CITY MULTI VRF System Pipe Accessories
|
|
- Aubrey Conley
- 5 years ago
- Views:
Transcription
1 ITY MULTI VRF System Pipe ccessories Job Name: System Reference: ate: PIPE ESSORIES Model Number ompatible Model apacity (tu/h) ranches Twinning Kits MY-Q100K R2-Series Water Source - - MY-R100K2 R2-Series ir Source - - MY-R100XLK R2-Series ir Source - - MY-ER100K R2-Series ir Source - - MY-ER200K R2-Series ir Source - - MY-Y100K3 Y-Series ir Source - - MY-Y200K2 Y-Series ir Source - - MY-Y300K2 Y-Series ir Source - - Joint Kits MY-Y102SS-G2 R2/Y-Series ir Source 72,000 - MY-Y102LS-G2 R2/Y-Series ir Source 73, ,000 - MY-Y202S-G2 R2/Y-Series ir Source 145, ,000 - MY-Y302S-G2 R2/Y-Series ir Source 235,000 - MY-Y-G-E S-Series ir Source - - Header Kits MY-Y104-G Y-Series ir Source 4-ranch 72,000 4 MY-Y108-G Y-Series ir Source 8-ranch 144,000 8 MY-Y1010-G Y-Series ir Source 10-ranch 234, MY-Y64-G-E S-Series ir Source 4-ranch - 4 MY-Y68-G-E S-Series ir Source 8-ranch - 8 Joint dapter Kit MY-R160-J See ompatibility hart below - - MY-R160-J1 See ompatibility hart below - -
2 JOINT PTER KIT OMPTIILITY HRT Model Number JOINT PTER KIT OMPTIILITY HRT ompatible Model Quantity Required MY-R160-J ontroller - MY-R160-J1 ontroller - MY-R160-J PEFY-P72NMHSU-E 1 MY-R160-J1 PEFY-P72NMHSU-E 1 MY-R160-J PEFY-P96NMHSU-E 1 MY-R160-J1 PEFY-P96NMHSU-E 1 MY-R160-J PEFY-F1200FM 2 MY-R160-J1 PEFY-F1200FM 2 MY-R160-J PEFY-F1200FMR 3 MY-R160-J1 PEFY-F1200FMR 3
3 TWINNING KIT OMPTIILITY HRT R2-SERIES WTER SOURE & IR SOURE Item escription MY-Q100K MY-R100K2 MY-R100XLK MY-ER100K MY-ER200K Water Source H-Generation PQRY-P144(T/Y)SHMU- X PQRY-P168(T/Y)SHMU- X PQRY-P192(T/Y)SHMU- X PQRY-P216(T/Y)SHMU- X PQRY-P240(T/Y)SHMU- X ir Source J-Generation PURY-P168(T/Y)SJMU- - X PURY-P192(T/Y)SJMU- - X PURY-P216(T/Y)SJMU- - - X - - PURY-P240(T/Y)SJMU- - - X - - PURY-P264(T/Y)SJMU- - - X - - PURY-P288(T/Y)SJMU- - - X - - ir Source K-Generation - Models PURY-(HP/P)144(T/Y)SKMU- - X PURY-P168(T/Y)SKMU- - X PURY-(HP/P)192(T/Y)SKMU- - X PURY-P216(T/Y)SKMU- - - X - - PURY-P240(T/Y)SKMU- - - X - - PURY-P264(T/Y)SKMU- - - X - - PURY-P288(T/Y)SKMU- - - X - - ir Source K-Generation -U Models PURY-P144(T/Y)SKMU-U - X PURY-P168(T/Y)SKMU-U - X PURY-P192(T/Y)SKMU-U - X PURY-P216(T/Y)SKMU-U - - X - - PURY-P240(T/Y)SKMU-U - - X - - PURY-P264(T/Y)SKMU-U - - X - - PURY-P288(T/Y)SKMU-U - - X - - ir Source L-Generation - Models PURY-P144(T/Y)SLMU X - PURY-P168(T/Y)SLMU X PURY-P216(T/Y)SLMU X PURY-P240(T/Y)SLMU X PURY-P264(T/Y)SLMU X PURY-P288(T/Y)SLMU X PURY-P312(T/Y)SLMU X PURY-P336(T/Y)SLMU X
4 TWINNING KIT OMPTIILITY HRT, contd. Y-SERIES WTER SOURE & IR SOURE Model Number MY-Y100K3 MY-Y200K2 MY-Y300K2 Water Source H-Generation PQHY-P144(T/Y)SHMU- X - - PQHY-P168(T/Y)SHMU- X - - PQHY-P192(T/Y)SHMU- X - - PQHY-P216(T/Y)SHMU- X - - PQHY-P240(T/Y)SHMU- X - - PQHY-P264(T/Y)SHMU- - - X PQHY-P288(T/Y)SHMU- - - X PQHY-P312(T/Y)SHMU- - - X PQHY-P336(T/Y)SHMU- - - X PQHY-P360(T/Y)SHMU- - - X ir Source J-Generation PUHY-(HP/P)144(T/Y)SJMU- X - - PUHY-P168(T/Y)SJMU- X - - PUHY-(HP/P)192(T/Y)SJMU- X - - PUHY-P216(T/Y)SJMU- X - - PUHY-P240(T/Y)SJMU- X - - PUHY-P264(T/Y)SJMU- - X - PUHY-P288(T/Y)SJMU- - X - PUHY-P312(T/Y)SJMU- - - X PUHY-P336(T/Y)SJMU- - - X PUHY-P360(T/Y)SJMU- - - X ir Source K-Generation - Models PUHY-P144YSKMU- X - - PUHY-P168(T/Y)SKMU- X - - PUHY-P192(T/Y)SKMU- X - - PUHY-P216(T/Y)SKMU- X - - PUHY-P240(T/Y)SKMU- X - - PUHY-P264(T/Y)SKMU- - - X PUHY-P288(T/Y)SKMU- - - X PUHY-P312(T/Y)SKMU- - - X PUHY-P336(T/Y)SKMU- - - X PUHY-P360(T/Y)SKMU- - - X ir Source K-Generation -U Models PUHY-P144YSKMU-U X - - PUHY-P168(T/Y)SKMU-U X - - PUHY-P192(T/Y)SKMU-U X - - PUHY-P216(T/Y)SKMU-U X - - PUHY-P240(T/Y)SKMU-U X - - PUHY-P264(T/Y)SKMU-U - - X PUHY-P288(T/Y)SKMU-U - - X PUHY-P312(T/Y)SKMU-U - - X PUHY-P336(T/Y)SKMU-U - - X PUHY-P360(T/Y)SKMU-U - - X
5 TWINNING KIT OMPTIILITY HRT, contd. Y-SERIES WTER SOURE & IR SOURE Model Number MY-Y100K3 MY-Y200K2 MY-Y300K2 ir Source L-Generation - Models PUHY-P144(T/Y)SLMU- X - - PUHY-P168(T/Y)SLMU- X - - PUHY-P192(T/Y)SLMU- X - - PUHY-P216(T/Y)SLMU- X - - PUHY-P240(T/Y)SLMU- X - - PUHY-P264(T/Y)SLMU- - - X PUHY-P288(T/Y)SLMU- - - X PUHY-P312(T/Y)SLMU- - - X PUHY-P336(T/Y)SLMU- - - X PUHY-P360(T/Y)SLMU- - - X
6 TWINNING KITS - IMENSIONS MY-Q100K Low-pressure pipe twinning kit <Elbow pipe(ccessory)> unit: mm <Pipe for routing through the front (ccessory)> High-pressure twinning pipe <eformed pipe(ccessory)> <Pipe for routing through the front (ccessory)> MY-R100K2 Low-pressure pipe twinning kit 1 <Elbow pipe(ccessory)> 1-5/32" 1-5/32" 1-31/32" unit: inch 1 1-3/32 5-1/4 17-1/32 4-5/32 1-5/ /32 1-1/4 7/8 21/ /16 1-7/ /32" 1-7/16 7/8" 7/8" <Low-pressure pipe twinning kit(ccessory)> /8 <eformed pipe(ccessory)> 7/8" 3/4 2-15/32" High-pressure twinning pipe 7/8" 1-13/32 <Pipe for routing through the bottom (ccessory)> 1" <Pipe for routing through the front (ccessory)> 1" 2-5/16" 21/32" 8-7/ /32" 7-17/32" <eformed pipe(ccessory)> 3/4 5/8 2-15/32" (3Pcs.) Ref: MY_R100VK_EX_EU_SI
7 MY-R100XLK Low-pressure pipe twinning kit O 1-1/4 TWINNING KITS - IMENSIONS, contd. unit : inch 6-15/ /32 1-9/32 I 1-5/32 1-1/32 4-9/ / /16 5-3/8 O 1-5/32 <Elbow pipe(ccessory)> I 1-1/4 1-31/32 2-3/32 I 1-1/4 2-3/32 I 1-5/32 I 1-5/32 <eformed pipe(ccessory)> O 1-5/32 O 1-1/4 I 1-13/32 I 7/8 6-5/ /32 O 1-1/4 I 1-5/32 O 7/8 I 1-5/ / / /32 High-pressure twinning pipe I 3/4 I 1-5/ /32 <eformed pipe (ccessory)> O 3/4 I 7/8 O 7/8 I 3/4 (3Pcs.) 2-15/ /32 3-5/32 I 3/4 <Pipe for routing through the bottom (ccessory)> <Pipe for routing through the front (ccessory)> I 1 I 1 O 3/4 8-7/16 21/32 I 3/4 4-17/ /32 2-5/16
8 TWINNING KITS - IMENSIONS, contd. MY-ER100K Unit: mm () Low-pressure pipe twinning kit 7 30 (5/16) (1-3/16) 100(3-15/16) ø28.58(-1/8) 407(16-1/16) 117(4-5/8) ø28.58(-1/8) 35 (1-7/16) 146(5-3/4) ø22.2(ø7/8) 17(11/16) 50(2) 36(1-7/16) <Elbow pipe(ccessory)> 50(2) 36 (1-7/16) ø28.58(-1/8) ø28.58(-1/8) ø22.2(ø7/8) ø22.2(ø7/8) <ccessory> Fixing screw 1 1 able tie 2 Insulation cover 1 uffer 1 <eformed pipe(ccessory)> 9.05() ø22.2(ø7/8) ø22.2(ø7/8) 9.05() High-pressure twinning pipe 9.05() ø22.2(ø7/8) 80(3-3/16) 9.05() 35 (1-7/16) <eformed pipe(ccessory)> 9.05() 5.88() (3Pcs.) 5.88() 9.05() 85 (3-3/8) <Pipe for routing through the bottom (ccessory)> ø25.4() 9.05() 303(11-15/16) <Pipe for routing through the front (ccessory)> 9.05() 171(6-3/4) ø25.4() 182(7-3/16) 55 (2-3/16) Note 1:Refer to the figure below for the installation position of the twinning pipe. Twinning pipe on the high-pressure side ±15 Slope of the twinning pipe is at an angle within ±15 to the horizontal plane. 2:Pipe diameter is indicated by inside diameter. MY-ER200K Low-pressure pipe twinning kit (1) (1-7/16) 136(5-3/8) 50(2) ø28.58(-1/8) 108(4-5/16) 427(16-13/16) <Elbow pipe(ccessory)> ø28.58(-1/8) ø28.58(-1/8) (2-1/8) 53 ø31.75(-1/4) ø31.75(-1/4) ø31.75(-1/4) 32 (1-5/16) 176(6-15/16) ø28.58(-1/8) 26(1-1/16) ø34.93(-3/8) <eformed pipe(ccessory)> 9.05() ø22.2(ø7/8) ø22.2(ø7/8) 9.05() ø41.28(-5/8) 69 (2-3/4) ø31.75(-1/4) ø34.93(-3/8) <ccessory> Fixing screw 1 1 able tie 2 Insulation cover 1 ø28.58(-1/8) ø22.2(ø7/8) ø31.75(-1/4) ø28.58(-1/8) 69 (2-3/4) ø22.2(ø7/8) ø28.58(-1/8) Unit: mm () 50(2) High-pressure twinning pipe 9.05() ø28.58(-1/8) 35 (1-7/16) () (3-3/16) (6-5/16) (2-1/8) <Pipe for routing through the bottom (ccessory)> <Pipe for routing through the front (ccessory)> ø25.4() 9.05() 9.05() 303(11-15/16) <eformed pipe(ccessory)> 9.05() ø22.2(ø7/8) ø28.58(-1/8) ø22.2(ø7/8) (3Pcs.) ø22.2(ø7/8) 9.05() 9.05() 5.88() 55 (2-3/16) 100(3-15/16) ø25.4() 182(7-3/16) Note 1:Refer to the figure below for the installation position of the twinning pipe. Twinning pipe on the high-pressure side ±15 Slope of the twinning pipe is at an angle within ±15 to the horizontal plane. 2:Pipe diameter is indicated by inside diameter.
9 TWINNING KITS - IMENSIONS, contd. MY-Y100K3 For Gas pipe: For Liquid pipe: Ref.: MY_Y100VK2_EX_EU_SI Note /32" 19-29/32" (ot-dashed part) 2 7/8" istributer 1" 1" 7/8" 6-5/16" Note 2 3-9/32" 7-7/32" (ot-dashed part) 9- istributer 3-7/8" 7/8" 3/8" 1-15/16" (2 pcs.) 2-15/32" (2 pcs.) 1-15/16" 7/8" 2-15/32" (2 pcs.) I: Inner iameter O: Outer iameter MY-Y200K2 For Gas pipe: For Liquid pipe: <eformed pipe(ccessory)> O 1-1/8 I 1-3/8 Note 2 (13-5/16 ) 19-13/16 I 1-1/18 (ot-dashed part) 23-1/16 istributer O 1-1/18 O 1-1/18 I 1-1/18 6-7/16 O 3/4 I 3/4 Note 2 (3-3/8 ) 7-9/16 I 5/8 (ot-dashed part) istributer 9-5/8 O 5/8 I 5/8 O 5/8 115 O 5/8 O 1-3/8 1-15/16 (2 pcs.) 2-3/4 I 1/2 I 1-5/8 I: Inner iameter O: Outer iameter MY-Y300K2 For Gas pipe: For Liquid pipe: Ref.: MY_Y300VK2_EX_EU_SI 1-1/4" 19-15/16" (ot-dashed part) 1-3/8" 6-7/16" 7-9/16" 4-9/16" /8" 1-15/16" 3/8" 1-1-3/8" Note /8" Note /16" 22-15/16" 19-11/16" (ot-dashed part) istributer 1" 1" 6-7/16" Note 2 3-3/8" (ot-dashed part) istributer 9-11/16" 7-5/16" Note 2 (ot-dashed part) 3-3/8" istributer 9-3-7/8" 2- (3 pcs.) 1-15/16" 3/8" 1-15/16" (2 pcs.) /16" 1-3/8" 2-2- (2 pcs.) 23-1/16" istributer I: Inner iameter O: Outer iameter
10 JOINT KITS - IMENSIONS MY-Y102SS-G2 For Gas pipe: /2 For Liquid pipe: 1-1/8 1-3/16 3/4 /4 2-5/16 1-3/16 /2 1-7/16 13/16 *Pipe diameter is indicated by inside diameter. 1-1/2 MY-Y102LS-G2 For Gas pipe: /2-1/8 For Liquid pipe: 1-9/ /2 2-3/16 1-3/16 1-5/8 ø7/8 2-3/16 ø7/8 1-13/16 13/16 /2 /2 1-5/8 /4 13/16 /2 15/16 *Pipe diameter is indicated by inside diameter. 1-11/16 MY-Y202S-G2 For Gas pipe: 1-9/16 3 /2 1-1/2 1-3/16 ø7/8 2-3/16 ø7/8 2-3/16 (3 Pcs.) 2-3/16-1/8 15/16 For Liquid pipe: /2 1-15/16 1-1/8 /2 15/16 /2 15/16 /2 /4 *Pipe diameter is indicated by inside diameter. 1-11/16 1-1/8 MY-Y302S-G2 For Gas pipe: 1-13/16-1/4 3-15/16-1/4 ø7/8 1-5/8 1-11/16 /2 1-13/ /16-1/4-3/8-1/8 2-3/4 2-3/16-1/4-5/8-1/4-1/8 1-3/16 For Liquid pipe: 2-5/16 /2 1-1/8 1-1/8 /2 /4 1-1/2 1-1/8 1-3/16 *Pipe diameter is indicated by inside diameter. 1-13/16 2-3/4
11 JOINT KITS - IMENSIONS, contd. MY-Y-G 1. Specification Ref.: 7FGF Main ccessory Items Number of ports Number of branch joints Pipe material Insulation material Reducer etails 2 ports One for each liquid and gas pipe Phosphorus deoxidized copper 1220T-OL (JIS H3300) Foamed polyethylene (one for each liquid and gas pipe) 10 reducers of 7 types (Refer to the external drawing for details.) 2. External drawing For liquid pipe: 1-9/16" Inner iameter 3/8" Note) onnection only to downstream units Reducer (ccessory): For gas pipe: 3-9/32" (External view : 3-9/32"X3-3/16"X1-23/32") 1-25/32" Inner iameter 3/8" 2-15/16" 1-31/32" Inner iameter 3-3/16" 3-15/16" 5-29/32" 3-15/16" 4-1/8" Inner iameter Inner iameter 3/8" (External view : 2-15/16"X3-15/16"X1-23/32") Inner iameter Note) onnection only to downstream units 4-7/32" Inner iameter Inner iameter (Inner iameter) (Outer iameter) Number of reducers 3/8" 2 1 7/8" 1 (Inner iameter) (Outer iameter) Number of reducers 1/4" 3/8" Outer iameter Outer iameter
12 MY-Y104-G For gas pipe: HEERS - IMENSIONS Ref.: W For liquid pipe: MY-Y108-G For gas pipe: Ref.: W For liquid pipe: MY-Y1010-G For gas pipe: Ref.: W For liquid pipe:
13 MY-Y64-G 1. Specification HEERS - IMENSIONS, contd. Ref.: 7FGF Main ccessory Items Number of ports Number of branch joints Pipe material Insulation material Reducer ap etails 3 ~ 4 ports One for each liquid and gas pipe Phosphorus deoxidized copper 1220T-OL (JIS H3300) Foamed polyethylene 7 reducers of 5 types 2 caps of 2 different types for each liquid and gas pipe ; 4 caps in total 2. External drawing For liquid pipe: Reducer (ccessory): 13-25/32" (Inner iameter) 3/8"(Inner iameter) 2-5/16" 13 /32" 4-13/32" 2-3/8" 2-3/8" 2-3/8" 2-3/8" 1-31/32" imension table Inner iameter Symbol (mm) 1/4" 3/8" (Inner iameter) (Outer iameter) Number of reducers 1 2 3/8" 1/4" 2 For gas pipe: 14-3/16" 7/8"(Inner iameter) (Inner iameter) 5-3/32" 19/32" 2-23/32" 25 /32" 2-3/8" 2-3/8" 2-3/8" 2-3/8" 2-3/8" imension table Inner iameter Symbol (mm) (Inner iameter) (Outer iameter) Number of reducers 1 3/8" 1 MY-Y68-G 1. Specification Ref.: 7FGF Main ccessory Items Number of ports Number of branch joints Pipe material Insulation material Reducer ap etails 5 ~ 8 ports One for each liquid and gas pipe Phosphorus deoxidized copper 1220T-OL (JIS H3300) Foamed polyethylene 3 reducers of 3 types 3 caps for each liquid and gas pipe ; 6 in total 2. External drawing For liquid pipe: 24- Insulation material (ccessory) (Inner iameter) Reducer (ccessory): 2-3/8" 2-3/8" 2-3/8" 2-3/8" 2-3/8" 2-3/8" 2-3/8" 2-15/16" 21-27/32" 2-1/ 16" 2-3/16" 4-9/16" 6-5/32" imension table Inner iameter Symbol (mm) 1/4" 3/8" (Inner iameter) (Outer iameter) Number of reducers 1 3/8" 1 For gas pipe: 24- Insulation material (ccessory) 2-3/8" 2-3/8" 2-3/8" 2-3/8" 2-3/8" 2-3/8" 2-3/8" 4-23/32" 23-7/8"(Inner iameter) (Inner iameter) 2-1/ 16" 2-5-1/16" 6-5/32" imension table Inner iameter Symbol (mm) (Inner iameter) (Outer iameter) Number of reducers 1
14 JOINT PTER KIT - IMENSIONS MY-R160-J The Joint kit include following items: 1 Instructions 2 Joint pipe 3 Joint pipe 4 over 1 5 over 2 6 over 3 7 and 8 Reducer (for liquid side) (for gas side) (for gas side) (for liquid side) 1pc 1pc 1pc 2pcs 1pc 1pc 8pcs 2pcs 2 Joint pipe (for liquid side) 3 Joint pipe (for gas side) (mm) 2-3/8"(60) 2-3/8"(60) MY-R160-J1 system so as to enable down-stream Indoor capacity above P80 as shown in Fig. 1. The Joint kit include following items: 1 Instruction 2 Joint pipe(small) 3 Joint pipe(large) 4 over 1 5 over 2 6 over 3 7 and 8 Reducer 1 9 Reducer 2 O19.05-I22.2 O19.05-I15.88 This sheet 1pc 1pc 1pc 2pcs 1pc for gas side 1pc for Iiquid side 8pcs 1pc 1pc Please prepare the following items in the field. 1 Tape for insulation material sealing 2 Extension pipe for refrigerant circuit 2 Joint pipe (for liquid side) 3 Joint pipe (for gas side) mm() ø9.52(3/8") ø9.52(3/8") 60(2-3/8") 9.05() 5.88() 60(2-3/8") ø9.52(3/8") 5.88() 226(8-29/32") 226(8-29/32") 1340 Satellite oulevard. Suwanee, G Toll Free: FORM# - ITY MULTI PIPE ESSORIES
PUHY-YMC. Air-Conditioners OUTDOOR UNIT FOR INSTALLER INSTALLATION MANUAL ENGLISH
ir-onditioners OUTOOR UNIT PUHY-YM FOR INSTLLR INSTLLTION MNUL For safe and correct use, please read this installation manual thoroughly before installing the air-conditioner. Remote controller (PR-F25M)
More information9001;2008 & , ADDENDUM
CITY MULTI Full Product Lineup Catalogue 2015 DDENDUM - Heat Pump Series NEW Y Ecostandard (P YK) ir conditioning is an ideal way of controlling the temperature, movement and cleanliness of air inside
More informationPUHY-P-YMF-B. Air-Conditioners OUTDOOR UNIT FOR INSTALLER FÜR INSTALLATEURE POUR L INSTALLATEUR VOOR DE INSTALLATEUR PER L INSTALLATORE
ir-onditioners OUTOOR UNIT geprü fte Sicherheit PUHY-P-YMF- FOR INSTLLR FÜR INSTLLTUR POUR L INSTLLTUR VOOR INSTLLTUR PR L INSTLLTOR INSTLLTION MNUL For safe and correct use, please read this installation
More informationAir-Conditioners For Building Application INDOOR UNIT CMB-WP108V-G
ir-onditioners For uilding pplication INOOR UNIT M-WP108V-G INSTLLTION MNUL For safe and correct use, please read this installation manual thoroughly before installing the air-conditioner unit. G 2 2.2
More informationAir Conditioning & Refrigeration Master Catalog. Catalog CIC /USA April 2003
ir onditioning & Refrigeration Master atalog atalog I-2003-1/US pril 2003 Table of ontents Table of ontents Introduction to Parker... page 77 System 5400 Series Self-Sealing Steel... page 78 5500 Series
More information120D, 150D, 190D, 240D, 370B. How to Order 220V 240V 400V 440V. Note 1) Select one applicable voltage. Voltage. Voltage. Symbol. Model 370B 220V 240V
Refrigerant R7 0, 0 90 I ir compressor Refrigerant 0kW kw 90kW kw Refrigerant R 70 I Refrigerant R7, R Series I Large 0,, 90,, 70 0 90 R7 Size 70 7 9 0 90 Three Voltage 7 9 Voltage 00/00 to 0V (/Hz) 0V
More informationAIR CONDITIONERS MODELS PQHY-P650YSHM-A PQHY-P700YSHM-A PQHY-P750YSHM-A PQHY-P800YSHM-A PQHY-P850YSHM-A PQHY-P900YSHM-A DATA BOOK
AIR CDITIERS MODELS PQHY-P6YSHM-A PQHY-P700YSHM-A PQHY-P7YSHM-A PQHY-P800YSHM-A PQHY-P8YSHM-A PQHY-P900YSHM-A DATA BOOK WY SERIES DATA G7 HEAT SOURCE UNITS I.WY SERIES. SPECIFICATIS... 2 2. EXTERNAL DIMENSIS...
More informationMitsubishi Electric's
3rd edition CONTENTS What is HYBRID CITY MULTI? - System Structure - 3 The reason why HYBRID CITY MULTI is unbeatable - Features - 4 - pplication example - 8 Mitsubishi Electric's Lineup 9 Specifications
More informationAir-Conditioners PUMY-SP112, SP125, SP140VKMD PUMY-SP112, SP125, SP140YKMD
ir-onditioners PUMY-SP112, SP125, SP140VKM PUMY-SP112, SP125, SP140YKM or use with R410 INSTLLTION MNUL OR INSTLLR or safe and correct use, read this manual and the indoor unit installation manual thoroughly
More informationOA Processing unit GUF-RD4, GUF-RDH4
Processing unit DT G GUFRD4, GUFRDH4 I. Processing unit. SPEIFITIOS... 27 2. SOUD EVES... 28 2. Measurement ondition... 28 22. curves... 28. F HRTERISTIS URVES... 29 4. EXTER DIMESIOS... 240 5. EETRI WIRIG
More informationTechnical and Dimensional Data. Saf-T Vent SC Plus
Technical and Dimensional Data Saf-T Vent S Plus 3"/5" & 4"/7" oncentric Reduced learance Double Wall for Special Gas Vent and/or Sealed ombustion Systems lso For Venting Listed Gas or Oil Fired ppliances
More informationPAC-AH125, 140, 250, 500M-J
ir Handling Unit ontroller P-H125, 140, 250, 500M-J FOR INSTLLR INSTLLTI MNUL For safe and correct use, please read this installation manual thoroughly before installing the controller. 2 [Fig. 2.0.1]
More informationWall-mounted air heaters for outdoor installation MEC EX C
all-mounted air heaters for outdoor installation for ducted outdoor installation wall-mounted air heaters have been specifically designed and certified for outdoor installation. he units are equipped with
More informationBuilding Comfort Solutions
Building Comfort Solutions Variable Refrigerant Flow Zoning Systems www.mehvac.com Mitsubishi Electric is a world leader in all types of quality products. Our consumer products, like high-definition televisions
More informationGHP OUTDOOR UNIT INSTALLATION INSTRUCTIONS E1 Combination Multi Type
621471-20E32 EN Always read before installation. Aisin Gas Heat Pump Air Conditioner GHP OUTDOOR UNIT INSTALLATION INSTRUCTIONS E1 Combination Multi Type Standard - Renewal [Model P450 - P560 - P710] Applicable
More informationBringing a year round comfort solutions to extreme climates
ooling or Heating ZUBDN series PUHYHP YHM(BS) PUHYHP YSHM(BS) Bringing a year round comfort solutions to extreme climates ITY MULTI ZUBDN series combines the ultimate in application flexibility and powerful
More informationSpecifica Copper tion Renewable ene Stainless rgy HOT WATER SOLUTIONS
opper Specification Renewable energy Stainless HOT WTER SOLUTIONS bout us Telford opper & Stainless ylinders is a family run business which began trading in 1989 from the premises it still occupies today
More informationPURY-WP-YJM-A (-BS) For use with R410A. Air-Conditioners For Building Application OUTDOOR UNIT
ir-onditioners For uilding pplication OUTOOR UNIT PURY-WP-YJM- (-S) For use with R410 INSTLLTION MNUL For safe and correct use, please read this installation manual thoroughly before installing the air-conditioner
More informationIDU22C, 22C1, 37C, 37C1, 55C, 75C
Refrigerated ir ryer Series IU edium IU, 1, 7, 71, 55, 75 () () () () () Run light Operation (ftercooler) Stop (ftercooler) Outlet air pressure gauge vaporation () (I) () Terminal block () () P rain port
More informationPAC-AH10A-G. Air Handling Unit Controller INSTALLATION MANUAL FOR INSTALLER
ir Handling Unit ontroller P-H10- OR NSTLLR NSTLLTON MNUL or safe and correct use, please read this installation manual thoroughly before installing the controller. 2 [ig. 2.0.1] 1 2 3 4 5 6 7 1 ontroller
More informationRefrigerated Air Dryer
T.S30-8 Refrigerated ir ryer Series IF/IU ir flow capacity Power consumption Refrigerant Increased up to the max. 40% ecreased up to the max. 40% F34a oefficient of destruction for ozone is zero. Improved
More informationAir-Conditioners OUTDOOR UNIT MXZ-8C140/160VAMD-A
ir-onditioners OUTOO UNIT MXZ-8140/160VM- HF utilized 410 INSTLLTION MNUL FO INSTLLE For safe and correct use, please read this installation manual thoroughly before installing the air-conditioner unit.
More informationTCB-DP22CUL. Drain Pump Kit. Model name : AIR CONDITIONER (SPLIT TYPE) Installation Manual. Installation Manual 2 Air Conditioner (Split type) English
AIR CONDITIONER (SPLIT TYPE) Model name : TCB-DP22CUL 2 Air Conditioner (Split type) English Manuel D installation Climatiseur (Type split) 12 Français Please read this carefully before installing the
More informationDiscrete type for different piping conditions VSH/VSU/VSB/VSC. Features
Discrete type for different piping conditions S/SU/S/SC Series Nozzle diameter: ø., ø., ø., ø., ø., ø. Different performance and shape are available to match different conditions. Features M M M This ejector
More informationSeries F61. Liquid Flow Switches. Feature and Benefits. T-body and Pipe-insert types available
PSC9720 European Refrigeration Controls Catalogue Catalog Section 3 Product Bulletin F61 Series F61 Liquid Flow Switches I ntroduction The F61 liquid flow switches can be used in liquid lines carrying
More informationTOYOTA FJ-40 DIRECTIONS
PAGE 1 TOYOTA FJ-40 DIRECTIONS Please read the following directions prior to installing this a/c system. Contact us by email or phone if you need any assistance or information regarding this a/c system.
More informationThe POWERTANK. Range by Pedrollo Distribution PACKAGED SOLUTION FOR BOOSTING WATER
The POWRTANK Range by Pedrollo istribution PAKAG SOLUTION OR OOSTING WATR POWRTANK Increased Water Pressure & low ompact esign Quiet & Reliable ase of Installation ry Run Protection Marked Product Applications
More informationDryer for semi-commercial laundry applications
ryer for semi-commercial laundry applications 10 eatures alvanized steel cylinder Top, front and side panels standard available in white oor opens 180 for easy loading and unloading Oversized lint filter
More informationSPLIT WALL-MOUNTED AIR CONDITIONER
SPLIT WALL-MOUNTED AIR CONDITIONER MODELS: WS 090C / WS 090H / WS00H EMAILAIR I N S T A L L A T I O N I N S T R U C T I O N S ACCESSORIES SUPPLIED WITH THE AIR CONDITIONER 2 LOCATION OF INDOOR AND OUTDOOR
More informationOur Latest Technologies
Full Product Lineup Catalogue 2015 Air conditioning is an ideal way of controlling the temperature, movement and cleanliness of air inside any building, large or small. With today's buildings being so
More informationKSGD-01W/S SEMI CONDUCTOR STAND ALONE REFRIGERANT LEAK DETECTOR. Instructions for :- KSGD-01W/S Semi Conductor Standalone Refrigerant Leak Detector
Issue 1 KSGD-01W/S SEMI CONDUCTOR STAND ALONE REFRIGERANT LEAK DETECTOR Installation Manual Instructions for :- For safe and correct use please read the installation manuals supplied with the equipment.
More informationInstallation Instructions
RE EFORE INSTLLING UNIT For SLO3 ir onditoner (8K~2K TU) To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed: ir conditioners
More informationHorizontal Scroll (Fixed speed)
Horizontal Scroll () ZS S Rated Output: W~,W Low Height due to Horizontal Type. % Lower ompared to Rotary Type, 55% Lower ompared to Reciprocating Type (7W) pplications: ommercial Refrigeration, Show ase
More informationINDEX. Air flow capacity SCFM (m 3 /h [ANR]) Model Outlet air pressure dew point Note) 37 F (2.8 C) 45 F (7.2 C) 50 F (10 C)
Refrigerated ir ryer Series IF For use in North, entral & South merica Protect Pneumatic quipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor,
More informationI ntroduction. Series F61. Liquid Flow Switches. Feature and Benefits
PSC9720 European Refrigeration Controls Catalogue Catalog Section 3 Product Bulletin F61 Series F61 Liquid Flow Switches I ntroduction The F61 liquid flow switches can be used in liquid lines carrying
More informationSubmittal Data Model AM Low Intensity Adaptive Modulating Infrared Heaters
Submittal ata Model M ow Intensity daptive Modulating Infrared Heaters Project Engineer ontractor Model # ate: Submitted by: pproved by: General Specification Fuel Type (heck one) Natural Gas PG Heat Exchanger
More informationSUBMITTAL DATA: MSZ-FH06NA & MUZ-FH06NA 6,000 BTU/H WALL-MOUNTED HEAT PUMP SYSTEM. Electrical Power Requirements. Indoor / Outdoor A 1 / 11
M-SERIES SUBMITTAL DATA: MSZ-FH0NA & MUZ-FH0NA,000 BTU/H WALL-MOUNTED HEAT PUMP SYSTEM Job Name: System Reference: Date: Electrical Power Requirements 08 / 30V, -Phase, 0 Hz ACCESSORIES: Unit Unit: MSZ-FH0NA
More informationACH1. Water Heating Unit Control Box INSTALLATION MANUAL FOR INSTALLERS
Water Heating Unit ontrol ox H1 FOR INSTLLRS INSTLLTION MNUL For safe and correct use, please read this installation manual thoroughly before installing the H1 control box. 0 2 [Fig. 2.1] 1 2 3 4 1 Thermistor
More informationWATER BATHS CONSTANT TEMPERATURE & IMMERSIBLE DEVICES
WTER BTHS CONSTNT TEMPERTURE & IMMERSIBLE EVICES Standard Water Baths Shaking Water Baths Immersible Circulators Stirrer Compatible Water Baths Multi-postition Water Baths Immersible Coolers Water Baths
More informationInstallation manual. Branch kit 1:3 RBC-TRP100E AIR CONDITIONER (SPLIT TYPE) Model name: Installation manual. Air conditioner (Split type) 1 English
EH99862001-2 AIR CONDITIONER (SPLIT TYPE) Installation manual Branch kit 1:3 Model name: RBC-TRP100E Installation manual Air conditioner (Split type) 1 English Please read this Installation Manual carefully
More information30RB /30RQ
AIR-OOLE LIQUI HILLER REVERSIBLE AIR-TO-WATER HEAT PUMP PRO-IALOG PLUS * Unit with low noise option 30RB9-80/30RQ0-46 Refrigerant HF-40A Nominal cooling capacity 93-78 kw Nominal heating capacity 7-0 kw
More informationResidential Fans & Air Purifiers
Residential Fans & ir Purifiers ESSORIES Fan ccessories Mounting lamps for Rigid Duct M mounting clamps are designed for use with rigid duct. The foam neoprene layer creates an air tight and solid installation
More informationInstallation Instructions READ BEFORE INSTALLING UNIT For SLO3 Air Conditoner (8,000~12,000 BTU)
RE EFORE INSTLLING UNIT For SLO3 ir onditoner (8,000~2,000 TU) INSTLLTION WRNINGS N UTION arefully read the installation manual before beginning. Follow each step as shown. Observe all local, state, and
More informationMODUCEL KW DOWNFLOW COOLING DRU DRU DATA ROOM UNITS
MOUEL 80-10 KW OWNFLOW OOLING RU RU T ROOM UNITS T ROOM UNITS The Moducel range of high efficiency ata Room Units, are designed for high density load areas where a large cooling duty is required from a
More informationAir-Conditioners INDOOR UNIT PEA-RP250 WHA INSTALLATION MANUAL
ir-onditioners NOOR UNT P-RP50 WH NSTLLTON MNUL or safe and correct use, please read this installation manual thoroughly before installing the air-conditioner unit. G 3 3. [ig. 3..] 800 50~00 00 00~300
More informationDURAVENT POLYPRO VENTING PRODUCTS
DURVENT POLYPRO VENTING PRODUCTS INDEX FLEX VENTING SYSTEM DPTER KIT... 14-11 -VENT RETROFIT DPTERS... 14-10 CHIMNEY CP... 14-10 CHIMNEY LINING KIT... 14-10 CHIMNEY SUPPORT... 14-11 COUPLER DPTER... 14-12
More informationCVS. Venting System for Category II, III, and IV gas appliances. Listed to UL-1738 and ULC S636.
VS Venting System for ategory II, III, and IV gas appliances. Listed to UL-1738 and UL S636. PelletVent venting system. Listed to UL 641, UL S609, and UL/ORD 441. Unitized venting system for DirectVent
More informationWater Jet Exhausters and Compressors
s and ompressors Single and Multi-Nozzle Types For vacuum pumping and mixing operations Schutte & Koerting water jet exhausters are simple, efficient and versatile devices for vacuum pumping or mixing
More informationDeluxe Oil-Filled Heater. Heating Capability: 1,000 sq. ft
Electric Heaters Electric Heater Fan apability: 800 sq. ft 750 / 1,500 / fan only 8387243 2.5 lb...21 eluxe Oil-Filled Heater apability: djustable thermostat. Safety tip-over switch. Swivel wheels for
More informationCompressors - Diesel Compressor CFM Compressor CFM Compressor CFM
IR QUIPMNT ompressors - iesel ompressor - 185 FM ompressor - 750 FM ompressor - 1600 FM NW 1600 FM ftercooled and filtered instrument quality air. 0.01 micron. Silenced, 76 dba ompressor - 1600 FM - Filtered
More informationQuestions on Installation? Call: GECARES (US) or Visit our Web site at: (US) 4" DUCT CLAMPS (2) OR 4" SPRING CLAMPS (2)
Installation Instructions Questions on Installation? Call: 1-800-GECARES (US) or Visit our Web site at: www.geappliances.com (US) Electric Dryer 49 37 BEFORE YOU BEGIN Read these instructions completely
More informationBrussels Recycling bin
1/7 Two wastes bin with top cover opening. ttractive double waste bin of high quality and performance 2 wastes station of 120 litres capacity (60 + 60 l.) Made from 1 mm cold rolled hot dip galvanized
More informationINDOOR UNIT PLFY-VAM / VCM PCFY-VGM PKFY-VAM / VGM / VFM PMFY-VBM
Y : PUHY R2 : PURY WY : PQHY WR2: PQRY S : PUMY INDOOR UNIT PLFY-VAM VCM PCFY-VGM PLFY-VLMD PKFY-VAM VGM VFM PMFY-VBM PFFY-VKM PEFY-VMS PFFY-VLRM VLEM PEFY-VMR Fresh Air Intake type PEFY-VML VMM VMH LONWORKS
More informationINVERTER SPLIT - TYPE
INVERTER SPLIT - TYPE ISSUE No 2 DATE 04/09/08 P/No 2020323A2868 CONTENTS SAFETY PRECAUTIONS Warning 2 Operating temperature 2 BEFORE INSTALLATION Tools needed for installation 3 Items required for installing
More informationECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION MEGATRON MODEL 10NB-LF 4 HOT & COLD INLETS 4 MIXED OUTLET 2 RETURN PIPING
4 4 5-4 3 8 4 4 5-3 8 4 TERMOSTATI 4 3 4 5-8 4 TERMO STATI TERMOSTATI 4 4 5-3 8 4 4-3 8 4 4 5 OMPLETE WATER TEMPERATURE ONTROL STATION EO-MIX Valve assemblies are ASSE 7 listed Submittal S-596Z-LF August,
More informationKFTC Series 18,000 to 48,000 Btu/h Cooling Only & Heat Pump INSTALLATION MANUAL
KFTC Series 18,000 to 48,000 Btu/h Cooling Only & Heat Pump INSTALLATION MANUAL INSTALLATION INSTRUCTIONS CEILING CASSETTE TYPE INDOOR UNIT Read this installation instructions carefully before installing
More informationHybrid VRF Next Generation 2-Pipe Heat Recovery Systems
Hybrid VRF Next Generation 2-Pipe Heat Recovery Systems HVRF YLM Series AN2.1 - NZ The Hybrid VRF Advantage "Water, rather than traditional refrigerant, is at the heart of the indoor units. This means
More informationTwin wall Air Gap Insulated Zalutite & Aluminium Commercial Gas Vent Chimney System
Q Twin wall ir Gap Insulated Zalutite & luminium ommercial Gas Vent himney System Designed for Individual and Modular Natural Draught Gravity Flow himney pplications PRODUT INFORMTION INTRODUTION Q is
More informationINSTALLATION INSTRUCTIONS
06-060 KMS0772-2472 ENG 3/17/06 2:50 PM Page a INSTLLTION INSTRUTIONS Inverter Multi Split System ir onditioner OOL/ RY Model This air conditioner uses the new refrigerant R410. For Outdoor Unit ontents
More informationINSTALLATION INSTRUCTION
INSTALLATION INSTRUCTION FLOOR /CEILING INDOOR UNIT MODEL: SMUL 12,18,24,30,36,48,60 Read this instructions carefully before installation. P. 12 P. 01 Dimemsion RHEEM REV 01 P. 02 P. 11 Detaching the mounting
More informationInstallation Manual MMU-AP0154SH-E MMU-AP0184SH-E MMU-AP0244SH-E AIR CONDITIONER (MULTI TYPE) Indoor Unit. Model name: 1-Way Cassette Type.
AIR CONDITIONER (MULTI TYPE) Indoor Unit Model name: 1-Way Cassette Type MMU-AP0154SH-E MMU-AP0184SH-E MMU-AP0244SH-E English SMMS 1-Way Cassette SH Type SMMS 1-Way Cassette SH Type 1 Original instruction
More informationADDENDUM INSTALLATION MANUAL
ADDENDUM INSTALLATION MANUAL System air conditioner RXYCQ4 RXYCQ RXYCQ RXYCQ RXYCQ40 RXYCQ4 RXYCQ RXYCQ RXYCQ RXYCQ40 Addendum Installation manual CONTENTS Page.. Optional accessories. Introduction.....
More informationRefrigerated Air Dryer
Refrigerated ir ryer Series For use in North, entral & South merica Protect Pneumatic quipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor, and
More informationMULTI HEAT PUMP PANEL CONSOLE TYPE DUCTLESS INVERTER INDOOR UNIT INSTALLATION MANUAL. Models: CH09MCU230VI CH12MCU230VI CH18MCU230VI
MULTI DUCTLESS INVERTER HEAT PUMP PANEL CONSOLE TYPE INDOOR UNIT INSTALLATION MANUAL Models: CH09MCU230VI CH12MCU230VI CH18MCU230VI Thank you for choosing a C&H Multi Ductless Heat Pump! You can feel confident
More informationPLA-ZRP35/50/60/71/100/125/140BA PLA-RP35/50/60/71/100/125/140BA
PL-ZRP35//6//1/1/14 PL-RP35//6//1/1/14 PLSERIES coplete line-up including deluxe units that offer added energy savings. The incorporation of wide air-outlet and the i-see Sensor enhances airflow distribution
More informationRefrigerated Air Dryers
Refrigerated ir ryers Protect Pneumatic quipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor, and prevents it from causing the pneumatic equipment
More informationDesign, Construct, and Operate to Control Indoor Humidity
EHUMIIFITION: Natatorium pplication & Product Guide esign, onstruct, and Operate to ontrol Indoor Humidity The Humidity Expert Munters is the world leader in dehumidification Munters is the largest manufacturer
More informationPrevents condensation
Moisture Control Tube Series Prevents condensation in piping for small cylinders/air grippers. Diffuses water vapor in the piping to the outside! Water vapor dditional power supply and works are not necessary!
More informationService Manual for RESmart CPAP V1.0. RESmart TM CPAP System. Service Manual
RESmart TM CPAP System Service Manual 1 Important All data in this manual have been verified correctly. It is sufficient for servicing and repairing this device. If applying this manual on other purpose,
More informationELECTRIC COOKTOP INSTALLATION INSTRUCTIONS INSTRUCTIONS D'INSTALLATION DE LA TABLE DE CUISSON ÉLECTRIQUE
LTRI OOKTOP INSTLLTION INSTRUTIONS INSTRUTIONS 'INSTLLTION L TL UISSON ÉLTRIQU Table of ontents / Table des matières OOKTOP STY... 1 INSTLLTION RQUIRMNTS... 2 Tools and Parts... 2 Location Requirements...
More informationPMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100
Ceiling cassette (-way flow type) RA Data G8 -P-VBM-E. SPECIFICATIONS - 98. EXTERNAL DIMENSIONS - 99 3. CENTER OF GRAVITY -. ELECTRICAL WIRING DIAGRAMS -. SOUND LEVELS -. Sound levels -. NC curve 6. TEMPERATURE/AIRFLOW
More informationInstallation Manual PMV Kit RBM-PMV0363E RBM-PMV0903E
EB99802801-1 Installation Manual RBM-PMV0363E RBM-PMV0903E Installation Manual English OUTDOOR UNIT SIDE UPPER INDOOR UNIT SIDE Thank you very much for purchasing TOSHIBA Air conditioner. Please read this
More informationRefrigerated Air Dryers
Refrigerated ir ryers /IU Series Protect Pneumatic quipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor, and prevents it from causing the pneumatic
More informationMultipoint. Unvented point of use hot water
Unvented point of use hot water Many different types of large commercial and industrial organisations need a reliable supply of hot water for up to 0 basins or sinks and we have developed the Multipoint
More informationVariable Refrigerant Flow (VRF) Systems
Variable Refrigerant Flow (VRF) Systems Flexible Solutions for Comfort Carrier Corporation Syracuse, New York January 2013 TABLE OF CONTENTS INTRODUCTION... 2 VRF TECHNOLOGY... 2 ADVANTAGES OF A VRF SYSTEM...
More informationTHF Series Industrial High Efficiency Filters
www.titusfilters.com TH Series Industrial High fficiency ilters and Save energy dollars protect your air system The ompressed ir hallenge, a government/ industry sponsored energy savings awareness program,
More informationInstallation Instructions
PAGE 1 Installation Instructions Important information about your new a/c system. Please read the following directions prior to installing this a/c system. PN: CK6772-1CHPU 1967-1972 Chevy PU A/C Kit Contact
More informationDigital Inverter 4 series 8 & 10HP
E6-H Digital Inverter 4 series 8 & 0HP High static duct type Indoor unit RAV-SM2244DTP-E RAV-SM2804DTP-E Outdoor unit RAV-SM2244AT8-E RAV-SM2804AT8-E Contents. Line up... 2. Indoor unit (High static duct
More information29" (73.7 CM) ELECTRIC DRYER INSTALLATION INSTRUCTIONS DRYER SAFETY
29" (73.7 M) LTRI RYR INSTLLTION INSTRUTIONS RYR STY...1 INSTLLTION INSTRUTIONS...1 Table of ontents...1 Tools and Parts...1 Location Requirements...2 lectrical Requirements...3 lectrical onnection...4
More information60 Hz. Catalogue_2016 REFRIGERATION UNITS. - Commercial Range -
60 Hz atalogue_2016 - ommercial Range - RERIGERTION UNITS ommercial monoblocks Tropicalized design for high ambient temperature up to 45º Thermostatic expansion valve Hot gas defrosting Refrigerant load
More informationProduct Dimensions Large Capacity Washing Machine Angled control W1113
Large apacity Washing Machine Angled control W1113 21 1/2" 23 1/2" W 22 1/2" D 33 3/8" - 34 1/8" 3 3/4" - 4 1/2" 2" D - 5 foot flexible drain hose connects lower left rear. - 208-240 Volt - 15 Amp 5 foot
More informationPUHZ-RP250YHM-A OUTDOOR UNIT. For use with R410A INSTALLATION MANUAL
OUTOOR UNIT PUHZ-RP250YHM- For use with R410 INSTLLTION MNUL For safe and correct use, please read this installation manual thoroughly before installing the air-conditioner unit. G 5 [Fig. 5.0.1] [Fig.
More informationVersa. Series. 96% Efficient. Versa-Hydro. Versa-Flame. Advanced Heating & Hot Water Systems
TP Made In merica dvanced eating & ot Water Systems Series ighly fficient, ombination, omestic ot Water and Space eating ppliances Up To 96% fficient TP Made In merica TP Made In merica TP Made In merica
More informationINSTALLATION MANUAL. Outdoor Unit. Indoor Unit FILE NO. A Cooling Only Model. Heat Pump Model. Heat Pump Model
FILE NO. A03-0 INSTALLATION MANUAL Unit MMU-AP009H, AP0H, AP05H, MMU-AP08H, AP04H, AP07H, MMU-AP030H, AP036H, AP048H MMU-AP056H MMU-AP007WH,
More informationSeries A28 Two stage Thermostats. Feature and Benefits
PSC9626 European Refrigeration Controls Catalogue Catalog Section 1 Product Bulletin A28 Series A28 Two stage Thermostats I ntroduction These thermostats are designed for various types of heating, cooling,
More informationESP. Variable Speed Heat Pump. Installation and Operation. 3 Ton ESP Ton ESP-60
Heating, ooling and Indoor Air Quality Systems ESP Variable Speed Heat Pump 3 Ton ESP-36 5 Ton ESP-60 Installation and Operation www.hi-velocity.com Module-VAR-Variable-Speed-Heat-Pump-060118 Installation
More informationCommercial Tankless Rack System
TNKLESS FREE STNDING IN-LINE LIGHTWEIGHT onstructed of anodized aluminum frame Utilizes the industry s lightest 199,000 TU high efficiency condensing tankless heater EXPNDLE Multiple design and installation
More informationcatalog variable refrigerant flow zoning systems FEATURING NEW CONTROLLERS MITSUBISHI ELECTRIC Cooling & Heating / CITY MULTI / 1
catalog variable refrigerant flow zoning systems Version I CMTECH_2.14 I 2014 Mitsubishi Electric US, Inc. I MITSUBISHI ELECTRIC Cooling & Heating / CITY MULTI / 1 FEATURING NEW CONTROLLERS PRODUCT GUIDE
More informationRefrigerated Air Dryer Large Size Series
Refrigerated ir Dryer Large Size Series E Directive compliant (with E marking) For use in Europe, sia and Oceania Power Three-phase 380 V (For sia and Oceania) supply voltage Three-phase 400 V (For Europe)
More informationWF Model Classic Washfountains Pre-Assembled Semi-Circular and Circular with 9" Deep Bowl
WF Model lassic Washfountains UP Approved Pre-Assembled owl and Pedestal Available in 5 or 36" iameter owl Size esigned for eavy uty and Washing Foot ontrol or Infrared Sensor Operation Available in or
More informationINSTALLATION INSTRUCTIONS 2WAY VRF System Air Conditioner
INSTALLATI INSTRUCTIS 2WAY VRF System Air Conditioner This air conditioner uses the refrigerant R40A. NOTE External diameter of service port R40A: 5/6" Model No. Type U Outdoor Units Outdoor Unit Type
More informationTW-Pro. Twin Wall Insulated Flue System EN T600 N1 W V2 L50040 G50 / O40
TW-Pro Twin Wall Insulated Flue System EN1856-1 T600 N1 W V2 L50040 G50 / O40 Approvals TW-Pro Twin Wall Insulated Flue System - TW-Pro has been specifically designed with the installer in mind with a
More informationInstallation/Care/Use Manual
Installation/Care/Use Manual EZH20 Surface Mount Bottle Filling Station IMPORTANT THIS IS AN INOOR APPLICATION ONLY! ALL SERVICE TO BE PERFORME BY AN AUTHORIZE SERVICE PERSONNEL. TOOLS/ITEMS REQUIRE BUT
More informationInstallation manual for room air conditioner
Installation manual for room air conditioner HSU-26HEK03/R2(D)/I HSU-35HEK03/R2(D)/I HSU-53HEK03/R2(D)/I HSU-71HEK03/R2(D)/I HSU-26HEK03/R2(D)/O HSU-35HEK03/R2(D)/O HSU-53HEK03/R2(D)/O HSU-71HEK03/R2(D)/O
More informationInstallation and Use Manual
Installation and Use Manual EMABFWS-RF and LMABFWS-RF Retrofit Bottle Filling Stations IMPORTANT THIS IS AN INDOOR APPLICATION ONLY. ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON. TOOLS REQUIRED
More informationRAV-SM567CTP-E RAV-SM807CTP-E RAV-SM1107CTP-E RAV-SM1407CTP-E RAV-SM1607CTP-E
AIR CONDITIONER (SPLIT TYPE) Installation Manual Unit Model name: For commercial use Ceiling Type RAV-SM567CTP-E RAV-SM807CTP-E RAV-SM1107CTP-E RAV-SM1407CTP-E RAV-SM1607CTP-E Installation Manual English
More informationWZT High Efficiency Air to Water Split System Heat Pumps With E.V.I. Compressors
High Efficiency ir to Water Split System Heat Pumps With E.V.I. ompressors -20 +43 +65 HP E.V.I..O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor
More informationInsty-Pac Steam Humidifiers
IP-1 Insty-Pac Steam umidifiers The PURE umidifier Co. Insty-Pac (patent no. 6,065,740) steam injection humidifier is jobengineered to assure highly efficient steam release into the air stream. Each humidifier
More informationDOMESTIC OUTLET. kg/cm 2 11 psi LEONARD LEONARD -10 C F LEONARD R THERMOSTATIC LEONARD LEONARD C F C F 60 COLD INLET HOT INLET
4 1-1 3 R 8 14 4 5 4 1 2 1 4 8 6 kg/cm 2 11 psi 8 1 1 1 14 1 4 ASSE 117 1-1 3 R 8 14 4 5 THERMOSTATI H 1 1 4 1-1 3 R 8 14 4 5 1 1 4 1-1 3 R 8 14 4 5 1 1 M-122Z September 1 MEGATRON MODEL 6N INSTALLATION
More informationInstallation Instructions. Revision Date: 05/16/12
Air-Cooled Condenser Installation Instructions Revision Date: 05/16/12 ! WARNING! These installation guidelines must be followed to obtain reliable operation from air-cooled ice machines. If these guidelines
More information