KUDOS. Instruction leaflet

Size: px
Start display at page:

Download "KUDOS. Instruction leaflet"

Transcription

1 KUDOS Instruction leaflet

2 KUDOS RAGE CETRIFUGA EXTRACTOR FAS Suitable for bathroom, kitchen and utility room applications Thank you for placing your confidence in EnviroVent by buying this product. It has been manufactured in accordance with current technical safety regulations, production and quality standards as laid down by the international Quality Standard ISO Please read this instruction booklet carefully before installing or operating the product. It contains important information on personal and user safety measures to be followed whilst installing, using and carrying out maintenance work on the equipment. Once the product has been installed, please pass this booklet to the end user. Check that the product is in perfect condition whilst unpacking. Any fault or damage caused in origin is covered by the EnviroVent guarantee. Please make sure that the product corresponds to the one you have ordered and that the details on the instruction label fulfil your requirements. IMPORTAT: BE SURE TO HAVE READ AD UDERSTOOD THESE ISTRUCTIOS BEFORE BEGIIG THE ISTAATIO PROCESS SAFETY AD RECOMMEDATIOS All wiring must comply with Building Regulations and the current I.E.E. Wiring Regulations (BS7671) or the equivalent standards for your country. The final installation should be examined and tested by a competent person. This fan is IP44 rated. Do not install near sources of heat in excess of 40 C. It is recommended that a flexible cable is used to connect the fan connector terminals Position away from any source of water spray from a bath or shower. Do not site in a shower enclosure. Position the fan at the furthest distance from the main source of air replacement in the room in order to achieve maximum airflow performance. Ducted Applications. In circumstances where an excessive amount of moisture is present in the air, then a condensation trap will need to be installed in the exhaust duct. Horizontal ducts should fall away from the fan unit. Ducts passing through an unheated roof void should be insulated. This appliance is not intended for use by young children or infirm persons unless they have been adequately supervised by a responsible person to ensure that they can use the appliance safely. Young children should be supervised to ensure that they do not play with the appliance.

3 ISTAATIO: KUDOS Fig Fig.1B Fig.2A Fig.2B

4 A B Fig.3 Fig.4 EBB- KUDOS- S S A B Fig.5A A B Fig.5B A B Fig.6A C A B Fig.6B REB

5 EBB- KUDOS- T T S Fig.7A S Fig.7B EBB- KUDOS- HT HT S Fig.8A S Fig.8B 30 A T(min.) T(min.) HR(%) S S Fig.9A Fig.9B

6 KUDOS RAGE CETRIFUGA EXTRACTOR FAS Suitable for bathroom, kitchen and utility room applications DESCRIPTIO Suitable for both ceiling and wall installation, the KUDOS fans can be either surface or recessed-mounted in a vertical or horizontal plane. The KUDOS 100 is ideally suited for WC and bathroom ventilation, the 170 for utility rooms and the 250 for kitchen ventilation. A. ISTAATIO IMPORTAT: ESURE THAT THE MAIS SUPPY IS SWITCHED OFF BEFORE MAKIG EECTRICA COECTIOS. Figure 1A: 1 - Front cover 2 - Fan body 3 - Front cover clip 4 - Base frame 5 - Terminal block flap 6 - Slots 7 - Retainers 8 - Guide vane 9 - Spigot assembly To ensure the extract fan works most efficiently: Do not use ducting with a diameter of less than 100mm If flexible ducting is use, stretch it as taught as possible. Do not fix elbow bends directly to the spigot assembly. Elbow bends should have a radius as large as possible. Panel Installation Surface Mounting (Fig. 2A) 1. Cut a Ø105mm hole through the panel, ensuring sufficient space for the fan to be installed. 2. Fig. 1B - By pushing the clip using a small screwdriver pull the front cover (1) away from the fan body (2). 3. The fan body (2) is secured to the base frame (4) by 4 screws. Take out each screw from the four corners (6) to dismantle and release the base frame. 4. Screw the base frame (4) to the panel using appropriate fixtures ensuring that the opening for the spigot lines up correctly with the hole made. 5. Take out the screw that secures the terminal block flap (5) to the fan body (2). 6. Attach the ducting to the spigot (9). 7. Feed the cable through the hole in the terminal block (Fig. 3). 8. Reassemble the fan body (2) to the base frame (4) and secure with 4 screws 9. Follow instructions for Electrical Connections and Wiring in B.

7 10. Close the terminal block flap and secure with the screw. 11. By pressing the upper and lower clips, fit the front cover back onto the fan body. 12. Switch the mains power supply on and check that the fan is working correctly. Panel Installation Recess Mounting (Fig. 2B) 1. Using the template supplied, mark out and cut a hole in the panel. Read the instructions on the template sheet carefully. 2. Fig. 1B - By pushing the clip using a small screwdriver pull the front cover (1) away from the fan body (2). 3. The fan body (2) is secured to the base frame (4) by 4 screws. Take out each screw from the four corners (6) to dismantle and release the base frame. 4. Take out the screw that secures the terminal block flap (5) to the fan body (2). 5. Fig For side exit installations, the spigot assembly (9) can be repositioned. To do this, remove the spigot assembly (9) from the fan body (2). Rip off the guide vane (8) from the fan body and reattach the spigot in a side orientation in the desired direction. 6. Attach the ducting to the spigot (9). 7. Feed the cable through the hole in the terminal block (Fig. 3) 8. Using appropriate fixtures, screw the fan body (2) into the hole in the panel. 9. Follow instructions for Electrical Connections and Wiring in B. 10. Close the terminal block flap and secure with the screw. 11. By pressing the upper and lower clips, fit the front cover back onto the fan body. 12. Switch the mains power supply on and check that the fan is working correctly. Wall Installation Surface Mounting Using 100mm EnviroVent Wall Kit. 1. Drill a Ø115mm hole through the wall, ensuring sufficient space for the fan to be installed. 2. Insert the wall sleeve with the wider diameter sleeve facing the room side and cement both ends in place, flush with the wall. The wall sleeve must be angled downwards to drain any condensation to outside. 3. To fix the outside grille, use the back plate as a template and mark the fixing holes on the wall. Drill and plug the wall to fix the back plate securely into position. 4. Secure the outside grille onto the back plate with the screws provided, making sure that the louvers are directed downwards. 5. Fig. 1B - By pushing the clip using a small screwdriver pull the front cover (1) away from the fan body (2). 6. The fan body (2) is secured to the base frame (4) by 4 screws. Take out each screw from the four corners (6) to dismantle and release the base frame. 7. Screw the base frame (4) to the wall using appropriate fixtures ensuring that the opening for the spigot lines up correctly with the hole made when the fan body is re-attached. 8. Take out the screw that secures the terminal block flap (5) to the fan body (2). 9. Feed the cable through the hole in the terminal block (Fig. 3). 10. Reassemble the fan body (2) to the base frame (4) and secure with 4 screws 11. Follow instructions for Electrical Connections and Wiring in B. 12. Close the terminal block flap and secure with the screw. 13. By pressing the upper and lower clips, fit the front cover back onto the fan body. 14. Switch the mains power supply on and check that the fan is working correctly

8 B. EECTRICA COECTIOS AD WIRIG IMPORTAT: ESURE THAT THE MAIS SUPPY IS SWITCHED OFF BEFORE MAKIG EECTRICA COECTIOS. KUDOS Range fans are class II (double insulation) and do not require earth connection. KUDOS S Standard version with two-speed motor, which can be voltage regulated. Proceed according to one of the following diagrams: Speed selection: Connect ive to B for trickle speed or A for boost (Fig. 3). Fig. 5A. Single-speed operation with the fan operating with independent switch. Speed is selected from either trickle or boost at installation. Please ensure that Building Regulation requirements are met when selecting the speed. Speed selection: Connect ive to B for trickle speed or A for boost (Fig. 3). Fig. 5B. Single speed operation with the fan operating through a light switch. Fig. 6A. 2-speed operation with a switch Fig. 6B. Fan operating with an REB variable speed controller KUDOS T Models with adjustable timer. The timer enables the fan to operate for the time set after the switch has been turned off (Fig. 7A). In timer mode the KUDOS fans operate at slow speed. IMPORTAT: The fan is timed to start up 50 seconds after being switched on, which means that for the first 50 seconds it does not operate. Fig. 7B. Timer based operation with the fan operating through a light switch. To set the timer function (Fig. 9A), turn the potentiometer T min situated beside the connections cover clockwise(5). The fan can be set to four timer options: 1) Auto - If the fan is used for less than 50 seconds, the timer will not come into operation. - If the fan is used for more than 50 seconds the timer is controlled automatically and operates proportionately to the time of use (time of use / x 2 with a maximum of 30 mins). 2) Position 2: Timer set to 2 minutes 3) Position 15: Timer set to 15 minutes 4) Position 30: Timer set to 30 minutes

9 KUDOS HT Models incorporating an adjustable humidity sensor that can be set between 60 and 90% relative humidity with a timer that can be adjusted between 1 and 30 minutes. In timer mode the KUDOS operates at slow speed. IMPORTAT: The humidity sensor on the KUDOS fans are factory set to 60%. To modify the factory settings, the potentiometers are situated beside the connection cover (Fig. 9B). These are fragile and must be handled with care. To increase the humidity percentage setting, turn the %Hr potentiometer clockwise (this will decrease the sensitivity). You should not attempt to adjust the settings when the fan is in timer mode. Wait until the set time has elapsed before adjusting the settings. Operation 1) Automatic working mode (Fig. 8A). The fan switches on automatically at high sped when the humidity level is above the selected value. It stops when the humidity level drops below this value and when the time set by the timer has elapsed. When the fan operates at slow speed in timer mode. 2) Automatic operation working in conjunction with a light switch (Fig. 8B). The fan will operate even if the humidity level is below the set value. When the light switch is turned off, the fan will continue to operate at slow speed for the length of time set by the timer. ATTETIO: When the relative humidity is above the set value automatic operation prevails over manual operation the fan cannot be turned off by the switch. CEAIG AD MAITEACE IMPORTAT: DISCOECT FROM THE MAIS SUPPY BEFORE CARRYIG OUT CEAIG OR MAITEACE To ensure optimum performance from your extract fan, it should be inspected and cleaned regularly to remove the build up of dust and dirt. To do so, wipe the inlets and front grille with a damp cloth. Remove the front section and hand wash in warm soapy water. Ensure that the front cover is completely dry before reassembling. AFTER SAES SERVICE We recommend you do not dismantle or remove any other parts than those mentioned, as any tampering would automatically cancel the guarantee. If you detect any fault, contact EnviroVent on Thank you for choosing EnviroVent - the fastest growing ventilation company in the UK. And remember, if you have any problems please call our dedicated Technical Team on the Hotline

10 GUARATEE The KUDOS range products are covered by a two years guarantee, subject to the specified maintenance stated within this booklet. In the event of any failure of the fan within two years of supply- excluding only wilful or careless damage we will exchange the fan free of charge. EnviroVent td Envirovent House Hornbeam Business Park Harrogate HG2 8PA ame and address of purchaser.... Model... Date of purchase... Dealer stamp

11

12 EnviroVent td EnviroVent House Hornbeam Business Park Harrogate Hg2 8PA Ref

CLASSIC-100. Instruction leaflet. Instruction leaflet

CLASSIC-100. Instruction leaflet. Instruction leaflet CASSIC-100 Instruction leaflet Instruction leaflet CASSIC-100 AXIA EXTRACTOR FAS Suitable for bathroom applications Thank you for placing your confidence in EnviroVent by buying this product. It has been

More information

Lo-Carbon Quadra SELV

Lo-Carbon Quadra SELV Lo-Carbon Quadra SELV Installation and Wiring Instructions Stock Ref. N Quadra SVTP 442865 Quadra SVHTP 442866 Quadra SVTM 442867 Safety Extra Low Voltage IPX7 PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH

More information

ECo 2 Wall INSTALLATION GUIDE FOR ENGINEER / INSTALLER

ECo 2 Wall INSTALLATION GUIDE FOR ENGINEER / INSTALLER ECo 2 INSTALLATION GUIDE FOR ENGINEER / INSTALLER Safety IMPORTANT Be sure to have read and understood these instructions before beginning the installation process. PRE-INSTALLATION CHECK LIST The ECO

More information

VA100 SELV 12 RANGE. Installation and Wiring Instructions IPX7

VA100 SELV 12 RANGE. Installation and Wiring Instructions IPX7 VA100 SEV 12 RAGE Installation and Wiring Instructions Stock Ref. VA100SV12 VA100SVX12 VA100SVXT12 VA100SVH12 VA100SVXH12 VA100SVXHT12 25 81 10D 25 83 10D 25 84 10D 25 81 12E 25 83 12E 25 85 12B FA UITS

More information

MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER

MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER Safety IMPORTANT Be sure to have read and understood these instructions before beginning the installation process. PRE-INSTALLATION CHECK LIST Make

More information

01 Safety. IMPORTANT Be sure to have read and understood these instructions before beginning the installation process.

01 Safety. IMPORTANT Be sure to have read and understood these instructions before beginning the installation process. 01 Safety IMPORTANT Be sure to have read and understood these instructions before beginning the installation process. This fan can be wall, ceiling, inline or window mounted You must ensure that any emissions

More information

Lo-Carbon Quadra Centrifugal Fan

Lo-Carbon Quadra Centrifugal Fan Lo-Carbon Quadra Centrifugal Fan Installation and Wiring Instructions Stock Ref. N Quadra TP Quadra TM Quadra HTP 439251A 439253A 439181A 220-240V~50Hz IPX4 PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH

More information

Wiring the fan correctly...

Wiring the fan correctly... You are about to install a product that is designed to outlast the life-cycle of the building. Once installed the unit will operate continuously for 7 years and beyond without a major service. Please therefore

More information

Thank you for choosing EnviroVent

Thank you for choosing EnviroVent Contents 01 Introduction 2 02 Technical Specification 3-4 03 Wiring Diagrams 5-6 04 Safety 7-8 05 Controls 8 06 Box Contents 9 07 Tools Checklist 10 08 Installation Steps 11 09 Installation 12-22 10 RF

More information

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. Centra o-carbon COTIUOUS EXTRACT FA Installation and Wiring Instructions Stock Ref. 44 29 54 Timer (T) 44 29 55 Humidistat-Timer (HT) 44 30 45 Humidistat-Timer- Pullcord. (HTP) 220-240V~50Hz PEASE READ

More information

HOTLINE:

HOTLINE: You are about to install a product that is designed to outlast the life-cycle of the building. Once installed the unit will operate continuously for 5 years and beyond without a major service. Please therefore

More information

Centrif Duo & Centrif Duo Plus

Centrif Duo & Centrif Duo Plus Centrif Duo & Centrif Duo Plus Installation and Wiring Instructions Stock Ref. N Centrif Duo P 25 61 20D Centrif Duo T 25 62 20D Centrif Duo DP 25 63 20D Centrif Duo HTP 25 64 20D Centrif Duo Centrif Duo

More information

Wiring the fan correctly...

Wiring the fan correctly... You are about to install a product that is designed to outlast the life-cycle of the building. Once installed the unit will operate continuously for 7 years and beyond without a major service. Please therefore

More information

November This product has been reconfigured Please read these instructions

November This product has been reconfigured Please read these instructions November 2013 This product has been reconfigured Please read these instructions Contents Page 01 Introduction 2 02 Box Contents 3-4 03 Tools Checklist 5 03A Pre-Installation Checklist 6 04 Controls 6 05

More information

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit DC Heat Recovery Unit MVHR Wholehouse heat recovery unit Stock Ref. N DC Heat Recovery Unit MVHR 443423 Installation, Maintenance & Users Instructions PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

More information

Thank you for choosing EnviroVent

Thank you for choosing EnviroVent 01 Introduction Thank you for choosing EnviroVent The fastest growing ventilation company in the UK You are about to install a product that is designed to outlast the life-cycle of the building. Once installed

More information

HOTLINE:

HOTLINE: You are about to install a product that is designed to outlast the life-cycle of the building. Once installed the unit will operate continuously for 5 years and beyond without a major service. Please therefore

More information

Thank you for choosing EnviroVent

Thank you for choosing EnviroVent 01 Introduction Thank you for choosing EnviroVent The fastest growing ventilation company in the UK You are about to install a product that is designed to outlast the life-cycle of the building. Once installed

More information

230V & SELV INSTALLATION GUIDE FOR ENGINEER / INSTALLER IPX4 IPX5

230V & SELV INSTALLATION GUIDE FOR ENGINEER / INSTALLER IPX4 IPX5 230V & SELV INSTALLATION GUIDE FOR ENGINEER / INSTALLER IPX4 IPX5 Safety IMPORTANT Be sure to have read and understood these instructions before beginning the installation process. This fan can be wall,

More information

Lo-Carbon SOLO Plus SELV Centrifugal Bathroom/Toilet Fan

Lo-Carbon SOLO Plus SELV Centrifugal Bathroom/Toilet Fan Lo-Carbon SOLO Plus SELV Centrifugal Bathroom/Toilet Fan Installation and Wiring Instructions Stock Ref. N 427485B (P) 427486B (T) 427487B (HT) 427488B (TM) FAN UNITS 12V DC SELV (CLASS III) CONTROLLERS

More information

Lo-Carbon SELV Tempra

Lo-Carbon SELV Tempra Lo-Carbon SELV Tempra THROUGH THE WALL HEAT RECOVERY FAN Installation and Wiring Instructions DRAFT Stock Ref. N 444368 Pullcord. (SVP) 444369 Timer. (SVT) 444370 Humidistat -Timer Pullcord. (SVHTP) 220-240V~50Hz

More information

Lo-Carbon Quadra Centrifugal Fan

Lo-Carbon Quadra Centrifugal Fan Lo-Carbon Quadra Centrifugal Fan Installation and Wiring Instructions Stock Ref. N Quadra TP Quadra TM Quadra HTP 439251A 439253A 439181A 220-240V~50Hz IPX4 PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH

More information

Internal/External Wall/Window Fan Range GX6. Installation and maintenance instructions Retain for future use

Internal/External Wall/Window Fan Range GX6. Installation and maintenance instructions Retain for future use Internal/External Wall/Window Fan Range GX6 Installation and maintenance instructions Retain for future use A GLASS WINDOW B C D ( 6 see F ) 13 E1 E2 E3 G1 G2 G3 G4 H I GB Xpelair GX6, GXC6, GXC6T, GX6HT

More information

energisava 200 CEILING MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER

energisava 200 CEILING MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER energisava 200 CEILING MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER Safety Be sure to have read and understood these instructions before beginning the installation process. PRE-INSTALLATION

More information

WHHR Midi & Midi Lite

WHHR Midi & Midi Lite WHHR Midi & Midi Lite Residential Whole House Heat Recovery Units with Low Energy EC Motors Optional - Integral LCD Installation, Operating and Maintenance Instructions Image of model with LCD screen Page

More information

Fig.2. Fig.3. Fig.4 L N L N

Fig.2. Fig.3. Fig.4 L N L N SIET-200 Instrucciones de montaje Instruction leaflet otice de montage Montageanweisungen Montage-en gebruiksaanwijzing Instrucções para a montagem Istruzioni per l'installazione Användar instruktion Brugervejledning

More information

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. Silhouette Installation and Wiring Instructions Stock Ref. N 45 40 55B (100B) 44 51 61 (125B) 45 40 59B (150X) 45 40 56B (100T) 44 51 62 (125T) 45 40 60B (150XT) 45 40 57B (100HT) 44 51 63 (125HT) 45 40

More information

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Installation and Maintenance Instructions Retain for future reference 3. To remove the impeller, unscrew the central screw with a 7mm nut runner

More information

Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System Installation Instructions

Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System Installation Instructions Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System Installation Instructions Commissioning Data: To be completed by the Commissioning Engineer. Refer to User/Homeowner Guide

More information

Fig.2. Fig.3. Fig.4 L N L N

Fig.2. Fig.3. Fig.4 L N L N SIET-300 Instrucciones de montaje Instruction leaflet otice de montage Montageanweisungen Montage-en gebruiksaanwijzing Instrucções para a montagem Istruzioni per l'installazione Användar instruktion Brugervejledning

More information

energisava 200 WALL & FLOOR MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER

energisava 200 WALL & FLOOR MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER energisava 200 WALL & FLOOR MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER Safety Be sure to have read and understood these instructions before beginning the installation process. PRE-INSTALLATION

More information

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. Silhouette Lo-Carbon RANGE 100/150mm AXIAL EXTRACT FAN Installation and Wiring Instructions Stock Ref. N 44 16 24-100B 44 16 25-100T 44 16 26-100HT 44 16 28-150B 44 16 29-150T 44 16 30-150HT 220-240V~50Hz

More information

Installation and Maintenance

Installation and Maintenance 1.0 Introduction MRXBOX-ECO2 (Standard Unit) MRXBOX-ECO2-OH (Opposite hand Unit) MRXBOXAB-ECO2 (Standard Unit) MRXBOXAB-ECO2-OH (Opposite hand Unit) Mechanical Ventilation Units with Heat Recovery for

More information

Fig.2. Fig.3. Fig.4 L N L N

Fig.2. Fig.3. Fig.4 L N L N SIET-100 Instrucciones de montaje Instruction leaflet otice de montage Montageanweisungen Montage-en gebruiksaanwijzing Instrucções para a montagem Istruzioni per l'installazione Användar instruktion Brugervejledning

More information

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS. Eclipse Installation and Wiring Instructions Models Eclipse 100X Eclipse 100XP Eclipse 100XT Eclipse 150X Eclipse 150XP Ref No. 42 73 10A 42 72 81A 42 72 82A 42 72 83A 42 73 13A 220-240V~50Hz PLEASE READ

More information

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Intake air from outside

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Intake air from outside MRXOX95-WH1 Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance The EMC Directive 2004/108/EC The ow Voltage Directive 2006/95/EC 1.0 Introduction The unit must

More information

VA 150 A, VA 150 P WINDOW EXTRACT FAN. Installation and Wiring Instructions V/1/50Hz

VA 150 A, VA 150 P WINDOW EXTRACT FAN. Installation and Wiring Instructions V/1/50Hz VA 150 A, VA 150 P WINDOW EXTRACT FAN Installation and Wiring Instructions VA150 P STOCK Ref: 152110B VA150 A STOCK Ref: 153110B 220-240V/1/50Hz READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS PLEASE

More information

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref.

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref. Lo-Carbon MULTIVENT MVDC-MS & VENTILATION SYSTEMS Installation and Wiring Instructions Stock Ref. N MVDC-MS 76A 98 0-0V~50Hz PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH THE ILLUSTRATIONS. PLEASE SAVE

More information

Watch the heatsava video

Watch the heatsava video 01 heatsava Benefits 02 What is the heatsava? 03 How does the heatsava work? Watch the heatsava video 04 Exploded view 05 Controls 06 Cleaning 07 Servicing 08 Guarantee Scan the QR code to watch the video

More information

ELIX 1003 IPX4. Energy Efficient Centrifugal Fan with EC Motor Installation and Operating Instructions

ELIX 1003 IPX4. Energy Efficient Centrifugal Fan with EC Motor Installation and Operating Instructions ELIX 1003 Energy Efficient Centrifugal Fan with EC Motor Installation and Operating Instructions 3 speed continuous running SAP Appendix Q Eligible 3 models: - standard - timer - humidity control for all

More information

Installation and Maintenance

Installation and Maintenance MRXBOXAB-ECO4 (Standard Unit) MRXBOXAB-ECO4-OH (Opposite hand Unit) Mechanical Ventilation Units with Heat Recovery and Heat Exchanger Bypass for Wall Mounting Installation and Maintenance The EMC Directive

More information

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans Installation and Maintenance IPX4* The EMC Directive 2014/30/EU The Low Voltage Directive 2014/35/EU 1.0 SAFETY INFORMATION

More information

isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans

isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans Installation and Maintenance IPX4* The EMC Directive 2014/30/EU The Low Voltage Directive 2014/35/EU 1.0 SAFETY INFORMATI The installation

More information

T-SERIES. Wall & Panel Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

T-SERIES. Wall & Panel Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz T-SERIES Wall & Panel Models Installation, Set-up and Operating Instructions Stock Ref. Nos. WIRED 456166A (9" WL) 456167A (9" PL) 456174A (12" WL) 456175A (12" PL) WIRELESS 456170A (9" WL) 456171A (9"

More information

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2 INTEGRA PLUS Installation and Wiring Instructions Stock Ref. N INTEGRA PLUS 437666 230V~ 50Hz ABC PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS. IPX2 VENT-AXIA

More information

IF IN DOUBT, INSTALLATION SHOULD BE MADE BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH CURRENT WIRING REGULATIONS.

IF IN DOUBT, INSTALLATION SHOULD BE MADE BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH CURRENT WIRING REGULATIONS. INSTALLATION/OPERATING INSTRUCTIONS FOR C100 & C100T Thank you for purchasing a quality Extractor fan from Greenbrook. Please read these instructions fully prior to initial use. Every effort has been made

More information

MRXBOX95-WALL. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Extract air.

MRXBOX95-WALL. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Extract air. MRXBOX95-WA Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance The EMC Directive 2004/108/EC The ow Voltage Directive 2006/95/EC 1.0 Introduction Figure 2. Fixing

More information

T-SERIES. Window & Roof Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

T-SERIES. Window & Roof Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz T-SERIES Window & Roof Models Installation, Set-up and Operating Instructions Stock Ref. Nos. WIRED 456165A (9" WW) 456168A (9" RF) 456173A (12" WW) 456176A (12" RF) WIRELESS 456169A (9" WW) 456172A (9"

More information

GUH90 90 cm Canopy Hood

GUH90 90 cm Canopy Hood User Manual for your GUH90 90 cm Canopy Hood NOTE: This User Instruction Manual contains important information, including safety & installation points, which will enable you to get the most out of your

More information

Xpelair Simply Silent TM DX100 Fan

Xpelair Simply Silent TM DX100 Fan Xpelair Simply Silent TM DX100 Fan Installation and Maintenance Instructions DX100R (93005AW) / DX100S (93025AW) DX100TR (93006AW) / DX100TS (93026AW) DX100PR (93007AW) / DX100PS (93027AW) DX100HTR (93008AW)

More information

Xpelair Simply Silent TM Contour Fan

Xpelair Simply Silent TM Contour Fan Xpelair Simply Silent TM Contour Fan Installation and Maintenance Instructions C4S (92960AW) / C4R (92961AW) C4TS (92962AW) / C4TR (92963AW) C4PS (92964AW) / C4PR (92965AW) C4HTS (92966AW) / C4HTR (92967AW)

More information

ELEGANCE IPX4 IPX7. Low Carbon Fan with EC Motor Installation and Operating Instructions. 6 models:

ELEGANCE IPX4 IPX7. Low Carbon Fan with EC Motor Installation and Operating Instructions. 6 models: ELEGANCE Low Carbon Fan with EC Motor Installation and Operating Instructions 6 models: - SAP Appendix Q Eligible 3 speed continuous running - timer - humidity control - SELV - low voltage for all domestic

More information

Silhouette Installation and Wiring Instructions

Silhouette Installation and Wiring Instructions Silhouette Installation and Wiring Instructions Stock Ref. N 45 40 55B (100B) 44 51 61 (125B) 45 40 59B (150X) 45 40 56B (100T) 44 51 62 (125T) 45 40 60B (150XT) 45 40 57B (100HT) 44 51 63 (125HT) 45 40

More information

230V/24V DC SELV Surface and Semi-Recessed Mounted Domestic Fans INSTALLATION AND MAINTENANCE. n Wall mounting kit

230V/24V DC SELV Surface and Semi-Recessed Mounted Domestic Fans INSTALLATION AND MAINTENANCE. n Wall mounting kit CYFA-C EXTRACT FAS 230V/24V DC SEV Surface and Semi-Recessed Mounted Domestic Fans ISTAATIO AD MAITEACE The EMC Directive 2014/30/EU The ow Voltage directive 2014/35/EU * IPX4 SECTIO 1.0 ITRODUCTIO CYFA-C

More information

MEV-DC. Continuous Mechanical Extract Ventilation Units Installation and Maintenance. Figure 3. Fixing screw hole.

MEV-DC. Continuous Mechanical Extract Ventilation Units Installation and Maintenance. Figure 3. Fixing screw hole. MEV-DC Continuous Mechanical Extract Ventilation s Installation and Maintenance The EMC Directive 2014/30/EU The ow Voltage directive 2014/35/EU 1.0 Introduction uaire's MEV-DC units are designed to provide

More information

GUH52SD 52 cm GUH75 75 cm Canopy Hood

GUH52SD 52 cm GUH75 75 cm Canopy Hood User Manual for your GUH52SD 52 cm GUH75 75 cm Canopy Hood NOTE: This User Instruction Manual contains important information, including safety & installation points, which will enable you to get the most

More information

dmev Unit Quietest dmev available. Discreet, tasteful styling. Single fan for use in all applications.

dmev Unit Quietest dmev available. Discreet, tasteful styling. Single fan for use in all applications. Centra dmev Unit 62kg* carbon 80% energy E S P l i g i b l e Q P P E N D I X Part F compliant, System 3 IPX4 rated Continuous mechanical extract. Constant volume option. SP ppendix Q eligible - Low SFP

More information

Xpelair Simply Silent DX100

Xpelair Simply Silent DX100 Xpelair Simply Silent DX100 English Nederlands Installation n and Maintenance Instructions Installa en Onderho ru DX100R (93005AW) DX100S (93025AW) DX100TR (93006AW) DX100TS (93026AW) DX100HPTR (93009AW)

More information

Xpelair Simply Silent DX150

Xpelair Simply Silent DX150 English Xpelair Simply Silent DX150 Installation and Maintenance Instructions DX150S (93070AW) DX150R (93071AW) DX150TS (93072AW) DX150TR (93073AW) DX150PS (93074AW) DX150PR (93075AW) DX150HTS (93076AW)

More information

Purge Ventilation Unit. Product Manual. ventilation systems TP625

Purge Ventilation Unit. Product Manual. ventilation systems TP625 EN Purge Ventilation Unit TP625 Product Manual ventilation systems Warnings, Safety Information and Guidance Important Information Important: read these instructions fully before the installation of this

More information

Simply Silent Contour 4 (100mm) Axial Extraction Fan

Simply Silent Contour 4 (100mm) Axial Extraction Fan Simply Silent Contour 4 (100mm) Axial Extraction Fan Suitable for bathrooms, toilets, shower and utility rooms Controls humidity, odours and mould growth Sleek low-profile design, wall or ceiling mounting

More information

FLAT2000L/R. Low Energy Positive Input Ventilation Unit. Installation and Maintenance. Alternative inlet position. 2.1 Spigot Inserts.

FLAT2000L/R. Low Energy Positive Input Ventilation Unit. Installation and Maintenance. Alternative inlet position. 2.1 Spigot Inserts. FAT2000/R ow Energy Positive Input Ventilation Unit Installation and Maintenance The EMC Directive 204/0/EU The ow Voltage Directive 204/5/EU.0 ITRODUCTIO The uaire Drimaster/Flatmaster range has been

More information

PIV & MIV Loft Mounted Unit INSTALLATION GUIDE FOR ENGINEER / INSTALLER

PIV & MIV Loft Mounted Unit INSTALLATION GUIDE FOR ENGINEER / INSTALLER PIV & MIV Loft Mounted Unit INSTALLATION GUIDE FOR ENGINEER / INSTALLER Made in Harrogate UK Thank you for choosing EnviroVent The fastest growing ventilation company in the UK. You are about to install

More information

Filterless Infinity Designed to Perform. Built to Last. WC, Bathroom & Kitchen

Filterless Infinity Designed to Perform. Built to Last. WC, Bathroom & Kitchen Filterless Infinity Designed to Perform. Built to Last. WC, Bathroom & Kitchen EnviroVent has been continually refining Filterless extract technology since it invented it 10 years ago, which has reduced

More information

Integra. Integra Plus EC MVHR. Installation & Commissioning. Stock Ref. N EC Integra Plus EC PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT.

Integra. Integra Plus EC MVHR. Installation & Commissioning. Stock Ref. N EC Integra Plus EC PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT. Integra Integra Plus EC MVHR Installation & Commissioning Stock Ref. N 437666EC Integra Plus EC PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT. Copyright 2009 Vent-Axia Limited. All rights reserved.

More information

Lo-Carbon T-series Window & Roof Models

Lo-Carbon T-series Window & Roof Models Lo-Carbon T-series Window & Roof Models Installation & User Instructions WIRED 456165A (9 WW) 456168A (9 RF) 456173A (12 WW) 456176A (12 RF) WIRELESS 456169A (9 WW) 456172A (9 RF) 456177A (12 WW) 456180A

More information

TEMPAIR 3 IN 1 EXHAUST FAN SKU# &

TEMPAIR 3 IN 1 EXHAUST FAN SKU# & TEMPAIR 3 IN 1 EXHAUST FAN SKU# 200290 & 200291 CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION. WARRANTY - This product is covered by a 3 year warranty. The warranty is from

More information

60cm Chimney Extractor

60cm Chimney Extractor 60cm Chimney Extractor LAM2401 HJA2480 User & Installation Guide Contents Page Environmental note 3 IMPORTANT SAFETY INFORMATION 4 6 Specifications of your extractor 7 8 Dimensions 7 Specifications 7-8

More information

energisava 200 High performance in a compact unit High Efficiency Whole House Heat Recovery System

energisava 200 High performance in a compact unit High Efficiency Whole House Heat Recovery System energisava 200 High performance in a compact unit High Efficiency Whole House Heat Recovery System energisava 200 High Efficiency Whole House Heat Recovery System Joining the high efficiency energisava

More information

Installation and Maintenance

Installation and Maintenance 1.0 INTRODUCTION MRXBOXAB-ECO-LP1 (Standard Unit) MRXBOXAB-ECO-LP1-OH (Opposite Hand Unit) Mechanical Ventilation Unit with Heat Recovery for Ceiling Void Mounting Installation and Maintenance The LP1

More information

OPUSXBOX - SMALL COMMERCIAL HEAT RECOVERY SYSTEM LOW DEPTH, HEAT RECOVERY UNIT WITH MULTIPLE SPIGOTS AND ECOSMART CONTROLS.

OPUSXBOX - SMALL COMMERCIAL HEAT RECOVERY SYSTEM LOW DEPTH, HEAT RECOVERY UNIT WITH MULTIPLE SPIGOTS AND ECOSMART CONTROLS. - SMA COMMERCIA HEAT RECOVERY SYSTEM OW DEPTH, HEAT RECOVERY UIT WITH MUTIPE SPIGOTS AD ECOSMART COTROS. 34 09 085 800 AIR HADIG UITS (AHU S) TECHICA IFORMATIO BEEFITS OW DEPTH 185MM The shallowest available,

More information

100cm Chimney Hood GB IE

100cm Chimney Hood GB IE 100cm Chimney Hood GB IE [01] x 1 [02] x 2 [03] x 2 [04] x 2 [05] x 3 [06] x 1 [07] x 1 1 : 1 [09] x 8 (3.9 x 32mm) [08] x 8 [10] x 4 (4 x 12mm) 100cm Chimney Hood GB IE Cooker Hood 04 FR Hotte Aspirante

More information

Unity CV2GIP Decentralised Mechanical Extract Ventilation (dmev) Installation Instructions

Unity CV2GIP Decentralised Mechanical Extract Ventilation (dmev) Installation Instructions Unity CV2GIP Decentralised Mechanical Extract Ventilation (dmev) Installation Instructions Commissioning Data: To be completed by the Commissioning Engineer. Refer to User / Homeowner Guide also supplied.

More information

Installation and Maintenance

Installation and Maintenance MRXBOXAB-ECO4-SW (Standard Unit) MRXBOXAB-ECO4-OHSW (Opposite hand Unit) Mechanical Ventilation Units with Heat Recovery and Heat Exchanger Bypass for Wall Mounting The EMC Directive 014/30/EU The Low

More information

nergybulbs.co.uk Domestic AC Fans 230V Installation and Operating Guide Quick Order Hotline or

nergybulbs.co.uk Domestic AC Fans 230V Installation and Operating Guide Quick Order Hotline or Domestic AC Fans 230V Installation and Operating Guide 230V AC Base Models: ico15 72683501 ico15c 72591501 ico30 72591601 ico60 72591701 ico Domestic Fan 230V Installation, Maintenance and Use ico Domestic

More information

GEH9026G Cooker Hood

GEH9026G Cooker Hood User Manual for your GEH9026G Cooker Hood 90 cm Chimney Hood in Stainless Steel NOTE: This User Instruction Manual contains important information, including safety & installation points, which will enable

More information

Decentralised Mechanical Extract Ventilation 2 Speed Axial Extract Fan Installation Guide. Fig. 2 Fan components.

Decentralised Mechanical Extract Ventilation 2 Speed Axial Extract Fan Installation Guide. Fig. 2 Fan components. 1.0 Introduction The dmev 2 speed axial extract fan has been designed for continuous ventilation for kitchens or wet rooms and should be installed using 100mm dia. ducting. The unit can be installed in

More information

Introducing the RetroVent

Introducing the RetroVent Fans For Life Introducing the RetroVent Features Benefits Made in the UK Flying the flag for UK manufacturing, lower carbon footprints and total control over quality Tubular heat recovery cell Designed

More information

EKF. EC kitchen extract fan range. Installation and Wiring Instructions. Stock Ref. N EKF355E1 EKF400E1 EKF450E1 EKF450E3 EKF500E3 EKF560E3

EKF. EC kitchen extract fan range. Installation and Wiring Instructions. Stock Ref. N EKF355E1 EKF400E1 EKF450E1 EKF450E3 EKF500E3 EKF560E3 EKF EC kitchen extract fan range Installation and Wiring Instructions Stock Ref. N EKF355E1 EKF400E1 EKF450E1 EKF450E3 EKF500E3 EKF560E3 PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH THE ILLUSTRATIONS.

More information

ECO dmev Decentralised MEV

ECO dmev Decentralised MEV ECO dmev Decentralised MEV The ECO dmev has been designed and developed to offer the market a constant volume, continuously running decentralised extract fan to achieve the lowest power consumption, the

More information

Trimbox Mixed Flow Fans. Product Manual. ventilation systems TP220T TP221T TP222T TP223T

Trimbox Mixed Flow Fans. Product Manual. ventilation systems TP220T TP221T TP222T TP223T EN Trimbox Mixed Flow Fans TP220T TP221T TP222T TP223T Product Manual ventilation systems Safety Information Important Information Important: read these instructions fully before the installation of this

More information

Titon CME1 Q Plus Mechanical Extract Ventilation Unit

Titon CME1 Q Plus Mechanical Extract Ventilation Unit Titon CME1 Q Plus Mechanical Extract Ventilation Unit Product Manual ventilation systems 2 PCT Patent Application No PCT/GB2009/000114 Contents This is the Product Manual for the Titon CME1 Q Plus Introduction...................................

More information

LV100 Standard LV100PC Pull Cord LV100T Timer LV100H Humidistat LV100HP Humidistat and Pull Cord LV100PIR

LV100 Standard LV100PC Pull Cord LV100T Timer LV100H Humidistat LV100HP Humidistat and Pull Cord LV100PIR Installation and operating instructions LV100 Standard LV100PC Pull Cord LV100T Timer LV100H Humidistat LV100HP Humidistat and Pull Cord Safety extra low voltage toilet/bathroom 100mm fan range Integral

More information

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside MRXBOX95-WM1 (Standard Unit) MRXBOX95-WM1-OH (Opposite hand Unit) MRXBOX95AB-WM1 (Standard Unit) MRXBOX95AB-WM1-OH (Opposite hand Unit) Mechanical Ventilation Units with Heat Recovery for Wall Mounting

More information

9 inch and 12 inch Axial Fans Models MV230P, MV230AR and MV300AR Instructions for installation, maintenance and safe use.

9 inch and 12 inch Axial Fans Models MV230P, MV230AR and MV300AR Instructions for installation, maintenance and safe use. 9 inch and 12 inch Axial Fans Models MV230P, MV230AR and MV300AR Instructions for installation, maintenance and safe use. Contents: Section 1: Options. Page 2 Section 5: Wiring instructions Page 2 & 3

More information

HR100R. Mini Air Handling Unit - For Ducted Ventilation With Heat Recovery. Installation and Servicing Instructions

HR100R. Mini Air Handling Unit - For Ducted Ventilation With Heat Recovery. Installation and Servicing Instructions HR100R Please leave these instructions with the user Mini Air Handling Unit - For Ducted Ventilation With Heat Recovery Installation and Servicing Instructions Contents Section Page 1.0 Introduction 4

More information

HR200WK Through the wall Heat Recovery Ventilator

HR200WK Through the wall Heat Recovery Ventilator HR200WK Through the wall Heat Recovery Ventilator Installation and Maintenance Instructions Stock Ref No:- HR200WK 14120020 PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE

More information

Lucci Designer Hi Flow Exhaust Fan

Lucci Designer Hi Flow Exhaust Fan USE AND CARE INSTRUCTION INSTALLATION INSTRUCTION Lucci Designer Hi Flow Exhaust Fan SKU# 200265&200267 MXSQ8PW(200mm) SKU# 200266&200268 MXSQ10PW(250mm) Dear Customers, Thank you for selecting a LUCCI

More information

BWT6.3GL Cooker Hood 60 cm Glass chimney hood

BWT6.3GL Cooker Hood 60 cm Glass chimney hood User Manual for your BWT6.3GL Cooker Hood 60 cm Glass chimney hood NOTE: This User Instruction Manual contains important information, including safety & installation points, which will enable you to get

More information

"WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use

WHHR125DC Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use "WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor Installation, Operating and Maintenance Instructions domestic and commercial use Page 2 Contents Section Page Number Introduction 3 How

More information

fact fact fact result No quibble, 7 year warranty. No strings attached. No fans going to landfill sites Happy tenants Money saved

fact fact fact result No quibble, 7 year warranty. No strings attached. No fans going to landfill sites Happy tenants Money saved EnviroVent has been continually refining Filterless extract technology since it invented it 10 years ago, which has reduced social housing landlord s extractor fan maintenance costs by tens of millions

More information

Xpelair Simply Silent DX100B

Xpelair Simply Silent DX100B Xpelair Simply Silent DX100B Installation and Maintenance Instructions English DX100BR (92997AW) DX100BS (93017AW) DX100BTR (92998AW) DX100BTS (93018AW) DX100BHTR (92999AW) DX100BHTS (93019AW) DX100BHPTR

More information

Installation and Maintenance Instructions for the Installer. Please refer to the User Manual for instructions on how to operate the system

Installation and Maintenance Instructions for the Installer. Please refer to the User Manual for instructions on how to operate the system Heat Recovery Ventilation Applicable to aircycle 1.1/1.2 (Ws - For Wall Mounting with In-built Control & Summer Bypass) Installation and Maintenance Instructions for the Installer. Please refer to the

More information

60cm Integrated Turbo Extractor

60cm Integrated Turbo Extractor 60cm Integrated Turbo Extractor LAM2201 User & Installation Guide Dear Customer, Congratulations on your choice of domestic appliance which has been designed to give you excellent service. The user manual

More information

irconcentre.co.uk airooncentre.co.uk

irconcentre.co.uk airooncentre.co.uk Installation and maintenance instructions DX100 Standard DX100PC Pull Cord DX100T Timer DX100H Humidistat DX100HP Humidistat and Pull Cord DX100PIR Integral Body Movement Sensor DX100VTD Delay Timer Toilet/Bathroom

More information

Installation and Maintenance

Installation and Maintenance 1.0 INTRODUCTION MRXBOXAB-ECO-LP1SW (Standard Unit) MRXBOXAB-ECO-LP1-OHSW (Opposite Hand Unit) Mechanical Ventilation Unit with Heat Recovery for Ceiling Void Mounting Installation and Maintenance The

More information

SLIMAIRE 230V & 12V SINGLE SPEED FANS

SLIMAIRE 230V & 12V SINGLE SPEED FANS SIMAIRE SIGE SPEED TECHIC A IFORMATIO SIMAIRE & 12V SIGE SPEED FAS EXCEPTIOAY QUIET, HIGH PERFORMACE EXTRACT FAS FOR WA AD CEIIG APPICATIOS. 118 029 2085 8200 SIMAIRE SIGE SPEED TECHIC A IFORMATIO BEEFITS

More information

BT16.4SS-HK BT19.4SS-HK Cooker Hood

BT16.4SS-HK BT19.4SS-HK Cooker Hood BT16.4SS-HK BT19.4SS-HK Cooker Hood User Manual for your Baumatic User Manual for your Baumatic BT16.4SS-HK 60 cm Chimney Hood BT19.4SS-HK 90 cm Chimney Hood NOTE: This User Instruction Manual contains

More information

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. VA100 Lo-Carbon RANGE 100mm AXIAL EXTRACT FAN Installation and Wiring Instructions Stock Ref. N 44 31 59 - LP 44 31 60 - XP 44 31 61 - LT 44 31 62 - XT 44 31 63 - LHTP 44 31 64 - XHTP 220-240V~50Hz PLEASE

More information

Models: RP-10, RP-15, RP-20. User Manual

Models: RP-10, RP-15, RP-20. User Manual Models: RP-10, RP-15, RP-20 User Manual Contents Thank you for purchasing the Ducasa Sunburst Radiant Panel Heater. Index Safety Precautions & Important Safeguards:... 3 Specifications:... 5 Features...

More information