Fibre Optic Basics FIA Summer Seminar 2014
|
|
- Ralf Cross
- 5 years ago
- Views:
Transcription
1 Fibre Optic Basics FIA Summer Seminar 2014 Andrew Cole
2 Theory Basics Characteristics of Light What is Light? An electromagnetic wave, which like other waves, has a frequency (f), velocity (v) and a wavelength (λ). The velocity v, the speed of light is represented by c. c = f λ. 2
3 Theory Basics Characteristics of Light 3
4 Lasers and Eye Safety 4
5 Lasers and Eye Safety Visible Light Wavelength: 400nm to 700nm Typical Telecom Wavelength: 850nm to 1650nm Light used for communications is not visible light, but it will harm your eye Unless you are 100% sure that the light is switched off Never look into the end of an optical fibre 5
6 Unless you are 100% sure that the light is switched off Never look into the end of an optical fibre 6
7 Lasers and Eye Safety 7
8 Lasers and Eye Safety Video Inspection Probe / Indirect Viewing Aid 8
9 Unless you are 100% sure that the light is switched off Never look into the end of an optical fibre 9
10 Theory Basics Characteristics of Light Units of Measure Frequency: Wavelength: THz (x10 12 Hz or x10 6 GHz) (1550nm is approx. 292THz) um or nm (x10-6 m/s) nm (x10-9 m/s) Optical Power: dbm Attenuation: db Pulse Width: us or ns (x10-6 ) or ns (x10-9 ) 10
11 Theory Basics Characteristics of Light The Speed of Light c = 299,792,458 m/s (3 x 10 8 m/s Approximately) in a vacuum 11
12 Theory Basics Characteristics of Light But, light travels more slowly in any other material Index of Refraction (IOR), n (in fibre) n = c v (c = speed of light in a vacuum) (v = speed of light in the fibre) IOR is specified by the fibre manufacturer 12
13 Theory Basics Characteristics of Light The distance that light travels through an optical fibre, in a given time can be calculated d = c t n Where: d = distance c = the speed of light t =duration n = the Index of Refraction (IOR) 13
14 Theory Basics Characteristics of Light Core (glass) 8-10 microns SM 62.5 microns MM Cladding (glass) 125 microns Buffer / Coating 900 microns In a single mode fibre, not all the light energy is fully contained in the core of the fibre. Some of the light energy travels in the cladding, close to the core. The area of the beam of light, across a section of the fibre, is called the Mode Field or Effective Area and its diameter the Mode Field Diameter. The Core acts as a waveguide. Fibre Type Mode Field 1550nm MFD mid-range Effective Area (nominal) Dispersion compensating fibre um 6.1um 30um 2 G um 8.15um 52um 2 G.655 TW-RS um 8.4um 55um 2 G.655 LEAF um 9.6um 72um 2 G um 10.2um 83um 2 G.654.B um 11.25um 100um 2 14
15 How does an OTDR measure? 15
16 OTDR Basics Rayleigh Scattering Rayleigh Scattering Backscatter Particle Light pulse hits dopant particle Weaker after backscattering 16
17 OTDR Basics Time of Flight Fibre Core Reflection Light Pulse 17
18 OTDR Basics Time of Flight Light Pulse Reflection d = t c 2 n Where: d = distance c = speed of light in a vacuum t = elapsed time n = Index of Refraction 18
19 OTDR Basics OTDR Parameter Settings 19
20 OTDR Basics Pulse Width and Dynamic Range Too long (good DR but large deadzones) Just right (good DR, short deadzones) Too short (short deadzones but insufficient DR) 20
21 OTDR Basics Range Setting Range must be at least 25% greater than the fiber under test. If the OTDR stops measuring here... this data won t be acquired! 21
22 OTDR Basics OTDR Parameter Settings 22
23 OTDR Basics OTDR Trace 23
24 OTDR Basics Typical OTDR Trace Reflective Event Return Signal Level Launch Non-Reflective Event End/Fault Distance Noise 24
25 OTDR Basics - Deadzones Fusion splice Event Deadzone Backscatter Deadzone 25
26 OTDR Basics Reflectance Reflectance 26
27 OTDR Basics Loss & Reflectance P3 P1 P2 Insertion Loss P1 P2 (expressed in db) Reflectance P3 P1 (expressed in negative db, i.e. -40dB) Return Loss P1 P3 (expressed in positive db, i.e. +40dB) 27
28 OTDR Basics Optical Return Loss (ORL) ORL Fresnel Reflections Backreflections from Rayleigh Scattering Transmitted Light 28
29 Fibre Optic Cleanliness 29
30 Always clean before you connect!! 30
31 Always clean before you connect!! 31
32
Broadband System - H
Broadband System - H Satellites are spaced every 2nd degrees above earth "C" Band Toward satellite 6.0 GHz Toward earth 4.0 GHz "L" Band Toward satellite 14.0 GHz Toward earth 12.0 GHz TV TRANSMITTER Headend
More informationOPTICAL TIME DOMAIN REFELECTOMETER (OTDR): PRINCIPLES
OPTICAL TIME DOMAIN REFELECTOMETER (OTDR): PRINCIPLES Why Test Fiber with an OTDR? Single ended test that......characterizes fiber from end-to-end...locate and measure each event...provides a detailed
More informationGAMMA OTDR application consists of main window and menu. Using menu user can operate in different modes of application.
GAMMA OTDR Introduction...1 Using GAMMA OTDR...1 Application main window...1 Menu description...2 file...2 instrument...2 mode...5 events...9 view...11 Introduction GAMMA OTDR is the first Android application
More informationVTI Services Technical Bulletin (TB) OTDR Measurement of Installed Optical Fibre Cabling Permanent Links and Links
VTI Services Technical Bulletin (TB) OTDR Measurement of Installed Optical Fibre Cabling Permanent Links and Links TB Number 004 This bulletin is supplied for information only and is intended to provide
More informationFiber Optics for Todays Industry Applications
Hands-On Fiber Optics for Todays Industry Applications (A Non-Telephone Company Course) Course Description This Hands-On course is designed to provide technicians with a practical understanding and Hands-On
More informationFiber Optic and CAT 5, 6, 7 and 8 Installer Premise Cabling
Hands-On Fiber Optic and CAT 5, 6, 7 and 8 Installer Premise Cabling Certification Course Description This Hands-On course is customized to give Technicians the confidence and skills to maintain Fiber
More informationPC474 Lab Manual 1. Terry Sturtevanta and Hasan Shodiev 2. Winter 2012
PC474 Lab Manual 1 Terry Sturtevanta and Hasan Shodiev 2 Winter 2012 1 Much of this information is taken from OptoSci documentation 2 with much original material by Adam Prescott Contents 1 OTDR (Optical
More informationEnsuring Cabling Performance in the Customer-Owned Outside Plant. Keith Foord Product Manager Greenlee Communications
Ensuring Cabling Performance in the Customer-Owned Outside Plant Keith Foord Product Manager Greenlee Communications Introduction: Outside plant fiber networks require low reflectance terminations for
More informationEnsuring Cabling Performance in the Customer-Owned Outside Plant
Ensuring Cabling Performance in the Customer-Owned Outside Plant Needs to be able to qualify the installation to validate bandwidth requirements are met Future high bandwidth applications Future Proof
More informationTable of Contents. Introduction... 1 Fiber Optic Communications... 1 Testing Optical Fiber For Loss... 2 Other Fiber Tests... 2 OTDR Applications...
Understanding OTDRs For more information on OTDRs or testing of fiber optic systems please contact your local GN Nettest-Optical Division representative or call the GN Nettest Help Line at 800-443-6154
More informationPC474 Lab Manual Wilfrid Laurier University 1
PC474 Lab Manual Wilfrid Laurier University 1 c Dr. Hasan Shodiev and Terry Sturtevant 2 3 Winter 2018 1 Much of this information is taken from OptoSci documentation 2 with much original material by Adam
More informationOPTICAL TIME DOMAIN REFLECTOMETRY (OTDR) Dr. BC Choudhary Professor, NITTTR, Chandigarh
OPTICAL TIME DOMAIN REFLECTOMETRY (OTDR) Dr. BC Choudhary Professor, NITTTR, Chandigarh WHAT IS AN OTDR? A measurement technique which provides the loss characteristics of an optical link down its entire
More informationHands-On Fiber Optics ISP/OSP - Advanced Combo- Tech
Hands-On Fiber Optics ISP/OSP - Advanced Combo- Tech Course Description This Hands-On 3-day course has been customized to provide technicians with a practical understanding of fiber optic theory and fiber
More informationThe Optical Time Domain Reflectometry and the Fusion Splicer Laboratory exercise
The Optical Time Domain Reflectometry and the Fusion Splicer Laboratory exercise 1 The purpose of the exercise...2 2 Background...2 2.1 Introduction to scattering and attenuation...2 2.2 Introduction to
More informationFLX380-30x FlexTester OTDR
Features 3rd generation hand-held, all-in-one OTDR, Source, Power Meter, VFL Icon-based LinkMap display with pass/fail for easy network analysis Patented in- or out-of-service testing from a single port
More informationDWDM OTDR with Tunable Laser MTP-200-D100. Hand-held High Performance OTDR. Series
MTP-200-D100 Hand-held High Performance OTDR DWDM OTDR with Tunable Laser Series Multi-Function and High Performance OTDR Testing 96 C-band wavelengths Dynamic range up to 38dB Short zone: EDZ 1m, ADZ
More informationHands-On Fiber Optic ISP / OSP Combo-Tech Splicing, Termination & Testing
Hands-On Splicing, Termination & Testing BICSI CECs This course has been approved for CEC credits by BICSI. Please read below for a breakdown of the credits that we offer for this course. For more information
More informationIDEAL INDUSTRIES, INC. USER MANUAL IDEAL OTDR
IDEAL INDUSTRIES, INC. USER MANUAL IDEAL OTDR Revision: March 31, 2016 Copyright 2013 2016 EXFO Inc. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system or
More informationpalmotdr Series Handheld OTDR
palmotdr Series Handheld OTDR Most Compact High-Performance OTDR Comprehensive fiber applications, ideal for LAN/WAN/FTTx certification & trouble-shooting: SM: 1310/1490/1550, 1625/1650nm (with filter),
More informationHigh cost performance choice
GRANDWAY FHO000 series OTDR High cost performance choice FEATURES APPLICATIONS Hand-held and portable CATV network testing High cost performance Access network testing 5-inch HD touch screen LAN/WAN network
More informationOTDR. Optical Time Domain Reflectometer. User Guide
OTDR Optical Time Domain Reflectometer User Guide Copyright 2013 2015 EXFO Inc. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system or transmitted in any form,
More informationA. General: Horizontal and backbone cabling shall be verified in accordance with ANSI/TIA/EIA-568-C and the addendum for fiber optic testing.
3.4 TESTING OF FIBER OPTICS CABLING A. General: Horizontal and backbone cabling shall be verified in accordance with ANSI/TIA/EIA-568-C and the addendum for fiber optic testing. B. General: In the event
More informationHands-On CAT 5/6 & Fiber Optic Installer
Hands-On BICSI CECs This course has been approved for CEC credits by BICSI. Please read below for a breakdown of the credits that we offer for this course. For more information regarding BICSI please visit
More informationFli'l HEWLETT. Measurement of Raylelgh Backscattering at 1.55 urn with a 32 um Spatial Resolution
Fli'l HEWLETT a:~ PACKARD Measurement of Raylelgh Backscattering at 1.55 urn with a 32 um Spatial Resolution W. V. Sorin, D. M. Baney Instruments and Photonics Laboratory HPL-91-180 December, 1991 Rayleigh
More informationOmnisens DITEST TM FIBER OPTIC DISTRIBUTED TEMPERATURE & STRAIN SENSING TECHNIQUE
1 Omnisens DITEST TM FIBER OPTIC DISTRIBUTED TEMPERATURE & STRAIN SENSING TECHNIQUE Introduction Omnisens DITEST (Distributed Temperature and Strain sensing) is a distributed temperature and/or strain
More informationHigh cost performance choice
ООО "Техэнком" Контрольно-измерительные приборы и оборудование www.tehencom.com G R A N D W A Y F H O 0 0 0 s e r i e s O T D R High cost performance choice FEATURES APPLICATIONS Hand-held and portable
More informationRLH Industries, Inc. Cleaning and Testing Fiber Optic Cable. Reference Guide MD A 0507
RLH Industries, Inc. Cleaning and Testing Fiber Optic Cable Reference Guide MD-019 2014A 0507 RLH Industries, Inc. Copyright 2013 RLH Industries, Inc. All rights reserved. No part of this document may
More informationOptical Time Domain Reflectometry (OTDR)
Experimental Optics Contact: Helena Kämmer (helena.kaemmer@uni-jena.de) Last edition: Helena Kämmer, January 2017 Optical Time Domain Reflectometry (OTDR) Contents 1 Overview 3 2 Safety issues 3 3 Theoretical
More informationpalmotdr Series Handheld OTDR
palmotdr Series Handheld OTDR Most Compact High-Performance OTDR Comprehensive fiber applications, ideal for LAN/WAN/FTTx certification & trouble-shooting: SM: 1310/1490/1550, 1625/1650nm (with filter),
More information4120 Fire Alarm Network Reference
4120 Fire Alarm Network Reference Features Autocall 4120 Fire Alarm Network communications are available for wired or fiber optic connections Wired communications are available on Network Interface Cards
More informationNoyes OFL 250B Specs Provided by
Noyes OFL 250B Specs Provided by www.aaatesters.com OFL 250 Handheld OTDR The Noyes OFL 250 from AFL Telecommunications is a single-mode OTDR with an integrated Optical Power Meter (OPM), Source (OLS),
More informationiotdr Series Portable OTDR Test Set iotdr Series OTDR Tester is entirely new portable product released by OPWILL.
www.opwill.com OTDR Tester is entirely new portable product released by OPWILL. Adopting Bluetooth technology allows engineers to conduct the test remotely on their portable Windows, or Android devices.
More informationFLX380 and OFL280 FlexTester Series
FLX380 and OFL280 FlexTester Series User Guide www.aflglobal.com or +1 (800) 321-5298, +1 (603) 528-7780 Contents Safety Information... 4 General Information... 5 Contacting Customer Service...5 Recommended
More informationMTTplus Modular Test Platform
MTTplus-410 Fiber Optics Test Module 2017 MTTplus Modular Test Platform The Fiber Optics module for the VeEX MTTplus supports a full range of test functions including OTDR, OPM, Light Source and VFL. Geo
More informationVIEW500 USER-FRIENDLY STANDARD OTDR
USER-FRIENDLY STANDARD OTDR SOLA (Smart Optical Link Analyzer) 7 Touch Screen with Smart GUI 8GB Internal Storage with Internal SD Card & External USB Memory Built-In VFL, Light Source and OPM Fast Booting
More informationFibre Specification Standards
Fibre Specification Standards User Manual The most important thing we build is trust Cobham Wireless - Coverage Table of Contents 1. Single-mode Fibre to ITU-T Recommendation G.652 3 2. SC/APC Mated Pair
More informationM700-Series Multifunction OTDR
M700-Series Multifunction OTDR Test, Troubleshoot and Document Single-mode and Multimode Fiber Networks Test Modes Full Auto OTDR Normal (point-to-point) fiber cable construction testing and fault location
More informationRAMAN SCATTERING AND OTDR BASED DISTRIBUTED SENSOR FOR TEMPERATURE MONITORING APPLICATIONS
RAMAN SCATTERING AND OTDR BASED DISTRIBUTED SENSOR FOR TEMPERATURE MONITORING APPLICATIONS Sait Eser KARLIK Uludağ University Faculty of Engineering and Architecture Department of Electronics Engineering
More informationDistributed Temperature Sensing
Distributed Temperature Sensing Distributed Temperature Sensing (DTS) Introduction The purpose of this paper is to acquaint the engineer with the technology, terms and physical principles of Distributed
More informationPRO Android OTDR. Android Enabled OTDR. For Use With: PRO-2, PRO-3, PRO-FBE-300
PRO Android OTDR Android Enabled OTDR For Use With: PRO-2, PRO-3, PRO-FBE-300 Table of Contents Chapter Page 1 Using This Manual 1 2 Safety 2 3 Android Quick Start Guide 4 4 Introduction 6 5 OTDR Inspection
More informationWHITE PAPER FIBER OPTIC SENSING. Summary. Index. Introduction. About Fischer Connectors
Summary This white paper presents the technical basics behind sensing over fiber technologies, its main applications and the cabling solutions involved. Index By: Jacques Miéville, Project Manager, Fischer
More informationOTDR - FHO5000-xxx. Optical Time Domain Reflectometer
OTDR - FHO5000-xxx Optical Time Domain Reflectometer FHO5000 series Optical Time Domain Reflectometer (OTDR) is the latest generation of intelligent instrument for test and detection of fiber optic communication
More informationVIEW500. Please read this manual before operating the device. Please keep this manual together with the device. 2017/07 Rev.0.2
VIEW500 Please read this manual before operating the device. Please keep this manual together with the device. 2017/07 Rev.0.2 VIEW500 User Manual 1 2 Important: INNO Instrument strongly recommends all
More informationFTS500 Series. Handheld OTDR Test Set.
www.opwill.com OTDR Tester is entirely new pad product released by OPWILL. It has rapid start technology and supports automatic and realtime test mode, which can guarantee engineers to examine and detect
More informationDetection of Solvents using a Distributed Fibre Optic Sensor
Detection of Solvents using a Distributed Fibre Optic Sensor Alistair MacLean, Chris Moran, Walter Johnstone, Brian Culshaw, Dan Marsh, Paul Parker. A fibre optic sensor that is capable of distributed
More informationAE3100A~M Series 2-and 4-Wavelength Handheld OTDR
Key Features High performance OTDR for FTTx and RFoG networks 7, 800x480 LCD touchscreen places power and convenience at your fingertips Excellent short-distance performance with 0.8m event dead zone and
More informationField Testing and Troubleshooting of PON LAN Networks per IEC Jim Davis Regional Marketing Engineer Fluke Networks
Field Testing and Troubleshooting of PON LAN Networks per IEC 61280-4 Jim Davis Regional Marketing Engineer Fluke Networks Agenda Inspection and Cleaning APC vs UPC PON basics Wavelengths Architecture
More informationFiber optic distributed pressure sensor for structural monitoring applications
Fiber optic distributed pressure sensor for structural monitoring applications S. Binu *a, V.P. Mahadevan Pillai a, N. Chandrasekaran b a Department of Optoelectronics, University of Kerala, Thiruvananthapuram-695581,
More informationFibre (TIA) Field Test Specification
This document has been prepared to aid consultants or engineers in developing contractual specifications covering the testing of duplex fibre optic cabling installations. It is offered as a general guide.
More informationField Test Procedure for Optical Fibre Link Measurements
Application Notes Field Test Procedure for Optical Fibre Link Measurements Issued April 2014 Abstract After fiber optic cables are installed, spliced and terminated, they must be tested. For every fiber
More informationReflectance, The Hidden Danger That Increases Bit Error Rates in Your Fiber Networks Denver, May 22nd, 2010
Reflectance, The Hidden Danger That Increases Bit Error Rates in Your Fiber Networks Denver, May 22nd, 2010 Adrian Young Sr. Customer Support Engineer Foreword Reflectance is measured using an Optical
More informationM310 Enterprise OTDR. Designed for Enterprise Network Testing, Troubleshooting and Documentation. or (800) , (603)
Designed for Enterprise Network Testing, Troubleshooting and Documentation Features Industry leading TruEvent analysis Short dead zones provide precise testing of closely spaced events Front Panel and
More informationDR-500 Series Handheld OTDR User Guide
DR-500 Series Handheld OTDR User Guide 19 Norfolk Ave * Easton * MA * USA * 02375 - Phone: 508.238.7100 * Fax: 617.507.0784 1 Table of Contents I 1. General Information 2. Safety Information 3. Introduction
More informationA Fresnel Reflection-Based Optical Fiber Sensor System for Remote Refractive Index Measurement Using an OTDR
PHOTONIC SENSORS / Vol. 4, No. 1, 2014: 48 52 A Fresnel Reflection-Based Optical Fiber Sensor System for Remote Refractive Index Measurement Using an OTDR Jianying YUAN, Chunliu ZHAO *, Manping YE, Juan
More informationA dvan ced Fib er Opt ic Test Eq u ip me nt Terahertz Technologies Inc.
A dvan ced Fib er Opt ic Test Eq u ip me nt Terahertz Technologies Inc. 1-888-U.S.-OTDRS www.teratec.us sales@teratec.us 169 Clear Rd. Oriskany, NY 13424 Domestic: 1-888-876-8377 TERAHERTZ TECHNOLOGIES
More informationFIA. The Fibreoptic Industry Association. TECHNICAL SUPPORT GUIDE FIA-TSD
FIA The Fibreoptic Industry Association www.fibreoptic.org.uk TECHNICAL SUPPORT GUIDE FIATSD000 TESTING INSTALLED CABLING USING OPTICAL TIME DOMAIN RELFECTOMETER (OTDR) EQUIPMENT This document has been
More informationClearlite Photonic Fibers
Clearlite Photonic Fibers Fiber Name Operating Wavelength MFD at Operating Wavelength Beat Length at Operating WL Clad/Coating Diameter Order by Part Number TruePhase 980 Micro TruePhase 980 400 TruePhase
More informationSumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber. PureGuide SM Optical Fiber, TIA Type IVd. Issued: November 2003
Sumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber PureGuide SM Optical Fiber, TIA Type IVd Issued: November 2003 78 Alexander Drive, Research Triangle Park, NC 27709 Phone
More informationFibre Characterisation and FTTx New challenges
Fibre Characterisation and FTTx New challenges Broadband Technology Event Rotterdam, November 10th, 2009 Nicolas CARLIER France & Benelux RSM nicolas.carlier@exfo.com What is Fiber Characterisation when
More informationSumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber
Sumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber PureGuide -LA SM Optical Fiber, TIA Type IVd ITU G.655 C and D Compliant Issued:
More informationTerahertz Technologies Inc Fiber Optic Test Equipment Catalog
Terahertz Technologies Inc. 2011 Fiber Optic Test Equipment Catalog Advanced F/O Test Equipment OTDRS Power Meters Light Sources And Loss Test Sets Terahertz Technologies Inc. 169 Clear Rd., Oriskany NY
More informationAdvanced Fiber Optic Test Equipment Terahertz Technologies Inc.
Advanced Fiber Optic Test Equipment Terahertz Technologies Inc. 1-888-U.S.-OTDRS www.teratec.us sales@teratec.us 169 Clear Rd. Oriskany, NY 13424 1-888-876-8377 315-736-3642 FT E-7500A OTDR Onboard Help
More informationCorrelation-based OTDR for in-service monitoring of 64-split TDM PON
Correlation-based OTDR for in-service monitoring of 64-split TDM PON H. K. Shim, K. Y. Cho, Y. Takushima, and Y. C. Chung* Department of Electrical Engineering, Korea Advanced Institute of Science and
More informationHELKAMA. Optical Fibre Cables
1 Contents Optical fibres and their characteristics Cable constructions Cable tests Installation, jointing and terminating Manufacturing (pictures) 2 Multimode Fibre (GK) Attenuation and Bandwidth Fibre
More informationOptical Return Loss Measurement by Gregory Lietaert, Product Manager
White Paper Optical Return Loss Measurement by Gregory Lietaert, Product Manager Introduction With the increasing frequency of high-speed transmission systems and DWDM deployment, optical return loss (ORL)
More informationM700-Series OTDRs. or (800) , (603)
Features M700 Compact QUAD OTDR M700 OTDR with DFS1 Digital FiberScope Integrated OPM and VFL (650 nm) Inspection capable with the DFS1 FiberScope Full Auto, Expert, and Real-Time OTDR test modes Automatic
More informationExtensive range of models covering all telecom testing applications. Flexible design, allowing up to three wavelengths in a single module
7000 OTDR MODULE SERIES NETWORK TESTING The all-new FTB-7000D: first-class benefits 1 m event dead zone: shortest in the industry Testing time: four times shorter than industry standard FTTx ready: passive
More informationAgilent E6000A E6003A Specs Provided by E6000C Mini-OTDR. Technical Data Sheet
Agilent E6000A E6003A Specs Provided by www.aaatesters.com E6000C Mini-OTDR Technical Data Sheet Specifications describe the instrument s warranted performance, measured with typical PC-type connectors.
More informationBasic Professional Fiber Optic Installation
Basic Professional Fiber Optic Installation QUICK SUMMARY Length: 32 hours; or 40 hours with Fiber Optic Association CFOT certification Hands-on Activities: 40 activities, 70-75 % Text/Field Reference:
More informationLAN/WAN OTDR FTB-7200 FTTx Access/Metro OTDR FTB-7200/7300 Metro/Long-Haul OTDR FTB-7400/74000 Long-Haul OTDR FTB-7500
OTDR MODULE SERIES LAN/WAN OTDR FTB-7200 FTTx Access/Metro OTDR FTB-7200/7300 Metro/Long-Haul OTDR FTB-7400/74000 Long-Haul OTDR FTB-7500 NETWORK TESTING OPTICAL Platform Compatibility First-class benefits
More informationFTB-700 Series. OTDR for FTB-1. User Guide
FTB-700 Series OTDR for FTB-1 User Guide Copyright 2006 2011 EXFO Inc. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system or transmitted in any form, be it
More informationFlexScan OTDR With SmartAuto and LinkMap
FlexScan OTDR With SmartAuto and LinkMap Quick Reference Guide Test & Inspection Controls, Display, Interfaces 1 2 4 8 1. Power button 2. Power jack (5 VDC) 3. Charge/AC indicator 4. USB ports 5. OTDR/source
More informationMINI2. Inno Mini 2 Specs Provided by MOST ACCURATE COMPACT OTDR
Inno Mini 2 Specs Provided by www.aaatesters.com MOST ACCURATE COMPACT OTDR SOLA (Smart Optical Link Analyzer) 5 Touch Screen with Smart GUI 8GB Internal Storage with Internal SD Card & External USB Memory
More informationAgilent E6012A Specs Provided by E6000C Mini-OTDR. Technical Data Sheet
Agilent E6012A Specs Provided by www.aaatesters.com E6000C Mini-OTDR Technical Data Sheet Specifications describe the instrument s warranted performance, measured with typical PC- type connectors. Uncertainties
More informationFLX380-30x FlexTester3 OTDR
Features 3rd generation hand-held, all-in-one OTDR, OLS, OPM, VFL Patented in- or out-of-service testing from a single port 42/42 db dynamic range @ 1310/1550 nm; test up to 1x128 PON Industry-leading
More informationGRANDWAY FHO5000 series OTDR
GRANDWAY FHO5000 series OTDR Convenient multi-function fiber optic tester Design for tough outdoor environment FEATURES Integrated design, smart and rugged IP65 protection level, outdoor enhanced 7-inch
More informationM210 Multifunction Micro OTDR
Test, Troubleshoot and Document Single-mode and Multimode Fiber Networks Features 30 db dynamic range single-mode 16-hour battery life Remote display capable Touch and Test intuitive user interface New
More informationFHO5000 Series Triple-Proof OTDR
FHO5000 Series Triple-Proof OTDR Description FHO5000 series OTDR is specially designed for tough outdoor jobs. IP65 protection level, lightweight, easy operation, lowreflection LCD and more than 12 hours
More informationM210 Multifunction Micro OTDR
Test, Troubleshoot and Document Single-mode and Multimode Fiber Networks Features 30 db dynamic range single-mode 16-hour battery life Remote display capable Touch and Test intuitive user interface New
More informationFTS510 Series. Handheld OTDR Test Set.
www.opwill.com FTS510 Series FTS510 Series OTDR Tester is entirely new pad product released by OPWILL. It has rapid start technology and supports automatic and realtime test mode, which can guarantee engineers
More informationLuna Technologies Webinar Series. New Rayleigh-Based Technique for Very High Resolution Distributed Temperature and Strain Sensing
Luna Technologies Webinar Series New Rayleigh-Based Technique for Very High Resolution Distributed Temperature and Strain Sensing Dr. Dawn Gifford Senior Optical Engineer Mr. Ed Valigursky VP of Sales
More informationASSMANN ELECTRONIC GmbH ASSMANN SYSTEM GUARANTEE. DIGITUS Professional Fiber Optic Cabling System. Appendix B - Provisions for acceptance
ASSMANN ELECTRONIC GmbH ASSMANN SYSTEM GUARANTEE DIGITUS Professional Fiber Optic Cabling System Appendix B - Provisions for acceptance Page 1 Table of contents 1. Acceptance test of the installation link
More informationFTBx-740C-DWC TUNABLE OTDR C-BAND DWDM METRO ETHERNET LINK CHARACTERIZATION
C-BAND DWDM METRO ETHERNET LINK CHARACTERIZATION GLOBAL PORTABLE FIBER OPTIC TEST EQUIPMENT MARKET LEADERSHIP AWARD NEW OTDR GENERATION Tunable DWDM OTDR for testing through MUX/DEMUX channels to provide
More informationOPTICAL TIME-DOMAIN REFLECTOMETER
Tallinn University of Technology Laboratory exercise 1 of Fiber Optical Communication course OPTICAL TIME-DOMAIN REFLECTOMETER Tallinn 2016 Aim of the laboratory exercise: The aim of this laboratory exercise
More informationOTDR II. Tier-2 Optical Time Domain Reflectometer for Multimode and Single-mode Fiber Cabling
Tier-2 Optical Time Domain Reflectometer for Multimode and Single-mode Fiber Cabling Tier-2 Optical Time Domain Reflectometer for Multimode and Single-mode Fiber Cabling The OTDR II is the first tablet
More informationDEGRADATION OF OPTICAL FillERS AT CARBON-CARBON PYROLYSIS. Rockwell International Science Center P.O. Box 1085 Thousand Oaks, CA 91358
DEGRADATION OF OPTICAL FillERS AT CARBON-CARBON PYROLYSIS TEMPERATURES Jeffrey S. Schoenwald Rockwell International Science Center P.O. Box 1085 Thousand Oaks, CA 91358 INTRODUCTION The value of having
More informationFACULTY OF ENGINEERING LAB SHEET OPTICAL COMMUNICATION SYSTEMS EOP4066 TRIMESTER 1 (2013/2014)
FACULTY OF ENGINEERING LAB SHEET OPTICAL COMMUNICATION SYSTEMS EOP4066 TRIMESTER 1 (2013/2014) OC1 FIBER LINK CHARACTERIZATION WITH OTDR *Note: On-the-spot evaluation may be carried out during or at the
More informationEnsuring the Health of Tomorrow s Fiber LANs Part II OTDR Trace Analysis Become an Expert Troubleshooter with Advanced OTDR Trace Analysis
Ensuring the Health of Tomorrow s Fiber LANs Part II OTDR Trace Analysis Become an Expert Troubleshooter with Advanced OTDR Trace Analysis Experience designing cable and network testers has enabled a breakthrough
More informationEvent dead zone: 0.8 m. Attenuation dead zone: 4 m. Dynamic range: up to 50 db. Platform compatibility. FTB-200 Compact Platform
OTDR MODULE SERIES FTB-7000 OTDR Series NETWORK TESTING OPTICAL Powerful OTDRs covering all network testing applications Event dead zone: 0.8 m Attenuation dead zone: 4 m Dynamic range: up to 50 db FTTx
More informationAccelerating NBN fiber testing. Tom Ronan Marketing Lead Fiber Optics Melbourne
Accelerating NBN fiber testing and workforce Performance. Tom Ronan Marketing Lead Fiber Optics Melbourne Agenda Network Elements and Parameters Distributed Fiber Network (DFN) Construction Network Activation
More informationFiber Tes)ng 101 Essen)als Every Network Analyst Needs to Know. David S(llwell BCNET Oscar Rondon BCNET Gwenn Amice - EXFO
Fiber Tes)ng 101 Essen)als Every Network Analyst Needs to Know David S(llwell BCNET Oscar Rondon BCNET Gwenn Amice - EXFO Workshop format The Workshop is going to start with three short lecture style power
More informationVIEW500 FASTEST STANDARD OTDR
FASTEST STANDARD OTDR SOLA, Simplify The OTDR Test Process 7 Touch Screen with Smart GUI 8GB Internal Storage with Internal SD Card & External USB Memory Built-In VFL, Light Source and OPM Fast Booting
More informationAV6416 OTDR. Product Overview: Main Features:
AV6416 OTDR Product Overview: AV6416 OTDR is a test instrument designed for FTTx. It s mainly used to measure the physical characteristics of optical fiber & cables, including length, transmission loss
More informationFIBER OPTIC TESTING JIM HAYES OVERVIEW
C H A P T E R 17 FIBER OPTIC TESTING JIM HAYES OVERVIEW Testing fiber optic components and systems requires making several basic measurements. The most common measurement parameters are shown in Table
More informationTable of Contents 1Q08. Test & Inspection
Table of Contents Optical Time Domain Reflectometers (OTDR) M700 Compact Single-mode OTDR....................... 3 M200 Handheld OTDR... 5 OFL-250 Handheld OTDR.... 7 OFL-200 Single-mode OTDR............................
More informationACCESS Master MT9085 Series. Product Introduction
ACCESS Master MT9085 Series Product Introduction Strengthen of MT9085 Series: 1/5 All Optical Fiber Evaluation Functions in One Tester The ACCESS Master MT9085 series is an all-inone tester with OTDR,
More informationTerahertz Technologies Inc.
Advanced Fiber Optic Test Equipment Terahertz Technologies Inc. 1-888-U.S.-OTDRS www.teratec.us sales@teratec.us 169 Clear Rd. Oriskany, NY 13424 Domestic: 1-888-876-8377 International: 315-736-3642 Mission
More informationFibrlok II 2529 Universal Optical Fiber Splice
Fibrlok II 2529 Universal Optical Fiber Splice Technical Report December 1994 Issue 1, 78-8098-3415-9 1 1.0 Product Description The 3M brand Fibrlok II 2529 Universal Optical Fiber Splice is a high performance,
More informationBeam Loss Position Monitoring with Optical Fibres at DELTA
Beam Loss Position Monitoring with Optical Fibres at DELTA Frank Rüdiger M. Körfer (DESY) W. Göttmann (HMI Berlin) G. Schmidt (DELTA) K. Wille (DELTA) 24. June 2008 Frank Rüdiger 1 Table of Content 1.
More informationAQ7275 OTDR Optical Time Domain Reflectometer
AQ7275 OTDR Optical Time Domain Reflectometer Wide range of models available Supporting FTTH to core networks Short dead zone (0.8 m) High dynamic range (45 db) Dead zone Bulletin AQ7275-02E Meets a broad
More information