1 i-fav-08 FESH AI VENTIATIN INSTAATIN INSTUTINS HVA ontrols (F USE ITH 6 8 ) INTUTIN The i HVA ontrols Fresh Air Ventilation system is designed to improve residential indoor air quality. This is accomplished by introducing fresh, outside air through an intake damper controlled by a logic panel. The panel controls the amount of fresh air required each hour based on the ASHAE Ventilation and Indoor Air Quality Standard. INSTAATIN F INTAKE H, FESH AI INTAKE UT AN MTIZE It is recommended that the intake hood be an open metal type with a screen. The fresh air intake should be located away from dryer or furnace vents, driveways, trash containers, swimming pools and at a level above any expected snow accumulation. heck all local codes that might apply. epending on the FM requirement, an insulated, 6 or 8 diameter, rigid fresh air intake duct is recommended with a 6 or 8 diameter, 2-wire, motorized fresh air damper. The damper actuator should be power open / spring return closed. HVA ontrols TYPIA BASEMENT INSTAATIN SUPPY PENUM Furnace FESH AI INTAKE H INSUATE FESH AI UT MTIZE FESH AI VENTIATIN NT PANE EXTEI A ETUN AI PENUM

2 PANE VEVIE E1 E2 E3 E4 E5 PANE PE TAMS. FAN N PEN EXHAUST FAN MIN PEN MINUTES PE HU AUT SE Heating all Input Signal Fan Input from Thermostat Fan utput to HVA System HVA System Hot HVA System ommon A In A In A to amper A to amper PANE INSTAATIN To install the panel, remove the cover and slide the P board out of its base. Screw the base to a flat surface in a location that allows easy access for wiring. e-install the P board by carefully centering it over the base and snapping it into the track grooves. The panel receives its power from the equipment transformer. A separate A, 20VA transformer is required to power the fresh air damper. nly standard 18-gauge thermostat wire is required.! ANING Improper wiring to the HVA unit can cause damage to the equipment and/or the panel. isconnect electrical power before wiring the panel to the equipment.

3 TYPIA THEMSTAT IING IAGAMS SINGE STAGE HEAT/ THEMSTAT Y G E1 E2 E3 E4 E5 PANE FAN EXHAUST PE TAMS. N PEN FAN PEN MINUTES PE HU AUT SE Y G HVA UNIT INE VS TANSFME IE T MUTI- STAGE HEAT/ THEMSTAT 1 2 Y1 Y2 G E1 E2 E3 E4 E5 PANE FAN EXHAUST PE TAMS. N PEN FAN PEN MINUTES PE HU AUT SE 1 2 Y1 Y2 G HVA UNIT INE VS TANSFME IE T HEAT PUMP THEMSTAT 1 /B Y1 Y2 G E1 E2 E3 E4 E5 PANE FAN EXHAUST PE TAMS. N PEN FAN PEN MINUTES PE HU NTE: Y1 FM HEAT PUMP IES T N VS AUT SE 1 /B Y1 Y2 G IN UNIT INE VS TANSFME IE T

4 IING T PTINA EXHAUST FAN The panel can be wired to an optional exhaust fan using the terminals located on the panel. ire the terminals in series with the exhaust fan relay. hen the panel is in the AUT mode, the contacts close when the fresh air damper is opened. FAN EAY 1 2 INE EXHAUST FAN IING T PTINA VEIE SITH The panel can be wired to an optional damper override switch or timer using the terminals located on the panel. A dry contact closure across the terminals will open the fresh air damper and bring on the system fan. hen the panel is in the damper override mode, ventilation timing and all other override inputs are ignored. VEIE SITH TIME N.. IING T PTINA UT THEMSTAT AN/ HUMIISTAT The panel can be wired to an optional outdoor thermostat and/or humidistat using the terminals to prevent the fresh air damper from opening based on a temperature and/or humidity setting. The jumper located to the left of the terminals must be removed and the outdoor thermostat and/or humidistat wired so that the contacts are closed during normal operation. For outdoor thermostat installation: To lockout on high temperature, connect the Blue and ed wires to the terminals. (Black is not used.) To lockout on low temperature, connect the ed and Black wires to the terminals. (Blue is not used) EMVE JUMPE UT THEMSTAT HUMIISTAT N.. N..

5 VENTIATIN TIME QUIK EENE HAT The reference chart below is designed to provide FAV ventilation timer settings based on using 8 rigid straight duct with friction loss of 0.1 w.g. per 100 ft. This chart can be used for most applications. VENTIATIN TIME SETTING (MINUTES PE HU) NUMBE F BEMS NE T THEE FU FIVE HME SIZE (Ft²) < FMUA F SETTING THE VENTIATIN TIME The FAV Ventilation ontrol System is designed to simplify selecting the minimum ventilation cycle rate to meet ASHAE Standard by using a single dial to set the desired number of minutes per hour that ventilation will take place. The timer cycle rate is calculated as follows: (Home Area in Sq. Ft. x 0.03) + ((Number of Bedrooms + 1) x 7.5) = equired Airflow in FM (equired Airflow in FM x 60 Total Airflow of Fresh Air uct) x 60 = Ventilation Minutes Per Hour Example: Home Area = 2,500 Sq. Ft. with 4 bedrooms. (2,500 x 0.03 = 75) + ((4 + 1) x 7.5 =.50) = FM Total airflow of 8 rigid fresh air 0.1 w.c. = 220 FM x 60 = 13,200 ubic Feet Per Hour ( FM x 60 Minutes = 6,750) 6,600 13,200 x 60 =.68 Ventilation Minutes Per Hour The ventilation timer would be set for 31 Minutes HVA ontrols Indianapolis, IN For Technical Support all Toll Free: i

Wiring: All wiring should be conventional 18 gauge thermostat wire. Thermostats and zone dampers may be located up to 300 feet from the Z-300 panel.

Wiring: All wiring should be conventional 18 gauge thermostat wire. Thermostats and zone dampers may be located up to 300 feet from the Z-300 panel. THE EEN Z NE Z EE THE NE N Sequence of Operation: The reen Zone Z-300-HPS is a residential / light commercial zone control system that allows a single HVA unit to have up to three separate zones. Each

More information

Y8150 Fresh Air Ventilation System, W8150 Fresh Air Ventilation Control

Y8150 Fresh Air Ventilation System, W8150 Fresh Air Ventilation Control Y850 Fresh Air Ventilation System, 850 Fresh Air Ventilation ontrol FEATUES PODUT DATA Designed to help meet local ventilation codes and standards, including ASHAE 62.2-200 standard, Ventilation and Acceptable

More information

Y8150 Fresh Air Ventilation System, W8150 Fresh Air Ventilation Control

Y8150 Fresh Air Ventilation System, W8150 Fresh Air Ventilation Control Y850 Fresh Air Ventilation System, 850 Fresh Air Ventilation ontrol FEATUES PODUT DATA APPLIATION The Y850 Fresh Air Ventilation System, 850 Fresh Air Ventilation ontrol provide fresh air to a home. The

More information

Installation Instructions

Installation Instructions FAVXXR6C2100-A01 Vent Damper and Control Installation Instructions FAMILIARIZE YOURSELF WITH THE INSTALLATION INSTRUCTIONS BEFORE STARTING ATTENTION INSTALLER: This product must be installed by a qualified

More information

Zonex Systems Intelligent Fresh Air Ventilator Installation Instructions

Zonex Systems Intelligent Fresh Air Ventilator Installation Instructions Zonex ystems Installation Instructions Hotline (800) 228-2966 Visit Our Website www.zonexproducts.com The easy way to et Quotes Fast Part # IFAV introduction The Zonex ystems (PAT # IFAV) is a fresh air

More information

Model 8120 and 8126 Safety & Installation Instructions

Model 8120 and 8126 Safety & Installation Instructions Ventilation Controller Model 8120 and 8126 Safety & Installation Instructions FAMILIARIZE YOURSELF WITH THE INSTALLATION INSTRUCTIONS BEFORE STARTING DANGER ATTENTION INSTALLER: To prevent serious injury

More information

Fresh Air Ventilation Kit

Fresh Air Ventilation Kit Fresh Air Ventilation Kit io-fav-06 io-fav-08 The Fresh Air Ventilation system is designed to introduce fresh air into a home through an intake damper controlled by a micro-processor logic panel. The io-fav

More information

Installation Guide ProR221J, ProR212J, ProR321J and ProR312J

Installation Guide ProR221J, ProR212J, ProR321J and ProR312J ProZone I n t e l l i g e n t Z o n i n g Zones See table below. ompatible Equipment All panels operate with gas/electric systems, conventional heat pumps and dual fuel heat pumps. Equipment Selection

More information

ZONE 2 MOTOR SW2 OPEN M6 M4 M2 M1 CLOSED ZONE 1 MOTOR SW1 OPEN M6 M4 M2 M1 CLOSED 24V T'FORMER 2 CB1 SYSTEM B GHC R CONTROLS INC.

ZONE 2 MOTOR SW2 OPEN M6 M4 M2 M1 CLOSED ZONE 1 MOTOR SW1 OPEN M6 M4 M2 M1 CLOSED 24V T'FORMER 2 CB1 SYSTEM B GHC R CONTROLS INC. Z D7 Z D8 Z D D Z Z8 8 Z Z0 0 Z9 9 6 D D D0 D9 D D D6 D Z7 7 D D D9 D0 D D D D D0 D9 D7 D8 D6 D D D W xcellence Without ompromise NTLS IN THNIAL ULLTIN T 7 Models W STMS A & A Leave this bulletin on the

More information

Installer : Save these instructions for future use!

Installer : Save these instructions for future use! DESIPTIN Model Programmable Digital Thermostat Installer : Save these instructions for future use! AIUE T EAD AND INSTUTINS AEU EE INSTAATIN PEATIN UD DAMAE THIS NT AUSE PPET DAMAE. The is a Programmable

More information

Installation, Specification & Operation Guide HI TEMP LO TEMP SUPPLY I88. ecojay. SmartZone RESET GND HEAT PUMP GAS/ELECT RVS. VLV.

Installation, Specification & Operation Guide HI TEMP LO TEMP SUPPLY I88. ecojay. SmartZone RESET GND HEAT PUMP GAS/ELECT RVS. VLV. 00 ma SMAT LINK DAMPE DAMPE DAMPE or FA DAMPE POE -X & X Installation, Specification & Operation uide p. p. p. p. FULL US DIITAL DISPLA SPAE FUSE INLUDED QUIK SELESS TEMINALS O AS/ELETI THEMO EXLUSIVE

More information

NON-PROGRAMMABLE THERMOSTAT. The following Payne equipment is not compatible with the AC version (TSTATPPBAC01-B) of this

NON-PROGRAMMABLE THERMOSTAT. The following Payne equipment is not compatible with the AC version (TSTATPPBAC01-B) of this Installation Manual NN-PAMMABLE THEMSTAT TSTAT < < Fig. 1 Non-Programmable Thermostat NTE: ead the entire instruction manual before starting the installation. A98193 SAFET NSIDEATINS ead and follow manufacturer

More information

Product Instructions. Viega Programmable Heat/Cool Thermostat. Technical data

Product Instructions. Viega Programmable Heat/Cool Thermostat. Technical data Programmable Heat/ool Thermostat The programmable heat/cool thermostat is easy to install, easy to wire, and easy to program. It can be used for single stage heating and cooling applications, making it

More information

INSTALLATION AND MAINTENANCE INSTRUCTIONS. MHP4 Series. Self-Contained Heat Pump. Save these instructions for future reference

INSTALLATION AND MAINTENANCE INSTRUCTIONS. MHP4 Series. Self-Contained Heat Pump. Save these instructions for future reference INSTALLATIN AND MAINTENANE INSTUTINS MHP4 Series Self-ontained Heat Pump Save these instructions for future reference This is a safety alert symbol and should never be ignored. hen you see this symbol

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! WHITE-DGES 1F95W-71 7 Day Multi-stage Electronic Digital Thermostat with Programmable Fan INSTALLATIN INSTUTINS perator: Save these instructions for future use FAILUE T EAD AND FLLW ALL INSTUTINS AEFULLY

More information

Model CZ-4. Installation and Operating Instructions. FORM White-Rodgers by Permission B

Model CZ-4. Installation and Operating Instructions. FORM White-Rodgers by Permission B Model Z-4 Installation and Operating Instructions FOM 2045-2 1306 2013 White-odgers by Permission 37-6864B Z-4 ZONIN SSTM FATUS Purge Override Button Adjustable Second Stage Timer System Mode Indicator

More information

45 Commerce Ave., Unit #2 South Burlington, VT tel: fax:

45 Commerce Ave., Unit #2 South Burlington, VT tel: fax: SMAT ZONE TM VAV Electronic Diffusers SMAT ZONETM www.smartdiffuser.com SMAT ZONE SE-HC/M, Type LT, Lay-in, T-Bar, VAV Fully Modulating Diffuser Specifications APPLICATION: The Model SE-HC/M VAV Smart

More information

MAXIMUM UNIT AMPS MINIMUM WIRE SIZE

MAXIMUM UNIT AMPS MINIMUM WIRE SIZE WIIN DIAAMS FM 58MVP VAIALE-APAIT NDENSIN AS FUNAE (have attached arrier single stage A & arrier Humidifier) Table 5 Electrical Data UNIT SIZE VLTS HETZ PHASE PEATIN VLTAE ANE Maximum* Minimum* MAXIMUM

More information

CP-6 Installation and Operation Instructions 3 Heat / 2 Cool Heat Pump with Fossil Fuel option Auto Changeover - Cooling Priority or Majority Wins

CP-6 Installation and Operation Instructions 3 Heat / 2 Cool Heat Pump with Fossil Fuel option Auto Changeover - Cooling Priority or Majority Wins P-6 Installation and Operation Instructions 3 Heat / 2 ool Heat Pump with Fossil Fuel option Auto hangeover - ooling Priority or Majority Wins Sequence of Operation: Each zone damper is controlled by its

More information

Installation and Operating Instructions

Installation and Operating Instructions MASTZON ZONIN SSTM 4 Zones For use with the 24V Damper Motors Model MZS4 Installation and Operating Instructions ontrolling our omfort oom By oom MASTZON ZONIN SSTM FATUS Purge Override Button System Mode

More information

INSTALLATION MANUAL LISTED R-410A OUTDOOR SPLIT-SYSTEM HEAT PUMP MODELS: 18 SEER - YZH, HC8B, HL8B SERIES 2 TO 5 TONS TABLE OF CONTENTS

INSTALLATION MANUAL LISTED R-410A OUTDOOR SPLIT-SYSTEM HEAT PUMP MODELS: 18 SEER - YZH, HC8B, HL8B SERIES 2 TO 5 TONS TABLE OF CONTENTS INSTAATIN MANUA -40A UTD SPIT-SYSTEM HEAT PUMP MDES: 8 SEE - YZH, H8B, H8B SEIES T 5 TNS ISTED IS 900 ertified Quality Management System ENEA.............................................. SAFETY................................................

More information

FAST-STAT Black. Red. Gray. Purple. Orange. Orange. Black. Black. Compressor Stage 1 Heat Control. Transformer Transformer L1 L2

FAST-STAT Black. Red. Gray. Purple. Orange. Orange. Black. Black. Compressor Stage 1 Heat Control. Transformer Transformer L1 L2 FAST-STAT 7000 Nordic Electronics Ltd. 1-800-775-4750 Product Description The FAST-STAT Model 7000 provides 7-wire control from the thermostat to the furnace or fan-coil over a 4-wire cable. This includes,,,,,

More information

How to add or upgrade residential & commercial equipment without installing new cables. How to test & repair cables.

How to add or upgrade residential & commercial equipment without installing new cables. How to test & repair cables. Nordic Technology Ltd 1-800-775-4750 www.fast-stat.com This is the printer-friendly edition. o to www.fast-stat.com to download and print additional copies HVA iring Solutions How to add or upgrade residential

More information

Safety & Installation Instructions

Safety & Installation Instructions Model 8620 Thermostat with Event-Based Air leaning and Humidity or Ventilation ontrol Safety & Installation Instructions READ AND SAVE THESE INSTRUTIS Table of contents Installation Installation location

More information

TB-226 ZONE 3 MOTOR M6 M4 M2 M1 ZONE 2 MOTOR M6 M4 M2 M1 MOTOR M6 M4 M2 M1 24 VAC T'FORMER SYSTEM W2/E W1/B O RH RC RC/RH LINK.

TB-226 ZONE 3 MOTOR M6 M4 M2 M1 ZONE 2 MOTOR M6 M4 M2 M1 MOTOR M6 M4 M2 M1 24 VAC T'FORMER SYSTEM W2/E W1/B O RH RC RC/RH LINK. The New NM300 panel provides intelligent control of Heat Pump or onventional forced air zoning systems at a maximum of three zones using motorized dampers and practically any off-the-shelf thermostat.

More information

Model 1750A/ 1770A Dehumidifier Installation Instructions

Model 1750A/ 1770A Dehumidifier Installation Instructions Model 1750A/ 1770A Dehumidifier Installation Instructions Safety Instructions WARNING 1. Improper installation may cause property damage or injury. Installation, service, and maintenance must be performed

More information

ZONE 3 MOTOR M6 M4 M2 M1 ZONE 2 MOTOR M6 M4 M2 M1 MOTOR M6 M4 M2 M1 24 VAC T'FORMER SYSTEM W2/E W1/B O RH RC RC/RH LINK.

ZONE 3 MOTOR M6 M4 M2 M1 ZONE 2 MOTOR M6 M4 M2 M1 MOTOR M6 M4 M2 M1 24 VAC T'FORMER SYSTEM W2/E W1/B O RH RC RC/RH LINK. The New NM300 panel provides intelligent control of Heat Pump or onventional forced air zoning systems at a maximum of three zones using motorized dampers and practically any off-the-shelf thermostat.

More information

INSTALLATION ACCESSORIES

INSTALLATION ACCESSORIES INSTALLATIN CESSIES oom Thermostats The heem Thermostat line includes temperature control solutions for all heem residential and commercial HV equipment Service Valves The service valve kits available

More information

Heat or Energy Recovery Ventilation System

Heat or Energy Recovery Ventilation System INSTALLATION MANUAL Heat or Energy Recovery Ventilation System MODELS: FC80 HRV & FC80 ERV This device MUST be installed by a qualified agency in accordance with the manufacturer's installation instructions.

More information

SAFETY AND INSTALLATION MANUAL MODEL 8100

SAFETY AND INSTALLATION MANUAL MODEL 8100 SAFETY AND INSTALLATION MANUAL ENERGY RECOVERY VENTILATORS MODEL 8100 Provides year-round fresh air Recovers 77% of the apparent heating or cooling energy from the exhausted air See Warnings Page 3 Table

More information

READ AND SAVE THESE INSTALLATION INSTRUCTIONS

READ AND SAVE THESE INSTALLATION INSTRUCTIONS Nomenclature: D F I 0 0 H : Open coil element T: Tubular element F: Finned tubular element I: Slip in type F: Flange type 0: No screen left of the heater 1: Screen left of the heater 0: No screen right

More information

Put the V back in HVAC

Put the V back in HVAC Put the V back in HVAC V is for Ventilation A system or means of providing fresh air. Webster New Collegiate Dictionary Benjamin Franklin so unwholesome as air in a closed room that has been often breathed

More information

Installation Instructions MODEL 8870

Installation Instructions MODEL 8870 Installation Instructions MDEL 8870 These instructions are for connecting the Thermostat to the HVA equipment. To connect communication features, please reference the ommunicating Thermostat System Installation

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! WHITE-DGES 1F94-80 Multi-stage Electronic Digital Thermostat INSTAATIN INSTUTINS perator: Save these instructions for future use FAIUE T EAD AND FW A INSTUTINS AEFUY EFE INSTAING PEATING THIS NT UD AUSE

More information

VENTILATORS VH30100 COMPACT HEAT RECOVERY VENTILATOR VE30100 COMPACT ENERGY RECOVERY VENTILATOR. Installation and Operation Manual.

VENTILATORS VH30100 COMPACT HEAT RECOVERY VENTILATOR VE30100 COMPACT ENERGY RECOVERY VENTILATOR. Installation and Operation Manual. VENTILATORS MODELS: VH30100 30-100 CFM HRV VE30100 30-100 CFM ERV Features Three operating modes (Intermittent, Continuous and High) 100% variable speed Quick-connect duct collar system Proportional defrost

More information

Installation Instructions WARNING WARNING. Variable Speed High Efficiency Blower Kit for Gas Furnace Applications 3. INSTALLATION

Installation Instructions WARNING WARNING. Variable Speed High Efficiency Blower Kit for Gas Furnace Applications 3. INSTALLATION Installation Instructions Variable Speed High Efficiency Blower Kit for Gas Furnace Applications ANING To avoid the risk of electrical shock, personal injury, or death, disconnect electrical power before

More information

Y8196A (T8196A Thermostat/ Q682A Subbase) Heating/Cooling New Construction Thermostat/Subbase Package Installation Instructions

Y8196A (T8196A Thermostat/ Q682A Subbase) Heating/Cooling New Construction Thermostat/Subbase Package Installation Instructions M3375 M3375 89A (T89A Thermostat/ Q8A Subbase) Heating/Cooling New Construction Thermostat/Subbase Package Installation Instructions Preparation Check thermostat and subbase suitability for the heating,

More information

Thermidistat Control Installation, Start-Up, and Operating Instructions

Thermidistat Control Installation, Start-Up, and Operating Instructions Visit www.carrier.com Thermidistat ontrol Installation, Start-Up, and perating Instructions NTE: ead the entire instruction manual before starting the installation. INDEX Page SAFET NSIDEATINS...1 INTDUTIN...1

More information

Desiccant Dehumidifier

Desiccant Dehumidifier Since the 1950s Desiccant Dehumidifier Dry Spaces With NO Added Heat BMIL Technologies, LLC 4915 Arendell St., #313 Morehead City, NC 28557 PH 252-727-0994 FAX 252-727-0996 WWW.BMIL.COM Product Description

More information

INSTALLATION MANUAL LISTED R-410A OUTDOOR SPLIT-SYSTEM HEAT PUMP MODELS: 15 SEER - YZE / HC5B / HL5B SERIES 2 TO 5 TONS TABLE OF CONTENTS

INSTALLATION MANUAL LISTED R-410A OUTDOOR SPLIT-SYSTEM HEAT PUMP MODELS: 15 SEER - YZE / HC5B / HL5B SERIES 2 TO 5 TONS TABLE OF CONTENTS INSTAATIN MANUA -40A UTD SPIT-SYSTEM HEAT PUMP MDES: 5 SEE - YZE / H5B / H5B SEIES T 5 TNS ISTED IS 900 ertified Quality Management System ENEA.............................................. SAFETY................................................

More information

ACCESSORY KIT INSTALLATION MANUAL

ACCESSORY KIT INSTALLATION MANUAL AESSY KIT INSTALLATIN MANUAL MMUNIATIN INTEFAE NTL FIELD KIT - ET FIT APPLIATINS F USE ITH MDELS: All Models (Non-ommunicating Units) ENEAL INFMATIN To be used with non-communicating indoor units and some

More information

LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES

LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES INSTALLATIN MANUAL UTD SPLIT-SYSTEM HEAT PUMP MDELS: 16 SEE - YZF, H6B, HL6B SEIES 18 SEE - YZH, H8B, HL8B SEIES 2 T 5 TNS ENEAL..............................................1 SAFETY................................................1

More information

FEATURES AND BENEFITS

FEATURES AND BENEFITS FEATURES AND BENEFITS Product Features and Benefits Full Product Line Offering Feature All models are 80% thermally efficient Blower performance up to 3.0 W.C. DX or chilled water section with factory

More information

HEALTHY HOME SYSTEM CONTROL Plus Model: HHSC+

HEALTHY HOME SYSTEM CONTROL Plus Model: HHSC+ HEALTHY HOME SYSTEM CONTROL Plus Model: HHSC+ The Field Controls Healthy Home System Controller Plus (HHSC+) is designed to work in conjunction with the forced air HVAC system to periodically introduce

More information

HEAT COOL HEAT PUMP. Installation Instructions TSTATCCPS101 TSTATBBPS101 P Digital Thermostat 6:03

HEAT COOL HEAT PUMP. Installation Instructions TSTATCCPS101 TSTATBBPS101 P Digital Thermostat 6:03 Installation Instructions TSTATPS101 TSTATBBPS101 P374-1000 Digital Thermostat NTE: ead the entire instruciton manual before starting the installation. 6:03 68 Am AUT 70 L HEAT 67 o o HEAT L & HEAT PUMP

More information

INDOOR AIR QUALITY CCWH Complete Comfort Whole-Home Dehumidifier ENGINEERING DATA. Nominal Capacity - 65 to 135 pints per day CCWH - 090

INDOOR AIR QUALITY CCWH Complete Comfort Whole-Home Dehumidifier ENGINEERING DATA. Nominal Capacity - 65 to 135 pints per day CCWH - 090 ENGINEERING DATA INDOOR AIR QUALITY CCWH Complete Comfort Whole-Home Dehumidifier Bulletin No. CCWH (08/2011) CCWH-065 CCWH-090 CCWH-135 ENERGY STAR Rating for CCWH-065 Model Only Nominal Capacity - 65

More information

asy Single Day up to 2-heat & 2-cool Stat

asy Single Day up to 2-heat & 2-cool Stat asy Stat Single Day PAMMAB residential THMSTAT TSTATZ world s easiest PAMMAB THMSTAT up to 2-heat & 2-cool utdoor Sensor eady - ompatible with the optional wired, or wireless utdoor Sensor ne for All -

More information

Installation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. RXID-AW90A Whole House Dehumidifier

Installation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. RXID-AW90A Whole House Dehumidifier RXID-AW90A Whole House Dehumidifier with fresh air ventilation Installation Guide Dehumidification Fresh Air Ventilation Compact Size Energy Efficient The whole house dehumidifier integrates highcapacity

More information

Installation Instructions P/N

Installation Instructions P/N IM2 eplacement Kit For FK4A ancels: IIK FK4A-2-2 IIK FK4A-2-3 6-1 Installation Instructions P/N 32981-752 NTE: ead the entire instruction manual before starting the installation. SAFETY NSIDEATINS Improper

More information

MD6-ES24VK. Installation, Operation, and Maintenance Manual

MD6-ES24VK. Installation, Operation, and Maintenance Manual MD6-ES24VK Installation, Operation, and Maintenance Manual EAD AND SAVE THESE INSTUTIONS The purpose of this manual is to aid in the proper installation and operation of fans manufactured by S&P. These

More information

Installation and Operating Instructions

Installation and Operating Instructions Visit www.carrier.com Non-Programmable Thermostat TSTATN(A,HP,2S)01- Installation and perating Instructions NTE: ead the entire instruction manual before starting the installation. This symbol indicates

More information

Wiring Instructions. High-Capacity Steam Humidifiers

Wiring Instructions. High-Capacity Steam Humidifiers Wiring Instructions for High-Capacity Steam Humidifiers Including Instructions for Compensating Humidistat and Safety Control Shutoff CONTRACTOR: Read these instructions before installing or servicing

More information

INSTALLATION GUIDE RESIDENTIAL USE ONLY. Greentek Models SS 3.80 FSD HRV (Item No ) SS 3.80 FSD ERV (Item No )

INSTALLATION GUIDE RESIDENTIAL USE ONLY. Greentek Models SS 3.80 FSD HRV (Item No ) SS 3.80 FSD ERV (Item No ) INSTALLATION UIDE ESIDENTIAL USE ONLY reentek Models SS 3.80 FSD HV (Item No. 102208) SS 3.80 FSD EV (Item No. 102210) Imperial Models SS 3.80 FSD HV (Item No. 102257) SS 3.80 FSD EV (Item No. 102259)

More information

IF78 CAUTION CONTENTS YOUR THERMOSTAT REPLACES PREPARATIONS. Installation Instructions for. Heating & Air Conditioning. Non-Programmable Thermostat

IF78 CAUTION CONTENTS YOUR THERMOSTAT REPLACES PREPARATIONS. Installation Instructions for. Heating & Air Conditioning. Non-Programmable Thermostat CNTENTS Installation Instructions for Heating & Air Conditioning IF78 n-programmable Thermostat Preparations... 1 Thermostat Details... 1 Removing ld Thermostat... 1 Mounting and iring... 2 Check Thermostat

More information

Commercial Thermostat

Commercial Thermostat ommercial Thermostat Submittal Data *204* 204 ev.: November 18, 2016 limatemaster works continually to improve its products. As a result, the design and specifications of each product at the time of order

More information

Mastertrol Automatic Balancing System (MABS ) EZ Zone (EZ-2 and EZ-4) Control Panels

Mastertrol Automatic Balancing System (MABS ) EZ Zone (EZ-2 and EZ-4) Control Panels Mastertrol Automatic Balancing System (MABS ) Z Zone (Z-2 and Z-4) ontrol Panels FATUS PDUT DATA APPLIATIN The MABS Z-2 and Z-4 are microprocessor-based forced air zone control panels that provide automatic

More information

INSTALLATION GUIDE. Horizontal series. HRV MODEL 8160 and MODEL 8220 ERV MODEL 3160 and MODEL 3220

INSTALLATION GUIDE. Horizontal series. HRV MODEL 8160 and MODEL 8220 ERV MODEL 3160 and MODEL 3220 INSTALLATION GUIDE Horizontal series HRV MODEL 8160 and MODEL 8220 ERV MODEL 3160 and MODEL 3220 INSTALLATION GUIDE Peace of Mind All GeneralAire products are backed by the best limited warranty in the

More information

1 PREPARATIONS 2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT. 1E78 Non-Programmable Thermostat CONTENTS

1 PREPARATIONS 2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT. 1E78 Non-Programmable Thermostat CONTENTS CNTENTS Installation Instructions for Heating & Air Conditioning 1E78 Non-Programmable Thermostat Preparations... 1 Thermostat Details... 1 Removing ld Thermostat... 1 Mounting and iring... 2 Check Thermostat

More information

Installation Instructions

Installation Instructions ERVCRLHB Energy Recovery Ventilator HRVCRLHB Heat Recovery Ventilator Installation Instructions ERV/HRV Unit A0560 INTRODUCTION The Energy/Heat Recovery Ventilator (ERV/HRV) is used to exchange indoor

More information

March 2003 AB0303. Accessories Book. Fantech I Your Ventilation Solutions Company

March 2003 AB0303. Accessories Book. Fantech I Your Ventilation Solutions Company March 200 00 ccessories ook Fantech I Your Ventilation Solutions ompany Supply/xhaust Fans ombination xhaust Grill and Light VL Vent light combination. Smallscale grill with 0 watt halogen light (MR1 bulb

More information

INSTALLATION GUIDE VB0180 VB0148

INSTALLATION GUIDE VB0180 VB0148 INSTALLATION GUIDE VENMAR AVS VÄNEE VB0179 VB0180 VB0177 VB0178 Kubix ERV (side ports) Model no. 44113 Kubix ERV (top ports) Model no. 44112 Vïgor ERV (side ports) Model no. 44213 Vïgor ERV (top ports)

More information

August 2004 AB0804. Accessories Book. Fantech I Your Ventilation Solutions Company

August 2004 AB0804. Accessories Book. Fantech I Your Ventilation Solutions Company ugust 200 00 ccessories ook Fantech I Your Ventilation Solutions ompany Supply/xhaust Fans ombination xhaust Grill and Light VL Vent light combination. Smallscale grill with 0 watt halogen light (MR1 bulb

More information

York 25-Ton VAV Rooftop Unit

York 25-Ton VAV Rooftop Unit HVAC PRO for Windows User s Manual 637.5 OEM Section Technical Bulletin Issue Date 0996 York 25-Ton VAV Rooftop Unit Introduction Page 3 Overview *3 Configuration 5 Sequence of Operation 7 Modes of Operation

More information

Premier 2-Zone Controller model Installer Guide

Premier 2-Zone Controller model Installer Guide Premier 2-Zone ontroller model 140202 Installer uide ONTENTS 1 Specifications 4 onfiguration 2 Suitable Mounting Locations 5 System heckout 3 Wiring Diagrams 6 Operation Warning Read all of the instructions

More information

Installation Guide. MAX Series. 69-MAX-Install Setting a new standard for energy efficient, clean air homes

Installation Guide. MAX Series. 69-MAX-Install Setting a new standard for energy efficient, clean air homes MAX Series Installation Guide Setting a new standard for energy efficient, clean air homes 69-MAX-Install 012616 511 McCormick Blvd London, Ontario Canada N5W 4C8 519.457.1904 General Info / Tech Support:

More information

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS TTALINE 1c.eps gold-1.pdf INSTALLATI AND PEATIN INSTUTIS esidential Programmable Thermostats Part No. P274-1100, 1200, 1300 TENTS Page SAFET SIDEATIS...................... 1 ENEAL........................................

More information

S1-CVD090T01 / S1-CVD135T01 Central Ventilating Dehumidifier Installation Instructions. Johnson Controls Unitary Products WARNING CAUTION

S1-CVD090T01 / S1-CVD135T01 Central Ventilating Dehumidifier Installation Instructions. Johnson Controls Unitary Products WARNING CAUTION Johnson ontrols Unitary Products S1-VD090T01 / S1-VD135T01 entral Ventilating Dehumidifier Installation Instructions Humidity ontrol Inlet Filter Access Filter Access Outlet Service Access Port Wiring

More information

Light Commercial Heat Recovery Ventilators Installation, Operation and Service Instructions

Light Commercial Heat Recovery Ventilators Installation, Operation and Service Instructions Light ommercial Heat ecovery Ventilators Installation, Operation and Service Instructions VB000 VB000 00 cfm 00 cfm VB000 00 cfm 0/00 05 ontents Safety onsiderations................................................

More information

Install guide Customer Support: or Visit our website OFF FAN HEAT COOL AUTO ON

Install guide Customer Support: or Visit our website OFF FAN HEAT COOL AUTO ON Install guide 8022 HEAT OOL AUTO ON ustomer Suppt: 888-515-2585 Visit our website www.ritetemp.biz Install guide 8022 aution Tools To avoid electrical shock and to prevent damage to the furnace, air conditioner,

More information

Heat Recovery Air Handling Units

Heat Recovery Air Handling Units Heat Recovery ir Handling Units OMEKT Heat recovery air handling Units OMEKT 1 KOMFOVENT OMEKT ir Handling Units Komfovent ir Handling units are made to create healthy indoor climate and ensure efficient

More information

Model 1730A Compact Dehumidifier Installation Instructions

Model 1730A Compact Dehumidifier Installation Instructions Model 1730A ompact Dehumidifier Installation Instructions WANING 1. 120 volts may cause serious injury from electric shock. Disconnect electrical power before starting installation. Leave power disconnected

More information

Installation, Safety & Maintenance Manual Model 1750A/1770A

Installation, Safety & Maintenance Manual Model 1750A/1770A Central Dehumidifier Filter Access Humidity Control Inlet Outlet Service Access Port Filter Access Wiring Access Wire Routing Port Drain On/Off Switch Installation, Safety & Maintenance Manual Model 1750A/1770A

More information

INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS

INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS INSTALLATION GUIDE VB0190 Model ERV70S (side ports) VB0192 Model ERV70T (top ports) VB0191 Model HRV70SE* (side ports) VB0193 Model HRV70TE* (top ports) * These products earned the ENERGY STAR by meeting

More information

ICM 275. Replacement Description

ICM 275. Replacement Description IM 275 Fan ontrol enter Replacement Description The IM275 Gas Furnace ontrol enter is a new generation control for the replacement market. The IM275 Gas Furnace ontrol enter is designed to function similarly

More information

OPERATIONS & MAINTENANCE MANUAL RESIDENTIAL HEAT & ENERGY RECOVERY VENTILATORS TO BE COMPLETED BY CONTRACTOR AFTER INSTALLATION

OPERATIONS & MAINTENANCE MANUAL RESIDENTIAL HEAT & ENERGY RECOVERY VENTILATORS TO BE COMPLETED BY CONTRACTOR AFTER INSTALLATION Meets Standards: C22.2 no 113 and UL 1812 OPERATIONS & MAINTENANCE MANUAL RESIDENTIAL HEAT & ENERGY RECOVERY VENTILATORS FOR MODELS: H/E95 H/E110 H/E150 H/E190 H/E240 TO BE COMPLETED BY CONTRACTOR AFTER

More information

H1008A,D Automatic Humidity Controls

H1008A,D Automatic Humidity Controls H00A,D Automatic Humidity Controls FEATURES PRODUCT DATA The H00A,D provides automatic control for by-pass flow-through, powered flow-through, steam and drum humidifiers in central heating systems. The

More information

T8000C Programmable Thermostat

T8000C Programmable Thermostat T8000C Programmable Thermostat APPLICATIN The T8000C Thermostat provides single-stage, programmable temperature control for 24 Vac heating-cooling systems with manual changeover from heat to cool. Heating

More information

Standard Programmable Thermostat Homeowner s Guide / Installation, Start-Up, and Operating Instructions

Standard Programmable Thermostat Homeowner s Guide / Installation, Start-Up, and Operating Instructions Standard Programmable Thermostat Homeowner s uide / Installation, Start-Up, and perating Instructions Visit www.carrier.com Homeowner s uide < < Fig. 1 Standard Programmable Thermostat A99068 Programming

More information

ACCESSORY KIT INSTALLATION MANUAL ADD-ON FOSSIL FUEL CONTROL PANEL S1-2AC FOR USE WITH MODELS: FRHS, E*FD, E*RE OR E*BE HEAT PUMPS

ACCESSORY KIT INSTALLATION MANUAL ADD-ON FOSSIL FUEL CONTROL PANEL S1-2AC FOR USE WITH MODELS: FRHS, E*FD, E*RE OR E*BE HEAT PUMPS ACCESS KIT INSTALLATIN MANUAL ADD-N FSSIL FUEL CNTL PANEL S1-2AC02700701 F USE ITH MDELS: FHS, E*FD, E*E E*BE HEAT PUMPS GENEAL This product must be installed in strict compliance with the enclosed installation

More information

Novofit 2.0 (Part no )

Novofit 2.0 (Part no ) INSTALLER MANUAL VENTILATION SYSTEMS FOR RESIDENTIAL USE ONLY VB0157 Novofit 1.5* (Part no. 43121) Novofit 2.0 (Part no. 45121) *This product earned the ENERGY STAR by meeting strict energy efficiency

More information

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini... Contents How to choose Recovery Ventilation type?............................................3 How do HRV, ERV and TRV Systems work?............................................4 Types of installations..............................................................5

More information

Honeywell Easy Ventilation Wiring

Honeywell Easy Ventilation Wiring Honeywell Easy Ventilation Wiring ADDENDUM Fresh Air Demand: ASHRAE 2010/2013 Lockouts: Wi-Fi (Internet present) 1. Honeywell TH6320WF (T6 Wi-Fi) Ventilation capable thermostat w/ lockouts. 2. Honeywell

More information

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions ON/OFF button used to turn the ventilator on and off Up/Down buttons used to change humidity or vent time setting

More information

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions ON/OFF button used to turn the ventilator on and off Up/Down buttons used to change humidity or vent time setting

More information

VENTILATION SYSTEMS. Model Numbers HRV-150 HRV-210 ERV-150 ERV-210

VENTILATION SYSTEMS. Model Numbers HRV-150 HRV-210 ERV-150 ERV-210 Installer Manual VB0065 VENTILATION SYSTEMS Model Numbers HRV-150 HRV-210 ERV-150 ERV-210 06787-04/12/22 Table of Contents 1.0 SERVICE...4 1.1 3-D Drawing...4 1.2 Parts Ordering Chart...5 1.3 Technical

More information

INSTALLATION MANUAL. Need Help? This manual covers the following models: T905. Power Type. Thermostat Applications Guide. Page.

INSTALLATION MANUAL. Need Help? This manual covers the following models: T905. Power Type. Thermostat Applications Guide. Page. INSTALLATION MANUAL This manual covers the following models: T905 Thermostat Applications uide Description as or Oil Heat Electric Furnace Heat Pump (No Aux. or Emergency Heat) Heat Pump (with Aux. or

More information

CEPL WeatherMaker Two-Zone Installation and Start-Up Instructions

CEPL WeatherMaker Two-Zone Installation and Start-Up Instructions P WeatherMaker Two-Zone Installation and Start-Up Instructions NT: ead the entire instruction manual before starting the installation. TA F NTNTS PA Safety onsiderations...1 Installation onsiderations...1

More information

Installation Instructions

Installation Instructions HRVXXLHB Heat Recovery Ventilator Installation Instructions HRVXXLHB Unit These products earned the ENERGY STAR by meeting strict energy efficiey guidelines set by Natural Resources Canada and the US EPA.

More information

Installation Instructions

Installation Instructions HRVCRSVU57 Heat Recovery Ventilator Installation Instructions HRVCRSVU57 A89 NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper installation, adjustment,

More information

S1-CD065T01 Central Dehumidifier Installation Instructions. Johnson Controls Unitary Products WARNING CAUTION SPECIFICATIONS LOCATION CONSIDERATIONS

S1-CD065T01 Central Dehumidifier Installation Instructions. Johnson Controls Unitary Products WARNING CAUTION SPECIFICATIONS LOCATION CONSIDERATIONS Johnson ontrols Unitary Products S1-D065T01 entral Dehumidifier Installation Instructions WANING 1. 120 volts may cause serious injury from electric shock. Disconnect electrical power before starting installation.

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! WHITE-DGES 1F92W-71 Multi-stage/ Pump Electronic Digital Thermostat INSTAATIN INSTUTINS perator: Save these instructions for future use FAIUE T EAD AND FW A INSTUTINS AEFUY EFE INSTAING PEATING THIS NT

More information

TECHNICAL GUIDE. Acclimate MODELS: FL9S GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW SINGLE STAGE FURNACES 92% AFUE

TECHNICAL GUIDE. Acclimate MODELS: FL9S GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW SINGLE STAGE FURNACES 92% AFUE TEHNIAL GUIDE Acclimate MODELS: FL9S GAS-FIRED ONDENSING / HIGH EFFIIENY UPFLOW SINGLE STAGE FURNAES 92% AFUE NATURAL GAS 40-135 MBH INPUT EFFIIENY RATING ERTIFIED ISO 9001 ertified Quality Management

More information

Installation Instructions

Installation Instructions CCLHA Energy Recovery Ventilator Sizes 50 and 200 Installation Instructions TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... INTRODUCTION... INSTALLATION CONSIDERATIONS... COMPONENT DESCRIPTIONS... 2 UNIT

More information

Installation Instructions

Installation Instructions FPMANU & FPMBNU UNASED HIZNTAL FAN IL UNITS Installation Instructions NTE: ead the entire instruction manual before starting installation. TABLE F NTENTS PAE SAFET NSIDEATINS... 1 INTDUTIN... 1 INSTALLATIN...

More information

PART NO. COMBUSTION AIR CAP

PART NO. COMBUSTION AIR CAP ACCESSORIES FOR SPACE-RAY TUBE HEATERS VENT CAP --- Sidewall or Roof Unique design prevents back drafts and assists in drawing off and exhausting the products of combustion regardless of wind direction

More information

INSTALLATION MANUAL MODELS ERV CONSTRUCTO 1.5 QUATTRO ERV CONSTRUCTO 2.0 QUATTRO READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL USE ONLY

INSTALLATION MANUAL MODELS ERV CONSTRUCTO 1.5 QUATTRO ERV CONSTRUCTO 2.0 QUATTRO READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL USE ONLY INSTALLATION MANUAL VB000 MODELS ERV CONSTRUCTO.5 QUATTRO ERV CONSTRUCTO 2.0 QUATTRO FOR RESIDENTIAL USE ONLY READ AND SAVE THESE INSTRUCTIONS 0798 rev. A About this Manual This manual uses the following

More information

INSTALLER AND USER MANUAL VENTILATION SYSTEM

INSTALLER AND USER MANUAL VENTILATION SYSTEM INSTALLER AND USER MANUAL VENTILATION SYSTEM VB0230 HRV Solo 2.4 & ERV Quattro 2.4 READ AND SAVE THESE INSTRUCTIONS INSTALLER: LEAVE THIS MANUAL TO THE HOMEOWNER 22068 rev. 01 ABOUT THIS MANUAL This manual

More information

Install guide 8010 ENGLISH. Customer Support: or Visit our webiste Made in China

Install guide 8010 ENGLISH. Customer Support: or Visit our webiste  Made in China Install guide 8010 ENLISH ustomer Suppt: 888-515-2585 Visit our webiste www.ritetemp-thermostats.com Made in hina 1-402-033 Install guide 8010 aution Tools 1 Location To avoid electrical shock and to prevent

More information

INSTALLATION GUIDE FOR AVS HRV EKO 1.5, AVS CONSTRUCTO 1.5V, HRV 90H-V ECM AND 90H-V UNITS

INSTALLATION GUIDE FOR AVS HRV EKO 1.5, AVS CONSTRUCTO 1.5V, HRV 90H-V ECM AND 90H-V UNITS INSTALLATION GUIDE FOR AVS HRV EKO.5, AVS CONSTRUCTO.5V, HRV 90H-V ECM AND 90H-V UNITS THIS UNIT HAS A SPECIAL START-UP PROCEDURE, REFER TO PAGE. V09 THIS UNIT HAS A SPECIAL START-UP PROCEDURE, REFER TO

More information

INSTALLATION MANUAL LISTED

INSTALLATION MANUAL LISTED INSTALLATIN MANUAL UTD SPLIT-SYSTEM HEAT PUMP MDELS: 3 SEE - YZB SEIES 5 SEE - YZE, H5B, HL5B SEIES 6 SEE - YZF, H6B, HL6B SEIES 8 SEE - YZH, H8B, HL8B SEIES T 5 TNS LISTED ENEAL..............................................

More information