NO (SPST-NO) 10 A Internal installations Particularly suited for wall mounting

Size: px
Start display at page:

Download "NO (SPST-NO) 10 A Internal installations Particularly suited for wall mounting"

Transcription

1 Features PIR oveent detector for internal or external installations - wall ounting Sall size Adjustable abient light Adjustable ight On Tie Universal ounting position - perits the selection of any area for survey Series - PIR oveent detector 10 A Internal installations Particularly suited for wall ounting External installations Particularly suited for wall ounting uber of contacts Rated current/maxiu peak current A Rated voltage/maxiu switching voltage V AC 5 (120/230 V) oinal lap rating:incandescent (120/230 V) W copensated fluorescent (120/230 V) W uncopensated fluorescent (120/230 V) W halogen (120/230 V) W Standard contact aterial oinal voltage Rated power AC/ (50 Hz)/W Abient light lx ight on tie after last detection Depth of field 230/ /230 2,300 2, / 2.5/ 10 s...12 in 10 s...12 in IP 40 IP 54 1

2 Features PIR oveent detector for internal installations Ceiling ounting Sall size Adjustable abient light Adjustable ight On Tie Series - PIR oveent detector 10 A Surface ounting Output connected to supply voltage Recessed ounting Output connected to supply voltage uber of contacts Rated current/maxiu peak current A Rated voltage/maxiu switching voltage V AC 5 (120/230 V) oinal lap rating:incandescent (120/230 V) W copensated fluorescent (120/230 V) W uncopensated fluorescent (120/230 V) W halogen (120/230 V) W Standard contact aterial oinal voltage Rated power AC/ (50 Hz)/W Abient light lx ight on tie after last detection Sensing area diaeter 230/ /230 2,300 2, /1 2/1 10 s...12 in 10 s...12 in 8 8 IP 40 IP 40 2

3 18 Series - PIR oveent detector 10 A Features PIR oveent detector for internal installations, with potential free contact Applications where interface to PC or BMS is required Ceiling ounting Sall size Adjustable abient light Adjustable ight On Tie Surface ounting Output with potential free contact Recessed ounting Output with potential free contact uber of contacts Rated current/maxiu peak current A Rated voltage/maxiu switching voltage V AC 5 (230 V) oinal lap rating: incandescent (230 V) W copensated fluorescent (230 V) W uncopensated fluorescent (230 V) W halogen (230 V) W Standard contact aterial oinal voltage / Rated power AC/ (50 Hz)/W / Abient light lx ight on tie after last detection Sensing area diaeter 250/ /400 2,500 2, ,000 1, ,000 1, V 2/1 2/ s...12 in 10 s...12 in 8 8 IP 40 IP 40 3

4 18 Series - PIR oveent detector 10 A Ordering inforation Exaple: 18 series, PIR oveent detector for internal installations, wall ounting, 1 O (SPST-O) 10 A contact, V AC supply Series Type 0 = Internal installation - wall ounting 1 = External installations 2 = Internal ceiling installation - surface ounting 3 = Internal ceiling installation - recessed ounting Insulation Dielectric strength between open contacts V AC 1,000 Between supply and contact V AC 1,500 (types , ) Other data Screw torque 0.5 Max. cable size Wiring diagra Type / Type / Contact circuit 0 = Voltage output 3 = Volt-free output contact (18.21/ only) Supply voltage 024 = 24 V AC/ for types 18.21/ only 230 = V Supply version 8 = AC (50/60 Hz) o. of poles 1 = Single pole switching 1 O (SPST-O), 10 A Following the initial power-on, and power-on following a power interruption, the detector akes a hardware-software initialisation for approxiately 30 seconds. However, the behavior of the output during this 30 seconds will depend on certain circustances: - If the detector was in the On state before the power interruption, and if the lighting level is (currently) below the pre-set, then the output contact will iediately close when the power is re-applied, for the tie delay set by the potentioeter (irrespective of whether oveent is being detected). - If the detector was in the Off state before the power interruption, or if the abient light is currently over the pre-set, then the detector will not switch-on until the end of the initialisation phase (assuing oveent is then detected) = abient light 2= light on tie 1= abient light 2= light on tie Type / The output relay will reain On for the pre-set tie, following the last detection of oveent. ux level Set 2 1 1= abient light 2= light on tie Detection of oveent Contact 4

5 Mounting and orientation 18 Series - PIR oveent detector 10 A Wall ounting Surface ounting Recessed ounting Sensing area 18.01, Wall ounting Ceiling ounting Ceiling ounting ( ) Internal installations External installations Side view Plan view 18.21, Internal ceiling installation, surface ounting or recessed ounting Single installation Multiple installation Accessories Bea liiter for and PIR oveent detectors Reduces the area of survey to 2 eters diaeter (versus 8) at an installation height of 2.8 eters. 5

NO (SPST-NO) 10 A Internal installations Particularly suited for wall mounting

NO (SPST-NO) 10 A Internal installations Particularly suited for wall mounting Features PIR movement detector for internal or external installations - wall mounting Small size Adjustable ambient light intervention threshold Adjustable Light On Time Universal mounting position - permits

More information

PIR movement and presence detectors 10 A

PIR movement and presence detectors 10 A PIR movement and presence detectors 10 A Hotel room energy-enabling units ighting control in corridors (for hotels, offices and hospitals) Offices, swimming baths and schools SЕRIES Staircase light control

More information

Eagle PIR-018 / PIR-045 / PIR-100 Outdoor Passive Infrared Detectors

Eagle PIR-018 / PIR-045 / PIR-100 Outdoor Passive Infrared Detectors Eagle PIR-018 / PIR-045 / PIR-100 Outdoor Passive Infrared Detectors Description The Eagle Series of PIR-018, PIR-045 and PIR-100 Outdoor Passive Infrared Detectors are designed for detection of intruders

More information

Movement and presence detectors 10 A. 18 Series. Type Type Type Since 1954, light when you need it

Movement and presence detectors 10 A. 18 Series. Type Type Type Since 1954, light when you need it Since 1954, light when you need it 18 Series Movement and presence detectors 10 A Type 18.41 Ceiling mounted movement detector. Specifically for corridors up to 30 meters in length Type 18.51 Ceiling mounted

More information

DUAL TECHNOLOGY OCCUPANCY/VACANCY SENSOR SWITCH (WS XX DT XX/WS OS DTDR XX)

DUAL TECHNOLOGY OCCUPANCY/VACANCY SENSOR SWITCH (WS XX DT XX/WS OS DTDR XX) OVERVIEW The Dual Technology Occupancy/Vacancy Sensor Switch applies Lutron s exclusive XCT Technology to the ultrasonic as well as the passive infrared technology in this sensor to create a product that

More information

GE Lighting. Lighting Controls. DALI Digital Lighting Controls

GE Lighting. Lighting Controls. DALI Digital Lighting Controls GE ighting ighting Controls I Digital ighting Controls the I Protocol Multi-functional control of I-ready GE uminaires 1-1 to I converters available for analogue luminaires I CB Type 2 - complete programmable

More information

M.A.M.I. Silentron. Outdoor Wireless Dual Technology Intrusion Detector

M.A.M.I. Silentron. Outdoor Wireless Dual Technology Intrusion Detector 55 Dual Tech long range outdoor detector 55 Dual Tech wide angle outdoor detector Outdoor Wireless Dual Technology Intrusion Detector Silentron the 55 55 55 55 M.A.M.I. anufacturing and inor inventions

More information

Motion Sensor. For Outdoor Use. Wall & ceiling mounted. Quick & Easy Installation 2 Channels

Motion Sensor. For Outdoor Use. Wall & ceiling mounted. Quick & Easy Installation 2 Channels MS3602CH 2 Channel Motion Sensor For Outdoor Use Wall & Ceiling Mounted Quick & Easy Installation 2 Channels Channel 2 Distance Wiring Diagram 220-240V ~ 50Hz 14A Max. (cosø=1) 3000W for incandescent load

More information

Heating, air-conditioning, cooling

Heating, air-conditioning, cooling Series description Design landless circulation pup with threaded connection, blockingcurrent proof EC otor and integrated electronic power control. Application All hot water heating systes, air-conditioning

More information

S15 SERIES. Ceramics. Beverage & Bottling

S15 SERIES. Ceramics. Beverage & Bottling PHOTOELECTRIC Tubular sensors S15 SERIES The new S15 series of M18 tubular sensors offers both plastic case version S15-PA and stainless steel IP69K housing version S15-NA. S15-PA plastic version is recoended

More information

PRODUCT INFORMATION FWE200DH EXTRACTIVE SCATTERED LIGHT DUST MEASURING DEVICE RELIABLE DUST MEASUREMENT IN WET GASES. Dust measuring devices

PRODUCT INFORMATION FWE200DH EXTRACTIVE SCATTERED LIGHT DUST MEASURING DEVICE RELIABLE DUST MEASUREMENT IN WET GASES. Dust measuring devices PRODUCT INFORMATION FWE200DH EXTRACTIVE SCATTERED LIGHT DUST MEASURING DEVICE RELIABLE DUST MEASUREMENT IN WET GASES Dust easuring devices RELIABLE DUST MEASUREMENT IN WET GASES Particle easureent in a

More information

Abella Digital Fade Dimmer

Abella Digital Fade Dimmer LUTRON ABELLA DIGITAL FADE DIMMER Abella Digital Fade Dimmer press on to favorite level; press off press twice for full on press, hold and release for gradual fade-to-off touch buttons to adjust light

More information

FR-A180 FR-A360. Occupancy detector. Use

FR-A180 FR-A360. Occupancy detector. Use 5 488 Occupancy detector with daylight sensor Occupancy detector with integral daylight sensor for demand-based control of HVAC systems and lighting. Adjustable switch-on and switch-off delay Adjustable

More information

REPRINT ZKG PROCESS PROCESS

REPRINT ZKG PROCESS PROCESS 4 Planning detail for integration of the into the existing plant peripherals a rotary feeder, the otor for 180 t/h of raw eal, for exaple, has a rating of 5.5 and during operation it uses less than 1.

More information

Eco-sensors - PIR. Catalogue number(s): / / Use. 1. Use Technical characteristics (continued)

Eco-sensors - PIR. Catalogue number(s): / / Use. 1. Use Technical characteristics (continued) Page. Use..................................... 2. Technical characteristics................. 3. Dimensions.............................2 4. Connection.............................2 5. Removal................................3

More information

3. Intended use. 4. Function. 1. Product characteristics. 2. Safety. Functional description. Channel A light. Motion detector

3. Intended use. 4. Function. 1. Product characteristics. 2. Safety. Functional description. Channel A light. Motion detector EN Motion detector themova S360-101 DE WH 1030565 themova S360-101 DE GR 1030566 themova S360-101 AP WH 1030555 themova S360-101 AP GR 1030556 1. Product characteristics 307067 Passive infra-red motion

More information

II SL. Installation Guide. VOLTEX IMS64-2 Dual output indoor flush mount PIR motion detector IMS64-2

II SL. Installation Guide. VOLTEX IMS64-2 Dual output indoor flush mount PIR motion detector IMS64-2 II112918-SL Installation Guide VOLTEX IMS64-2 Dual output indoor flush mount PIR motion detector IMS64-2 TECHNICAL DATA Rated voltage: 220V-240V~ 50/60Hz Load: Load 1( /T1) for Lighting Incandescent: Max.

More information

SECTION LIGHTING CONTROLS

SECTION LIGHTING CONTROLS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 09 23 LIGHTING CONTROLS SPEC WRITER NOTE: 1. Delete between //----// if not applicable to project. Also, delete any other item or paragraph not applicable to

More information

1. Product characteristics 4 2. Safety 5 3. Proper use 5 4. Operation 6

1. Product characteristics 4 2. Safety 5 3. Proper use 5 4. Operation 6 307214 1103107701 EN Presence detector theronda S360-101 DE WH 2080565 theronda S360-101 DE GR 2080566 theronda S360-101 AP WH 2080555 theronda S360-101 AP GR 2080556 1. Product characteristics 4 2. Safety

More information

Technical Description

Technical Description Overview are differentiated depending on applied edia. Light, one of the edia, is also utilized for a which is called a photoelectric. It is a non-contact type which is applicable to sensing presence,

More information

The Power To Supply... All Your Electrical Products

The Power To Supply... All Your Electrical Products ENERGY EFFICIENT RETROFIT SOLUTIONS The Power To Supply... All Your Electrical Products www.cef.co.uk All products are subject to availability and are correct at the time of print. Errors and omissions

More information

Technical Description

Technical Description Overview are differentiated depending on applied edia. Light, one of the edia, is also utilized for a which is called a photoelectric. It is a non-contact type which is applicable to sensing presence,

More information

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded) T M 1 isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded) Technical Bulletin NAE1012372 / 03.2015 isopv

More information

11,1 30. Ordering data

11,1 30. Ordering data ID Compact control module with ambient light sensor and motion sensor Compact dimensions for luminaire installation For up to 10 DSI or I ballasts I/DSI output channels with adjustable negative offset

More information

Excel-EN Conventional Fire Control Panel

Excel-EN Conventional Fire Control Panel Available as 2, 4, 6, 8,10 or 12 zones Approved to EN54-2 & 4 Modular expansion zone cards Programmable relays and outputs Optional additional sounder circuits Optional additional programmable outputs

More information

Tri-level Control HF Sensor

Tri-level Control HF Sensor Photocell Advance RX TM Synchronisation control oop in oop out Tri-level Control HF Sensor Synchronised Control Version with Photocell Advance TM Applications Occupancy detector with tri-level control

More information

Light & Motion. Sample applications 259. Ceiling sensors. Wall sensors. Outdoor sensors. Motion. Light &

Light & Motion. Sample applications 259. Ceiling sensors. Wall sensors. Outdoor sensors. Motion. Light & «Our intelligent sensing allows an increase in physical and emotional well-being of people in the room. and brightness are detected reliably: For individual, comfortable and increased energy-saving. Sample

More information

PräsenzLight PräsenzLight PräsenzLight A.. PräsenzLight A..

PräsenzLight PräsenzLight PräsenzLight A.. PräsenzLight A.. Presence detector PräsenzLight 180.. PräsenzLight 360.. PräsenzLight 180-100A.. PräsenzLight 360-100A.. D F GB E I NL S N FIN DK Bedienungsanleitung 2 Notice d utilisation 26 Installation manual 50 Manual

More information

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems X X testregistrierung Type Web server, also for mobile devices Zone modules Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems X-AIRCONTROL zone

More information

3. Proper use. 4. Function. 1. Product characteristics. 2. Safety. Function description. Channel A light. Motion detector

3. Proper use. 4. Function. 1. Product characteristics. 2. Safety. Function description. Channel A light. Motion detector 307021 3. Proper use EN Motion detector themova P360-100 UP WH 1030600 themova P360-100 UP GR 1030601 The motion detector is intended for interior. The motion detector is eclusively intended for the use

More information

Maxim3 TM Series IP66. LED Vapor Tight - Waterproof Key Features

Maxim3 TM Series IP66. LED Vapor Tight - Waterproof Key Features Maxim3 TM Series PROJECT NAME: CATALOG: NOTES: LED Vapor Tight - Waterproof Key Features Up to 146 IP66 87 UL 4, 5 & 8 K & K 110-277V NSF Stainless Steel Clips Operating Temp - o F to 105 o F 7 Year Warranty

More information

Comfort. COMFORT Sabiana circular unit heaters, for ceiling installation only,

Comfort. COMFORT Sabiana circular unit heaters, for ceiling installation only, Cofort Circular Unit Heater COMFORT Sabiana circular unit heaters, for ceiling installation only, are especially suitable for high roos, even if the optiu ratio between the air flow-rate and the heat output

More information

Movement-based energy control

Movement-based energy control 04 Movement-based energy control 94 International catalogue 2015 4.1 Microwave-based movement sensors 4.2 PIR-based movement sensors 4.2.1 Ceiling-mount 4.2.2 Wall-mount 4.3 Twilight switches 4.4 LED lights

More information

ENGINEERING STANDARD FOR FIRE-FIGHTING SPRINKLER SYSTEMS ORIGINAL EDITION. Nov. 1993

ENGINEERING STANDARD FOR FIRE-FIGHTING SPRINKLER SYSTEMS ORIGINAL EDITION. Nov. 1993 ENGINEERING STANDARD FOR FIRE-FIGHTING SPRINKLER SYSTEMS ORIGINAL EDITION Nov. 1993 This standard specification is reviewed and updated by the relevant technical coittee on Jan. 2000. The approved odifications

More information

VITMR-EBDSPIR-PRM. PIR Presence/Absence Detector IR with Ceiling Rose. Product Guide. Overview. Features

VITMR-EBDSPIR-PRM. PIR Presence/Absence Detector IR with Ceiling Rose. Product Guide. Overview. Features Product Guide VITMR-EBDSPIR-PRM PIR Presence/Absence Detector IR with Ceiling Rose Overview The VITMR-EBDSPIR-PRM PIR (passive infrared) presence detector provides automatic control of lighting loads.

More information

APPLICATION DATA SHEET

APPLICATION DATA SHEET APPLICATION DATA SHEET Control Systems Transmitters Sensors Accessories Wall, 19 Rack or Panel Mounting Units 110/230V 50/60Hz AC operation 250 Addressable devices as: Relays, 4-20 Inputs or Gas Detectors

More information

, ,

, , 796-2028, 796-2021, 796-2025 Batten mount PIR detectors Overview This series of miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional manual control

More information

PresenceLight 180 PresenceLight 360

PresenceLight 180 PresenceLight 360 Presence detector PresenceLight 180 PresenceLight 360 Art. Nr. 200 0 050 Art. Nr. 200 0 000 D F GB E I NL Bedienungsanleitung 2 Notice d utilisation 22 Installation manual 42 Manual de instrucciones 62

More information

Save energy. ARGUS presence detectors

Save energy. ARGUS presence detectors Save energy Ef cient energy use 2 Keeping energy costs down Increasing energy costs and growing awareness of the environment in modern buildings management now mean that more innovative solutions for efficient

More information

NEW. lighting management - stand alone detectors, power packs. Passage detection - Infrared technology. Detectors with power packs

NEW. lighting management - stand alone detectors, power packs. Passage detection - Infrared technology. Detectors with power packs lighting management - stand alone detectors, power packs 488 03 488 20 488 07 488 06 Pack Cat.Nos Traffic detection - Infrared technology Ceiling mounting detector Set via a thumbwheel 1 488 03 360 - detection

More information

Technical Description

Technical Description overview Sensors are differentiated depending on applied edia. Light, one of the edia, is also utilized for a which is called a photoelectric. It is a non-contact type which is applicable to sensing presence,

More information

End To End Optical Beam Smoke Detector. Additional Information

End To End Optical Beam Smoke Detector. Additional Information End To End Optical Beam Smoke Detector Additional Information EN 1. Multiple Zone Wiring When using more than one System Controller on a single zone of a conventional Fire Control Panel (FCP), it is important

More information

IN THE MATTER of the Resource Management Act AND applications for resource consent under Part 6

IN THE MATTER of the Resource Management Act AND applications for resource consent under Part 6 BEFORE THE PORIRUA CITY COUNCIL AND GREATER WELLINGTON REGIONAL COUNCIL IN THE MATTER of the Resource Manageent Act 1991 AND applications for resource consent under Part 6 BETWEEN WELLINGTON REGIONAL COUNCIL

More information

Product Specifications Warning Light Control Cabinet

Product Specifications Warning Light Control Cabinet NOVA Energy & Automation Product Specifications Warning Light Control Cabinet Model NEAS-RB024D-EWA 03 January 2012 Product Description 1. Standard Applications The Nova NEAS-RB024D-EWA is an integrated

More information

ATSTORM v2. The sensor with FCES technology is connected to the interface with a communication cable.

ATSTORM v2. The sensor with FCES technology is connected to the interface with a communication cable. ATSTORM v2 ATSTORM v2 is a storm detector that measures the environmental electric field. It is fully automatic, without mobile parts, robust and highly reliable The storm detector ATSTORM v2 basic configuration

More information

2000W PIR LIGHT CONTROLLER SLB2000-Black SLW2000-White INSTALLATION & OPERATING INSTRUCTIONS

2000W PIR LIGHT CONTROLLER SLB2000-Black SLW2000-White INSTALLATION & OPERATING INSTRUCTIONS 2000W PIR LIGHT CONTROLLER SLB2000-Black SLW2000-White INSTALLATION & OPERATING INSTRUCTIONS SLB2000 PIR LIGHT CONTROLLER - BLACK WEATHERPROOF IP44 PIR SWITCHING 2000w MAXIMUM MANUAL ON/OFF OVERRIDE TIME

More information

Labkotec Ice Detector

Labkotec Ice Detector Labkotec Ice Detector LID 3300IP Level and flow know-how since 1964 Benefits of using Ice Detector Stops wind turbine to prevent icethrow Safety first of all! Safety device Authorities / construction licence

More information

EBDSPIR-PRM-VFC & EBDSPIR-PRM-VFC-NC

EBDSPIR-PRM-VFC & EBDSPIR-PRM-VFC-NC Product Guide EBDSPIR-PRM-VFC & EBDSPIR-PRM-VFC-NC Ceiling PIR presence/absence detector Overview The EBDSPIR-PRM-VFC PIR (passive infrared) presence detector provides automatic control of lighting loads

More information

CHAPTER 4 EXPERIMENTAL STUDIES

CHAPTER 4 EXPERIMENTAL STUDIES 113 CHAPTER 4 EXPERIMENTAL STUDIES 41 INTRODUCTION Based on the results of the theoretical studies on the air-cooled GAX based vapour absorption refrigeration syste that were carried out, the design and

More information

DHL-LP-LED Low Profile LED Linear High/Low Bay

DHL-LP-LED Low Profile LED Linear High/Low Bay Job Information Type: Catalog #: Project: Comments: Prepared by: WARRANTY WARRANTY YEAR TEN INCLUDES LABOR ALLOWANCE 2 65W/90W Version 23.81 2 135W Version For 4 dimensions see pg 2 23.81 23.81 23.81 12.6

More information

A. This Section includes the following lighting control devices:

A. This Section includes the following lighting control devices: Attachment G LIGHTING CONTROL SPECIFICATIONS (Download Document separately) LIGHTING CONTROL SPECIFICATIONS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including

More information

Wide Band Flame Detector KLC 20 for all kind of oil flames with intermittent burnerr operations

Wide Band Flame Detector KLC 20 for all kind of oil flames with intermittent burnerr operations KLC 20 0 (formerly known as KLC 2002) CE0085BP0001 Technical Information Wide Band Flame Detector KLC 20 for all kind of oil flames with intermittent burnerr operations Short Description The wide band

More information

Warning. Specifications, designs and other content appearing in this brochure are current as of May 2013 but subject to change without notice.

Warning. Specifications, designs and other content appearing in this brochure are current as of May 2013 but subject to change without notice. arning sk a qualified installer or contractor to install this product. Do not try to install the product yourself. Iproper installation can result in water or refrigerant leakage, electrical shock, fire

More information

False Ceiling HF Sensors

False Ceiling HF Sensors False Ceiling HF Sensors HC009S/EXT HC018V/EXT HC019V/EXT Applications Ideally suited to retrofit projects where the luminaire is too small to accomodate the sensor internally, this motion sensor can be

More information

Full power for the home and garden.

Full power for the home and garden. Pups and watering systes Full power for the hoe and garden. Pups and watering systes because every drop counts. Watering pups Sustainable top quality. Fro the high-pressure pup to the preiu sprayer Kärcher

More information

Motion detector themova P360 KNX UP WH themova P360 KNX UP GR

Motion detector themova P360 KNX UP WH themova P360 KNX UP GR 307079 EN Motion detector themova P360 KNX UP WH 1039600 themova P360 KNX UP GR 1039601 1. Product characteristics 4 2. Safety 5 3. Proper use 6 4. Function 6 5. Detection area 10 6. Installation 13 7.

More information

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features Product Guide PIR/INT & PIR/INT-D Batten mount PIR detectors Overview The PIR/INT & PIR/INT-D miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional

More information

Networked Access Control Panel. Installation Guide

Networked Access Control Panel. Installation Guide XP2M Networked Access Control Panel V1.0X Installation Guide X P 2 M A C C E S S C O N T R O L S Y S T E M Installation Guide Document Ref: PLAN XP2M Installation Guide V4(G)2010 Access Control Services

More information

Ceiling PIR HS presence detector. Product Guide. Overview. Features

Ceiling PIR HS presence detector. Product Guide. Overview. Features Product Guide 796-2047 Ceiling PIR HS presence detector Overview The 796-2047 (passive infrared) presence detector provides automatic control of lighting loads with optional manual control. This is a high

More information

SENTINEL A - Fault Passage Indicator

SENTINEL A - Fault Passage Indicator SENTINEL A - Fault Passage Indicator AMPEREMETRIC FAULT PASSAGE INDICATORS FOR OVERHEAD MV NETWORKS Installed on poles of overhead lines, the Overhead-Sentinel-A range allows locating the fault arisen

More information

1. Basic safety information 3 2. Proper use 3

1. Basic safety information 3 2. Proper use 3 307146 03 EN Presence detector thepiccola P360-100 DE WH 2090200 1. Basic safety information 3 2. Proper use 3 Disposal 3 3. Device description 4 4. Installation and connection 4 Installing the presence

More information

1. Basic safety information 3 2. Proper use 3

1. Basic safety information 3 2. Proper use 3 310481 01 EN Motion detectors theluxa P220 WH 1010605 theluxa P220 BK 1010606 theluxa P300 WH 1010610 theluxa P300 BK 1010611 1. Basic safety information 3 2. Proper use 3 Disposal 3 3. Description 4 4.

More information

Product Specifications Warning Light Control Cabinet

Product Specifications Warning Light Control Cabinet NOVA Energy & Automation Product Specifications Warning Light Control Cabinet Model NEAS-RB024A-IWA 03 January 2012 Product Description 1. Standard Applications The Nova NEAS-RB024A-IWA is an integrated

More information

Tri-level Control Sensor

Tri-level Control Sensor Daylight Monitoring Photocell Advance TM One-Key Commissioning Ambient daylight threshold oop in oop out Tri-level Control Sensor HC038V HCD038 Detached inear Version with Remote Control Applications Occupancy

More information

Dust Alert 75. *shown with optional external keypad and display

Dust Alert 75. *shown with optional external keypad and display Dust Alert 75 Designed to differentiate between gross failure and dust leakage from faulty/failing filter systems including bag filters Automatic internal zero and reference self-checks for regulatory

More information

Intelligent Temperature Management. ThermaCool - Say goodbye to inefficient temperature peaks. GeoClima Inclusive Technical Package

Intelligent Temperature Management. ThermaCool - Say goodbye to inefficient temperature peaks. GeoClima Inclusive Technical Package Intelligent Temperature Management ThermaCool - Say goodbye to inefficient temperature peaks GeoClima Inclusive Technical Package ThermaCool incorporating Phase Change Material Phase Change Material Technology

More information

ECO-IR 360C NT. Presence detector. Art. Nr Bedienungsanleitung 2. Notice d utilisation 22. Installation manual 42

ECO-IR 360C NT. Presence detector. Art. Nr Bedienungsanleitung 2. Notice d utilisation 22. Installation manual 42 Presence detector ECO-IR 360C NT Art. Nr. 202 0 400 D F GB E I NL S N FIN DK Bedienungsanleitung 2 Notice d utilisation 22 Installation manual 42 Manual de instrucciones 62 Istruzioni per l uso 82 Gebruikershandleiding

More information

BUILDING MANAGEMENT SYSTEMS. Introduction to Building Management Systems

BUILDING MANAGEMENT SYSTEMS. Introduction to Building Management Systems BUILDING MANAGEMENT SYSTEMS Introduction to Building Management Systems The Building Management System is used for all the functions carried out by the building including energy services security monitoring,

More information

Integrated SensorDIM LED Driver Daylight Monitoring Version

Integrated SensorDIM LED Driver Daylight Monitoring Version TM Integrated SensorDIM ED Driver Daylight Monitoring Version Model: HEC730 with HRC-0.1 ED + ED - ED current selection 0 9 Daylight threshold Antenna module connector Buzzer ] PUSH Extended antenna 99

More information

Emergi-Lite Orbis detectors

Emergi-Lite Orbis detectors Emergi-Lite Orbis detectors Emergi-Lite Orbis brings the latest in fire detector microprocessor technology to the Firetec and Eurofire systems. Non-addressable (conventional) smoke and heat sensors respond

More information

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded) T M 1 isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded) Technical Bulletin NAE1012670 / 08.2013 isopv425

More information

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features Product Guide EBMPIR-MB Batten mount PIR detectors Overview The EBMPIR-MB series of miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional manual

More information

SA100L. General Description. Features. Temperature Limit Controller SA100L. Simple Mounting on DIN Rail. Over/Under Temperature Protection

SA100L. General Description. Features. Temperature Limit Controller SA100L. Simple Mounting on DIN Rail. Over/Under Temperature Protection SA00 SA00 SA00 SA00 Temperature Limit ontroller SA00L FM APPROVED SA00L General Description The SA00L is a FM approved high limit or low limit controllers. The SA00 is a socket mounting type temperature

More information

3. Proper use. 4. Function. 1. Product characteristics. 2. Safety. Motion detector

3. Proper use. 4. Function. 1. Product characteristics. 2. Safety. Motion detector EN Motion detector KNX DE WH 1039560 KNX DE GR 1039561 KNX AP WH 1039550 KNX AP GR 1039551 307090 The device is maintenance-free. If the device is opened or penetrated with any object, the guarantee lapses.

More information

North America Version / Dimming Function. Introduction

North America Version / Dimming Function. Introduction orth America Version / Dimming Function /OFF Introduction Automatic switching or dimming when used in combination with 1-10V dimmable ED drivers or ballasts. Built-in daylight. 1-10V interface can match

More information

Integrated PIR detectors

Integrated PIR detectors EBMINT - Product Guide Integrated PIR detectors Overview The EBMINT series of miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional manual control

More information

Passive infrared ceiling sensor

Passive infrared ceiling sensor Passive infrared ceiling sensor 88 Description Control and command device, powered by the SCS BUS, with two different sensors, the combination of which enables managing the light level inside the room,

More information

PPAD-C-230V. Ceiling PIR presence/absence detector. Product Guide. Overview. Features

PPAD-C-230V. Ceiling PIR presence/absence detector. Product Guide. Overview. Features Product Guide PPAD-C-230V Ceiling PIR presence/absence detector Overview The PPAD-C-230V passive infrared presence detector provides automatic control of lighting loads with optional manual control. The

More information

Flame Detector. Model: ZT-30P. User Guide. Document Ref: GLT Zeta Alarms Limited Morfa Road, Swansea, SA1 2EN, United Kingdom

Flame Detector. Model: ZT-30P. User Guide. Document Ref: GLT Zeta Alarms Limited Morfa Road, Swansea, SA1 2EN, United Kingdom Flame Detector Model: ZT-30P User Guide Document Ref: GLT-300-7-1 Zeta Alarms Limited 72 78 Morfa Road, Swansea, SA1 2EN, United Kingdom Phone: +441792 455 175 Fax: +441792 455 176 Website: www.zetaalarmsystems.com

More information

compact office 24V compact office 24V Lux

compact office 24V compact office 24V Lux Presence detector compact office 24V compact office 24V Lux Art. Nr. 201 4 000 Art. Nr. 201 4 001 D F GB E I NL S N FIN DK Bedienungsanleitung 2 Notice d utilisation 21 Installation manual 40 Manual de

More information

Digital Addressable Lighting Interface

Digital Addressable Lighting Interface Digital Addressable Lighting Interface Who started DALI? It is supported by major manufacturers of ballasts Initially promoted by: And now including: BAG, Erco, Insta, Johnson controls, Magnetek, FCS lighting,

More information

Title Page. Report Title: Downhole Power Generation and Wireless Communications. for Intelligent Completions Applications

Title Page. Report Title: Downhole Power Generation and Wireless Communications. for Intelligent Completions Applications Title Page Report Title: Downhole Power Generation and Wireless Communications for Intelligent Completions Applications Type of Report: Quarterly Progress Report Project Report Period: Start Date April

More information

SECTION 26 NX DISTRIBUTED INTELLIGENCE LIGHTING CONTROL SYSTEM HUBBELL CONTROL SOLUTIONS

SECTION 26 NX DISTRIBUTED INTELLIGENCE LIGHTING CONTROL SYSTEM HUBBELL CONTROL SOLUTIONS SECTION 26 NX DISTRIBUTED INTELLIGENCE LIGHTING CONTROL SYSTEM HUBBELL CONTROL SOLUTIONS PART - 1 GENERAL 1 SYSTEM DESCRIPTION A. The distributed lighting control system as specified herein shall be comprised

More information

PRODUCT CATALOGUE LIGHT CONTROL Grässlin products for the intelligent control of light

PRODUCT CATALOGUE LIGHT CONTROL Grässlin products for the intelligent control of light PRODUCT CATAOGUE IGHT CONTRO Grässlin products for the intelligent control of light ight control: Selective use of lighting thanks to intelligent light control Motion and presence detectors Twilight switches

More information

SWITCHLITE MRE SLD MAN SWITCHLITE MRE SLD IP55

SWITCHLITE MRE SLD MAN SWITCHLITE MRE SLD IP55 96239823 SWITCHLITE MRE SLD MAN 96239821 SWITCHLITE MRE SLD IP55 Overview The SWITCHLITE MRE SLD PIR (passive infrared) presence detector provides automatic control of lighting loads with optional manual

More information

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL SECTION 16400 AUTOMATIC TRANSFER SWITCHES 1.01 RELATED DOCUMENTS PART 1 - GENERAL A. Drawings and general provisions of Contract, including General Conditions and Division 1 Specification sections, apply

More information

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref.

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref. Lo-Carbon MULTIVENT MVDC-MS & VENTILATION SYSTEMS Installation and Wiring Instructions Stock Ref. N MVDC-MS 76A 98 0-0V~50Hz PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH THE ILLUSTRATIONS. PLEASE SAVE

More information

SERVICE MANUAL. Commercial Air Conditioning. MULTI upgrade series

SERVICE MANUAL. Commercial Air Conditioning. MULTI upgrade series Coercial Air Conditioning SERVICE MANUAL MULTI upgrade series Models Indoor: AB09CS1ERA AB12CS1ERA AB18CS1ERA AB24ES1ERA AC12CS1ERA AC18CS1ERA AC24CS1ERA AD09LS1ERA AD12LS1ERA AD18LS1ERA AD24LS1ERA Outdoor:

More information

PMCSF6 OCCUPANCY SENSOR

PMCSF6 OCCUPANCY SENSOR PMCSF6 OCCUPANCY SENSOR Lens Main Body Power Cord INTRODUCTION The use of occupancy detectors in commercial and industrial applications can significantly reduce energy usage lessening both energy costs

More information

110 lm w STANDARD SERIES

110 lm w STANDARD SERIES ASD LED Bullet Flood light uses the latest in solid state lighting technology for high efficiency, long life and low maintenance. It s good for facade, landscape and sign lighting applications. Our LED

More information

LaDina. Design by Gigetto Registered Community Design Nr /0002

LaDina. Design by Gigetto Registered Community Design Nr /0002 LaDina Colourful, light and funny LaDina is a new pop archetype. Easy to ove and place it perfectly atches indoor and outdoor settings giving a friendly and war atosphere. Decorative portable lap for outdoor/indoor

More information

ProStar 325 UV-Vis Detector

ProStar 325 UV-Vis Detector Varian, Inc. 2700 Mitchell Drive Walnut Creek, CA 94598-1675/USA Star Chromatography Workstation Version 6 ProStar 325 UV-Vis Detector Control Software Varian, Inc. 2004 Printed in U.S.A. 03-914732-01:Rev.

More information

TABLE OF CONTENTS PAGE. NOTE: Read the entire instruction manual before starting the installation.

TABLE OF CONTENTS PAGE. NOTE: Read the entire instruction manual before starting the installation. nstallation nstructions TABLE OF CONTENTS PAGE SAFETY CONSDERATONS... MODEL NUMBER NOMENCLATURE... 3 PRECAUTONS... 4 NSTALLATON NFORMATON... 5 ACCESSORES... 6 NDOOR UNT NSTALLATON... 7 OUTDOOR UNT NSTALLATON...

More information

Data sheet. Function description. Benefits

Data sheet. Function description. Benefits uminaire-integrated modules ENOTEC modular system 110046819 Control CD I 110046818 Control CD CO1 110046814 ensor ED HF1 110046813 ensor ED HF2 110046816 ensor ED PIR Function description The new ENOTEC

More information

compact office 24V compact office 24V Lux

compact office 24V compact office 24V Lux Presence detector compact office 24V compact office 24V Lux Art. Nr. 201 4 000 Art. Nr. 201 4 001 D F GB E I NL S N FIN DK Bedienungsanleitung 2 Notice d utilisation 22 Installation manual 42 Manual de

More information

1) This manual covers 4400, 5400 and 6400 fire alarm systems. The differences are described in the appropriate sections.

1) This manual covers 4400, 5400 and 6400 fire alarm systems. The differences are described in the appropriate sections. ISSUES ISSUE DATE DETAILS OF CHANGE CHANGED BY 1 16/02/00 ORIGINAL ISSUE - 2 16/01/01 TABLES 2 & 3 UPDATED, ADDED TABLE 4 PWD 3 12/09/01 ADDITIONAL INFORMATION PWD 4 29/11/02 TABLES 2, 3 & 4 UPDATED &

More information

Gira Sensotec / Gira Sensotec LED Motion detector, orientation light and contactless switch in one

Gira Sensotec / Gira Sensotec LED Motion detector, orientation light and contactless switch in one Product information Last updated: 06 / 2015 Gira Sensotec / Gira Sensotec LED Motion detector, orientation light and contactless switch in one Gira Sensotec Gira E2, pure white glossy Gira Sensotec LED

More information

IP 55 (category II) IP 54 (category II) 4. Connection. 1. Basic safety information. 2. Proper use. 5. Installation. 3. Description.

IP 55 (category II) IP 54 (category II) 4. Connection. 1. Basic safety information. 2. Proper use. 5. Installation. 3. Description. EN Motion detectors theluxa P0 WH 0 theluxa P0 BK 0 theluxa P00 WH theluxa P00 BK. Basic safety information WARNING anger of death through electric shock or fire! ¾Installation should only be carried out

More information

Description FEATURES. l Innovative dual mount system requires only one sensor for either flush or surface mount applications

Description FEATURES. l Innovative dual mount system requires only one sensor for either flush or surface mount applications Simple Fit Switching Sensors 1.8m to 3m Cone-shaped detection pattern, 6m radius at mounting height 6.0m AC220~240V/50Hz MK Simple Fit Sensors offer cost effective presence detection for lighting control

More information