LEVEL SWITCH NV-2T v2.1 Installation instructions Order. no: 13169

Size: px
Start display at page:

Download "LEVEL SWITCH NV-2T v2.1 Installation instructions Order. no: 13169"

Transcription

1 LEVEL SWITCH v2.1 Installation instructions Order. no: Description The is intended for dynamic lighting control using dimmable light fittings with control, in order to reduce the lighting time for fluorescent light sources and prolong their life. It is used in combination with one or more presence detectors (e.g. PD2200) in areas such as corridors, stairways and garages. See the application examples in this manual, in the Planning Guide in the Energysaving Detection Technology manual, and at (also see applications for ). Dynamic lighting control means that the output (lighting level) is increased to the normal lighting level (often 80 per cent) when presence is detected in the premises. When presence is no longer detected the lighting is reduced to the base level (usually the lowest possible, generally 1 2 per cent). If someone enters the premises again the lighting is ramped up to the normal level. If the premises remain empty until the timer in has counted down (recommended setting 1 2 hours) the lighting is switched off completely. The reason why the lighting is not switched off as soon as the premises are empty is that frequent switching causes accelerated wear to the fluorescent tubes and shortens their lives. Basic operation When someone enters the premises, the lighting is switched on at the normal level (high level) when presence is detected by the presence detector. When presence is no longer detected, the lights are switched to the base level (low level) and the timer starts counting down the preset time (0 120 minutes). When this time has run out the lighting is switched off completely. When someone enters the premises while the timer is counting down, the lighting is switched from the base level to the normal level, and the timer restarts the countdown when presence is no longer detected. If someone enters the premises when the lighting has been switched off completely, it is immediately switched back on at the normal level. Features Output for control of fluorescent light fittings with adjustable normal level (high level) and base level (low level). Relay output for driving contactor with adjustable timer (0 120 minutes). Input for presence detector or logic module. Blocking input. If a light sensor is connected this can prevent the lighting from being switched on when there is sufficient natural light. input. If one or more pushbuttons are connected (in parallel) the lighting can be switched on/off and ramped up or down manually. SoftDim allows the lighting to be ramped up and down gradually. The rampup rate is adjustable, but the dimming rate is fixed. The Burnin button delivers 100 per cent power for 100 hours Level switch NV2TDSI CNC Extronic AB Stockholm 30m Sweden For digital regulating of luminaires for 230 V regulating0 Current for low level regulating:. Soft 40 ma Dim Breaking capacity v2.1 per block Switch Det. 12 VDC Printed circuit board with LEDs and potentiometers. Auto up to two hours Rest Manual level Red knob 80% level Blue knob1% Completely off Schematic diagram Extronic Elektronik AB 46 (0)

2 for 230 V regulating Current for low level regulating:. 40 ma for 230 V regulating Current for low level regulating:. 40 ma Function, connection and setting Steady glow or flashing when relay is closed, flashes when timer is counting down. Steady glow when lighting set to. Flashing at lower levels. Normal level, adjusted to around 80%. (8 V). Switched on briefly during adjustment. Setting the base level. Switched on briefly during adjustment. Adjustment for day/night transition. Steady glow when light sensor is active. Steady glow when switch is closed. Red LED Red LED Yellow LED Analog control level potentiometer level potentiometer sensor sensivity Green LED D1 D2 C NC Sensitivity block 1 2 CNC Switch 3 4 v2.1 Det. 12 VDC m Soft Dim Relay output Red LED Dimmer Green LED Yellow LED C NC Steady glow when burning in. Burnin start/stop, 100 hours. Controls how long the base lighting stays on before the lighting is switched off. Should be set to 1 2 hours. Controls the rampup rate. Default setting one o clock. Steady glow above 11 V, flashes below 11 V. Steady glow when presence is detected, flashes when auxiliary detector detects presence. sensor Detector Supply voltage VDC level (per cent). 80 light level 3 Base time settings ing level Red knob in level selector 100 % 80 % Detector time, recommended setting 13 minutes. Set at detector (red knob) light level Application example 1 Brief press turns on lighting immediately at maximum level. The light level can be increased or decreased by pressing and holding in a pushbutton. The lighting is dimmed automatically to the minimum level when presence is no longer detected. A. Premises without natural light Premises without natural light, with automatic on/off switching Time The lighting is switched off completely after the set time (12 hours). The lighting is switched on manually at the maximum level by pressing a pushbutton briefly. The lighting is switched off completely by pressing briefly. Blue knob in level selector 2 % level/contactor time, recommended setting two hours. Set at level selector (yellow knob). Base time settings to minimise wear to light sources. B. Corridor with natural light Premises with automatic on/off switching and pushbuttons for manual on/off switching and dimming. A light sensor prevents the lighting from being switched on when there is sufficient natural light. Tid Premises without natural light fittings Premises with natural light fittings sensor Level switch 2 tim. Precens detector Level switch 1 tim. detector Natural light 2 Extronic Elektronik AB 46 (0)

3 Wiring is easily installed on a DIN rack in a standard enclosure. Underneath the label is a cover that can be opened by lifting the bottom edge. Underneath the cover are indicator LEDs for the inputs, outputs and adjustment potentiometers. Terminals 1 2, light sensor The light sensor is connected between terminals 1 and 2. When the blocking function is active, preventing the lighting from being switched on automatically, the green LED glows steadily. If no light sensor is fitted the lighting is always switched on automatically when presence is detected. Terminals 3 4, pushbuttons One or more springloaded momentary pushbuttons can be connected between terminals 3 and 4. A closing pulse switches the lighting on or off. If several pushbuttons are used they are connected in parallel. If a pushbutton is held in, the lighting can be ramped up and down between the onepercent level and the high level. The Switch LED (yellow) glows steadily when a switch is activated. Special configurations for pushbutton: Ramping up to If a 1.5 kω resistor is connected in series, the lighting can be ramped all the way up to 100 per cent, even if the light level potentiometer (red) is set to a lower value. Switching on only If a 4.7 kω resistor is connected in series, the lighting can only be switched on. A single press buys 15 minutes of time without the need for presence to be detected. Switch with fixed positions f a 10 kω resistor is connected in series. a fixedposition switch can be used to switch lighting on and off. 1,5 kω 4,7 kω 10 kω NC input for NC detector If a 22 kω resistor is connected in series with a normally closed (NC) magnetic switch in a door, for example, the lighting can be switched on before presence is detected by the presence detector. The magnetic switch is connected in parallel with the detector. The fixed delay time is two minutes. Extended operation If a 10 kω resistor is connected between terminals 5 and 6 it activates extended operation. See the section on Extended operation for more information. Terminal 7 8, supply voltage VDC supply. 12 VDC LED (green) glows steadily when the voltage is above 11 V. The LED flashes when the voltage is lower. Terminals 9 10, control Signal for controlling fluorescent light fittings. The positive lead () for control from the light fittings must be connected to terminal 9. The negative lead must be connected to terminal 10. If positive and negative are reversed, the lighting will stay on continuously at the lowest possible lighting level. The LED indicates when the potentiometer is controlling the lighting level. The (red) LED glows steadily when the lighting level is at 100 per cent. At lower lighting levels the LED flashes. The lower the lighting level, the shorter the length of time the LED remains on and the longer the time it stays off. The level switch controls the light fittings by lowering the voltage from the fittings. Without a level switch connected the voltage from the fittings control gear is about 1215 V. If the voltage is 0.7 V (when the level switch is unconnected) it could be that one or more light fittings have got the polarities switched. If the power to the is cut the light fittings will turn the lights on at maximum level, provided that the fittings are still supplied with power (230 VAC). Ω 22 k NC Detector Magneticswitch 10 kω Terminals 5 6, detector One or more presence detectors (normally open contacts) are connected so that they shortcircuit terminals 5 and 6 when presence is detected. The yellow Det LED glows steadily when presence is detected, and flashes when an auxiliary detector detects presence. Special configurations for detector input: Detectors that cannot switch lighting on If a 4.7 kω resistor is connected in series, it is possible to connect detectors that are not intended to switch the lighting on, such as an AD350 auxiliary detector. This is connected in parallel with the main detector. This resistor can also be added if the lighting is not to be switched on automatically. Ω 4,7 k Terminals , relay output Relay output CNC. C (14) is the common contact for the internal relay. When the lighting is switched on there is contact between C and. If loses its supply voltage the relay closes and makes contact between C and so that the lighting can remain on. The CNC LED (red) glows steadily when the relay is closed, and flashes when the timer is counting down. When the LED is off the relay is not closed. See wiring example on following page! Extronic Elektronik AB 46 (0)

4 Current for low level regulating:. 40 ma for 230 V regulating Current for 0 low level regulating:. 4 ma Mikrofon AD260 Patent no:s Europe , Sweden , Norway , Finland Voltage: Effect:. load: 230 VAC 50 Hz 9VA/ 5VA 250 V/5 A /relay A 30 VDC Wiring example for PD2200 IR detector Corridor without natural light Premises without natural light fittings Level switch for 230 V regulating 2 tim. Precens detector IR detector PD V 110V C L1 N Level switch NV2TDSI CNC Extronic AB Stockholm Sweden 30m For digital regulating of luminaires for 230 V regulating0 Current for low level regulating:. Soft 40 ma Dim DSI v2.1 block Switch Det. 12 VDC Stabilized power supply supply EXE2000 EXE2000 Extronic AB ï Stockholm ï ï Sweden 15 & 17 = IN 230 V~ Primary 15 17=IN 230 V~ Primary & = = UT OUTPUT ~ 11 & = = UT OUTPUT Current: 0,2 0,2 AA Secondary Secondary Voltage: 13,65V Voltage: 13,65 Current: 1,5 1,5 AA This wiring example can be used in a corridor without natural light, where the lighting is to be switched on automatically when presence is detected. When presence is no longer detected the lighting is dimmed to the base level. If no presence is detected for 1 2 hours the lighting is switched off completely. C NC TP 1 x 4 x 0,25 mm Rectifier EXE2000 Wiring example with AD600 acoustic detector Stairway with natural light fittings Level switch 1 tim. Mikrophone AD260 Acoustic detector AD600 L1 N Acoustic detector AD600 For occupancy detection Extronic AB ï Stockholm ï Sweden sensor Acoustic detector AD600 Relay A C NC C sensor This wiring example with an acoustic detector can be used in closed premises such as a stairway or garage. The lighting is switched on automatically when presence is detected. When presence is no longer detected the lighting is dimmed to the base level, and after 1 2 hours the lighting is switched off completely. A light sensor prevents the lighting from being switched on when there is sufficient natural light. Microphone AD260 12V HF LF LF HF Acoustic detector AD600 For occupancy detection Extronic AB ï Stockholm ï Sweden Patent no:s Europe , Sweden , Norway , Finland Voltage: Effect:. load: 230 VAC 50 Hz 9VA/ 5VA 250 V/5 A /relay Level switch NV2TDSI CNC Extronic AB Stockholm Sweden 30m for 230 V regulating0 Current for low level regulating:. Soft 40 ma Dim DSI v2.1 block Switch Det. 12 VDC Extronic Elektronik AB 46 (0)

5 for 230 V regulating Current for low level regulating:. 40 ma Level switch for 230 V regulating Current for low level regulating:. 40 ma 2 A 30 VDC Sensitivity Sensitivity CNC Wiring example with PD2200 IR detector Example is a canteen with manual control of lighting Canteen or conference room Precensdetector fittings IRdetector PD V C L1 N Level switch 2 tim Level switch NV2TDSI CNC 30m Extronic AB Stockholm Sweden For digital regulating of luminaires for 230 V regulating0 Current for low level regulating:. Soft 40 ma Dim v2.1 block Switch Det. 12 VDC Stabilized power supply supply EXE2000 EXE2000 Extronic AB ï Stockholm ï Sweden 15 & 17 = IN 230 V~ Primary Secondary 15 17=IN 230 V~ Primary Secondary & = = UT OUTPUT ~ Voltage: 13,65V Voltage: 13,65 11 & = = UT OUTPUT Current: 0,2 0,2 AA Current: 1,5 1,5 AA Placing a jumper between terminals 1 and 2 (blocking input) prevents the lighting from being switched on automatically. This wiring example is intended for a canteen with dimmable light fittings that have control, but can also be used in other similar premises. The lighting always has to be switched on by means of a pushbutton, and comes on at the high level (red), of around 80 per cent. When everyone has left, the lighting is automatically reduced to the base level, or low level, and is switched off completely after 1 2 hours. This time is set with the timer potentiometer (yellow). C NC TP 1 x 4 x 0,25 mm 2 Jumper Rectifire EXE2000 for switching lighting on/off manually. If the pushbutton is held in the lighting is dimmed. The lighting can also be switched off manually with the pushbutton. If someone enters the premises before the lighting has been switched off completely, the pushbutton has to be pressed again to return the lighting to the high level. Wiring example for stairway without detectors Automated stairway lighting for dimmable ballasts Stairway with natural light fittings C N O N L1 Rectifier EXE level 30% 1 tim Level switch NV2TDSI 30m Extronic AB Stockholm Sweden for 230 V regulating 0 Current for low level regulating:. Soft 40 ma Dim v2.1 block Switch Det. 12 VDC Stabilized power supply supply EXE2000 EXE2000 Extronic AB ï Stockholm ï Sweden 15 & 17 = IN 230 V~ Primary Secondary 15 17=IN 230 V~ Primary Secondary & = = UT OUTPUT ~ Voltage: 13,65V Voltage: 13,65 11 & = = UT OUTPUT Current: 0,2 0,2 AA Current: 1,5 1,5 AA This wiring example is intended for a stairway with dimmable light fittings with control. The lighting is switched on manually at the high level (red), around 80 per cent, by means of pushbuttons. After 15 minutes the lighting is reduced to the low level (blue), which is recommended to be set around per cent. If presence is not detected for an extended period the lighting is switched off entirely. This time can be adjusted between 0 2 hours with the timer potentiometer (yellow). This time should be set to be as long as possible, ideally 1 2 hours Extronic Elektronik AB 46 (0) With a resistor (4.7 kω) is connected in series, the lighting can only be switched on and stays on for 15 minutes. 4,7 kω This is an economical solution for controlling dimmable light fittings (). Most people who use the stairway will not press the button to increase the lighting to the level required by Swedish standards. They are able to find their way at the lower light level, which gives an added saving. See application 4B in the manual Energysaving detection technology handbook or at for examples of ideal solutions with dimmable ballasts.

6 2 A 30 VDC for 230 V regulating Current for low level regulating:. 40 ma Extended operation is similar to standard operation, but with the base level lighting fixed at 1 per cent. The low level and high level (red) potentiometer now have different functions: The lighting is switched on automatically at the level set by Extended operation the low level (blue) potentiometer, (recommended as 30 per cent). The high level, which is switched on by pressing a pushbutton, is set using the high level (red) potentiometer, (recommended as 80 per cent). The lighting can also be dimmed to the required level by holding the pushbutton in. Extended operation is activated by connecting a 10 kω resistor to the detector input; see the wiring diagram below. Note that, when power is first switched on, cannot sense the 10 kω resistor at the detector input if the detector senses presence at the same time, which it normally does. Auto Manual level Blue pot. 30% up to two hours. Rest level Red pot. 80% Base level lighting 1% (fixed setting) Switched off A gym hall or lunch room with natural light. fittings Application example One automatic and one manual lighting level (for presence detection or pushbutton operation) e.g. for a gym hall or lunch room. When the detector detects presence and there is insufficient natural light, the lighting is switched on automatically at the low level, which is recommended as 30 per cent. This lighting level is often adequate for exercising, dancing or during coffee breaks. The lighting level can be increased, for ball games or lunch, for example, by pressing the pushbutton. This switches the lighting to the higher level, recommended as 80 per cent. The lighting can also be dimmed to the required level by holding the pushbutton in Level switch NV2T 1 tim. detector sensor Sunlight When presence is no longer detected the lighting is dimmed to the base level (1 per cent). If no presence is detected for 1 2 hours the lighting is switched off completely. This time is set by the timer potentiometer (yellow). The lighting can also be switched off manually by pressing a pushbutton. When there is sufficient natural light from the windows the light sensor prevents the lighting from being switched on automatically. If no light sensor is installed the lighting is always switched on automatically when presence is detected. sensor IR detector PD2200 C N L1 Rectifire EXE2000 Additional applications with /NV 2T DSI (1C, 2C, 2D, 2F, 4F, 6A and 6D) can be found in the Energysaving detection technology handbook and on the website at Level switch NV2TDSI CNC Extronic AB Stockholm Sweden 30m for 230 V regulating0 Current for low level regulating:. Soft 40 ma Dim Breaking capacity per v2.1 block Switch Det. 12 VDC Stabilized power supply supply EXE2000 EXE2000 Extronic AB ï Stockholm ï Sweden 15 & 17 = IN 230 V~ Primary Secondary 15 17=IN 230 V~ Primary Secondary & = = UT OUTPUT ~ Voltage: 13,65V Voltage: 13,65 11 & = = UT OUTPUT Current: 0,2 0,2 AA Current: 1,5 1,5 AA C NC TP 1 x 4 x 0,25 mm kω Extended operation is enabled by adding a 10 kω resistor. for higher lighting level (80%). Several pushbuttons can be connected in parallel. 6 Extronic Elektronik AB 46 (0)

7 Commissioning Adjusting levels and times. As a standard solution the potentiometers should be adjusted to give the following minimum and maximum levels: level potentiometer base lighting ( blue) to 1 per cent = lowest possible (fully anticlockwise) or whatever setting the HF ballast permits or gives the desired level of comfort. level potentiometer normal lighting ( red) to highest, 80 per cent. A lux meter can be used to adjust the setting. To make adjustment of light levels easier the relevant level is switched on for a few seconds every time a level potentiometer is adjusted. The timer function ( yellow) controls the contactor and is used to limit the number of times the lighting is switched on. It is adjusted to 1 2 hours. A longer time means that the lighting is switched on fewer times each day. Longer time = less wear to the cathodes of fluorescent tubes. Adjust the delay for detector(s) to 1 2 minutes or slightly longer to suit wishes. This time determines how long the lighting remains at the higher level after presence was last detected. This time should therefore be kept as short as possible. It is very important that the settings for the installation are documented and that this is kept as a record that adjustment has been carried out according to the instructions. A form for documenting settings can be found in the Energysaving detection technology handbook or at en/manuals/. sensor (white). When a light sensor is connected it should be adjusted so that it prevents the lighting from being switched on when there is sufficient natural light. Dimmer rate ( Soft Dim, green). Should be set so that ramping up takes place at the required rate. The ramp down rate is fixed at around 20 seconds. A good base setting is to adjust the potentiometer to the one o clock position. Fluorescent tube burnin. New fluorescent tubes should be burned in to deliver their rated performance. Burnin entails operating the light fittings at 100 per cent power for 100 hours. There is a button on the circuit board that starts the burnin process for fluorescent tubes: A single press turns on the fluorescent tubes at for 100 hours. Pressing again interrupts the burnin process. During the burnin process the lighting can be switched on or off and dimmed manually. Technical specifications Current: level load, max. 100 ma Passive consumption: 45 ma at 13.8 VDC Voltage: VDC Number of light fittings: approx 100 Relay: Switching Switchoff delay: minutes Dimensions: 90 x 54 x 75 mm (3 modules) Optional equipment PD2200 presence detector Order no , PD2200 is a passive IR detector intended for presence detection. The electronics and software in the microprocessor of the PD2200 have been specially designed for presence detection. There is a lens library consisting of 41 lenses. The number 15 standard lens gives a detection area of 41 m x 41 m. EXE2000 rectifier Order no , A VDC (12 VDC) rectifier for mounting on a DIN rack that fits a standard enclosure and has a 1.5 A current limit and shortcircuit protection. LS10 light sensor Order no E, sensor for connecting to, etc. The light sensor monitors the light level in the premises. AD500/600 detector Order no /13091, AD500/600 are acoustic presence detectors for lighting control. These detectors detect presence by listening for sounds in two different frequency ranges and analysing the signals. The lighting is switched on by inaudible lowfrequency sound that is generated when a door is opened. The lighting is kept on as long as higher frequency sound such as footsteps and speech are detected. AD300 acoustic auxiliary detector Order no , AD300 is an auxiliary acoustic detector for controlling lighting in combination with an IR detector. The purpose of the detector is to switch on lighting when someone enters the premises by detecting the infrasound (lowfrequency sound) that is generated when a door is opened. This ensures that lighting is switched on in areas that the IR detector cannot see, such as concealed doorways, making the system more convenient. AD350 acoustic auxiliary detector Order no , AD350 is an auxiliary acoustic detector intended for controlling lighting in combination with an IR detector. It listens solely to a limited frequency range between 3 and 7 khz and switches on the lighting (or keeps it switched on) when sound is detected in this range, before the IR detector detects presence. The AD350 is often used to supplement IR detectors, to ensure that lighting remains on when people are present Extronic Elektronik AB 46 (0)

LEVEL SWITCH NP-3T DL v1.0 Installation instructions Order no E-no

LEVEL SWITCH NP-3T DL v1.0 Installation instructions Order no E-no LEVEL SWITCH v1. Installation instructions Order no. 13181 E-no. 13 6 81 Control that uses a light sensor Presence Power regulating up to two hours No presence Low level Blue knob1% Rest No presence Completely

More information

LOGIC MODULE EX-22 For lighting control with automatic regulation of light level

LOGIC MODULE EX-22 For lighting control with automatic regulation of light level LOGI MODULE For lighting control with automatic regulation of light level Order no: 366. Description is a logic module for controlling two lighting groups in one area, orintwo areas with one lighting group

More information

SENSA MRE DDM MR

SENSA MRE DDM MR 96239831 SENSA MRE DDM MR Contents Section Contents Page 1 Dimensional information 1 2 Description and operation 2 3 Wiring and fixing 3 4 Programming 6 5 Wiring diagrams 8 6 Detection pattern diagrams

More information

Sensors and Detectors

Sensors and Detectors 12/12/2017 Sensors and Detectors - Clipsal by Schneider Electric Sensors and Detectors Add sensors and detectors to make an environment smarter and more efficient. C-Bus sensors and detectors allow environmental

More information

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs. MWS6-DD-LV Product Guide Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC Overview The MWS6-DD-LV microwave presence detector provides automatic control of lighting loads with optional manual

More information

User Manual 120/240/300 Outdoor Motion Detector

User Manual 120/240/300 Outdoor Motion Detector User Manual 120/240/300 Outdoor Motion Detector Swiss Garde 4000 Warning! - Any work on the main power supply must only be completed by trained specialists. - The product must be installed in accordance

More information

False Ceiling HF Sensors

False Ceiling HF Sensors False Ceiling HF Sensors HC009S/EXT HC018V/EXT HC019V/EXT Applications Ideally suited to retrofit projects where the luminaire is too small to accomodate the sensor internally, this motion sensor can be

More information

Product Guide. Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Product Guide. Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. Product Guide LPCMPIRDSI Ceiling PIR presence detector DALI / DSI dimming Overview The LPCMPIRDSI PIR (passive infrared) presence detector provides automatic control of lighting loads with optional manual

More information

Direct Dim Microwave Presence/Absence Detector

Direct Dim Microwave Presence/Absence Detector Product Guide MWS3A-DD Direct Dim Microwave Presence/Absence Detector Contents Section Contents Page 1 Dimensional information 1 2 Description and operation 2 3 Wiring & Fixing 3 4 Installation 3 5 Fixing

More information

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs. MPAD-C-DALI-230V Product Guide Ceiling microwave presence detector DALI / DSI Overview The MPAD-C-DALI-230V microwave presence detector provides automatic control of lighting loads with optional manual

More information

Dec Wirsbo CoSy Radio. Installation and Operating Instructions

Dec Wirsbo CoSy Radio. Installation and Operating Instructions Dec. 2002 Wirsbo CoSy Radio Installation and Operating Instructions Contents 1. Overview... 3 2. Room thermostat... 3 2.1 Thermostat models... 3 2.2 Function... 4 2.3 Positioning... 4 2.4 Setting and limiting

More information

Honeywell ENERGY SAVINGS KIT

Honeywell ENERGY SAVINGS KIT ENERGY SAVINGS KIT 1. Application The Honeywell Energy Savings Kit reduces energy consumption by sending a dry contact signal to a Honeywell thermostat to change its set-point (increase in cooling mode)

More information

GE Lighting. Lighting Controls. DALI Digital Lighting Controls

GE Lighting. Lighting Controls. DALI Digital Lighting Controls GE ighting ighting Controls I Digital ighting Controls the I Protocol Multi-functional control of I-ready GE uminaires 1-1 to I converters available for analogue luminaires I CB Type 2 - complete programmable

More information

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver EBDSPIR-HB-DD Product Guide High bay PIR presence detector DALI / DSI dimming Overview The EBDSPIR-HB-DD PIR (passive infrared) presence detector provides automatic control of lighting loads with optional

More information

, ,

, , 796-2028, 796-2021, 796-2025 Batten mount PIR detectors Overview This series of miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional manual control

More information

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor.

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor. Product Guide EBDSM-DD Ceiling PIR presence detector DALI / DSI dimming Overview The EBDSM-DD PIR (passive infrared) presence detector provides automatic control of lighting loads with optional manual

More information

PRODUCT DATA AND INSTALLATION SHEET MWS5-SA STAND ALONE MINIATURE CEILING MOUNTED MICROWAVE PRESENCE DETECTOR

PRODUCT DATA AND INSTALLATION SHEET MWS5-SA STAND ALONE MINIATURE CEILING MOUNTED MICROWAVE PRESENCE DETECTOR 8. SPECIFICATION LOAD 6 Amps fluorescent and incandescent lighting. 3 Amps compact fluorescent lighting. 3 Amps low energy lighting. 3 Amps low voltage lighting (switch primary of transformer). Switch

More information

11,9. Ordering data. Max. cable length sensor head 1 basicdim ILD lx 150 lx m 1

11,9. Ordering data. Max. cable length sensor head 1 basicdim ILD lx 150 lx m 1 Compact dimensions for luminaire installation For up to 10 DSI or DALI devices (max. 5 per output channel) DALI/DSI output channels with adjustable negative offset from channel to channel 1 Ambient light

More information

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs. MWS3A-DD-LV Product Guide Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC Overview The MWS3A-DD-LV microwave presence detector provides automatic control of lighting loads with optional manual

More information

Tri-level Control HF Sensor

Tri-level Control HF Sensor Tri-level Control HF Sensor Standard Version Applications Occupancy detector with tri-level control suitable for indoor use. Suitable for building into the fixture: Office / Commercial Lighting Use for

More information

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver Product Guide EBDHS-AD-LT30 Ceiling PIR HS presence detector 1-10V, low temperature Overview The EBDHS-AD-LT30 PIR (passive infrared) presence detector provides automatic control of lighting loads with

More information

Integrated PIR detectors

Integrated PIR detectors EBMINT - Product Guide Integrated PIR detectors Overview The EBMINT series of miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional manual control

More information

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver Product Guide EBDSPIR-HB-AD High bay PIR presence detector 1-10V dimming Overview The EBDSPIR-HB-AD PIR (passive infrared) presence detector provides automatic control of lighting loads with optional manual

More information

luxcontrol lighting control system basicdim basicdim ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor

luxcontrol lighting control system basicdim basicdim ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor Product description Compact dimensions for luminaire installation For up to 10 DSI or LI devices (max. 5 per output channel)

More information

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs. MPAD-C-A-DALI-230V Product Guide Ceiling microwave presence detector DALI / DSI Overview The MPAD-C-A-DALI-230V microwave presence detector provides automatic control of lighting loads with optional manual

More information

Product Guide. Ceiling PIR HS presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Product Guide. Ceiling PIR HS presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PPAD-C-HB-DALI-230V Product Guide Ceiling PIR HS presence detector DALI / DSI dimming Overview The PPAD-C-HB-DALI-230V PIR (passive infrared) presence detector provides automatic control of lighting loads

More information

Analogue Dimming Microwave Presence/Absence Detector

Analogue Dimming Microwave Presence/Absence Detector Product Guide MWS3A-AD Analogue Dimming Microwave Presence/Absence Detector Contents Section Contents Page 1 Dimensional information 1 2 Description and operation 2 3 Wiring & Fixing 3 4 Installation 3

More information

1 Safety instructions. 2 Device components. Light Management Universal automatic switch m. Art.-No.: AS Operating instructions

1 Safety instructions. 2 Device components. Light Management Universal automatic switch m. Art.-No.: AS Operating instructions Art.-No.: AS..1280-1.. Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure to observe the instructions may cause

More information

Rectifier RC-series. Manual RC-series English MA doc. Manual Wall and 19 English

Rectifier RC-series. Manual RC-series English MA doc. Manual Wall and 19 English Rectifier RC-series Manual RC-series English Manual Wall and 19 English Presentation The RC-series is a rectifier for either directly powering the load or for use together with batteries. It is designed

More information

EBDHS-DD-LT30. Ceiling PIR HS presence detector DALI / DSI, low temperature. Product Guide. Overview. Features

EBDHS-DD-LT30. Ceiling PIR HS presence detector DALI / DSI, low temperature. Product Guide. Overview. Features EBDHS-DD-LT30 Product Guide Ceiling PIR HS presence detector DALI / DSI, low temperature Overview The EBDHS-DD-LT30 PIR (passive infrared) presence detector provides automatic control of lighting loads

More information

English. Italiano. Português. Françias. Español

English. Italiano. Português. Françias. Español DT AM Grade 3 Español Françias Português Italiano English High Ceiling Mount Detector Installation Guide English DT AM Grade 3 High Ceiling Mount Detector Installation Guide General Description The Industrial

More information

luxcontrol lighting control system basicdim basicdim ILD Compact control module with ambient light sensor and motion sensor

luxcontrol lighting control system basicdim basicdim ILD Compact control module with ambient light sensor and motion sensor ILD Compact control module with ambient light sensor and motion sensor Compact dimensions for luminaire installation For up to 10 DSI or DALI devices (max. 5 per output channel) 2 DALI/DSI output channels

More information

FR-A180 FR-A360. Occupancy detector. Use

FR-A180 FR-A360. Occupancy detector. Use 5 488 Occupancy detector with daylight sensor Occupancy detector with integral daylight sensor for demand-based control of HVAC systems and lighting. Adjustable switch-on and switch-off delay Adjustable

More information

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features Product Guide EBMPIR-MB Batten mount PIR detectors Overview The EBMPIR-MB series of miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional manual

More information

5, SE GÅNGHESTER,

5, SE GÅNGHESTER, KSUB Control and monitoring unit Valid from week of manufacture 48/2005 Description The KSUB is a control and monitoring unit designed to control various types of fire/smoke dampers and fans in a flexible

More information

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor TECHNICAL SPECIFICATIONS PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor Basic Features Line voltage version: 120-277VAC, 60Hz Low voltage version: 24VDC, requires separate class 2 power supply PIR sensor

More information

MWS5. Miniature Microwave Presence Detector (standalone) Product Guide. Overview. Features

MWS5. Miniature Microwave Presence Detector (standalone) Product Guide. Overview. Features Product Guide MWS5 Miniature Microwave Presence Detector (standalone) Overview The MWS5 series of miniature microwave presence detectors provide automatic control of lighting loads with optional manual

More information

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications LS-818-3 Descriptions Temco s Passive Infrared Occupancy Sensor is a low cost comercial and residential surface mount occupancy sensor. Advanced filtering reduces false triggering due to air movement and

More information

Built-in HF Sensor for High Bay

Built-in HF Sensor for High Bay Daylight Monitoring RX TM Synchronisation control Ambient daylight threshold Built-in HF Sensor for High Bay HC419VRC/R Tri-level Control With Synchronisation and Remote Control Applications Occupancy

More information

DEIF A/S. Technical Manual. Type EC-2 Engine Control Unit D. Technical Manual

DEIF A/S. Technical Manual. Type EC-2 Engine Control Unit D. Technical Manual Technical Manual Type EC-2 Engine Control Unit 4189340232D DEIF A/S Technical Manual DEIF A/S Tel.: (+45) 9614 9614 Frisenborgvej 33, DK-7800 Skive Fax: (+45) 9614 9615 Denmark E-mail: deif@deif.com Contents

More information

T7984 A,B,C Electronic Modulating Control Thermostats

T7984 A,B,C Electronic Modulating Control Thermostats T7984 A,B,C Electronic Modulating Control Thermostats FEATURES PRODUCT DATA APPLICATION These microprocessor-based thermostats provide proportional - integral (PI) individual room temperature control in

More information

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification Dual Technology Wall Mounted Occupancy Sensor Manual & Specification PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH LOCAL ELECTRICAL CODES Douglas Lighting Controls Page 1 December 16, 2013 1. INTRODUCTION

More information

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual PD154 & PD158 VIGILANTE II ANNUNCIATORS 8 Field Selectable Sequences All Common ISA Sequences 4 or 8-Point (Channel) Monitoring Free Replaceable Message Labels Type 4X, NEMA 4X, IP65 Front Universal Power

More information

Detector switch - Dual Tech

Detector switch - Dual Tech Page 1. Use.................................... 1 2. Technical characteristics................1 3. Dimensions............................ 2 4. Connection........................... 2 5. Installation...........................

More information

Trios Training Manual

Trios Training Manual Trios Training Manual Version 1.2, June 2002 TRIOS training-manual 1. 2 1 1. TRIOS SYSTEM INTRODUCTION... 2 The Trios Concept... 2 Trios Multi-functionality... 2 Trios Flexibility... 2 Trios Simplicity...

More information

LPC3BSP65 & LPC3BDP65

LPC3BSP65 & LPC3BDP65 Product Guide LPC3BSP65 & LPC3BDP65 Batten mount PIR detectors Overview The LPC3B series of miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional

More information

Reduce lighting energy costs with controls

Reduce lighting energy costs with controls Reduce lighting energy costs with controls Reduce energy costs. Support sustainability Get control of your lighting. Upgrading lighting systems to next-generation lighting technologies can deliver energy

More information

v3 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On feature

v3 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On feature DT-300 v3 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On feature Specifications Voltage...18-28VDC/VAC, half wave rectified AC Current Consumption...25

More information

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47)

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47) DIESEL ENGINE CONTROL UNIT DCU 205 - USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) 64 84 52 00 Fax: (+47) 64 84 52 12 office@auto-maskin.no - 1 - TABLE OF CONTENTS 1. INTRODUCTION TO THE DCU 205...4

More information

LPCMPIRM65 & LPCMPIRDSI65

LPCMPIRM65 & LPCMPIRDSI65 Product Guide LPCMPIRM65 & LPCMPIRDSI65 Luminaire high mount PIR detectors Overview The LPCMPIR PIR (passive infrared) presence detector provides automatic control of lighting loads with optional manual

More information

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features Product Guide PIR/INT & PIR/INT-D Batten mount PIR detectors Overview The PIR/INT & PIR/INT-D miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional

More information

compact office 24V compact office 24V Lux

compact office 24V compact office 24V Lux Presence detector compact office 24V compact office 24V Lux Art. Nr. 201 4 000 Art. Nr. 201 4 001 D F GB E I NL S N FIN DK Bedienungsanleitung 2 Notice d utilisation 22 Installation manual 42 Manual de

More information

Description FEATURES. l Innovative dual mount system requires only one sensor for either flush or surface mount applications

Description FEATURES. l Innovative dual mount system requires only one sensor for either flush or surface mount applications Simple Fit Switching Sensors 1.8m to 3m Cone-shaped detection pattern, 6m radius at mounting height 6.0m AC220~240V/50Hz MK Simple Fit Sensors offer cost effective presence detection for lighting control

More information

MODEL EUR -5A AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL

MODEL EUR -5A AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL MODEL EUR -5A AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL TABLE OF CONTENTS Product Overview... 2 Operation... 3 Installation... 5 Troubleshooting... 9 Ordering Information, Warranty and Service...10

More information

Ceiling PIR HS presence detector. Product Guide. Overview. Features

Ceiling PIR HS presence detector. Product Guide. Overview. Features Product Guide 796-2047 Ceiling PIR HS presence detector Overview The 796-2047 (passive infrared) presence detector provides automatic control of lighting loads with optional manual control. This is a high

More information

Sentry 4 Zone Alarm Panel User Manual

Sentry 4 Zone Alarm Panel User Manual TM TM Sentry 4 Zone Alarm Panel User Manual PLEASE NOTE: A 16Vac / 16VA Transformer MUST be used with this product. Contents 1. Introduction. 2. Programming a Remote. 3. Deleting all Remote s. 4. The siren

More information

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit D-TECT 2 GJD300 Quad PIR Movement Detector Package Contents Package Contains: 1 x D-Tect 2 1 x Drilling template for fixing holes 3 x 31.75mm wall plugs 3 x 31.75mm screws 2 x Spare Sliding Curtains 2

More information

3. Proper use. 4. Function. 1. Product characteristics. 2. Safety. Function description. Channel A light. Motion detector

3. Proper use. 4. Function. 1. Product characteristics. 2. Safety. Function description. Channel A light. Motion detector 307021 3. Proper use EN Motion detector themova P360-100 UP WH 1030600 themova P360-100 UP GR 1030601 The motion detector is intended for interior. The motion detector is eclusively intended for the use

More information

ECO-IR 360C NT. Presence detector. Art. Nr Bedienungsanleitung 2. Notice d utilisation 22. Installation manual 42

ECO-IR 360C NT. Presence detector. Art. Nr Bedienungsanleitung 2. Notice d utilisation 22. Installation manual 42 Presence detector ECO-IR 360C NT Art. Nr. 202 0 400 D F GB E I NL S N FIN DK Bedienungsanleitung 2 Notice d utilisation 22 Installation manual 42 Manual de instrucciones 62 Istruzioni per l uso 82 Gebruikershandleiding

More information

Infrared Ceiling Mount Sensor

Infrared Ceiling Mount Sensor Infrared Ceiling Mount Sensor LOS-CI Series LOS-CI- 0.0.06 The LOS-CI Series ceiling-mount passive infrared sensors can integrate into Lutron systems or function as standalone controls using a Lutron power

More information

03.03.mmm REV.2 09/01

03.03.mmm REV.2 09/01 03.03.mmm REV.2 09/01 Via del Lavoro, 80-40056 CRESPELLANO (Bologna) ITALY - ( +39 051/733.383 - Fax. +39 051/733.620 P.O. BOX, 150-40011 ANZOLA EMILIA (Bologna) - ITALY Power Factor Regulator cosφ V A

More information

Conventional Fire Detection

Conventional Fire Detection SECTI 4: page 1 Section 4: Conventional Fire Detection Contents System Architecture Control Panel Automatic & Manual Detection Manual Call Points Smoke Detectors Heat Detectors Beam Smoke Detectors Duct

More information

Technology. Occupancy & Vacancy Sensors & Timers. Technology. Occupancy & Vacancy Sensors & Timers L-2

Technology. Occupancy & Vacancy Sensors & Timers. Technology. Occupancy & Vacancy Sensors & Timers L-2 Passive Infrared Sensors (PIR) Using a patented fresnel lens which minimizes optical aberrations, each Legrand/Pass & Seymour PIR sensor breaks its coverage area into zones. Upon detecting an infrared

More information

D-Tect 2 GJD300 Quad PIR Movement Detector

D-Tect 2 GJD300 Quad PIR Movement Detector D-Tect GJD0 Quad PIR Movement Detector Package Contents 3. Package Contains: x D-Tect x Drilling template for fixing holes x Allen Key 3 x 3.75mm wall plugs 3 x 3.75mm screws x Spare Sliding Curtains x

More information

11,1 30. Ordering data

11,1 30. Ordering data ID Compact control module with ambient light sensor and motion sensor Compact dimensions for luminaire installation For up to 10 DSI or I ballasts I/DSI output channels with adjustable negative offset

More information

compact office 24V compact office 24V Lux

compact office 24V compact office 24V Lux Presence detector compact office 24V compact office 24V Lux Art. Nr. 201 4 000 Art. Nr. 201 4 001 D F GB E I NL S N FIN DK Bedienungsanleitung 2 Notice d utilisation 21 Installation manual 40 Manual de

More information

DYGIZONE GJD910 Lighting Controller & Enunciator

DYGIZONE GJD910 Lighting Controller & Enunciator DYGIZONE GJD910 Lighting Controller & Enunciator MASTER WIRING IDENTIFICATION Power up to the DygiZone and you will see: All the LED s (red,yellow,green and blue buttons) will flash All the LCD icons will

More information

0701 CO Light, HVAC, Monitoring, Brightness

0701 CO Light, HVAC, Monitoring, Brightness Using the application program Communication objects Product range: Product type: Manufacturer: Name: Order No.: Phys. sensors presence detector Siemens UP 258/21 presence detector 5WG1 258-2AB21 Functional

More information

ETNC24-FC-BAC-PIR-01 Owner s manual & Technician Settings

ETNC24-FC-BAC-PIR-01 Owner s manual & Technician Settings ETNC-FC-BAC-PIR- Rev. Index Operating instructions....- Turning the thermostat and OFF Selecting temperature scale Adjusting the Set point temperature (for set point and set points configurations) Selecting

More information

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications LS-818-3 Descriptions Temco s Passive Infrared Occupancy Sensor is a low cost comercial and residential surface mount occupancy sensor. Advanced filtering reduces false triggering due to air movement and

More information

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd. F-2000 PC and AO OUTPUT BOARDS INSTRUCTION MANUAL Blue-White R Industries, Ltd. 500 Business Drive Huntington Beach, CA 92649 USA Phone: 714-89-8529 FAX: 714-894-9492 E mail: sales@blue-white.com or techsupport@blue-white.com

More information

EBMHS (standard & slim-line PSU)

EBMHS (standard & slim-line PSU) Product Guide EBMHS (standard & slim-line PSU) Miniature HS PIR Presence Detector (luminaire fitting) Overview The EBMHS series of miniature PIR (passive infrared) presence detectors provide automatic

More information

AO Annunciator Module

AO Annunciator Module General Specifications GS48C43Z01-00E-N AO-543-01 Annunciator Module GENERAL Figure 1 This module has two independent annunciator circuits. The circuits handle fault signals and operator actions (acknowledge,

More information

SWITCHLITE MRE DDM ADJ

SWITCHLITE MRE DDM ADJ 96239889 SWITCHLITE MRE DDM ADJ Front features Mounting Bezel Back features Retaining Spring Power Input & Switched Output Connector (Channel 1) Sensor Lens which covers... Microwave Sensor IR Receiver

More information

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63 Fire Extinguishing Control Panel FS5200Е INSTRUCTION MANUAL Revision 8/01.17 Instruction Manual Page 1 1. 2. 3. 4. 4.1. 4.2. 4.2.1. 4.2.2. 4.2.3. 4.2.4. 4.2.5. 4.2.6. 4.2.7. 4.2.8. 4.2.9. 4.2.10. 4.2.11.

More information

ESSEX ENGINEERING CORPORATION

ESSEX ENGINEERING CORPORATION WATER/WASTEWATER TREATMENT CONTROL SYSTEMS AND SUBSYSTEMS 2000 SERIES CONTROL SYSTEMS: 2000 series are for surface mounting inside a control cabinet Model 2024 Electronic Alternator Duplex (two pump) pump

More information

Eco-sensors - PIR. Catalogue number(s): / / Use. 1. Use Technical characteristics (continued)

Eco-sensors - PIR. Catalogue number(s): / / Use. 1. Use Technical characteristics (continued) Page. Use..................................... 2. Technical characteristics................. 3. Dimensions.............................2 4. Connection.............................2 5. Removal................................3

More information

SMART BASIC BASIC-IR DAYLIGHT

SMART BASIC BASIC-IR DAYLIGHT LUXMATE Lighting Control System LUXMATE. The ing system for maximum quality and dimming convenience. SMART BASIC BASIC-IR DAYLIGHT The art of modern technology lies in making complicated things simple.

More information

Soft Start Series MP700 Solid State, Reduced Voltage

Soft Start Series MP700 Solid State, Reduced Voltage Metron Fire Pump Controls and Accessories Soft Start Series MP700 Solid State, Reduced Voltage Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s

More information

ELECTROPROJECT GTV-A POWER SUPPLY FOR DOOR MAGNETS

ELECTROPROJECT GTV-A POWER SUPPLY FOR DOOR MAGNETS ELECTROPROJECT POWER SUPPLY FOR DOOR MAGNETS Innovative and carefully thought out Always the right drive ELECTROPROJECT AANDRIJFTECHNIEK ElectroProject has evolved over the last 75 years from a technical

More information

Conventional Fire Alarm System 2014 V1.2

Conventional Fire Alarm System 2014 V1.2 Conventional Fire Alarm System 2014 V1.2 Product Overview Control Panel 2 Conventional Fire Panel GST102A 2 zone Fire panel GST104A 4 zone Fire panel GST108A 8 zone Fire panel GST116A 16 zone Fire Panel

More information

B.E.G. LUXOMAT. Find the right detector.

B.E.G. LUXOMAT. Find the right detector. B.E.G. LUXOMAT Find the right detector www.beg-luxomat.com B.E.G. B.E.G. SMARTPHONE APP The new B.E.G. remote control app 92726 Rapid programming by smartphone The B.E.G. remote control app is the easiest

More information

Intrusion Outdoor Protection Perimeter

Intrusion Outdoor Protection Perimeter Intrusion Outdoor Protection Perimeter Borders Commercial industrial Military base Correctional institution VIP Estates/Residences Communication Airports Warehouses Perimeter Sensors: the ideal solution

More information

CDR-AL Room CO 2 Traffic Light Alarm Units and Sensors

CDR-AL Room CO 2 Traffic Light Alarm Units and Sensors Product sheet SN1.402 Type CDR-AL CDR-AL Room CO 2 Traffic Light Alarm Units and Sensors CDR-AL sensors are designed to detect carbon dioxide concentration and temperature in the room spaces. The units

More information

SECTION LIGHTING CONTROLS

SECTION LIGHTING CONTROLS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 09 23 LIGHTING CONTROLS SPEC WRITER NOTE: 1. Delete between //----// if not applicable to project. Also, delete any other item or paragraph not applicable to

More information

MWS3A-PRM Product Guide

MWS3A-PRM Product Guide MWS3A-PRM Product Guide Microwave Presence/Absence Detector Contents Section Contents Page 1 Dimensional information 1 2 Description and operation 2 3 Wiring & Installation 3 4 Fixing - Flush 4 5 Fixing

More information

Application, Installation, Operation & Maintenance Manual

Application, Installation, Operation & Maintenance Manual APPROVED BY:JBJ PRESCIENT III FIRE ALARM & GAS EXTINGUISHING CONTROL PANEL Application, Installation, Operation & Maintenance Manual PAGE 1 of 43 CONTENTS 1. INTRODUCTION... 3 2. GENERAL DESCRIPTION...

More information

Connections, displays and operating elements C D E G H. Installing the control unit

Connections, displays and operating elements C D E G H. Installing the control unit 1 2 3 GB Control unit 0-10 V REG-K/3-gang with manual mode Operating instructions Art. no. MTN646991 ¼ DANGER Risk of fatal injury from electrical current. All work on the device should only be carried

More information

EBDSPIR-PRM-VFC & EBDSPIR-PRM-VFC-NC

EBDSPIR-PRM-VFC & EBDSPIR-PRM-VFC-NC Product Guide EBDSPIR-PRM-VFC & EBDSPIR-PRM-VFC-NC Ceiling PIR presence/absence detector Overview The EBDSPIR-PRM-VFC PIR (passive infrared) presence detector provides automatic control of lighting loads

More information

Type 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B

Type 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B PRODUCT BULLETIN SB 8001B Type 8001 ALARM ANNUNCIATOR TYPE8001 FEATURES 16 or 32 alarm points per flush mount enclosure Displays are backlit with long life LEDs and engraved to suit Dimmer controls built

More information

Tebis application software

Tebis application software 5 Tebis application software STCC530E 2-channel presence detector 360 A faire Product reference Description TP device RF devices TCC530E Bi-zone presence detector TCC530E Output module: Dimmer Loads connected

More information

4 & 8-POINT ANNUNCIATORS Instruction Manual

4 & 8-POINT ANNUNCIATORS Instruction Manual 4 & 8-POINT ANNUNCIATORS Instruction Manual 8 Field Selectable Sequences All Common ISA Sequences 4 or 8-Point (Channel) Monitoring Free Replaceable Message Labels Type 4X, NEMA 4X, IP65 Front Universal

More information

Emergency power automatics MS-2. High resistance to shock, vibrations and transients. All output are 2A relay contacts

Emergency power automatics MS-2. High resistance to shock, vibrations and transients. All output are 2A relay contacts Emergency power automatics Type EPOMATIC MS-2, EC-2 4921240002D MS-2 EC-2 DEIF A/S All necessary functions: - mains supervision - start/supervision/stop of diesel engine - control of circuit breakers and

More information

Lighting Control. Sensor Daylight 2. Daylight+Motion 3. Daylight+Motion+Control 4. Daylight+Motion+Control IP67 5

Lighting Control. Sensor Daylight 2. Daylight+Motion 3. Daylight+Motion+Control 4. Daylight+Motion+Control IP67 5 Lighting Control Sensor Daylight 2 Daylight+Motion 3 Daylight+Motion+Control 4 Daylight+Motion+Control IP67 5 Daylight SL01A Daylight+Motion+Control SM03A Daylight+Motion SM05 With the increasing interests

More information

Analog Annunciator Unit SACO 16 A3. Product Guide

Analog Annunciator Unit SACO 16 A3. Product Guide Issued: Aprill 1999 Status: Updated Version: C/20.03.2006 Data subject to change without notice Features Powerful, flexible and field-customizable 16-channel analog input signal annunciator unit A full

More information

Product Manual SZ1145

Product Manual SZ1145 Product Manual SZ114 General Purpose Monitor Communicating Controls Description The SZ114 is a microprocessor-based monitoring and alarm interface designed to monitor up to four 1000 Ω platinum temperature

More information

ABLOY DA460 SWING DOOR OPERATOR. Installation and commissioning manual

ABLOY DA460 SWING DOOR OPERATOR. Installation and commissioning manual ABLOY DA460 SWING DOOR OPERATOR Installation and commissioning manual APPROVALS / STANDARDS 73/23/EEC (Low Voltage directive) 93/68/EEC (Low Voltage directive) 89/336/EEC (EMC directive) Statement of fire

More information

MANDATORY MEASURES MANDATORY LIGHTING CONTROLS (a) Area Controls: Manual controls that control lighting in each area separately

MANDATORY MEASURES MANDATORY LIGHTING CONTROLS (a) Area Controls: Manual controls that control lighting in each area separately MANDATORY MEASURES INDOOR LIGHTING CONTROLS (Reference: Sub-Chapter 4, Section 130.1) MANDATORY LIGHTING CONTROLS 1. 130.1 (a) Area Controls: Manual controls that control lighting in each area separately

More information

Xenex Conventional Fire Detection & Alarm System

Xenex Conventional Fire Detection & Alarm System SECTI 4: page 1 Section 4: Xenex Conventional Fire Detection & Alarm System SECTI 4: page 3 Xenex system architecture Beam Transmitter Beam Receiver End of Line Call Point Smoke Detector Smoke Detector

More information