Features. Drop-in type detector
|
|
- Jeffry Watkins
- 5 years ago
- Views:
Transcription
1 SUSPNDD SOIDS NYZR Model SSF-6 The SSF-6 is an analyzer used to conduct continuous optical measurements of the concentration of solids. It can measure the concentration of suspended solids (SS) in sewage, night soil, and industrial waste treatment plants, as well as the concentration of mixed liquor suspended solids (MSS) in aeration tanks. The SSF-6 consists of a small lightweight infrared detector, which is designed to be immersed in sample solutions, and a transmitter for converting the measured SS concentration to 4 - md analog output signals and RS-485 digital signals. Features xtensive measurement ranges The SSF-6 can conduct measurements across wide concentration ranges, such as ranges of - mg/ (ppm) and - mg/ (ppm). You can choose a - range type or a -range type. There are selectable modes for switching, manual ranging, auto ranging and remote ranging for each model. Infrared detector The light source of the SSF-6 is an infrared lightemitting diode (D). This D is long lasting and is almost completely unaffected by colored samples. In addition, the pulsed light signals processing prevents it from being affected by sunlight and other forms of ambient light. Practical calculation features The SSF-6 comes with useful features for calculation functions. The unit employs piecewise linear approximation to correct values that were analyzed manually. It also performs -point calibration to correct approximate calculations. nd self-diagnosis including system error, calibration error and others is available. Detector options: Throw-in type and drop-in type Detectors are classified by installation conditions into Drop-in type detector different types: throw-in type and drop-in type, the latter in which the detector is inserted into a long protection pipe that is - 6 meters long. Stain-resistant design The small and lightweight detector is made of stainless steel and has a stain-resistant design. The detector plane is washed by the flow of sample water, which helps to prevent dirt deposits from accumulating. Jet cleaner (option for the drop-in type) water (air) jet cleaner or pulse air jet cleaner can be purchased as an option to remove thick layers of dirt deposits that form on the detector plane, such as when the flow rate of sample water is too slow. Digital signal RS-485 equipped as standard. Supports Modbus communication. onfiguration <Field site> <Instrument room> Detector Dedicated cable 5m or m Transmission output 4 - m D Digital communication output RS-485 Receiver (DS) Range switching signal, upper/lower limit alarm, instrument failure alarm (contact) - 4V
2 Standard Specifications Model : SSF-6 Measurement method : Infrared scattered light measurement Items measured : SS concentration in water and MSS concentration in activated sludge ntire measurement range : - mg/ Measurement : The following ranges are available. ranges -range; - / - /5-5/ - / - / -range; - /5/ - 5// - // ( selectable range switching; manual, automatic, and remote.) Measurement unit Display : mg/ or ppm : D display with backlight Minimum value displayed; (the first digit is fixed at zero.) Power supply : - 4V ±%, 5/6Hz Power consumption : pprox. V Transmission output ontact output : D 4 - m (isolated) oad resistance; 6Ω or less : Six items available between under maintenance, instrument failure, range display *, concentration upper alarm, concentration lower alarm, output for cleaner, under cleaning, and power interrupt.(for details about connecting when the resistance load is VD. and the load is V, see Note 4 in "Terminal onnections".) alibration ecause the composition and properties of suspended solids (mixed liquor suspended solids) are extremely complex, it is impossible to clearly define specific substances as standard suspended solids (mixed liquor suspended solids). Thus, calibration using manual analysis data at each site is required. ) alibration using manual analysis (weight method) as standard onduct manual analysises (weight method) and record SSF-6 readings for as many samples as possible. Plot the regression line on the scatter diagram by comparing the manual analysis values to the SSF- 6 readings. Using this regression line, calibrate the instrument. )Using the standard scatter plate to perform calibration fter calibration using manual analysises (weight method), measure the supplied scatter plate and record the indicated values. Then calibration using the scatter plate will be available. ontact input Repeatability Stability Response time *: If automatic or remote is selected as the range switching mode for the -range type, contact points are used exclusively to display the range. : Remote range switching, cleaning command : ±% FS (with standard solution) : Zero drift; ±% FS/7 days (with zero water) Span drift; ±% FS/7 days (with standard solution) :5 minutes or less for 9% response when set at position 4. (9 selectable settings between s and 8min) mbient conditions : º, 95%RH or less (no condensation) Sample conditions : Temperature; - 5º (no freezing). Flow rate;.5 -.5m/s (.5 -.m/s for float type) Protective construction : ; IP65 Detector : Underwater; Withstanding pressure. construction MPa Detector cable length : 5 m (standard) ight source : Infrared D 945nm Photo sensor : Silicon photodiode able entry : able gland (6 pcs) for ø6 - cable onduit thread G/ (when cable glands are removed) Mounting :; Mounted on a 5 pipe or wall/rack Detector; Throw-in type or drop-in type with protection pipe Material : ; D (aluminum die-cast) olor; Metallic silver Detector; SUS6 *, glass K7 Weight : ; pprox..kg Detector; pprox. kg (including 5 m cable) *: ontact us for details about how to prevent possible corrosion caused by samples or ambient condition at site. Detector installation conditions void installing the detector in a location where the sample flow rate is slow or stagnant. If a thick layer of dirt deposits forms on the detector plane of the drop-in type, we recommend that you purchase the optional water (air) jet cleaner or pulse air jet cleaner to remove the deposits. Note that samples containing dissimilar metals (particularly iron) can cause crevice corrosion. If corrosion occurs after installation, we recommend covering the unit with anti-corrosion zinc tape (code No. 48).
3 Terminal onnections -range type -range type Dedicated cable White lack 4 Power source output Dedicated cable White lack 4 Power output Orange White Shield Detector output Orange White Shield Detector output Detector Range switching command input * Spare leaning start command input * Non-voltage contact ON-resistance 5Ω Short circuit current (max.) md Open circuit voltage 4VD Detector Range switching command input * Range switching command input * leaning start command input * Non-voltage contact ON-resistance 5Ω Short circuit current (max.) md Open circuit voltage 4VD Default settings NO N Unassigned Instrument failure alarm output * Range indication output Under maintenance output oncentration lower limit alarm output *4 oncentration upper limit alarm output *4 leaner solenoid valve output ontact capacity VD. (resistance load) Default settings NO Instrument failure alarm output * N Unassigned Range indication output Range indication output oncentration lower limit alarm output *4 oncentration upper limit alarm output *4 leaner solenoid valve output *5 ontact capacity VD. (resistance load) 7 7 Transmission output 4 - md 7 7 Transmission output 4 - md RS485 output RS485 output N N - 4V 5/6Hz (instrument power) power output (for cleaner) N N - 4V 5/6Hz (instrument power) power output (for cleaner) *: Range when closed. *: Pulse width ms or longer. *: an be changed to "Power interrupt". *4: V, possible when protection element is connected. *: Range and when closed. *: Pulse width ms or longer. *: an be changed to "Power interrupt". *4: V, possible when protection element is connected. *5: an be changed to "Under maintenance". Display indication Key lock indicator SS correction indicator rror type indicator Measurement item indicator Upper/lower limit indicator Model indicator ower display Time indicator Mode indicator Unit indicator Measured value indicator <Display in measurement mode>
4 Dimensions Unit : mm Mounted on wall or rack 5 Mounted on a 5 pipe 8 8 (7) Display Operation panel 8 Sun shade Saddle Display Operation panel 8 8 Throw-in type detector Drop-in type detector (no protection pipe) Dedicated cable able support Wire Protection cover 5 Sun shade 5 pipe Ground terminal 6 ± ø55 Main body 5 9 (5) (5) able entry able entry 4ø () Stay Ground terminal (4) (8) 5 ø8 able support Wire Dedicated cable Main body Photo sensor (short range) ø48 ø5 ight source D Photo sensor (long range) Photo sensor (short range) ø48 ø5 ight source D Photo sensor (long range) Window Window
5 Drop-in type Protection pipe length: Dedicated cable Drop-in type Protection pipe length: m or less m or more Dedicated cable Rubber stopper ø8 Rubber stopper ø8 ± 5 ø / Protection pipe (5) SUS4 or SUS6 -part split type Joint flange ± 5 Protection pipe (5) SUS4 or SUS6 Drop-in type detector Drop-in type detector 5 ø6.5 5 ø6.5 Installation example Drop-in type 7 or greater ce Power cable Wire: VV.5 - Finishing OD: ø6 - lass D ground Transmission output cable Wire: VVS.5 - Finishing OD: ø6 - ontact signal cable Wire: VV.5 - Finishing OD: ø6 - For RS485 digital transmission PV-S cable Finishing OD: ø6-4± 5 able entry (6 pcs) (onduit thread G/ when cable glands are removed) 8 Mounting bracket ± Pole stand (5) + Protection pipe 8 Drop-in type detector Installation conditions We recommend mounting a sun shade (option) when installing the unit in a location exposed to direct sun light. (~)
6 Drop-in type with pulse air jet cleaner 4± 5 7 or greater 5 or greater Maintenance clearance Maintenance clearance 6 Sun shade (optional) Operation panel *4 5 or greater Maintenance clearance lass D ground Supplied by user * Power cable Wire: VV.5 - Finishing OD: ø6 - Transmission output cable Wire: VV.5 - Finishing OD: ø6 - ontact signal cable Wire: VV.5 - Finishing OD: ø6 - For RS485 digital transmission PV-S cable Finishing OD: ø6-85±5.5 + Protection pipe Drop-in type detector ±5.5 From ( - ) Mounting bracket ± 8 ± 8 able entry ( pcs) able gland for ø6 - cable leaning air introduction tube Stop valve * Stop valve leaner with filter * ir supplied by general plant air compressor * *: Not required when cleaning air is supplied by a built-in pump. djust a pressure between. and.mpa (normally.mpa) when supplying air. *: Install stop valves to protect the pressure gauge. lose the valves after adjusting the pressure. *: Use a filter to remove dust and oil. *4: If the water (air) jet cleaner is used, a solenoid valve will be installed. Installation conditions: ) Maintain a distance of no more than 5m between the operation panel and detector. ) Make sure to allow for sufficient length of the cleaning air introduction tube to draw up the protection pipe easily and perform maintenance. ut make it as short as possible. Make sure to install the cleaning air introduction tube so that it does not become folded. ) Make sure to allow for sufficient clearance in front of the operation panel and on each side. 4) We recommend mounting a sun shade (option) when installing the unit in a location exposed to direct sun light. Float type X MX9 Detector cable ±5.5 5 pipe Pole stand 555 Pulley Pulley Wire alancer 5~ Float Detector ø6 Guide roller nti-loosening clamp racket Guide pipe racket pprox. 54~ pprox.68 ± ±5 H4 H Guide pipe length mm mm 7 Maintenance clearance Float installation depth H pprox. - mm pprox. - 7mm pprox. - mm pprox. - 7mm Wire Guide roller Height during maintenance H4 pprox. 4mm pprox. 55mm pprox. 4mm pprox. 55mm VIW X (9)
7 Product code Throw-in type / Drop-in type SSF6-- D F G H Y ustom spec. code; Numeric digit: 9 lphabet: Z Y 5 6 Y Measurement range ( selectable range switching: manual, automatic, and remote) - / - /5-5/ - / - / - /5/ - 5// - // Other specifications* Measurement units mg/ (standard) ppm Measurement items -range -range General SS (calibration solution: fly ash) MSS (calibration solution: fly ash and kaolin) mounting 5 pipe mounting (standard) Wall or rack mounting Surface finish (coating) * Standard coating High performance coating rrester (power line/transmission line) * None Included able entries for power, transmission and signal cable *4 able glands for ø6 - cable (standard able glands (G/ conduit threads when the cable glands are detached) NPT / supplied with adapters hood(sun shade) None (standard) quipped (5 pipe mount) (ode No. 7499K) quipped (wall mount) (ode No. 6945) Detector mounting Throw-in type Drop-in type, protection pipe not required Protection pipe length N (no protection pipe) ombined equipment None Float type detector (m guide pipe: self-cleaning, used for surface measurements) mounting unit Float type detector (m guide pipe: self-cleaning, used for surface measurements) mounting unit Dedicated cable length 5m (standard) m Other specifications (max. m) Marking Japanese (standard) nglish *. Specify a value in the range of -. *. Standard coating: Melamine primer and topcoat. verage film thickness: Greater than µm. Glossiness: G4. High performance coating: poxy primer and middle coat, polyurethane resin topcoat. verage film thickness: Greater than µm. Glossiness: G8. *. (simplified) ceramic surge arrester is mounted on the power line and transmission line. *4. There are 6 cable entries with cable glands for a ø6 - cable (G / conduit threads when the cable glands are detached). The NPT / comes with SUS6 adapters. fter detaching the cable glands, insert the required number of adapters into the cable entries and screw them into place. When cable entries ports are not used, make sure to leave the standard cable glands in place. These glands function as a seal. *5. For more information detailed specifications of combined equipment, please contact one of our sales representatives. Notes. This model is the successor to the SSF-. (Maximum measurement range expanded from -. djustablevoltage power supply. RS-485 equipped as standard.). The optional protection pipe mounting brackets for the drop-in type ZH- (for both vertical and diagonal installation) or ZSS- (flexible type) can be ordered separately as needed. The optional pole stand Z- can be ordered separately as needed.. The optional calibration kit for SS concentration analysis can be ordered separately as needed.
8 Drop-in type with protection pipe SSF6-- D F G H Y ustom spec. code; Numeric digit: 9 lphabet: Z D D F G H I J K 4 Y Measurement range ( selectable range switching: manual, automatic, and remote) - / - /5-5/ - / - / - /5/ - 5// - // Other specifications* Measurement units mg/ (standard) ppm Measurement items -range -range General SS (calibration solution: fly ash) MSS (calibration solution: fly ash and kaolin) mounting 5 pipe mounting (standard) Wall or rack mounting Surface finish (coating) * Standard coating High performance coating rrester (power line/transmission line) * None Included able entries for power, transmission and signal cable *4 able glands for ø6 - cable (standard) able glands (G/ conduit threads when the cable glands are detached) NPT / supplied with adapters hood(sun shade) None (standard) quipped (5 pipe mount) (ode No. 7499K) quipped (wall mount) (ode No. 6945) Detector mounting Drop-in type, protection pipe SUS4 included Drop-in type, protection pipe SUS6 included Protection pipe length N (no protection pipe).m.5m.m.m (-part split).5m.5m (-part split) 4.m 4.m (-part split) 4.5m (-part split) 5.m (-part split) 6.m (-part split) ombined equipment None Water jet cleaner ir jet cleaner Pulse air jet cleaner (externally supplied air: Type ) Pulse air jet cleaner (built-in air pump: Type ) Dedicated cable length 5m (standard) m Other specifications (max. m) Marking Japanese (standard) nglish
9 ccessories Pole stand 5 pole stanchion used to mount the transmitter and detector. 6± 6 6± 6 4-ø5 Rubber cap Z-- Z 9 Pole stand length.m.6m (standard) ustom spec. Materials and finish 5 steel pipe (SGP) and steel plate, Metallic silver coating 5 SUS4, no coating 5 SUS4, metallic silver coating ustom spec. Pipe 5(ø6.5) ± Note. general pole stanchion used to mount the on-site transmitter/detector. Note. The pole stanchion has a flat plate base with reinforcement ribs to support the pole. 5 t6 Mounting brackets ZSS-- Z Material SUS4 7 (standard) ustom spec. Note. The stainless steel and aluminum casting brackets used to fasten the 5 protection pipe for the drop-in type ph/orp/do/ SS analyzer detector (SUS) to the 5 pole stanchion. The brackets are mounted in sets of. The mounting position can be easily adjusted, enabling the protection pipe to be fastened vertically or diagonally. Note. ombined detectors: H-N95, JH-95, H-G95, PH-95D, O-95, JO-95, PO-95D or SSD-6/SSD-6/SSF- 6. (4) Direction rm 5 Direction (ø6.5) Direction Direction Protection pipe rm mounting reference diagram
10 International Operations: DKK-TO orporation 9-, -home, Takadanobaba, Shinjuku-ku, Tokyo Japan Tel : Fax : Information and specifications are for a typical system and are subject to change without nofice. Issued on 5//
OIL FILM DETECTOR (Long-distance correspondence Version)
OIL FILM DETECTOR (Long-distance correspondence Version) ODL-6A The Model ODL-6A monitors a water surface for the presence of an oil film floating on the surface. The instrument projects a laser beam onto
More informationSPECIFICATION SHEET ORGANIC POLLUTION MONITOR. Model: OPM-410A - Organic Pollution Monitor - Issue: OPM-410A-0107-R0 Page 1 ISO ISO-9001
ISO-14001 ISO-9001 SPECIFICATION SHEET ORGANIC POLLUTION MONITOR Model: OPM-410A The Model OPM-410A monitors organic pollution in water from industrial effluent, rivers etc.. The design and construction
More informationStandard Specifications
Organic Pollution Monitor (UV Meter) OPM-6 The OPM-6 is one of our latest models, and represents the culmination of more than three decades of product development and field experience. This model is an
More informationOIL FILM DETECTOR (Flame-proof Version) SODL-1600
OIL FILM DETECTOR (Flame-proof Version) SODL-600 The model SODL-600 is a flame-proof type oil film detector. This model monitors a water surface for the presence of an oil film floating on the surface.
More informationStandard Specifications
Organic Pollution Monitor (UV Meter) OPM-6 The OPM-6 is one of our latest models, and represents the culmination of more than three decades of product development and field experience. This model is an
More informationGeneral Specifications
eneral Specifications DO70 Optical Dissolved Oxygen Sensor EERA DO70 optical dissolved oxygen sensor is designed for using in water treatment plants such as sewage treatment works and effluent activated
More informationOPTISENS TUR 2000 Technical Datasheet
OPTISENS TUR 2000 Technical Datasheet Sensor for turbidity measurement in water and wastewater Rugged design for harsh applications Integrated transmitter with direct 4...20 ma output Near infrared light
More informationSPECIFICATION SHEET. SLC-1615 (for low concentration) SLC-1625 (for high concentration) SILICA ANALYZER
ISO-14001 ISO-9001 SPECIFICATION SHEET SILICA ANALYZER Model: SLC-1605 (for very low concentration) SLC-1615 (for low concentration) SLC-1625 (for high concentration) This equipment is used for high accuracy
More informationGeneral Specifications
General Specifications Model DM8 Vibration Type Liquid Density Meter Overview In 1967, YOKOGAWA developed the Model VD6 Vibration Type Liquid Density Meter in response to user requests for an online density
More informationRefrigerated Air Dryer
Refrigerated ir ryer E/F Series For use in Europe, sia and Oceania Standard/ E Series H HW Power supply voltage: Single-phase 230 V (50Hz) 3E 4E 6E 8E 11E 15E1 22E 37E 55E 75E ir flow capacity (m3/h [NR])
More informationINDEX. Air flow capacity SCFM (m 3 /h [ANR]) Model Outlet air pressure dew point Note) 37 F (2.8 C) 45 F (7.2 C) 50 F (10 C)
Refrigerated ir ryer Series IF For use in North, entral & South merica Protect Pneumatic quipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor,
More informationRefrigerated Air Dryer
Refrigerated ir ryer Series For use in North, entral & South merica Protect Pneumatic quipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor, and
More informationSIMRAD GD10PE IR GAS DETECTOR
SIMRAD GD10PE IR GAS DETECTOR Operating Manual P3404E 1st edition Jan. 2004 www.simrad-optronics.com CONTENTS 1. PRODUCT DESCRIPTION... 5 1.1 General description... 5 1.2 Construction... 5 1.3 Application
More informationGas leak detection + trapped person alarm
GB 555H40 Ed.0 AKO-5554 AKO-5584 AKO-5554 AKO-5584 Gas leak detection + trapped person alarm User manual 555H40 Ed.0 Index Page Versions and references...3 Equipment description...4 Warnings...5 Maintenance...5
More informationGeneral Specifications
General Specifications Model OX400 Low Concentration Zirconia Oxygen Analyzer The OX400 is a highly accurate and reliable low-concentration zirconia oxygen analyzer that is capable of measuring a wide
More informationModel Q45P/R. ph/orp Monitor...
Model Q45P/R ph/orp Monitor... Sensor Mounting Configurations The Differential Difference ORP Monitor ATI's versatile Q45P/R ph/orp system is designed for use in all industrial and municipal applications.
More informationClass 1 laser beam sensor safe for your eyes
113 Sensor SERIES Related Information General terms and conditions... F-7 About laser beam... P.199~ Sensor selection guide... P.1~ General precautions... P.11 PHOTO PHOTO PARTICUR MEASURE ITY panasonic.net/id/pidsx/global
More informationIN-SITU ZIRCONIA OXYGEN ANALYZER
IN-SITU IRCONIA OXYGEN ANALYER DATA SHEET FK8, KM, TA This oxygen analyzer is used to continuously measure oxygen concentration in combustible exhaust gas of industrial boilers or furnaces, and is ideally
More informationOptical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator
TECHNICAL GUIDE Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator The XPlorer Range XPlorer is a new range of analogue addressable detectors and interfaces developed for all who
More informationClass 1 laser beam sensor safe for your eyes
13 Sensor SERIES Related Information General terms and conditions... F-17 About laser beam... P.13~ Sensor selection guide... P.967~ General precautions... P.1 PHOTO PHOTO Conforming to EMC Directive Conforming
More informationModel Q45P/R. ph/orp Monitor...
Model Q45P/R ph/orp Monitor... Sensor Mounting Configurations The Differential Difference ORP Monitor ATI's versatile Q45P/R ph/orp system is designed for use in all industrial and municipal applications.
More informationA New Standard of Excellence
A New Standard of Excellence PREVENTION IS SO EASY... LIVING THROUGH A DISASTER IS NOT The reliable identification of low combustion oxygen in a fired heater or boiler has always been critical to the effectiveness
More informationDESIGN MANUAL. The information in this doucment is applicable to sensors built in September, 2009 or later (Firmware 3.0)
DESIGN MANUAL MODEL GIR910 INFRARED CARBON DIOXIDE (CO 2 ) GAS SENSOR 70091 The information in this doucment is applicable to sensors built in September, 2009 or later (Firmware 3.0) The information and
More informationOLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.
FIXED GAS DETECTION OLCT 700 Series OLCT 700/710 industrial gas detection sensors are a new generation of intelligent sensor modules that incorporate and integrate several leading edge improvements. &
More informationIN-SITU ZIRCONIA OXYGEN ANALYZER
IN-SITU IRCONIA OXYGEN ANALYER DATA SHEET FK8, KM, TA This oxygen analyzer is used to continuously measure oxygen concentration in combustible exhaust gas of industrial boilers or furnaces, and is ideally
More informationIN-SITU ZIRCONIA OXYGEN ANALYZER <HART communication>
DATA SHEET IN-SITU ZIRCONIA OXYGEN ANALYZER ZFK8, ZKM-2, ZTA This oxygen analyzer is used to continuously measure oxygen concentration in combustion exhaust gas of industrial boilers
More informationClass 1 laser beam sensor safe for your eyes
1129 PHOTO PHOTO PARTICUR Sensor SERIES Related Information General terms and conditions... F-3 About laser beam... P.193~ guide... P.121~ General precautions... P.19 Conforming to FDA regulations (-11
More informationHygro/hygrothermal transducers (hygrometric)
Data Sheet 90.7031 Page 1/7 Hygro/hygrothermal transducers (hygrometric) for measuring relative humidity and temperature for mounting indoors, outdoors, and in air ducts with resistance, current or voltage
More information1. Quick start-up guide
1. Quick start-up guide This quick guide leads the way to install, start-up and configure necessary parameters in the normal cases. 1. PREPARING INSTALLATION Install fiber optic cable inside conduit. This
More informationROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A
SPECIFICATIONS (Revised 1/12/2006) ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A The system shall operate on the principle of light absorption. It shall consist
More informationInductive Conductivity
Inductive Conductivity THORNTON Leading Pure Water Analytics 7100E Non-Fouling Sensors PEEK or PFA Wetted Parts Excellent Chemical Resistance 0/4 to 20mA Outputs for Conductivity & Tempreature 4 Relays
More informationRefrigerated Air Dryers
Refrigerated ir Dryers Series F/U Standard/High Temperature ir Inlet Type Protect Pneumatic Equipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor,
More informationRPS/DPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control. Features:
GE Measurement & Control RPS/DPS 8100 High Accuracy Resonant Pressure Sensor For over 35 years, Druck has manufactured precision pressure sensors with a capability to meet critical applications in industrial,
More informationMultiFix Central unit
MultiFix Manual MultiFix Central unit 2015-12- 01 C85C5EN16 Contents CONTENTS... 2 GENERAL INFORMATION... 4 SAFETY INFORMATION... 4 DESCRIPTION OF OPERATION... 4 FUNCTIONS FOR MEASUREMENT... 4 UNPACKING...
More informationHygro/hygrothermal transducers (hygrometric)
Data Sheet 907031 Page 1/7 Hygro/hygrothermal transducers (hygrometric) for measuring relative humidity and temperature for mounting indoors, outdoors, and in air ducts with resistance, current or voltage
More informationGeneral Specifications
General Specifications GS J0H-0E Model MVHK Digital Limit Alarm (DC Type) with Active Color PV Display General This plug-in type Digital Limit Alarm for DC input receives DC current or DC voltage signal.
More informationDräger Polytron 5700 IR Detection of flammable gases and vapours
Dräger Polytron 5700 IR Detection of flammable gases and vapours The Dräger Polytron 5700 IR is a cost effective explosion-proof transmitter for the detection of flammable gases in the lower explosive
More informationCR A-F-A-E-HQQE 3x400/ HZ
GRUNDFOS DATA BOOKLET CR32--2 A-F-A-E-HQQE 3x/69 5 HZ Grundfos pump 9612212 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/crfam/9612212/cr-32--2-a-f-a-e-hqqe.html
More informationModel D12-IR. Digital Gas Transmitter...
Model D12-IR Digital Gas Transmitter... ATI s Series D12 gas transmitter line now includes a versatile Infrared system that can be configured for LEL or select toxic gases. The D12-IR utilizes a compact
More informationEMS510 PS-1 COMPLIANT OPACITY/DUST MONITOR
EMS510 PS-1 COMPLIANT OPACITY/DUST MONITOR The EMS510 provides continuous, low maintenance, precision measurement of Opacity and Dust (mg/m3). It is designed for monitoring visible smoke in the exhaust
More informationAquaLynx 200 ADX. Monitoring and Control System. Background. Operation
AquaLynx 200 ADX Monitoring and Control System The RODI Systems AquaLynx 200 ADX is a unique monitoring system for water treatment applications. The AquaLynx 200 ADX offers a dependable yet affordable
More informationAnalog Transmitter AT1000 AT1
Technical Information Analog Transmitter AT1000 AT1 Alarm Transmitter for Mechanical Level Gauges Application AT1 analog transmitter is designed to be installed to the LT, and LTC series float level gauge.
More informationSpecifications. Table of contents. 2:Specification. 3:Composition. 4:Instruments outside figure
DUST DENSITY METER (DDM-2001) Specifications Table of contents 1:Outline 2:Specification 3:Composition 4:Instruments outside figure 1) Main body control box 2) Detector 3) Optical fiber cable 4) Purge
More informationSIMRAD GD10 IR GAS DETECTOR
1 SIMRAD GD10 IR GAS DETECTOR Operating Manual 5th Edition P3359E October 1999 1 CONTENTS Section Page 1. PRODUCT DESCRIPTION 3 1.1 General description 3 1.2 Construction 3 1.3 Application areas 4 1.4
More informationDräger Polytron 5720 IR Toxic Gas Detection
Dräger Polytron 5720 IR Toxic Gas Detection The Dräger Polytron 5720 IR is a cost-effective explosion proof transmitter for the detection of carbon dioxide in volume percentage or ppm It uses a high-performance
More informationUltrasonic Point Level Switches
see more at SORInc.com Request Quote Ultrasonic Point Level Switches Ultrasonic point level switches are a cost-effective solution for your applications. Installation requires mounting the sensor (threaded
More informationProduct Overview. Ordering Information DM-LK-D10 DM-LK-D10-C. Dust & Opacity Meter Complete Set Controller Unit. Sender Receiver SDS-V5 SDR-V4 HPB-82S
D10 is a type-approved measuring device which combines the advantages of the measuring principles transmittance and scattered light forward. Therefore, it is ideal for measurement of very low to high dust
More informationVentostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:
Ventostat Wall Mount Telaire Wall Mount, Humidity and Temperature Transmitters Features: Patented, Absorption Infrared Gas sensing engine provides high accuracy in a compact low cost package. Patented
More informationAir Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)
http://www.pisco.co.jp AIR PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Filter for Removing Dust and Drain in Compressed Air Air Filter 220 Filter for Drain and Dust (Filtering Accuracy: 5µm) Resin-made
More informationTHEORY OR OPERATION 2 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 OPTIONS 11
Table of Contents INTRODUCTION 1 THEORY OR OPERATION 2 DESCRIPTION 5 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 SPECIFICATIONS 10 OPTIONS
More informationCMT MANUAL 6. NMC SENSORS
CMT MANUAL 6. NMC SENSORS TABLE OF CONTENTS INDEMNITY... 5 DOCUMENT INFORMATION... 5 ACKNOWLEDGEMENTS... 5 6.1 INTRODUCTION... 6 6.2 TEMPERATURE AND HUMIDITY SENSORS... 7 6.2.1. TEMPERATURE SENSOR... 7
More informationZircomat Oxygen Analyzers
Zircomat Oxygen Analyzers Finally Hassle Free Stack Gas Oxygen Measurement Many of the top fortune 500 companies have already discovered that installing a ZIRCOMAT Oxygen analyzer is the smart way to measure
More informationRPS/DPS High Accuracy Resonant Pressure Sensor. GE Oil & Gas. Features:
GE Oil & Gas RPS/DPS 8000 High Accuracy Resonant Pressure Sensor Since 1972, Druck has manufactured precision pressure sensors with a capability to meet critical applications in industrial, aerospace,
More informationUser's Manual. Model VJQ8 Pulse to Analog Converter. (Multi-function) MODEL AND SUFFIX CODES CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT
User's Manual Model VJQ8 Pulse to Analog Converter (Multi-function) (Isolated Single-output and Isolated Dualoutput Types) Thank you for purchasing the JUXTA Signal Conditioner. Please read through this
More informationMultiFix Central unit
MultiFix Manual MultiFix Central unit 2015-09- 10 C85B5EN16 Contents CONTENTS... 2 GENERAL INFORMATION... 4 SAFETY INFORMATION... 4 DESCRIPTION OF OPERATION... 4 FUNCTIONS FOR MEASUREMENT... 4 UNPACKING...
More informationHEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR
HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR 2 MB 103 TRANSFORMER TEMPERATURE CONTROL UNIT WITH CONTROL SIGNAL Recent approval of new
More informationUltrasonic Switches. Features & Benefits
Why use an ultrasonic switch over other level technologies? Depending upon your application, there may be three or four technologies equally suited for your application; however; only one will be the best
More informationDetectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.
Détecteur de gaz OLCT80 Detectors-Transmitters for Flammable, Toxic Gases and Oxygen Non-intrusive operation via intrinsically safe infrared remote control Disponible en version déportée, ADF ou de SI
More informationDräger Polytron 8700 IR Detection of flammable gases and vapors
Dräger Polytron 8700 IR Detection of flammable gases and vapors The Dräger Polytron 8700 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit
More informationMXD75 Multi Channel Suspended Solids and Turbidity Transmitter
~ Specialists in process suspended solids & turbidity ~ MXD75 Multi Channel Suspended Solids and Turbidity Transmitter Up to 3 Sensors on one Transmitter. Parameters include Suspended Solids, Turbidity
More informationLaser Scan Micrometer Page 418. Laser Scan Micrometer Page 423
Laser Scan Micrometers Laser Scan Micrometer Page 418 Laser Scan Micrometer Measuring Unit and Display Unit Package Page 419 Laser Scan Micrometer Measuring Unit Page 420 Laser Scan Micrometer Page 423
More informationDräger Polytron 5720 IR Detection of carbon dioxide
Dräger Polytron 5720 IR Detection of carbon dioxide The Dräger Polytron 5720 IR is a cost effective explosion proof transmitter for the detection of carbon dioxide in percent volume or ppm It uses a high
More informationFilter for Drain and Dust (Filtering Accuracy: 5µm) Optional Selection of Direct Mount Pressure Gauge (Compact size).
http://www.pisco.co.jp AIR PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Redcing Valve with Built-in Filter Filter Regulator 238 Filter for Drain and Dust (Filtering Accuracy: 5µm) Plastic made Bowl
More informationMODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power
Digital Panel Meters 47 Series THERMOCOUPLE INPUT DIGITAL PANEL METER (4-digit, LED display type) Functions & Features 4-digit thermocouple input digital panel meter 1/8 DIN size Moving average function
More informationHydrazine Analyzer Series 2171 Specifications
Hydrazine Analyzer Series 2171 Specifications 70-82-03-64 November 2009 Introduction The 2171 is the most advanced hydrazine instrument specifically developed for use in continuous measurement and determination
More informationIMR 5000 Operating Manual S/N: SAMPLE For information only! IMR Environmental Equipment Inc.
IMR 5000 Operating Manual S/N: For information only! IMR Environmental Equipment Inc. INTRODUCTION 3 SAFETY INSTRUCTIONS 3 SYSTEM DESCRIPTION - IMR 5000 GAS ANALYSIS SYSTEM 4 Function chart IMR 5000 -
More informationAir Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)
http://www.pisco.co.jp AIR PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Filter for Removing Dust and Drain in Compressed Air Air Filter 220 Filter for Drain and Dust (Filtering Accuracy: 5µm) Resin-made
More informationMicro/Ultra Filtration System StamoClean CAT 430
Technical Information TI 338C/07/en/10.03 No. 51508729 Micro/Ultra Filtration System StamoClean CAT 430 Long-term Stable Membrane Filter for Immersion Operation in Activated Sludge Basins or Wastewater
More informationABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements
Specifications COMMANDER 150 Universal Process Indicator High visibility 6-digit LED display the clearest view of your process status 0.1% measurement accuracy precise indication of process measurement
More informationMiniature Infrared Temperature Sensors with Optional Touch Screen Display. PSC-SSS-PM with touch screen display (-CRT version)
PSC-SSS-PM Series Miniature Infrared Temperature Sensors with Optional Touch Screen Display PSC-SSS-PM with touch screen display (- version) FEATURES Miniature sensing head and configurable electronics
More informationSAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)
PART 1 - GENERAL A. RELATED DOCUMENTS SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu) Federal, State, and local requirements as applicable. Attached Permit Attached drawings B. SUMMARY 1. Provide
More informationVentostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.
GE Sensing & Inspection Technologies Ventostat Wall Mount Telaire Wall Mount, Humidity and Temperature Transmitters Features: Patented, Absorption Infrared Gas sensing engine provides high accuracy in
More informationVentostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.
GE Sensing & Inspection Technologies Ventostat Wall Mount Telaire Wall Mount, Humidity and Temperature Transmitters Features: Patented, Absorption Infrared Gas sensing engine provides high accuracy in
More informationBeck. The differential pressure transmitter for air
Beck. The differential pressure transmitter for air Differential pressure transmitter 984 General description The differential pressure transmitters of the 984 series are used to measure differential pressure,
More informationINSTRUMENTATION AND CONTROL DEVICES FOR HVAC
PART 1 GENERAL 1.01 RELATED REQUIREMENTS SECTION 23 0913 INSTRUMENTATION AND CONTROL DEVICES FOR HVAC A. Section 26 2717 - Equipment Wiring: Electrical characteristics and wiring connections. 1.02 ADMINISTRATIVE
More informationWH EN IGH T T C LO SED
AR EA kajdfkjl; lkjdflkjal; ldkfj;alk alskjdf ;lsdkf 7079 ph/orp Transmitter 70-82-03-08 1/97 Page 1 of 5 Specification Overview The 7079 ph/orp Transmitter is designed for chemical process industry applications
More informationZirconia Oxygen Gas Analyzers
Fuji Instrumentation & Control Fuji Electric s Direct Insertion Type Zirconia Oxygen Gas Analyzers ZIRCOMAT-P ZIRCOMAT-C Detctor No sampling device is required Compact and light
More informationNGC-UIT2-ORD-R Remote User Interface Terminal for Raychem NGC Systems Installation Instructions
NG-UIT2-ORD-R Remote User Interface Terminal for Raychem NG Systems Installation Instructions Description The NG-UIT2-ORD-R is a wall-mounted display which allows the User Interface Terminal (UIT) to be
More informationSPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES
SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES USER INSTRUCTIONS FOR THE CHEMGARD INFRARED GAS MONITOR SERIES To completely customize the specification to your exact application, modification to the
More informationIRtech. E instruments. IRtech Radiamatic IR20 LS series. Infrared Technology
E instruments IRtech Temperature range up to 2200 C Optical resolution up to 300:1 Close focus 0,5mm 8-14µm, 1.6µm, 1µm, 2.3µm, 3.9µm, 4.2µm, 4.6µm, 5.1µm and 7.9µm Spectral response Dual laser true target
More informationCR20-07 A-F-A-E-HQQE 3x400/ HZ
GRUNDFOS DATA BOOKLET CR2-7 A-F-A-E-HQQE 3x4/69 5 HZ Grundfos pump 965513 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/crfam/965513/cr-2-7-a-f-a-e-hqqe.html
More informationDräger Polytron 8720 IR Detection of carbon dioxide
Dräger Polytron 8720 IR Detection of carbon dioxide The Dräger Polytron 8720 IR is an advanced explosion proof transmitter for the detection of carbon dioxide in percent volume or ppm It uses a high performance
More informationULTIMA X5000. MSAX5000.com
ULTIMA X5000 MSAX5000.com WE KNOW YOU RE TIRED OF... NEEDING TO DISCONNECT POWER BEFORE CHANGING A SENSOR REMEMBERING HOW TO CALIBRATE THIS THING HAVING TO PULL SO MUCH WIRE AT EVERY GAS DETECTOR INSTALLATION...
More informationFS-100 Series OUTLINE MAIN APPLICATIONS FEATURES LEVEL SWITCH
PERFECT ISOLATION BY MAGNET COUPLING COVERING HIGH TEMP., HIGH PRESS., AND VACUUM APPLICATIONS PRESSURE TIGHT FLAMEPROOF FOR HYDROGEN ATMOSPHERE READY SPRING BALANCED DISPLACER TYPE FS- Series LEVEL SWITCH
More informationDESIGN MANUAL MODEL GIR900 INFRARED COMBUSTIBLE GAS SENSOR
DESIGN MANUAL MODEL GIR900 INFRARED COMBUSTIBLE GAS SENSOR 70086 The information in this doucment is applicable to sensors built in September, 2008 or later (Firmware 3.0) The information and technical
More informationMinimal maintenance requirements - No consumables and low cost of ownership. Rapid, accurate results - for safe operation of coal handling systems
Product Data Sheet CODEL Continuous Mill Fire Detection Coal Mill CO Analyser Low cost, low maintenance devices for continuous monitoring. Robust infrared gas analyser - accurate and reliable operation
More informationBuzzer Unit. TAN-5000 Series. Operating Manual
PT1E-1040 Buzzer Unit TAN-5000 Series Operating Manual Request for the Customers Read and understand this operating manual before using the buzzer unit. Use the buzzer unit in accordance with the operating
More informationNo.THD51E To prevent accidents arising from the use of this product, please ensure the operator using it receives this manual.
Instruction manual Hygrothermo transmitter THD-500 Series No.THD51E1 2001.11 To prevent accidents arising from the use of this product, please ensure the operator using it receives this manual. Notes This
More informationSIMRAD GD10P - IR GAS DETECTOR OPERATING MANUAL
SIMRAD GD10P - IR GAS DETECTOR OPERATING MANUAL P3359E 8th edition - November 2005 Simrad Optronics ASA Kabelgaten 4B P.O. Box 174, Økern NO-0509 OSLO, NORWAY Phone +47 22 66 60 00 Fax +47 22 66 60 01
More informationSTT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009
STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009 Introduction Honeywell s STT 3000 family of microprocessor based transmitters covers the full
More information818 Series. Low-Power Detectors ABSOLUTE SPECTRAL RESPONSIVITY (A/W)
132 P hotonics LASER DIODE TESTING FIBER OPTIC TEST Key Features Power levels from pw to 2W Wavelengths from 190 1800 nm Proprietary detector optics Patented, matched OD3 attenuator NIST/NPL-traceable
More informationDrain Separator for Vacuum
Separator for Vacuum Series M emoves water droplets from air by simply installing in vacuum lines. Prevents damage of vacuum pumps and ejectors. Ejector Z Z Z M MV EP elated separator for vacuum side port
More information1. GENERAL INTRODUCTION 2. OPERATING CONDITIONS
1. GENERAL INTRODUCTION OM IE1 series three phase asynchronous motor with cast iron housing. These IE1 motors are for application of petroleum, chemical, metallurgical, cement and paper industries, especially
More informationDräger Polytron 8700 IR Detection of flammable gases and vapors
Dräger Polytron 8700 IR Detection of flammable gases and vapors The Dräger Polytron 8700 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit
More informationAnalog Room Pressure Monitor RPC Series
Description The Room Pressure Monitor is used to measure differential pressure in the range of 0.125 to 1"wc or 30 to 250 Pa. It combines precision high sensitivity silicon sensing capabilities and the
More informationAdvance Optima Module Magnos 17
Advance Optima Module Magnos 17 Service Manual 43/24-1002-0 EN Table of Contents Page Chapter 1: Description of functions 1-1 Chapter 2: Module variants and components 2-1 Chapter 3: Analyzer variants
More information120D, 150D, 190D, 240D, 370B. How to Order 220V 240V 400V 440V. Note 1) Select one applicable voltage. Voltage. Voltage. Symbol. Model 370B 220V 240V
Refrigerant R7 0, 0 90 I ir compressor Refrigerant 0kW kw 90kW kw Refrigerant R 70 I Refrigerant R7, R Series I Large 0,, 90,, 70 0 90 R7 Size 70 7 9 0 90 Three Voltage 7 9 Voltage 00/00 to 0V (/Hz) 0V
More informationSieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required
Sieger Sensepoint The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a high quality, low cost solution to their industrial gas monitoring needs. Sieger Sensepoint Fit For Purpose
More informationDust Concentration Meter
Dust Concentration Meter To Sense Breaks or Tears in Filter Bags, to Improve Product Quality, and to Eliminate related Environmental and Safety Risks Triboelectric Dust Monitor Particles in the air are
More informationPOINT HELIDECK LIGHTS PRL-LSM LED v4 LOW SURFACE MOUNT LIGHT
Compliances: ETL Listed to UL 1598A Marine Vessels at -40 deg C to +55 deg C, IP66 & IP67 ETL Listed to CSA C22.2 No. 137-M1981 & No. 250.0-08 Canada ETL Listed to UL 1598 at -40 deg C to +55 deg C IMO
More information