1 50Low- and No-Cost Tips for Saving Energy INDUSTRIAL REFRIGERATION ENERGY EFFICIENCY
2 LOW- AND NO-COST SOLUTIONS THAT INCREASE ENERGY EFFICIENCY If you pay the power bill at an industrial cold storage or food distribution center, you know that refrigeration systems never stop CONSUMING ENERGY. As the largest electrical energy consumers in cold storage or distribution facilities, REFRIGERATION SYSTEMS should be a major savings target for spend-weary corporations. Yet, in today's economic climate where budgets for capital projects are small or non-existent, finding ways to reduce your energy spend can be a challenge. THE SOLUTION? Driving energy savings through low- or no-cost operations and maintenance activities. This ebook offers FIFTY of the best opportunities for CONTENTS 1 Evaporator Opportunities 2 Compressor Opportunities 3 Evaporative Condenser Opportunities 4 Control System Opportunities 5 System Opportunities 6 Systems Influencing Refrigeration Load achieving savings at little or no capital cost. SAFETY ALERT The improper execution of the activities outlined in this ebook could result in poor system performance, property damage, product quality issues, and serious bodily harm. Put safety first. Get qualified third-party contractors or certified refrigeration operators to implement the O&M actions in this guide, if your staff does not have the expertise LOW- AND NO-COST TIPS FOR SAVING ENERGY: REFRIGERATION SYSTEM
3 EVAPORATOR OPPORTUNITIES Cleaning Coils Evaporator coils should be regularly inspected and cleaned, particularly in docks or production areas where dirt, cardboard dust, rubber tire particulate, and other contaminants are common. Dirty coils may prevent a space from achieving temperature, force the system to run at lower suction pressure, or hinder evaporator fan cycling or variable frequency drive (VFD) control effectiveness. Dirty coils may not defrost well. Tune Overfeed Rates Systems with liquid recirculation (also called overfeed) design utilize hand expansion valves to meter liquid refrigerant at a 3:1 or 4:1 overfeed rate. If the valve is throttled too low, the coil will starve. If the valve is too open, the evaporator will brine. Adjust the valve to provide the maximum air temperature drop across the coil. Adjust Defrost Relief Regulators Hot gas defrost is often managed with a gas relief regulator at the coil exit to maintain a target pressure within the coil during the hot gas phase of the cycle. If this regulator is set too low, the defrost will be too long (due to low refrigerant temperature) and the regulator will freely allow gas to pass and load the engine room. If the regulator is set too high, this may force the system s minimum condensing pressure to be set higher, or cause steaming during defrost. A reasonable target is pounds per square inch gauge (psig) for ammonia systems. 4 Adjust Master Hot Gas Regulator Some systems utilize a master hot gas pressure regulator to maintain consistent pressure in the main hot gas header serving the coils. Pressure that is too high in the main header, results in excessive coil temperature and increased false loading in the engine room. The minimum system condensing pressure must be set at least 5-10 psig above the master regulator set point. A reasonable target pressure for the master regulator is psig for ammonia systems. A service provider should ensure coils are clean and clear of heavy frost before tuning LOW- AND NO-COST TIPS FOR SAVING ENERGY: REFRIGERATION SYSTEM
4 EVAPORATOR OPPORTUNITIES Remove Oil In most systems, any oil that migrates from the compressor eventually ends up in low-pressure receivers or evaporator coils. Oil in evaporator coils hinders cooling, and makes it extremely difficult to achieve a complete defrost at the bottom of the coil. Ice builds up and may eventually bridge to the defrost pan. It is important to remove this oil. Repair Valves and Regulators It is important that hot gas solenoids fully close and do not leak hot gas into the liquid or suction line. Also, regulators should fully close, as well as smoothly and consistently maintain target pressures. Remove Aging Ductwork Older system designs included wooden or metal ductwork to distribute air flow throughout a space. Unfortunately, this ductwork cannot be cleaned and may also prevent cleaning the evaporator coil fans (usually centrifugal) and coil surface. Modifying or removing this legacy ductwork can dramatically improve zone temperature management and system efficiency. Tuning Pressure Regulators Some evaporator coils or process heat exchangers (e.g., water or glycol chillers) are equipped with fixed or dual-pressure regulators. Ensure that the regulators are set for the greatest temperature difference allowed by system limitations (such as freeze protection, high humidity, etc.). Consult the original design engineer or contractor to determine the limits of the application. Differing frost patterns on valves during a given mode of operation indicates inefficiency LOW- AND NO-COST TIPS FOR SAVING ENERGY: REFRIGERATION SYSTEM
5 COMPRESSOR OPPORTUNITIES Solve Current Limiting / Forced Unloading Screw compressor microprocessor panels usually include settings to prevent overloading of the motor. If the panel sees motor current driving above nameplate or the service factor, the compressor will stop loading or even unload. This causes the compressor to lose efficiency by running in an unloaded condition. This may force the control system or operators to fire off another compressor to supply capacity. Use a clamp-on current meter to ensure that the current reading of the compressor microprocessor is correct. Also ensure that the current limiting parameters in the panel correctly match factory recommendations for stop-load or force-unload settings. It is not uncommon for current transformer (CT) multipliers to be in error or for the incorrect current limiting parameters to be entered into the controller. Most modern screw compressors have a microprocessor panel and control sensors, both of which must be calibrated correctly or else compressor performance can suffer. Ensure Economizer Operation Ensure that economizer ports function properly. The economizer pipe should be cold to the touch when the system is operating. Most economizers have a pressure regulator; ensure that the regulator is set to its factory recommended level. Most microprocessor panels will disable economizer function below a prescribed slide valve position (e.g., 75%) since economizer port gas is open to main suction pressure as the compressor unloads. Ensure that this setting is correct. It is not uncommon for a failure on the microprocessor board, or a failed economizer solenoid to prevent function altogether. Auto VI Feature Some screw compressors have automatic volume ratio controls. This matches the compressor internal compression ratio to the external system pressures to prevent over or under compression and loss of efficiency. Ensure the auto VI system is calibrated and operating correctly. If an external control system is managing compressor VI, ensure the system is calibrated and functioning properly LOW- AND NO-COST TIPS FOR SAVING ENERGY: REFRIGERATION SYSTEM
6 COMPRESSOR OPPORTUNITIES Manual VI Feature Other screw compressors may be equipped with a manually-adjustable volume ratio feature. Read the factory operating manual to determine the proper VI setting. Repair Shaft Seals Repair any leaking compressor shaft seals, ESPECIALLY systems operating in a vacuum. Air entering the system will impact condensing pressure, place a burden on the purging system, and introduce water into the refrigerant charge. Avoid Excessively Low Cut-Out If compressor cut-out suction pressure is set too low, a compressor may not turn off under extremely low-load conditions. The compressor will simply pull down to extremely low suction pressure and draw fully-unloaded power. If the compressor is set up this way on purpose (e.g., it has problems starting, see below), resolve this issue. Solve Starting Issues If a compressor cannot reliably start and stop, it may be tempting to operate it in an unloaded state to avoid the problem. Instead, resolve the issue that prevents reliable starting, whether the issue is with the motor starter or controls. If the concern is excessive motor restarts, consult with the compressor or motor manufacturer to determine the minimum allowable anti-recycle time to allow the compressor to restart promptly and avoid system disruption. Critical set points for compressors include economizers, pressure sensors, VFD settings, current transducers, and compression ration settings LOW- AND NO-COST TIPS FOR SAVING ENERGY: REFRIGERATION SYSTEM
7 EVAPORATIVE CONDENSER OPPORTUNITIES 16 Unplug Spray Nozzles Regularly inspect evaporative condenser spray nozzles to ensure nozzles are not plugged. 17 Water Treatment It is critical that water be treated for solids and biological content. It only takes a small amount of buildup on condenser tubes to dramatically reduce capacity (e.g., 1/16 of calcium carbonate can reduce condenser capacity by nearly 50%). Hold your water treatment contractor accountable for system performance. This will require regular inspection of condenser tubes. Good water treatment is critical to avoiding scaling on the tubes that causes a reduction in performance Water Pressure Although tempting, increased water pressure does not improve evaporative condenser performance. Most condensers are designed with modest water pressure at the header, perhaps 3-6 psi. Install a glycerin-filled 0-15 psig gauge in the condenser water distribution header and throttle the condenser pump to deliver the correct pressure. If substantial throttling is required, have the pump impeller trimmed to provide the proper amount of pressure for the application. Clean Strainers Regularly inspect and clean the condenser sump pump inlet strainer. A plugged strainer will reduce condenser capacity and waste pump energy. Adjust Sump Water Level Ensure that condenser sump float level is correct and that water level is not too low. Low water level can result in poor pump performance and water flow. Plugged Fill or Drift Eliminators Regularly clean fill material on induced draft condensers and drift eliminators on most condensers. Otherwise, reduced air flow will impact condenser performance. Address Non-Condensables Ensure the purger is working properly and that air is being eliminated from the condenser. Do this by measuring pressure and temperature at the condenser to verify the values correspond LOW- AND NO-COST TIPS FOR SAVING ENERGY: REFRIGERATION SYSTEM
8 EVAPORATIVE CONDENSER OPPORTUNITIES Tension Belts Check condenser fan belt tension to ensure there is no slip. Slip will reduce air flow and waste fan energy through the slip itself. Address Recirculation or Bad Environment Poor condenser configuration may result in warm, moist exhaust air from one condenser being drawn into a neighboring condenser. Poor rooftop layout may result in a boiler blow-down stack or process exhaust air stream placed near the inlet to a condenser. In all cases, address the issue to relocate, raise, or otherwise reduce moist or warm air entering the condenser. Correct Poor Drift Eliminator Strap Configuration To properly inspect condenser performance, hold-down straps must be loosened to allow drift eliminators to be removed. In some cases, these straps are configured so that they re difficult or impossible to remove. Reorient, or otherwise modify the strapping system to correct this issue. Wet vs. Dry Operation Evaporative condensers are inefficient when operated dry, particularly when ambient temperatures are above F. Ensure that condensers are properly winterized (sump heaters, heat trace, etc.) so they safely operate wet down to F ambient. Sump Heaters Ensure any electric sump heaters (often 10 kw, 20 kw or more) are functioning properly. Failed or incorrectly adjusted thermostats can result in inappropriate energy use by the heaters, and heating of the water that elevates discharge pressure. Proper maintenance helps avoid the top threats to condenser performance: non-condensable gases, scale on the tube bundle, and poor spray-water dispersion LOW- AND NO-COST TIPS FOR SAVING ENERGY: REFRIGERATION SYSTEM
9 CONTROL SYSTEM OPPORTUNITIES Zone or Process Temperatures Warehouse cooler or freezer temperatures should be set at an appropriate value as determined by product or customer requirements. Product, glycol, or other process temperatures should not be set lower than required. This may seem obvious, but systems are often set to maintain lower temperatures than necessary. Suction Pressure Raise system suction pressure to the highest allowable value (which is usually dictated by the worst-case temperature zone or process load). Note that this will affect evaporator fan cycling or VFD control, so some optimization may be in order. Condensing Pressure Operate the system at the lowest allowable minimum condensing pressure set point. If a system can be operated as low as psig (for ammonia) without problems, this is a reasonable target. Note that Fine-tuning control systems and using them to take advantage of demandresponse programs or varying utility rate schedules can be a considerable source of energy and cost savings. defrost, freezer floor heat, liquid injection performance, and compressor oil carryover are potential barriers to reduced minimum condensing pressure. Discuss possible limitations with the equipment manufacturer, refrigeration contractor, and system operators. Condenser Wet Bulb Approach If the control system offers a condenser wet bulb approach control feature, activate it and target an approach in the degree range. The optimum value may require experimentation. This feature ensures an appropriate balance of condenser capacity relative to refrigeration load and compressor operation. Evaporator Fan Cycling If the control system offers an evaporator fan cycling feature, activate it. In some cases, a swirl feature will operate the fans a minimum duty cycle to mix room air. Set up the swirl feature for the minimum required. If the control system has separate cut out and cut in set points for liquid solenoids and fans, energy savings is maximized when the cut in and cut out set point is the same for the solenoid and fan control LOW- AND NO-COST TIPS FOR SAVING ENERGY: REFRIGERATION SYSTEM
10 CONTROL SYSTEM OPPORTUNITIES 33 Condenser Staging Operate the most efficient condenser in the lead list first. Generally, the most efficient condensers are axial fan units with integral sumps. Centrifugals are less efficient, as are those with remote sump pumps or limitations to operation during frigid weather. Evaporative condensers are most efficient when wet with air flow at mid-range fan speeds. Avoid turning all system pumps on first, and then starting to add fans. Turn on a condenser pump, then the fans, then the next condenser pump, then fans, etc. The goal is wet with air movement for the greatest efficiency. 34 Defrost Schedule If the control system only offers a fixed defrost schedule, experiment with the number of defrosts per day to minimize defrost count. Do not let frost build up so much that it becomes difficult to achieve a full, clean defrost. There is no rule of thumb for defrost interval many coils can operate 8-16 hours or more between defrosts. In dry climates, it is not uncommon for evaporators to be defrosted only once or twice a week. Make sure the winterizing heat trace and sump heaters are functioning so the system performs well in frigid weather Defrost Initiation If the control system offers a liquid run-time feature or frost sensors, use this feature to initiate defrost only when necessary. Defrost Pump Down Ensure that all liquid is fully boiled out of the evaporator coil before hot gas is introduced. Watch a coil closely during a test pump down and measure fin temperature with a laser thermometer, or watch air temperature drop to determine when a coil is completely dry. This may require minutes for a frosted coil or one with VFD control operating at reduced speed. Defrost Hot Gas Duration Most evaporator coils should be able to clear all frost with minutes of hot gas. If you find a coil needing 45-60, or more minutes of hot gas to clear all frost, there is probably something wrong that should be addressed (e.g., hot gas regulator pressure, inadequate pump down, etc.). Transducer & Sensor Calibration Use an ice bath to calibrate key zone or process temperature sensors. Calibration pressure gauges ensure that the pressure transducers, used by a central control system, are properly calibrated. You may need to adjust offsets in the control system or even replace a failed pressure transducer. For compressors operating off their local microprocessor panels, calibrating control pressure transducers is critical (particularly suction) LOW- AND NO-COST TIPS FOR SAVING ENERGY: REFRIGERATION SYSTEM
11 CONTROL SYSTEM OPPORTUNITIES Poor Ambient Probe Location If a control system ambient temperature probe is located in direct sun, the probe will not read properly. This is particularly important when utilizing a condenser wet bulb strategy. Frigid Weather Condenser Strategies Many central control systems can turn off condenser water pumps (or drain condenser sumps) during frigid weather for freeze protection. It is important that these set points be set at reasonable values to minimize dry operation of the condensers. 41 Tune Internal VFD Parameters For evaporator and condenser fans, the most efficient VFD configuration is typically a low carrier frequency and a square or variable torque curve. There may also be energy-saving features or settings that can improve efficiency. The best method is to measure VFD input power with an appropriate power meter and experiment with these parameters to obtain the minimum power. All VFDs have internal parameters such as carrier frequency, torque curves, minimum and maximum speeds. It is vital that VFDs do exactly what the control system tells them to Optimum Evaporator VFD Strategies In general, evaporator fan VFDs can be operated with a minimum speed in the range of 40-50%. There is little additional savings from going slower. Limiting evaporator maximum speed to 90 or 95% can add savings with very little impact on net evaporator capacity. Liquid feed or pressure regulators should stay at full capacity until the fan VFDs are at minimum speed. Simultaneous speed control will save more energy than sequential ramping of speed when there are multiple coils in the zone. Optimum Compressor VFD Strategies Compressor minimum speed is dictated by compressor or motor limitations, typically in the range of 20-50%. Consult the manufacturer for proper settings. In nearly all cases, the compressor micro-processor manages the VFD and slide valve. Speed should be reduced first. Once at minimum speed, then the slide valve can be closed. Avoid simultaneous adjustment of speed and slide. Optimum Condenser VFD Strategies Implement pump and fan staging, minimum and maximum fan speeds to target the general strategy of wet with air at mid-range speeds. Mid-range can be defined as 30 to 80% speed. Once all condensers are online, fan speed can be allowed to rise to 100% LOW- AND NO-COST TIPS FOR SAVING ENERGY: REFRIGERATION SYSTEM
12 SYSTEM OPPORTUNITIES Purger Performance Ensure that the purger is operating properly. The purger counter should show a reasonable level of purging, but note that no system is perfect. There are control fuses, check valves or solenoids that can fail and prevent proper operation. Water in the System Regularly test the system refrigerant for excessive water content. Excessive water will change the properties of the refrigerant and substantially reduce system performance and efficiency. Pump Drum Tuning A gas pressure system (also called a Phillips or Pumper Drum System) has a number of critical pressure control regulators. Flash gas from a controlled-pressure receiver (CPR) or low pressure vessels should be properly routed to an appropriate suction (or economizer ports). Any hot gas supply regulators should be carefully adjusted to prevent false loading of the system. Liquid transfer units (LTUs) that utilize hot gas for dumping and liquid transfer should be carefully set up to avoid false loading of the system. Set CPR pressure to the lowest allowable value to maximize subcooling and prevent the CPR from acting as a barrier to minimum allowable condensing pressure. Repair Faulty or Leaking Float Drainers Liquid float drainers may be installed on main hot gas defrost headers, individual evaporator defrost relief, under-floor glycol heat exchangers, or other applications. If the float drainer is leaking hot gas, it will false load the system. Ensure that all liquid drainers are functioning properly. Water in a refrigeration system dilutes and impacts the boiling point of the system s ammonia. A water removal system or hybrid air/water purger should be installed to maximize efficiency LOW- AND NO-COST TIPS FOR SAVING ENERGY: REFRIGERATION SYSTEM
13 SYSTEMS INFLUENCING REFRIGERATION LOAD Door Performance Dock, cooler, or freezer door performance directly impacts refrigeration load and defrost requirements. Door seals, door defrost heaters, sensors, closing delays, and other characteristics are extremely important to minimizing refrigeration load. If re-circulatory air doors are used, proper control of air heaters (electric or hot gas), adjustment of air flow directional vanes, and clean return air screens or grates are key to efficiency. Lighting Performance Warehouse lighting controls, including motion sensors, bi-level control on high-intensity discharge lighting, manual or time clock controls all directly impact refrigeration load. Every watt of light fixture power ends up as refrigeration load in the space. Ensure that freezer under-floor heating systems are set to the minimum required ground temperature to prevent heaving. This should be carefully considered and implemented. Install motion controls and set sensor time delays to the minimum allowable delay for facility use patterns, safety, and manufacturer specifications LOW- AND NO-COST TIPS FOR SAVING ENERGY: REFRIGERATION SYSTEM
14 POINTS TO CONSIDER THINK ABOUT THE FOLLOWING AS YOU PURSUE LOW- AND NO-COST EFFICIENCY GAINS: Be willing to experiment while maintaining system stability and reliability. Every refrigeration system is unique and displays its own quirks and character. For this reason, each system must be poked, prodded, and otherwise forced to show its limitations and capabilities. It is important to remember that functional does not imply efficient. In most cases, a well-tuned and properly maintained system is more efficient. A small group of people dictates the energy use for the refrigeration system. These people are critical to reducing energy use. You must understand more than how a refrigeration system operates. It is important to understand what drives the energy use for each component or system in a way that allows you to make wise decisions regarding configuration, set points, and strategies. Consider a taking class that focuses on efficiency to improve your understanding and skill set. It is possible that there are misconceptions that have been passed on by other system operators, contractors, or vendors that are limiting efficiency of the system. Ask questions, do research, and talk to experts. Trust but verify. Design conditions are just that information used to select components and configure the system. Often, design conditions are not intended for day-to-day operation, particularly when pursuing efficiency gains. Avoid clinging to these values unless there is a strong, reasonable, or justified case. Some system inefficiencies or barriers can only be seen during certain seasons. For example, high condensing pressure may only manifest during the summer whereas limits to system minimum allowable condensing pressure may only be addressed during winter. If you utilize a third-party contractor to operate or maintain your system, the contractor must be involved in pursuit of energy efficiency. Implement processes, goals, or requirements to ensure alignment and accountability LOW- AND NO-COST TIPS FOR SAVING ENERGY: REFRIGERATION SYSTEM
15 Cascade Energy provides corporations and utilities with the industrial strength expertise needed to realize their energy efficiency potential. With a full complement of services and engineering know-how based on 20 years of hands-on experience, Cascade has a proven track record of reducing industrial energy consumption and costs. 20 YEARS Deep, hands-on technical expertise over a 20-year span. 2,000 PROJECTS Analyzed and implemented more than 2,000 energy efficiency projects. 350 SITES Monitor energy performance at over 350 industrial sites. 250 FACILITIES On-site tune-up and retrocommissioning at over 250 industrial facilities. INDUSTRY EXPERTISE Refrigerated storage Food processing and distribution Pulp and paper Oil and gas Steel and heavy industry High technology Water and wastewater Chemicals Manufacturing Agriculture SYSTEM EXPERTISE Refrigeration Compressed air Fans, pumps, blowers Manufacturing processes Controls and VFDs Chillers Cooling towers HVAC systems Thermal systems Lighting TALK TO CASCADE ENERGY TODAY! cascadeenergy.com energysensei.com info@cascadeenergy.com EBOOK REV 24-MAR-2013
ENERGY EFFICIENCY PROJECTS. NO-COST AND LOW-COST UPGRADES FOR YOUR FACILITY In partnership with: Refrigerating Engineers & Technicians Association
ENERGY EFFICIENCY PROJECTS NO-COST AND LOW-COST UPGRADES FOR YOUR FACILITY In partnership with: Refrigerating Engineers & Technicians Association INTRODUCTION Save Money, Improve Operations Today s refrigeration
More informationENERGY EFFICIENCY PROJECTS. NO-COST AND LOW-COST UPGRADES FOR YOUR FACILITY In partnership with: Refrigerating Engineers & Technicians Association
ENERGY EFFICIENCY PROJECTS NO-COST AND LOW-COST UPGRADES FOR YOUR FACILITY In partnership with: Refrigerating Engineers & Technicians Association INTRODUCTION Save Money, Improve Operations Today s refrigeration
More informationHow about Savings in Time, Money, Energy and Longer Life?
Chapter 17: The Value of Maintaining Evaporative Cooling Equipment 97 The Value 17 of Maintaining Evaporative Cooling Equipment 1. Cooling Tower Maintenance and Upgrades... What s in it for You? How about
More informationlmprovin Industrial Refrigeration -!nergy Efficiency
lmprovin Industrial Refrigeration -!nergy Efficiency R efvigeration systems consume a large portion of the total energy used in food processing and food storage industries. There are a number of simple
More informationPURGER INSTALLATION AND OPERATION BULLETIN PUR-SB17-02 SERVICE BULLETIN
VALVES VESSELS SYSTEMS CONTROLS PURGER INSTALLATION AND OPERATION BULLETIN PUR-SB17-02 SERVICE BULLETIN System drawings shown in this bulletin are for illustration purposes only. Refrigeration systems
More informationEmerging Technologies: VFDs for Condensers. Douglas T. Reindl Director, IRC University of Wisconsin-Madison. University of Wisconsin-Madison
Emerging Technologies: VFDs for Condensers Douglas T. Reindl Director, IRC University of Wisconsin-Madison University of Wisconsin-Madison 1 We ve looked at VFDs on Evaporators and compressors, what is
More informationInstallation, Operation, and Maintenance Information
Installation, Operation, and Maintenance Information Low Velocity Unit Coolers Bulletin No. IOM 110.3 Table of Contents Inspection... 2 Installation... 2 4 General... 2 Location... 2 Drain Line... 3 Refrigerant
More informationIntermediate Refrigeration Systems for Operators
Intermediate Refrigeration Systems for Operators A web-based course conducted by the www.irc.wisc.edu Intermediate Refrigeration Systems for Operators This class is designed to build upon and extend the
More information60Hz. R134a HXWC SERIES. 205 to 560 Tons. Products That Perform...By People Who Care WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS
R Products That Perform...By People Who Care FORM NO: MS0455A WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS R134a HXWC SERIES 205 to 560 Tons 60Hz INTRODUCTION Dunham-Bush's HXWC water cooled
More informationEnergy consumption storage facilities examined in ICE-E
Energy consumption storage facilities examined in ICE-E August 2012 Edited by Lars Reinholdt Danish Technological Institute = ICE-E Audit report 1 Contents EXECUTIVE SUMMARY 3 INTRODUCTION 4 THE ISSUES
More informationAir-Cooling Evaporators
Air-Cooling Evaporators Types of construction Circuit Configurations Methods of Refrigerant Feed Methods of Air Circulation Methods of Defrost Type of Construction Bare tube Finned Tube Plate-surface Bare
More informationGuidelines for Optimizing Drying and Blow-Off Operations
Experts in Technology Nozzles Control Analysis Fabrication Guidelines for Optimizing Drying and Blow-Off Operations Changing your approach can slash operating costs and increase efficiency Jon Barber,
More informationThomas J Kelly. Fundamentals of Refrigeration. Sr. Engineering Instructor Carrier Corporation. August 20, Page number: 1.
Thomas J Kelly Sr. Engineering Instructor Carrier Corporation August 20, 2003 1 SESSION OBJECTIVES At the conclusion of this session you should be able to: 1. Describe the basics principles of refrigeration
More informationFor an administrative fee of $9.97, you can get an un-locked, printable version of this book.
The System Evaluation Manual and Chiller Evaluation Manual have been revised and combined into this new book; the Air Conditioning and Refrigeration System Evaluation Guide. For an administrative fee of
More informationCondensing Unit Installation and Operating Instructions
Bulletin ACU_O&I 02 August 2016 Condensing Unit Installation and Operating Instructions ACU Air Cooled Condensers Table of Contents Section 1. General Information... 2 Section 2. Refrigeration Piping...
More informationEvaporative Cooling products
user manual Evaporative Cooling products OPERATION - MAINTENANCE Z0582995_A ISSUED 06/2017 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT general information Note Recold
More informationHVAC Maintenance for DIYers
HVAC Maintenance for DIYers Proper maintenance of your heating, ventilation, and air conditioning systems can significantly reduce costs, improve comfort levels, and extend equipment life. Despite all
More informationEnergy Management and Controls
As with the Chapter Review Tests and the Final Exam, the tests your understanding of the materials underlying the learning objectives. After you ve reviewed your answers to the Chapter Review Tests, try
More informationTrouble Shooting Guide RAA, 1-phase (D3627)
Trouble Shooting Guide RAA, 1-phase (D3627) Trouble Shooting Guide Problem Possible Cause Possible Remedy Unit does not start Unit does not cool No power to unit, breaker tripped Low voltage tripped Loose
More informationXSTREAM Valve System With A.R.M.E.D. Technology Service & Installation Instructions Page 1
Page 1 WHY should I install the XSTREAM Valve System? XDX is more efficient, saving on power consumption. Use of XDX system decreases defrost cycles. XDX maintains more consistent product temperatures,
More informationMYSTICOOL Max Valve System with Xstream and A.R.M.E.D. Technology Service & Installation Instructions Page 1
Page 1 WHY should I install the MYSTICOOL Max Valve System? XDX is more efficient, saving on power consumption. Use of XDX system decreases defrost cycles. XDX maintains more consistent product temperatures,
More informationTrouble Shooting Guide PAA, 1-phase (D3731)
Trouble Shooting Guide PAA, 1-phase (D3731) Trouble Shooting Guide Problem Possible Cause Possible Remedy Unit does not start Unit does not cool No power to unit, breaker tripped Low voltage tripped Loose
More informationThermoSaver TM Hot Gas Defrost System
PRODUCT DATA, APPLICATION & INSTALLATION GUIDE Supplement to Condensing Unit Installation and Maintenance Manual Bulletin K40-THERM-PDI-15 Part # 1069130 PRODUCT SUPPORT web: k-rp.com/ts email: mdcu-lgcu@k-rp.com
More informationCollege of Technological Studies Department of Power & Refrigeration Technology. Course Contents
College of Technological Studies Department of Power & Refrigeration Technology Course Contents Course Designation: Air Conditioning Control systems Course No. : 272 0463 Credit Hrs.: 3 Lecture Hrs.: 2
More informationAlfa Laval Wet Surface Air Coolers (WSAC ) FAQs
Alfa Laval Wet Surface Air Coolers (WSAC ) FAQs Q: How is the WSAC a closed-loop cooling system? A: The WSAC is a closed-loop cooling system because the process loop being cooled is inside the tube bundles
More informationCondensing Unit Installation and Operating Instructions
Bulletin WCU_O&I 01 June 2003 Condensing Unit Installation and Operating Instructions WCU Air Cooled Condensing Unit Table of Contents Section 1. Section 2. Section 3. Section 4. Section 5. Section 6.
More informationThermoSaver TM Hot Gas Defrost System
PRODUCT DATA, APPLICATION & INSTALLATION GUIDE Supplement to Condensing Unit Installation and Maintenance Manual Bulletin B40-THERM-PDI-14 1069132 ThermoSaver TM Hot Gas Defrost System For use on select
More informationWarning: 230V / 1ph / 50Hz V / 3ph / 50Hz. Remarks: Make sure that you have enough power. (See page 15 Cable table)
1 2 Warning: - Do not place your hand or any other objects into the air outlet and fan. It could damage the heat pump and cause injuries; - In case of any abnormality with the heat pump, cut off the power
More informationUNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions
UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions INSPECTION When the equipment is received, all items should be carefully checked against the bill
More informationTITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F
Temperature Control Units Water & Oil - F Portable Chillers Air & Water-Cooled - 7 F Central Chillers Air & Water-Cooled Packages & Modules - 7 F Pump Tank Stations Chilled or Tower Water - gallons Cooling
More informationThe Saturation process
SOUTH METROPOLITAN TAFE WA The Saturation process Dennis Kenworthy 8/5/2016 A student study guide to measuring and interpreting the saturation process of refrigeration and air-conditioning equipment System
More informationBRINE CIRCULATED ICE THERMAL STORAGE SYSTEM DESIGN - CASE ILLUSTRATION - Partial Ice Storage for Air Conditioning Application
1 BRINE CIRCULATED ICE THERMAL STORAGE SYSTEM DESIGN - CASE ILLUSTRATION - Partial Ice Storage for Air Conditioning Application By: T. S. Wan Date: Oct. 7, 1995 Copy Right 1995 by T. S. Wan All rights
More informationFull Range Systems. Mokon Troubleshooting Guide Model 311. Process/Water Loop. Problem Possible Cause Corrective Measure. Process pump will not start
Mokon Troubleshooting Guide Model 311 Process pump will not start Process pump shuts down during operation Pump seal leak Tank overflows or will not fill on systems with autofill option (water makeup valve)
More informationUser s Information Manual
48AJ,AK,AW,AY020-060 Single-Package Rooftop Gas Heating Units with COMFORTLINK Controls and Scroll Compressors User s Information Manual NOTE TO INSTALLER This manual should be left with the equipment
More informationMECHANICAL ENGINEERING ME.2017 FUNDAMENTAL OF REFRIGERATION AND AIR CONDITIONING. Sample Questions and Answers
MECHANICAL ENGINEERING ME.2017 FUNDAMENTAL OF REFRIGERATION AND AIR CONDITIONING Sample Questions and Answers CHAPTER 5 EVAPORATORS 1. What is Evaporator? Classify the various types of evaporator. Evaporator
More informationSECTION TESTING, ADJUSTING, AND BALANCING FOR HVAC
PART 1 GENERAL 1.01 SECTION INCLUDES SECTION 23 0593 TESTING, ADJUSTING, AND A. Testing, adjustment, and balancing of air systems. B. Testing, adjustment, and balancing of hydronic, steam, and refrigerating
More informationUSER'S MANUAL PGE Single Package Rooftop
USER'S MANUAL PGE Single Package Rooftop Gas Heating/Electric Cooling Units Sizes 036-150 3 to 12-1/2 Tons NOTE TO INSTALLER: This manual should be left with the equipment owner. WARNING: If the information
More informationService Step by Step Trouble-Shooting Check-List
WARNING: Only Data Aire trained technician or experience technicians should be working on Data Aire Equipment. Protect yourself at all times and work safe. Date: Dates at the job site: From: to Job#: Serial#:
More informationCPF PRODUCT DESCRIPTION
CPF 175 340 PRODUCT DESCRIPTION The CHICAGO PNEUMATIC CPF 175-340 compressor is a quiet, complete and ready-for-use unit for the production of compressed air in industrial applications. OVERVIEW The CHICAGO
More informationMidwest Industrial Initiative Webinar: Industrial Refrigeration
Midwest Industrial Initiative Webinar: Industrial Refrigeration Opportunities for Energy Efficiency and Cost Savings Thursday, June 6, 2013 www.kw-engineering.com Bryan Hackett, PE kw Engineering What
More information442 Chapter 16. Figure 16-5 Gas leak detection
BRORANE BRORANEBRORANEBRORANEBRORANEBRORANEBRORANEBRORANE 442 Chapter 16 Tur n e r BRORANE FUEL EBRORANEBRORANEBRORANEBRORANEBRORANE Figure 16-5 Gas leak detection is easy. This sensitive halide detector
More informationSERVICING PROCEDURE R-410A LEAK TEST EVACUATION CHARGING. Bard Manufacturing Company, Inc. Bryan, Ohio Manual Page 1 of 11
SERVICING PROCEDURE R-410A LEAK TEST EVACUATION CHARGING Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since 1914...Moving ahead, just as planned. Manual No.: 2100-479 Supersedes: NEW File: Volume
More informationTrouble Shooting Guide PWA, 3-phase (D10571)
Trouble Shooting Guide PWA, 3-phase (D10571) Trouble Shooting Guide Problem Possible Cause Possible Remedy Unit does not start Unit does not cool No power to unit, breaker tripped Low voltage Loose wire
More informationSECTION REFRIGERATION EQUIPMENT. A. Section Includes: Refrigeration equipment for insulated cold storage rooms including necessary accessories.
SECTION 15650 REFRIGERATION EQUIPMENT PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Refrigeration equipment for insulated cold storage rooms including necessary accessories. B. Related Section: 1. 11400
More informationDEFROSTING METHODS Adapted from material originally provided by Kenneth S. Franklin, C.M., Director of Service, Hussmann Corporation
EVAPORATOR DEFROSTING: WHEN AND WHY The refrigeration evaporator is a container that provides room for the evaporating refrigerant. The refrigerant receives heat by conduction through the walls of the
More informationRefrigeration Systems and Accessories
As with the Chapter Review Tests and the Final Exam, the tests your understanding of the materials underlying the learning objectives. After you ve reviewed your answers to the Chapter Review Tests, try
More informationTitle: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards
Date Description of Change Pages / Sections Modified ID 6/15/16 Entire document - mgl44 PART 1 - INTRODUCTION 1.1 PURPOSE A. This section is intended to define the general installation and minimum product
More informationTrouble Shooting Guide FAA, 3-phase (D3631)
Trouble Shooting Guide FAA, 3-phase (D3631) Trouble Shooting Guide Problem Possible Cause Possible Remedy Unit does not start Unit does not cool No power to unit, breaker tripped Low voltage tripped Loose
More informationEQUIPMENT PRE-STARTUP AND STARTUP CHECKLIST TEL NO: ORDER NO: CONTRACT NO:
Supersedes: (316) Form QTC4-CL2 (617) MODEL QTC4 EQUIPMENT PRE-STARTUP AND STARTUP CHECKLIST CUSTOMER: ADDRESS: PHONE: JOB NAME: LOCATION: CUSTOMER ORDER NO: TEL NO: ORDER NO: CONTRACT NO: CHILLER MODEL
More informationCWS AIR-CONDITIONERS
CWS AIR-CONDITIONERS MODUL & MODUL XL INSTALLATION, OPERATION AND MAINTENANCE MANUAL MODUL_GB_2007.doc page 1 of 28 10/04/07 CWS air-conditioners 1 - Installation CONTENTS 1 Installation 2 Commissioning
More informationJCseries EVAPORATIVE CONDENSER. engineering data
JCseries EVAPORATIVE CONDENSER engineering data Recold JC Series Evaporative Condenser Contents 2 Construction... 3 Schematic... 4 Engineering Data... 5 Selection Procedure... 6-9 Multi-Circuited Selection
More informationTable of Contents. Service Procedures. Service Procedures. Measuring Superheat (4) Measuring Subcooling (5) Airflow Calculation (6-8)
Table of Contents Refrigeration Cycle Service Procedures Measuring Superheat (4) Measuring Subcooling (5) Airflow Calculation (6-8) Solving Problems Identifying Low System Charge (9-11) Identifying High
More informationCONTENTS. B. System Design and Performance Requirements
15625 Water Chillers This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications or in notes
More informationAIR CONDITIONING. Carrier Corporation 2002 Cat. No
AIR CONDITIONING Carrier Corporation 2002 Cat. No. 020-016 1. This refresher course covers topics contained in the AIR CONDITIONING specialty section of the North American Technician Excellence (NATE)
More informationMODEL YVAA EQUIPMENT PRE-STARTUP AND STARTUP CHECKLIST CUSTOMER: LOCATION: ADDRESS: CUSTOMER ORDER NO: PHONE: JCI CONTRACT NO: JOB NAME:
Supersedes: 201.28-CL2 (817) Form 201.28-CL2 (1017) MODEL YVAA EQUIPMENT PRE-STARTUP AND STARTUP CHECKLIST CUSTOMER: LOCATION: ADDRESS: PHONE: JOB NAME: CUSTOMER ORDER NO: JCI CONTRACT NO: CHILLER MODEL
More informationWebinar: HVAC Claims Repair versus Replace Presenter: Curtis VanNess, General Manager HVAC Forensics Webinar Questions & Answers
Webinar: HVAC Claims Repair versus Replace Presenter: Curtis VanNess, General Manager HVAC Forensics Webinar Questions & Answers Q: Can you explain how a swamp cooler works and/or is different? A swamp
More informationKE2 EvaporatorEfficiency Theory of Operation
Theory T.1.1 June 011 TM thermsolutions ENTER BACK KE Therm Solutions, Advanced Energy Saving Technology for Commercial Refrigeration and AC Systems Page Table of Contents Basic Refrigeration System Evaporator
More informationSECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS
SECTION 15732 - PACKAGED ROOFTOP AIR CONDITIONING UNITS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Package roof top unit. B. Heat exchanger. C. Refrigeration components. D. Unit operating controls. E. Roof
More informationRECOMMENDED PROCEDURES FOR THIRD-PARTY PREVENTATIVE MAINTENANCE PROVIDERS
RECOMMENDED PROCEDURES FOR THIRD-PARTY PREVENTATIVE MAINTENANCE PROVIDERS 1 Contents Introduction... 3 Portfolio Energy Goals... 3 Purpose of This Document... 3 Gas Furnaces... 4 Electric Furnaces... 7
More informationMLC Air Cooled Chillers MLC-FC Free Cooling Chillers MLC-AD Adiabatic Chillers
MLC Air Cooled Chillers MLC-FC Free Cooling Chillers MLC-AD Adiabatic Chillers 60-500 Tons n Mission Critical Cooling n Central Plant Process Cooling n Specialized HVAC Cooling Systems COOLING SOLUTIONS
More informationChapter-8 Capacity Control of Refrigeration Systems
Chapter-8 Capacity Control of Refrigeration Systems Chapter-8 Capacity Control of Refrigeration Systems ၈.၁ Compressor Control Chiller Control and Chilled Water Plant Control Refrigeration system control
More informationINTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies
Pakistan s Largest Manufacturers of Air-Conditioners PACKAGE TYPE UNIT FOR MOBILE APPLICATIONS Provides Turnkey Projects Conceptual Planning to Commissioning of HVACR Projects THE LARGEST MANUFACTURER
More informationSPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module
SPECIFICATION GUIDE FLEXAIR Air-cooled packaged Rooftop unit Cooling only or Heat Pump Nominal cooling capacity: 85 to 234 kw Nominal heating capacity: 83 to 226 kw Possibility to add auxiliary heaters:
More informationTOTAL SYSTEM EFFICIENCY: SYSTEM APPLICATIONS & DESIGNS. David Grassl PE Mechanical Engineer Principal
TOTAL SYSTEM EFFICIENCY: SYSTEM APPLICATIONS & DESIGNS David Grassl PE Mechanical Engineer Principal Similar to traditional boiler systems, condensing boiler systems have many designs they can operate
More informationTECHNICAL. Series 18. Pump Packages
TECHNICAL S Y S T E M S Series 18 Pump Packages Series 18 Pump Packages Standard Features Close-coupled, end-suction, centrifugal pumps Mounted and wired pump starters Hand-Off-Auto switch for each pump
More informationAutomation and Energy Efficiency of Industrial Refrigeration Systems
Automation and Energy Efficiency of Industrial Refrigeration Systems E360 Forum Chicago, IL October 5, 2017 Mike Micak Director of Sales Logix Controls Introduction Management thinker Peter Drucker was
More informationElectrical Problems. Fuse(s) blow or circuit breaker trips. Does the unit use circuit breakers or fuses? Replace with correct fuse(s)
Electrical Problems Fuse(s) blow or circuit breaker trips Does the unit use circuit breakers or fuses? Fuse(s) Circuit breakers Are the fuses dual element time delay? Is the circuit breaker HACR rated?
More informationSECTION 5 COMMERCIAL REFRIGERATION UNIT 21 EVAPORATORS AND THE REFRIGERATION SYSTEM UNIT OBJECTIVES 3/22/2012 REFRIGERATION
SECTION 5 COMMERCIAL REFRIGERATION UNIT 21 EVAPORATORS AND THE REFRIGERATION SYSTEM UNIT OBJECTIVES After studying this unit, the reader should be able to Define high-, medium-, and low-temperature refrigeration.
More informationInterSeptor Centrifugal Separators Operating & Maintenance Manual
General Information: This manual was prepared to assist in the installation, operation, and maintenance of PEP ICS centrifugal separator systems. For immediate response to questions not covered in this
More informationYOUR BASIC REFRIGERAION SYSTEM SVASD MAY 26, 2011
YOUR BASIC REFRIGERAION SYSTEM SVASD MAY 26, 2011 Today s Goal Is to Understand the basic function of a refrigeration system Refrigeration The concept of refrigeration went unchanged for 2000+ years until
More informationINTRODUCTION HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O 4/19/2012
HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O INTRODUCTION HVAC systems or Heating, Ventilating and Air-Conditioning systems control the environment for people and equipment in our facilities.
More informationBLAST CHILLER / SHOCK FREEZER MODEL AP3BCF30-1
REV. D Cooler is Better! TM USER S MANUAL BLAST CHILLER / SHOCK FREEZER MODEL AP3BCF30-1 American Panel Corporation 5800 S.E. 78th Street, Ocala, Florida 34472-3412 Phone: (352) 245-7055 Fax: (352) 245-0726
More informationCPC PRODUCT DESCRIPTION
CPC 40 60 PRODUCT DESCRIPTION The CHICAGO PNEUMATIC CPC 40-60 compressor is a quiet, complete and readyfor-use unit for the production of compressed air in industrial applications. OVERVIEW The CHICAGO
More informationHEATING AND VENTILATION
SECTION 14-102.04 14-102.04/ 1 2007OC19 DESCRIPTION The heating, ventilation and air conditioning (HVAC) system is designed to optimize passenger comfort. The system regulates interior vehicle atmosphere,
More information"This is only the scope of work for the project. For more information, interested parties should contact Procurement at
"This is only the scope of work for the project. For more information, interested parties should contact Procurement at purchasing@stpgov.org to ensure receipt of a full bid package, to be listed as a
More informationBASIL 6000 TUNNEL CAGE WASHER
BASIL 6000 TUNNEL CAGE WASHER APPLICATION For thorough, efficient cleaning of cages, debris pans, bottles, feeder bowls, and miscellaneous items used in the care of laboratory animals. DESCRIPTION The
More informationChecking the Charge on a Heat Pump in the Winter
Checking the Charge on a Heat Pump in the Winter When you ask many people nowadays how to check the charge on a heat pump during low outdoor temps they will say that you need to weigh in and weigh out
More informationBuildingName The Description of the Project P DOCUMENTS
ARCHITECTURE, ENGINEERING AND CONSTRUCTION P00000000 0000 DOCUMENTS ARCHITECTURE & ENGINEERING 326 East Hoover, Mail Stop B Ann Arbor, MI 48109-1002 Phone: 734-764-3414 Fax: 734-936-3334 SPECIFICATION
More informationBASE LEVEL AUDIT REQUIREMENTS REFRIGERATION SYSTEMS 1. SITE DATA COLLECTION. Business Name. Site physical address (Street, Suburb, City)
BASE LEVEL AUDIT REQUIREMENTS REFRIGERATION SYSTEMS 1. SITE DATA COLLECTION Business Name Site physical address (Street, Suburb, City) Nature of site / business operation Electricity Supplier Power factor
More informationOperation & Maintenance
Ice Bear 30 Unit Operation & Maintenance for models: IB30A-521 IB30A-523 IB30A-543 through SN xxxx10130 Phone: (877) 542-3232 Fax: (970) 545-3634 Email: productservices@ice-energy.com www.ice-energy.com
More informationCPVS PRODUCT DESCRIPTION
CPVS 20 30 PRODUCT DESCRIPTION The CHICAGO PNEUMATIC CPVS 20-30 compressor is a quiet, complete and ready-for-use unit for the production of compressed air for light and medium industrial applications.
More informationSamsung EHS Heat Pump Test
Samsung EHS Heat Pump Test The following questionnaire is designed for installers who have experience with heat pumps, are currently MCS accredited, and who want to fast track their Samsung accreditation
More informationZD Tunnel Inline Cleaning Systems suginocorp.com Zippel GmbH
The ZD Series is our innovative response to the increasing diversity of parts requiring conveyor, chain, or fixtured in-line washing systems. Zippel through-feed cleaning machines can be custom-fit to
More informationMODELS LIST. Nominal Capacity RT
1. MODELS LIST. NOMENCLATURE 3. FEATURES 4. PRODUCT DATA 5. PERFORMANCE CORRECTION 6. ANTIFREEZE 7. INSTALLATION 8. ELECTRICAL DATA 9. SCHEMATIC WIRING DIAGRAM 10.MICROPROCESSOR CONTROLLER 11.APPLICATION
More informationPreventative Maintenance Tables
Preventative Maintenance Tables Table of Contents I. Table : Gas Fired Domestic Hot Water Heater II. III. IV. Table : Circulating Pump Table : Convectors Table 4: Grille and Diffusors V. Table 5: Unit
More informationRetrocommissioning Findings Summary: Building X #1 Priority: Major Comfort/Control Problems
IMPORTANT NOTICE: This sample document is provided for instructional purposes only. CCC is not rendering advice concerning any commission project or practices. This document is neither approved nor intended
More informationprecision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs
next generation C precision controlled industrial process chillers cooling capacity: 6824 -,255,668 BTU /hr (0.6-04.6 tons) cooling capacity: 6,824 -,254,303 BTU/hr (0.6-04.5 tons) precision controlled
More informationTuning up ventilation systems
MULTI-UNIT RESIDENTIAL BUILDINGS Tune-Ups for Energy and Water Efficiency This document is a tool to help reduce energy and water costs and improve comfort in a high-rise residential building through low-cost
More informationContour TM Screw Compressors
Contour TM Screw Compressors Semi-Hermetic Compact Operating Instruction SCH1 High Temp Compressors Form No. 99-77 1. Introduction This series of semi-hermetic compact screw compressors is designed for
More informationREFRIGERATION EQUIPMENT SCOPE - QUESTIONNAIRE
REFRIGERATION EQUIPMENT SCOPE - QUESTIONNAIRE Please provide the following information to receive a no-cost estimate of how much money our control system could save your facility and to assist us in preparing
More informationOWNER S MANUAL. Vintage Classic HEAT COOL models. Proudly Made in the USA
OWNER S MANUAL Vintage Classic HEAT COOL models Proudly Made in the USA support@aquacomfort.com www.aquacomfort.com/service-and-support 888-475-7443 Manufacturing High Quality, High Efficiency Heat Pump
More informationRDT Refrigeration Book
RDT Refrigeration Book Indoor / Outdoor Air-Cooled Systems Indoor Air-Cooled Systems 1. Shorter line runs. 2. Systems located off roof or dock space. 3. Weather covers are not required (saves cost). 4.
More informationSWIMMING POOL & SPA HEAT PUMPS OWNERS OPERATIONAL MANUAL
SWIMMING POOL & SPA HEAT PUMPS OWNERS OPERATIONAL MANUAL MODEL AT105 AT115 AT130 with Titanium Heat Exchanger 2213 Andrea Lane Ft. Myers FL 33912 888-297-3826 941-482-0606 www.aquathermheatpumps.com DIGITAL
More informationCalhoon MEBA Engineering School. Study Guide for Proficiency Testing Refrigeration
Calhoon MEBA Engineering School Study Guide for Proficiency Testing Refrigeration 1. To prevent an injury when working with refrigerants, what safety precautions are necessary? 2. When halogens are in
More informationYCIV Hz & Hz
YCIV 0590-1500 50Hz & 0157-0397 60Hz Start-up Checklist SERVICE POLICY & PROCEDURES Supersedes: Nothing Form 201.23-CL1 (309) Commissioning PREPARATION Commissioning of this unit should only be carried
More informationSECTION CENTRIFUGAL WATER CHILLERS Vibration Isolation Pumping Equipment (HVAC) Induced Draft Cooling Tower
SECTION 15682 CENTRIFUGAL WATER CHILLERS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 15240 - Vibration Isolation. 2. 15540 - Pumping Equipment (HVAC) 3. 15711 - Induced Draft Cooling Tower B. Removal
More informationOwner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350
Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350 Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others
More informationDaikin Direct Expansion (DX) Cooling Coils
Installation and Maintenance Manual IM 902 Daikin Direct Expansion (DX) Cooling Coils Group: Applied Air Part Number: IM 902 Date: February 2008 Types EN, EF, ER, EJ, EK 2008 Daikin Applied Contents Introduction...
More informationOIL COOLER INSTRUCTION HANDBOOK
OIL COOLER INSTRUCTION HANDBOOK INDEX 1. GENERALITY 2 1.1 OPERATING RANGE 1.2 IMPORTANT 2. INSTALLATION 3 2.1 TRANSPORTATION 2.2 INSTALLATION LOCATION 2.3 PIPING 2.4 WIRING (see the electrical diagram
More informationOWNER S MANUAL VMH 09/12/18/24
OWNER S MANUAL VMH 09/12/18/24 Version C Inverter Single Zone Ductless Mini-Split Heat Pump Heat Controller, Inc. 1900 Wellworth Ave. Jackson, MI 49203 (517)787-2100 www.heatcontroller.com VMH Inverter
More information