know exactly what you are getting before you order it. You can order with confidence knowing th each panel is completely tested before it ships.

Size: px
Start display at page:

Download "know exactly what you are getting before you order it. You can order with confidence knowing th each panel is completely tested before it ships."

Transcription

1 y y y

2 Imagine know exactly what you are getting before you order it. You can order with confidence knowing th each panel is completely tested before it ships. Quick-ship panels are available for almost any type of boiler, with or without outdoor reset. Imagine the ability to send boiler temp, thermostatically mixed temperature, or reset modulated water to indirect water heaters, baseboard, fancoils, radiant slabs, or staple-up. With HydroNex, you can scale up from a few zones to more than 50 zones using the same proven building block approach. The HydroNex System is based on proven Primary/Secondary y (P/S) piping. p With P/S you know exactly what is happening at all times. With HydroNex you eliminate ghost flows and call backs with check and service valves, valved flanges, unions, and pressure/temperature gauges. As easily as 1-2-3, Primary panels move heat through (1) the boiler and primary loop, (2) Distribution panels send heat to each zone, and (3) Z Panels distribute the heat to radiant circuits, (or other terminal units). Experienced contractors will find many uses for these panels to speed up and simplify the design, quoting, and installation process, both in new and retrofit systems. With the HydroNex system, logic is visual. You can easily, and almost intuitively trace out fluid flows to each zone, check for air-locked circuits, and verify the entire system is functioning correctly before you leave. All plumbing and electrical components are easy to access for quick service. A good-looking g HydroNex system adds to customer satisfaction. They can even increase the resale value of your customer s home or office. Less time in the field and fewer call-backs means more time for your family and friends. Follow the selection process in the next few pages, or call the friendly people at Watts Radiant for free design assistance for your next job.

3 P Panels D Panels DVIP Weather responsive control sends variable temperature water to each zone. DVIP-ZoneValve Similar to DVIP but uses zone valves with a single load pump to distribute water to zones. DMixHybrid One panel delivers two temperatures! You choose boiler temperature and mix valve options. Perfect for indirect DHW and radiant. DVIPHybrid One panel delivers two temperatures! You choose boiler temperature and weather-responsive control. Great for indirect DHW and radiant. DHX-S Add snowmelt or any other indirect heating application to your system. Z Panels (Zone panels) Stainless steel 1 manifolds distribute water to radiant, baseboard, or fancoils. Order with or without pre-wired actuators. Pre-installed in steel cabinets for each in the wall installation. ZPump and ZMixPumpZone panels are often used to add zones to existing boiler systems. ZZone Manifolds only, requires a supply line with a circulator, such as a D Panel. ZPumpZone This panel includes its own circulator, good for high temperature zones. Use for add on zones to existing boiler systems. ZMixPumpZone This panel adds a thermostatic (non-electric) mix valve to the ZPumpZone panel. S Panels These panels are designed to expand the capabilities of the HydroNex line, giving you more design options for energy saving systems. Condensing Boiler Panel Specifically designed to interface with most condensing boilers, this panel also includes many primary panel functions. GeoThermal Panel This panel makes using a ground source heat pump easy; simply add the panel to your HydroNex package and enjoy the matchless efficiency of geothermal and radiant. VIP Mechanical Room Panel A stand-alone, weather responsive, variable-speed injection pump panel. When selecting your HydroNex modular control panels, think Primary Distribution Zone Special, or PDZS.

4 92 Q1. Do you have a glycol-filled system? Pick a PMan panel, with the manual fill option. P (Primary) Panel Selection Answer these questions to select the correct P Panel. Q2. Do you want the convenience of an automatic fill feature? Select the PAuto panel with the built in Watts 9-11s M-3 Backflow Preventer/Boiler Fill Valve. Do not select the PAuto panel if you are using a glycol-filled system, as the glycol may be diluted, without your knowledge. Q3. Do you want the energy saving option of an automatic reset control, that changes the boiler system water temperature as outside air temperature changes? Order a Primary panel (PManR or PAutoR) with a boiler outdoor reset control. D (Distribution) Panel Selection Answer these questions to select the correct D Panel(s). Q1. Do you want the supply water temperature to a zone to be the boiler temperature? Use a DDirect Panel, which pumps straight boiler (primary loop) temperature water. Perfect for radiators, fancoils, indirect water heaters, and some staple-up. Q2. Do you want the supply water to one or more zones mixed to a lower (fixed) temperature than your boiler (primary loop) is set at? Use a DMix to deliver a fixed supply temperature. Q3. Do you need some zones supplied with boiler temperature water and some zones supplied with fixed, lower temp fluid? Use a DMixHybrid Panel. This unique panel lets you field-select how many zones will be supplied with boiler-temperature water, and how many zones will be supplied with a fixed, lower temp water. Q4. Do you want the supply water temperature to respond to outdoor weather conditions? Use a DVIP Panel. Each DVIP Panel can supply up to five zones. If you have two areas that need outdoor reset control, but require different supply temperatures, order two DVIP Panels. Q5. Do you need some zones to respond to outdoor weather conditions, and some zone supply temps to be fixed; such as an indirect water heater? Use a DVIPHybrid Panel. This unique panel lets you field-select how many zones will be supplied with boiler-temperature water and how many zones will have their water temperature adjusted by an outdoor reset control. Q6. Do you want the supply water temperature to respond to outdoor weather conditions, have up to 6 zones, and minimize the number of pumps in your system? Use a DVIP ZoneValve Panel with only one zone pump. Q7. Do you want to add snowmelt or heat exchanger capabilities to your system? Use a DHX-S panel. Various control options allow the user flexibilty in choosing the application of this panel. NOTE: You can mix and match two or more D Panels in a single project. For example, you may use DDirect Panels to supply all of your baseboard zones, while using a DVIP Panel to supply radiant slab zones.

5 93 Z (Zone) Panel Selection Z Panels empower Watts Radiant s well-known 1 stainless steel manifolds for many uses. These include radiant zones, or supplying smaller terminal units such as kickspace heaters, towel warmers, or radiators. ZZone panels can supply between 2 and 12 zones, while ZMix and ZMixPump panels can supply between 2 and 7 zones. Note: A designates panels where each circuit is pre-wired with an individual actuator. Each circuit can deliver 2gpm. Actuators can easily be field jumpered to feed larger zones. Q1. Are you using D Panels (or field-installed zone pumps)? Select a ZZone panel (without actuators) for a single zone. For supplying multiplezones from a single manifold, use a ZZoneA panel (with actuators). Q2. Are you supplying a radiant manifold, radiators, or other equipment directly off the boiler? The ZPumpZone is the right choice, combining a manifold with a dedicated zone pump. Use the ZPumpZoneA if the manifold is supplying multiple zones. Q3. Do you want to supply a fixed supply water temperature to a radiant floor or other zone? The ZMixPumpZone combines a zone pump, and field adjustable thermostatic mix valve. Use a ZMixPumpZoneA for feeding multiple zones. S (Special) Panel Selection Answer these questions to select the correct S Panel(s) Q1. Are you using a modular condensing boiler as a heat source? Select a Condensing Boiler Panel. This panel makes it easy to enjoy the efficiency of a condensing boiler. Q2. Are you using a ground source heat pump as a heat source? Select a GeoThermal Panel. Seamlessly integrate a ground source heat pump into your radiant system for unparalleled efficiency. Q3. Do you need weather-responsive outdoor reset control and the ability to use larger, or different circulators? Select a VIP mechanical panel. If you have any further questions, or require assistance selecting the HydroNex system best-suited to your project, please call our system designers who are always willing to help:

6 94 PMan Panel P-Series panels are primary panels designed to supply down-stream panels with boiler water, which will in turn distribute boiler water to the radiant or other hydronic heating zones. They also remove air and provide essential service and monitoring capabilities. Plumbed in 1.25 L copper, these units are also equipped with Watts quick-connect unions for quick coupling to other HydroNex panels. All P Panels come pre-wired with a 9 power supply cord and measure 28 wide x 31.5 tall x 12 deep (S). Standard equipment includes: High performance micro-bubble air remover Primary loop pump of your choice Watts isolation pump flange Service valves 0-50psi/60-320F gauge White, powder-coated steel enclosure PAuto Panel The PAuto Panel is the same as the PMan Panel, but includes the Watts 9-11S M3 backflow preventer/auto boiler fill valve. This assembly also functions as a pressure-regulating, dual check-valve backflow preventer with atmospheric vent. The panel is plumbed in 1.25 L copper and equipped with Watts quickconnect unions to quick coupling to other HydroNex panels. Controls Every P Panel comes with a pre-wired switching control. It turns on the P Panel s primary pump and closes a dry contact for the boiler Aquastat upon a call for heat from any source. The panel comes with a 9 power supply cord for quick and easy field installation. 28 wide x 31.5 tall x 12 deep P Panel, Manual Fill, Watts Radiant Pump PManWR S P Panel, Manual Fill, Taco 008 Pump PManTA S P Panel, Manual Fill, Taco 0011 Pump PManTA S P Panel, Manual Fill, Bell & Gossett NRF-22 Pump PManBGNRF S P Panel, Manual Fill, Bell & Gossett PL-30 Pump PManBGPL S P Panel, Auto Fill, Watts Radiant Pump PAutoWR S P Panel, Auto Fill, Taco 008 Pump PAutoTA S P Panel, Auto Fill, Taco 0011 Pump PAutoTA S P Panel, Auto Fill, Bell & Gossett NRF-22 Pump PAutoBGNRF S P Panel, Auto Fill, Bell & Gossett PL-30 Pump PAutoBGPL S

7 95 Upgrade any Primary Panel with a pre-wired Tekmar 256 microprocessor-based one-stage boiler control. This control monitors the outside conditions and the boiler temperature to regulate the supply temperature sent to your heating system. To avoid boiler short cycling and large temperature swings, the 256 control continuously adjusts the boiler differential. Note: Do not use a Primary panel with reset if you are using a DVIP or DVIPHybrid panel (which includes its own reset control). PManR Panel Standard equipment on the PMan R Panel includes: Pre-wired Tekmar 256 control High performance micro-bubble air remover Primary loop pump of your choice Watts isolation pump flange Service valves 0-50psi/60-320F gauge White, powder-coated steel enclosure with cover Watts purge valve for easy air removal Plumbed in 1.25 L copper, these units are also equipped with Watts quick-connect unions for quick coupling to other HydroNex panels. All P Panels come pre-wired with a 9 power supply cord and measure 28 wide x 31.5 tall x 12 deep (S). PAutoR Panel The PAutoR Panel is the same as the PManR Panel, but includes the Watts 9-11S M3 backflow preventer/auto boiler fill valve. This assembly functions as a pressure-regulating, dual check-valve backflow preventer with atmospheric vent. The panel is plumbed in 1.25 L copper and equipped with Watts quick-connect unions to quick coupling to other HydroNex panels. 28 wide x 31.5 tall x 12 deep P Panel, Manual Fill, Outdoor Reset, Watts Radiant Pump PManRWR S P Panel, Manual Fill, Outdoor Reset, Taco 008 Pump PManRTA S P Panel, Manual Fill, Outdoor Reset, Taco 0011 Pump PManRTA S P Panel, Manual Fill, Outdoor Reset, Bell & Gossett NRF-22 PManRBGNRF S P Panel, Manual Fill, Outdoor Reset, Bell & Gossett PL-30 PManRBGPL S P Panel, Auto Fill, Outdoor Reset, Watts Radiant Pump PAutoRWR S P Panel, Auto Fill, Outdoor Reset, Taco 008 Pump PAutoRTA S P Panel, Auto Fill, Outdoor Reset, Taco 0011 Pump PAutoRTA S P Panel, Auto Fill, Outdoor Reset, Bell & Gossett NRF-22 PAutoRBGNRF S P Panel, Auto Fill, Outdoor Reset, Bell & Gossett PL-30 PAutoRBGPL S

8 96 DDirect Panels These panels are perfect for radiators, fan coils, staple-up, underfloor radiant, kickspace heaters, indirect water heaters or just about any radiant application. Each panel comes completely pre-wired and the 1.25 L copper main line is equipped with Watts quick-connect unions for easy field connection to a P Panel and/or other D Panels. Includes 9 power cord. Standard equipment on each panel includes: 1-5 independently controlled and pre-wired zone pumps of your choice 1 spring check valve (one per zone) 2 isolation ball valves per pump Pre-wired pump control 0-50psi/60-320F gauge White, powder-coated steel enclosure with cover Watts purge valve for easy air removal Controls The multi-zone control comes completely pre-wired. Under certain conditions, such as with the use of a condensing boiler, Direct panels can be connected directly to the heat source, provided the following conditions apply: Proper flow is maintained through the heat source. Heat source can be set to desired temperature setting (no mixing required). No minimum return fluid temperature is required for the heat source. All necessary conditions and piping practices, as outlined by the heat source manufacturer, are properly maintained. S = 28 wide x 31.5 tall x 12 deep M = 40 wide x 31.5 tall x 12 deep L = 52 wide x 31.5 tall x 12 deep DDirect Panel, 1 Watts Radiant Pump DDirect1WR S DDirect Panel, 2 Watts Radiant Pumps DDirect2WR S DDirect Panel, 3 Watts Radiant Pumps DDirect3WR M DDirect Panel, 4 Watts Radiant Pumps DDirect4WR L DDirect Panel, 5 Watts Radiant Pumps DDirect5WR L DDirect Panel, 1 Taco 007 Pump DDirect1TA S DDirect Panel, 2 Taco 007 Pumps DDirect2TA S DDirect Panel, 3 Taco 007 Pumps DDirect3TA M DDirect Panel, 4 Taco 007 Pumps DDirect4TA L DDirect Panel, 5 Taco 007 Pumps DDirect5TA L DDirect Panel, 1 Bell & Gossett NRF-22 Pump DDirect1BGNRF S DDirect Panel, 2 Bell & Gossett NRF-22 Pumps DDirect2BGNRF S DDirect Panel, 3 Bell & Gossett NRF-22 Pumps DDirect3BGNRF M DDirect Panel, 4 Bell & Gossett NRF-22 Pumps DDirect4BGNRF L DDirect Panel, e, 5 Bell & Gossett NRF-22 Pumps DDirect5BGNRF L

9 97 DMix Panels The DMix Series of panels is ideal for any system that uses lower temperature water, such as radiant manifolds, panel radiators or fan coils. Temperatures between 100 and 160 F can be achieved using the field-adjustable, thermostatic mix valve. The included Watts temperature gauge makes temperature adjustment quick and accurate. All zone pumps are pre-wired to a built-in zone control. Caution: This mix valve can supply up to three pumps, as long as the total combined flow of the three pumps does not exceed 3.2 gpm (32,000 BTU/h). Each DMix Panel is plumbed with 1.25 L copper main line, and is supplied with Watts quick-connect unions for easy field connection to a P or other D Panels. Standard equipment for DMix Panels include: 1-3 independently controlled and pre-wired zone pumps of your choice 1 field-adjustable, thermostatic mix valve 3/4 spring check valve (one per zone) 1 isolation ball valve per pump 2 isolation ball valves for field-service of mix valve Pre-wired pump control 0-50psi/60-320F gauge White, powder-coated steel enclosure with cover Watts purge valve for easy air removal Controls The multi-zone control comes completely pre-wired and tested. Each panel is supplied with a 9 power supply cord. Zone delivery temperature can be regulated and verified by adjusting the mix valve knob and checking the output on the down-stream temperature gauge. S = 28 wide x 31.5 tall x 12 deep M = 40 wide x 31.5 tall x 12 deep DMix Valve Panel, 1 Watts Radiant Pump DMixV1WR S DMix Valve Panel, 2 Watts Radiant Pumps DMixV2WR M DMix Valve Panel, 3 Watts Radiant Pumps DMixV3WR M DMix Valve Panel, 1 Taco 007 Pump DMixV1TA S DMix Valve Panel, 2 Taco 007 Pumps DMixV2TA M DMix Valve Panel, 3 Taco 007 Pumps DMixV3TA M DMix Valve Panel, 1 Bell & Gossett NRF-22 Pump DMixV1BGNRF S DMix Valve Panel, 2 Bell & Gossett NRF-22 Pumps DMixV2BGNRF M DMix Valve Panel, 3 Bell & Gossett NRF-22 Pumps DMixV3BGNRF M

10 98 DMixHybrid Panels The DMix-Hybrid Panel allows the flexibility to choose which zones get direct boiler water and which get tempered water from the mix valve. An example might be a system that has two radiant slab zones (tempered supply) and a baseboard zone or indirect water heater (direct boiler water). Selecting which zones are boiler or mix valve-fed is as easy as opening or closing the appropriate valve(s). Temperatures between 100 and 160 F can be achieved using the field-adjustable, thermostatic mix valve. The included Watts gauge makes temperature adjustment easy and precise. This mix valve can supply up to three pumps, as long as the total combined flow of the three pumps does not exceed 3.2 gpm (32,000 BTU/h at 20F deltat). All zone pumps are pre-wired to a built-in zone control. Each DMix-Hybrid Panel is plumbed with 1.25 L copper main line, and is supplied with Watts quick-connect unions for easy field connection to a P or other D Panels. Standard equipment for DMix-Hybrid Panels include: 2-4 independently controlled and pre-wired zone pumps of your choice 1 field-adjustable, thermostatic mix valve 3/4 spring check valve (one per zone) 2-3 ball valves for selecting boiler or injection pump-fed zones 1 isolation ball valve per pump 2 isolation ball valves for field-service of mix valve Pre-wired pump control 0-50psi/60-320F gauge Watts RPV valve for easy zone purging White, powder-coated steel enclosure with cover Controls The multi-zone control comes completely pre-wired; each zone pump and control are factory-wired and tested. Each panel is supplied with a 9 power supply cord. Zone delivery temperature can be regulated and verified by adjusting the mix valve knob and checking the output on the down-stream temperature gauge. The control can easily be modified to prioritize domestic hot water, ensuring that your household has a plentiful supply of hot water. M = 40 wide x 31.5 tall x 12 deep L = 52 wide x 31.5 tall x 12 deep DMixHybrid Panel, 2 Watts Radiant Pumps DMixV2HybridWR M DMixHybrid Panel, 3 Watts Radiant Pumps DMixV3HybridWR M DMixHybrid Panel, 4 Watts Radiant Pumps DMixV4HybridWR L DMixHybrid Panel, 2 Taco 007 Pumps DMixV2HybridTA M DMixHybrid Panel, 3 Taco 007 Pumps DMixV3HybridTA M DMixHybrid Panel, 4 Taco 007 Pumps DMixV4HybridTA L DMixHybrid Panel, 2 Bell & Gossett NRF-22 Pumps DMixV2HybridBGNRF M DMixHybrid Panel, 3 Bell & Gossett NRF-22 Pumps DMixV3HybridBGNRF M DMixHybrid Panel, 4 Bell & Gossett NRF-22 Pumps DMixV4HybridBGNRF L

11 99 DVIP Panels The DVIP series of panels deliver automatically adjusted, weather-responsive heat to your systems. These panels reset the system water temperature with changes in the outdoor conditions. The Tekmar 361 adjusts the speed of the variable-speed pump, regulating the flow of boiler water into your radiant loops. This is a simpler, more reliable and more cost-effective approach than the old motorized mixing valves. The same temperature water will be delivered to all zones. Each Panel is plumbed with 1.25 L copper main line, and is supplied with Watts quickconnect unions for easy field connection to other HydroNex Panels. Standard equipment for DVIP Panels include: 1 variable-speed injection pump of your choice 1 Tekmar 361 variable-speed digital outdoor reset control 1-5 independently controlled and pre-wired zone pumps of your choice 3/4 spring check valve (one per zone) 1 isolation ball valve per pump Pre-wired pump control 0-50psi/60-320F gauge Watts RPV valve for easy zone purging White, powder-coated steel enclosure with cover Controls The multi-zone control comes completely pre-wired and tested. Each panel is supplied with a 9 power supply cord. Note: Do not use this panel if you are using a reset control on your boiler, or a Primary panel with a reset control. S = 28 wide x 31.5 tall x 12 deep M = 40 wide x 31.5 tall x 12 deep L = 52 wide x 31.5 tall x 12 deep DVIP Panel, 1 Watts Radiant Pump DVIP1WR S DVIP Panel, 2 Watts Radiant Pumps DVIP2WR M DVIP Panel, 3 Watts Radiant Pumps DVIP3WR M DVIP Panel, 4 Watts Radiant Pumps DVIP4WR L DVIP Panel, 5 Watts Radiant Pumps DVIP5WR L DVIP Panel, 1 Taco 007 Pump DVIP1TA S DVIP Panel, 2 Taco 007 Pumps DVIP2TA M DVIP Panel, 3 Taco 007 Pumps DVIP3TA M DVIP Panel, 4 Taco 007 Pumps DVIP4TA L DVIP Panel, 5 Taco 007 Pumps DVIP5TA L DVIP Panel, 1 Bell & Gossett NRF-22 Pump DVIP1BGNRF S DVIP Panel, 2 Bell & Gossett NRF-22 Pumps DVIP2BGNRF M DVIP Panel, 3 Bell & Gossett NRF-22 Pumps DVIP3BGNRF M DVIP Panel, 4 Bell & Gossett NRF-22 Pumps DVIP4BGNRF L DVIP Panel, e, 5 Bell & Gossett NRF-22 Pumps DVIP5BGNRF L

12 100 DVIP-Hybrid Panels The DVIP-Hybrid Panel allows the flexibility to choose which zones get direct boiler water and which get tempered water from the injection pump. Selecting which zones are boiler or injection pump-fed is as easy as opening or closing the appropriate valve(s). These panels reset the system water temperature with changes in the outdoor conditions. The Tekmar 361 adjusts the speed of of the variable-speed pump, regulating the flow of boiler water into your radiant loops. This is a simpler, more reliable and cost-effective approach than the old motorized mixing valves. Each Panel is plumbed with 1.25 L copper main line, and is supplied with Watts quick-connect unions for easy field connection to other HydroNex Panels. Standard equipment for DVIP-Hybrid Panels include: 1 variable-speed injection pump of your choice 1 Tekmar 361 variable-speed, digital, outdoor reset control 2-5 independently controlled and pre-wired zone pumps of your choice 2-5 ball valves for selecting boiler or injection pump-fed zones 3/4 spring check valve (one per zone) 1 isolation ball valve per pump Pre-wired pump control 0-50psi/60-320F gauge Watts RPV valve for easy zone purging White, powder-coated steel enclosure with cover M = 40 wide x 31.5 tall x 12 deep L = 52 wide x 31.5 tall x 12 deep Controls The multi-zone control comes completely pre-wired and tested. Each panel is supplied with a 9 power supply cord. The control can easily be modified to prioritize domestic hot water, ensuring that your household has a plentiful supply of hot water. Note: Do not use this panel if you are using a reset control on your boiler, or a Primary panel with a reset control. DVIP-Hybrid Panel, 2 Watts Radiant Pumps DVIP2HybridWR M DVIP-Hybrid Panel, 3 Watts Radiant Pumps DVIP3HybridWR M DVIP-Hybrid Panel, 4 Watts Radiant Pumps DVIP4HybridWR L DVIP-Hybrid Panel, 5 Watts Radiant Pumps DVIP5HybridWR L DVIP-Hybrid Panel, 2 Taco 007 Pumps DVIP2HybridTA M DVIP-Hybrid Panel, 3 Taco 007 Pumps DVIP3HybridTA M DVIP-Hybrid Panel, 4 Taco 007 Pumps DVIP4HybridTA L DVIP-Hybrid Panel, 5 Taco 007 Pumps DVIP5HybridTA L DVIP-Hybrid Panel, 2 Bell & Gossett NRF-22 Pumps DVIP2HybridBGNRF M DVIP-Hybrid Panel, 3 Bell & Gossett NRF-22 Pumps DVIP3HybridBGNRF M DVIP-Hybrid Panel, 4 Bell & Gossett NRF-22 Pumps DVIP4HybridBGNRF L DVIP-Hybrid Panel, 5 Bell & Gossett NRF-22 Pumps DVIP5HybridBGNRF L

13 101 M = 40 wide x 31.5 tall x 12 deep L = 52 wide x 31.5 tall x 12 deep DVIP-ZoneValve DVIP-ZoneValve panels are ideal when using zone valves to supply weather sensitive hydronic systems. As the outside weather changes, the panel changes the water temperature supplied to the zone valves. Applications include radiant slabs, radiators, fan coils and staple-up. All of the actuators, pumps and controls come completely pre-wired. Standard equipment on the DVIP-ZoneValve panel includes: Pre-wired zone pump and zone valve actuator controls Pre-wired injection mixing pump and controls 2-6 circuits with individual zone valves (max 2gpm per circuit) Pressure differential by-pass valve Isolation ball valves on each zone and pump Pressure and temperature gauge Cat 5e connection Controls The DVIP ZoneValve panel comes standard with variable speed injection mixing controlled by a weather responsive Tekmar 361 injection control. Panels come with 2 through 6 circuits; each circuit can be controlled by a separate thermostat, or multiple circuits can be combined to service larger zone(s). Panels come with all zone valve actuators and pumps pre-wired. Each zone valve is thermostatically activated by a call for heat, activating both the zone pump and injection pump. Inter-panel communication is achieved by Cat 5e plug and play cables. Note that all circuits are supplied with the same water temperature. If multiple zones are serviced by the same panel,all zones should have similar supply temperatures. Note: Limited availability until April Circuit DVIP Panel with Zone Valves, Watts Radiant Pumps DVIPZV2WR M 3 Circuit DVIP Panel with Zone Valves, Watts Radiant Pumps DVIPZV3WR M 4 Circuit DVIP Panel with Zone Valves, Watts Radiant Pumps DVIPZV4WR M 5 Circuit DVIP Panel with Zone Valves, Watts Radiant Pumps DVIPZV5WR L 6 Circuit DVIP Panel with Zone Valves, Watts Radiant Pumps DVIPZV6WR L 2 Circuit DVIP Panel with Zone Valves, Taco 007 Pumps DVIPZV2TA M 3 Circuit DVIP Panel with Zone Valves, Taco 007 Pumps DVIPZV3TA M 4 Circuit DVIP Panel with Zone Valves, Taco 007 Pumps DVIPZV4TA M 5 Circuit DVIP Panel with Zone Valves, Taco 007 Pumps DVIPZV5TA L 6 Circuit DVIP Panel with Zone Valves, Taco 0010 Pumps DVIPZV6TA L 2 Circuit DVIP Panel with Zone Valves, Bell & Gossett NRF-22 Pumps DVIPZV2BGNRF M 3 Circuit DVIP Panel with Zone Valves, Bell & Gossett NRF-22 Pumps DVIPZV3BGNRF M 4 Circuit DVIP Panel with Zone Valves, Bell & Gossett NRF-22 Pumps DVIPZV4BGNRF M 5 Circuit DVIP Panel with Zone Valves, Bell & Gossett NRF-22 Pumps DVIPZV5BGNRF L 6 Circuit DVIP Panel with Zone Valves, Bell & Gossett NRF-33 Pumps DVIPZV6BGNRF L

14 102 DHX-S Panels DHX-S panels make it easy to add snowmelting to any HydroNex system. Two highly effective heat exchanger options offer high output and fast response time. The two models currently available offer maximum outputs up to 150,00 BTU/Hr(150 M BH) or 250,000 BTU/Hr(250 MBH) based on nominal 180 o F boiler temp, 130 o F snowmelt temp, and 30F delta tee. Actual output may be more or less, depending on your project. The pumps and heat exchanger are provided with service valves for easy access. This panel can also be used in other applications requiring a heat exchanger when ordered with the Tekmar 361 control. Potential applications include a glycol loop for a garage, shop or other area requiring isolation. Standard equipment on each panel includes: 2 pre-wired pumps Flat plate stainless steel heat exchanger Pre-wired Tekmar controls Isolation ball valves for both pumps and heat exchanger High performance micro-bubble air remover Brass unions on each heat exchanger inlet/outlet Manual fill/purge assembly on zone side Spring check valves for each zone 2, 0-50psi/60-320F gauges on load side Cat 5e connection M = 40 wide x 31.5 high x 12 deep Controls The pumps are pre-wired into the snowmelt control. Inter-panel connection to other Hydronex panels is achieved by plug and play Cat 5e cables, or are customizable for older applications. There are two automatic control options: Tekmar 361 with 501 relay control (compatible with all snow/ice sensors) Tekmar 665 (Tekmar 093 slab sensor must be ordered seperately) See accessories on page 111. Note: Limited availability until April Circuit HX-S Panel, 150 MBH HX, Watts Radiant Pumps, Tekmar 361 DHXS150-1WRT M 1 Circuit HX-S Panel, 250 MBH HX, Watts Radiant Pumps, Tekmar 361 DHXS250-1WRT M 1 Circuit HX-S Panel, 150 MBH HX, Taco Pumps, Tekmar 361 DHXS150-1TAT M 1 Circuit HX-S Panel, 250 MBH HX, Taco Pumps, Tekmar 361 DHXS250-1TAT M 1 Circuit HX-S Panel, 150 MBH HX, Bell & Gossett Pumps, Tekmar 361 DHXS150-1BGT M 1 Circuit HX-S Panel, 250 MBH HX, Bell & Gossett Pumps, Tekmar 361 DHXS250-1BGT M 1 Circuit HX-S Panel, 150 MBH HX, Watts Radiant Pumps, Tekmar 665 DHXS150-1WRT M 1 Circuit HX-S Panel, 250 MBH HX, Watts Radiant Pumps, Tekmar 665 DHXS250-1WRT Circuit HX-S Panel, 150 MBH HX, Taco Pumps, Tekmar 665 DHXS150-1TAT M 1 Circuit HX-S Panel, 250 MBH HX, Taco Pumps, Tekmar 665 DHXS250-1TAT M 1 Circuit HX-S Panel, 150 MBH HX, Bell & Gossett Pumps, Tekmar 665 DHXS150-1BGT M 1 Circuit HX-S Panel, 250 MBH HX, Bell & Gossett Pumps, Tekmar 665 DHXS250-1BGT M

15 103 ZZone Panels Basic Manifold These panels are the final distribution point for most radiant systems. This ZZone manifold package includes Watts Radiant s well known Stainless Steel manifolds, housed in a powder-coated steel enclosure with latching door. The enclosure can be mounted on a wall or recessed between studs. This basic package distributes heat delivered to it by a D Panel, or a field-installed zone pump. The ZZone is designed to serve one zone, and is available with 2 to 12 circuits. Each panel includes: 1 Stainless Steel manifold Supply and return manifold trunk ball valves Supply and return manifold mini temperature gauges Vent/purge assembly on supply manifold Flow meters (0-2gpm) on each circuit Balancing valves on each circuit White powder-coated steel enclosure with cover 2 Circuit Stainless SteelManifold ZZone M 3 Circuit Stainless Steel Manifold ZZone M 4 Circuit Stainless Steel Manifold ZZone M 5 Circuit Stainless Steel Manifold ZZone M 6 Circuit Stainless Steel Manifold ZZone L 7 Circuit Stainless Steel Manifold ZZone L 8 Circuit Stainless Steel Manifold ZZone L 9 Circuit Stainless SteelManifold ZZone L 10 Circuit Stainless SteelManifold ZZone L 11 Circuit Stainless SteelManifold ZZone L 12 Circuit Stainless SteelManifold ZZone L Please See Back Cover

16 104 ZZoneA Panels Basic Manifold with Valve Actuators The ZZoneA Panel allows you to serve two or more different zones from one manifold location. The panel is available with 2 to 12 circuits and comes with the individual circuit actuators and zone control all factory-wired; one actuator to one zone. Controlling more than one zone with a single thermostat is as easy as jumping the appropriate terminals in the control. See the Zone Valve Actuator Control instructions for further details. The ZZone package is normally supplied with water by a D Panel or field-installed zone pump, and is neatly housed in a powder-coated steel enclosure with latching door. The enclosure can be mounted on a wall or recessed between studs. Each ZZoneA panel includes: 1 Stainless Steel manifold Supply and return manifold trunk ball valves Supply and return manifold mini temperature gauges Vent/purge assembly on supply manifold Flow meters (0-2gpm) on each circuit Pre-wired zone relay control with 40 VA transformer Pre-wired circuit actuators on each circuit White powder-coated steel enclosure with cover 2 Circuit Stainless Steel Manifold with Actuators ZZone2A M 3 Circuit Stainless SteelManifold with Actuators ZZone3A M 4 Circuit Stainless SteelManifold with Actuators ZZone4A M 5 Circuit Stainless Steel Manifold with Actuators ZZone5A L 6 Circuit Stainless Steel Manifold with Actuators ZZone6A L 7 Circuit Stainless Steel Manifold with Actuators ZZone7A L 8 Circuit Stainless Steel Manifold with Actuators ZZone8A L 9 Circuit Stainless Steel Manifold with Actuators ZZone9A L 10 Circuit Stainless Steel Manifold with Actuators ZZone10A L 11 Circuit Stainless Steel Manifold with Actuators ZZone11A L 12 Circuit Stainless Steel Manifold with Actuators ZZone12A L Differential by-pass valve accessory. (see pg 111)

17 105 ZPumpZone Manifold with Zone Pump The ZPumpZone panel is used when the manifold does not have a dedicated supply pump in the boiler room. This manifold is neatly housed in a powder-coated steel enclosure with latching door. The enclosure can be mounted on a wall or recessed between studs. The ZPumpZone is designed to serve one zone, and is available with 2 to 7 circuits. Each panel includes: Watts Radiant zone pump Automatic air vent valve 1 Stainless Steel manifold Supply and return manifold trunk ball valves Supply and return manifold mini temperature gauges Vent/purge assembly on supply manifold Flow meters (0-2gpm) on each circuit Balancing valves on each circuit White powder-coated steel enclosure with cover 2 Circuit Stainless Steel Manifold with ZonePump ZPumpZone L 3 Circuit Stainless Steel Manifold with ZonePump ZPumpZone L 4 Circuit Stainless Steel Manifold with ZonePump ZPumpZone L 5 Circuit Stainless Steel Manifold with ZonePump ZPumpZone L 6 Circuit Stainless Steel Manifold with ZonePump ZPumpZone L 7 Circuit Stainless Steel Manifold with ZonePump ZPumpZone L

18 106 ZPumpZoneA Manifold with Zone Pump and Actuators The ZPumpZoneA Panel allows you to supply two or more different zones from one manifold location using the included zone pump. This panel would typically be used when the mechanical room does not have a dedicated pump to supply the heated water. It is neatly housed in a powder-coated steel enclosure with latching door. The enclosure can be mounted on a wall or recessed between studs. The ZPumpZoneA panel is available with 2 to 7 circuits and comes with the individual circuit actuators and zone control all factorywired; one actuator to one zone. Controlling more than one zone with a single thermostat is as easy as jumping the appropriate terminals in the control. See the Zone Valve Actuator Control instructions for further details. Each panel includes: Watts Radiant zone pump Automatic air vent valve 1 Stainless Steel manifold Supply and return manifold trunk ball valves Supply and return manifold mini temperature gauges Vent/purge assembly on supply manifold Flow meters (0-2gpm) on each circuit Pre-wired zone relay control with 40 VA transformer Pre-wired circuit actuators on each circuit White powder-coated steel enclosure with cover Differential by-pass valve accessory. (see pg 111) 2 Circuit Stainless Steel Manifold with ZonePump, Actuators ZPumpZone2A L 3 Circuit Stainless SteelManifold with ZonePump, Actuators ZPumpZone3A L 4 Circuit Stainless SteelManifold with ZonePump, Actuators ZPumpZone4A L 5 Circuit Stainless SteelManifold with ZonePump, Actuators ZPumpZone5A L 6 Circuit Stainless Steel Manifold with ZonePump, Actuators ZPumpZone6A L 7 Circuit Stainless Steel Manifold with ZonePump, Actuators ZPumpZone7A L

19 107 ZMixPumpZone Manifold with Zone Pump and Mix Valve The ZMixPumpZone panel has the ability to mix direct boiler water down to a field-adjustable F, and then pump it to a single zone made up of between 2 and 7 circuits. The whole package is neatly housed in a powder-coated steel enclosure with latching door. The enclosure can be mounted on a wall or recessed between studs. Each ZMixPumpZone panel includes: 1 field-adjustable, thermostatic mix valve Watts Radiant zone pump Automatic air vent valve 1 Stainless Steel manifold Supply and return manifold trunk ball valves Supply and return manifold mini temperature gauges Vent/purge assembly on supply manifold Flow meters (0-2gpm) on each circuit Balancing valves on each circuit White powder-coated steel enclosure with cover 2 Circuit Stainless Steel Manifold, ZonePump, Mix Valve ZMixPumpZone L 3 Circuit Stainless Steel Manifold, ZonePump, Mix Valve ZMixPumpZone L 4 Circuit Stainless Steel Manifold, ZonePump, Mix Valve ZMixPumpZone L 5 Circuit Stainless Steel Manifold, ZonePump, Mix Valve ZMixPumpZone L 6 Circuit Stainless Steel Manifold, ZonePump, Mix Valve ZMixPumpZone L 7 Circuit Stainless Steel Manifold, ZonePump, Mix Valve ZMixPumpZone L

20 108 ZMixPumpZoneA Manifold with Zone Pump/Mix Valve and Actuators The ZMixPumpZoneA is the ultimate in radiant distribution, allowing you to deliver thermostatically adjusted water to multiple zones using the included zone pump. This panel would typically be used when the mechanical room does not have a dedicated pump to supply the heated water, and is neatly housed in a powdercoated steel enclosure with latching door. The enclosure can be mounted on a wall or recessed between studs. The ZPumpZoneA panel is available with 2 to 7 circuits and comes with the individual circuit actuators and zone control all factory-wired; one actuator to one zone. Controlling more than one zone with a single thermostat is as easy as jumping the appropriate terminals in the control. See the Zone Valve Actuator Control instructions for further details. Each panel includes: 1 field-adjustable, thermostatic mix valve Watts Radiant zone pump Automatic air vent valve 1 Stainless Steel manifold Supply and return manifold trunk ball valves Supply and return manifold mini temperature gauges Vent/purge assembly on supply manifold Flow meters (0-2gpm) on each circuit Pre-wired zone relay control with 40 VA transformer Pre-wired circuit actuators on each circuit White powder-coated steel enclosure with cover Differential by-pass valve accessory. (see pg 111) 2 Circuit SS Manifold, Actuators, ZonePump, Mix Valve ZMixPumpZone2A L 3 Circuit SS Manifold, Actuators, ZonePump, Mix Valve ZMixPumpZone3A L 4 Circuit SS Manifold, Actuators, ZonePump, Mix Valve ZMixPumpZone4A L 5 Circuit SS Manifold, Actuators, ZonePump, Mix Valve ZMixPumpZone5A L 6 Circuit SS Manifold, Actuators, ZonePump, Mix Valve ZMixPumpZone6A L 7 Circuit SS Manifold, Actuators, ZonePump, Mix Valve ZMixPumpZone7A L

21 109 SPECIAL Special interest panels are a dedicated series designed to solve specific mechanical needs. These solutions may or may not directly incorporate other HydroNex panels. Condensing Boiler Panel This panel works with most modular condensing boilers. The master 1-1/2 stainless steel distribution manifolds supply up to 4gpm per circuit to radiators, fancoils, and/or remote radiant manifolds. A dedicated domestic hot water (DHW) priority control and pump comes with each panel. Essential functions, such as air removal, expansion tank attachment and re-filling are all taken care of on the panel. Each circuit on the master manifold is fitted with electro-thermal actuators. The pressure differential by-pass eliminates unwanted pressure-induced flow through any zone. The DHW priority shuts down the zone (space heat) pump when there is a call for domestic hot water. Standard equipment on the Modular Condensing Boiler Panel includes: Your choice of independently controlled Primary, Zone and DHW pumps, all pre-wired and tested Two 1 spring-check valves High performance micro-bubble air remover 0-50psi/60-320F gauge Service valves Pressure differential by-pass valve 1-1/2 Stainless Steel manifold with supply and return ball valves and temperature gauges Zone valve actuators, circuit flow meters (0-4gpm) and a vent/purge assembly on the supply Controls All 3 pumps are managed by the prewired control system. The zone valves are actuated by zone thermostats. Two or more circuits can be combined to serve larger zones, requiring more than 4 gpm. Note: Limited availability until April L = 52 wide x 31.5 high 4 Circuit Modular Condensing Boiler Panel, Watts Radiant Pumps, for Primary/DHW, for zones CB4WR M 5 Circuit Modular Condensing Boiler Panel, Watts Radiant Pumps, for Primary/DHW, for zones CB5WR L 6 Circuit Modular Condensing Boiler Panel, Watts Radiant Pumps, for Primary/DHW, for zones CB6WR L 8 Circuit Modular Condensing Boiler Panel, Watts Radiant Pumps, for Primary/DHW, for zones CB8WR L 4 Circuit Modular Condensing Boiler Panel, Taco Pumps, 0014 for Primary/DHW, 007 for zones CB4TA M 5 Circuit Modular Condensing Boiler Panel, Taco Pumps, 0014 for Primary/DHW, 007 for zones CB5TA L 6 Circuit Modular Condensing Boiler Panel, Taco Pumps, 0014 for Primary/DHW, 007 for zones CB6TA L 8 Circuit Modular Condensing Boiler Panel, Taco Pumps, 0014 for Primary/DHW, 0010 for zones CB8TA L 4 Circuit Modular Condensing Boiler Panel, Bell & Gossett Pumps, PL-36 for Primary/DHW, NRF-22 for zones CB4BGPL M 5 Circuit Modular Condensing Boiler Panel, Bell & Gossett Pumps, PL--36 for Primary/DHW, NRF-22 for zones CB5BGPL L 6 Circuit Modular Condensing Boiler Panel, Bell & Gossett Pumps, PL--36 for Primary/DHW, NRF-22 for zones CB6BGPL L 8 Circuit Modular Condensing Boiler Panel, Bell & Gossett Pumps, PL--36 for Primary/DHW, NRF-33 for zones CB8BGPL L

22 110 SPECIAL GeoThermal Panel Do you want the comfort of a radiant floor, but without adding carbon to the atmosphere? Use a ground source heat pump to power your hydronic radiant system. The HydroNex GeoThermal panel ties a water/water ground source heat pump to a radiant heating system. Patent Pending, and an industry first, this panel comes with a pre-wired outdoor reset control. This control allows the heat pump to operate at the lowest possible water outlet temperature, ensuring maximum efficiency and compressor life. As the temperature outside drops, the control automatically ramps up the outlet temperature from the heat pump. This innovative approach results in dramatic energy savings, compared to the use of standard set point controls, where the heat is almost always working harder than it needs to. The hydronic system must be carefully designed to not require use of water greater than 110 o F to 115 o F; the upper limit of most heat pumps. Use our RadiantWorks Software to verify maximum required system temperatures. This panel is designed to be used with standard hot water heater tanks for thermal buffer/storage. The buffer tanks eliminate short-cycling of the heat pump, extending compressor life. This also gives the building owner the manual option of having emergency heat capacity. Standard equipment on the GeoThermal panel includes: pre-wired pumps 1 Spring Check valves on supply and return to the heat pump Isolation ball valves for field-service of each pump Pre-wired Tekmar 256 outdoor reset control Cat5e cable connection for communication with other HydroNex panels Pre-wired system solenoid valve Temperature and pressure gauges White, powder-coated steel enclosure with cover Controls The heat pump will only run when the temperature of the buffer tanks falls below the weather responsive control setpoint. If there is no call for heat from the system, the solenoid valve will remain closed, directing hot water into the buffer tanks, until the required temperature is met. Whenever the radiant system calls for heat, the solenoid valve will open, automatically allowing hot water to flow from the tanks and/or from the heat pump. All controls come completely pre-wired and tested. The only field wiring required is the outdoor reset sensor, heat pump connection, and the plug and play Cat5e connection to the other HydroNex panels. This panel is designed to be installed with a PMan or PAuto HydroNex Primary Panel; and a DDirect Panel for load zone control. It is not a stand alone panel. It is suitable for use on up to six ton water/water geothermal heat pumps. See our design/installation manual or contact us for free design assistance. Note: Limited availability until April S=28 wide x 31.5 high x 12 deep M=40 wide x 31.5 high x 12 deep GeoThermal Panel for 1 unit, Watts Radiant Pump Geo1WR S GeoThermal Panel for 2 units, Watts Radiant Pumps Geo2WR M GeoThermal Panel for 3 units, Watts Radiant Pumps Geo3WR M

23 111 SPECIAL VIP Panel The VIP panel comes with an outdoor reset control that changes the system water temperature with variations in the outdoor conditions. The Tekmar 361 adjusts the speed of the variable-speed pump, regulating the flow of boiler water into your radiant loop. This is a simpler, more reliable and more cost-effective approach than the old motorized mixing valves. Each Panel is plumbed in 1.25 L copper, and is supplied with Watts quick-connect unions. Standard equipment for the VIP Panel includes: 1 variable-speed injection pump of your choice 1 Tekmar 361 variable-speed digital outdoor reset control 0-50psi/60-320F gauge Watts RPV valve for easy zone purging White, powder-coated steel enclosure Controls. This is a stand-alone, weather-responsive, variablespeed injection pump panel with a Tekmar 361 outdoor reset control, designed to be used with any properly field constructed primary/secondary mechanical room. Each VIP mechanical panel is equipped with a 1-1/4 main trunk with a 3/4 injection bridge. 28 wide x 31.5 tall x 12 deep VIP Variable-injection Mech. Rm. Panel, Watts Radiant Pump VIPWR S VIP Variable-injection Mech. Rm. Panel, Taco Pump VIPTA S VIP Variable-injection Mech. Rm. Panel, Bell & Gossett Pump VIPBGNRF S Accessories DESCRIPTION MODEL NUMBER ORDER NUMBER Replacement 504EXP Relay Box Replacement 506EXP Relay Box Replacement 501 Relay Box Replacement 4 Zone Master Valve Control Box P Replacement 6 Zone Master Valve Control Box P Replacement 4 Zone Slave Valve ControlBox P Replacement 6 Zone Slave Valve ControlBox P Replacement Thermal Actuator PZ Z Series Manifold Differential By-Pass Valve D Replacement Watts Radiant Circulator (flange) to be used with P, D, and S Series panels Replacement Watts Radiant Circulator (thread) to be used with Z Series panels Tekmar 093 Slab Sensor

24 112 Custom HydroControl and HydroSkid Mechanical Packages Watts Radiant s Custom HydroControl and HydroSkid mechanical packages are designed and manufactured to your project specificatons. Each comes complete from the factory fully tested and ready for installation. We use quality components and fittings to ensure trouble-free operation and longevity. HydroControls are priced at our factory, or by using RadiantWorks design software. Simply send us your project specifications and/or a RadiantWorks Zone List report, and we ll prepare a schematic and a quote. The next few pages show a range of typical packages. HydroControls and HydroSkids feature professional-grade components from companies you trust Watts, B & G, Taco, Grundfos, Tekmar, and other names you know. TYPICAL HYDRONIC COMPONENTS Primary Circulating Pump with isolation flanges. Secondary Circulating Pump(s) with isolation flanges. Injection Pump Mixing. Three-way Automatic Tempering Valve(s). In-line Automatic Micro-bubble Air Remover. Pressure Gauge. Temperature Gauge. Manual Fill and Air Purge Assembly. Automatic Pressure Regulating Valve with auto-fill option. Spring Check Valve(s) in zones. Secondary Purge Valves 2 way, full port. Miscellaneous Service Valves and Fittings as needed. Type L copper pipe and fittings. All HydroControls are mounted with uni-struts and vibration dampening clamps. Mechanical schematic showing how to make connections. TYPICAL ELECTRICAL COMPONENTS UL -Listed Electrical Service Box. Cube-type, Plug-in Relays. Wiring enclosed in flexible conduit. Fusetron with Manual Power Isolation Switch. 12 or 14 Gauge Solid Copper Wiring for high voltage connections. 18 Gauge Solid Copper Wiring for low voltage connections. Electrical schematic showing field connections to HydroControl.

25 113 Custom HydroControls for Permafrost Control Refrigerated Warehouse HydroControl efrigerated warehouses need supplemental eat to keep the earth below the warehouse om freezing, and heaving the floors. Many arieties of panels are offered, using gas or ectric boilers, or reclaiming refrigerant heat in rger installations. Panels feature automatic controls with round sensors, flow interruption alarms, w fluid alarms, pressure and temperature auges, and service valves. Panels are sized and customized to meet our project requirements using our time roven RadWorks software. Available for both arrier and non-barrier tubing. Custom HydroControls for Residential and Light Commercial Snowmelting Smaller package snowmelt systems offer the convenience of automatic controls that sense the presence of snow and only operate when necessary Perfect for smaller drives walks and entrances This panel features stainless steel brazed heat exchangers, automatic controls, high performance air vents, and pumps selected for your project needs. Call us for an engineered solution.

26 114 Custom HydroControls with Variable-speed Injection Pumps Primary/secondary HydroControls with weather-responsive injection control. These panels ensure the boilers have the correct fluid flow, regardless of how many zones are calling for heat. The weather-responsive design ensures the right water temperature is always running through the radiant floors. Look at the panel below for details. at the same temperature, but only run when a thermostat calls for heat. Many other options are available. The injection pump on the left is pumping water from a boiler (not shown) into the distribution zone on the right. As the weather gets colder, the injection pump on the left speeds up to put more heat into the radiant loop; as the weather gets warmer the pump slows down, putting less heat into the radiant loop. The seven pumps on the right are moving water through the individual radiant circuits and operate at a constant speed.

27 115 Custom HydroSkids for Commercial and Industrial Snowmelting Offer your clients the latest in automatic snowmelting systems. Most snowmelting systems cost less than 60 per square foot to operate. And if you re blading snow from pavers, stone, or decorative concrete, snowplowing will probably damage the surface. Yet another reason to melt snow away. Helipad Snow Removal System The blades from helicopters can fling chunks of ice hundreds of feet as they land and take off. This automatic system with redundant pumps and controls melts the snow from a one-acre helipad, even during the worst winter weather. Ski Resort Snowmelt System Snow removal is a costly problem for ski resorts, as well as for anyone where snow must be scooped up and trucked away. Ideal for resorts, urban shopping mall entrances, and hospital entrances.

28 116 Custom HydroSkids for Commercial and Industrial Radiant Heating Offer your commercial and industrial clients the comfort and energy saving benefits of radiant floor warming. Let the design team at Watts Radiant work with your local engineers to design customized system solutions for radiant heating, snowmelting, or permafrost protection. Watts Radiant offers complete design and fabrication of HydroSkids for almost any application. This early 21st-century skid-mounted panel is one of six designed and built for the Peabody Essex Museum. It will join the Peabody s permanent collection - in the mechanical room! Industrial equipment package for primary/secondary radiant heating. The primary panel (on left) has redundant primary pumps that circulate fluid between the boiler and the secondary distribution pumps. The secondary panel (on right) distributes heat to six different radiant zones in this large industrial manufacturing building in Nebraska. All pumps and controls are pre-wired and tested before shipping.

Hydronic Mechanical Panels

Hydronic Mechanical Panels Hydronic Assemblies Inc. 56 Horse Hill Rd Concord NH 2015-2016 Hydronic Mechanical Panels Contact 4805 Main St. Waitsfield, Vermont 05673 Phone : 802-583-5500 WWW.Houseneeds.com Hydronic Assemblies Inc.

More information

"Best Practices in Modern Hydronic Heating - THE DETAILS

Best Practices in Modern Hydronic Heating - THE DETAILS "Best Practices in Modern Hydronic Heating - THE DETAILS 190 supply water temperature (ºF) 170 150 130 110 90 fin-tube convector (RR=1.38) panel radiator (RR=1.0) thin slab rad. floor (RR=0.69) slab r

More information

Hydraulic Separation Moving Beyond Priamry / Secondary Piping...

Hydraulic Separation Moving Beyond Priamry / Secondary Piping... Hydraulic Separation Moving Beyond Priamry / Secondary Piping... load! #1 load! #2 load! #3 primary! circulator presented by: John Siegenthaler, P.E. Appropriate Designs Holland Patent, NY www.hydronicpros.com

More information

PRE-ASSEMBLED RADIANT CONTROL PANEL INSTALLATION MANUAL

PRE-ASSEMBLED RADIANT CONTROL PANEL INSTALLATION MANUAL FloorHeat PRE-ASSEMBLED RADIANT CONTROL PANEL INSTALLATION MANUAL Thank you for purchasing this radiant control panel assembly. Following are some important notes that will make the installation successful.

More information

Heat Transfer Products, Inc. 120 Braley Road East Freetown, MA The first totally integrated multiple boiler management control.

Heat Transfer Products, Inc. 120 Braley Road East Freetown, MA The first totally integrated multiple boiler management control. Heat Transfer Products, Inc. 120 Braley Road East Freetown, MA 02717 The first totally integrated multiple boiler management control. USING THIS MANUAL USING THIS MANUAL A. INSTALLATION SEQUENCE Follow

More information

ProRadiant Controls, Valves and Actuators

ProRadiant Controls, Valves and Actuators 214 Controls, Valves and Actuators Stock Controls, Valves and Actuators BASIC HEATING CONTROL Features: Modulating mixing valve control Supply temperature high limit Seasonal pump activation Boiler activation

More information

Circulators high efficiency ECM Circulators

Circulators high efficiency ECM Circulators Circulators high efficiency ECM Circulators Circulators high efficiency ECM Circulators Small ECM circulators now available in North America Grundfos Alpha: Provides constant and proportional differential

More information

Taco 00 Series Cartridge Circulators

Taco 00 Series Cartridge Circulators Water Circulation Pumps & Circulators Taco 00 Series Cartridge Circulators For over 70 years, Taco has led the industry with the highest quality circulators you can buy. Designed for a wide range of residential

More information

hydronics WHAT S WRONG WITH THIS SCHEMATIC?

hydronics WHAT S WRONG WITH THIS SCHEMATIC? BY JOHN SIEGENTHALER WHAT S WRONG WITH THIS SCHEMATIC? In the September/October 2005 issue of HPAC Magazine, methods to draw hydronic piping schematics were discussed. These drawings are an efficient way

More information

Allcan TM Installation Manual

Allcan TM Installation Manual Allcan TM Installation Manual NOTICE: READ THESE INSTRUCTIONS CAREFULLY. FAILURE TO FOLLOW INSTRUCTIONS VOIDS WARRANTY. Introduction: The PHP Allcan (USA patent pending) is a complete primary/secondary

More information

HPS Controls Ltd. Series 600 LFI / CFI Series 700 HFS Zone Control Stations. Heating and Radiant Floor Zone Control Stations

HPS Controls Ltd. Series 600 LFI / CFI Series 700 HFS Zone Control Stations. Heating and Radiant Floor Zone Control Stations Series 600 LFI / CFI Series 700 HFS Zone Control Stations Heating and Radiant Floor Zone Control Stations Installation Instructions Thank you for purchasing the finest in heating and radiant floor Control

More information

Modular Panel System for Radiant Floor Heating MICRO-BOILERS MODULAR PANEL SYSTEMS

Modular Panel System for Radiant Floor Heating MICRO-BOILERS MODULAR PANEL SYSTEMS Modular Panel System for Radiant Floor Heating MICRO-BOILERS MODULAR PANEL SYSTEMS Comprehensive technology, energy-saving performance, plus compact professional design make HydroShark s modular panel

More information

propanel Series Installation Manual

propanel Series Installation Manual propanel Series Installation Manual propanel Series Installation Manual is published by Uponor Wirsbo 5925 148th Street West Apple Valley, MN 55124 (952) 891-2000 2003 Uponor Wirsbo All rights reserved

More information

ECO1ZN3P, ECO2ZN4P ECO

ECO1ZN3P, ECO2ZN4P ECO WARNING HOT This product may have hot fluid circulating through it. DO NOT TOUCH! SOME UNION NUTS MAY BECOME LOOSE AND CONSEQUENTLY LEAK THROUGH TRANSPORTATION VIBRATION AND HANDLING. DO NOT OVERTIGHTEN

More information

Hydronic & HVAC Control Systems

Hydronic & HVAC Control Systems tekmar 218 Full Line Catalog Hydronic & HVAC Control Systems HVAC Multi-Staging Alternative Energy Zoning Snow Melting Setpoint tekmarcontrols.com tekmarcontrols.com Better Design, Better Control, Better

More information

Better Design, Better Control, Better Systems.

Better Design, Better Control, Better Systems. Product Catalog Better Design, Better Control, Better Systems. At tekmar Control Systems, we believe the indoor comfort of a building depends on the performance of its heating, ventilating & air conditioning

More information

- Essay Control Functions and Benefits

- Essay Control Functions and Benefits - Essay Control Functions and Benefits E 005 07/01 A hydronic heating control system performs many complex and important functions. Each of these functions provide benefits that make the system comfortable,

More information

- Data Brochure Universal Reset Module 423

- Data Brochure Universal Reset Module 423 - Data Brochure Universal Reset Module 423 D 423 08/07 1 Information Brochure Choose controls to match application Application Brochure Design your mechanical applications 2 3 Rough-in Wiring Rough-in

More information

- Data Brochure Universal Reset Module 422

- Data Brochure Universal Reset Module 422 - Data Brochure Universal Reset Module 422 D 422 08/07 1 Information Brochure Choose controls to match application Application Brochure Design your mechanical applications 2 3 Rough-in Wiring Rough-in

More information

NCB-E Combi-boilers. The first high efficiency condensing combi boilers that can do it all... for larger homes

NCB-E Combi-boilers. The first high efficiency condensing combi boilers that can do it all... for larger homes The Leader in Condensing Technology NCB-E Combi-boilers The first high efficiency condensing combi boilers that can do it all... for larger homes New NaviLink Wi-Fi remote control system... Available as

More information

union swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve

union swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve VENT APPENDIX A: PIPING SYMBOL LEGEND GENERIC COMPONENTS CALEFFI COMPONENTS circulator circulator w/ ThermoBloc union circulator w/ swing check spring loaded balancing balancing w/ gate check globe s purging

More information

Outdoor Reset Control Theory FULL versus PARTIAL reset

Outdoor Reset Control Theory FULL versus PARTIAL reset Outdoor Reset Control Theory FULL versus PARTIAL reset Conventional boilers must be protected against sustained operation at low temperatures. If not, they will be damaged by sustained flue gas condensation.

More information

NCB-E Combi-boilers. The first high efficiency condensing combi boilers that can do it all... for larger homes

NCB-E Combi-boilers. The first high efficiency condensing combi boilers that can do it all... for larger homes The Leader in Condensing Technology NCB-E Combi-boilers The first high efficiency condensing combi boilers that can do it all... for larger homes New NaviLink Wi-Fi remote control system... Available as

More information

The electrical wattage needed by the circulator is:

The electrical wattage needed by the circulator is: The electrical wattage needed by the circulator is: w e = 0.4344 f P n w/w A current-generation wet-rotor circulator has a maximum wire-towater efficiency in the range of 25 percent. If we put the data

More information

96% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR

96% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR 5:1 FIRING RATE MODULATION LESS THAN 20 ppm NOx DIRECT VENT FLEXIBILITY TO 100 FEET 96% AFUE

More information

Table of Contents. Installation, Operation, and Maintenance Manual V100 Series

Table of Contents. Installation, Operation, and Maintenance Manual V100 Series V101 EXPANSION TANK CONNECTION WARRANTY ON PUMPS VOID IF RUN DRY! CHECK VALVES INSTALLED IN ALL PUMPS WARNING HOT This product may have hot fluid circulating through it. DO NOT TOUCH! V10 EXPANSION TANK

More information

INSTALLATION MANUAL GEO-BOOST GROUND LOOP HEAT EXCHANGER

INSTALLATION MANUAL GEO-BOOST GROUND LOOP HEAT EXCHANGER INSTALLATION MANUAL GEO-BOOST GROUND LOOP HEAT EXCHANGER Build Equinox support@buildequinox.com (773)-492-1893 Rev 2.0-05/10/2018 Build Equinox 2018 The Geo-Boost system consists of the Geo-Boost heat

More information

- Data Brochure Universal Reset Control 364

- Data Brochure Universal Reset Control 364 70 7 8 9 - Data Brochure Universal Reset Control 364 D 364 07/01 The Universal Reset Control 364 is designed to maximize the comfort and efficiency provided by a hydronic heating system. The control automatically

More information

Product Instructions. Hydronic Mixing Block Version Wiring Terminal Block Pressure/Temperature Sensor Delivery Fitting (3) Display Screen

Product Instructions. Hydronic Mixing Block Version Wiring Terminal Block Pressure/Temperature Sensor Delivery Fitting (3) Display Screen Hydronic Mixing Block Version 1.104 The Hydronic Mixing Block is a mixing device and boiler control, with a built in circulator and system controller. The block can provide either a fixed or reset water

More information

Wood Boiler Plumbing Schematics

Wood Boiler Plumbing Schematics Wood Boiler Plumbing Schematics Solo Plus Froling FHG Solo Innova Excel Multi-Fuel 2 TABLE OF CONTENTS Section Page 1.0 Introduction..4 2.0 Plumbing Diagrams....5 2.1 Plumbing Example-Solo/Excel 1........5

More information

Applications and Piping Strategies for Condensing Boilers - Introduction

Applications and Piping Strategies for Condensing Boilers - Introduction Applications and Piping Strategies for Condensing Boilers - Introduction Foil 2, 10/2015 Viessmann Manufacturing Applications and Piping Strategies for Condensing Boilers Webinar Objectives: 1. Control

More information

Qualifies for up to $ 1500 Energy Tax Credit! CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ALL NEW, ADVANCED USER FEATURES

Qualifies for up to $ 1500 Energy Tax Credit! CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ALL NEW, ADVANCED USER FEATURES CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ALL NEW, ADVANCED USER FEATURES 5 FLOOR-STANDING AND 5 WALL-MOUNT MODELS FROM 50,000 TO 285,000 BTU/HR FIRING RATE MODULATION TO 5:1 LESS THAN 20 ppm NOx

More information

TECHNICAL. Series 18. Pump Packages

TECHNICAL. Series 18. Pump Packages TECHNICAL S Y S T E M S Series 18 Pump Packages Series 18 Pump Packages Standard Features Close-coupled, end-suction, centrifugal pumps Mounted and wired pump starters Hand-Off-Auto switch for each pump

More information

HPS Controls Ltd. Series 600 LFI / CFI Series 700 HFS Zone Control Stations. Heating and Radiant Floor Zone Control Stations

HPS Controls Ltd. Series 600 LFI / CFI Series 700 HFS Zone Control Stations. Heating and Radiant Floor Zone Control Stations Series 600 LFI / CFI Series 700 HFS Zone Control Stations Heating and Radiant Floor Zone Control Stations Installation Instructions Thank you for purchasing the finest in heating and radiant floor Control

More information

HVAC No. MFG Part No. Description Size Price

HVAC No. MFG Part No. Description Size Price Circulator Isolation Flanges and Valves Webstone 113460 113462 113464 113466 390608 390564 Flanged Isolation Valves 110-251F 110-252F 110-253F 110-254F SF-075T SF-100T Freedom Flange, Cast Iron Freedom

More information

INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE

INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE SPECIFICATIONS... 1 OVERVIEW... 2 PRECAUTIONS... 2 MOUNTING LOCATION... 2 CONNECTION TO BOILER PRIMARY PIPING:... 3 ELECTRICAL CONNECTION... 4 FLUSHING THE

More information

2.A MANIFOLD SHUNTS MINI SHUNTS

2.A MANIFOLD SHUNTS MINI SHUNTS 2.A MANIFOLD SHUNTS MINI SHUNTS ROTH HEATING SYSTEMS 2A. MANIFOLD SHUNTS Roth Manifold Shunts 4"/5.8cv and 1"/7.0cv Preassembled, manually adjusted, proportional temperature mixing station with built-in,

More information

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model BWXP OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER Electric Heater Company Base Model "BWXP" HUBBELL ELECTRIC HEATER COMPANY P.O. BOX 288 STRATFORD, CT 06615 PHONE: (203)

More information

HPS Controls Ltd. Series 100 LTV / CTV Zone Control Stations. Heating and Radiant Floor Zone Control Stations. Installation Instructions

HPS Controls Ltd. Series 100 LTV / CTV Zone Control Stations. Heating and Radiant Floor Zone Control Stations. Installation Instructions Series 100 LTV / CTV Zone Control Stations Heating and Radiant Floor Zone Control Stations Installation Instructions Thank you for purchasing the finest in heating and radiant floor Control Stations. We

More information

Thermostatic Radiator Valves (Caleffi)

Thermostatic Radiator Valves (Caleffi) 02/09/16 B46 Thermostatic Radiator Valves (Caleffi) Thermostatic Control Heads Thermostatic control head fits radiator valves Set point locking mechanism Range stop adjustment Built-in sensor with liquid-filled

More information

Tankless Electric Water Heater Available up to 54 KW in Single or Three Phase Voltages

Tankless Electric Water Heater Available up to 54 KW in Single or Three Phase Voltages Model HX/TX Tankless Tankless Electric Water Heater Available up to 54 KW in Single or Three Phase Voltages Features Heavy Duty Construction Constructed with high grade materials to ensure long operating

More information

Electro-HELPS XV ELECTRO-BOILER SPECIFICATIONS. A complete product line to fi t all your application needs. Made in USA

Electro-HELPS XV ELECTRO-BOILER SPECIFICATIONS. A complete product line to fi t all your application needs. Made in USA Electro-HELPS XV Made in USA ELECTRO-BOILER SPECIFICATIONS A complete product line to fi t all your application needs The Electro-Boiler has been heating America s homes and businesses since 980. We take

More information

Radiant Pipe Description

Radiant Pipe Description Radiant Pipe Item Description ATIPXOB4C10 ATIPXOB4C250 ATIPXOB4C5 ATI Radiant Pex 1/2" x 1000' O2 barrier ATI Radiant Pex 1/2" x 250' with O2 barrier ATI Radiant Pex 1/2" x 500' with O2 barrier MPX836

More information

Pivot Stove Hydronic Installation Guide

Pivot Stove Hydronic Installation Guide Pivot Stove Hydronic Installation Guide Install Location When installing the header tank - install directly above the appliance. There needs to be a continual rise between the appliance and the header

More information

Application Guide. Vitodens 100-W B1HA/B1KA Residential Boiler

Application Guide. Vitodens 100-W B1HA/B1KA Residential Boiler Application Guide Vitodens 100-W B1HA/B1KA Residential Boiler APPLICATION GUIDE The application examples contained in this document serve as a guideline only. These are not engineered drawings and are

More information

Instruction Sheet. Press & Hold: Item, to view settings, to test. 24 V ±10% 50/60 Hz 3 VA 120 V (ac) 5 A 1/6 hp pilot 240 VA 20 to 260 V (ac) 2 VA

Instruction Sheet. Press & Hold: Item, to view settings, to test. 24 V ±10% 50/60 Hz 3 VA 120 V (ac) 5 A 1/6 hp pilot 240 VA 20 to 260 V (ac) 2 VA Instruction Sheet PC2 1 Two Stage Reset & Control SUPERSEDES : 102-106, dated June 1, 2000 EFFECTIVE: March 1, 2004 Plant ID# 9300-1059 Item 102-106 The PC2-1 is a microprocessor-based control designed

More information

INSTALLATION MANUAL GEO-BOOST GROUND LOOP HEAT EXCHANGER

INSTALLATION MANUAL GEO-BOOST GROUND LOOP HEAT EXCHANGER 1103 N HIGH CROSS RD URBANA, IL 61802 1-773-492-1893 INSTALLATION MANUAL GEO-BOOST GROUND LOOP HEAT EXCHANGER REV 1.0 The Geo-Boost system consists of the Geo-Boost heat exchanger and a relay controller

More information

EB-M*-** Midsize Electro-Boiler BL509. EB-S-**/EB-WX-**-2 TS Standard Electro-Boiler BL506. EB-CX-** TS Commercial Electro-Boiler BL508

EB-M*-** Midsize Electro-Boiler BL509. EB-S-**/EB-WX-**-2 TS Standard Electro-Boiler BL506. EB-CX-** TS Commercial Electro-Boiler BL508 Electro-HELPS IX Boiler, Submittal Data Sheets These provide the mechanical technical details often required for architects/design engineers, shop drawings, etc. They are also useful in providing additional

More information

Hydronic Product & Application Catalog

Hydronic Product & Application Catalog Hydronic Product & Application Catalog Brazed Plate Heat Exchangers MJanuary 2005 for: Radiant Floor Heating Domestic Water Heating Snow Melt Swimming Pools Steam Close Approach High Pressure Systems Multi-Purpose

More information

- Data Brochure D 260. Boiler Control /09

- Data Brochure D 260. Boiler Control /09 - Data Brochure Boiler Control 260 D 260 03/09 The Boiler Control 260 is designed to control a single stage heat source in order to provide outdoor reset or Domestic Hot Water () operation. The control

More information

... Green Building Details

... Green Building Details Combining Solar HW with Radiant Floor using a Demand Water Heater back-up and a Tempering Tank with a line voltage three-way valve to prevent heating the solar storage with the gas DHW... A short list

More information

SAMPLE. added benefit of reduced operating costs during low demand periods, such as spring and fall.

SAMPLE. added benefit of reduced operating costs during low demand periods, such as spring and fall. Chapter 4 Variable-speed pumps. A variable-speed pump varies the flow rate by maintaining a constant pressure differential as zone valves open and close. A sensor measures the difference in pressure between

More information

- Data Brochure Boiler Control 274

- Data Brochure Boiler Control 274 - Data Brochure Boiler Control 274 274_D 03/17 The Boiler Control 274 operates up to four on/off boilers to provide outdoor reset operation, domestic hot water and setpoint operation with priority. When

More information

MAXIMIZING HYDRONIC SYSTEM DESIGN PART III

MAXIMIZING HYDRONIC SYSTEM DESIGN PART III MAXIMIZING HYDRONIC SYSTEM DESIGN PART III Presented by Cleaver Brooks Steve Connor & DCEs David Grassl June 21, 2017 TODAY S TOPICS Dispelling common myths about condensing boilers Supply water temperature

More information

Automatic Temperature Controller (ATC)

Automatic Temperature Controller (ATC) NEW FROM APOLLO...THE FIRST MULTIPLE-FIXTURE HI-LO MIXING VALVE THAT MEETS ASSE 1017 AND THE NEW ASSE 1069 STANDARD Only Apollo offers fast delivery on the first water temperature mixing assembly to meet

More information

Heat Link MECHANICAL ROOM IN A BOX. SSP Series. SS Manifold Pump Panel Installation, Operation, and Maintenance Manual. L6SSPxx000x-BMS SSPLR106T

Heat Link MECHANICAL ROOM IN A BOX. SSP Series. SS Manifold Pump Panel Installation, Operation, and Maintenance Manual. L6SSPxx000x-BMS SSPLR106T Heat Link SSP Series SS Manifold Pump Panel Manual NEUTRAL GROUND LIVE CAUTION 115 VOLTS ONLY SSPLR106T GROUND LIVE NEUTRAL CAUTION 115 VOLTS ONLY 120 40 60 60 80 100 C F 200 0 180 20 40 140 160 80 100

More information

Heat Pumps COMFORT NEED IT. When You

Heat Pumps COMFORT NEED IT. When You Heat Pumps COMFORT When You NEED IT COMFORT When You NEED IT SpacePak s Solstice heat pumps are air-to-water reverse cycle heat pumps that use the comfort of Hydronics as the primary source for both heating

More information

LOW TEMPERATURE HYDRONIC HEATING FOR COLD CLIMATES TRAVIS SMITH PRESIDENT T AND T MOUNTAIN BUILDERS INC

LOW TEMPERATURE HYDRONIC HEATING FOR COLD CLIMATES TRAVIS SMITH PRESIDENT T AND T MOUNTAIN BUILDERS INC LOW TEMPERATURE HYDRONIC HEATING FOR COLD CLIMATES TRAVIS SMITH PRESIDENT T AND T MOUNTAIN BUILDERS INC COLD CLIMATES REFERRING SPECIFICALLY TO CLIMATES ZONES 6 & 7 HYDRONIC HEATING USING A FLUID TO TRANSFER

More information

Heating Installation Guide published by

Heating Installation Guide published by Heating Installation Guide published by MrPEX Systems 2613 87th Court W. Northfield, MN 55057 800-716-3406 mrpexsystems.com mrpex@mrpexsystems.com 2014 MrPEX Systems All rights reserved Printed September

More information

GEOTHERMAL HYDRONIC CONTROL MODULE By TERRA-THERM, INC.

GEOTHERMAL HYDRONIC CONTROL MODULE By TERRA-THERM, INC. GEOTHERMAL HYDRONIC CONTROL MODULE By TERRA-THERM, INC. Physical Dimensions: 15-11/16 H x 11-13/16 W x 6-19/32 D M2-0152 HEAT PUMP HYDRONIC CONTROL MODULE With 2-stage heat, 2-stage cooling setpoint controls

More information

Combined Space and Water Heating: Making it Work

Combined Space and Water Heating: Making it Work Combined Space and Water Heating: Making it Work High Efficiency Heating in a Single Package Ben Schoenbauer, Center for Energy and Environment Jake McAlpine, Sustainable Resource Center February, 26 th,

More information

A Primary Concern by John Siegenthaler, P.E. October 1, 2005

A Primary Concern by John Siegenthaler, P.E. October 1, 2005 A Primary Concern by John Siegenthaler, P.E. October 1, 2005 When does a parallel primary loop make sense? It s hard to have a discussion on modern hydronic heating and not talk about primary/secondary

More information

Instruction Sheet X Pump Block (XPB)

Instruction Sheet X Pump Block (XPB) R Instruction Sheet X Pump Block (XPB) 02-202 SUPERSEDES: July, 200 EECTIVE: October, 200 Plant ID#: 00-3883 General WARNING SYMBOL: THIS SYMBOL INDICATES THE PRESENCE O HAZARDS WHICH CAN CAUSE SEVERE

More information

TOTAL SYSTEM EFFICIENCY: SYSTEM APPLICATIONS & DESIGNS. David Grassl PE Mechanical Engineer Principal

TOTAL SYSTEM EFFICIENCY: SYSTEM APPLICATIONS & DESIGNS. David Grassl PE Mechanical Engineer Principal TOTAL SYSTEM EFFICIENCY: SYSTEM APPLICATIONS & DESIGNS David Grassl PE Mechanical Engineer Principal Similar to traditional boiler systems, condensing boiler systems have many designs they can operate

More information

6 Zone 120/60/1vac 3A 24 VAC class 2 2 x 40 VA 2 x 5 amp fuses 1/6 hp, 120 VAC

6 Zone 120/60/1vac 3A 24 VAC class 2 2 x 40 VA 2 x 5 amp fuses 1/6 hp, 120 VAC Viega Zone Control Applications The Viega Zone Control is a wiring and switching center for individual and / or multi- room control. The Zone Control simplifies wiring between Thermostats and Powerheads.

More information

B-40/B-41 Modulating Temperature Controller

B-40/B-41 Modulating Temperature Controller INSTALLATION & OPERATING INSTRUCTIONS B-40/B-41 Modulating Temperature Controller For Raytherm Boilers & Water Heaters H2 514-4001 WH2 2100-4001 Catalog No. 5000.70 Effective: 12-21-11 Replaces: NEW P/N

More information

Solar & Hydronic Heating

Solar & Hydronic Heating TECHNICAL FEATURE This article was published in ASHRAE Journal, February 2012. Copyright 2012 American Society of ing, Refrigerating and Air-Conditioning Engineers, Inc. Posted at www.ashrae.org. This

More information

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F Temperature Control Units Water & Oil - F Portable Chillers Air & Water-Cooled - 7 F Central Chillers Air & Water-Cooled Packages & Modules - 7 F Pump Tank Stations Chilled or Tower Water - gallons Cooling

More information

- Data Brochure Mixing Control 360

- Data Brochure Mixing Control 360 - Data Brochure Mixing Control 360 D 360 03/09 The Mixing Control 360 is designed to control the supply water temperature to a hydronic system in order to provide outdoor reset or setpoint operation. The

More information

Boiler Demand Mix 1 Demand Mix 2 Demand DHW Demand Setpoint Demand

Boiler Demand Mix 1 Demand Mix 2 Demand DHW Demand Setpoint Demand Date Code - Data Brochure Universal Reset Control 374 D 374 10/03 The tekmar Universal Reset Control 374 is designed to maximize the comfort and effi ciency provided by a hydronic heating system. The control

More information

THE HEATING BOX. Training Manual. Model KD-HBO100 & KD-HBC100. * KD-HB100 (Open-Loop System) * KD-HBC100 (Close-Loop System)

THE HEATING BOX. Training Manual. Model KD-HBO100 & KD-HBC100. * KD-HB100 (Open-Loop System) * KD-HBC100 (Close-Loop System) THE HEATING BOX Training Manual Model KD-HBO100 & KD-HBC100 * KD-HB100 (Open-Loop System) * KD-HBC100 (Close-Loop System) Automatic Hot Water Management System A Combination System for Domestic Water and

More information

P r o d u c t C a t a l o g u e

P r o d u c t C a t a l o g u e Product Catalogue Tamas Hydronic Systems Inc. 4516-112th Avenue SE, Calgary, AB T2C 2K2 Telephone: (403)279-0020 Fax: (403)279-0747 Email: info@tamashydronic.com Web: tamashydronic.com Table of Contents

More information

INSTALLATION INSTRUCTIONS WINTER/SUMMER KIT

INSTALLATION INSTRUCTIONS WINTER/SUMMER KIT INSTALLATION INSTRUCTIONS WINTER/SUMMER KIT HYDRONIC HEATING WITH THE SOLAR WATER HEATER This winter/summer kit provides the necessary components for connections to a boiler. Through the proper installation

More information

Crown Boiler Company

Crown Boiler Company Crown Boiler Company 1 Phantom Boiler System Combi Kit Instruction Manual I Product Description This kit adds the ability to generate DHW, as well as heat, ( combi capability) to select Phantom models

More information

heat interface units A BOILER WITHOUT A FLAME

heat interface units A BOILER WITHOUT A FLAME A BOILER WITHOUT A FLAME heat interface units Communal Heat Networks A central boiler house will generate heat which is distributed through a network of pipe to each home or apartment in the building.

More information

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes). Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage

More information

OPERATION AND INSTALLATION UTILISATION ET INSTALLATION

OPERATION AND INSTALLATION UTILISATION ET INSTALLATION OPERATI AND INSTALLATI UTILISATI ET INSTALLATI Electric Modulating Micro-Boiler» HydroShark 7» HydroShark 0» HydroShark» HydroShark» HydroShark 9» HydroShark» HydroShark 9» HydroShark HydroShark 7 - HydroShark

More information

SECTION HYDRONIC PIPING AND SPECIALTIES

SECTION HYDRONIC PIPING AND SPECIALTIES SECTION 15511 HYDRONIC PIPING AND SPECIALTIES PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Pipe Materials. 2. Fittings. 3. Specialty Items. 4. Glycol Antifreeze Protection. 5. Process Cooling B.

More information

A. ASHRAE Handbook HVAC Applications, Snow Melting and Freeze Protection

A. ASHRAE Handbook HVAC Applications, Snow Melting and Freeze Protection PAGE 238318-1 SECTION 238318 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification sections,

More information

Daikin Altherma/Viessmann Integration Notes (used with schematics M1 thru M5)

Daikin Altherma/Viessmann Integration Notes (used with schematics M1 thru M5) March 15, 2011 Daikin Altherma/Viessmann Integration Notes (used with schematics M1 thru M5) Our Daikin Altherma project involves integrating an indoor unit (EKHBX054BA3VJU) with an existing domestic hot

More information

- Data Brochure Boiler Control 264e

- Data Brochure Boiler Control 264e - Data Brochure Boiler Control 264e D 264e 09/09 The kanmor Boiler Control 264e can control the supply water temperature from up to 4 on / off stages based on outdoor temperature, control for Domestic

More information

95% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS REMOTE CONNECT CAPABLE CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR

95% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS REMOTE CONNECT CAPABLE CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR CONDENSING RESIDENTIAL GAS BOILERS REMOTE CONNECT CAPABLE CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR 5:1 TURNDOWN RATIO LESS THAN 20 ppm NOx 95% AFUE Efficiency DIRECT VENT

More information

Installation & Operation Manual

Installation & Operation Manual tekmarnet 2 House Control 402 Installation & Operation Manual D 402 09/10 HVAC Systems Replaces: 01/10 Introduction The House Control 402 is designed to operate as part of a complete hydronic heating system

More information

Tankless On Demand Electric Water Heater

Tankless On Demand Electric Water Heater ECO FRIENDLY 98% EFFICIENT ENERGY & WATER SAVING Model MTX Tankless On Demand Electric Water Heater Available Up To 54 KW in Single or Three Phase Voltages Marine Approvals American Bureau of Shipping

More information

Innovative Boiler & Heat Exchanger Concepts

Innovative Boiler & Heat Exchanger Concepts www.wea-inc.com Wallace Eannace Associates Presents: Innovative Boiler & Heat Exchanger Concepts for Plumbing Applications Bob Barrett, CEM, LEED AP Sales Engineer Wallace Eannace Associates, Inc. www.wea-inc.com

More information

The Universal Reset Control 363 is a microprocessor based control designed to maximize the comfort and efficiency provided by a hydronic

The Universal Reset Control 363 is a microprocessor based control designed to maximize the comfort and efficiency provided by a hydronic R Vie Menu % % 1 2 Item F! WWS Vie Menu % % 1 2 Item F! WWS 70 LR 58233 E150539 Universal Reset Control 363 - Data Brochure D 363 12/08 The Universal Reset Control 363 is a microprocessor based control

More information

PROMAX XL MODELS CIRCULATING LOOP HEAT EXCHANGER MANUAL. Installation. Operation. Maintenance. Fill in the Rating Pate Information Here:

PROMAX XL MODELS CIRCULATING LOOP HEAT EXCHANGER MANUAL. Installation. Operation. Maintenance. Fill in the Rating Pate Information Here: CIRCULATING LOOP HEAT EXCHANGER MANUAL PROMAX XL MODELS Installation Operation Maintenance Fill in the Rating Pate Information Here: MODEL NO. SERIAL NO. INSTALLATION DATE Month Day Year CAUTION PLEASE

More information

THE ALL NEW COMBI BOILER

THE ALL NEW COMBI BOILER THE ALL NEW COMBI BOILER Noritz is excited to offer a new level of excellence to consumers with hydronic heating who wish to install one appliance to meet both domestic hot water and space heating needs.

More information

BB3000 Series. Application. Features. Injection Pump Control General Instructions

BB3000 Series. Application. Features. Injection Pump Control General Instructions BB3000 Series Injection Pump Control General Instructions Application The TAC Erie BB3000 Injection Pump Control with outdoor reset provides accurate control of the water temperature in the secondary (radiant)

More information

prestige Control Application Supplement - Type 5 MCBA WARNING

prestige Control Application Supplement - Type 5 MCBA WARNING prestige Control Application Supplement - Type 5 MCBA WARNING This document is intended to be used by a factory trained and qualified heating contractor or service technician only. Read all instructions

More information

Dual Mixing Application

Dual Mixing Application HBX MIXING APPICATION The CPU-000 configured as a Mixing Control allows for mixing of hitemp boiler (supply) water with lower temp system water, bringing several benefits to a hydronic design and installation.

More information

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job SERIES Commercial, Forced Draft, Hot Water or Steam Boiler Sizes from to,8 MBH output The right fit for any commercial job The Series is built to handle any installation - businesses, institutions, apartments,

More information

Installation & Operation Manual

Installation & Operation Manual 557_D tekmarnet Thermostat 557 09/14 Zoning Replaces: 09/13 Installation & Operation Manual Introduction The tekmarnet Thermostat 557 is a communicating touchscreen thermostat designed to operate either:

More information

Outdoor Reset IQ Option Card, p/n

Outdoor Reset IQ Option Card, p/n Outdoor Reset IQ Option Card, p/n 102723-01 Instruction Sheet CONTENTS Application... 1 General... 2 How it Works... 3 Installation.... 5 Wiring... 7 User Interface... 10 Using IQ Option Panel Display...

More information

BHSAPPMAN 08/00 USA. Applications Manual. Ecomatic / Logamatic Controls. Save These Instructions!

BHSAPPMAN 08/00 USA. Applications Manual. Ecomatic / Logamatic Controls. Save These Instructions! BHSAPPMAN 08/00 USA Applications Manual Ecomatic / Logamatic Controls Save These Instructions! TABLE OF CONTENTS 1 2 3 4 5 6 7 8 Introduction 1 Terms 2-4 Description of Wiring Terminals 5-7 Application

More information

GOLD Plus 30/40/60/80

GOLD Plus 30/40/60/80 PLUS Line Indirect-Fired Water Heaters Series 3 Manual Installation Startup Maintenance Parts PLUS 100/110/119 GOLD Plus 30/40/60/80 Plus 40/60/80 This manual must only be used by a qualified heating installer/service

More information

Tankless Electric Water Heater Available 3-27 kw in Single Phase Voltages

Tankless Electric Water Heater Available 3-27 kw in Single Phase Voltages Point-of-Use Tankless Tankless Electric Water Heater Available 3-27 kw in Single Phase Voltages Features Heavy Duty Construction Reliability Constructed with high grade materials to ensure long operating

More information

PRODUCT GUIDE EARTHLINKED TECHNOLOGIES GEOTHERMAL RENEWABLE ENERGY SYSTEMS SIMPLE. EFFICIENT. EFFECTIVE.

PRODUCT GUIDE EARTHLINKED TECHNOLOGIES GEOTHERMAL RENEWABLE ENERGY SYSTEMS SIMPLE. EFFICIENT. EFFECTIVE. PRODUCT GUIDE EARTHLINKED TECHNOLOGIES GEOTHERMAL RENEWABLE ENERGY SYSTEMS SIMPLE. EFFICIENT. EFFECTIVE. EarthLinked Geothermal Renewable Energy Systems are revolutionizing heating and cooling systems

More information

Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS. Technical Bulletin. Products that provide lasting solutions.

Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS. Technical Bulletin. Products that provide lasting solutions. Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS Technical Bulletin Products that provide lasting solutions. Krack Corporation has a long tradition of leadership and

More information

The Book of AERMEC NRL Sequence of Operation

The Book of AERMEC NRL Sequence of Operation The Book of AERMEC NRL Sequence of Operation Heating and cooling operation. 2 Sequence of operation Aermec air to water chiller/heat pump use Hydronic s in conjunction with refrigerant to provide heating

More information