P0WER SUPPLY & OUT AUX PWR INPUTS IN O O O O O O RELAYS 1-4 RELAYS 5-8

Size: px
Start display at page:

Download "P0WER SUPPLY & OUT AUX PWR INPUTS IN O O O O O O RELAYS 1-4 RELAYS 5-8"

Transcription

1 Revised! see Protective Earthing Addendum P0WER SUPPLY & OUT AUX PWR INPUTS IN O O Relays: O O O O RELAY CONTACTS RELAY CONTACTS RELAYS 1-4 RELAYS 5-8 An 8 way Clocked Relay Controller provides eight single pole Relays with connection terminals to the Common (C), Normally Open (NO), and Normally Closed (NC) contacts. The Relay contacts are rated at 1 0 to 30V DC; reducing to 48V DC. Relay Controllers can be connected together to provide up to 16 relays when connected to a Data Gathering Panel, 64 relays in a Single Lift Controller, or 256 relays when connected to the Challenger Alarm Panel. Mounting: ( See table on page 3 ) TS0816: TS0841 Relay Cards must be mounted in a separate enclosure and are connected with the cable supplied. All 8-32 I/P DGPs: Up to two TS0841 can mount on existing standoffs in all 8-32 Input Data Gathering Panels, depending on what other modules are fitted. TS0015: TS0304: If connected to Version 6 Challenger Alarm Panels, a separate enclosure is required. Separate Enclosure. V6 DGP Box 360 x 260 x 75mm with mounting for 1 Size "A" PCB, and 4 Size "B" PCBs or 2 Size "Double B" PCBs. Note: The TS0841 is a Size "Double B" PCB. Dimensions ( PCB Card ): Size Double B PCB: 176 x 52 mm Current consumption: The Clocked Relay controller requires 50mA standby current and 250mA with all 8 relays active. Version 8. 8 Way Clocked Relay Card - TS0841: Issue I, Revision I: August

2 Wiring: Interconnection between the Relay Controller and the different Challenger equipment is detailed below. Version 8. Challenger Alarm Panel. TS0816 OR Version 8. 8 Input Data Gathering Panel. TS0820, TS0822, TS0823, TS0824 Cable: LEV P ( Supplied ) V8 Chall Panel J14 OR V8. 8 I/P DGP J Volts 1 2 Data 2 4 Latch 4 5 Clk Volts 10 Version 6 Challenger Alarm Panel. TS0015 OR 8 Input Data Gathering Panel. TS0020, TS0022, TS0023, TS0024 Cable: LEV6-CLK ( Ordered separately ) V6 Chall Panel J8 OR 8 I/P DGP J6 1 Data 7 2 Latch 6 3 Clk Volts Volts 1 Version 5 Challenger Alarm Panel. TS0010 to TS0014, TS05?? Cable: LEV5-CLK ( Ordered separately ) V5 Chall Panel J8 1 Data 3 2 Latch 4 3 Clk Volts Volts 1 16 Input Data Gathering Panel or Access Controller. TS0016, TS0017, TS0067, TS0069 Cable: LEDGP16-CLK ( Ordered separately ) 16 I/P DGP J8 1 Data 6 2 Latch 7 3 Clk Volts Volts 1 Interconnection between two TS0841 Relay Controllers. Cable: LEV P ( Supplied ) Relay Controller Out Volts 1 2 Data 2 4 Latch 4 5 Clk Volts 10 2 TS0841IN.P65: Issue I, Revision I: August 1994

3 Maximum 8 Way Relay Cards per Challenger product: Maximum Cards. Maximum Usable Relays. Alarm Panels: (All versions) DGPs: (All versions) 2 16 Lift Controller: (TS0069) 8 64 Note: Clocked Relay Cards and 4 Way Relay Cards cannot be used together on the same product. Installation Summary: TS0841 CAN CONNECT TO CABLE INSTALLATION TS0816 V8 Alarm Panel. TS0820/TS0822 V8 DGPs. TS0841/TS0842 interconnection. TS0015 Alarm Panel (V6 / V7). TS0020/TS I/P DGP. TS I/P DGP. TS0067 Door Controller. V5 Challenger Alarm Panels. TS0041/TS0042 Relay / Open Collector Card. Cable supplied Cable supplied Cable supplied LEV6-CLK LEV6-CLK LEDGP16-CLK LEDGP16-CLK LEV5-CLK LECLK-CLK Up to 2 TS0841s can be fitted in TS082? enclosure depending on what other cards fitted. Up to 2 TS0841s can be fitted in TS002? enclosure depending on what other cards fitted. Up to 2 TS0841s can be fitted in V5 enclosure, but extra standoffs required. Cable for interconnecting TS004? Clocked Relay/Open Collector Cards. Power Supply Connections: PWR +12 0V AUX + - Alternative +12 Volt and 0 Volt Power supply connection. This terminal is used when it is necessary to make the Supply connection using heavier guage cable (e.g. figure 8), or from a separate power supply, in order to minimise Voltage drop over longer distances or reduce current drain on the Panel or DGP. If using this power supply connection: - V8 Panel; Remove the "+12V" link near J14. - Other equipment; Ensure that the +12V wire in the "CLK" cable is NOT connected. The AUX + & - terminals are completely separate from the PWR connections and provide the facility to link the Common contacts of the 8 Relays to a positive or negative voltage source (48V DC maximum). Links 1 to 8 allow each of the Common contacts to be linked to Aux + or Aux - as required. Version 8. 8 Way Clocked Relay Card - TS0841: Issue I, Revision I: August

4 Enabling and Programming: Program Relay Assignments. Map relays to Event numbers and/or timezones as required. Relay function can also be inverted or programmed to be active or inactive during thetimezone. See: Challenger Programming Guide for more information. (Installer Menu Option 16) Version 6, 7 & 8 Challenger Alarm Panels. TS0015 & TS0816 Relay Controllers. Enter the number of 8 way Relay Controllers connected to the Challenger Alarm Panel Input Data Gathering Panel. TS0020 to TS0024 & TS0820 to TS0824 Switch DIP switch 6 on Data Gathering Panel to "ON". This enables up to two 8 way Relay Cards. Version 5.9 Challenger Alarm Panel. TS0010 to TS0014, TS05?? Remove Links RL5, RL6 & RL7 on the Alarm Panel PCB. Relays 5, 6, & 7 on the Alarm Panel become inoperative. Installer Menu Option 7 - Program System Options. Output Controllers. Enter the number of 8 way Relay Card Output Controllers connected to the Challenger Alarm Panel. On earlier Version 5 Alarm Panels the Output Controllers option is not enabled by programming. In this case it is necessary to switch DIP switch 6 on the Alarm Panel to "ON". 16 Input Data Gathering Panel. TS0016, TS0017. Switch DIP switch 6 on Data Gathering Panel to "ON". This enables up to two 8 way Relay Cards. 16 Input Access Controller Data Gathering Panel. TS0067, TS0069 Output Controllers. Enter the number of 8 way Relay Controllers connected to the Access Controller. Connection Diagram: PANEL OR DGP TS0841 TS0841 (See tables on p2) CLKOUT IN IN OUT OUT TO OTHER TS0841 RELAY CARDS IF CONNECTED TO CHALLENGER PANEL 4 TS0841IN.P65: Issue I, Revision I: August 1994

5 N4131 Please note, this product conforms to the standards set by Standards Australia on behalf of the Australian Telecommunications Authority (AUSTEL) and the Spectrum Management Agency (SMA). WARNING: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. The Challenger is designed and manufactured by: Interlogix Australia Pty Ltd 646 Whitehorse Rd MITCHAM VIC 3132 A.B.N PH: FX: C Interlogix Australia 2001 Version 8. 8 Way Clocked Relay Card - TS0841: Issue I, Revision I: August

6

Challenger V8 4-Way Relay Card TS0840 TECOM. Installation Guide. Revised! see Protective Earthing Addendum O O O O. Relays: Dimensions ( PCB Card )

Challenger V8 4-Way Relay Card TS0840 TECOM. Installation Guide. Revised! see Protective Earthing Addendum O O O O. Relays: Dimensions ( PCB Card ) Revised! see Protective Earthing Addendum Installation Guide J2 O O J1 4 IN 3 RELAY OUTPUTS EXPANSION 2 J3 1 O O Relays: A 4 way Relay Module provides four 1 Amp single pole Relays with connection terminals

More information

Challenger Version 8 Programming Relays.

Challenger Version 8 Programming Relays. Challenger Version 8 This document provides details of the programming requirements for activating relays on the Challenger system. The following are some of the applications that Challenger Relays may

More information

IEI NETWORK INTERFACE MODEL TS2040

IEI NETWORK INTERFACE MODEL TS2040 IEI NETWORK INTERFACE MODEL TS2040 INSTALLATION GUIDE Revised! see Protective Earthing Addendum NOTE: This equipment must only be installed and serviced by professional qualified personnel. O O + - D+

More information

Each reader connected to the Challenger LAN system is programmed as an Arming Station.

Each reader connected to the Challenger LAN system is programmed as an Arming Station. Challenger Version 8 Readers. This document provides details of the programming requirements for adding readers to a Version 8 Challenger System for use in Alarm Control Access Control functions. Each

More information

Power Supply / Battery Charger Units, incorporating load switching relays for Smoke Dispersal, Bell Booster or other uses

Power Supply / Battery Charger Units, incorporating load switching relays for Smoke Dispersal, Bell Booster or other uses BCU Power Supplies Power Supply / Battery Charger Units, incorporating load switching relays for Smoke Dispersal, Bell Booster or other uses Installation, Commissioning and Operating Manual BCU RANGE OF

More information

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009 Sigma K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels Operation and Maintenance Manual Man-1048 Issue 05 October 2009 CONTENTS Contents... Page Safety & Installation...2 Installation - continued...3

More information

Power Wave Zone Alarm Panel V8.5. Installation Manual

Power Wave Zone Alarm Panel V8.5. Installation Manual Power Wave - 8 8 Zone Alarm Panel V8.5 Installation Manual 7 December 2001 Crow (Aust) Electronic Engineering Pty Ltd Corporate Head Office: 429 Nepean Hwy, Brighton East, Vic., 3187 Australia Phone: +61

More information

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel INSTALLATION, OPERATION AND MAINTENANCE MANUAL Version: CN-PM-1000.VER1.1-12/2012 EN54 INFORMATION In accordance with EN 54-2 clause 13.7, the maximum

More information

Installation, Operating and Maintenance Manual

Installation, Operating and Maintenance Manual STATUS ZONES CONTROLS FIRE FAULT DISABLED FIRE 1 2 3 4 5 6 7 8 TEST FAULT DISABLED 1 5 BUZZER SILENCE RESET 1 2 TEST 2 6 LAMP TEST 3 SUPPLY 3 7 SYSTEM FAULT 4 8 SOUNDERS ACTIVATE/ SILENCE 4 FAULTS INSTRUCTIONS

More information

Power Wave. 8 Zone Control Communicator. Crow Electronic Engineering P/L. Ver:8.54. Installation & Programming Guide.

Power Wave. 8 Zone Control Communicator. Crow Electronic Engineering P/L. Ver:8.54. Installation & Programming Guide. Power Wave 8 8 Zone Control Communicator Crow Electronic Engineering P/L Ver:8.54 Installation & Programming Guide 8 November 2000 Crow ( Aust ) Electronic Engineering Pty Ltd Corporate Head Office: 429

More information

General Routing Interface

General Routing Interface General Routing Interface Features The General Routing Interface Card is an optional module to provide Fire and Fault Routing Outputs compliant with BSEN54-2: 1998 Clauses 7.9 and 8.9 and BS5839-1: 2002.

More information

MTRA-FSP Level Control Relay. Installation & Operation Manual

MTRA-FSP Level Control Relay. Installation & Operation Manual MTRA-FSP Level Control Relay Installation & Operation Manual This Manual is the support documentation for the installation, commissioning and operation of the MTRA-FSP Level Control Relay. Document Revision

More information

MEDI-MINDER USER MANUAL

MEDI-MINDER USER MANUAL MEDI-MINDER USER MANUAL TABLE OF CONTENTS TABLE OF CONTENTS... 1 INTRODUCTION... 1 SMARTLINK FEATURES... 2 USING SMARTLINK... 3 SPECIAL FUNCTIONS... 5 DISPLAYS AND WARNINGS... 6 SPECIFICATIONS... 7 INTRODUCTION

More information

Fratech Multipath-IP

Fratech Multipath-IP Rev 2.0 (May 2013) Installer Manual 1 Current Part Numbers: Fratech Multipath-IP E-Link STU PCB & Accessory Kit only In Metal Enclosure with Power Supply 998325-PK 998325-XS Installer Manual This document

More information

The EN54 Part 2 & 4 Fire System

The EN54 Part 2 & 4 Fire System Scope of work: To design, supply, install and commission an Analogue Addressable Fire Alarm Control System in accordance with the details specified herein and in accordance with supplied drawings The EN54

More information

FEC400 Series. Installation Manual

FEC400 Series. Installation Manual FEC400 Series Conventional microprocessor controlled fire detection and alarm panels with extinguishing control Installation Manual Version 2.3 / August 2004 Aritech is a GE Interlogix brand. http://www.geindustrial.com/ge-interlogix/emea

More information

TECOM SYSTEMS NETWORK MASTER

TECOM SYSTEMS NETWORK MASTER TECOM SYSTEMS NETWORK MASTER The Tecom Network Master is a cost effective, Dialler Receiver and Direct Line Network Master combined in a single modular unit. HARDWARE The unit consists of a 3RU, 19 inch

More information

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module FIRE ALARM CONTROL EQUIPMENT Addendum October 2006 Instructions for new style EN54-4 Power supply unit module MXLK-05 Issue 2.0 June 2007 INSTALLATION Safety Suppliers of articles for use at work are required

More information

(Updated Defaults) (Covers Ver: 8.64 and above)

(Updated Defaults) (Covers Ver: 8.64 and above) Power Wave - 8 8 Zone Alarm Panel V8.71 / 8.72 (Updated Defaults) (Covers Ver: 8.64 and above) Installation Manual 10-December-2003 Crow (Aust) Electronic Engineering Pty Ltd Corporate Head Office: 429

More information

LED Driver Module. These instructions contain procedures to follow in order to avoid personal injury and damage to equipment.

LED Driver Module. These instructions contain procedures to follow in order to avoid personal injury and damage to equipment. LED Driver Module Installation Guide 1.0 Notice These instructions are for installing Radionics LED Driver Module in a fire alarm system controlled by Radionics D8024 or D10024 Fire Alarm Control Panels

More information

PERTRONIC INDUSTRIES LTD F4-RMAX Installation Note

PERTRONIC INDUSTRIES LTD F4-RMAX Installation Note Product Overview: The Pertronic F4 Remote LED Mimic / Aux Relay Module F4-RMAX is an optional extra for the Pertronic F4 conventional 4-zone fire alarm panel. This board enables the fire alarm panel to

More information

EXTINGUISHING AGENT RELEASE MODULE

EXTINGUISHING AGENT RELEASE MODULE EXTINGUISHING AGENT RELEASE MODULE Operation, Installation & Programming Manual Revision 3.00 Distributors For: 18-20 Brookhollow Ave telephone 02 8850 2888 www.firesense.com.au Baulkham Hills NSW 2153

More information

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels Installation and user manual for the FX range of fire panels 1, 2, 4 and 8 zone panels Contents Panel installation 3 Panel connections 3 Wiring connection drawings 4 Panel facilities 6 Installation check

More information

Beacon 800 Gas Monitor Operator s Manual

Beacon 800 Gas Monitor Operator s Manual Beacon 800 Gas Monitor Operator s Manual Part Number: 71-0037RK Revision: F Released: 4/18/17 www.rkiinstruments.com Product Warranty RKI Instruments, Inc. warrants gas alarm equipment sold by us to be

More information

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE General Description This guide provides a summary for installing and configuring the Centaur TM Cube Slave Alarm Signalling Equipment

More information

KT-100 Door Controller

KT-100 Door Controller WARNING: This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be carefully

More information

GE Security. ATS1250/ door DGP / 4-lift DGP. Installation guide

GE Security. ATS1250/ door DGP / 4-lift DGP. Installation guide GE Security 4-door DGP / 4-lift DGP 1057150 Version 2.4, 10/2006 2 Copyright Disclaimer Trademarks and patents Software license agreement Intended use European directives Regulatory Copyright 2007, GE

More information

Planning Elevator Relay Groups Programming Millenium for Windows Software

Planning Elevator Relay Groups Programming Millenium for Windows Software Installation Booklet: Elevator Control Unit (ECU) Introduction The Elevator Control Unit (ECU) is an option in the Millenium for Windows systems. Once you add an elevator in the software, each elevator

More information

Challenger10 Users Manual

Challenger10 Users Manual Challenger10 Users Manual P/N MAUSER-TS1016 REV 01 ISS 18FEB13 Copyright Trademarks and patents Manufacturer Agency compliance Contact information 2013 UTC Fire & Security. All rights reserved. The Challenger

More information

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL Document No...G108WO1.DOC Serial No... Issue Date...17 th SEPTEMBER 1999 Software Version...1.4 APPROVED TO: NZS 4512:1997 AS/NZS 3548:1992 Fire Alarm

More information

INSTALLATION AND PROGRAMMING MANUAL

INSTALLATION AND PROGRAMMING MANUAL INSTALLATION AND PROGRAMMING MANUAL Contents Section 0. Section 1. Section 2. Section 3. Section 4. Section 5. Section 6. Section 7. Section 8. Section 9. Section 10. Section 11. Section 12. Section 13.

More information

16 ( Ver: Installation & Programming Guide. Power Wave 16 Zone Control Communicator. Crow Electronic Engineering (Australia) Pty Ltd

16 ( Ver: Installation & Programming Guide. Power Wave 16 Zone Control Communicator. Crow Electronic Engineering (Australia) Pty Ltd Power Wave 16 Zone Control Communicator 16 ( Ver: 6.28 ) This Manual is Preliminary. Please refer to the Condensed manual for additional information Crow Electronic Engineering (Australia) Pty Ltd Installation

More information

HRX Technical Manual. Version 1.2

HRX Technical Manual. Version 1.2 HRX 5000 Technical Manual Version 1.2 Contents: Specification...2 Connectors...5 RS-485 Network Connectors (J6 and J7)...5 RS-232 to Printer (J19)...6 RS-232 to PC (J8)...7 TCP/IP...8 Power (J21)...9 Fire

More information

Networked Access Control Panel. Installation Guide

Networked Access Control Panel. Installation Guide XP2M Networked Access Control Panel V1.0X Installation Guide X P 2 M A C C E S S C O N T R O L S Y S T E M Installation Guide Document Ref: PLAN XP2M Installation Guide V4(G)2010 Access Control Services

More information

IDP-Zone-6 Six Zone Interface Module

IDP-Zone-6 Six Zone Interface Module INSTALLATION AND MAINTENANCE INSTRUCTIONS IDP-Zone-6 Six Zone Interface Module BEFORE INSTALLING If the modules will be installed in an existing operational system, inform the operator and local authority

More information

C-Bus Bus Coupler with Scenes 5102BCLEDL 5104BCL

C-Bus Bus Coupler with Scenes 5102BCLEDL 5104BCL C-Bus Bus Coupler with Scenes 5102BCLEDL 5104BCL Clipsal and C-Bus are registered trademarks of Clipsal Australia Pty Ltd ABN 27 007 873 529. Copyright Clipsal Australia Pty Ltd 2008. All rights reserved.

More information

Model 17A00 Expansion Enclosure

Model 17A00 Expansion Enclosure HOME AUTOMATION, INC. Model 17A00 Expansion Enclosure Installation Manual Document Number 17I00-1 Rev A March, 2002 Home Automation, Inc. Model 17A00 Expansion Enclosure Installation Manual Document Number

More information

MEDI-MINDER USER MANUAL

MEDI-MINDER USER MANUAL MEDI-MINDER USER MANUAL TABLE OF CONTENTS TABLE OF CONTENTS...1 INTRODUCTION...1 MEDI-MINDER FEATURES...2 PENDANTS & DETECTORS... 3 USING MEDI-MINDER... 3 DISPLAYS AND WARNINGS...5 CELLULAR SIGNAL QUALITY...

More information

Excel-EN Conventional Fire Control Panel

Excel-EN Conventional Fire Control Panel Available as 2, 4, 6, 8,10 or 12 zones Approved to EN54-2 & 4 Modular expansion zone cards Programmable relays and outputs Optional additional sounder circuits Optional additional programmable outputs

More information

C-Bus 2 Channel Bus Coupler with Remote LED Facility Installation Instructions

C-Bus 2 Channel Bus Coupler with Remote LED Facility Installation Instructions C-Bus 2 Channel Bus Coupler with Remote LED Facility Installation Instructions 5102BCLEDL REGISTERED PATENT Table of Contents Section...Page 1.0 Product Range... 3 2.0 Description... 3 3.0 Capabilities...

More information

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

La Marche Manufacturing Company   Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual La Marche Manufacturing Company www.lamarchemfg.com Option 16 Series Digital Combined Accessory Package Installation and Operation Manual This manual is subject to change without notice. You may obtain

More information

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS QUICK USER GUIDE FOR, 2 & 4 ZONE PANELS INDICATORS COLOUR INDICATION MON FAULT Yellow On when a fault condition has occurred, or if no other fault Led is on, this indicates 24v auxiliary fuse failure.

More information

Eclipse MC240. Double & Single Gate Controller with Eclipse Operating System (EOS) 3rd Edition. MC240 for Double and Single Gates.

Eclipse MC240. Double & Single Gate Controller with Eclipse Operating System (EOS) 3rd Edition. MC240 for Double and Single Gates. 3rd Edition Double & Single Gate Controller with Eclipse Operating System (EOS) Eclipse MC240 www.elsema.com MC240 for Double and Single Gates Setup and Technical Information Includes latest Intelligent

More information

10yr O2NE & Safe-Ox. User Manual

10yr O2NE & Safe-Ox. User Manual Analox Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK T: +44 (0)1642 711400 F: +44 (0)1642 713900 W: www.analox.net E: info@analox.net This support line is closed on UK public

More information

Operation and Installation Guide. Fire Alarm Control Panel

Operation and Installation Guide. Fire Alarm Control Panel Operation and Installation Guide Fire Alarm Control Panel 2001 Radionics Page 2 P/N: 36958D Contents Contents 1.0 Notices... 5 1.1 FCC Compliance Notice... 5 1.2 Notice... 5 1.3 Installation Guidelines

More information

WM3000 WIRELESS MODULES

WM3000 WIRELESS MODULES WM3000 WIRELESS MODULES $$:05 $$:07 INSTALLATION INSTRUCTIONS Table of Contents Installation... 3 Mounting Instructions & Connections... 3 Setting the Dip Switches... 4 Setting the Recognition Time...

More information

AS DIGITAL FIRE PUMP CONTROLLER

AS DIGITAL FIRE PUMP CONTROLLER AS 2941-2013 DIGITAL FIRE PUMP CONTROLLER COMPLIANT WITH AS2941-2013 CLAUSES 9.4.1 9.4.22 OPERATION INSTRUCTIONS New South Wales Unit 2/1040 Canley Vale Road Wetherill Park NSW 2164 Ph: +61 2 9757 5800

More information

Application, Installation, Operation & Maintenance Manual

Application, Installation, Operation & Maintenance Manual APPROVED BY:JBJ PRESCIENT III FIRE ALARM & GAS EXTINGUISHING CONTROL PANEL Application, Installation, Operation & Maintenance Manual PAGE 1 of 43 CONTENTS 1. INTRODUCTION... 3 2. GENERAL DESCRIPTION...

More information

Interface Modules for SENTRI

Interface Modules for SENTRI EQUIPMENT INTERFACED Data and Installation Interface s for SENTRI Low voltage (LV) / SEN-INT-INPUT 1- Interface (low voltage) SEN-INT-OUTPUT 1- & 1- Interface (low voltage) SEN-INT-4IO # 4- / Interface

More information

MD12-2 Vehicle Loop Detector

MD12-2 Vehicle Loop Detector MD12-2 Vehicle Loop Detector Features Supply 12VDC Adjustable sensitivity (8 levels via dip switch) 2 x Relay outputs (each can be configured individually) Power up and loop activation LED indicator. Industry

More information

1 INCA INCA MODEL FPC FIRE PUMP CONTROL PANEL. (Star Delta/D.O.L) USER MANUAL Inca Reference FPC Revision 1.0

1 INCA INCA MODEL FPC FIRE PUMP CONTROL PANEL. (Star Delta/D.O.L) USER MANUAL Inca Reference FPC Revision 1.0 1 INCA CONTROL PTY LTD Phone: (02) 96753815 UNIT 14/62 OWEN ST Fax: (02) 96751381 GLENDENNING NSW 2761 A.B.N 54 131 353 636 Design & Manufacture of: Custom-built switchboards Electronic control equipment

More information

SMARTWALK DEMENTIA WANDERING SYSTEM

SMARTWALK DEMENTIA WANDERING SYSTEM A division of NESS CORPORATION PTY LTD SMARTWALK DEMENTIA WANDERING SYSTEM SWD Door Responder SWD Resonator SWD-PET (Sold Separately) SWD-PET-BAND (Sold Separately) INSTALLATION MANUAL 1. CONTENTS 1. CONTENTS...1

More information

MODEL KP-200 VANDAL RESISTANT & WEATHERPROOF FLUSH MOUNT DIGITAL KEYPAD DESIGNED FOR ACCESS CONTROL APPLICATIONS

MODEL KP-200 VANDAL RESISTANT & WEATHERPROOF FLUSH MOUNT DIGITAL KEYPAD DESIGNED FOR ACCESS CONTROL APPLICATIONS MODEL KP-200 VANDAL RESISTANT & WEATHERPROOF FLUSH MOUNT DIGITAL KEYPAD DESIGNED FOR ACCESS CONTROL APPLICATIONS OPERATES ON 12 OR 24 VOLTS AC/DC, AUTO VOLTAGE SENSING FULLY PROGRAMMABLE FROM THE KEYPAD

More information

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES POWER SUPPLY AND BATTERY CHARGER AC AND DC STATUS INDICATORS ENOUGH POWER TO SUPPORT UP TO 3 MAGLOCKS OR ELECTRIC STRIKES PLUS REQUIRED

More information

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08 Beacon 200 Gas Monitor Operator s Manual Part Number: 71-2102RK Released: 6/6/08 Table of Contents Chapter 1: Introduction.................................................3 Overview.............................................................3

More information

Pakton Technologies Pty Ltd ABN Ferrier Road, Narangba Qld 4504

Pakton Technologies Pty Ltd ABN Ferrier Road, Narangba Qld 4504 Remote Monitor PTE0700 SECURITY ELECTRONICS User Manual PTE0700 V2 Series Remote Monitor Pakton Technologies Pty Ltd ABN 66 405 694 842 16 Ferrier Road, Narangba Qld 4504 PO Box 408, Narangba QLD 4504

More information

AL800ULADA. NAC Power Extender. Installation Guide

AL800ULADA. NAC Power Extender. Installation Guide AL800ULADA NAC Power Extender Installation Guide Rev. 122000 AL800ULADA - NAC Power Extender Overview: The Altronix AL800ULADA is an extremely cost effective 8 amp voltage regulated remote power supply/battery

More information

LUX Hardwired - Installation Notes

LUX Hardwired - Installation Notes Ness LUX wired PIR with Nightlight Quad element pyro sensor 15m x 15m wide angle coverage Look down Creep Zone Selectable Standard and Pet Aware modes Adjustable sensor mask for No Creep and Pet modes

More information

MD12-1 Vehicle Loop Detector

MD12-1 Vehicle Loop Detector MD12-1 Vehicle Loop Detector Features Supply 12VDC Adjustable sensitivity (16 levels via a trimpot) 2 x Relay outputs (each can be configured individually) Power up and loop activation LED indicator. Industry

More information

20 Light Remote Annunciator

20 Light Remote Annunciator Light Remote Annunciator Owner s Manual Surface Mount Flush Mount 94-95- Standard Annunciator 94-, 94-95-, 95-4- 4- Annunciator w/remote Relay Panel 4-, 4-4-, 4-49-, 49-49-, 49- Time Multiplexed Annunciator

More information

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum. September 29, 1997 Firecycle III 433 a 1. PRODUCT NAME VIKING Model E-1 Manufactured 1997 Present 2. MANUFACTURED FOR THE VIKING CORPORATION 210 N Industrial Park Road Hastings, Michigan 49058, U.S.A.

More information

ADEMCO 4208SNF V-Plex Universal Class A Module INSTALLATION AND SETUP GUIDE

ADEMCO 4208SNF V-Plex Universal Class A Module INSTALLATION AND SETUP GUIDE K3179V2 2/11 Rev. A ADEMCO 4208SNF V-Plex Universal Class A Module INSTALLATION AND SETUP GUIDE FEATURES The ADEMCO 4208SNF Universal Class A Module can be used in either of two different applications.

More information

Medi-Minder Guardian USER MANUAL

Medi-Minder Guardian USER MANUAL Medi-Minder Guardian USER MANUAL 1 Table of Contents TABLE OF CONTENTS...2 INTRODUCTION...2 MEDI-MINDER GUARDIAN...3 PENDANTS AND DETECTORS...4 USING MEDI-MINDER GUARDIAN... 4 DISPLAYS AND WARNINGS...6

More information

OPERATION AND INSTALLATION MANUAL

OPERATION AND INSTALLATION MANUAL EX+Plus 2 ZONE, 1AREA EXTINGUISHANT CONTROL PANEL OPERATION AND INSTALLATION MANUAL INTRODUCTION The Premier EX Plus is a 2 zone, single area panel for controlling the release of extinguishing gases in

More information

Gas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 2800PPM. Merlin CO2 Monitor 2800ppm. American Gas Safety LLC 1

Gas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 2800PPM. Merlin CO2 Monitor 2800ppm. American Gas Safety LLC 1 Gas Safety Products Merlin CO2 Monitor 2800PPM Installation, operating and maintenance 05/10/2016 American Gas Safety LLC 1 Table of contents 1 General information... 3 2 Installation... 3 2.1 Mounting

More information

LDM Series Lamp Driver Modules For Graphic Annunciation and Control

LDM Series Lamp Driver Modules For Graphic Annunciation and Control 12 Clintonville Road Northford, CT 06472 (203) 484-7161 FAX: (203) 484-7118 LDM Series Lamp Driver Modules For Graphic Annunciation and Control Used with the System 500, System 5000, AM2020/AFP1010 and

More information

DigiAir QUICK GUIDE & INSTRUCTION MANUAL

DigiAir QUICK GUIDE & INSTRUCTION MANUAL DigiAir QUICK GUIDE & INSTRUCTION MANUAL The most trusted brand in Alarm Signalling www.csldual.com @CSLDualCom CSL DualCom Limited Figure 1 - DigiAir Yellow Comms LED Red Fault LED Yellow Service LED

More information

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual Revision 1.03 8 November 2013 JVA Technologies Ethernet General Purpose IO Technical Manual www.jva-fence.com.au Table of Contents INTRODUCTION...3 Scope and Purpose...3 Glossary...3 SPECIFICATIONS...4

More information

OPERATION / INSTALLATION

OPERATION / INSTALLATION OPERATION / INSTALLATION & PROGRAMMING MANUAL AFP-2800 LCD-80 Fire Alarm Panel Revision 1.01 November 16, 2004 NSW (Head Office) 7 Columbia Court Norwest Business Park Baulkham Hills NSW 2153 Ph: (02)

More information

SC-6 Six Supervised Control Module

SC-6 Six Supervised Control Module INSTALLATION AND MAINTENANCE INSTRUCTIONS SC-6 Six Supervised Control Module SPECIFICATIONS Normal Operating Voltage: Stand-By Current: Alarm Current: Temperature Range: Humidity: Dimensions: Accessories:

More information

The Remote alarm Panel, TYPE RAPv2

The Remote alarm Panel, TYPE RAPv2 1. Introduction The Remote alarm Panel, TYPE RAPv2 The microprocessor based remote monitor from Metron Eledyne is the latest version of a whole line of successful products, marketed previously under the

More information

DYCU-3 AEROSOL FIRE EXTINGUISHER CONTROL UNIT OPERATION MANUAL

DYCU-3 AEROSOL FIRE EXTINGUISHER CONTROL UNIT OPERATION MANUAL DYCU-3 AEROSOL FIRE EXTINGUISHER CONTROL UNIT OPERATION MANUAL DOC: GLT.MAN-136 1 INDEX INTRODUCTION 3 CONNECTIONS 4 OPERATION 5 LINKING 6 TECHNICAL INFO 7 DOC: GLT.MAN-136 2 INTRODUCTION The Dynameco

More information

4100S. The operation and functions described in this manual are available from Software Version 4100S onwards.

4100S. The operation and functions described in this manual are available from Software Version 4100S onwards. 4100S The operation and functions described in this manual are available from Software Version 4100S-023-013 onwards. Specifications: Item Specification Details Enclosure Steel IP30 Dimensions H x W x

More information

Data Sheet 220 LEVEL MONITOR. Supplied by. .com. Call us on +44 (0)

Data Sheet 220 LEVEL MONITOR. Supplied by. .com. Call us on +44 (0) Data Sheet 220 LEVEL MONITOR Supplied by.com Call us on +44 (0)118 916 9420 Email info@247able.com Model 220 Powered by 4-20mA loop Non-linear tank correction Four level alarms Level bar graph display

More information

RS Pro Infrared Temperature Sensor

RS Pro Infrared Temperature Sensor Instruction Manual RS Pro Infrared Temperature Sensor Stock Number: 161-8103 Introduction The RS Pro Infrared Temperature Sensor is a device for measuring the temperature of the surface of a solid or liquid

More information

Installation Guide for models:

Installation Guide for models: 140 58th St. Brooklyn, NY Access Power Controllers with Power Supplies Installation Guide for models: Maximal11F - Power Supply 1: 12VDC @ 3.3 amp or 24VDC @ 3.6 amp. - Power Supply 2: 12VDC @ 3.3 amp

More information

Challenger Series Users Manual

Challenger Series Users Manual Challenger Series Users Manual P/N MAUSER-TS1016 05 20AUG15 Copyright Trademarks and patents Manufacturer 2015 UTC Fire & Security Australia Pty Ltd. All rights reserved. The Challenger name and logo are

More information

A36D/TPSD Modbus TCP SCADA INTERFACE INSTRUCTIONS

A36D/TPSD Modbus TCP SCADA INTERFACE INSTRUCTIONS SCADA INTERFACE INSTRUCTIONS - OPTION 21Q - FOR A36D/TPSD SYSTEMS with 500 and 550 option. A36D/TPSD Modbus TCP SCADA INTERFACE OPTION 21Q INSTRUCTIONS This manual is valid for A36D/TPSD Chargers equipped

More information

Booster Power Supply Manual

Booster Power Supply Manual Supply Manual DEVELOPED BY COPYRIGHT NOTICE General Signal Building Systems Corporation 6411 Parkland Drive Sarasota, FL 34243 (941) 739-4300 Copyright 1999 General Signal Building Systems Corporation

More information

IRIS Touch 400 & 600 Range Installation Manual. Honeywell Galaxy Range. Version 2.0

IRIS Touch 400 & 600 Range Installation Manual. Honeywell Galaxy Range. Version 2.0 IRIS Touch 400 & 600 Range Installation Manual Honeywell Galaxy Range Version 2.0 Table of Contents 1 System Overview... 4 2 IRIS Touch 440 & 640 PCB Layout... 5 3 Connection & Configuration for Honeywell

More information

La Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual

La Marche Manufacturing Company   Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual La Marche Manufacturing Company www.lamarchemfg.com Option 46 Series Digital Combined Accessory Package Installation and Operation Manual This manual is subject to change without notice. You may obtain

More information

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev AL802ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 031703 Overview: The Altronix AL802ULADA is an extremely cost effective 8 amp voltage regulated

More information

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

STATUS ALARM ALARM HISTORY POWER HISTORY RESET Instruction Manual Model 1582-152 RF Protection Switch November 2009, Rev B. CH1 AUTO CH2 SWITCH 1 2 1 2 STATUS 1 2 MODEL 1582 SWITCH CROSS TECHNOLOGIES INC. CH1 ONLINE MANUAL SELECT CH2 SWITCH MANUAL

More information

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE 380/415/690 Volt AC 50/65/80/100 ka 1. Product Guide Low Voltage Motor Control Centre CONTSTRUCTION Continuous "poured in place" gasket

More information

Alarm Panel Operating Instructions

Alarm Panel Operating Instructions Alarm Panel Operating Instructions 1.0 Introduction The Gascon Systems G8850 alarm panel is designed to be used with gas reticulation systems. It is available in single, twin and triple input channel models.

More information

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001 SLATE Base Module R8001A1001 INSTALLATION INSTRUCTIONS Scan for more information Application SLATE brings configurable safety and programmable logic together into one single platform. The platform can

More information

TECHNICAL DATA OBSOLETE

TECHNICAL DATA OBSOLETE Deluge Devices 270a 1. PRODUCT NAME VIKING PAR-3 Available since 1991 2. MANUFACTURED FOR: THE VIKING CORPORATION 210 N. Industrial Park Road Hastings, Michigan 49058 U.S.A. Telephone: (269) 945-9501 (877)

More information

3G GSM AUTO DIALER. Remote monitoring & Control using your mobile phone. MODEL NUMBER 3GAD1

3G GSM AUTO DIALER. Remote monitoring & Control using your mobile phone.   MODEL NUMBER 3GAD1 3G GSM AUTO DIALER Remote monitoring & Control using your mobile phone www.gsm-activate.co.uk MODEL NUMBER 3GAD1 PAGE 1 Product Information Our 3G GSM Auto Dialer is a versatile unit which can be attached

More information

Brivis Touch Controller. Installer Manual

Brivis Touch Controller. Installer Manual Brivis Touch Controller Installer Manual Brivis Touch Controller Kit Scope Please read these instructions carefully before installing this product. This manual covers the installation of the wall mounted

More information

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F II 1400-2 ACSI 1406-04-AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F INSTALLATION Transformer Model BE31763001 by Basler Electric, Transformer Model 2010028 by Galaxy

More information

CATALOGUE. Request to Exit Products Relays, Fuses & Timers TROJAN DEVELOPMENTS Product Catalogue.

CATALOGUE. Request to Exit Products Relays, Fuses & Timers TROJAN DEVELOPMENTS Product Catalogue. CATALOGUE 2018 Product Catalogue Request to Exit Products Relays, Fuses & Timers CONTENTS Table of Contents Introduction: 3 Request & Emergency Egress Devices: Prox Rex 4 Press Rex 5 Em Rex 6 Smart Em

More information

ACM8 & ACM8CB. Access Power Controllers Installation Guide. - Fused Outputs - Fused Outputs. - PTC Outputs - PTC Outputs. Models Include: Rev.

ACM8 & ACM8CB. Access Power Controllers Installation Guide. - Fused Outputs - Fused Outputs. - PTC Outputs - PTC Outputs. Models Include: Rev. ACM8 & ACM8CB Access Power Controllers Installation Guide Models Include: ACM8 ACM8E - Fused Outputs - Fused Outputs ACM8CBE ACM8CB - PTC Outputs - PTC Outputs Rev. 092503 Overview: These units convert

More information

Quality Endorsed Company ISO 9001 Lic. No. 5403

Quality Endorsed Company ISO 9001 Lic. No. 5403 Quality System AQUARIUS 950BW Boiler Water Controllers Quality Endorsed Company ISO 9001 Lic. No. 5403 Microprocessor Control for Automatic Blowdown and Chemical Dosage on Steaming Boilers rated up to

More information

GSM 3G AUTO DIALLER. Remote monitoring & Control using your mobile phone. MODEL NUMBER 3GAD1

GSM 3G AUTO DIALLER. Remote monitoring & Control using your mobile phone.   MODEL NUMBER 3GAD1 GSM 3G AUTO DIALLER Remote monitoring & Control using your mobile phone www.gsm-activate.co.uk MODEL NUMBER 3GAD1 PAGE 1 Product Information Our GSM 3G Auto Dialer is a versatile unit which can be attached

More information

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual BS-316 Gas detection control panel up to 16 inputs Installation operation manual Page 1 from 21 Contents 1 Operation instructions--------------------------------------------------------------------------------------------------------------------3

More information

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev Installation Guide for AL800UL-ADA NAC Power Extender Rev. 090500 Overview: The Altronix AL800UL-ADA is an extremely cost effective 8 amps voltage regulated remote power supply /battery charger. The AL800UL-ADA

More information

5000 INSTALLATION GUIDE

5000 INSTALLATION GUIDE 5000 INSTALLATION GUIDE Table of Contents Section Page No 1. INTRODUCTION... 3 2. WARNINGS AND CAUTIONS... 3 3. UNPACKING... 3 4. INSTALLATION... 4 5. CONTROL PANEL - REMOVING ITEMS BEFORE MOUNTING...

More information

AL600ULADA. NAC Power Extender. Installation Guide

AL600ULADA. NAC Power Extender. Installation Guide AL600ULADA NAC Power Extender Installation Guide Rev. 122000 AL600ULADA - NAC Power Extender Overview: The Altronix AL600ULADA is an extremely cost effective 6.5 amp voltage regulated remote power supply/battery

More information

Operating Instructions

Operating Instructions Operating Instructions System 57 Module Kit (05701-A-0309) Alarm Update Panel (05701-A-0339) Helping to make a safer world Ensure that you read and understand these instructions BEFORE operating the equipment.

More information

Heat Sensor Cable Alarm Units DT650L / DT950L

Heat Sensor Cable Alarm Units DT650L / DT950L Heat Sensor Cable Alarm Units DT650L / DT950L For conventional and 950 series analogue addressable systems Installation and Commissioning Manual Version 2.1 / May 2004 http://www.geindustrial.com/ge-interlogix/emea

More information