Gas Safety. Syllabus. For. Gas Appliance Service. Certificate of Qualification Examination. (Formerly Class C)
|
|
- Felicia Sutton
- 5 years ago
- Views:
Transcription
1 Gas Safety Syllabus For Gas Appliance Service Certificate of Qualification Examination (Formerly Class C)
2 1. Prerequisites to obtain a gas appliance service certificate of qualification An applicant for a gas appliance service certificate of qualification must have successfully completed a course in gas appliance service training acceptable to a provincial safety manager. 2. Scope of work that may be performed by an individual holding a gas appliance service certificate of qualification A gas appliance service certificate of qualification entitles the holder to perform the servicing of the following gas systems while employed by a licensed gas contractor or under an appropriate permit: a. gas appliances installed for residential use, or b. light commercial appliances up to an input of 82 kw (280,000 Btu). The gas appliance service certificate of qualification is intended for the servicing (maintenance) and repair of gas fired residential and light commercial appliances. It does not allow or include the following: a. the installation of new or replacement appliances, b. the installation of gas piping, and c. the repair or installation of venting. An appliance service technician certification is not a prerequisite to a Class B gas fitter certification. Individuals who acquire this certification and wish to obtain a class B gas fitter certification must also complete a recognized apprenticeship program. 3. Subject Areas of Study Safety Standards Act, Safety Standards General Regulation and Gas Safety Regulation. Percentage (%) on exam 3.1 Regulations 5% Appliance Service Technician Qualification Permissions Appliance Service Technician Qualification Responsibilities Contractor Licenses Safety Manager and Safety Officer powers Additional provincial technical requirements Appliance certification 3.2 Gas Properties 5% Contents (Natural & Propane) Specific Gravity
3 3.2.3 Flammable Limits Ignition Temperature Flame Speed Toxicity State (Liquid and Gaseous) 3.3 Combustion 10% Perfect Combustion Products of Combustion and Volumes Air Required Carbon Monoxide Air (Combustion, Excess and Dilution) Flue Gas Analyzers and Analysis Combustion Efficiency 3.4 Regulators 13% Principle of Operation Types-Service, Line Pressure, Appliance Low Pressure Systems Two Stage Propane regulation PSIG High Pressure Venting of Regulators Sizing 3.5 Venting Systems and Air Supply for Appliances 4% Purposes Types of Venting Systems and Principles House as a System and Residential Depressurization Draft Control Materials Direct Vent Installation Practices Fan, Forced and Induced Vent Sizing Combustion Air Sizing Make-up Air Sizing up to 400 MBTU Make-up Air Systems 3.6 Pipe and Tubing Systems and Fittings 4% Materials and Practices Joints and Appliance Connections Volume and Pressure Drop Sizing Tables Sizing Low and 2 PSIG Manual Shut-offs Flexible Metallic Connectors and Hoses Testing Piping Systems
4 3.7 Electrical 15% Electrical Theory AC and DC Magnetism Series & Parallel Circuits Symbols Diagrams, Schematic and Ladder Millivolt Systems Volt Systems Circuit Testing Polarity and Phasing Thermocouples Powerpiles and Pilot Generators Components and Wiring Flame Rectification Troubleshooting Electrical Circuits 3.8 Appliances 15% B.C. Gas Code (Part 7 B149.1) Hot Air Furnaces and Duct Systems Boilers and Hot Water Heating Domestic Water Heaters, Storage and Tankless Residential Cooking Appliances Clothes Dryers Fireplaces Commercial Cooking Appliances (ranges, salamanders, deep fat fryers, char broilers, steamers, stockpot burners, wok cookers, griddles & convection ovens) Unit Heaters Roof Top Units Barbeques Infrared Heating Gas Refrigerators Conversion from other Fuels Direct Vent Space Heaters Wall Furnaces Miscellaneous Appliances 3.9 Burners 5% Principles Primary & Secondary Air (Requirements and Adjustments) Pilot Burners Burner Types Lifting, Flashback & Problems Orifice Types Pressure and Orifices
5 3.9.8 Orifice Tables & Sizing Input & Output Converting (Natural gas to/from Propane) High Altitude 3.10 Controls 10% Pilot Valves Limit Controls and Safety Switches Electric Valves Non-Electric Valves Combination Valves Water Heater Valves Gas Range Valves Oven Controls (Thermostats) Oven Safety Controls Griddle Thermostats Deep Fat Fryer Thermostats Boiler/Hot Water Aquastats Fireplace Control Valves Safety Shutoff Valves Flame Safeguard Systems Flame Rods Hot Surface Ignitors Spark Control Modules Hot Surface Ignitor Modules 3.11 Appliance Servicing 11% Wiring Diagrams Lubricating Gas Valves Controls Ignition Systems Troubleshooting Millivolt Systems Troubleshooting Electrical Problems Troubleshooting Venting Problems Troubleshooting Appliance Operation Troubleshooting Gas Fireplaces Troubleshooting Burner Operation Checking Regulators (Operation and Lock-up) Checking Heat Exchangers Commission of Appliances (Pressure set-up, Temperature Rise, Air Adjustment, Stack Temperature, Motor Amperage, CO, CO2, O2) Fan Motors Adjusting Fan Belts 3.12 Meter Clocking 3%
6 Gas Meter Operation Metric and Standard Meters Rotary Meters Clocking Formula Clocking Low Pressure Pressure Correction Factor Clocking 2 PSIG Clocking High Pressure
Gas Safety. Syllabus. For 120kW. Class B gas fitter. Certificate of qualification examination
Gas Safety Syllabus For 120kW Class B gas fitter Certificate of qualification examination *For individuals enrolled in a B level training course/program after April 01, 2009. Implementation date: January
More informationHVA 140 RESIDENTIAL HEATING
HVA 140 RESIDENTIAL HEATING PRESENTED AND APPROVED: AUGUST 9, 2012 EFFECTIVE: FALL 2013-14 Prefix & Number HVA 140 Course Title: Residential Heating Purpose of this submission: New X Change/Updated Retire
More informationCompleted Projects / Projets terminés
Completed Projects / Projets terminés New Standards New Editions Special Publications Gas Technician Training 2 Module 10, 3rd edition Piping and Tubing Systems for Industrial and Commercial Applications...
More informationPVE SERIES POWER VENTER SYSTEM MANUAL
PVE SERIES POWER VENTER SYSTEM MANUAL Contents Page I. Typical Venting System Components 2 II. System Operation 3 III. Power Venter Sizing 3,4 IV. Installation Safety Instructions 5,6 V. Installation of
More informationUSER S INFORMATION MANUAL
USER S INFORMATION MANUAL UPFLOW & DOWNFLOW/HORIZONTAL CONDENSING GAS FURNACES SAFETY Recognize this symbol as an indication of Important Safety Information If not installed, operated and maintained in
More informationOverview of Gas Range Types
Residential Gas Ranges Overview of Types How Carbon Monoxide is Emitted How They Operate Overview of Gas Range Types Rick Karg R.J. Karg Associates www.karg.com November 2001 2001 R.J. Karg Associates
More informationCombustion Safety. RESNET Conference San Antonio, TX February 27, Presented by Rich Moore Lightly Treading Energy & Design Denver, CO
Combustion Safety RESNET Conference San Antonio, TX February 27, 2006 Presented by Rich Moore Lightly Treading Energy & Design Denver, CO Goals of this session Recognize the need for combustion safety
More informationCOMBUSTION APPLIANCE SAFETY INSPECTION FOR VENTED APPLIANCES*
COMBUSTION APPLIANCE SAFETY INSPECTION FOR VENTED APPLIANCES* *Vented appliances refer to natural draft appliances equipped with a barometric draft regulator or Category I appliances equipped with a draft
More informationPOWER VENTER. Model: PVE Series
POWER VENTER Model: PVE Series CONTENTS Typical Venting System Components... System Operation... Power Venter Sizing... Installation Safety Instructions... Installation of Power Venter... Connecting Power
More informationStandard for tests for flammability of plastic materials for parts in devices and appliances
IAS Accreditation Number TL-212 Company Name Address 3933 U.S. Route 11 Cortland, NY 13045 Contact Name Terence J. O'Beirne, Quality Manager Telephone (607)758-6316 Effective Date of Scope September 25,
More informationCertification Information. Qualifications. Test Specifications. Gas Hydronics Industry References
GAS HYDRONICS INSTALLATION CERTIFICATION Certification Information Scope - Tests a candidate's knowledge of the installation, service, maintenance, and repair of hot water heating systems. System sizes
More informationUSER S INFORMATION MANUAL
USER S INFORMATION MANUAL UPFLOW/HORIZONTAL & DOWNFLOW TWO STAGE INDUCED DRAFT GAS FURNACES Recognize this symbol as an indication of Important Safety Information If the information in this manual is not
More informationSteamfitter-Pipefitter A Guide to Course Content
Steamfitter-Pipefitter A Guide to Course Content Steamfitter-Pipefitters install and repair low and high pressure piping systems and their components, including heating and processing applications. Steamfitter-pipefitters
More informationGas-fired water heaters, volume III, storage water heaters with input ratings above 75,000 Btu per hour, circulating and instantaneous
IAS Accreditation Number Company Name Address TL-657 Room 209, No. 46, Nanxiang 3 rd Road Science City Development Zone Guangzhou 510663 People s Republic of China Javen Xuan, Quality Manager Contact Name
More informationA. Section Common Motor Requirements for HVAC Equipment: Fan motors.
SECTION 235533 - FUEL-FIRED UNIT HEATERS PART 1 GENERAL 1.1 SECTION INCLUDES A. Gas fired unit heaters. B. Oil fired unit heaters. C. Tubular infrared heaters. 1.2 RELATED REQUIREMENTS A. Section 230513
More informationNatural Gas Appliance Testing Action Guidelines (Non ESA/Low Income 5 )
Natural Gas Appliance Testing Action Guidelines (n ESA/Low Income 5 ) The purpose of these Action Guidelines is to describe the actions participating contractors and/or inspectors should take in the event
More informationWARNING FIRE OR EXPLOSION HAZARD.
2017 Lennox Industries Inc. Dallas, Texas, USA 506897-01 04/2017 Supersedes 10/2015 EL280DF SERIES GAS FURNACE Improper installation, adjustment, alteration, service or maintenance can cause property damage,
More informationUSER S INFORMATION MANUAL
USER S INFORMATION MANUAL UPFLOW, DOWNFLOW, UPFLOW/HORIZONTAL & HORIZONTAL ONLY INDUCED DRAFT GAS FURNACES Recognize this symbol as an indication of Important Safety Information If the information in this
More informationSPECIFIC APPLIANCES CHAPTER 6
CHAPTER 6 SPECIFIC APPLIANCES SECTION FGC 601 GENERAL 601.1 Scope. This chapter shall govern the approval, design, installation, construction, maintenance, alteration and repair of the appliances and equipment
More informationMobile Vendors Bulletin
Mobile Vendors Bulletin NUMBER: 13-01 Amended Jan 18, 2016 PURPOSE City of Penticton Regulations for Mobile Vendors This guideline is intended to provide an overview of the City of Penticton requirements
More information4.3 Installing Appliances and Interior Vapor Distribution Systems Performance-Based Skills Assessment 2016
4.3 Installing Appliances and Interior Vapor Distribution Systems Performance-Based Skills Assessment 2016 Section One Task 1 Task 2 Task 3 Task 4 Task 5 Section Two Task 1 Task 2 Task 3 Task 4 Task 5
More informationIndiana WX Oil Furnace Inspection Guide
Indiana WX Oil Furnace Inspection Guide Client: Job # : Address: Phone: Client Interview: Oil Dealer: Date of last service: Comments/Billing information: Standard Inspection / Clean and Tune Follow-up:
More informationWhole House Combustion Appliance Safety Test Procedure for Pacific Gas and Electric Company (PG&E) Advanced Home Upgrade 2019
Whole House Combustion Appliance Safety Test Procedure for Pacific Gas and Electric Company (PG&E) Advanced Home Upgrade 2019 Note: This procedure is subject to revision or modification by PG&E at any
More informationCONVERSION TO PROPANE MANUAL M-Series Condensing Boiler. Wall-Mounted, Gas-Fired Boiler
rinnai.us 1-800-621-9419 CONVERSION TO PROPANE MANUAL M-Series Condensing Boiler Wall-Mounted, Gas-Fired Boiler For the Conversion from Natural Gas (NG) to Liquid Propane Gas (LPG) MODELS M060C M090C M120C
More informationWhole House Action Guidelines
for Pacific Gas and Electric Company's (PG&E) Whole House Rebate Progam 12/23/2011 The purpose of these Action Guidelines is to describe the actions participating contractors and/or inspectors should take
More informationSERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY
Bousquet Technologies Inc. 2121, Nobel, Ste Julie, Quebec, Canada, J3E1Z9 SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL Oil-Fired air heater for industrial and commercial use. FOR YOUR SAFETY Do not
More informationGAS TECHNICIAN. Program Outline
GAS TECHNICIAN Major: GAST Length: 1 Year Delivery: 3 Semesters Credential: Ontario College Certificate Effective: 2018-2019 Location: Barrie, Owen Sound Start: Fall (Barrie, Owen Sound) Program Outline
More informationCHAPTER 9 SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL BURNING EQUIPMENT
CHAPTER 9 SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL BURNING EQUIPMENT SECTION 901 GENERAL 901.1 Scope. This chapter shall govern the approval, design, installation, construction, maintenance, alteration
More informationWARNING FIRE OR EXPLOSION HAZARD.
2017 Lennox Industries Inc. Dallas, Texas, USA 506698-01 04/2017 Supersedes 10/2015 SL280DFV SERIES GAS FURNACE Improper installation, adjustment, alteration, service or maintenance can cause property
More informationSPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL-BURNING EQUIPMENT
CHAPTER 9 SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL-BURNING EQUIPMENT SECTION 901 GENERAL 901.1 Scope. This chapter shall govern the approval, design, installation, construction, maintenance, alteration
More information4.6 Advanced Propane Appliance Service and Troubleshooting Performance-Based Skills Assessment 2019
4.6 Advanced Propane Appliance Service and Troubleshooting Performance-Based Skills Assessment Section One Section Two Task 3 Task 4 Section Three Task 3 Section Four Section Five Task 3 Task 4 Task 5
More informationRECOMMENDED PROCEDURES FOR THIRD-PARTY PREVENTATIVE MAINTENANCE PROVIDERS
RECOMMENDED PROCEDURES FOR THIRD-PARTY PREVENTATIVE MAINTENANCE PROVIDERS 1 Contents Introduction... 3 Portfolio Energy Goals... 3 Purpose of This Document... 3 Gas Furnaces... 4 Electric Furnaces... 7
More informationSPECIFIC APPLIANCES CHAPTER 6
CHAPTER 6 SPECIFIC APPLIANCES SECTION 601 GENERAL 601.1 Scope. This chapter shall govern the approval, design, installation, construction, maintenance, alteration and repair of the appliances and equipment
More informationGAS-FIRED HIGH INTENSITY INFRARED HEATERS
GAS-FIRED HIGH INTENSITY INFRARED HEATERS CATALOG 9-116.1 MARCH, 2003 TABLE OF CONTENTS Modine's MT Series is a gas-fired, high intensity ceramic infrared heater. Ideal for spot heating, the MT series
More informationSPECIFIC APPLIANCES CHAPTER 6
CHAPTER 6 SPECIFIC APPLIANCES SECTION 601 (IFGC) GENERAL 601.1 Scope. This chapter shall govern the approval, design, installation, construction, maintenance, alteration and repair of the appliances and
More informationSPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL-BURNING EQUIPMENT
CHAPTER 9 SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL-BURNING EQUIPMENT SECTION 901 GENERAL 901.1 Scope. This chapter shall govern the approval, design, installation, construction, maintenance, alteration
More informationConstruction Heat CH-02 (up to 400,000 BTU) Record of Training Curriculum Document
Introduction: This TSSA document defines the required training curriculum content for CH-02 Record of Training programs under Ontario Regulation 215/01(Fuel Industry Certificates). Ontario Training Providers
More informationSAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER
SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER PART 1 GENERAL 1.01 RELATED DOCUMENTS A. ANSI Z21.13 American National Standard for Gas-Fired Low Pressure Steam and Hot Water Boilers B. ASME Section
More information4.5 Basic Propane Appliance Service and Troubleshooting Performance-Based Skills Assessment 2016
4.5 Basic Propane Appliance Service and Troubleshooting Performance-Based Skills Assessment 2016 Section One Section Two Section Three Task 3 Section Four Task 3 Section Five Section Six Section Seven
More informationQHT Manual for: SU-2A Gas Burner
1 QHT Manual for: SU-2A Gas Burner 50,000 BTU/H to 250,000 BTU/H The burner shall be used only with NATURAL GAS or LP GAS. Warning: If the following instructions are not followed exactly, a fire or explosion
More informationINSTALLATION GUIDE Dual Fuel Ranges
INSTALLATION GUIDE Dual Fuel Ranges Contents Wolf Dual Fuel Ranges......................... 3 Safety Instructions............................ 4 Dual Fuel Range Specifications.................. 5 Dual Fuel
More informationIndirect gas-fired air heater
Indirect gas-fired air heater SERIES HD INSTALLATION AND SERVICE MANUAL MANUFACTURED BY : BROTHERS LIMITED WARNING Improper installation, modification, adjustment or maintenance may cause damage, injury
More informationUSER S INFORMATION MANUAL
2017 Lennox Industries Inc. Dallas, Texas, USA 506737-01 04/2017 Supersedes 03/2017 USER S INFORMATION MANUAL EL195UHE SERIES GAS FURNACE Improper installation, adjustment, alteration, service or maintenance
More informationMANUAL WARNING FIRE OR EXPLOSION HAZARD. SL280UHNV SERIES WHAT TO DO IF YOU SMELL GAS:
U S E R S I N F O R M AT I O N MANUAL 2017 Lennox Industries Inc. Dallas, Texas, USA SL280UHNV SERIES 507650-01 10/2017 Improper installation, adjustment, alteration, service or maintenance can cause property
More informationService Manual For model N260 - a 2.4 cu. ft., 2-way refrigerator. For model N a 2.4 cu. ft., 3-way refrigerator.
Service Manual For model N260 - a 2.4 cu. ft., 2-way refrigerator. For model N260.3 - a 2.4 cu. ft., 3-way refrigerator. NORCOLD, Inc. P.O. Box 4248 Sidney, OH 45365-4248 Part No. 619260A (4-98) Table
More informationWARNING FLAIR INTERNATIONAL CORPORATION 600 OLD WILLETS PATH HAUPPAUGE, NEW YORK U.S.A. TEL.: (516) FAX: (516) AMERICAN
600 OLD WILLETS PATH HAUPPAUGE, NEW YORK 11788 U.S.A. TEL.: (516) 234-3600 FAX: (516) 234-3610 SPECIFICATIONS, INSTALLATION INSTRUCTIONS AND TROUBLE-SHOOTING GUIDE FOR STACK PACK MOTORIZED VENT DAMPER
More informationVICTORYII. Cast-iron, power vent gas boiler BOILER FOR OLDER HOMES.
VICTORYII Cast-iron, power vent gas boiler VHS SERIES are available in a sealed combustion model VSPH VICTORY BOILERS AN IDEAL REPLACEMENT BOILER FOR OLDER HOMES. A PERFECT BOILER FOR NEW CONSTRUCTION.
More informationPlumber A Guide to Course Content
Plumber A Guide to Course Content Plumbers install, replace and maintain water and sewage systems, and hydronic heating systems in residential, commercial and industrial buildings. They may also be licensed
More informationSECTION GAS-FIRED RADIANT HEATERS
SECTION 23 55 23 PART 1 - GENERAL 1.1 DESCRIPTION SPEC WRITER NOTES: 1. Use this section only for NCA projects. 2. Delete between // // if not applicable to project. Also delete any other item or paragraph
More informationOperating instructions
6304 0307 04/2005 US For the installer Operating instructions Sealed combustion boiler Logano GA24 SC and atmospheric boiler Logano G24X II/SP If these instructions are not followed exactly, a fire or
More informationConversion Instructions Logano G234X. Gas boiler. Please read carefully before installing and servicing. Gas boiler
Gas boiler UPON COMPLETION OF THE INSTALLATION THE INSTALLER MUST INSTRUCT THE OWNER AND OPERATOR ON THE FUNCTIONALITY AND THE PROPER OPERATION OF THE BOILER AND THE HEATING SYSTEM. INSTALLER MUST REVIEW
More informationHeating Maintenance and Repair
Heating Maintenance and Repair Electric Furnace Electric Baseboard Gas Furnace Hydronic Heating Disclaimer The use of photos of tools and/or components which clearly indicate their manufacturer or brand
More informationPOWER VENTER SYSTEM. Model: PVO-300, PVO-600
POWER VENTER SYSTEM Model: PVO-300, PVO-600 Included is one ETL and cetl listed Power Venter to be used primarily with a single 120VAC controlled oil fired furnace, boiler, or water heater. The PVO may
More informationSERVICE FACTS WARNING M801-SF-1C. Gas Furnaces Upflow & Downflow Induced Draft 1 Stage Heat Models: DISCONNECT POWER BEFORE SERVICING M801P040AU24AA
SERVICE FACTS Gas Furnaces Upflow & Downflow Induced Draft Stage Heat Models: M80P00AU2AA M80P060AU2AA M80P060AU36AA M80P080BU36AA M80P080BU8AA M80P00BU36AA M80P00CU8AA M80P00CU60AA M80PDU60AA M80P0DU60AA
More informationUSER S INFORMATION MANUAL
2005 Lennox Industries Inc. Dallas, Texas, USA USER S INFORMATION MANUAL 13GCSX SERIES UNITS GAS PACKAGED UNITS (2 5 TONS) Armstrong # 38152A068 505,058M 05/09 Supersedes 08/05 Table of Contents Litho
More informationRESNET National Conference New Orleans, LA. February 16, 2009 Presented by Rich Moore Invisible Energy Denver, CO
RESNET National Conference New Orleans, LA. February 16, 2009 Presented by Rich Moore Invisible Energy Denver, CO rgalenmoore1@msn.com This session will address the basics of combustion and the latest
More informationLABEL PLEASE NOTE: ALL APPLICATIONS AND SITE PLANS MUST BE COMPLETED IN BLACK OR BLUE INK ONLY
STAFF USE ONLY Thurston County Resource Stewardship 2000 Lakeridge Dr. S.W. Olympia, WA 98502 (360)786-5490 / (360)754-2939 (Fax) TDD Line (360) 754-2933 Email: permit@co.thurston.wa.us www.co.thurston.wa.us/permitting
More informationCommercial Kitchen Exhaust Requirements Kitchen Exhaust for Food Service Operations
Commercial Kitchen Exhaust Requirements Kitchen Exhaust for Food Service Operations District of Lake Country 10150 Bottom Wood Lake Road Lake Country, BC V4V 2M1 t: 250-766-6675 f: 250-766-0200 Inspection
More informationCombustion Appliance Safety Testing Guidelines
Combustion Appliance Safety Testing Guidelines This guide is intended to assist home performance contractors complete all combustion safety tests adequately and safely according to the Building Performance
More informationUSER S INFORMATION MANUAL SLP98UHV SERIES
2017 Lennox Industries Inc. Dallas, Texas, USA 506443-01 04/2017 Supersedes 10/2015 USER S INFORMATION MANUAL SLP98UHV SERIES VARIABLE CAPACITY GAS FURNACE Improper installation, adjustment, alteration,
More informationVF/VG700 Jumbo. Construction Heater. Installation and Maintenance Manual
342 N. Co. Rd. 400 East Valparaiso, IN 46383 888-432-8924 Fax 219-462-7985 www.heatwagon.com Installation and Maintenance Manual Please retain this manual for future reference. VF/VG700 Jumbo Construction
More informationINFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY:
INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS (CHECK ONE) PROPANE GAS PROJECT: ARCHITECT/ENGINEER: NAME: ADDRESS: NAME: ADDRESS: DATE: CONTRACTOR: SUBMITTED BY: NAME: ADDRESS: EQUIPMENT
More information90 HIGH EFFICIENCY UPFLOW GAS FURNACES
FORM NO. G66-477 Supersedes Form No. A11-152 Rev. 3 90 EFFICIENCY UPF GAS FURNACES 90RJ SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to 35.17 kw] (All Models 90% A.F.U.E. or Above)
More informationCHAPTER 6 SPECIFIC APPLIANCES
CHAPTER SPECIFIC APPLIANCES SECTION 01 (IFGC) GENERAL 01.1 Scope. This chapter shall govern the approval, design, installation, construction, maintenance, alteration and repair of the appliances and equipment
More informationUSER S INFORMATION MANUAL
USER S INFORMATION MANUAL UPFLOW & DOWNFLOW/HORIZONTAL TWO-STAGE SAFETY CONDENSING GAS FURNACES Recognize this symbol as an indication of Important Safety Information IMPORTANT: All manufacturer products
More informationML180UH SERIES GAS FURNACE WARNING WARNING
2017 Lennox Industries Inc. Dallas, Texas, USA 506525-01 04/2017 Supersedes 10/2015 ML180UH SERIES GAS FURNACE Improper installation, adjustment, alteration, service or maintenance can cause property damage,
More informationRESTAURANT SERIES EQUIPMENT
RESTAURANT SERIES EQUIPMENT built by craftsmen. tested by time. TRIM OFF TOUGH RELIABLE VERSATILE Bakers Pride has long been recognized as the tough, reliable, innovative provider to the food service industry.
More informationGood Ideas For Propane Safety
Good Ideas For Propane Safety What You Don't Know CAN Hurt You Safety...It's Up to You Propane is a safe, reliable fuel. Like many other fuels, however, it is flammable. That means it can be dangerous
More informationP.O. Box , Dallas, TX USER'S INFORMATION MANUAL Single-Stage Warm Air Gas Furnaces
P.O. Box 799900, Dallas, TX 75379-9900 USER'S INFORMATION MANUAL Single-Stage Warm Air Gas Furnaces This is a safety alert symbol and should never be ignored. When you see this symbol on labels or in manuals,
More informationDIRECTIVE NO: D-B
DIRECTIVE NO: D-B6 100604 1 LOW PRESSURE THERMAL FLUID PLANT AUTOMATED CONTROL SYSTEMS Date of Issue: June 4, 2010 General Details This directive is being issued to owners, licensed contractors, consulting
More informationHeating Basics Gas Valve Systems
Heating Basics Gas Valve Systems UNI-LINE PRODUCT KNOWLEDGE 2012 Invensys. All Rights Reserved. The names, logos, and taglines identifying the products and services of Invensys are proprietary marks of
More informationRetrofit Installer-Mechanical
Retrofit Installer-Mechanical Lesson Plan Section 1: Gas FurnaceFundamentals Learning Objectives By attending this session, participants will: Know the components of a gas furnace Understand the basic
More informationUser manual. Logano GC 124 II. Gas boiler
User manual Gas boiler WARNING! If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. B Do not store or use
More informationGAS-FIRED HIGH AND LOW INTENSITY INFRARED HEATERS
GAS-FIRED HIGH AND LOW INTENSITY INFRARED HEATERS MODEL IHR MODEL OHP MODEL IPT 9-123.2 SEPTEMBER, 2016 9-123.2 FEATURES AND BENEFITS - MODEL IHR Figure 4.1 - Construction Features - Model IHR Features
More informationX341119P10 Gas Furnace Var. Speed Blower Var. Speed Inducer Two Stage Heat Direct Vent Models:
Service Facts X349P0 Gas Furnace Var. Speed Blower Var. Speed Inducer Two Stage Heat Direct Vent Models: *UY060R9V3W *UY080R9V3W *UY00R9V4W *UY20R9V5W * First letter may be A or T *DY060R9V3W *DY080R9V3W
More informationNicor Gas Energy Efficiency Program. Business Customer Offerings
Nicor Gas Energy Efficiency Program Business Customer Offerings Agenda General Program Overview Prescriptive Program Custom Program June 1 and Beyond Program Effective Dates Pilot launched May 1, 2010
More informationINSTALLATION MANUAL. Rangetops. RNB Heritage Classic Platinum
INSTALLATION MANUAL Rangetops RNB Heritage Classic Platinum 1 BLUESTAR INSTALLATION INSTRUCTIONS FOR RANGETOPS MODELS RNB, Heritage Classic, Platinum THIS APPLIANCE WAS DESIGNED FOR EASE OF INSTALLATION
More informationOperating instructions
6 720 804 891 2012/10 EN-US For the installer Operating instructions Sealed combustion boiler Logano GA124 SC If these instructions are not followed exactly, a fire or explosion may be caused with serious
More informationState of ALASKA, Weatherization Assistance Program. Technical Support Document. Combustion Safety
5.3.1A(2) Page 1 of 2 State of ALASKA, Weatherization Assistance Program Technical Support Document Combustion Safety This document is intended to support in detail the Combustion Safety Test Report. The
More informationUNIT HEATER CATALOG. Form RZ-NA-C-UH (Version F)
UNIT HEATER CATALOG Form RZ-NA-C-UH (Version F) BACKGROUND Reznor was founded in 1888 to manufacture the Reznor reflector heater, which used a luminous flame gas burner developed by George Reznor. This
More informationBosch 80% AFUE Gas Furnace BGS80 Model
Bosch 80% AFUE Gas Furnace BGS80 Model 4-Way Multipoise Category I Fan-Assisted Furnace User's Information Manual 3124627 2 Bosch 80% AFUE Gas Furnace User's Information Manual Data subject to change 06.2018
More informationExperienced Worker Assessment Blueprint HVAC - Heating, Ventilation and Air Conditioning
Blueprint HVAC - Heating, Ventilation and Air Conditioning Test Code: 0144 / Version: 02 Specific Competencies and Skills Tested in this Assessment: Electricity Demonstrate understanding of basic AC/DC
More informationDEFINITIONS CHAPTER 2
CHAPTER 2 DEFINITIONS SECTION 201 (IFGC) GENERAL 201.1 Scope. Unless otherwise expressly stated, the following words and terms shall, for the purposes of this code and standard, have the meanings indicated
More informationOPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS
OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For FVN/P-400 INDIRECT FIRED SPACE HEATERS CERTIFIED FOR USE IN CANADA AND U.S.A. As per Standard ANSI Z83.7/CSA 21.4 2000 Gas Fired Construction
More informationUSER S, MAINTENANCE and SERVICE INFORMATION MANUAL
CONTENTS SAFETY INFORMATION................ 2 FOR YOUR SAFETY...................... 2 SYSTEM OPERATION.................. 2 THERMOSTATS.......................... 2 INTERMITTENT IGNITION DEVICE..........
More informationCity of Gainesville Inspection Permitting Fees Effective July 1, 2012
City of Gainesville Inspection Permitting Effective July 1, 2012 BUILDING PERMITS New Construction of Residential Homes 0-200 square feet $40.00 Plus additional cost per square foot over 200 $0.20 Home
More informationProduct Data BW9 WATER BOILER SERIES B
GAS --- FIRED CONDENSING WATER BOILER SERIES B Product Data Fig. 1 - Model 50-100 Series B Fig. 2 - Model 125-200 Series B C US Use of the AHRI Certified TM Mark indicates a manufacturer s participation
More informationLATTNER BOILER COMPANY 9.5 HP Low-NOx Installation and Start-Up Checklist for Dry Cleaners
1 1. General Installation Information (to be completed by technician) Date installed: Location (city & state): Cleaner s name: National Board number (boiler): Installed by (company): Installed by (technician):
More informationTABLE OF CONTENTS. Part I Administrative... 1
Part I Administrative............................ 1 CHAPTER 1 Deleted Part II Definitions.............................. 3 CHAPTER 2 DEFINITIONS.................... 3 R201 General..................................
More informationon a 98 percent AFUE furnace, less water vapor passes into the vent.
Welcome to the training module for vent and combustion air system design and installation for the new 35 inch condensing furnace. This module will take about 20 minutes to complete. 1 This training module
More informationBuilding Department Informational Handout
City of Sonoma Building Department Informational Handout Residential Water Heaters Handout No: 15 Revised: 4/26/18 A water heater is an appliance designed to supply hot water and is equipped with automatic
More informationINSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG FIRE PIT SERIES ONLY
INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG FIRE PIT SERIES ONLY Installation and service must be provided by a qualified installer, service agency or gas supplier Grand Canyon Gas Logs,
More information(Text with EEA relevance) Reference and title of the harmonised standard (and reference document) EN 26:1997/A1:2000 Note 3 Date expired (18.7.
C 349/6 Official Journal of the European Union 22.12.2010 Commission communication in the framework of the implementation of the European Parliament and the Council Directive 2009/142/EC relating to appliances
More informationIs a heating protection plan really worth it? Decide for yourself!
Is a heating protection plan really worth it? Decide for yourself! Priority Customer Service Our customers are important to us. We make you a priority by putting you at the top of the list. Add Years to
More informationOPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS
OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For FVN/P-400 INDIRECT FIRED SPACE HEATERS CERTIFIED FOR USE IN CANADA AND U.S.A. As per Standard ANSI Z83.7/CSA 21.4 2000 Gas Fired Construction
More informationSTR-Series Indirect-Fired Air Turnover Units
STR-Series Indirect-Fired Air Turnover Units Equipment Specifi cations 1.800.589.3691 www.weather-rite.com GAS/OIL HEATING ONLY INDIRECT-FIRED AIR TURNOVER UNIT GUIDE SPECIFICATIONS PART 1 GENERAL [Gas][Oil][Gas/Oil
More informationSTAR-MAX PROPANE GAS GRIDDLE
Star Manufacturing International Inc. 10 Sunnen Drive St. Louis, MO 63143 Phone: (314) 781-2777 Fax: (314) 781-3636 Installation and Operating Instructions 2M-Z3793 Rev. B 3/28/03 STAR-MAX PROPANE GAS
More informationFEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).
This document was created with FrameMaker 4.0.4 SIZES AVAILABLE: 024065 through 060150 EFFICIENCY: IGNITION: HEAT EXCHANGER: CONTROL BOARD: The GA1A Induced-Combustion Gas Furnace provides the efficiency
More informationGAS SAFETY REGULATION
Safety Standards Act B.C. Reg. 103/2004 Deposited March 23, 2004 and effective April 1, 2004 Last amended August 31, 2018 by B.C. Reg. 170/2018 Consolidated Regulations of British Columbia This is an unofficial
More informationModel No: Little Devil II (inc ss)
GAS HEATER Model No: Little Devil II (inc ss) PART NO: 6926020, 6926025 (SS) OPERATION & MAINTENANCE INSTRUCTIONS LS1213 INTRODUCTION Thank you for purchasing this CLARKE Gas Heater. Before attempting
More information