Models: A5HDC20AR A5HDC25AR. Horizontal Ducted Condensing Unit

Size: px
Start display at page:

Download "Models: A5HDC20AR A5HDC25AR. Horizontal Ducted Condensing Unit"

Transcription

1 Models: A5HDC20AR A5HDC25AR Horizontal Ducted Condensing Unit A5HDC-2009

2 A5HDC-2009 Table of Contents Table of Contents Nomenclature...2 Indoor Unit...2 Outdoor Unit...3 Product Line-Up...4 Features...6 Application Information...7 Operating Range...7 Refrigerant Circuit Diagram...8 Controller...9 Installation Guideline...11 Sound Data Sound Pressure Level NC Curve Engineering & Physical Data General Data Component Data Safety Devices Performance Data Calculation Steps Performance Table Outline and Dimension Electrical Data Wiring Diagram Service and Maintenance Troubleshooting Exploded View and Part List... 40

3 Nomenclature A5HDC-2009 Nomenclature Indoor A 5 CC 20 C R Brand A : Acson Refrigerant : Omitted if R22 4 : R407C 5 : R410A Model Name CC : Ceiling Concealed Capacity Index 20 : 20,000 Btu/h Chassis C : C series Model Type : Omitted if cooling only R : Heatpump 2

4 A5HDC-2009 Nomenclature Outdoor A 5 HDC 20 A R Brand A : Acson Refrigerant : Omitted if R22 4 : R407C 5 : R410A Model Name HDC : Horizontal Ducted Condensing Unit Capacity Index 20 : 20,000 Btu/h Chassis A : A series Model Type : Omitted if cooling only R : Heatpump 3

5 Nomenclature A5HDC-2009 Product Line-Up Indoor Unit A5CC-CR Classification A5CC-CR Heat Pump Nomenclature L2 PCB Handset SLM 3 Fin 20CR AFBA X X X X X X 25CR AFAA X X X X X X Bare Refrigerant Control Air Filter Air Purification CE Marking Others EPS Drain Pan 4

6 A5HDC-2009 Product Line-Up Outdoor Unit A5HDC-AR Classification Cap Tube Hydrophilic Coated Compressor Others A5HDC-AR Nomenclature Refrigerant Control Fin Safety Devices Marking Rotary CE Heat Pump 20AR AFBA X X X X 25AR AFAA X X X X 5

7 Features A5HDC-2009 Features Adequate External Static Pressure The external static pressure is specially designed to blend in most of the interior design and yet to ensure a sufficient heat transfer capability. Aluminium Slit Fin The unique slit fin on the heat exchanger greatly increases the heat transfer efficiency and thus boosts up the unit capacity. Short Piping Reduce installation cost, improved reliability efficiency compared to roof mounted units. Flexibility in Installation The supply and return grille can be selected based on end user or professional interior designer in integrating the HDC unit to their favorite interior design. Invisible & Evergreen To make your condensing unit invisible by installing it above the ceiling with only the supply and return grille exposed to view. This ceiling concealed ducted condensing type of design has made it an evergreen design without scarifying the previous floor space. 6

8 A5HDC-2009 Application Information Application Information Operating Range Ensure the operating temperature is in allowable range. Heatpump Cooling Heating Outdoor temp. ( CDB) STD Outdoor temp. ( CWB) 6 STD Indoor temp. ( CWB) Indoor temp. ( CDB) 27 Caution : The use of your air conditioner outside the range of working temperature and humidity can result in serious failure. Note: Standard Operating Range 7

9 Application Information A5HDC-2009 Refrigerant Circuit Diagram Model: A5CC20CR A5HDC20AR A5CC25CR A5HDC25AR

10 A5HDC-2009 Application Information Controller SLM SENSOR AUTO HIGH TEMP MED LOW TIMER COOL DRY FAN HEAT FAN SWING ON/OFF MODE SLEEP FAN ON/OFF TEMP SWING SLEEP TIMER MODE 7 Operation Guide 1. ON/OFF switch Press to start the air conditioner unit. Press again to stop the unit. 2. Temperature setting Set the desired room temperature. Press button to increase or decrease the set temperature. Setting range are between 16 C to 30 C (60 F to 80 F). 3. Operation Modes Press the mode button for select the type of operating mode. - Cooling Only : COOL, DRY, FAN - Heat Pump : AUTO, COOL, DRY, HEAT, FAN (AUTO mode is represented by both COOL and HEAT LED light on) 4. Fan Speed selection. Press the button until the desired fan speed is achieved. 5. Timer. Press the set button to select the switch timer of the air conditioner unit (the setting range is between 1 to 10 hours). 6. Sleep mode Press button to activate the sleep function can only be activated under cool or heating mode operation. Activated under cool mode operation, the set temperature will increase 0.5 C after 30minutes, 1 C after 1 hour and 2 C after 2hours. If it is actiaved under HEAT mode operation, the set temperature will be descreased 0.5 C after 30 minutes, 1 C after 1 hour and 2 C after 2 hours. 7. Air Swing Press button to activate the automatic air swing function. 8. Sensor Infra red sensor to receive signals from wireless controller. 9. LED Display To display the set temperature (in C) and timer delay setting (in hours). 10. Transmission source To transmit signals to the air conditioner. 9

11 Application Information A5HDC-2009 Installation Guideline Safety Precautions WARNING CAUTION Installation and maintenance should be performed by qualifi ed persons who are familiar with local code and regulation, and experienced with this type of appliance. All fi eld wiring must be installed in accordance with the national wiring regulation. Ensure that the rated voltage of the unit corresponds to that of the name plate before commencing wiring work according to the wiring diagram. The unit must be GROUNDED to prevent possible hazard due to insulation failure. All electrical wiring must not touch the refrigerant piping or any moving parts of the fan motors. Confi rm that the unit has been switched OFF before installing or servicing the unit. Disconnect from the main power supply before servicing the air conditioner unit. DO NOT pull out the power cord when the power is ON. This may cause serious electrical shocks which may result in fire hazards. Keep the indoor and outdoor units, power cable and transmission wiring, at least 1m from TVs and radios, to prevent distorted pictures and static. {Depending on the type and source of the electrical waves, static may be heard even when more than 1m away}. Please take note of the following important points when installing. Do not install the unit where leakage of flammable gas may occur. If gas leaks and accumulates around the unit, it may cause fire ignition. Ensure that drainage piping is connected properly. If the drainage piping is not connected properly, it may cause water leakage which will dampen the furniture. Do not overcharge the unit. This unit is factory pre-charged. Overcharge will cause over-current or damage to the compressor. Ensure that the unit s panel is closed after service or installation. Unsecured panels will cause the unit to operate noisily. Sharp edges and coil surfaces are potential locations which may cause injury hazards. Avoid from being in contact with these places. Before turning off the power supply, set the remote controller s ON/OFF switch to the OFF position to prevent the nuisance tripping of the unit. If this is not done, the unit s fans will start turning automatically when power resumes, posing a hazard to service personnel or the user. Do not operate any heating apparatus too close to the air conditioner unit. This may cause the plastic panel to melt or deform as a result of the excessive heat. Ensure the color of wires of the outdoor unit and the terminal markings are same to the indoors respectively. IMPORTANT : DO NOT INSTALL OR USE THE AIR CONDITIONER UNIT IN A LAUNDRY ROOM. Do not use joined and twisted wires for incoming power supply. NOTICE Disposal requirements Your air conditioning product is marked with this symbol. This means that electrical and electronic products shall not be mixed with unsorted household waste. Do not try to dismantle the system yourself: the dismantling of the air conditioning system, treatment of the refrigerant, of oil and of other parts must be done by a qualified installer in accordance with relevant local and national legislation. Air conditioners must be treated at a specialized treatment facility for re-use, recycling and recovery. By ensuring this product is disposed of correctly, you will help to prevent potential negative consequences for the environment and human health. Please contact the installer or local authority for more information. Batteries must be removed from the remote controller and disposed of separately in accordance with relevant local and national legislation. 10

12 A5HDC-2009 Application Information Caution Sharp edges and coil surfaces are potential injury hazard. Avoid from contact with them. Installation of Indoor Unit For installation of indoor unit, please refer to the indoor unit technical manual. Installation of Outdoor Unit The outdoor unit has to be installed as per recommended installation clearance (Diagram A) Make sure that the location is suitable for piping and drainage. Precaution steps as below : i) Use the hanging bracket supplied with the unit. ii) Ensure the support is strong enough to withstand the weight of the unit. iii) Incline the drain pipe as per diagram B. Do not install drain trap to the drain pipe, this is to prevent blockage of drain pipe during heat mode when defrost is in operation. iv) After completion of drain piping, confirm the drainage is good and there are no leaks. Diagram A Diagram B 11

13 Application Information A5HDC-2009 Wiring Wiring Electrical Connections Wiring regulations on wire diameters differ from country to country. Please refer to your LOCAL ELECTRICAL CODES for field wiring rules. Be sure that installation comply with such rules and regulations. General Precautions Ensure that the rated voltage of the unit corresponds to the name plate before carrying out proper wiring according to the wiring diagram. Provide a power outlet to be used exclusively for each unit. A power supply disconnect and a circuit breaker for over-current protection should be provided in the exclusive line. The unit must be GROUNDED to prevent possible hazards due to insulation failures. All wiring must be firmly connected. All wiring must not touch the hot refrigerant piping, compressor or any moving parts of fan motors. Refrigerant Piping Maximum Pipe Length And Maximum Number Of Bends When the pipe length becomes too long, both the capacity and reliability drop. As the number of bends increases, system piping resistance to the refrigerant flow increases, thus lowering the cooling capacity, and as the result the compressor may become defective. Always choose the shortest path and follow the recommendation as tabulated below: Data Model A5HDC20AR A5HDC25AR Max. Length, L 15 m 15 m Max. Elevation, H 8 m 8 m Max. No. of Bends Piping Sizes (Flare Connection Type) Piping sizes are as follows: Model A5HDC20AR A5HDC25AR Liquid (mm/in) 6.35 (1/4) 9.52 (3/8) Suction (mm/in) (5/8) (5/8) 12

14 A5HDC-2009 Application Information Piping Connection To The Units Align the center of the piping and sufficiently tighten the flare nut with fingers. Finally, tighten the flare nut with torque wrench until the wrench clicks. When tightening the flare nut with torque wrench, ensure the direction for tightening follows the arrow on the wrench. Pipe Size (mm/in) Torque (nm) 6.35 (1/4) (3/8) (5/8) 65 Vacuuming and Charging The precharged outdoor unit does not need any vacuuming or charging. However once it is connected, theconnecting pipe line and the indoor need to be vacuumed before releasing refrigerant from the outdoor unit. 1) Open the service port core cap. 2) Connect pressure gauge to the service port. 3) Connect the line to vacuum pump. Open the charging manifold valve and turn the pump on. Vacuum to -0.1MPa (-760mmHg) or lower. (Evacuation time varies by the pump but averagely in 1 hour). CHARGE SET Flare Valve INDOOR UNIT OUTDOOR UNIT LO HI Flare Joint CHARGE CYLINDER Diagram 1 13

15 Application Information A5HDC ) After evacuation, unscrew the spindle (diagram 2) for the gas to run to indoor unit. Diagram 2 The refrigerant gas has already charged into the outdoor unit. For the piping length of 5m. Additional refrigerant charge after vacuuming is not necessary. When the piping length is more than 5m, please use the table below (unit in gram). Model 7m 10m 15m A5HDC20AR A5HDC25AR CHARGE SET INDOOR UNIT Flare Valve OUTDOOR UNIT LO HI Flare Joint CHARGE CYLINDER 14

16 A5HDC-2009 Application Information Overall Checking Ensure the following, in particular :- 1) The unit is mounted solidly and rigid in position. 2) Piping and connections are leak proof after charging. 3) Proper wiring has been done. Drainage check - pour some water into drain pan. Test run 1) Conduct a test run after water drainage test and gas leakage test. 2) Watch out for the following :- a) Is the electric plug firmly inserted into the socket? b) Is there any abnormal sound from unit? c) Is there any abnormal vibrations with regard to unit itself or piping? d) Is there smooth drainage of water? Check that :- 1) Outdoor blower is running, with warm air blowing off the discharge grille (cooling cycle). 2) Indoor blower is running and discharge cool air (cooling cycle). 3) Suction (low side) pressure as recommended. 4) The remote controller incorporate a 3 minute delay in there circuit. Thus, it requires about 3minutes before the outdoor unit can start up. Standard Operating Condition Heatpump Temperature Ts C Th C minimum indoor temperature 15 - maximum indoor temperature minimum outdoor temperature -2-3 maximum outdoor temperature Ts : Dry bulb temperature Th : Wet bulb temperature 15

17 Application Information A5HDC-2009 Special Precautions When Dealing with Refrigerant R410A Unit (1) What is new refrigerant R410A? R410A is a new HFC refrigerant which does not damage the ozone layer. The working pressure of this new refrigerant is 1.6 times higher than conventional refrigerant (R22), thus proper installation / servicing is essential. (2) Components Mixture weight composition R32(50%) and R125(50%) (3) Characteristic R410A liquid and vapor components have different compositions when the fluid evaporates or condenses. Hence, when leak occurs and only vapor leaks out, the composition of the refrigerant mixture left in the system will change and subsequently affect the system performance. DO NOT add new refrigerant to leaked system. It is recommended that the system should be evacuated thoroughly before recharging with R410A. When refrigerant R410A is used, the composition will differ depending on whether it is in gaseous or liquid phase. Hence when charging R410A, ensure that only liquid is being withdrawn from the cylinder or can. This is to make certain that only original composition of R410A is being charged into the system. POE oil is used as lubricant for R410A compressor, which is different from the mineral oil used for R22 compressor. Extra precaution must be taken not to expose the R410A system too long to moist air. (4) Check list before installation / servicing Tubing Refrigerant R410A is more easily affected by dust of moisture compared with R22, make sure to temporarily cover the ends of the tubing prior to installation. Compressor oil No additional charge of compressor oil is permitted. Refrigerant No other refrigerant other that R410A Tool (size of service port is different from R22 system) Tools specifically for R410A only (must not be used for R22 or other refrigerant) i) Gauge manifold and charging hose ii) Gas leak detector iii) Refrigerant cylinder/charging cylinder iv) Vacuum pump c/w adapter v) Flare tools vi) Refrigerant recovery machine 16

18 A5HDC-2009 Application Information (5) Handling and installation guidelines Like R22 system, the handling and installation of R410A system are closely similar. All precautionary measures; such as ensuring no moisture, no dirt or chips in the system, clean brazing using nitrogen, and thorough leak check and vacuuming are equally important requirements. However, due to its hydroscopic POE oil, additional precautions must be taken to ensure optimum and trouble free system operation. (a) During installation or servicing, avoid prolong exposure of the internal part of the refrigerant system to moist air. Residual POE oil in the piping and components can absorb moisture from the air. (b) Ensure that the compressor is not exposed to open air for more than the recommended time specified by its manufacturer (typically less than 10 minutes). Removed the seal plugs only when the compressor is about to be brazed. (c) The system should be thoroughly vacuumed to 1.0 Pa (700mmHg) or lower. This vacuuming level is more stringent than R22 system so as to ensure no incompressible gas and moisture in the system. 17

19 Sound Data A5HDC-2009 Sound Data Sound Pressure Level Model A5CC20CR A5CC25CR Ext. Static 1/1 Octave A-Weighted Sound Pressure (dba), ref 20µPa Overall Speed Noise (mmaq) 125Hz 250Hz 500Hz 1kHz 2kHz 4kHz 8kHz A (dba) Criteria 6.5 High Medium Low High Medium Low Microphone position: 1.4m below the centre of the unit. (GB Standard- GB/ D17758) Tested with 2m length duct at the discharge outlet and air return inlet. Model Measuring Location A5CC20CR A5CC25CR 2m length test duct Test Unit 2m length test duct 1.4m Air Microphone Standard: GB/D

20 A5HDC-2009 Sound Data 70 A5CC20CR NC Curve 60 Sound pressure level (db, ref 20µPa) High fan Medium fan Low fan NC-50 NC-45 NC-40 NC-35 NC-30 NC Octave-band frequency (Hz) 70 A5CC25CR NC Curve 60 Sound pressure level (db, ref 20µPa) Medium fan High fan Low fan NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 NC Octave-band frequency (Hz) 19

21 Engineering and Physical Data A5HDC-2009 Engineering And Physical Data General Data - Heat Pump (R410A) MODEL INDOOR UNIT A5CC20CR A5CC25CR OUTDOOR UNIT A5HDC20AR A5HDC25AR NOMINAL COOLING CAPACITY NOMINAL HEATING CAPACITY Btu/h Btu/h W W NOMINAL TOTAL INPUT POWER (COOLING) NOMINAL TOTAL INPUT POWER (HEATING) NOMINAL RUNNING CURRENT (COOLING) NOMINAL RUNNING CURRENT (HEATING) POWER SOURCE EER W W A A V/Ph/Hz W/W /1/ /1/ REFRIGERANT TYPE R410A R410A REFRIGERANT CONTROL (EXPANSION DEVICE) OUTDOOR CAP. TUBE OUTDOOR CAP. TUBE CONTROL AIR DISCHARGE DUCTED DUCTED OPERATION SLM WIRED HANDSET SLM WIRED HANDSET AIR FLOW HIGH MEDIUM LOW l/s / CFM l/s / CFM l/s / CFM 330 / / / / / / 580 EXTERNAL STATIC PRESSURE (H/M/L) SOUND PRESSURE LEVEL (H/M/L) HEIGHT Pa / in.wg. dba mm/in 64 / 58 / 34 (0.3 / 0.2 / 0.1) 38 / 36 / / / 39 / 29 (0.2 / 0.2 / 0.1) 40 / 39 / / 10.3 UNIT DIMENSION PACKING DIMENSION UNIT WEIGHT WIDTH DEPTH HEIGHT WIDTH DEPTH mm/in mm/in mm/in mm/in mm/in kg/lb 1065 / / / / / / / / / / / / 55 CONDENSATE DRAIN SIZE AIR FLOW SOUND PRESSURE LEVEL HEIGHT mm/in l/s / CFM dba mm/in 19.1 / 3/4 640 / / / 3/4 600 / / 24.3 UNIT DIMENSION WIDTH DEPTH HEIGHT mm/in mm/in mm/in 703 / / / / / / 24.3 PACKING DIMENSION UNIT WEIGHT WIDTH DEPTH mm/in mm/in kg/lb 703 / / / / / / 269 TYPE FLARE VALVE FLARE VALVE PIPE CONNECTION LIQUID mm/in 6.4 / 1/4 6.4 / 1/4 SIZE GAS mm/in 12.7 / 1/ / 5/8 REFRIGERANT CHARGE kg/lb / / INDOOR UNIT OUTDOOR UNIT 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO ) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : COOLING - 27 C DB / 19 C WB INDOOR AND 35 C DB / 24 C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT. 20

22 A5HDC-2009 Engineering and Physical Data Components Data (R22) MODEL INDOOR FAN INDOOR FAN MOTOR OUTDOOR FAN OUTDOOR FAN MOTOR COMPRESSOR INDOOR COIL OUTDOOR COIL AIR QUALITY CASING INDOOR UNIT A5CC20CR OUTDOOR UNIT A5HDC20AR TYPE CENTRIFUGAL QUANTITY 2 MATERIAL GALVANIZED STEEL DRIVE DIRECT DIAMETER LENGTH TYPE mm/in mm/in 160 / / 7.95 INDUCTION QUANTITY 1 INDEX OF PROTECTION (IP) N/A TYPE CENTRIFUGAL (10" x8") QUANTITY 1 MATERIAL HOT DIP GALVANISED STEEL DRIVE DIRECT DIAMETER mm/in 380 / 15 TYPE SINGLE PHASE INDUCTION QUANTITY 1 INDEX OF PROTECTION (IP) IP00 TYPE ROTARY OIL TYPE OIL AMOUNT cm 3 / fl.oz. 470 / 15.9 TUBE FIN TUBE FIN FILTER MATERIAL DIAMETER mm/in 7.00 / THICKNESS mm/in 0.28 / MATERIAL THICKNESS mm/in 0.11 / FACE AREA m 2 /ft / DIAMETER mm/in 7.00 / THICKNESS mm/in 0.28 / THICKNESS mm/in / QUANTITY pc 1 LENGTH WIDTH THICKNESS mm/in mm/in mm/in MATERIAL FINISHING COLOUR MATERIAL FINISHING COLOUR RB68A OR FREOL ALPHA68M SEAMLESS INNER GROOVE COPPER ALUMINIUM (SLIT FIN) ROW 3 FIN PER INCH 18 MATERIAL MATERIAL SEAMLESS COPPER TUBE ALUMINIUM FACE AREA m 2 /ft / ROW 2 FIN PER INCH 19 TYPE SIZE INDOOR UNIT OUTDOOR UNIT WASHABLE SARANET FILTER 860 / / / 0.20 GALVANIZED STEEL WITH PE INSULATION WITHOUT POWDER PAINT GALVANIZED STEEL PAINTED LIGHT GREY A5CC25CR A5HDC25AR CENTRIFUGAL 2 GALVANIZED STEEL DIRECT 160 / / 7.95 INDUCTION 1 N/A CENTRIFUGAL (10" x8") 1 HOT DIP GALVANISED STEEL DIRECT 381 / 15 SINGLE PHASE INDUCTION 1 IP00 ROTARY RB68A OR FREOL ALPHA68M 700 / 23.7 SEAMLESS INNER GROOVE COPPER 7.00 / / ALUMINIUM (SLIT FIN) 0.11 / / SEAMLESS COPPER TUBE 7.00 / / ALUMINIUM / / WASHABLE SARANET FILTER / / / 0.20 GALVANIZED STEEL WITH PE INSULATION WITHOUT POWDER PAINT GALVANIZED STEEL PAINTED LIGHT GREY 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 21

23 Engineering and Physical Data A5HDC-2009 Safety Devices MODEL INDOOR UNIT OUTDOOR UNIT A5CC20CR A5HDC20AR A5CC25CR A5HDC25AR TYPE N/A N/A HIGH PRESSURE SWITCH OPEN kpa / psi N/A N/A CLOSE kpa / psi N/A N/A SAFETY DEVICE LOW PRESSURE SWITCH TYPE OPEN kpa / psi N/A N/A N/A N/A CLOSE kpa / psi N/A N/A PHASE SEQUENCER N/A N/A DISCHARGE THERMOSTAT SETTING C / F N/A N/A 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 22

24 A5HDC-2009 Performance Data Performance Data Interpolation and Extrapolation method can be used to get the total capacity, TC and sensible capacity, SC at those temperatures which are not stated out in the table. Example: Model: A5CC20CR - A5HDC20AR Indoor Condition: 23 C DB, 15 C WB Outdoor Condition: 37 C DB Solution: Overall Based on the Performance Table 1. Refer to the Indoor DB column, - 23 C is located between 20 C and 24 C (Thus, Interpolation need to be applied) 2. Refer to the Indoor WB column, - 15 C only available in the case of Indoor DB = 20 C. (Thus, Extrapolation between 16 C WB and 17 C WB during 24 C indoor DB is required) 3. Refer to the Outdoor DB column, - 37 C is located between 35 C and 40 C. (Thus, Interpolation need to be applied) Please follow the steps below in order to get the required capacity. 1 st Step Extrapolation of Indoor WB Find TC, SC for (a) Indoor: 24 C DB, 15 C WB Outdoor: 35 C DB (b) Indoor: 24 C DB, 15 C WB Outdoor: 40 C DB 2 nd Step Interpolation of Indoor DB Find TC, SC for (a) Indoor: 23 C DB, 15 C WB Outdoor: 35 C DB (b) Indoor: 23 C DB, 15 C WB Outdoor: 40 C DB 3 rd Step Interpolation of Outdoor DB Find TC, SC for (a) Indoor: 23 C DB, 15 C WB Outdoor: 37 C DB 23

25 Performance Data A5HDC-2009 Calculation Steps Details: 1 st Step: To obtain the Total capacity and Sensible capacity for (a) Indoor Condition: 24 C DB, 15 C WB Outdoor Condition: 35 C DB Indoor DB C 24 Total capacity, TC Indoor WB C Outdoor DB, C 35 TC (kw) SC (kw) x 1 y x 1 = 3.295kW (Same as Total capacity at 20 C Indoor DB / 15 C Indoor WB & 35 C Outdoor WB)* Sensible capacity, SC Extrapolation Method: 17º C 15º C 2.288kW y 1 = 17º C 16º C 2.228kW 2.381kW y 1 = 2.474kW (b) Indoor Condition: 24 C DB, 15 C WB Outdoor Condition: 40 C DB Indoor DB C 24 Indoor WB C Outdoor DB, C 40 TC (kw) SC (kw) x 2 y Total capacity, TC x 2 = 2.995kW (Same as Total capacity at 20 C Indoor DB / 15 C Indoor WB & 40 C Outdoor WB)* Sensible capacity, SC Extrapolation Method: 17º C 15º C 17º C 16º C = 1.954kW y kW 2.056kW y 2 = 2.158kW * This is due to 2 different conditions with same WB temperature, will have the same level of enthalpy. For more details, please refer to psychrometrics chart 24

26 A5HDC-2009 Performance Data 2 nd Step: To obtain the Total capacity and Sensible capacity for (a) Indoor Condition: 23 C DB, 15 C WB Outdoor Condition: 35 C DB Indoor DB C Indoor WB C Outdoor DB, C 35 TC (kw) SC (kw) x 3 y Total capacity, TC x 3 = 3.295kW (Same as Total capacity at 20 C Indoor DB / 15 C Indoor WB & 35 C Outdoor WB)* Sensible capacity, SC Interpolation Method: 24º C 20º C 2.474kW 1.510kW = 24º C 23º C 2.474kW y 3 y 1 = 2.233kW (b) Indoor Condition: 23 C DB, 15 C WB Outdoor Condition: 40 C DB Indoor DB C Indoor WB C Outdoor DB, C 40 TC (kw) SC (kw) x 4 y Total capacity, TC x 4 = 2.995kW (Same as Total capacity at 20 C Indoor DB / 15 C Indoor WB & 40 C Outdoor WB)* Sensible capacity, SC Interpolation Method: 24º C 20º C 2.158kW 1.195kW = 24º C 23º C 2.158kW - y 1 y 2 = 1.597kW * This is due to 2 different conditions with same WB temperature, will have the same level of enthalpy. For more details, please refer to psychrometrics chart 25

27 Performance Data A5HDC rd Step: To obtain the Total capacity and Sensible capacity for (a) Indoor Condition: 23 C DB, 15 C WB Outdoor Condition: 37 C DB Indoor DB C Indoor WB C Outdoor DB, C TC (kw) SC (kw) TC (kw) SC (kw) TC (kw) SC (kw) x y Total capacity, TC Interpolation Method: 40º C 35º C 2.995kW 3.295kW = 40º C 37ºC 2.995kW x x = 3.175kW Sensible capacity, SC Interpolation Method: 40º C 35º C = 40º C 37º C y = 2.107kW 1.917kW 2.233kW 1.917kW y 26

28 A5HDC-2009 Performance Data Performance Table Heatpump (R410A) Model: A5CC20CR - A5HDC20CR Cooling Mode ID DB C ID WB C Outdoor DB C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) Model: A5CC20CR - A5HDC20AR Heating Mode ID DB C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) FROST REGION Outdoor WB C

29 Performance Data A5HDC-2009 Model: A5CC25CR - A5HDC25AR Cooling Mode ID DB C ID WB C Outdoor DB C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) Model: A5CC25CR - A5HDC25AR Heating Mode ID DB C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) FROST REGION Outdoor WB C

30 A5HDC-2009 Outline and Dimension Outline and Dimension Indoor Unit Model: A5CC20/ 25CR Note: Dimension in mm Model A B C D E F G H A5CC20CR A5CC25CR

31 Outline and Dimension A5HDC-2009 Outdoor Unit Model: A5HDC20/ 25AR Note: Dimension in mm 30

32 A5HDC-2009 Electrical Data Electrical Data Electrical Data - Heatpump (R410A) MODEL INDOOR MOTOR OUTDOOR MOTOR COMPRESSOR INDOOR UNIT A5CC20CR OUTDOOR UNIT A5HDC20AR INSULATION GRADE CLASS E POWER SOURCE V/Ph/Hz /1/50 RATED INPUT POWER W 135 RATED RUNNING CURRENT A 0.60 MOTOR OUTPUT W 80 POLES 4 INSULATION GRADE POWER SOURCE V/Ph/Hz RATED INPUT POWER W RATED RUNNING CURRENT A CLASS F /1/ MOTOR OUTPUT W 375 POLES 6 INSULATION GRADE - POWER SOURCE V/Ph/Hz /1/50 CAPACITOR µf 50.0 RATED INPUT POWER (COOLING) W 1803 RATED INPUT POWER (HEATING) W 1573 RATED RUNNING CURRENT (COOLING) A 8.1 RATED RUNNING CURRENT (HEATING) A 7.5 LOCKED ROTOR AMP. A - A5CC25CR A5HDC25AR CLASS E /1/ CLASS F /1/ /1/ ) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE 31

33 Wiring Diagram A5HDC-2009 Wiring Diagram Heat Pump Indoor Unit Outdoor Unit Model: A5CC20CR Model: A5HDC20AR A5CC25CR A5HDC25AR

34 A5HDC-2009 Service and Maintenance Service and Maintenance Caution Disconnect From Main Supply Before Servicing The Air Conditioner The unit is designed to give a long life operation with minimum maintenance required. However, it should be regularly checked and the following items should be given due attention. Components Maintenance Procedure Recommended Schedule Indoor Air Filter 1. Remove any dust adhering on the filter by using avacuum cleaner or wash in lukewarm water (below 40 C/104 F) with a neutral cleaning detergent. 2. Rinse the filter well and dry before placing it back on to the unit. 3. Do not use gasoline, volatile substances or chemicals to clean the filter. At least once every 2 weeks. More frequently if necessary Indoor Unit 1. Clean any dirt or dust on the grille or panel by wiping it with a soft cloth soaked in lukewarm water (below 40 C/104 F) and a neutral detergent solution. 2. Do not use gasoline, volatile substances or chemicals to clean the indoor unit. At least once every 2 weeks. More frequently if necessary Condensate Drain Pan and Pipe 1. Check and clean. Every 3 months. Indoor Fan 1. Check for unusual noise. As necessary. Indoor/Outdoor Coil Electrical Compressor Compressor Lubrication 1. Check and remove dirt which are clogged between fins. 2. Check and remove obstacles which hinder air flow in and out of indoor/outdoor unit. 1. Check voltage, current and wiring. 2. Check faulty contacts caused by loose connections, foreign matters, etc. 1. No maintenance needed if refrigerant circuit remains sealed. However, check for refrigerant leak at joints and fittings. 1. Oil is factory charged. Not necessary to add oil if circuit remains sealed. Every month. Every month. Every 2 months. Every 2 months. Every 6 months. No maintenance required. Fan Motors Lubrication 1. All motors pre-lubricated and sealed at factory. No maintenance required. 33

35 Service and Maintenance A5HDC-2009 Pre Start Up Maintenance (After Extended Shut Down) - Inspect thoroughly and clean indoor and outdoor units. - Clean or replace air filters. - Clean condensate drain line. - Clean clogged indoor and outdoor coils. - Check fan imbalance before operation. - Tighten all wiring connections and panels. - Check for refrigerant leakage. Most of the parts are accessible by removal of bottom & side panel. Caution Do not charge OXYGEN, ACETYLENE OR OTHER FLAMMABLE and poisonous gases into the unit when performing a leakage test or an airtight test. These gases could cause severe explosion and damage if exposed to high temperature and pressure. It is recommended that only nitrogen or refrigerant be charged when performing the leakage or airtight test. 34

36 A5HDC-2009 Troubleshooting Troubleshooting Error Code Heatpump Model (Universal Board) Error Code at 7 Segment Display Blink E1 Blink E2 Blink E3 Blink E4 Blink E5 Blink E6 Blink Heat LED Operation / Faulty Indication Room sensor contact loose / short Indoor coil sensor contact loose Outdoor coil sensor contact loose Compressor overload / Indoor coil sensor short / Outdoor coil sensor short Gas leak N/A Outdoor defrost (for Heatpump ony) Fault Condition When any air-conditioner malfunction is noted, immediately switch off the power supply to the unit, and contact the local dealer, if necessary. Some simple troubleshooting tips are given below : Fault 1. Fan does not work 3 minutes after starting 2. The air conditioning unit does not work 3. The air conditioning unit does not blow sufficiently Cause Protection against the frequent starting. Wait 3 or 4 minutes. Power failure or need to replace the fuse. The power plug is disconnected. Possibility of making a programming error in the controller. If the fault persist after these verifications, contact your installer. The air filter is dirty. The doors or windows are open. The air entrance and exit are clogged. The regulate temperature is not high enough. 4. The remote control light is deficient The batteries are discharge. The batteries are not correctly inserted. The assembly is not good. 5. Air discharge flow has a bad odor This odor can be caused by cigarette smoke particles, perfume, sweat, which stick to the coil. Check if there is any moisture on the walls, garment, other. Check the drain pan. 6. Condensation on the air grille of indoor unit 7. The water flow of air conditioning unit This is due to air humidity after a long time of operation. The unit has a lower temperature point, increase the point and operate at high speed. Check the condensate evacuation. 8. The air conditioning unit are noisy Air flow noise : refrigerant fluid admission in evaporator. 35

37 Troubleshooting A5HDC-2009 Diagnostic Guidelines By means of pressure reading: Pressure Circuit Data Too low A little low Normal A little high Too high Probable cause High side Low side High side Low side 1. Overcharged with refrigerant. 2. Non-condensable gases in refrigerant circuit (e.g. air) 3. Obstructed air-intake / discharge. 4. Hot air short circuiting in outdoor unit. 1. Poor compression / no compression (compressor defective) 2. Reversing valve leaking. High side Low side 1. Undercharged with refrigerant. 2. Refrigerant leakage. 3. Air filter clogged / dirty (indoor unit). 4. Indoor fan locked / seized. 5. Defective defrost control, outdoor coil freeze up (heating). 6. Outdoor fan locked / seized (heating). High side Low side High side Low side 1. Outdoor fan blocked (cooling). 2. Outdoor coil dirty (cooling). 3. Indoor fan locked / seized (heating). 4. Indoor air filter clogged / dirty (heating). 5. Non-condensable gases in refrigerant circuit (e.g. air) 1. Air intake temperature of indoor unit too high. 36

38 A5HDC-2009 Troubleshooting By means of diagnostic flow chart: The following chart are efficient checking procedures for troubleshooting when these fan coil units, are coupled with the condensing units using standard wiring. For dual circuited models, perform the procedures for each circuit. No Cooling : Faulty : Check : Cause : Remedy No Cooling ( Compresor Does Not Start ) Evaporator Fan Motor Stop Unit Power Supply Faulty No Voltage or Low Voltage Single Phase Get The Right Voltage Repait The Power Line Running Fuse For Operation Circuit Overcurrent Relay For Evaporator Fan Blown Tripped Components Shorted Connections Loose High or Low Voltage Single Phase Repair or Replace The Components Tighten The Connections Get The Right Voltage Check The Power Supply To The Motor : Repair When Necessary Evaporator Fan Contactor Faulty Coil Burnt Contact Faulty Change The Contactor Repair The Contacts Faulty Fan Motor Repair Or Change The Motor Defective Operation Switch Repair Or Replace The Switch Condenser Fan Motor Stop Overcurrent Relay For Condenser Fan Tripped High Voltage or Low Voltage Single Phase Get The Right Voltage Check The Power Supply To The Motor : Repair When Necessary Running Condenser Fan Contactor Faulty Coil Burnt Contact Faulty Change The Contactor Change The Contacts Fan Motor Faulty Repair or Change The Motor Other Electrical Component Faulty Repair or Change If Necessary Compressor Contactor Faulty Coil Burnt Contact Faulty Change The Contactor Change The Contacts Open Compressor Windings Change The Compressor Incorrect Wiring Correct The Wiring 37

39 Troubleshooting A5HDC-2009 Insufficient Cooling Insufficient Cooling Compressor Cycling Cycling On Dual Pressure Switch Tripping High Discharge Pressure or Low Suction Pressure Clogged Capillary or Pressure Switch Switch Faulty See "High Discharge Pressure" or "Low Suction Pressure" Repair Clogging and Replace The Switch If Required Repair or Change If Necessary Running Overcurrent Relay For Compressor Discharge Gas Thermostat or Internal Thermostat Tripping Tripping High Voltage or Low Voltage Single-Phase High Discharge Pressure And High Suction Pressure Loose Connections High Discharge Pressure And Low Suction Pressure Refrigerant Short Charge or Refrigerant Leakage Get The Right Voltage Check The Power Line To The Compressor : Repair When Necessary See "High Discharge Pressure" or "High Suction Pressure" Tighten The Connections See "High Discharge Pressure" or "Low Suction Pressure" Add Refrigerant. Repair Leakage If Detected. High Suction Pressure... See "High Suction Pressure" High Discharge Pressure or Low Suction Pressure... See "High Discharge Pressure" or "Low Suction Pressure" High Discharge Pressure High Discharge Pressure Condenser Air Flow Restricted Clogged Condenser Coil Low Fan Speed Clean The Condenser Check The Voltage And Get The Right Voltage Condenser Air Inlet Temperature High Malfunction Of Fan Cycling System Circulating Air Flow Overcharged Refrigerant Check The System And Repair If Required Secure Space For Required Air Flow Purge The Refrigerant Non-Condensable Gas... Purge The Gas Restricted Liquid Line... Remove The Restriction High Suction Pressure... See "High Suction Pressure" Low Discharge Pressure Low Discharge Pressure Condenser Air Flow Excessive Malfunction Of Fan Cycling System Low Refrigerant Charge Check The System And Repair The Components If Required Add Refrigerant Low Ambient Temperature... See The Unit Working Range 38

40 A5HDC-2009 Troubleshooting High Suction Pressure High Suction Pressure Evaporator Air Inlet Temperature Low Excessive Fresh Air Intake Insufficient Duct Insulation Defective Compressor Valve Reduce The Fresh Air Intake Reinforce The Duct Insulation Change Or Repair The Compressor Overcharged Refrigerant... Purge The Refrigerant Low Suction Pressure Low Suction Pressure Evaporator Air Flow Evaporator Air Inlet Temperature Restricted Low Clogged Air Filter Restricted Duct Low Fan Speed Short Cycling Faulty Thermostat Clean The Air Filter Remove The Restriction Adjust The Fan Speed Remove Obstacles To Air Circulation Repair Or Replace If Necessary Restricted Liquid LIne And Suction Line... Remove The Restriction Low Refrigerant Charge... Add Refrigerant Low Discharge Pressure... See "Low Discharge Pressure" Noisy Operation Noisy Operation Compressor Noisy Shipping Bolt(s) Liquid Refrigerant Backing Up Noisy Unremoved Shipping Bolt(s) Overcharged Refrigerant Low Suction Pressure Worn Compressor Parts Remove The Bolt(s) Purge The Refrigerant See "Low Suction Pressure" Replace Or Repair The Compressor Evaporator Fan Liquid Line Noisy Noisy Strainer Whistling Knocking Runner Worn Bearing Partially Clogged Refrigerant Short Charge... Fix The Runner Or Casing Properly Change The Bearing Clean The Dryer Add Refrigerant Loose Fixed Screws Inadequate Duct Work Tighten All Fixed Screws Check Flexible Ducts 39

41 Exploded View and Part List A5HDC-2009 Exploded View and Part List Indoor Unit Model: A5CC20/ 25CR No Description Part No No Description Part No 1 Cabinet 7 - A5CC20CR R Parts not in diagram A5CC25CR R A Assy. Wheel & Housing - Left R Fan Deck B Assy. Wheel & Housing - Right R A5CC20CR R C Fan Motor A5CC25CR R A5CC20C R Assy. Coil A5CC25CR R A5CC20CR R D Air Filter A5CC25CR R A5CC20C R Primary Drain Pan A5CC25CR R A5CC20CR R E Assy. Drain Pipie Join R A5CC25CR R F L2 Control Module 5 Secondary Drain Pan A5CC20CR R A5CC20CR R A5CC25CR R A5CC25CR R G SLM Handset R Hanger R Note: All exploded view and part list are subjected to change by the manufacturer without prior notice 40

42 A5HDC-2009 Exploded View and Part List Outdoor Unit Model: A5HDC20AR No Description No Description 1 Assy. Front Panel 12 Assy. 4-Way Valve 2 Assy. Drain Pan 13 Tube (Comp. Suct. To Acc. Out) 3 Assy. Base Panel 14 Blower 4 Assy. Coil 15 Fan Motor 5 Compressor Jacket 16 Bracket, Fan Motor 6 Hanging Bracket 17 Top Panel 7 Back Panel 18 Duct, Flange 8 Compressor 19 Service Panel 9 Assy. Flare Valve, 1/2" 20 Terminal Box 10 Assy. 2-Way Valve, 1/4" 21 Terminal Box Cover 11 Accumulator Note: All exploded view and part list are subjected to change by the manufacturer without prior notice 41

43 Exploded View and Part List A5HDC-2009 Outdoor Unit Model: A5HDC25AR No Description No Description 1 Assy. Front Panel 12 Assy. 4-Way Valve 2 Assy. Drain Pan 13 Tube (Comp. Suct. To Acc. Out) 3 Assy. Base Panel 14 Blower 4 Assy. Coil 15 Fan Motor 5 Compressor Jacket 16 Bracket, Fan Motor 6 Hanging Bracket 17 Top Panel 7 Back Panel 18 Duct, Flange 8 Compressor 19 Service Panel 9 Assy. Flare Valve, 5/8" 20 Terminal Box 10 Assy. 2-Way Valve, 1/4" 21 Terminal Box Cover 11 Accumulator Note: All exploded view and part list are subjected to change by the manufacturer without prior notice 42

44 While upmost care is taken in ensuring that all details in the publication are correct at time of going to press, we are constantly striving for improvement and therefore reserve the rights to alter model specifications and equipment without prior notice. Details of specifications and equipment are also subject to change to suit local conditions and requirements and not all models are available in every market.

Models: ACC 75D/DR ACC 100D/DR. ACC - D (Draft) Ceiling Concealed Split Systems

Models: ACC 75D/DR ACC 100D/DR. ACC - D (Draft) Ceiling Concealed Split Systems Models: ACC 75D/DR ACC 100D/DR ACC - D2-2007 (Draft) Ceiling Concealed Split Systems CONTENTS 1. NOMENECLATURE... 2 2. FEATURES... 4 3. PRODUCT LINE UP... 5 4. SPECIFICATIONS... 8 5. OPERATING RANGE...

More information

Wall Mounted Split Systems

Wall Mounted Split Systems MWM - 2005 Wall Mounted Split Systems Models: MWM 007F/FR MWM 010F/FR MWM 015F/FR MWM 020F/FR MWM 025F/FR MWM 030F/FR Contents Features... 1 Nomenclature... 2 Specifications... 3 Performance Table... 11

More information

Amendment Sheet. Nomenclature M 5 AC V 100 C R - F X AA. Code : M5ACV Date : Superceded : M5ACV

Amendment Sheet. Nomenclature M 5 AC V 100 C R - F X AA. Code : M5ACV Date : Superceded : M5ACV Amendment Sheet Code : M5ACV-2005-0002 Date : 08-05-2006 Superceded : M5ACV-2005-0001 Nomenclature Production spec variation Type of ref. connection X : Not applicable Electrical A : 220-240V/1Ph/50Hz

More information

Contents. 1. Features Specifications Noise Level Operating Range Refrigeration Cycle Diagram...

Contents. 1. Features Specifications Noise Level Operating Range Refrigeration Cycle Diagram... AWMX-2004 Contents 1. Features... 1 2. Specifications... 2 3. Noise Level... 3 4. Operating Range... 5 5. Refrigeration Cycle Diagram... 6 6. Outlines and Dimensions... 7 7. Wiring Diagrams... 8 8. Safety

More information

INSTALLATION MANUAL. Model UAT150CGXY1 UAT180CGXY1 UAT240CGXY1 UAT300CGXY1 UAT150CGXY19 UAT180CGXY19 UAT240CGXY19 UAT300CGXY19.

INSTALLATION MANUAL. Model UAT150CGXY1 UAT180CGXY1 UAT240CGXY1 UAT300CGXY1 UAT150CGXY19 UAT180CGXY19 UAT240CGXY19 UAT300CGXY19. INSTALLATION MANUAL Installation Manual Rooftop Package Air Conditioner English Model UAT50CGXY UAT80CGXY UAT20CGXY UAT300CGXY UAT50CGXY9 UAT80CGXY9 UAT20CGXY9 UAT300CGXY9 IM-RTC-072(0)-DAIKIN Part No.:

More information

R407C TECHNICAL MANUAL. Packaged Air Conditioner Rooftop A series. UATP-A and UATYP-A Series. Cooling only & Heatpump [50Hz]

R407C TECHNICAL MANUAL. Packaged Air Conditioner Rooftop A series. UATP-A and UATYP-A Series. Cooling only & Heatpump [50Hz] R407C TECHNICAL MANUAL Packaged Air Conditioner Rooftop A series UATP-A and UATYP-A Series Cooling only & Heatpump [50Hz] Table of Contents Table of Contents Nomenclature...1 Product Line-Up...2 Application

More information

INSTALLATION MANUAL AIR COOLED, DUCTED SPLIT TYPE AIR-CONDITIONERS SPLIT TYPE. Part No.:R IM-MHSB-0806-DAIKIN

INSTALLATION MANUAL AIR COOLED, DUCTED SPLIT TYPE AIR-CONDITIONERS SPLIT TYPE. Part No.:R IM-MHSB-0806-DAIKIN INSTALLATION MANUAL AIR COOLED, DUCTED SPLIT TYPE AIR-CONDITIONERS SPLIT TYPE 18 Part No.:R08019028859 IM-MHSB-0806-DAIKIN OUTLINE AND DIMENSIONS FD75BV1M / FD100BV1M English FD125BY1M / FD150BY1M 1 FD200B2Y1M

More information

Horizontal Water Source Heat Pumps And Cooling Only Unit

Horizontal Water Source Heat Pumps And Cooling Only Unit MWH-B-2005 Horizontal Water Source Heat Pumps And Cooling Only Unit Models: MWH MWH MWH MWH MWH 011 B/BR MWH 012 B/BR MWH 015 B/BR MWH 020 B/BR MWH 025 B/BR MWH 030 B/BR 040 B/BR 050 B/BR 060 B/BR 070

More information

2. FEATURES. Gold aluminum fin is offered as standard material of the condenser heat exchanger of this series of chiller.

2. FEATURES. Gold aluminum fin is offered as standard material of the condenser heat exchanger of this series of chiller. 2. FEATURES TRUE DUAL CIRCUITS BPHE The true dual BPHE puts the secondary circuit (water) in contact with 2 primary circuits (refrigerant). So even if one primary circuit is shut off, each secondary channel

More information

Models: A5LCY 30 ER A5LCY 40 ER A5LCY 50 ER A5LCY 60 ER A5LCY - II Inverter Y Single Split Series II

Models: A5LCY 30 ER A5LCY 40 ER A5LCY 50 ER A5LCY 60 ER A5LCY - II Inverter Y Single Split Series II Models: A5LCY 30 ER A5LCY 40 ER A5LCY 50 ER A5LCY 60 ER A5LCY - II - 2010 Inverter Y Single Split Series II Table of Contents A5LCY-II-2010 Table of Contents Nomenclature...1 Indoor Unit...1 Outdoor Unit...2

More information

FWC02AAFNMV1 FWC03AAFNMV1 FWC04AAFNMV1 FWC05AAFNMV1 FWC06AAFNMV1

FWC02AAFNMV1 FWC03AAFNMV1 FWC04AAFNMV1 FWC05AAFNMV1 FWC06AAFNMV1 INSTALLATION MANUAL Installation manual Chilled Water Fan Coil Units English Models FWC02AAFNMV1 FWC03AAFNMV1 FWC04AAFNMV1 FWC05AAFNMV1 FWC06AAFNMV1 OUTLINE AND DIMENSIONS Indoor Unit: FWC02AAFNMV1 /

More information

DUCTED AIR CONDITIONER. Owner s Manual. KD Series KD24. Kaden Owner s Manual 1

DUCTED AIR CONDITIONER. Owner s Manual. KD Series KD24. Kaden Owner s Manual 1 DUCTED AIR CONDITIONER Owner s Manual KD Series KD24 Kaden Owner s Manual 1 Table of Contents 1. Safety Precautions 4 2. Indoor Unit Parts and Major Functions 6 3. Care and Maintenance 8 4. Troubleshooting

More information

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL TECHNICAL DATA & SERVICE MANUAL OUTDOOR UNIT: GRF188R5TAA GRF228R5TAA GRF228R7TAA SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. GRF188R5TAA 38.7107.083 GRF228R5TAA 38.7107.084 GRF228R7TAA 38.7107.085

More information

Room Air Conditioner Service and Parts Manual

Room Air Conditioner Service and Parts Manual Cool Dry Temp Mode Room Air Conditioner Service and Parts Manual F Fan Speed hr Timer 0n 0ff Money Saver Fan Only Auto Swing Power CP06 CP08 93011401_01 CONTENTS 1. PREFACE 1.1 SAFETY PRECAUTIONS...2 1.2

More information

DAIKIN ROOM AIR CONDITIONER. Operation Manual

DAIKIN ROOM AIR CONDITIONER. Operation Manual DAIKIN ROOM AIR CONDITIONER Operation Manual FDXM25F2V1B FDXM50F2V1B FDXM35F2V1B FDXM60F2V1B CONTENTS READ BEFORE OPERATION Safety precautions... 2 Names of parts... 4 CARE Care and Cleaning... 6 TROUBLE

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : CU-3KE19NBU CU-4KE24NBU CU-4KE31NBU DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity at 0V 19,100 BTU/h,200 BTU/h 30,600 BTU/h Outdoor Model No. CU-3KE19NBU CU-4KE24NBU

More information

INVERTER Y SINGLE SPLIT SERIES II

INVERTER Y SINGLE SPLIT SERIES II TECHNICAL MANUAL -0005 Supercedes -0004 INVERTER Y SINGLE SPLIT SERIES II Models: M5CKY28ER M5CCY28CR M5CMY28ER M5CKY40ER M5CCY38CR M5CMY40ER M5CKY50ER M5CCY50CR M5CMY50ER M5CCY60CR M5CMY62CR Table of

More information

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER Owner s Manual Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 IMPORTANT NOTE: Read this manual carefully before installing

More information

Your Climate. We're There. TM: MDB B 2140B. Ducted Split Systems. Models: MDB 075B - MDB750B MDB 075B/B - MDB500BR. Air Conditioning REGISTERED

Your Climate. We're There. TM: MDB B 2140B. Ducted Split Systems. Models: MDB 075B - MDB750B MDB 075B/B - MDB500BR. Air Conditioning REGISTERED Your Climate. We're There. TM: MDB B 2140B Ducted Split Systems Models: MDB 075B - MDB750B MDB 075B/B - MDB500BR REGISTERED Air Conditioning Contents Nomenclature System... 2 Features... 2 General Specifications...3-5

More information

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL TECHNICAL DATA & SERVICE MANUAL OUTDOOR UNIT: AE726SCL AE752SCL AE71SCL3 AE735SCL AE752SCL3 AE100SCL3 AE764SCL3 AE125SCL3 SPLIT SYSTEM AIR CONDITIONER Model No. AE726SCL AE735SCL AE752SCL AE752SCL3 AE764SCL3

More information

SERVICING PROCEDURE R-410A LEAK TEST EVACUATION CHARGING. Bard Manufacturing Company, Inc. Bryan, Ohio Manual Page 1 of 11

SERVICING PROCEDURE R-410A LEAK TEST EVACUATION CHARGING. Bard Manufacturing Company, Inc. Bryan, Ohio Manual Page 1 of 11 SERVICING PROCEDURE R-410A LEAK TEST EVACUATION CHARGING Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since 1914...Moving ahead, just as planned. Manual No.: 2100-479 Supersedes: NEW File: Volume

More information

LOW STATIC HYDRONIC DUCTED UNIT

LOW STATIC HYDRONIC DUCTED UNIT LOW STATIC HYDRONIC DUCTED UNIT PDWA-~AC SERIES PDWA(4R)-~-V-MEDC PDWA(4R)-~-V-MEEU PDWA(R)-~-V PDWA(R+1)-~-P Model cooling capacity( KW) at Medium Speed cooling capacity (KW) at Medium Speed cooling capacity

More information

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A Revision B: MUZ-GL09NA- U8 and MUZ-GL09NAH- U8 have been added. Please void OBH733 REVISED EDITION-A. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A. OBH733 REVISED EDITION-B Models MUZ-GL09NA

More information

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A TECHNICAL & SERVICE MANUAL SA 183A FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. SA-183A 1 851 006 96 Destination Australia SA 183A REFERENCE NO. SM700514 IMPORTANT! Please Read Before

More information

Models: A5ACV 30 CR A5ACV 55 CR A5ACV 75 CR A5ACV 100 CR A5ACV 135 CR A5ACV 210 CR A5ACV Air-Cooled Chiller (R410A Inverter Series)

Models: A5ACV 30 CR A5ACV 55 CR A5ACV 75 CR A5ACV 100 CR A5ACV 135 CR A5ACV 210 CR A5ACV Air-Cooled Chiller (R410A Inverter Series) Models: A5ACV 30 CR A5ACV 55 CR A5ACV 75 CR A5ACV 100 CR A5ACV 135 CR A5ACV 10 CR A5ACV - 007 Air-Cooled Chiller (R410A Inverter Series) 1. NOMENCLATURE Production spec variation Type of ref. connection

More information

Owner s Manual Super-Slim Four-Way Cassette

Owner s Manual Super-Slim Four-Way Cassette CASSETTE- TYPE AIR CONDITIONER Owner s Manual Super-Slim Four-Way Cassette IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this

More information

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624. SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH624 REVISED EDITION-A Models MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE

More information

YC ON-OFF SERIES. Service Manual

YC ON-OFF SERIES. Service Manual YC ON-OFF SERIES Service Manual CONTENTS 1. Precaution... 3 1.1 Safety Precaution... 3 1.2 Warning... 3 2. Model Lists... 6 3. Dimension... 7 3.1 Indoor Unit... 7 3.2 Outdoor Unit... 11 4. Refrigerant

More information

Inverter Split-type Room Air Conditioner

Inverter Split-type Room Air Conditioner OWNER S MANUAL Inverter Split-type Room Air Conditioner Please read the operating instructions and safety precautions carefully and thoroughly before installing and operating your room air conditioner.

More information

KSD-35 DR11 KUE-35 DVN11

KSD-35 DR11 KUE-35 DVN11 FLOOR-STANDING TYPE AIR CONDITIONER Owner s Manual Floor-Standing Type KSD-35 DR11 KUE-35 DVN11 IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit.

More information

Wall Mounted Split Systems

Wall Mounted Split Systems Catalog MWM - G - 2007 Wall Mounted Split Systems Models: MWM 007G/GR MWM 009G/GR MWM 010G/GR MWM 015G/GR MWM 020G/GR MWM 025G/GR MWM 030F/FR M5WM 007G/GR M5WM 009G/GR M5WM 010G/GR M5WM 015G/GR M5WM 020G/GR

More information

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513 TECHNICAL & SERVICE MANUAL SA 123A FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. Destination SA-123A 1 851 006 95 Australia SA 123A REFERENCE NO. SM700513 IMPORTANT! Please Read Before

More information

GENERAL 2004 HVAC SYSTEMS. Manual HVAC System - Sorento SPECIFICATIONS. Fig. 1: Air Conditioner Specifications Courtesy of KIA MOTORS AMERICA, INC.

GENERAL 2004 HVAC SYSTEMS. Manual HVAC System - Sorento SPECIFICATIONS. Fig. 1: Air Conditioner Specifications Courtesy of KIA MOTORS AMERICA, INC. Fig. 2: Blower & Evaporator Unit Specifications 2004 HVAC SYSTEMS Manual HVAC System - Sorento GENERAL SPECIFICATIONS AIR CONDITIONER Fig. 1: Air Conditioner Specifications BLOWER AND EVAPORATOR UNIT HEATER

More information

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions INSPECTION When the equipment is received, all items should be carefully checked against the bill

More information

Owner s Manual INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

Owner s Manual INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER Owner s Manual IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure

More information

AUTO COOL DRY FAN SPEED AIR SWING OFF ON TIMER TIMER OFF/ON FAN SPEED MODE TEMP AIR SWING TIMER ON SET OFF CANCEL AC RC SET CHECK CLOCK RESET

AUTO COOL DRY FAN SPEED AIR SWING OFF ON TIMER TIMER OFF/ON FAN SPEED MODE TEMP AIR SWING TIMER ON SET OFF CANCEL AC RC SET CHECK CLOCK RESET AUTO COOL DRY MODE TIMER ON OFF TIMER OFF/ON TEMP ON TIMER FAN SPEED AIR SWING SET 1 2 3 FAN SPEED AIR SWING OFF CANCEL AC RC SET CHECK CLOCK RESET Order No: PAPAMY1611008CE Indoor Unit CS-MPS9SKH CS-MPS12SKH

More information

Split Portable Air Conditioner

Split Portable Air Conditioner SP-IOM-1 Please read and save this manual. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information.

More information

Owner s Manual INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

Owner s Manual INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER Owner s Manual IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure

More information

INVERTER ONE-TWO/ONE-THREE/ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

INVERTER ONE-TWO/ONE-THREE/ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER INVERTER ONE-TWO/ONE-THREE/ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER Owner s Manual Model: 3554190/3554191/3554192/3554193 3554194/3554195/3554196/3554197 IMPORTANT NOTE: Read this manual carefully

More information

NEXXOS INVERTER USER MANUAL

NEXXOS INVERTER USER MANUAL NEXXOS INVERTER USER MANUAL NIN412C2V32 NIN415C2V32 NIN520C2V32 NIN725C2V32 INVERTER MINI SPLIT SYSTEM WARNING The information contained in the manual is intended for use by a qualified service technician

More information

Split Water Source Heat Pump And Cooling Only Unit

Split Water Source Heat Pump And Cooling Only Unit CMWSC - 2004 Split Water Source Heat Pump And Cooling Only Unit Models: MWSC 010 A/AR MWSC 015 A/AR MWSC 020 A/AR MWSC 025 A/AR MWSC 030 A/AR MWSC 050 A/AR Contents Page Features... 1 Specifications...

More information

OWNER S MANUAL KPD-105 DTN11 KPD-140 DVN11 KPD-140 DTN11 KPD-160 DTN11 KPD-52 DVR11

OWNER S MANUAL KPD-105 DTN11 KPD-140 DVN11 KPD-140 DTN11 KPD-160 DTN11 KPD-52 DVR11 OWNER S MANUAL A6 Duct KPD-35 DVN11 KPD-52 DVN11 KPD-71 DVN11 KPD-90 DVN11 KPD-105 DVN11 KPD-105 DTN11 KPD-140 DVN11 KPD-140 DTN11 KPD-160 DTN11 KPD-52 DVR11 KPD-71 DVR11 KPD-105 DVR11 KPD-105 DTR11 KPD-140

More information

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC AQB8J6WC_IM_E_25864 2006.4.4 3:29 PM Page 7 INSTALLATION MANUAL Indoor Unit AQB8J6WC AQB24J2WC Outdoor Unit UQB8J6WC UQB24J2WC ENGLISH FRANÇAIS ESPAÑOL Split-type Air Conditioner (Cooling and Heating)

More information

TECHNICAL MANUAL. PACKAGED AIR-CONDITIONER (Split system, Air to air heat pump type) MULTI-TYPE (V-MULTI) PACKAGED AIR-CONDITIONER

TECHNICAL MANUAL. PACKAGED AIR-CONDITIONER (Split system, Air to air heat pump type) MULTI-TYPE (V-MULTI) PACKAGED AIR-CONDITIONER Manual No. '06 PAC, KX-T-110 TECHNICAL MANUAL Collection data PACKAGED AIR-CONDITIONER (Split system, Air to air heat pump type) FDUMVA201HEN2R 251HEN2R 302HEN2R 402HEN2R 502HEN2R 602HEN2R MULTI-TYPE (V-MULTI)

More information

Service Manual & Installation Manual

Service Manual & Installation Manual GE Consumer & Industrial Appliances Service Manual & Installation Manual Split System Air Conditioner Model numbers: GE AIR F24 GE AIR F34 GE AIR F41 1 2 3 Introduction and Features Model Remarks GE AIR

More information

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC Revision A: MUZ-HM09/12NA- U8, MUZ-HM09/12NA2- U8, MUZ-HM15/18NA- U1, MUZ-HM15/18NA2- U1 and MUZ-HM24NA2- U1 have been added. Please void OBH747. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A.

More information

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC AQB09JJ6WC_IM_E_2585 2006.4.17 4:26 PM Page 17 INSTALLATION MANUAL Indoor Unit AQB09JJWC AQB12JJWC Outdoor Unit UQB09JJWC UQB12JJWC ENGLISH FRANÇAIS ESPAÑOL Split-type Air Conditioner (Cooling and Heating)

More information

MODEL: ACWD CEILING CONCEALED Chilled Water Fan Coils Unit

MODEL: ACWD CEILING CONCEALED Chilled Water Fan Coils Unit MODEL: ACW200D ACW300D ACW400D ACW500D ACW600D ACW800D ACW900D ACW1000D ACW1200D ACW1400D ACWD-2006 ACWD_2006_Cover.indd 1 CEILING CONCEALED Chilled Water Fan Coils Unit 2006-5-25 17:24:07 Contents Main

More information

38GL...G / 38GLS...G 38YY...G / 38YYS...G

38GL...G / 38GLS...G 38YY...G / 38YYS...G LLOYD'S REGISTER QUALITY ASSURANCE 38GL...G / 38GLS...G 38YY...G / 38YYS...G I S O 9 00 1 INSTALLATION MANUAL 38GL...G / 38GLS...G / 38YY...G / 38YYS...G Cooling only and heat pump split system outdoor

More information

MULTI-SPLIT SYSTEM AIR CONDITIONER / HEAT PUMP. YN-M Series. Inverter++ Models. Two, Three, Four, and Five Zones (Dual, Triple, Quad, and Quint Multi)

MULTI-SPLIT SYSTEM AIR CONDITIONER / HEAT PUMP. YN-M Series. Inverter++ Models. Two, Three, Four, and Five Zones (Dual, Triple, Quad, and Quint Multi) MULTI-SPLIT SYSTEM AIR CONDITIONER / HEAT PUMP YN-M Series Inverter++ Models Two, Three, Four, and Five Zones (Dual, Triple, Quad, and Quint Multi) Owner s Manual IMPORTANT NOTICE: Read through and fully

More information

AC Portable Air Conditioner AC-14100E, AC-14100H OWNERS MANUAL. Read and save these instructions.

AC Portable Air Conditioner AC-14100E, AC-14100H OWNERS MANUAL. Read and save these instructions. AC-14100 Portable Air Conditioner AC-14100E, AC-14100H OWNERS MANUAL Read and save these instructions. 2 A Name You Can Trust Trust has to be earned and we will earn yours. Customer happiness is the focus

More information

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH Revision D: Capacity corrections have been corrected [7-1. 2), 3)]. OBH684 REVISED EDITION-C is void. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH684 REVISED EDITION-D Models MUZ-FH06NA MUZ-FH09NA

More information

R32. Installation Manual Split Type Wall Mounted Air Conditioner. This appliance shall be installed in accordance with: REFRIGERANT

R32. Installation Manual Split Type Wall Mounted Air Conditioner. This appliance shall be installed in accordance with: REFRIGERANT SWING LRSWING Installation Manual Split Type Wall Mounted Air Conditioner COOL RUN C SPEED TURBO ON/OFF FAN COOL HEAT SWING SWING Rinnai Systems Models System Indoor Outdoor HSNRQ25B HINRQ25B HONRQ25B

More information

WINDOW TYPE ROOM AIR CONDITIONER OPERATION AND INSTALLATION MANUAL

WINDOW TYPE ROOM AIR CONDITIONER OPERATION AND INSTALLATION MANUAL MODEL RA-0LDF RA-3LDF WINDOW TYPE ROOM AIR CONDITIONER OPERATION AND INSTALLATION MANUAL AIR DEFLECTORS VERTICAL DEFLECTORS Vertical de ectors at both sides of outlets can be set to either auto-swing or

More information

WINDOW YORK TECHNICAL GUIDE. Single package Cooling only and Heat pump. Models YO-YM R407C YO V6 G YO V7 G

WINDOW YORK TECHNICAL GUIDE. Single package Cooling only and Heat pump. Models YO-YM R407C YO V6 G YO V7 G WINDOW TECHNICAL GUIDE Single package Cooling only and Heat pump Models YO-YM 09-24 R407C YM 09 V6 G YM 09 V7 G YO 12-19-24 V6 G YO 12-19-24 V7 G YORK List of Contents Page 1 - Safety...2 2 - Unit packaging...2

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV 50 CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available November 2007 10 12 167 - GB -

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : CLM97 CLM7 CLM7 FILE NO. Destination: North America DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity at 0V 9,700 BTU/h,00 BTU/h 0,600 BTU/h Outdoor Model No.

More information

51AKS I S O OWNER S MANUAL

51AKS I S O OWNER S MANUAL LLOYD'S REGISTER QUALITY ASSURANCE 51AKS I S O 9 00 1 OWNER S MANUAL This manual applies to the following models Stand-alone Split 51AKS 085--- 51AKS 010--- 51AKS 185--- 51AKS 013--- 51AKS 113--- 51AKS

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw CHGV 22 CHGV 2 CHGV 32 CHGV 40 PHRV heat pump model also available September 2007 10 12 11 - GB - 02

More information

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC Revision D: MUFZ-KJ25VE - E2, ER2, ET2, MUFZ- KJ35VE - E2, ER2, ET2 and MUFZ- KJ50VE - E2, ER2, ET2 have been added. Please void OBH667 REVISED EDITION-C. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A.

More information

SERVICE MANUAL OUTDOOR UNIT. No. OBH789

SERVICE MANUAL OUTDOOR UNIT. No. OBH789 OUTDOOR UNIT SERVICE MANUAL HFC utilized R32. Models MUZ-AP25VG - E1, ET1 MUZ-AP25VGH - E1 MUZ-AP35VG - E1, ET1 MUZ-AP35VGH - E1 MUZ-AP42VG - E1, ET1 MUZ-AP42VGH - E1 MUZ-AP50VG - E1, ET1 MUZ-AP50VGH -

More information

PORTABLE AIR CONDITIONER (LOCAL)

PORTABLE AIR CONDITIONER (LOCAL) EN PORTABLE AIR CONDITIONER (LOCAL) OPERATING INSTRUCTIONS Read the instructions carefully before operating the appliance or carrying out maintenance work. Observe all the safety instructions; failure

More information

TECHNICAL MANUAL CX(E) SPLIT SYSTEMS. Tel: Fax:

TECHNICAL MANUAL CX(E) SPLIT SYSTEMS. Tel: Fax: TECHNICAL MANUAL CX(E) SPLIT SYSTEMS CONTENTS INDEX PART NUMBERS, OPTIONS, UNIT COMBINATIONS, DIMENSIONS & WEIGHTS 3 PERFORMANCE DATA & AIR FLOW 4 SOUND POWER AND SOUND PRESSURE LEVELS 5 ELECTRICAL DATA

More information

Air-Cooled Mini Chiller. Models: AMAC 040 A/AR AMAC 050 A/AR AMAC 058 A/AR AMAC 075 B/BR AMAC 100 B/BR AMAC 125 B/BR. Manual No: TMA-AMAC-1161

Air-Cooled Mini Chiller. Models: AMAC 040 A/AR AMAC 050 A/AR AMAC 058 A/AR AMAC 075 B/BR AMAC 100 B/BR AMAC 125 B/BR. Manual No: TMA-AMAC-1161 Models: AMAC 040 A/AR AMAC 050 A/AR AMAC 058 A/AR AMAC 075 B/BR AMAC 100 B/BR AMAC 125 B/BR Air-Cooled Mini Chiller Manual No: TMA-AMAC-1161 REGISTERED ISO 9002 CONTENTS PAGE 1. NOMENCLATURE SYSTEM...

More information

PORTABLE AIR CONDITIONER (LOCAL)

PORTABLE AIR CONDITIONER (LOCAL) EN PORTABLE AIR CONDITIONER (LOCAL) OPERATING INSTRUCTIONS Read the instructions carefully before operating the appliance or carrying out maintenance work. Observe all the safety instructions; failure

More information

Bosch Split-Type Ductless Air Conditioner / Heat Pump

Bosch Split-Type Ductless Air Conditioner / Heat Pump Bosch Split-Type Ductless Air Conditioner / Heat Pump Climate 5000 AA Series User Manual 2 Bosch Split Type Ductless Air Conditioner / Heat Pump User Manual Data subject to change 01.2017 Bosch Thermotechnology

More information

Owner s Manual SPLIT-TYPE ROOM AIR CONDITIONER

Owner s Manual SPLIT-TYPE ROOM AIR CONDITIONER Owner s Manual SPLIT-TYPE ROOM AIR CONDITIONER IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this manual for future reference.

More information

AIR-CONDITIONER SERVICE MANUAL

AIR-CONDITIONER SERVICE MANUAL FILE NO. A90-9608 SERVICE MANUAL AIR-CONDITIONER S SPLIT BUILT-IN DUCT TYPE RAV-362B-PE/ RAV-462B-PE/ SPLIT CEILING TYPE RAV-362C-PE/ RAV-462C-PE/ SPLIT CASSETTE TYPE RAV-362U-PE/ RAV-462U-PE/ PRINTED

More information

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC Revision E: MUZ-FH25VE- E4, ER4, ET3, MUZ- FH35VE- E3, ER3, ET3 and MUZ- FH50VE- E2, ER2, ET2 have been added. Please void OBH624 REVISED EDITION-D. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH624

More information

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL TECHNICAL DATA & SERVICE MANUAL OUTDOOR UNIT:. TRIAL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. 38.7107.102. 0.8180.611.02 09/2012 IMPORTANT! Please read before installation This air conditioning

More information

Owner s Manual. Fairwind Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER CS

Owner s Manual. Fairwind Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER CS SPLIT-TYPE ROOM AIR CONDITIONER Owner s Manual Fairwind Series All Model Numbers IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save

More information

Owner s Manual TABLE OF CONTENTS

Owner s Manual TABLE OF CONTENTS 40MBDQ Ducted Style Ductless System Sizes 18 to 48 Owner s Manual TABLE OF CONTENTS PAGE A NOTE ABOUT SAFETY... 2 GENERAL... 2 PARTS LIST... 3 DISPLAY PANELS... 4 FUNCTION BUTTONS... 5 REMOTE CONTROL...

More information

Service Manual. Room Air Conditioner Split Wall-Mounted Type. Applies to: HSG-09HRN1 HSG-12HRN1 HSG-18HRN1 HSG-24HRN1

Service Manual. Room Air Conditioner Split Wall-Mounted Type. Applies to: HSG-09HRN1 HSG-12HRN1 HSG-18HRN1 HSG-24HRN1 Service Manual Room Air Conditioner Split Wall-Mounted Type Applies to: HSG-09CRN1 HSG-12CRN1 HSG-18CRN1 HSG-24CRN1 HSG-09HRN1 HSG-12HRN1 HSG-18HRN1 HSG-24HRN1 NOTE: Please read this first before servicing

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING

More information

SERVICE MANUAL MUZ-LN25VG MUZ-LN35VG MUZ-LN50VG MUZ-LN60VG OUTDOOR UNIT. No. OBH767. Models HFC R32

SERVICE MANUAL MUZ-LN25VG MUZ-LN35VG MUZ-LN50VG MUZ-LN60VG OUTDOOR UNIT. No. OBH767. Models HFC R32 OUTDOOR UNIT SERVICE MANUAL HFC utilized R32. Models MUZ-LN25VG MUZ-LN35VG MUZ-LN50VG MUZ-LN60VG - E1, ER1, ET1 - E1, ER1, ET1 - E1, ER1, ET1 - E1, ER1, ET1 Indoor unit service manual MSZ-LN VGW/V/B/R

More information

Part 1 General Information... 1 Part 2 Indoor Units... 7 Part 3 Outdoor Units Part 4 Installation Part 5 Control...

Part 1 General Information... 1 Part 2 Indoor Units... 7 Part 3 Outdoor Units Part 4 Installation Part 5 Control... MCAC-UTSM-2008-11 Contents Part 1 General Information... 1 Part 2 Indoor Units... 7 Part 3 Outdoor Units... 88 Part 4 Installation... 127 Part 5 Control... 136 The specifications, designs, and information

More information

EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL WM150 OWNERS MANUAL Page 1 of 9 INTRODUCTION Designed for a wide range of applications, the WM150 is a rugged, industrial unit, which utilizes an

More information

Table of Contents SAFETY FIRST. Owner s Manual. Safety Precautions Unit Specifications and Features Manual Operation (Without Remote)...

Table of Contents SAFETY FIRST. Owner s Manual. Safety Precautions Unit Specifications and Features Manual Operation (Without Remote)... User Manual Table of Contents Owner s Manual 0 1 Safety Precautions...04 Unit Specifications and Features...06 SAFETY FIRST 2 Manual Operation (Without Remote)...11 3 Care and Maintenance...12 4 Troubleshooting...14

More information

PORTABLE AIR CONDITIONER

PORTABLE AIR CONDITIONER OWNER S MANUAL PORTABLE AIR CONDITIONER Model: CH-M09K6S F or proper operation, please read and keep this manual carefully. Designed by Cooper&Hunter International Corporation, Oregon, USA www.cooperandhunter.com

More information

TM: MCCKCM - W B. Fan Coil Units. Models: MWM-FW Series MCM-DW Series MCK-AW/BW Series MCC-CW Series MDB-BW Series

TM: MCCKCM - W B. Fan Coil Units. Models: MWM-FW Series MCM-DW Series MCK-AW/BW Series MCC-CW Series MDB-BW Series TM: MCCKCM - W - 2150B Fan Coil Units Models: MWM-FW Series MCM-DW Series MCK-AW/BW Series MCC-CW Series MDB-BW Series Contents Features... 1 Specifications... 3 Unit Selection Procedure... 11 Cooling

More information

PORTABLE AIR CONDITIONER (LOCAL)

PORTABLE AIR CONDITIONER (LOCAL) EN PORTABLE AIR CONDITIONER (LOCAL) OPERATING INSTRUCTIONS Read the instructions carefully before operating the appliance or carrying out maintenance work. Observe all the safety instructions; failure

More information

DAIKIN ROOM AIR CONDITIONER. Operation Manual. English. Deutsch. Français. Nederlands. Español. Italiano. Ελληνικά. Portugues. Русский.

DAIKIN ROOM AIR CONDITIONER. Operation Manual. English. Deutsch. Français. Nederlands. Español. Italiano. Ελληνικά. Portugues. Русский. DAIKIN ROOM AIR CONDITIONER Operation Manual FDXS25F2VEB FDXS60F2VEB FDXS35F2VEB FDXS50F2VEB English Deutsch Français Nederlands Español Italiano Ελληνικά Portugues Русский Türkçe CONTENTS READ BEFORE

More information

OPERATION MANUAL. Split series room air conditioners Multi system room air conditioners FDBQ25B7V1

OPERATION MANUAL. Split series room air conditioners Multi system room air conditioners FDBQ25B7V1 OPERATION MANUAL system room air conditioners 1 1 5 6 9 4 7 Pair Paar Paire Pair Par Singolo  ÁÔ Par Сплит 3 2 4 5 ÔÏÏ appleïfi Много 8 1 2a 2b 3a 3b 2a 2b 3a 3b NOTES system room air conditioners CONTENTS

More information

THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER. Instruction Manual. Model AMB-12H

THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER. Instruction Manual. Model AMB-12H THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER Instruction Manual Model AMB-12H PLEASE READ THIS INSTRUCTION MANUAL CAREFULLY BEFORE USING THIS UNIT. Table of Contents 1. SAFETY WARNINGS 2 2. CONSTRUCTION...

More information

FLOOR CONSOLE/ UNDER CEILING DUAL TYPE. ABT Series FUJITSU GENERAL LIMITED AIR CONDITIONER OPERATING MANUAL P/N

FLOOR CONSOLE/ UNDER CEILING DUAL TYPE. ABT Series FUJITSU GENERAL LIMITED AIR CONDITIONER OPERATING MANUAL P/N OPERATING MANUAL AIR CONDITIONER FLOOR CONSOLE/ UNDER CEILING DUAL TYPE ABT Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N9375756024 CONTENTS SAFETY PRECAUTIONS... 1 NAME OF PARTS...

More information

40LM Hz INSTALLATION, START-UP AND SERVICE INSTRUCTIONS CHILLED WATER FAN COIL UNIT

40LM Hz INSTALLATION, START-UP AND SERVICE INSTRUCTIONS CHILLED WATER FAN COIL UNIT Carrier International Sdn. Bhd. Malaysia INSTALLATION, START-UP AND SERVICE INSTRUCTIONS CHILLED WATER FAN COIL UNIT 40LM 120-200 50Hz CONTENTS: Physical Data & Dimension 1-3 Safety Considerations 4 Rigging

More information

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 128S5 FILE NO. SA 128S5 REFERENCE NO. SM700338

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 128S5 FILE NO. SA 128S5 REFERENCE NO. SM700338 TECHNICAL & SERVICE MANUAL SA 128S5 FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. Destination SA-128S5-A 1 851 004 09 General (50Hz) & Europe SA 128S5 REFERENCE NO. SM700338 IMPORTANT!

More information

Installation Manual PMV Kit RBM-PMV0363E RBM-PMV0903E

Installation Manual PMV Kit RBM-PMV0363E RBM-PMV0903E EB99802801-1 Installation Manual RBM-PMV0363E RBM-PMV0903E Installation Manual English OUTDOOR UNIT SIDE UPPER INDOOR UNIT SIDE Thank you very much for purchasing TOSHIBA Air conditioner. Please read this

More information

Owner s Manual CS

Owner s Manual CS Owner s Manual IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this manual for future reference. CS78421-548-754 Table of Contents

More information

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features. Spot Cooling Systems, Inc. 120 Century Drive Suite 00 Carrollton, TX 7006 00-6-776 Operation Manual SCT1B and SCT1B Warning! Improper installation, adjustment, alteration, service, or maintenance can cause

More information

Concealed Ducted Split Series R-407C MBH

Concealed Ducted Split Series R-407C MBH Concealed Ducted Split Series R-407C 4-60 MBH Ducted Split with Hermetic Compressor Tropical 50 Hz For more technical information please visit Table of Contents INTRODUCTION NOMENCLATURE UNIT RATING SUMMARY

More information

Service Manual & Installation Manual

Service Manual & Installation Manual GE Consumer & Industrial Appliances Service Manual & Installation Manual Split System Air Conditioner Model numbers: GE AIR C18 GE AIR C24 GE AIR C34 GE AIR C41 1 Introduction and Features Model Remarks

More information

OWNER S MANUAL VMH 09/12/18/24

OWNER S MANUAL VMH 09/12/18/24 OWNER S MANUAL VMH 09/12/18/24 Version C Inverter Single Zone Ductless Mini-Split Heat Pump Heat Controller, Inc. 1900 Wellworth Ave. Jackson, MI 49203 (517)787-2100 www.heatcontroller.com VMH Inverter

More information

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD TXV Horizontal Duct s EHD These instructions must be read and understood completely before attempting installation. It is important that the Blower and Duct System be properly sized to allow the system

More information

40KMC KMQ

40KMC KMQ 40KMC------301 40KMQ------301 OWNER S MANUAL Split system Global cassette indoor unit IR Remote Control Room Controller Zone Manager The unit can be used with infrared Remote Control, with the Carrier

More information

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. Models MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 Indoor unit service manual MSZ-DM VA Series (OBH750) CONTENTS 1. TECHNICAL CHANGES 2 2. PART NAMES

More information

TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA

TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA 0.8180.472.0 07/2005 Page 1. SPECIFICATIONS 3 1-1 Unit Specifications 3 1-2 Major Component Specifications 4 2. DIMENSIONAL DATA 6 2-1 Unit Dimensions 6 3. ELECTRICAL

More information

11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions. Model No. PE4-11R Soleus Air International

11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions. Model No. PE4-11R Soleus Air International 11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions Model No. PE4-11R-03 2006 Soleus Air International Thank you for choosing a Soleus Air Portable Air Conditioner.

More information

TECHNICAL & SERVICE MANUAL

TECHNICAL & SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CDITIERS TECHNICAL & SERVICE MANUAL No. OCH468 REVISED EDITI-A HFC utilized R4A June 2 [Model name] MXZ-8B48NA PAC-AKA5BC PAC-AKA3BC (Indispensable

More information

Installation Instructions

Installation Instructions 8GXM / 0GXM Multi---Split High---Wall Duct Free Split System 8GXM --- Size 18k, k, and 0k 0GXM --- Size 9k, 1k, and 18k Installation Instructions NOTE: Read the entire instruction manual before starting

More information