EMPLOI MANUAL DE FUNCIONAMIENTO MANUALE DI ISTRUZIONI ΕΓΧΕΙΡΙ ΙΟ ΛΕΙΤΟΥΡΓΙΑΣ MANUAL DE INSTRUÇÕES ROOM AIR CONDITIONER WINDOW TYPE COOLING MODEL

More information

Field Start-Up Sheet Direct Fired Gas Equipment

Field Start-Up Sheet Direct Fired Gas Equipment Customer: Sales Representative: Model Number: Serial Number: Field Start-Up Sheet Direct Fired Gas Equipment ***Please Print*** INITIAL INSPECTION I. Installer Responsibilities 1. Remote Panel: All interconnecting

More information

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL CONTENTS SAFETY INFORMATION................ 2 FOR YOUR SAFETY...................... 2 SYSTEM OPERATION.................. 2 THERMOSTATS.......................... 2 INTERMITTENT IGNITION DEVICE..........

More information

CONTENTS SAFETY PRECAUTIONS. En-1 DANGER! CAUTION!

CONTENTS SAFETY PRECAUTIONS. En-1 DANGER! CAUTION! CONTENTS SAFETY PRECAUTIONS... 1 NAME OF PARTS... 2 PREPARATORY OPERATION... 3 OPERATION... 3 TIMER FUNCTIONS... 5 ON/OFF TIMER... 5 WEEKLY TIMER... 6 TEMPERATURE SET BACK TIMER... 8 FILTER DISPLAY RESET...

More information

AUTOMOTIVE AIR CONDITIONER REFRIGERANT HANDLING SYSTEM

AUTOMOTIVE AIR CONDITIONER REFRIGERANT HANDLING SYSTEM AUTOMOTIVE AIR CONDITIONER REFRIGERANT HANDLING SYSTEM OPERATION MANUAL Index I Caution.... 2 II Notation.. 2 III Technical parameter...3 IV Functions... 3 V Device Description. 3 (I) Control panel. 4

More information

1. The structure and its description

1. The structure and its description Thank you for using our KYUNG-DONG NAVIEN. To use this boiler in the proper way, be sure to read this manual fully before using it, and keep this manual with the warranty of the quality in a safe place.

More information

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS This electrical appliance must always be used according to the following safety instructions. Save these instructions as this manual contains important safety and operating

More information

FagronLab NP-1 UV. Negative pressure workbench. User Manual

FagronLab NP-1 UV. Negative pressure workbench. User Manual Negative pressure workbench User Manual Table of contents 1. Introduction... 3 2. Service... 3 3. Warranty... 3 4. Application range... 4 5. Main technical parameters... 4 6. Performance index... 5 Vibration

More information

Title: Fire Protection Effective Date: 7/1/2013 Control Number: THG_0039 Revision Number: 1 Date: 10/23/2015 Annual Review Completed: 5/13/2015

Title: Fire Protection Effective Date: 7/1/2013 Control Number: THG_0039 Revision Number: 1 Date: 10/23/2015 Annual Review Completed: 5/13/2015 Title: Fire Protection Effective Date: 7/1/2013 Control Number: THG_0039 Revision Number: 1 Date: 10/23/2015 Annual Review Completed: 5/13/2015 Fire Protection I. INTRODUCTION II. GENERAL GUIDELINES III.

More information

Operating instructions

Operating instructions Operating instructions (Translation of the original operating instructions) Type TEKA FILTERCUBE-MV TEKA Absaug- und Entsorgungstechnologie GmbH Industriestraße 13 D-46342 Velen Postfach 1137 D-46334 Velen

More information

DKO 974/976 DKO 974 N/976 N. Oil Burner Safety Control

DKO 974/976 DKO 974 N/976 N. Oil Burner Safety Control Oil Burner Safety Control A Honeywell Company DKO 974 N/976 N For 1- or 2-stage oil burners up to 30 kg/h throughput and intermittent operations with or without oil preheating Flame detection: - Photoresistor

More information

OPERATING MANUAL AIR CONDITIONER CASSETTE TYPE. AUT Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

OPERATING MANUAL AIR CONDITIONER CASSETTE TYPE. AUT Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N OPERATING MANUAL AIR CONDITIONER CASSETTE TYPE AUT Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N9378015029 CONTENTS SAFETY PRECAUTIONS... 1 NAME OF PARTS... 2 OPERATION... 2

More information

YUHUA PRE-HEATER ALWAYS THE RIGHT ANSWER

YUHUA PRE-HEATER ALWAYS THE RIGHT ANSWER PRE-HEATERS YUHUA PRE-HEATER ALWAYS THE RIGHT ANSWER Have to stay in the iced-up car to start and idle the engine to warm up the engine block and cab inside for over 15 minutes everyday in the cold winter?

More information

LGB Gas fired boiler

LGB Gas fired boiler LGB Gas fired boiler Control Supplement LGB-5 Series 2 Propane gas CSD-1 Control System Part Number 550-110-682/0304 Please read this page first Hazard definitions To the installer... The following terms

More information

PU-5 CONTROL PANEL - OPERATING MANUAL FOR PLANAR AIR HEATERS

PU-5 CONTROL PANEL - OPERATING MANUAL FOR PLANAR AIR HEATERS PU-5 CONTROL PANEL - OPERATING MANUAL FOR PLANAR AIR HEATERS PF Jones are official partners of Autoterm Europe Diesel Air Heaters and Engine Preheaters, offering as a service point and seller for Planar

More information

Auto Open Cap Heat Press Manual and Parts Book Model No.: KX-CAP-2X

Auto Open Cap Heat Press Manual and Parts Book Model No.: KX-CAP-2X Auto Open Cap Heat Press Manual and Parts Book Model No.: KX-CAP-2X CONTENTS I. Assembly Drawing ------------------------------------------------------------------------------2 II. Technical Parameters

More information

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS XPAK FT TYPE H - MODELS 088AR-398A SUGGESTED SPECIFICATIONS Catalog No.: 2100.91 Effective: 05/01/15 Replaces: new DIVISION 23 52 33.13 WALL-HUNG STAINLESS STEEL HEATING BOILERS PART 1 - GENERAL 1.1 SUMMARY

More information

BIX B-One 100 kw INSTALLATION GUIDE

BIX B-One 100 kw INSTALLATION GUIDE BIX B-One 100 kw INSTALLATION GUIDE Dear Customer, We thank you for choosing our product. The Bix B-One 100 Kw is a burner of advanced concept and technology, with a high reliability and construction quality.

More information

ML180UH SERIES GAS FURNACE WARNING WARNING

ML180UH SERIES GAS FURNACE WARNING WARNING 2017 Lennox Industries Inc. Dallas, Texas, USA 506525-01 04/2017 Supersedes 10/2015 ML180UH SERIES GAS FURNACE Improper installation, adjustment, alteration, service or maintenance can cause property damage,

More information

Fume Hood Safety TYPES OF FUME HOODS

Fume Hood Safety TYPES OF FUME HOODS Fume Hood Safety Fume hoods exhaust toxic, flammable, noxious, or hazardous fumes and vapors by capturing, diluting, and removing these materials. Fume hoods also provide physical protection against fire,

More information

WHU WATER HEATING UNITS. GENERAL MANUAL MODEL KEY. June 2007 WHU WATER HEATING UNITS

WHU WATER HEATING UNITS.  GENERAL MANUAL MODEL KEY. June 2007 WHU WATER HEATING UNITS WHU WATER HEATING UNITS GENERAL MANUAL MODEL KEY WHU Water Heating Unit Maximum heating power, kw Max. water inflow pressure, bar Voltage options GENERAL INFORMATION WHU water heater, producing hot water

More information

SELF-PRIMING JET PUMPS

SELF-PRIMING JET PUMPS SS Anti-Rust SS Shaft Copper & Cold-rolled SELF-PRIMING JET PUMPS CONTENTS 1. Applications.... Model Description.... Technical Data... 4. Implementation Standards... 5. Safety Precautions... 6. Product

More information

DAIKIN ROOM AIR CONDITIONER. Operation Manual

DAIKIN ROOM AIR CONDITIONER. Operation Manual DAIKIN ROOM AIR CONDITIONER Operation Manual FDXM25F2V1B FDXM50F2V1B FDXM35F2V1B FDXM60F2V1B CONTENTS READ BEFORE OPERATION Safety precautions... 2 Names of parts... 4 CARE Care and Cleaning... 6 TROUBLE

More information

Multi-Elec COMPACTE BOILER

Multi-Elec COMPACTE BOILER Multi-Elec COMPACTE BOILER TECHNICAL MANUAL 03/2013 CODE: 560956 CE Directive 2006/95/CEE British Standard EN 60335-1 (C 73800) FOR TECHNICAL HELP/ADVICE Call 0161 621 5960 or email info@atlanticboilers.com

More information

Operating Instructions

Operating Instructions Operating Instructions Typ TEKA CAREMASTER TEKA Absaug- und Entsorgungstechnologie GmbH Industriestraße 13 D-46342 Velen Postfach 1137 D-46334 Velen Tel.: +49 (0) 2863 9282-0 Fax: +49 (0) 2863 9282-72

More information

Are Your Kitchen Hood Filters Compliant?

Are Your Kitchen Hood Filters Compliant? Are Your Kitchen Hood Filters Compliant? Do your kitchen hood filters comply with the current Australian Standards for fire safety? Why Install Kitchen Exhaust Hood Filters? The purpose of a kitchen exhaust

More information

!!! Sample Written Program For Your Company. For BOILER SAFETY. Provided By:!!!

!!! Sample Written Program For Your Company. For BOILER SAFETY. Provided By:!!! Sample Written Program For Your Company For BOILER SAFETY Provided By: P.O. Box 2136 Slidell, LA 70458 Phone: 985-781-1444 Fax: 985-781-1446 Email: info@se-safety.com Purpose Boiler Safety Program The

More information

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL USER S INFORMATION MANUAL UPFLOW/HORIZONTAL & DOWNFLOW TWO STAGE INDUCED DRAFT GAS FURNACES Recognize this symbol as an indication of Important Safety Information If the information in this manual is not

More information

User s Information Manual

User s Information Manual 48AJ,AK,AW,AY020-060 Single-Package Rooftop Gas Heating Units with COMFORTLINK Controls and Scroll Compressors User s Information Manual NOTE TO INSTALLER This manual should be left with the equipment

More information

Light oil / kerosene burner

Light oil / kerosene burner Installation, use and maintenance instructions Light oil / kerosene burner One stage operation CODE MODEL TYPE 374445 G5 444T50 290238 (5) - 05/20 TECHNICAL DATA Thermal power output 28 60 kw 2.3 5 kg/h

More information

Oil Mist Separator Unit LGA 600 FUW

Oil Mist Separator Unit LGA 600 FUW MAHLE Industrialfiltration is now Filtration Group For more information, visit wwwfiltrationgroupcom Oil Mist Separator Unit LGA 600 FUW Nominal volume flow 600 m³/h 1 Features High performance oil mist

More information

THC 85N / 175N INDUSTRIAL / COMMERCIAL SPACE HEATER

THC 85N / 175N INDUSTRIAL / COMMERCIAL SPACE HEATER THC 85N / 175N INDUSTRIAL / COMMERCIAL SPACE HEATER Certified to / Certifié à CGA 2.14 M2000 Conforms to / Conforme à ANSI std Z83.7 2000 Suitable for indoor or outdoor installation / Unvented / Unattended

More information

BG2000S PRE-MIX GAS BURNER

BG2000S PRE-MIX GAS BURNER BG000S PRE-MIX GAS BURNER INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION STOKVIS ENERGY SYSTEMS 96R WALTON ROAD EAST MOLESEY SURREY KT8 0DL TEL: 08707 707 77 FAX: 08707 707 767 E-MAIL:info@stokvisboilers.com

More information

INSTALLATION INSTRUCTIONS # BURNER ASSEMBLY REPLACEMENT

INSTALLATION INSTRUCTIONS # BURNER ASSEMBLY REPLACEMENT INSTALLATION INSTRUCTIONS # 00-858726 BURNER ASSEMBLY REPLACEMENT C24GA BURNER ASSEMBLY REPLACEMENT Verify steamer has a K3 relay (1, Fig. 1) installed. If K3 relay is not in steamer, one must be installed

More information

Bench-Top Vacuum Oven with 28 segments programmable controller

Bench-Top Vacuum Oven with 28 segments programmable controller Bench-Top Vacuum Oven with 28 segments programmable controller DZF-6000F Series Vacuum Oven MTI Corporation www.mtixtl.com 1 Safety notes DZF Vacuum Oven Please read the following safety notes carefully

More information

Providing sustainable energy solutions worldwide. Installation- and maintenance instruction B 30 A

Providing sustainable energy solutions worldwide. Installation- and maintenance instruction B 30 A 178 038 51-2 2016-07-08 Providing sustainable energy solutions worldwide Installation- and maintenance instruction B 30 A DESCRIPTION Components 1. Shrouded disc 2. Nozzle 3. Ignition electrodes 4. Nozzle

More information

INSTALLATION AND MANINTENANCE INSTRUCTIONS

INSTALLATION AND MANINTENANCE INSTRUCTIONS INSTALLATION AND MANINTENANCE INSTRUCTIONS Appr. Nr. A 9503 T - 0085 AQ 0765 PEGASUS F2 T HIGH EFFICIENCY GAS-FIRED CAST-IRON BOILERS Models 51-68 - 85-102 2 Contents 1. General technical data 2. Dimensional

More information

Dexter Industrial On Premise Dryer. Troubleshooting, Fault Codes, And Schematics. Starting serial number Part # /13

Dexter Industrial On Premise Dryer. Troubleshooting, Fault Codes, And Schematics. Starting serial number Part # /13 Dexter Industrial On Premise Dryer Troubleshooting, Fault Codes, And Schematics Starting serial number Dryer Trouble Shooting Symptom Probable Cause Suggested Remedy Tumbler does not turn Drive belts Check

More information

Oil burners Brûleurs fioul Stookoliebranders

Oil burners Brûleurs fioul Stookoliebranders Installation, use and maintenance instructions Manuel d entretien Installatie-, gebruiks- en onderhoudsvoorschriften GB F NL Oil burners Brûleurs fioul Stookoliebranders One stage operation Fonctionnement

More information

Parts Available from

Parts Available from Montage und Bedienungsanleitung Manuel d entretien Installation, use and maintenance instructions Installatie-, gebruiks- en onderhoudsvoorschriften Oδηγίες εγκατάστασης, χρήσης και συντήρησης D F GB NL

More information

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL 2017 Lennox Industries Inc. Dallas, Texas, USA 506737-01 04/2017 Supersedes 03/2017 USER S INFORMATION MANUAL EL195UHE SERIES GAS FURNACE Improper installation, adjustment, alteration, service or maintenance

More information

TECHNICAL MANUAL OPERATOR'S, ORGANIZATIONAL, DIRECT AND GENERAL SUPPORT MAINTENANCE MANUAL

TECHNICAL MANUAL OPERATOR'S, ORGANIZATIONAL, DIRECT AND GENERAL SUPPORT MAINTENANCE MANUAL TECHNICAL MANUAL OPERATOR'S, ORGANIZATIONAL, DIRECT AND GENERAL SUPPORT MAINTENANCE MANUAL HEATER, SPACE, MULTI-FUEL, WITH BLOWER, 6,000 BTU/HR (HUNTER MODEL UH-68F) NSN 4520-01-050-5628 This copy is a

More information

Automatic Sublimation Transfer Machine Manual Model. No.: ASTM-40/48/64

Automatic Sublimation Transfer Machine Manual Model. No.: ASTM-40/48/64 Automatic Sublimation Transfer Machine Manual Model. No.: ASTM-40/48/64 MIC CONTENTS I. Assembly Drawing -----------------------------------------------------------------------------------2 II. Technical

More information

MICROTEC. Auto Open Heat Press Manual Model No.: SWH-2 CONTENTS

MICROTEC. Auto Open Heat Press Manual Model No.: SWH-2 CONTENTS Auto Open Heat Press Manual Model No.: SWH-2 CONTENTS I. Assembly Drawing -----------------------------------------------------------------------------------2 II. Technical Parameters -------------------------------------------------------------------------------2

More information

User's Infomation Manual

User's Infomation Manual User's Infomation Manual 574A GAS HEATING/ELECTRIC COOLING Cancels: OM01-69 OM10-28 02-07 NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Note to Installer:

More information

INSTRUCTIONS FOR USE OF COMBINED BOILER INTENDED FOR COMBUSTION OF BOTH PELLETS AND SOLID FUEL ABC COMBO

INSTRUCTIONS FOR USE OF COMBINED BOILER INTENDED FOR COMBUSTION OF BOTH PELLETS AND SOLID FUEL ABC COMBO INSTRUCTIONS FOR USE OF COMBINED BOILER INTENDED FOR COMBUSTION OF BOTH PELLETS AND SOLID FUEL ABC COMBO .Technical specifications Boiler power DESCRIPTION Water content in a boiler Required draft Supply

More information

POWDER GUIDE. Trouble shooting tips to maximise the benefits of Apcoshield Powder Coatings

POWDER GUIDE. Trouble shooting tips to maximise the benefits of Apcoshield Powder Coatings POWDER GUIDE From ASIAN PAINTS (I) LTD Trouble shooting tips to maximise the benefits of Apcoshield Powder Coatings Section A : Powder Application Problems Trouble Possible Causes Solutions 1. Poor charging

More information

ORT6WXA ORT9WXA Slide-out Rangehoods

ORT6WXA ORT9WXA Slide-out Rangehoods Instructions for the Use and Care and Installation of ORT6WXA ORT9WXA Slide-out Rangehoods CONTENT 1. GENERAL 2. SAFETY PRECAUTION 3.. WARNING!! 4.. INSTALLATION INSTRUCTIONS 5.. ATTENTION 6.OPERATION

More information

Dehumidifier User Manual. (For the series of DP40~DP70)

Dehumidifier User Manual. (For the series of DP40~DP70) Dehumidifier User Manual (For the series of DP40~DP70) Content I. Please read immediately... 1 II. Application... 2 III. Features... 2 IV. Technical Parameters... 3 V. Overall Dimension... 4 VI. Installation

More information