TENDER NOTICE NO. 07/2012 INVITATION FOR BIDS / NIT
|
|
- Gregory Robbins
- 5 years ago
- Views:
Transcription
1 CSIR-Indian Institute of Petroleum (Council of Scientific & Industrial Research) P.O:I.I.P., MOHKAMPUR, DEHRADUN (UA) INDIA Ph (D), & Fax , Website: ISO 9001 Regd. Institute TENDER NOTICE NO. 07/2012 INVITATION FOR BIDS / NIT 1. Sealed tenders under two bids system ( part-i Technical bid along with EMD and part II Price bid) are invited from the Indian / Foreign manufacturers/ Authorised Distributors or Indian Agents for the supply, installation and commissioning of the following equipments:- S.No Tender No. Description of items Qty Single/ Double bid 1. PUR/1/12-13/ AB-VVDN/ 249 & 317/PO: Gas Chromatograph with FID andtcd Specifications: Hydrocarbons and generic compounds analysis by Flame Ionization Detector (FID) and analysis of gases by Thermal Conductivity Detector (TCD). 2 Nos of split/splitless injectors with provision for on-line/off line analysis using 6-port automatic heated gas sampling valve with 0.25, 0.5, 1.0 ml loop operated series for TCD and FID and separately, with computer, printer and all accessories as per detailed specifications attached. "Detailed specification as per Annexure-A" Bid Security EMD) (in Indian Rupees) Two Double 1,00, (One Lakh only) 2. Interested Bidders may obtain further information from the office of the Controller of Stores & Purchase/Stores & Purchase Officer, Indian Institute of Petroleum, Mohkampur, Haridwar Road, Dehradun , India, Phone No.: Complete Standard bid document may be downloaded by any interested bidder directly from our website free of cost. 4. A Pre-bid Conference will be held Monday on at am hours (IST). All prospective bidders are requested to kindly submit their queries to the address indicated above so as to reach 2.00 pm latest by The bids must reach this office on or before (extended due date ) upto 14:30 hours (IST) and shall be opened on same day at 15:00 hours (IST). 6. All bids must be accompanied by a bid security as specified above and must be delivered to the above office at the date and time indicated above. Bids will be opened in the presence of Bidders' representatives who choose to attend on the specified date and time. In the event of the date specified for bid receipt and opening being declared as a closed holiday for purchaser s office, the due date for submission of bids and opening of bids will be the following working day at the appointed time. 7. The Director, Indian Institute of Petroleum, Dehradun reserves the right to accept any or all tenders either in part or in full or to split the order without assigning any reasons there for. Stores & Purchase Officer 1
2 ANNEXURE-A Technical Specifications of Gas Chromatograph with FID and TCD Quantity Required : Two Nos.* Detailed Specifications Gas Chromatograph with FID and TCD Main Unit With multi ramp (more than 15) temperature programming and advanced electronic pneumatic control (EPC)/electronic flow control (EFC) for carrier and detector gas supply and capable of providing round the clock productivity. Highly precise retention time repeatability (< 0.008%) and area repeatability (< 1%RSD) Full EPC for all inlets and detectors. Injectors 2 no of PTV split/splitless capillary injection port(1no port for TCD and FID to connect series and 1 no port for FID which connecting in series for offline use ) maximum temperature 400 o C, with electronic pressure control for carrier gas and split flow, pressure range psi. temperature programming from ambient to 400 o C. Provision for connecting narrow bore and wide bore fused silica capillary columns. 1 no of packed purge injection port for offline for second TCD. All injection ports should be independently heated. 6-port automatic heated gas sampling valve for on-line analysis with 0.25, 0.5ml and 1 ml loop using GC Transfer Line from a micro reactor (to reduce high pressure to ambient pressure) Oven Temperature range ambient to 450 o C. Multi ramp (more than 18) temperature programming and plateaus with high accuracy, Temperature ramp rate 0.1 to 100 o C per minute or better Temperature set-point resolution should be 1 o C. Fastest cooling down rate for oven (less than 5 minutes for cooling from 400 to 50 o C). Stability & Accuracy: ±0.1 o C Control Through GC keyboard and PC software independently. Full EPC (Electronic Pneumatics Control) for inlets and detectors Detectors One high sensitivity Flame Ionization Detector FID (series connected) should be connectable to capillary column. Auto-ignition, auto-detection and re-ignition features. Maximum temperature of FID should be 450 C or better Detectivity should be 2 pg C/sec or lessthan. Linear dynamic range should be 10 7 or better Flame-out detection/auto re-ignition: standard One Thermal Conductivity Detector (TCD) with pressure safety switch. Maximum temperature of TCD should be 400 C or better Detectivity should be 400 pg tridecane /ml with He carrier or better Linear dynamic range should be 10 5 or better Filament protection: standard Air/He and hydrogen lines should have separate controls for both detectors. Alarm Alarm facility for heater, sensor and gas flow faults. 2
3 Data System Work station with Core2Duo computer with provision for dual channels for the simultaneous collection of data. Software should be M S 32 bit software Windows XP or Vista based and should be capable of report generation through multi-tasking window (complete environment control through software) and data processing with provision for offline data processing. Software should be capable of doing all operations required for running the instrument (complete instrument control through software/pc) Chromatography software The Chromatography software should be a client server based Chromatography data system supporting LIMS integration. The software should be able to acquire data from all the detectors and should have a single point control of all gas chromatographic parameters. The software should have the facility for interactive graphics, tool bar facility for online editing, recalculation, batch data processing, overlay, peak integration, S/N (signal to noise) ratio, programmable integration control, baseline compensation, options for continuous averaging of calibration data, weighted regression etc. All standard chromatographic parameters for qualitative and quantitative analysis should be available. Back-up for all softwares should be provided. Computer details Desk top computer system Core i5(with Turbo Boost), 3.4 GHz, 4.0 GB RAM, 500 GB hard disk, 16X DVD, CD, Combo drive,usb multimedia keyboard, optical USB mouse, 19 LCD-TFT color monitor with latest windows Windows 7 Professional/Windows 8 ( 64 bit) Ultimate and CD back-up from standard supplier like IBM/HP etc. USB port and other standard features. Heavy duty high resolution HP Laser Jet P1606dn printer Purifiers and traps For nitrogen, helium (carrier gas lines) for removing moisture, hydrocarbons, oxygen and other gases in series. For detector gas supplies i.e. for hydrogen and air lines, traps for removing moisture and hydrocarbons. Analytical Columns Capillary columns 1. Column material: 100% Dimethyl polysiloxane, Nonpolar (length 30 meter, 0.53mm, 3.00 u) 2. Column material: Polyethylene Glycol, polar (length 30 meter, 0.53mm, 3.00 u) 3. Column for separation of peremenent gases, H 2, H 2 O and C1 to C5, C6+ Hydrocarbons using TCD and FID Graphite ferule set of 0.53mm, 0.32 mm and 0.22 mm each 2 no. pack Packed columns for GC 1. Separation of N 2, O 2, CO 2, CO, H 2 O and C1-C4 hydrocarbons (Porapak Q, Porapak N, Molecular Sieve, Chromosorb PAW) Cone and ferule (1/4" and1/8") set for packed column 2 no. pack Gas/liquid Syringes Gas tight syringe for gas samples for 100 µl/ 2mL 20 no. each 3
4 Liquid syringe for liquid samples for 10 µl 20 no.each Complete GC Installation KIT required at our site Installation accessory kit, complete with SS 316 tubing, spanners, metal tube cutter, screwdriver, wrench, snoop leak detector, fuses, ferrules, nuts, fuses, septa, jet tool etc. Guarantee At least 24 months comprehensive guarantee from the date of commissioning Training Comprehensive user/maintenance training should be there Complete Installation and Demonstration along with standard /lab reference Detailed circuit diagram, service manual and operation manual to be provided Recommended list of spares for three years. Stores & Purchase Officer 4
5 MINUTES OF MEETING Sub: Pre bid Technical Presentation on Notice No. 07/2012 for PUR/1/12-13/AB-VVDN/249 & 317/PO and PUR/1/12-13/SKM/346/PO Date: 21st January, 2013 at IIP, Dehradun Present: Dr. S. M. Nanoti (Chairman), Dr. S. K. Maity, Dr. Anil K. Sinha, Dr. VVDN Prasad, Jagdish Kumar, Poonam Gupta and Dr. A. Bordoloi Presented by:s. K. Mohanty (Hydrocarbon Solution), A. Tyagi (Bruker) and, A. Rathore (Dani Intruments) The following points have been raised 1. We have discussed three GC (one for SK Maity, one for VVDN Prasad and one for Ankur) in pre bid meeting with three vendors. 2. We have explained our requirements to all the vendors. 3. After discussion with the three vendors we have finalised our technical specifications. 4. We have also made few changes as follows SKM (PUR/1/12-13/SKM/346/PO) a. pressure range for injector was changed from 0 to 150 psi to 0 to 100 psi and maximum temperature for injector was changed from 450 to 400 O C or more. One packed injector port was replaced by GSV. b. One detector for sulfur, nitrogen and phosphorous has replaced by sulphur and nitrogen detector. c. We have made clear clarification of the automated valve in the detail way d. Packed column has been modified as high temperature packed column. VVDN Prasad (PUR/1/12-13/AB-VVDN/249 & 317/PO) e. pressure range for injector was changed from 0 to 150 psi to 0 to 100 psi. One packed injector port was replaced by GSV. f. Two TCD and one FID have been finalized. Ankur (PUR/1/12-13/AB-VVDN/249 & 317/PO) g. pressure range for injector was changed from 0 to 150 psi to 0 to 100. One packed injector port was replaced by GSV. h. Two FID and one TCD have been finalized. Stores & Purchase Officer 5
6 REVISED DETAILED TECHNICAL SPECIFICATIONS AFTER PRE-BID MEETING HELD AT IIP, DEHRADUN ON DUE DATE Submission of bids by 2.30 PM Opening of bids at 3.00 PM 6
7 PUR/1/12-13/VVDN/317/PO: Dt: Revised Detailed Specifications Gas Chromatograph with FID and TCD 1 No. Main Unit With multi ramp (more than 15) temperature programming and advanced electronic pneumatic control (EPC)/electronic flow control (EFC) for carrier and detector gas supply and capable of providing round the clock productivity. Highly precise retention time repeatability (< 0.008%) and area repeatability (< 1%RSD) Full EPC s for all inlets and detectors. Injectors 1 no of GSV and 1 no of PTV (GSV port for TCD and FID to connect in series and PTV port for TCD) maximum temperature 400 o C, with electronic pressure control for carrier gas and split flow, pressure range psi. Temperature programming from ambient to 400 o C. Provision for connecting narrow bore and wide bore fused silica capillary columns. 1 no Split/Splitless Capillary injection port to be connected to either to TCD or TCD+FID in series All injection ports should be independently heated. 6-port automatic heated gas sampling valve for on-line analysis with 0.25, 0.5ml and 1 ml loop using GC Transfer Line from a micro reactor (to reduce high pressure to ambient pressure) Oven Temperature range ambient to 450 o C Multi ramp (more than 18) temperature programming and plateaus with high accuracy, Temperature ramp rate 0.1 to 100 o C per minute or better Temperature set-point resolution should be 1 o C. Fastest cooling rate for oven (less than 5 minutes cooling from 400 to 50 o C). Stability & Accuracy: ±0.1 o C Control Control through GC keyboard and PC software independently. Full EPC (Electronic Pneumatics Control) for inlets and detectors Detectors One high sensitivity Flame Ionization Detector FID connected in series should be connected to capillary column. Auto-ignition, auto-detection and re-ignition features. Maximum temperature of FID should be 450 C or better Detectivity should be 2 pg C/sec or less. Linear dynamic range should be 10 7 or better Flame-out detection/auto re-ignition: standard Two Thermal Conductivity Detectors (TCD) with pressure safety switch. Maximum temperature of TCD should be 400 C or better Detectivity should be 400 pg tridecane /ml with He carrier or better Linear dynamic range should be 10 5 or better Filament protection: standard Air/He and hydrogen lines should have separate controls for both detectors. 7
8 Alarm Alarm facility for heater, sensor and gas flow faults. Data System Work station with Corei5 and above computer with provision for dual channels for the simultaneous collection of data. Software should be Windows 7 (64 bit with DVD ) based and should be capable of report generation through multi-tasking window (complete environment control through software) and data processing with provision for offline data processing. Software should be capable of doing all operations required for running the instrument (complete instrument control through software/pc) Chromatography software The Chromatography software should be a client server based Chromatography data system supporting LIMS (Laboratory Information Management System) integration. The software should be able to acquire data from all the detectors and should have a single point control of all gas chromatographic parameters. The software should have the facility for interactive graphics, tool bar facility for online editing, recalculation, batch data processing, overlay, peak integration, S/N (signal to noise) ratio, programmable integration control, baseline compensation, options for continuous averaging of calibration data, weighted regression etc. All standard chromatographic parameters for qualitative and quantitative analysis should be available. Back-up for all software s should be provided. Computer details Desk top computer system Core i5(with Turbo Boost), 3.4 GHz, 4.0 GB RAM, 500 GB hard disk, 16X DVD, CD, Combo drive, USB multimedia keyboard, optical USB mouse, 19 LCD-TFT color monitor with latest windows Windows 7 Professional/Windows 8 ( 64 bit) Ultimate and CD back-up from standard supplier like IBM/HP etc. USB port and other standard features. HP Laser Jet Pro M1136 MFP printer Purifiers and traps Purifiers and traps for nitrogen, helium carrier gas lines for removing moisture, hydrocarbons, oxygen and other gases in series. Traps for removing moisture and hydrocarbons from hydrogen and air gas lines for detector. Analytical Columns Capillary columns 4. Column material: 100% Dimethyl polysiloxane, Nonpolar (length 30 meter, 0.53mm, 3.00 u) 5. Column material: Polyethylene Glycol, polar (length 30 meter, 0.53mm, 3.00 u) 6. Column for separation of peremenent gases, H 2, H 2 O and C1 to C5, C6+ Hydrocarbons using TCD and FID Graphite ferule set of 0.53mm, 0.32 mm and 0.22 mm each 2 no. pack Packed columns for GC 2. Separation of N 2, O 2, CO 2, CO, H 2 O and C1-C4 hydrocarbons (Porapak Q, Porapak N, Molecular Sieve, Chromosorb PAW) Cone and ferule (1/4" and1/8") set for packed column 2 no. pack 8
9 Gas/liquid Syringes Gas tight syringe for gas samples for 100 µl/ 2mL 20 no. each Liquid syringe for liquid samples for 10 µl 20 no.each Complete GC Installation KIT required at our site Installation accessory kit, complete with SS 316 tubing, spanners, metal tube cutter, screwdriver, wrench, snoop leak detector, fuses, ferrules, nuts, fuses, septa, jet tool heaters and sensors etc. Guarantee At least 24 months comprehensive guarantee from the date of commissioning Training Comprehensive user/maintenance training should be there Complete Installation and Demonstration along with standard /lab reference Detailed circuit diagram, service manual and operation manual to be provided Recommended spares for three years. (Stores & Purchase Officer) 9
10 PUR/1/12-13/AB/249/PO: Dt: Revised Detailed Specifications Gas Chromatograph with FID and TCD 1 No. Main Unit With multi ramp (more than 15) temperature programming and advanced electronic pneumatic control (EPC)/electronic flow control (EFC) for carrier and detector gas supply and capable of providing round the clock productivity. Highly precise retention time repeatability (< 0.008%) and area repeatability (< 1%RSD) Full EPC for all inlets and detectors. Injectors 1 no of PTV and 1 no split/splitless capillary injection port(ptv port for TCD and FID series connected, and split/splitless port for FID).Maximum temperature 400 o C, with electronic pressure control for carrier gas and split flow, pressure range psi. temperature programming from ambient to 400 o C. Provision for connecting narrow bore and wide bore fused silica capillary columns. 1 no gas sampling value to be connected to either to FID or TCD+FID in series. All injection ports should be independently heated. 6-port automatic heated gas sampling valve for on-line analysis with 0.25, 0.5ml and 1 ml loop using GC Transfer Line from a micro reactor (to reduce high pressure to ambient pressure) Oven Temperature range ambient to 450 o C. Multi ramp (more than 18) temperature programming and plateaus with high accuracy, Temperature ramp rate 0.1 to 100 o C per minute or better Temperature set-point resolution should be 1 o C. Fastest cooling down rate for oven (less than 5 minutes for cooling from 400 to 50 o C). Stability & Accuracy: ±0.1 o C Control Through GC keyboard and PC software independently. Full EPC (Electronic Pneumatics Control) for inlets and detectors Detectors Two no high sensitivity Flame Ionization Detector FID connected in series should be connected to capillary column. Auto-ignition, auto-detection and re-ignition features. Maximum temperature of FID should be 450 C or better Detectivity should be 2 pg C/sec or lessthan. Linear dynamic range should be 10 7 or better Flame-out detection/auto re-ignition: standard One Thermal Conductivity Detector (TCD) with pressure safety switch. Maximum temperature of TCD should be 400 C or better Detectivity should be 400 pg tridecane /ml with He carrier or better Linear dynamic range should be 10 5 or better Filament protection: standard Air/He and hydrogen lines should have separate controls for both detectors. 10
11 Alarm Alarm facility for heater, sensor and gas flow faults. Data System Work station with Core i5 and above computer with provision for dual channels for the simultaneous collection of data. Software should be Windows 7 (64 bit with DVD ) based and should be capable of report generation through multi-tasking window (complete environment control through software) and data processing with provision for offline data processing. Software should be capable of doing all operations required for running the instrument (complete instrument control through software/pc) Chromatography software The Chromatography software should be a client server based Chromatography data system supporting LIMS (Laboratory Information Management System) integration. The software should be able to acquire data from all the detectors and should have a single point control of all gas chromatographic parameters. The software should have the facility for interactive graphics, tool bar facility for online editing, recalculation, batch data processing, overlay, peak integration, S/N (signal to noise) ratio, programmable integration control, baseline compensation, options for continuous averaging of calibration data, weighted regression etc. All standard chromatographic parameters for qualitative and quantitative analysis should be available. Back-up for all softwares should be provided. Computer details Desk top computer system Core i5(with Turbo Boost), 3.4 GHz, 4.0 GB RAM, 500 GB hard disk, 16X DVD, CD, Combo drive,usb multimedia keyboard, optical USB mouse, 19 LCD-TFT color monitor with latest windows Windows 7 Professional/Windows 8 ( 64 bit) Ultimate and CD back-up from standard supplier like IBM/HP etc. USB port and other standard features. HP Laser Jet Pro M1136 MFP printer Purifiers and traps For nitrogen, helium (carrier gas lines) for removing moisture, hydrocarbons, oxygen and other gases in series. For detector gas supplies i.e. for hydrogen and air lines, traps for removing moisture and hydrocarbons. Analytical Columns Capillary columns 1. Column material: 100% Dimethyl polysiloxane, Nonpolar (length 30 meter, 0.53mm, 3.00 u) 2. Column material: Polyethylene Glycol, polar (length 30 meter, 0.53mm, 3.00 u) 3. Column for separation of peremenent gases, H 2, H 2 O and C1 to C5, C6+ Hydrocarbons using TCD and FID Graphite ferule set of 0.53mm, 0.32 mm and 0.22 mm each 2 no. pack Packed columns for GC 1. Separation of N 2, O 2, CO 2, CO, H 2 O and C1-C4 hydrocarbons (Porapak Q, Porapak N, Molecular Sieve, Chromosorb PAW) Cone and ferule (1/4" and1/8") set for packed column 2 no. pack 11
12 Gas/liquid Syringes Gas tight syringe for gas samples for 100 µl/ 2mL 20 no. each Liquid syringe for liquid samples for 10 µl 20 no.each Complete GC Installation KIT required at our site Installation accessory kit, complete with SS 316 tubing, spanners, metal tube cutter, screwdriver, wrench, snoop leak detector, fuses, ferrules, nuts, fuses, septa, jet tool heaters and sensors etc. Guarantee At least 24 months comprehensive guarantee from the date of commissioning Training Comprehensive user/maintenance training should be there Complete Installation and Demonstration along with standard /lab reference Detailed circuit diagram, service manual and operation manual to be provided Recommended list of spares for three years. (Stores & Purchase Officer) 12
Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment
www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL 001.847.913.0777 for Refurbished & Certified Lab Equipment Agilent 6890N Network Gas Chromatograph Chromatographic Performance* Retention
More informationSCION 436-GC. Dimensions and Weights
SCION 436-GC Specification Sheet Dimensions and Weights Height*: 57 cm (22.5 in.), Width: 32 cm (13.0 in.), Depth: 61 cm (24.0 in.) Weight*: 26.8 kg (59lb) * Typical values Environmental Conditions Operating
More informationChemtron Science Laboratories Pvt. Ltd.
Chemtron Science Laboratories Pvt. Ltd. To, INTRODUCTION TO CSL GAS CHROMATOGRAPHS COMPANY PROFILE Chemtron Science Laboratories Pvt. Ltd. is an ISO 9001: 2000 by BSI, a part of fastest growing industry
More informationGas Chromatography (GC-342)
Gas Chromatography (GC-342) Wide range of application petrol-chemistry, environment protection, epidemic prevention, pharmacology, scientific research, etc. Updated Technology with high accuracy Self-diagnostic
More informationINDIAN INSTITUTE OF SCIENCE EDUCATION AND RESEARCH PUNE
INDIAN INSTITUTE OF SCIENCE EDUCATION AND RESEARCH PUNE CLARIFICATION ON TENDER NUMBER - IISER-PUR-0284-17 ITEM DESCRIPTION- PROCUREMENT OF GRAPHITE-FURNACE ATOMIC ABSORPTION SPECTROMETER WITH CHNS/O ANALYZER
More informationPerkin Elmer Clarus 500 Gas Chromatograph
IET International Equipment Trading, Ltd. www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Perkin Elmer Clarus 500 Gas Chromatograph
More informationTechnical specifications of FT-IR Spectrometer
Technical specifications of FT-IR Spectrometer We would like to buy a FT-IR spectrometer which has to be integrated with a Gas Chromatograph with the following technical specifications. 1. The spectrometer
More informationCALIDUS tm the Modular micro Gas Chromatograph
CALIDUS tm the Modular micro Gas Chromatograph Sample Processing Unit Plug & Play Programmed Temperature Column Modules Plug & Play Detector Modules Flame Ionization Thermal Conductivity A CALIDUS micro
More informationFile No. 28(1192)/2017/Pur Date: 19/06/2018
File No. 28(1192)/2017/Pur Date: 19/06/2018 Revised Technical Specifications and Clarifications issued after the Pre-Bid Conference Dated 08.06.2018 for SUPPLY, INSTALLATION AND COMMISSIONING OF PARTICLE
More informationFIXED GAS ANALYZER (FGA)
Gas Chromatography FIXED GAS ANALYZER (FGA) Productivity remains the primary goal of most work environments. Utilizing a gas chromatographic system capable of performing multiple analyses on a series of
More informationHISTORY OF VARIAN CAPILLARY INJECTORS
HISTORY OF VARIAN CAPILLARY INJECTORS by Randall Bramston-Cook Lotus Consulting 5781 Campo Walk Long Beach, Ca 90803 310/569-0128 714/898-7461 Fax and Herb Neumann Varian, Inc. 2700 Mitchell Drive Walnut
More informationSelecting the right generator for your GC system. By Ed Connor, GC Product Specialist, Peak Scientific Instruments Ltd
Selecting the right generator for your GC system By Ed Connor, GC Product Specialist, Peak Scientific Instruments Ltd Selecting the right generator for your GC system Gas generators offer a guaranteed
More informationAnalyze IT. Process Gas Chromatograph. PGC2000 Series
Process Gas Chromatograph PGC2000 Series PGC2000 Series PGC2002 Process Distillation PGC2003 PNA PGC2005 Temperature Programmed GC PGC2007 Fuel Sulfur Analyzer PGC2008 Olefins Analyzer PGC2009 Fast TP
More informationPOPULAR CONFIGURATION GCs Cryosulfur GC. System Overview
System Overview The SRI CryoSulfur GC comes with everything you need to detect low-level sulfur compounds in gas samples. Since some sulfur compounds do not trap well, the CryoSulfur GC uses the CryoCooler
More informationNexis GC-2030 Specifications
Gas Chromatograph C184-E042A Chromatography System Nexis GC-2030 opens up an entirely new chapter in Shimadzu's long history with gas chromatographs. It showcases some of the best specifications on the
More informationProcess Gas Chromatograph
Product Data Sheet RAI-PDS-GC-1000A June 2009 Model 1000A Process Gas Chromatograph Emerson Process Management offers a complete line of gas chromatographs specifically designed for process applications.
More informationRecent Improvements in Process GC Instrumentation
ISA Houston, TX Oct., 15 2003 Recent Improvements in Process GC Instrumentation Dr. Jack Driscoll PID Analyzers, LLC copyright 2000-2006 PID Presentation Objectives A new Process GC has been developed
More informationProcess and Air Monitoring. Online GC systems for continuous monitoring of organic compounds in air and gaseous samples
Process and Air Monitoring Online GC systems for continuous monitoring of organic compounds in air and gaseous samples For 35 years AMA Instruments has developed and manufactured analytical devices and
More informationProcess Gas Chromatograph
A I T Applied Instrument Technologies FXi Series5 PRODUCT SPECIFICATIONS Process Gas Chromatograph PSS FXI-S5 The FXi Series5 Process Gas Chromatograph (PGC) continuously analyzes, measures, and reports
More informationANNEX I. Technical specifications for: Supply of various Trace Explosive Detection Systems
EUROPEAN COMMISSION JOINT RESEARCH CENTRE Institute for Reference Materials and Measurements (Geel) ANNEX I Technical specifications for: Supply of various Trace Explosive Detection Systems TABLE OF CONTENTS
More information22 The Flame Ionization Detector
22 General Information FID pneumatics Special considerations Conditions that prevent the detector from operating Detector shutdown Jets Automatic reignition Lit offset Procedure: Changing the auto-reignite
More informationFPD - Flame Photometric Detector
FPD - Flame Photometric Detector FPD Overview - The FPD detector is can be configured for 2 modes of operation, one is highly selective for Sulfur compounds and the other mode highly selective for Phosphorus
More informationChemistry Instrumental Analysis Lecture 29. Chem 4631
Chemistry 4631 Instrumental Analysis Lecture 29 Gas Chromatography Detectors Gas Chromatography Monitors the column effluent and produces an electrical signal that is proportional to the amount of analyte
More informationAgilent 7890A Network Gas Chromatograph
Agilent 7890A Network Gas Chromatograph Data Sheet Chromatographic Performance* Retention time repeatability < 0.008% or < 0.0008 min Area repeatability < 1%RSD The Agilent 7890A is a state-of-theart gas
More information931D Style B Process Gas Chromatograph
Product Specifications PSS 6-4N1 D 931D Style B Process Gas Chromatograph The new 931D Style B Process Gas Chromatograph continuously analyzes, measures and reports the concentration of components in process
More informationSRI 8610C GC for PCB in Transformer Oil Analysis November 2014
The SRI 8610C Gas Chromatograph ( GC ) is installed on any bench top. When the red lid is raised, you can see the column oven, injector ( on-column type ), detector ( DELCD ) and gas stream dryer. The
More informationTYPES AND APPROPRIATE INJECTORS
SRI offers a wide variety of GC injectors and injection systems. Up to five injectors may be mounted simultaneously on the Model 8610C or 8610D. The Model 310 will accommodate a single On-column, Heated
More informationSimplicity. Reliability. Performance. Stratum. Automated VOC Sample Prep System
Simplicity Reliability Performance Stratum Automated VOC Sample Prep System The Stratum Purge and Trap Concentrator (PTC) is a sample preparation instrument used to remove Volatile Organic Compounds (VOCs)
More informationUNITY 2 TM. Air Server Series 2 Installation Manual. Version September 2012
UNITY 2 TM Air Server Series 2 Installation Manual Version 1.12 September 2012 1. Installation...2 1.1. Tools required...2 1.2. Procedure...2 1.3. Requirement for a sample pump (U-ASPMP1 / U-ASPMP2)...8
More informationGC Injectors. GC Injectors
SRI offers a wide variety of GC injectors and injection systems. Up to five injectors may be mounted simultaneously on the Model 8610C or 8610D. The Model 310 will accommodate a single On-column, Heated
More informationAromatics and Oxygenates in Gasoline June2018
SRI has configured in a single GC two common tests performed on gasoline. The first test is a a simplified version of ASTM 4815, oxygenates in gasoline. The second test is a simplified version of ASTM
More informationProcess Gas Chromatograph
Product Data Sheet PDS 103-1000.A01 December 2005 Model 1000 Process Gas Chromatograph Emerson Process Management offers a complete line of gas chromatographs specifically designed for process applications.
More informationNOTICE INVITING TENDERS FOR THE PURCHASE OF 1. FLASH CHROMATOGRAPHY 2. ION CHROMATOGRAPH 3. MICROWAVE MUFFLE FURNACE
NOTICE INVITING TENDERS FOR THE PURCHASE OF 1. FLASH CHROMATOGRAPHY 2. ION CHROMATOGRAPH 3. MICROWAVE MUFFLE FURNACE ANNEXURE-I Sealed offers (rates and terms & conditions) alongwith detailed literature
More informationDatalogging as standard
Datalogging as standard for expanded performance Autofim II and Autofim II GC have a sophisticated datalogging system, as standard, which enables you to keep a permanent data record. The memory is capable
More informationTHE RIGHT CONSUMABLES FOR YOUR GC APPLICATIONS. Clarus 590/690 Gas Chromatography Consumables and Supplies Reference Guide
THE RIGHT CONSUMABLES FOR YOUR GC APPLICATIONS Clarus 590/690 Gas Chromatography Consumables and Supplies Reference Guide INTRODUCTION AND OVERVIEW For laboratories looking for a single gas chromatograph
More informationGC DETECTORS Reduction Gas Detector - RGD. Overview
The SRI Reduction Gas Detector is the most sensitive detector available for hydrogen, carbon monoxide, and other reducing gases. Low ppb detection limits are achievable for hydrogen. Detection limits in
More informationThermo Scientific. TRACE GC Ultra. Gas Chromatograph Maintenance and Troubleshooting Manual. PN , Revision March 2011
Thermo Scientific TRACE GC Ultra Gas Chromatograph Maintenance and Troubleshooting Manual PN 31709180, Revision March 2011 TRACE GC Ultra Maintenance and Troubleshooting Manual March 2011 Edition Original
More informationTubing spares and piping accessories. Gas purification and control 1 Moisture Traps,Carbon traps 2 Gas Purification Panels 3 Gas Control Box
Tubing spares and piping accessories 1 Tubing (SS) 2 Teflon tube 3 PU Tube 4 Moduler Piping Gas purification and control 1 Moisture Traps,Carbon traps 2 Gas Purification Panels 3 Gas Control Box Tubing
More informationAtomic Absorption Spectrophotometer AAS 2320D EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES
Turnkey Laboratories Solutions Atomic Absorption Spectrophotometer AAS 2320D EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES Analytical Technologies Limited An ISO 9001 Certified
More informationSolution. Supply single or multiple GC instruments Continuous Emission and Air monitoring Mud logging application for oil industry
The «Modular Rack Gas Generators» Solution Supply single or multiple GC instruments Continuous Emission and Air monitoring Mud logging application for oil industry With Unique Remote Control Monitoring
More informationHPLC Column Ovens and Temperature Controllers
HPLC Column Ovens and Controllers Improve your separation performance today! Accurate temperature control of your HPLC columns will improve the reproducibility of your results. Operating at increased temperatures
More informationintrinsically safe detector for hydrocarbon gases
portable flame ionisation detector intrinsically safe detector for hydrocarbon gases Intrinsically safe detector for hydrocarbon gases Monitoring gases in confined and potentially explosive situations
More informationAir Server & Multi Channel Samplers (MCS06 & MCS08)
Air Server & Multi Channel Samplers (MCS06 & MCS08) Operators Manual AUGUST 2006 QUI-0004 VERSION 6.1 Ltd. T: +44 (0)1443 230935 F: +44 (0)1443 231531 E: enquiries@markes.com This page left intentionally
More informationGas Chromatograph. Features. Continuous Analysis of Ultra High Purity Argon to ppb levels.
Gas Chromatograph Continuous Analysis of Ultra High Purity Argon to ppb levels Features Following on from the success of the AGC Series 100 Argon GC, AGC Instruments introduces the new NovaCHROM 2000 GC.
More informationChromatography. Research Supplies. 2014/2015 Catalog
Chromatography Research Supplies 2014/2015 Catalog The CRS Commitment Service That Rev lves Around You! Our purpose at CRS is to meet our customer s requirements for quality, service, and value. Quality
More informationAdvanced Autoclave Controller with Recording + 4 Channel Mapping + Pressure Indication with PC Software & Printer Module
Clavex Plus Advanced Autoclave Controller with Recording + 4 Channel Mapping + Pressure Indication with PC Software & Printer Module PC Software Controller with Graphic Display Printer Module Features
More informationHigh Volume Injection up to 5 ml with the Agilent 1200 Infinity Series Online SPE Solution for Highest Sensitivity
High Volume Injection up to ml with the Agilent 00 Infinity Series Online SPE Solution for Highest Sensitivity Technical Overview Author Bettina Schuhn Agilent Technologies, Inc. Waldbronn, Germany Abstract
More information1320 Detectors. 1 of 30. Jun Illustrated Parts Breakdown Agilent 6890 Gas Chromatograph Service Manual
20 Detectors This section contains an illustrated parts breakdown for each of the following 6890 GC detectors and related components. Electron Capture Detector (ECD) Flame Ionization Detector (FID) Nitrogen
More informationDISSOLVED GAS ANALYZER (DGA)
DISSOLVED GAS ANALYZER (DGA) ONE INCH FORWARD After three years of successful operation of inch energy, we are here to contribute the nation growth by making the things indigenous Following the path of
More informationRosemount 1500XA Process Gas Chromatograph
Rosemount 1500XA Process Gas Chromatograph PGC_PDS_1500XA Product Data Sheet Rosemount 1500XA Process Gas Chromatograph Increased pressure to optimize processes is driving an increased demand for accurate
More informationNOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.
www.labocon.com NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation. MICROPLATE READER LMPR-100 SERIES Labocon Microplate Reader LMPR-100
More informationTekmar-DOHRMANN The 3100 Sample Concentrator From ManualLib.com
Tekmar-DOHRMANN The 3100 Sample Concentrator http://www.manuallib.com/file/2660162 From ManualLib.com ManualLib.com collects and classifies the global product instrunction manuals to help users access
More informationAgilent GC Solutions. A Convenient Deans Switch Method for the Analysis of Permanent Gases in Various Matrices by Gas Chromatography CAG
Agilent GC Solutions A Convenient Deans Switch Method for the Analysis of Permanent Gases in Various Matrices by Gas Chromatography CAG Shannon Coleman GC Applications October 7, 0 Advantages to Using
More informationProcess Gas Chromatograph
Process Gas Chromatograph The GC1000 Mark2offers two new process gas chromatographs: the Isothermal Oven type which sets new standards for easy operation and reliable performance; and the Programmed-Temperature
More informationApplication Note. The Agilent 1200 Infinity Series Online SPE Solution for the Highest Sensitivity. Author. Abstract.
Comparison of Online SPE Analysis and Direct Injection of Trace Level Estrogens in Drinking Water with the Agilent 646 and Agilent 649 Triple Quadrupole s The Agilent 1 Infinity Series Online SPE Solution
More informationGas Detection - GD -
s Gas Detection TECHNICAL SPECIFICATIONS Gas Detection DATA SHEE - GD - Continuing development sometimes necessitates specification changes without notice Technical Specifications 2008 GD-00 Gas Measuring
More informationRosemount 1500XA Process Gas Chromatograph
PGC_PDS_1500XA Product Data Sheet Rosemount 1500XA Process Gas Chromatograph Increased pressure to optimize processes is driving an increased demand for accurate and timely composition analysis for use
More informationdetectors UltiMate 3000 Variable Wavelength Detectors
detectors UltiMate 3000 Variable Wavelength Detectors Dionex products are UHPLC compatible by design, establishing the new standard in conventional LC. Integrating hardware, software, and separation chemistry,
More informationWhite paper on the Dielectric Barrier Discharge Detectors. Introduction:
White paper on the Dielectric Barrier Discharge Detectors. Introduction: This paper is a discussion of the dielectric barrier discharge detector. As such, it is intended to provide insight into the operating
More informationSeries 9000 Total Hydrocarbon Analyzer
Series 9000 Total Hydrocarbon Analyzer Analyzer The Baseline Series 9000 is the candidate of choice whenever accurate, reliable total hydrocarbon analysis is required. The Series 9000 analyzer provides
More informationThis SOP and the B.C. Field Sampling Manual are available at: www2.gov.bc.ca.
Monitoring Parameter: Methane and Non-Methane Hydrocarbons Revision No: Draft Revision Date: 09 April, 2018 Title: Standard Operating Procedure for the Non-Continuous Measurement of Ambient Methane and
More informationBIDDER S OFFICE FACILITIES
PT. SULUH ARDHI ENGINEERING PROJECT NO: BIDDER S OFFICE FACILITIES 0 12/02/2016 Issue for Bid LK YW RS Rev. Date Description BY CHK D APP D CONTRACTOR 1. BIDDER S OFFICE FACILITIES 1.1 Building Location
More informationStandard Operating Procedure Gas Chromatograph Mass Spectrometry (GC/MS) - Agilent 7890B GC & 240 Ion Trap MS
Standard Operating Procedure Gas Chromatograph Mass Spectrometry (GC/MS) - Agilent 7890B GC & 240 Ion Trap MS The Agilent 7890B is a state-of-art gas chromatograph (GC) that provides superior performance
More informationIndirect Cryogenic Cold Trap System Instructions
www.sge.com Indirect Cryogenic Cold Trap System Instructions Part Number: 0933451 1.0 INTRODUCTION Congratulations on your purchase of the SGE Indirect Cryogenic Cold Trap System. Please take time to carefully
More informationE²M. Innovation with Integrity. Enhanced Environmental Mass Spectrometer. Safety & Security
E²M Enhanced Environmental Mass Spectrometer Innovation with Integrity Safety & Security Enhanced GC/MS System The E 2 M is the successor to the highly successful and proven GC/MS system EM 640. It represents
More informationAutomatic Isokinetic Sampler ST5
Automatic Isokinetic Sampler ST5 Automatic Isokinetic Sampler ST5 Description The ST5 is the next generation isokinetic sampler, developed to be efficient, rugged, accurate and user friendly. The perfect
More informationAtomic Absorption Spectrometer
Turnkey Laboratories Solutions Atomic Absorption Spectrometer AAS-DB3060 EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES Analytical Technologies Limited An ISO 9001 Certified
More informationPrecision Temperature Control. Pulse Free Pump. Column Oven. Superb Performance Ion Chromatography. Leak Detector. Modular Flexibility
COMPLETE ION CHROMATOGRAPHY COMPLETE ANALYTICAL SYSTEMS Precision Temperature Control The eluent background conductivity changes by about 2% for a 1ºC change in temperature. The cell temperature controlled
More informationTCD-to-FID Series Connection on a 6820 GC, Accessory G4319A
TCD-to-FID Series Connection on a 6820 GC, Accessory G4319A Installation Guide The TCD-to-FID Series Connector connects output flow from a Thermal Conductivity Detector (TCD) to the column inlet of a Flame
More informationportable gas analyser
www..com portable gas analyser The largest of s analysers equipped with electrochemical cells. It can fit even up to 7 EC cells and up to 3 sensors. GA-60 has a large (320*240), graphical LCD with backlighting.
More informationDual Cell Microvolume Thermal Conductivity Detector
Analytical Components Systems & from VICI Valco Instruments Co. Inc. Dual Cell Microvolume Thermal Conductivity Detector Stand-alone unit Optimized for capillary chromatography Thermal stability to ±0.02
More informationTemperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping. Touch Panel PPI
HumiTherm Ultra Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping Mapping Unit Micro PLC Control Unit Touch Panel Touch Operation Panel PPI HumiTherm Ultra GSM Module
More informationISO INTERNATIONAL STANDARD. Essential oils Analysis by gas chromatography on chiral capillary columns General method
INTERNATIONAL STANDARD ISO 22972 First edition 2004-05-15 Essential oils Analysis by gas chromatography on chiral capillary columns General method Huiles essentielles Analyse par chromatographie en phase
More informationLSM MANUAL PRINCIPLES OF LSM
Page 1 1.0 PRINCIPLES OF LSM 1.1. SYSTEM REQUIREMENTS: LSM 3.1 SP1 OR HIGHER (SUBJECT TO CHANGE) GENERAL Local administrator rights for installation Communication: TCP/IP (NetBios active), LAN (recommended:
More informationTitle: Standard Operating Procedure for Measurement of Total Hydrocarbon Using a Flame Ionization Detection
Procedure No: SOP-020 Revision No: 1.0 (January 21, 2011) Page No.: 1 of 7 1. INTRODUCTION AND SCOPE To obtain timely data for the purpose of air quality assessment, air quality trend reporting, and to
More informationTraining Fees 4,000 US$ per participant for Public Training includes Materials/Handouts, tea/coffee breaks, refreshments & Buffet Lunch.
Training Title ADVANCED GC PROCESS Training Duration 5 days Training Venue and Dates Advanced GC Process 5 17 21 February, 2019 $4,000 Dubai, UAE Trainings will be conducted in any of the 5 star hotels.
More informationWide-Bore Heat Exchanger Installation Kit ( )
1090 High Performance Liquid Chromatograph Technical Note Wide-Bore Heat Exchanger Installation Kit (01090-68707) General Information 2 What You Will Need 3 4 Preparing the FPD Flow Cell 5 Preparing the
More informationportable gas analyser
www..com portable gas analyser Professional flue gas analyser that combines high quality of sample conditioning with great measurement accuracy. The device is contained in a compact soft casing. Analyser
More informationRosemount Analytical Solutions. Emerson Offshore Technology Day March 26th 2015 by Rune Damgaard, Account Manager - Measure & Analyze
Rosemount Analytical Solutions Emerson Offshore Technology Day March 26th 2015 by Rune Damgaard, Account Manager - Measure & Analyze Innovation applied to Offshore Applications Well head analysis Process
More informationARES-G2 Rheometer. Site Preparation Guide. Revision A Issued June 2016 Page 1
ARES-G2 Rheometer Site Preparation Guide A Issued June 2016 1 1 A Issued February 2017 Table of Contents Table of Contents... 1 Ideal Setup... 2 System Components... 3 Instrument Measurements... 4 Utility
More informationHFID Heated Total Hydrocarbon Analyzer Module
Product Data Sheet PDS 103-685.A01 October, 2003 NGA 2000 HFID Heated Total Hydrocarbon Analyzer Module Heated analyzer designed to operate from 200 F to 400 F Eliminates loss of hydrocarbons due to condensation
More informationoperations, Environmental & Instrumentation engineering solutions to the Commercial & Industrial segment in the Middle East. ARE
COMPANY PROFILE We are a Customized Engineering Solution Provider in the field of Industrial & Spec Gases WHO operations, Environmental & Instrumentation engineering solutions to the Commercial & Industrial
More informationUniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser
Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser >10h Operation with Li-Ion Battery Pack Smart Autozero without Removal the Probe CO Dilution up to 10% Stores up to 250 Complete Analysis
More informationRef. No. RRSS/CH-18/ RIDF Dated : ii) Submission of e-tender: the tender shall be submitted on line within upto 6.00 pm.
Bidhan Chandra Krishi Viswavidyalaya Regional Research Sub-Station, Chakdaha Uttar Panchpota, P.O. : Chakdaha, Pin-74 222 Dist.: Nadia, West Bengal 905339686(M) E-mail : sukanta.agron@rediffmail.com Dr.
More information4/8/12/16 Channel Temperature Scanner with FREE Data Logging PC Software RS485
Select Option Device Wise Device/Group HumiLog Y-Axis Text Show/Hide Ledgends MIN MAX Scale Y Max 08-05-2015 15:17:59 PV_C PV_RH Color default default Graph Refresh Interval 2 Set Interval PV Low Alarm
More informationLABTRON LAAS - Series Atomic Absorption Spectrophotometer
www.labtron.com LABTRON LAAS - Series Atomic Absorption Spectrophotometer Email: info@labtron.com Atomic Absorption Spectrophotometer LAAS-A10 Labtron LAAS-A10 Atomic Absorption Spectrophotometer comprises
More informationThermo Scientific Dionex UltiMate 3000 Fluorescence Detectors
detectors Thermo Scientific Dionex UltiMate 3000 Fluorescence Detectors Thermo Scientific Dionex products are UHPLC compatible by design, establishing the new standard in conventional LC. Integrating hardware,
More informationWELCOME TO ELLUTIA CHROMATOGRAPHY SOLUTIONS
The 500 Series GC WELCOME TO ELLUTIA CHROMATOGRAPHY SOLUTIONS We are an independent manufacturer of innovative chromatography instruments. Established in 1994 and IRUPHUO\ NQRZQ DV &DPEULGJH 6FLHQWLʳF,QVWUXPHQWV
More informationPRODUCT CONFORMITY CERTIFICATE
PRODUCT CONFORMITY CERTIFICATE This is to certify that the GC 866 PID airtoxic (Model A73022) manufactured by: Chromatotec / airmotec 15, Rue d Artiguelongue Saint -Antoine 33240 Val de Virvée France has
More informationPG 990 Atomic Absorption
PG 990 Atomic Absorption Features Fully Automated Spectrophotometer The flame and graphite furnace is integrated into one instrument. The change over from one technique to another is carried out by simple
More informationBENEFITS. QUATERNARY HPLC SYSTEMS Quaternary and Other Gradients. The Complete Range of HPLC. Convenience of Maintenance. Systems Configuration
TM TM COMPLETE RANGE TM BENEFITS Ultra Fast Scanning Superb Performance Powerful Software Total Flexibility Excellent Reliability Expandable Systems High Pressure Mixing Low Pressure Mixing Video Tutorial
More informationThermo Scientific Rocket Evaporator. Revolutionary solvent evaporation complete laboratory workflow
Thermo Scientific Rocket Evaporator Revolutionary solvent evaporation complete laboratory workflow Sample evaporation with walkaway capability to produce uncompromised results The Thermo Scientific Rocket
More informationPATENTED PATENT PENDING PATENTED PATENTED
2 3 Our services Saniflux Hybrid Diag Nitro Hermetic PATENT PENDING The first A/C system and passenger compartment air purification system combined with a charging station. 2 services in a single station!
More informationSAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)
PART 1 - GENERAL A. RELATED DOCUMENTS SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu) Federal, State, and local requirements as applicable. Attached Permit Attached drawings B. SUMMARY 1. Provide
More informationProcess Gas Chromatographs MAXUM edition II
Overview The is a universal process gas chromatograph for flexible process applications with a wide variety of analytical possibilities. The combines various functional modules with a flexible oven concept
More informationProcess gas chromatography
Siemens AG 2018 /2 Introduction / Introduction Overview is one of the most powerful measuring and analysis methods for process engineering. It is a procedure which is both discrete and extractive. This
More informationSSC Series Standard Accuracy Plastic Silicon Pressure Sensors ±2 % Total Error Band, Digital Output, SMT and DIP, 1 psi to 150 psi
SSC Series Standard Accuracy Plastic Silicon Pressure Sensors ±2 % Total Error Band, Digital Output, SMT and DIP, 1 psi to 150 psi DESCRIPTION The Standard Accuracy Silicon Ceramic (SSC) Series is a piezoresistive
More information300 series HPLC autosamplers
300 series HPLC autosamplers issue 1 Automated HPLC Sampling Manual HPLC sampling can be very difficult and time consuming......hta s range of HPLC autosamplers can perform HPLC sample preparation and
More informationORDERING INFORMATION FEATURES EL-WIN-USB (CONTROL SOFTWARE) Maximum Speci cations Typical Minimum Unit
FEATURES 0-30V d.c. measurement range Logging rates between 1s and 12hr Stores readings Connection via two screw terminals USB interface for set-up and data download User-programmable alarm thresholds
More informationHITACHI CHROMASTER. Clarity Control Module. Code/Rev.: M173/70I Date: 6/23/2018
HITACHI CHROMASTER Clarity Control Module ENG Code/Rev.: M173/70I Date: 6/23/2018 Phone: +420 251 013 400 DataApex Ltd. Fax: +420 251 013 401 Petrzilkova 2583/13 clarity@dataapex.com 158 00 Prague 5 www.dataapex.com
More information