1 ITROUCTIO From very initial, we were very keen about the Security. As generation is going towards the modernization, we want to secure each life by latest technologies, in the field of safety & security products company has taken the responsibility of fire detection & alarm system by using Hi-Tech superior technologies. ABOUT THE COMPAY:- We proud to introduce ourselves, as (Brand name: AI SURAKSHA) a well known name in the field of fire alarm system. We are in this field from last 12 years. We have reached the remarkable height because of our professionalism and best qualities of one products. We have our own R & department for Researching technologies, Programming & quality control assurance. ow a days, Agni Suraksha is one of the most popular brand in the market. Agni Suraksha is continuously appointing ealers Authorized System integrator all over India. For getting knowledge of our product range you can visit our website There are wide ranges of our products according to the requirement of customer. We manufacturers conventional as well as semi Addressable Fire etection & Alarm Systems. ABOUT THE PROUCT ASES is very proud of to introduce FIRE SCA the completely digital microprocessor based panel in Indian fire industry by using the digital technology. FIRE SCA can give you accuracy in its performance. For the ease of user there are 16 x 2 character LC display in the panel by which situation can be visually identify as well as LE. indications are also available. There are control switches in front of panel for handling ZOE ISOLATE, ALARM ACKOWLEE, LAMP TEST A RESET. There are LE display for MAIS O, SYSTEM O, LOW BATT, FIRE, CHARER O and Fault conditions in the panel. The size & look of this panel is designed by our Engineers keeping in mind that even a single thing not to disturb attraction of the location. ASES hope the satisfaction from user of this panel. This instruction manual will guide you to understand your system well. 437/2, Main Road, Mandawali Fazalpur, elhi Page 1
2 FEATURERS: 1. Fully confirms IS Operates on 230 V AC, 50 Hz AC supply 3. Battery backup with built in charger 4. Fire / fault status in unambiguous colored LE indications x 2 line dot matrix LC display 6. Zone wise fire, open, short LE indications. 7. External s/w to test each zone fire, open, short status manually. 8. External s/w for reset, Silence, Lamp test. 9. Zone isolation facility with loop voltage cutoff. 10. Relay O/P for actuators. 11. Mains on, System On, Charger on, visual indications. 12. Battery Low& Common fire indications 13. Auto dialer attachable facility 14. Enough inside space for battery 15. Attachable with all types of fire detectors. MECHAICAL COSTRUCTIO The enclosure of the Panel is constructed by CRCA sheet with powder coated finish. The20mm knock outs are given for cable entry at the top of the cabinet. The panel also has a built in battery provision to accommodate 2 os. of 12v, 7Ah batteries. The front side of the panel consists of the following: a. Tactile switches. b. LE indications c. 16X2 line dot matrix LC ISTALLATIO A COMMISSIOI: ISTALLATIO The installation of the fire detection and alarm should comply with: a. The Institute of Electrical Engineers (IEE) wiring regulation. b. The Indian Standard of Fire etection and Alarm for building. c. The installation cable should not be in the area of proximity of high voltage cable or induce electrical interference. Place the panel in its mounting position and fix the panel to the wall using the slots of the four screws. Ensure the enclosure and the inner parts of the panel are given sufficient protection during installation period. All external cables are to be entered via the 20mm preformed knockouts located at the top of the panel. When the installation of all the cables has been completed, clean the interior of the enclosure ensuring all masonry debris and drilling swords are removed. 437/2, Main Road, Mandawali Fazalpur, elhi Page 2
3 COMMISSIOI Check the all entered wiring is correctly identified and also check the cables are free from fault conditions by a multimeter. Connect the external wiring into their respective terminals and ensure the End Of Line (EOL) resistor is placed at the last device of circuit. Prior to the initial power up of the panel, conduct the following preliminary checks: a. Check for any external signs of damage caused during installation b. Check all the PCBs are secure in its monitoring position c. Check the cables are secure and correctly connected. d. Check all the cable termination is tight & secure. e. Connect the batteries ensuring the correct polarity. All damages/faults must be rectified before proceeding Switch O the Panel. uring this period the following LE s have to glow to ensure system is in healthy condition. A. SYSTEM O B. AC POWER C. CHARER O ote: Apart from the above green LE s if any other amber or red LE is O, it is indicating respective fire or faults. Rectify the fire or faults before proceeding to any other operation. IICATORS A COTROLS IICATORS ormal: In the ormal Condition, MAIS O, SYSTEM O, ZOE O green LE s will be illuminated along with CHARI O AMBER led. There should be no other amber/red LE visual indication or audible tone. Power Fault: When power fault conditions like AC Zone Fault: When the fault OPE/SHORT is occurred in the zone, it will be identified by zone fault LE. The fault zone LE will glow continuously until the fault is rectified. ote: uring the above fault condition, apart from the specific fault identification LE, common fault relay and Local buzzer with intermittent tone will be activated. uring this time, if SILECE is activated, intermittent tone will be silenced. Fire: When Fire is detected by the control panel via the etector/mcp, the corresponding zone fire red LE will be illuminated along with the commom fire red LE. By the time hooter, potential free contact and local buzzer (continuous tone) will be activated. If SILECE is accepted by the panel after the fire, it will mute the external hooters and internal buzzer. It can be identified by silenced LE O. The FIRE LE indication will remain O condition till the panel is RESET. 437/2, Main Road, Mandawali Fazalpur, elhi Page 3
4 Isolation: The zone isolation can be identified by the Zone ISOLATE LE of amber colour. The O status indicates, the zone is isolated from the monitoring with loop voltage cut. The OFF status indicates, the zone is in monitoring condition. COTROLS: RESET Key: This key is used to reset the entire system. While in reset condition, all detector loop voltages are cut off up to 2 seconds for etector and MCP become reset and then voltages are put O to the loop. ote: We strongly recommend to avoid to do the RESET unless there is fire in the zone. SILECE Key: While in the faults condition, when it is pressed, the local buzzer will be silenced. uring in fire condition, the SILECE Key press mutes the external hooters and silence LE lows. LAMP TEST Key: As long as we are keeping this key in hold condition, all the LE s will glow to identify whether all the LE s are in working condition or not. ZOE TEST: For this function there are seven switches of thw different types. Four switch nemed TEST is for every zones & three other- FIRE, OPE, SHORT for test condition. Exm: For testing zone-1 fire steps to be followed- Press the zone-1 TEST switch followed by FIRE switch at the same time. B: Zone-1 fire LE will glow up, external sounder will be activated & internal buzzer will also be activated in different tone. These three condition will continue until the switches are left free. The above process will be same for OPE/SHORT condition testing for any zone. TECHICAL ATA Panel Operating Condition Operating Voltage AC Power : 220v AC, 50Hz ± 10% Standby : 24v C Operating Temperature : 0 C to 40 C Operating Humidity : 95% (non-condensing) Zone Operating Condition ormal Loop Voltage : 23v C Open Threshold Current : 4.4 ma Short Threshold Current : 35 ma Fire Threshold Current : ma Alarm Outputs Hooter Output : 1 A (24v C) (ormal) B: Hooter output current can be increased as per customer requirement. Remote Outputs Fire Contact1 (C,O,C) : 240v AC/24v C@ 5A Fault Contact (C,O,C) : 240v AC/24v C@ 5A 437/2, Main Road, Mandawali Fazalpur, elhi Page 4
5 eneral Weight Size Color : Kgs (approximate) : x x mm (width x height x depth) : Broken white / Red COECTIO IARAM: Z1 Z2 Z3 Z4 H FIRE FAULT C C O C C O 1 220vAC 2 50Hz 3 X-mer 4 I/P 5 X-mer 6 O/P 12vC 24vC Batt O S: * The panel and detectors should be within the temperature range of 0 C to 40 C. * We strongly recommends you to check the panel on daily basis and the detectors on weekly basis. *Ensure 230 voltage input level before switching O the Panel. If the voltage fluctuation is more than 10% use UPS supply or voltage stabilizer. O T: *on t fix the panel/ detector in high range of vibrating area *on t put the panel cables near to the high voltage area *on t fix the panel in highly moisture surrounded area *on t connect the power cable wrongly, this will brake the warranty 437/2, Main Road, Mandawali Fazalpur, elhi Page 5
6 437/2, Main Road, Mandawali Fazalpur, elhi Page 6
GAS SUPRESSION CONTROL PANEL:
GAS SUPRESSION CONTROL PANEL: MODEL NAME: COMPANY: DELTA 437/2, Main Road, Mandwali Fazalpur, Delhi-110092 Page 1 ABOUT THE PRODUCT ASES is very proud of to introduce DELTA the completely digital microprocessor
More informationRE 102 RE Fire Alarm Control Panel. Installation, Commissioning & Operating Manual
RE 102 RE - 104 Fire Alarm Control Panel Installation, Commissioning & Operating Manual 1 NOTES: 2 Table of Contents CHAPTER 1: Introduction......4 1.1: System Design & Planning...4 1.2: General....4 1.3:
More informationFire Alarm Control Panel. Installation, Commissioning & Operating Manual
RE 150D Fire Alarm Control Panel Installation, Commissioning & Operating Manual RAVEL ELECTRONICS PVT LTD., 150-A, Electronics Industrial Estate, Perungudi, Chennai - 600 096. Ph.: 91-44-24961004, 24960825.
More informationFire Alarm Control Panel. Installation, Commissioning & Operating Manual RAVEL ELECTRONICS PVT LTD.,
RE 120GR Fire Alarm Control Panel Installation, Commissioning & Operating Manual RAVEL ELECTRONICS PVT LTD., 150-A, Electronics Industrial Estate, Perungudi, Chennai - 600 096. Ph.: 91-44-24961004, 24960825.
More informationExcel-EN Conventional Fire Control Panel
Available as 2, 4, 6, 8,10 or 12 zones Approved to EN54-2 & 4 Modular expansion zone cards Programmable relays and outputs Optional additional sounder circuits Optional additional programmable outputs
More informationLC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV
LC1 & 2 Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV ZIRCONLC1 One Zone Conventional Fire Panel ZIRCONLC2 Two Zone Conventional Fire Panel Compliant with EN54-2:1998 & EN54-4:1998
More informationInstallation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels
Installation and user manual for the FX range of fire panels 1, 2, 4 and 8 zone panels Contents Panel installation 3 Panel connections 3 Wiring connection drawings 4 Panel facilities 6 Installation check
More informationFTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS
QUICK USER GUIDE FOR, 2 & 4 ZONE PANELS INDICATORS COLOUR INDICATION MON FAULT Yellow On when a fault condition has occurred, or if no other fault Led is on, this indicates 24v auxiliary fuse failure.
More informationBT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL
BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL 26 Aug 2015 V1.8 Page 1 SECTION CONTENTS PAGE NO. 1.0 SYSTEMS DESCRIPTION 1.1 General descriptions 2 1.2 Master Alarm PCB 2 1.3 Zone Display Board 2 1.4
More informationInstallation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels
CF5000, MF5000 and FXP5000 Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels 16 zone panels Contents PANEL INSTALLATION...3 Installation...3 PANEL WIRING... 3 Mains power
More informationElectric Release Panel Wiring Tips
R IPS CARBO STEEL PIPE FIRE PROTECTIO PRODUCTS Electric Release Panel Wiring Tips 30.4 VICTAULIC IS A ISO 900 CERTIFIED COMPAY Model PDRP-00 Releasing Panels are compact single enclosure units containing
More informationInstallation, Operating and Maintenance Manual
STATUS ZONES CONTROLS FIRE FAULT DISABLED FIRE 1 2 3 4 5 6 7 8 TEST FAULT DISABLED 1 5 BUZZER SILENCE RESET 1 2 TEST 2 6 LAMP TEST 3 SUPPLY 3 7 SYSTEM FAULT 4 8 SOUNDERS ACTIVATE/ SILENCE 4 FAULTS INSTRUCTIONS
More informationSigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009
Sigma K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels Operation and Maintenance Manual Man-1048 Issue 05 October 2009 CONTENTS Contents... Page Safety & Installation...2 Installation - continued...3
More informationINTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3
INTELLIGENT FIRE TECHNOLOGY Twinflex and Multipoint V3 User Guide (TO BE RETAINED BY USER) 26-0340 Issue 3 Rafiki Protection Limited Rafiki policy is one of continual improvement and the right to change
More informationOPERATION AND INSTALLATION MANUAL
EX+Plus 2 ZONE, 1AREA EXTINGUISHANT CONTROL PANEL OPERATION AND INSTALLATION MANUAL INTRODUCTION The Premier EX Plus is a 2 zone, single area panel for controlling the release of extinguishing gases in
More informationPower Supply / Battery Charger Units, incorporating load switching relays for Smoke Dispersal, Bell Booster or other uses
BCU Power Supplies Power Supply / Battery Charger Units, incorporating load switching relays for Smoke Dispersal, Bell Booster or other uses Installation, Commissioning and Operating Manual BCU RANGE OF
More informationRE-120GR. Fire Alarm Control Panel. Installation, Commissioning & Operating Manual
RE-120GR Fire Alarm Control Panel Installation, Commissioning & Operating Manual 1 Fire Alarm System Limitations An automatic fire alarm system typically made up of smoke detectors, heat detectors, manual
More informationRE Fire Alarm Control Panel. Installation, Commissioning & Operating user Manual
RE - 700 Fire Alarm Control Panel Installation, Commissioning & Operating user Manual Fire Alarm System Limitations An automatic fire alarm system typically made up of smoke detectors, heat detectors,
More informationApplication, Installation, Operation & Maintenance Manual
APPROVED BY:JBJ PRESCIENT III FIRE ALARM & GAS EXTINGUISHING CONTROL PANEL Application, Installation, Operation & Maintenance Manual PAGE 1 of 43 CONTENTS 1. INTRODUCTION... 3 2. GENERAL DESCRIPTION...
More informationFIREBETA EXTINGUISHING CONTROL PANEL (ECP)
F I R E D E T E C T I O N A N D C O N T R O L FIREBETA EXTINGUISHING CONTROL PANEL (ECP) Three versions: 2 areas of detection and 1 area extinguishing 4 areas of detection and 1 area extinguishing 4 areas
More informationPNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel
PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel INSTALLATION, OPERATION AND MAINTENANCE MANUAL Version: CN-PM-1000.VER1.1-12/2012 EN54 INFORMATION In accordance with EN 54-2 clause 13.7, the maximum
More informationThe ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features
990-052, Issue 6 20 March 2006 ID50 Series Single Loop Intelligent Fire Alarm Panels Section: Intelligent Fire Alarm Panels GENERAL The NOTIFIER ID50 series single loop intelligent fire alarm panels, has
More informationEXTINGUISHING AGENT RELEASE MODULE
EXTINGUISHING AGENT RELEASE MODULE Operation, Installation & Programming Manual Revision 3.00 Distributors For: 18-20 Brookhollow Ave telephone 02 8850 2888 www.firesense.com.au Baulkham Hills NSW 2153
More informationSystem 800 Addressable Fire Detection & Alarm System
SECTION 5: page 1 Section 5: System 800 Addressable Fire Detection & Alarm System SECTION 5: page 3 10 reasons to specify 800 1 Plug and Play A user friendly panel not requiring special software tools
More informationConventional Fire Alarm System 2014 V1.2
Conventional Fire Alarm System 2014 V1.2 Product Overview Control Panel 2 Conventional Fire Panel GST102A 2 zone Fire panel GST104A 4 zone Fire panel GST108A 8 zone Fire panel GST116A 16 zone Fire Panel
More informationDoor Release Power Supply
www.protectingpeople.co.uk Door Release Power Supply Engineer / Installation Manual Document: VI55.1 Protecting People Printed : 04/03/2004-1 - Ventcroft Ltd Door Release Power Supply Engineer / Installation
More informationIntelligent Security & Fire Ltd
full installation, commissioning and operating manuals can be downloaded from www.haes-systems.co.uk combined addressable / conventional fire alarm control panel User Guide Approved Document No. MFBU-04
More informationHydrosense. Vimpex Limited. Star Lane. Great Wakering. Essex SS3 0PJ. Tel: +44 (0) Fax +44 (0)
Overview of the Water Detection System 2 Components of a System 4 Design & Planning 5 System Installation Notes 7 Control Panel Installation - HSCPI-K3000 8 Control Panel Commissioning HSCPC-K3000 11 Front
More informationFEC400 Series. Installation Manual
FEC400 Series Conventional microprocessor controlled fire detection and alarm panels with extinguishing control Installation Manual Version 2.3 / August 2004 Aritech is a GE Interlogix brand. http://www.geindustrial.com/ge-interlogix/emea
More informationMAG2/4. AL MAG2 Soft. Version 2.1 MAG4 Soft.Version 2.0 USER MANUAL
FIRE CONTROL PANEL MAG2/4 USER MANUAL AL MAG2 Soft. Version 2.1 MAG4 Soft.Version 2.0 READ THIS MANUAL BEFORE CONNECTING THE EQUIPMENT AND KEEP IT SAFE FOR FUTURE REFERENCE. To call our technical support
More informationLEAKSTOPPER MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND OPERATION MANUAL
LEAKSTOPPER MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND OPERATION MANUAL The LeakStopper Multizone detects the presence of water in environments where it is not supposed to be. Should water
More informationLEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL
LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL The LeakMonitor alarm panel is a microprocessor controlled fully adjustable alarm system suitable for multizone
More informationConventional Fire Control Panel (FKEP2, FKEP4, FKEP8) Operation and Maintenance Manual. Man-1078EL Issue 01 February 2014
Conventional Fire Control Panel (FKEP2, FKEP4, FKEP8) Operation and Maintenance Manual Man-1078EL Issue 01 February 2014 B Index Page 1. Introduction... 3 1B2. Safety and mounting... 3 2B3. Technical specification...
More informationORENA BRAND CONVENTIONAL (ORENA Brand) CE
ORENA BRAND CONVENTIONAL (ORENA Brand) CE ODH02E 2 Zone Conventional Control Panel Zone Capacity: can be connected with 20 fire detectors and infinite manual call points Using environment: Temperature:
More informationFire Alarm Control Panel. System Maintenance and Log Book
Fire Alarm Control Panel System Maintenance and Log Book Fire Alarm System Maintenance A fire alarm system must provide early and reliable warning of the outbreak of fire. To achieve this, the system remains
More informationTECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel
CVENTIAL ALARM S Features: Description: The LF-CP Series Fire Alarm Control Panel is manufactured based on advanced technology while maintaining high quality during assembly. It is of solid state circuitry
More informationPrecept Marine Control Panel Application Guide
Precept Marine Control Panel Application Guide Contents Page 1.0 Cabinet Specifications 2 2.0 Panel Hardware Specifications 5 3.0 Panel Configuration 8 4.0 Technical Specifications 8 5.0 Battery Sizes
More informationThe Remote alarm Panel, TYPE RAPv2
1. Introduction The Remote alarm Panel, TYPE RAPv2 The microprocessor based remote monitor from Metron Eledyne is the latest version of a whole line of successful products, marketed previously under the
More informationINSTRUCTION MANUAL FIRE ALARM CONTROL PANEL NATIONAL MODEL : DIGITAL ERTL APPROVED AS PER IS: NATIONAL SECURITY DEVICES
INSTRUCTION MANUAL FIRE ALARM CONTROL PANEL MODEL : DIGITAL NATIONAL NATIONAL SECURITY DEVICES ERTL APPROVED AS PER IS:2189-1999 Manufucturer of fire alarm panel & Accessories CONTENTS 1. Introduction
More informationFire Alarm Control Panel EN54 2 & Operation & Programming MAN
ZoneSense PLUS Fire Alarm Control Panel EN54 2 & 4 1997 Operation & Programming MAN 2374-10 Responding to an Alarm 1. Indicators FIRE FIRE ZONE 1 ZONE 2 FAULT/DISABLED/ Z2 ZONE SEVEN Common Fire Indicator
More informationQA16 Addressable System
QA16 Addressable System Operating Manual HORING LIH INDUSTRIAL CO., LTD. www.horinglih.com QA16 System Characteristics Each loop can connect with 250 devices. Easy system programming through PC to panel.
More informationIntelligent Security & Fire Ltd
OPERATIONAL NOTES FOR CONCEPT FIRE PANEL. NOTE ON NEW FIRE PANELS, POSITION 1 ON THE SIX WAY INTERNAL OPTION SWITCH IS TURNED ON, DISABLING THE ZONAL SOUNDERS. TO ENABLE ZONAL SOUNDERS TURN OFF. Operation
More informationPrem1er EVACS16. Installation Manual VOICE ALARM CONTROL PANEL 4 16 ZONES
Prem1er EVACS16 VOICE ALARM CONTROL PANEL 4 16 ZONES Installation Manual Approved Document No: GLT.MAN-141 PAGE 1 INDEX INDEX... 2 Summary... 3 Safety information & use of this manual... 5 Installation
More informationRE 2554 RE Automatic Fire Alarm Control Panel (Protective premises Unit) Installation, Commissioning & Operating User Manual
RE 2554 RE 2558 Automatic Fire Alarm Control Panel (Protective premises Unit) Installation, Commissioning & Operating User Manual Fire Alarm System Limitations An automatic fire alarm system typically
More informationCONVENTIONAL CONTROL PANEL FL2/4/8/12 LT-XP
FLx-LT-XP CONVENTIONAL CONTROL PANEL FL2/4/8/12 LT-XP Installation, Configuration and Operating Manual MAY 2008 MIE-MI-580I_FL rev.003 Information in this document is subject to change without notice.
More informationSYSTEM 3400 ANALOGUE ADDRESSABLE FIRE DETECTION. (with Devices) Operating Manual Version 3.3X Issue 2 September 1996
User responsibility SYSTEM 3400 (with 34000 Devices) Control and indicating equipment Quick reference Emergency conditions ANALOGUE ADDRESSABLE FIRE DETECTION AND ALARM SYSTEM Other controls Site labels
More informationOperating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels
Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels The panels are designed in accordance with the requirements of EN54 Part 2:1997 (and include optional clauses
More informationFire Control Panel. Installation & Programming Manual TABLE OF CONTENTS
Fire Control Panel Installation & Programming Manual TBLE OF CONTENTS Page Getting Started 2 Power Supply Unit 3 Inputs 4 Outputs 4 LED Indications 4 User Keypad Functions 5 Engineer Keypad Functions 6
More informationSurveyor Envoy-MINI 4
Surveyor Envoy-MINI 4 CONTENTS SECTION 1 INTRODUCTION Page 4 About this manual Page 4 System design and planning Page 4 Panel types Page 4 General Page 4 SECTION 2 INSTALLATION Page 5 General Page 5 ESD
More informationSaffire User & Installation Manual. IMPORTANT This manual should be left with the panel after installation.
Saffire+ 8-12 User & Installation Manual IMPORTANT This manual should be left with the panel after installation. We reserve the right to change product specifications without prior notice. Copyright VRC
More informationFire Product Catalog
Additional Expansion Modules Fire Product Catalog CLEVER FIRE SOLUTIONS MA 1000 / Analog Addressable Fire Alarm Panel 1 Military Industry Public Buildings Industrial & Commercial Company Profile We are
More informationFIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module
FIRE ALARM CONTROL EQUIPMENT Addendum October 2006 Instructions for new style EN54-4 Power supply unit module MXLK-05 Issue 2.0 June 2007 INSTALLATION Safety Suppliers of articles for use at work are required
More informationDMWD 1 to 4 Zone Water Detection Alarm with Distance to Leak Measurement Installation and Operation Manual
CMR Electrical Ltd Bolton House Five Chimneys Lane Hadlow Down East Sussex TN22 4DX Tel: 01825 733600 DMWD 1 to 4 Zone Water Detection with Distance to Leak Measurement Installation and Operation Manual
More informationControl Panel Engineering and Commissioning Instructions
Twinflex - V3 Fire Detection & Alarm System Control Panel Engineering and Commissioning Instructions (TO BE RETAINED BY THE COMMISSIONING ENGINEER) 26-0338 Issue 9 Fike s policy is one of continual improvement
More informationFire Control Panel. Installation & Programming Manual TABLE OF CONTENTS
Fire Control Panel Installation & Programming Manual TABLE OF CONTENTS Page Getting Started 2 Power Supply Unit 3 Remote Keypad Bus 3 Inputs & Outputs 4 User Keypad Functions 5 Engineer Keypad Functions
More informationVoCALL - CFVCC5. Compact 5 Line Exchange Unit. Installation & Commissioning Manual
VoCALL - CFVCC5 Compact 5 Line Exchange Unit Installation & Commissioning Manual Introduction A VoCALL Emergency Voice Communications System (EVCS) is a fixed, secure, bi-directional, full duplex voice
More informationInstallation and Operating Instructions
Twinflex and Multipoint Installation and Operating Instructions Rafiki Protection Limited 55 Springvale Industrial Estate Cwmbran South Wales NP44 5BD United Kingdom Tel. (+44) 01633 865558 Fax (+44) 01633
More informationTechnical Speci fications 220V AC 50Hz or 110V AC 60Hz Accessories operational voltage. 2x 12V / 7Ah sealed lead acid gel batteries
EN54 General Speci fications Advanced analog fire alarm control panel for small or medium installations. Number of zones: 4, 8, 12, 16, 20 or 24. Maximum number of detectors per zone 20. Two wire zone
More informationFSTP2-2-wire 2 Zone Conventional Fire Control Panel Operation and Maintenance Manual. Man-1078FS2 Issue 01 April 2012
FSTP2-2-wire 2 Zone Conventional Fire Control Panel Operation and Maintenance Manual Man-1078FS2 Issue 01 April 2012 Index Page 0B1. Introduction... 3 1B2. Safety and mounting... 3 2B3. Technical specification...
More informationMatrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1
Matrix2000 User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 s Version: 2.0 Revision: 1 IMPORTANT INFORMATION Limitation of liability It is mandatory, Matrix2000 panel to be installed in accordance
More information3200 NON-ADDRESSABLE FIRE ALARM CONTROL PANEL
3200 NON-ADDRESSABLE FIRE ALARM CONTROL PANEL USER MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax: +44 (0) 1282 717273 Web:
More informationUSER MANUAL & MAINTENANCE GUIDE OG OO
M+48. USER MANUAL & MAINTENANCE GUIDE OG OO What to do if the Fire Alarm Panel shows an Alarm (Red LED) Write down which LEDs are lit (either in the log book, or on a piece of paper for transferring to
More informationFSTP4-2-wire 4 Zone Conventional Fire Control Panel Operation and Maintenance Manual. Man-1078FS4 Issue 01 April 2012
FSTP4-2-wire 4 Zone Conventional Fire Control Panel Operation and Maintenance Manual Man-1078FS4 Issue 01 April 2012 Index Page 1. Introduction... 3 2. Safety and mounting... 3 3. Technical specification...
More informationED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR
ED820 24V MODEL fire DETECTOR INSTRUCTION MANUAL Address: Enigma House, Enigma Business Park, Malvern, Worcestershire, WR14 1GD Tel: 44 (0)1684 891500 Fax: 44 (0)1684 891600 Email: sales@electronicdevices.co.uk
More informationFeatures. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign
Features DATASHEET Connects to multiple sensing instruments One/Two Channel Device Bright solid state LED Alarm Display Audible Alert (internal and external) High reliability, fully dual redundant alarm
More informationCONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA
CONVENTIONAL FIRE ALARM CONTROL UNITS MR-2300 SERIES Fire Alarm Control Units Description Secutron s MR-2300 Series fire alarm control panels consist of six and twelve zone models which are equipped with
More information3500 CONVENTIONAL FIRE ALARM CONTROL PANEL
3500 CONVENTIONAL FIRE ALARM CONTROL PANEL INSTALLATION AND COMMISSIONING MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax:
More informationDocument No Issue 02 operation & installation manual. ZXr-A ZXr-P
ZXr-A ZXr-P Document No. 996-144 Issue 02 operation & installation manual MORLEY-IAS ZXr-A / ZXr-P Repeaters Table of Contents 1 INTRODUCTION... 3 1.1 NOTICE... 3 1.2 WARNINGS AND CAUTIONS... 3 1.3 NATIONAL
More informationAn introduction to... Sigma
An introduction to... Sigma XT+ Sigma XT+ Overview The Sigma XT+ 21000 series are the latest additions to the Sigma family of control equipment from Kentec Electronics Limited. The Sigma XT+ range combines
More informationIFP-2.32 Manual 1) DESCRIPTION ICAS FIRE PANEL IFP 2.32
1) DESCRIPTION IFP-2.2 Manual IFP-2.8 and IFP-2.2 is a microprocessor controlled Fire Panel with 2 loops intended either for privat Homes & Apartments or larger installations. The two loops are balanced
More informationInstallation and user manual for the BiWire / Conventional Repeater Panel
Panel EFBWCV-REPEATER Contents Introduction.... 3 Purpose... 3 The Panel.... 3 Indication Equipment (IE).... 3 Power Supply Equipment (PSE).... 4 System Wiring.... 5 Status Indications.... 5 Repeater I/O....
More informationPAT E N T System 88. COMPLIES WITH Singapore Standard : SS CP10 : 2005 British Standard : BS EN54-2 : 1998 BS EN54-4 : 1998 REV.00
PAT E N T System 88 COMPLIES WITH Singapore Standard : SS CP10 : 2005 British Standard : BS EN54-2 : 1998 BS EN54-4 : 1998 REV.00 Pg 1 of 12 CONTENTS 1. GENERAL 1.1 Introduction 2 1.2 System Description
More informationNZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL
NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL Document No...G108WO1.DOC Serial No... Issue Date...17 th SEPTEMBER 1999 Software Version...1.4 APPROVED TO: NZS 4512:1997 AS/NZS 3548:1992 Fire Alarm
More informationBiWire Flexi. BiWire Flexi Fire Panel EFBW8ZONE-FLEXI / EFBW4ZONE-FLEXI / EFBW2ZONEFLEXI Installation Manual
BiWire Flexi BiWire Flexi Fire Panel EFBW8ZONE-FLEXI / EFBW4ZONE-FLEXI / EFBW2ZONEFLEXI Installation Manual Contents Contents 1. INTRODUCTION... 4 1.1 Purpose...4 2. THE BIWIRE FLEXI FIRE DETECTION & ALARM
More informationOperation and Maintenance Manual
(FKER Series) Repeater Panel (FKER, FKER, FKER8) Operation and Maintenance Manual Man-9EL Issue June Index Section Page. Introduction.... Safety and mounting.... Technical specification.... Control panel
More informationCW9000 Wireless Fire System. Installation Manual
CW9000 Wireless Fire System Installation Manual CONTENTS 1 PROJECT PROCESS...4 1.1 PLANNING...4 1.2 SITE SURVEY...4 1.3 EQUIPMENT INSTALLATION...4 1.4 COMMISSIONING / CONFIGURATION...4 2 SYSTEM INSTALLATION...5
More informationCONTENTS. GST102A/104A/108A/116A Conventional Fire Alarm Control Panel Installation and Operation Manual
CONTENTS Installation Precautions... 1 EN 54 Information... 2 Chapter 1 Product Overview... 3 1.1 Features... 3 1.2 Technical Specifications... 3 1.2.1 Operating Voltage... 3 1.2.2 Batteries... 3 1.2.3
More informationFire Alarm Panel - User Manual
CONTENTS Page No. INTRODUCTION SYSTEM DESIGN AND PLAN GENERAL FEATURES MECHANICAL CONSTRUCTION INSTALLATION AND COMMISSIONING INSTALLATION COMMISSIONING OPERATION POWER CONDITION ZONE LOOP CONDITION KEY
More informationFIRE CONTROL PANEL. Revision 1.1 January 1997 USER MANUAL. Emergi-Lite Safety Systems Ltd Bruntcliffe Lane Morley Leeds LS27 9LL
FIRE CONTROL PANEL Revision 1.1 January 1997 USER MANUAL Emergi-Lite Safety Systems Ltd Bruntcliffe Lane Morley Leeds LS27 9LL Tel: 0113 281 0600 Fax: 0113 281 0601 C O N T E N T S PAGE INTRODUCTION...
More informationNFS Supra / VSN-2Plus / ESS-2Plus Conventional Fire Alarm Control Panel. Installation and Operating Manual
/ VSN-2Plus / ESS-2Plus Conventional Fire Alarm Control Panel Installation and Operating Manual HLSI-MN-025-I v.05 April 2015 Note: This manual is valid for the following control panel models: NFS-Supra
More informationZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features
Fire Safety ZXSe Range Analogue addressable fire alarm control panel The ZXSe range of analogue addressable fire alarm control panels have been designed and constructed around proven and reliable microprocessor
More informationintelligent solutions
Alco is one of the leading intelligent solution providers of Fire Detection System. Security System and Public Addressing System in the United States of America. Based in California since 1992, we have
More informationTECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.
September 29, 1997 Firecycle III 433 a 1. PRODUCT NAME VIKING Model E-1 Manufactured 1997 Present 2. MANUFACTURED FOR THE VIKING CORPORATION 210 N Industrial Park Road Hastings, Michigan 49058, U.S.A.
More informationRE 25AR. Agent Release Control Panel (Protective premises Unit) Installation, Commissioning & Operating User Manual
RE 25AR Agent Release Control Panel (Protective premises Unit) Installation, Commissioning & Operating User Manual Fire Alarm System Limitations An automatic fire alarm system typically made up of smoke
More informationOperating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels
Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels The panels are designed in accordance with the requirements of EN54 Part 2:1997 (and include optional clauses
More informationSYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System
SYSTEM MANUAL FT1-SB Single Zone Fire Alarm System DOCUMENT HISTORY Issue Date Description Written By Checked By Draft 0 2/9/2008 Original Document. A. Shenouda C. Orr Issue 1 4/11/2011 Update drawing
More informationInterface Modules for SENTRI
EQUIPMENT INTERFACED Data and Installation Interface s for SENTRI Low voltage (LV) / SEN-INT-INPUT 1- Interface (low voltage) SEN-INT-OUTPUT 1- & 1- Interface (low voltage) SEN-INT-4IO # 4- / Interface
More informationAL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev
AL802ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 031703 Overview: The Altronix AL802ULADA is an extremely cost effective 8 amp voltage regulated
More informationThe EN54 Part 2 and 4 Fire System
Scope of work: To design, supply, install and commission a Fire Alarm Control System in accordance with the details specified herein and in accordance with supplied drawings The EN54 Part 2 and 4 Fire
More informationCONVENTIONAL FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels MEA. Features. Description
CONVENTIONAL FIRE ALARM CONTROL PANELS SFC-200 Series Fire Alarm Control Panels Description Summit s SFC-200 Series fire alarm control panels consist of six and twelve zone models which are equipped with
More informationRP1r-Supra / VSN-RP1r+ / ESS-RP1r-Supra Extinguishing Control Panel User Manual. HLSI-MN-103I v.06 September 2017
/ VSN-RP1r+ / ESS-RP1r-Supra Extinguishing Control Panel HLSI-MN-103I v.06 September 2017 Note Nota: This manual is valid for the following control panel models: RP1r-Supra VSN-RP1r+ (no touch screen)
More informationFIRE ALARM CONTROL PANEL FVC01-08
FIRE ALARM CONTROL PANEL FVC01-08 USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Radal Technology Limited Unit 1, Webber Court Billington Road, Burnley Lancashire, BB11 5UB Tel: +44 (0) 1282 463 770 Fax: +44
More informationTemporary wireless battery operated fire system from Channel Safety Systems
Temporary wireless battery operated fire system from Channel Safety Systems CHANNEL SAFETY SYSTEMS t: 0845 884 7000 Petersfield Business Park f: 0845 884 6000 Bedford Road Petersfield Hampshire e: sales@channelsafety.co.uk
More informationUSER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4
PREMIER EX8 EXTINGUISHING PANEL USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN 12094 PART 1 & EN54 PARTS 2 & 4 USER MANUAL Approved Document No: GLT.MAN-132 INDEX Extinguishing
More informationConventional Fire Control Panel
(FKEW Series) Conventional Fire Control Panel (FKEW2, FKEW4, FKEW8) Man-1138EL Issue 01 February 2014 Contents 1. Introduction... 4 2. Safety... 4 4. Technical specification... 5 5. Control panel fascia...
More informationThe EN54 Part 2 & 4 Fire System
Scope of work: To design, supply, install and commission an Analogue Addressable Fire Alarm Control System in accordance with the details specified herein and in accordance with supplied drawings The EN54
More informationZXSe Range Data Sheet
ZXSe Range Data Sheet Analogue addressable fire alarm control panel Product Overview The ZXSe range of analogue addressable fire alarm control panels have been designed and constructed around proven and
More informationLF-4000 Series Conventional Fire Alarm Control Unit
LF-4000 Series Conventional Fire Alarm Control Unit Features: 1 to 36 Zone Control Panels Control Key Switch Easy Push Button Control Switches Zone Circuit Monitoring for Open and Short Sounder Circuit
More informationAL600ULADA. NAC Power Extender. Installation Guide
AL600ULADA NAC Power Extender Installation Guide Rev. 122000 AL600ULADA - NAC Power Extender Overview: The Altronix AL600ULADA is an extremely cost effective 6.5 amp voltage regulated remote power supply/battery
More informationFunctional Performance Test
Fire Alarm Control Panel & Fire Alarm Annunciator Panel Notify all building occupants that testing will be conducted. Fire alarm contractor shall have personnel with 2-way radios at the fire alarm control
More information