Spectra FIA Light Engine Instruction Manual

Size: px
Start display at page:

Download "Spectra FIA Light Engine Instruction Manual"

Transcription

1 Spectra FIA Light Engine Instruction Manual Lumencor, Inc. Document Number

2 Emissions Certifications This equipment has been tested and found to comply with the limits of EMC directive 2014/30/EU. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Safety Certifications Models: Spectra FIA 5-NKJ-SA Spectra FIA 5-NKJ-SH TUV SUD America, CB Certification (IEC :2010) TUV SUD America, NRTLus Certification (UL : ) TUV SUD America, cnrtl Certification (CAN/CSA-C22.2 No :2012) TUV SUD America, EN Certification (EN :2010) CE Marking Low Voltage Directive (2014/35/EU) EMC Directive (2014/30/EU) RoHS Directive (2011/65/EU) REACH (Regulation (EC) No. (1907/2006/EC) EU Declarations of Conformity can be found at Lumencor, Inc NW Greenbrier Parkway Beaverton, OR T Document Number Spectra FIA Light Engine Instruction Manual 1

3 Table of Contents 1. Introduction 2. Precautions and Warnings 3. Installation and Operating Instructions 4. Spectral Distribution and Power Output 5. Temporal Response 6. Routine Maintenance and Trouble Shooting 7. Product Specifications 8. Customer Support 9. Warranty Spectra FIA Light Engine Instruction Manual 2

4 1. Introduction The Spectra FIA light engine consists of 5 individually addressable light sources with 4 individual LEDs and 1 luminescent light pipe. The output of these individual sources are combined with dichroics such that the light from each channel illuminates the entrance port of the two fiber bundles. These light sources are precisely mounted on a common heat sink. The circuit boards are mounted below the heat sink. The exhaust fan pulls fresh air from the front of the light engine across the heat sink fins and exhaust the heated air out the rear panel. The light sources within the Spectra FIA light engine are controlled by software; via one of two serial interfaces, RS-232 or TCP, to the onboard computer operating Lumencor firmware. The user can enable or disable each source independently by serial commands as well as change the intensity of each source independently. The only manual control is a power switch on the front panel to turn on/off the power into the unit. The Spectra FIA light engine can either be controlled by a Lumencor GUI or by a LAN connection to an onboard computer with an embedded command library. Spectra FIA Light Engine Instruction Manual 3

5 2. Precautions and Warnings {Précautions et mises en garde} A few simple practices will ensure trouble-free operation for the life of the light engine. Les quelques règles simples suivantes permettront d assurer un fonctionnement fiable pendant toute la durée de service de la source lumineuse. Safety Instructions: Please read and follow all safety instructions provided BEFORE using the Spectra FIA light engine. Failure to comply with the safety instructions may result in fire, electrical shock, or personal injury and may damage or impair protection provided by equipment. Please save all safety instructions. Instructions de sécurité: Veiller à lire et à respecter toutes les instructions de sécurité fournies AVANT d utiliser le Spectra FIA light engine afin d écarter les risques d incendie, de décharge électrique, de blessure corporelle et de possibles dommages ou défaillance de la protection offerte par l appareil. Conserver toutes les instructions de sécurité. Safety Definitions {Définitions relatives à la sécurité}: Warning: Statements identify conditions or practices that could result in personal injury. Avertissement: déclarations qui identifient des situations ou des pratiques susceptibles d entraîner des blessures corporelles. Caution: Statements identify conditions or practices that could result in damage to your equipment. Attention: déclarations qui identifient des situations ou des pratiques susceptibles d endommager le matériel. Safety Items {Mesures de sécurité}: Warning: DO NOT use an unapproved power supply. An external power supply is required for use with the Spectra FIA light engine. The power supply used must be capable of supplying 24VDC, 14A. The equipment is required to be supplied by an approved/certified DC power source meeting the minimum electrical ratings of the Spectra FIA Light Engine. Avertissement : NE PAS utiliser une alimentation non approuvée. Une alimentation externe est nécessaire pour une utilisation avec le Engine de lumière Spectra FIA. L'alimentation utilisée doit être capable de fournir 24VDC, 14A. L'équipement doit être fourni par un certifié DC réunion approuvé / source d'énergie les notes électriques minimales de la FIA Lumière Engine Spectra FIA. Warning: DO NOT look into the output of the light engine. The brightness of this light source is higher than most commercial lighting fixtures and is intended to couple directly into a microscope or other bioanalytjcal instrument. Avertissement: NE PAS regarde directement la sortie de la source lumineuse. L intensité lumineuse de cette source est supérieure à celle de la majorité des appareils d éclairage disponibles dans le commerce et est conçue pour un raccordement direct à un microscope ou autre appareil de bioanalyse. Spectra FIA Light Engine Instruction Manual 4

6 RISK GROUP 3 Warning: Possibly hazardous optical radiation emitted from this product. Do not look at operating lamp. Eye injury may result. Warning: Infrared (IR) emitted from this product. Do not look at operating lamp. GROUPE DE RISQUE 3 Avertissement: Infrarouge (IR) émise par ce produit. Ne regardez pas la lampe d'exploitation. Avertissement: Rayonnement optique Peut-être dangereux émis par ce produit. Ne regardez pas la lampe d'exploitation. Une blessure oculaire peut entraîner. Caution: DO NOT open the unit. There are no serviceable parts inside and opening the light engine enclosure will void the manufacturer s warranty. Attention: NE PAS ouvrir l appareil. Il ne contient aucune pièce réparable et l ouverture de son boîtier a pour effet d annuler la garantie. Caution: DO NOT set liquids on the light engine. Spilled liquids may damage your light engine. Attention: NE PAS placer de liquide sur la source lumineuse. Les liquides renversés peuvent endommager la source lumineuse. Caution: DO NOT drop the light engine. It contains glass optical components that could be damaged or misaligned by the shock produced by a drop onto a hard surface. Attention: NE PAS laisser tomber la source lumineuse. Elle contient des composants optiques en verre susceptibles d être endommagés ou désalignés par le choc résultant d une chute sur une surface dure. DISCLAIMER: Lumencor shall not be liable for injury to the user or damage to the product resulting from the Spectra FIA light engine being used in a way for which it was not intended and in complete disregard for all posted safety precautions and warnings. AVIS DE NON-RESPONSABILITÉ: Lumencor décline toute responsabilité pour les blessures corporelles ou les dommages au produit résultant d une utilisation du Spectra FIA light engine autre que celle prévue et du mépris total de toutes les mesures de sécurité et mises en garde affichées. Spectra FIA Light Engine Instruction Manual 5

7 3. Operating Instructions 3.1 Contents The Spectra FIA light engine ships with a 24 V/14 A DC Power Supply and DC power cable as follows: Spectra FIA Model Light Engine Part Number DC Power Supply DC Power Cable Spectra FIA 5-NKJ-SA Spectra FIA 5-NKJ-SH Lead Wire length (mm) GND 350 Figure 1. DC power cable (Part Number ) The model name, unique 4- or 5- digit serial number and certification markings of the light engine are carried on a label affixed to the rear panel (Figure 2). Performance specifications for individual light engines are listed on the certificate of conformance included with the shipping documents e- mailed to the customer. Figure 3 shows the external dimensions of the Spectra FIA light engine and the location of the air intake and exhaust. Also shown are the locations of the light output ports A and B and the power supply and communications port connectors. 3.2 Installation When setting the Spectra FIA light engine up for use, place the unit on a hard surface and avoid blocking or restricting airflow at the air inlets (front panel) or exhaust ports (rear panel) on the enclosure. Restricting the airflow will cause the unit to operate at elevated temperatures and will result in Figure 2. Specimen identification label located on the rear panel of the Spectra FIA light engine. Spectra FIA Light Engine Instruction Manual 6

8 decreased product life and/or premature failure. Thermal overload protection is provided by the on-board computer in conjunction with an onboard temperature sensor. If the internal temperature registered by the sensor exceeds 50 C OR the fan rotor is stopped, all light output channels automatically turn OFF and are locked in this state until the internal temperature is below 50 C and/or the fan restarts. The current reading of the on-board temperature sensor is displayed in the GUI (Figure 5) or can be accessed using the GET TEMP software command. Normal exhaust airflow (with all light sources operating at 100%) has been measured at 52.7 m 3 /hour with a temperature 6 C above ambient. Connect the DC power supply to the power input port (front panel, lower left corner) using the DC power cable (Lumencor part number or ). See Figure 2 for pin connections. Position the unit in such an orientation that allows unrestricted access to the DC power connector. In an emergency, you may ned to disconnect power to the unit quickly. Connect the DC power supply to the AC utility power. D C NOTES: 1. WEIGHT: APPROXIMATELY 15.5 LB 2. HEAT DISSIPATION: IDLE: (TBD)W MAX: (TBD)W 3. AIRFLOW: FRONT-TO-BACK, VIA INTERNAL FAN AT (TBD) CFM COOL AIR INTAKE SLOTS RJ45 DB GREEN LED "ON" STATUS POWER SWITCH 3X M3X X 90 FOR PRODUCTION FIBER TERMINALS 2X A ZONE REV DESCRIPTION DATE APPROVED A INITIAL RELEASE GST B A D C POWER INPUT TE CONNECTIVITY DYNAMIC D SINGLE ROW, 3 PIN PIN PIN B FRONT ENDPLATE ENCLOSURE CENTERLINE X OPTICAL AXIS FIBER TERMINAL INPUTS 2X X ENTRANCE OF FIBER BUNDLES B B A DIMENSIONAL TOLERANCES UNLESS OTHERWISE SPECIFIED: DECIMALS.XX.015.XXX.005" HOLE ANGLES PERPEND. FLATNESS.XX.XXX / / IN.005/ IN MACHINED SURFACES 63 µin MAX 5 PROPRIETARY NOTICE: THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF LUMENCOR. IT IS NOT TO BE USED, REPRODUCED, OR DISCLOSED IN WHOLE OR IN PART TO ANYONE WITHOUT THE PERMISSION OF LUMENCOR. MATERIAL: SEE COMPONENT DRAWING FINISH: SEE COMPONENT DRAWING DFT: CHK: ENG: G. TYLINSKI APR: DIMENSIONS ARE IN INCHES UNLESS OTHERWISE SPECIFIED. METRIC DIMENSIONS ARE mm AND ARE ENCLOSED IN [ ]. DIMENSIONS AND TOLERANCES PER ASME Y14.5M lumencor A FIA 5-COLOR LIGHT ENGINE MECHANICAL INTERFACE (PRODUCTION) DWG NO. REV B A DATE TITLE SIZE SCALE = 1:2 SHEET 1 OF Figure 3. Spectra FIA light engine schematic The Spectra FIA light engine has two identical light output ports A and B built directly into the light engine front panel (Figure 3). The ports are custom designed for connection to Nikon s fiber bundles. Each fiber bundle should be inserted Spectra FIA Light Engine Instruction Manual 7

9 all the way into the correct port and then 3 screws are used to mechanically attached the fiber bundle to the light engine. The insertion depth is set at the factory for optimum performance. 3.3 Operation The only manual control is a power switch on the front panel to turn the electrical power to the unit on or off. A green power indicator on the front panel is lit ( ON ) when the power supply is connected to the Spectra FIA light engine and the power switch is in the on position. Prior to turning the light output on, be sure the output end of the fiber bundle is safely directed into an enclosed optical path (e.g. a beam dump). The Spectra FIA light engine can either be controlled by a Lumencor GUI or via the built in library of software commands. A complete listing of the commands is provided in the Lumencor Light Engine Command Reference (Document Number ). The software commands can be Figure 4. Spectra FIA light engine control GUI screenshot transmitted via the RS-232 port or the LAN input. The default IP address for LAN communications is The current IP address can be determined using the GET IP command sent over RS-232. The RS-232 port conforms to the standard RS-232 interface protocol using standard RS-232 connector pin definitions. The default RS-232 port parameters are 9600,8,N,1. The RJ-45 port enables communication using Transmission Control Protocol (TCP). The GUI provides a quick and easy way to control the light engine providing the ability to turn each source on/off, adjust the power of each source independently from off to full power. The GUI also tracks the total on time and the power sensor readings. The GUI is accessed by typing in the IP address into a web browser (Figure 4). Spectra FIA Light Engine Instruction Manual 8

10 4. Light Output Spectral distribution and power measurements are measured at the distal end of the Nikon supplied fiber bundle. Guaranteed minimum output A power values are given in the adjacent table along with an output spectrum measured from one of the first production light engines (Figure 5). The two peaks in the red output band have an intensity ratio of 0.7 or more relative to the intensity of the stronger peak normalized to a value of Color Output A Power (mw)* Output B Power (mw)* Cyan Green Red NIR I NIR II TOTAL *Guaranteed minimum output power. Specific output A power measurements for individual light engines are recorded on the certificate of conformance included in the shipping documents e- mailed to the customer. Intensity (mw/nm) Cyan Green Red NIR I NIR II Wavelength (nm) Figure 5. Representative spectral output of Spectra FIA light engine Spectra FIA Light Engine Instruction Manual 9

11 5. Temporal Response The time to switch all 5 channels simultaneously was measured to be approximately 1.5 msec. The oscilloscope traces in Figure 6 show the initial trigger of the TCP pulse which is followed by the light pulse turning on or turning off. Figure 6. Temporal response to TCP commands. The oscilloscope trace marked in green represents the light output detected by an analog photodiode. 6. Routine Maintenance and Trouble Shooting Since this light engine will be used in a clean room, no maintenance will be required regarding the air intake and exhaust. There are no user-replaceable components or sub-assemblies in Spectra FIA light engine. Opening the light engine enclosure will void the manufacturer s warranty. Spectra FIA Light Engine Instruction Manual 10

12 7. Operational Specifications The Spectra FIA light engine must be operated and stored within the environmental conditions specified. Specification Detail Ambient Temperature Operating 32 to 95 F (0 to 35 C) Non-operating -4 to 158 F (-20 to 70 C) Humidity Operating and non-operating 0 to 80% relative humidity, non-condensing Altitude Operating Non-operating Dimensions (LxWxH) Weight Lifetime 0 to 10,000 feet (3,048 meters) 0 to 45,000 feet (13,176 meters) 390 mm x mm x mm 15.5 lbs / 7.05 kg Designed for > 20,000 hours light output*. Contains no components with MTBF less than 7 years. Input Power Requirements Power supply, max voltage Warm-up Period 24 VDC, 14 A, maximum internal voltage and current draw use dependent Protection thermal overload (see Section 3.2) Shock and Vibration Resistance Sound Level Connectivity Light engine and packaging pass ISTA 3A test to be determined RS-232, TCP Default IP address Warranty 18 months parts and labor *Pulse mode light output with one color on at a time at 100% intensity. Based on information available at the date of publication. MTBF = mean time between failure. 8. Customer Support For technical support of the Spectra FIA light engine, please contact Lumencor by phone at or through e-, mail at techsupport@lumencor.com. Please be prepared to provide the 4- or 5-digit serial number of the light engine (see Figure 2). Any light engine returned to Lumencor for service requires a manufacturer s issued return material authorization (RMA) number. An RMA number must be issued before returning a unit to Lumencor. To obtain a RMA Spectra FIA Light Engine Instruction Manual 11

13 number, submit the online request form at It is the customer s responsibility to properly package and safely ship products to Lumencor. Instructions for shipping will be provided in the giving notification of the RMA number. 9. Warranty The Spectra FIA light engine family of light engines is backed by an 18 month warranty. Warranty coverage starts on the original date of shipment from Lumencor. Light Engines qualifying for warranty service must be verifiably delivering performance that is substantially at variance with the levels documented in the certificate of conformance. The light engine must also have been used and maintained under operating conditions consistent with the specifications given in Section 7, and observing all the Precautions and Warnings notified in Section 2. This warranty does not extend to light engines that have been subject to misuse, accident, tampering or improper installation. Accessories including (but not limited to) liquid light guides, optical fibers, collimators, cables and control consoles are not covered by the warranties attached to light engines. An extended warranty option is available; extended warranties must be purchased in advance of receipt of goods or within 60 days of the light engine delivery. Spectra FIA Light Engine Instruction Manual 12

SOLA SM II Light Engine Instruction Manual

SOLA SM II Light Engine Instruction Manual SOLA SM II Light Engine Instruction Manual Lumencor, Inc. Document Number 52-10036 www.lumencor.com Emissions Certifications This equipment has been tested and found to comply with the limits of EMC directive

More information

SOLA SM and SOLA SM 365 Light Engine Instruction Manual

SOLA SM and SOLA SM 365 Light Engine Instruction Manual SOLA SM and SOLA SM 365 Light Engine Instruction Manual Lumencor, Inc. Document Number 57-10003 www.lumencor.com Regulatory Models Lumencor utilizes regulatory model names for all certified and CE marked

More information

CELESTA Light Engine Instruction Manual

CELESTA Light Engine Instruction Manual CELESTA Light Engine Instruction Manual Lumencor, Inc. Document Number 57-10015, Rev. A www.lumencor.com Regulatory Models Lumencor utilizes regulatory model names for all certified and CE marked products.

More information

Lumination TM Volumetric Retrofit Kit

Lumination TM Volumetric Retrofit Kit GE Lighting Installation Guide Lumination TM Volumetric Retrofit Kit BEFORE YOU BEGIN Read these instructions completely and carefully. WARNING AVERTISSEMENT RISK OF FIRE OR ELECTRIC SHOCK Luminaire wiring

More information

Surface-Mounted NS Series Network Sensors without LCD

Surface-Mounted NS Series Network Sensors without LCD Surface-Mounted NS Series Network Sensors without LCD Installation Instructions NS-AHP7001-0, NS-AHN700x-x, NS-ATN700x-x, NS-ATP700x-x 24-10094- 17, Rev. P Part No. 24-10094-17, Rev. P Issued March 2016

More information

UV/White LED Light Source Kit

UV/White LED Light Source Kit UV/White LED Light Source Kit Preface Thank you for purchasing the ishot UV/White LED Light Source Kit which utilizes state-of-the-art solid-state illumination technology. The light source is a high output,

More information

System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules

System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules FANs 930, 125 Product/Technical Bulletin S350 Issue Date April 8, 2014 System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage s The S350A, S351A, and S352A Stage s are intended to be used

More information

Installation Instructions

Installation Instructions Installation Instructions 42" Island Vent Hood ZV1050 monogram.com 1 Safety Information BEFORE YOU BEGIN Read these instructions completely and carefully. Save these instructions for local inspector s

More information

GARAGE DOOR OPENER KIT

GARAGE DOOR OPENER KIT GARAGE DOOR OPENER KIT P/N 2883417 APPLICATION All 2018 and newer Slingshot models with Garage Door Opener By Homelink Kit PN 2881814 BEFORE YOU BEGIN Read these instructions and check to be sure all parts

More information

IMPORTANT: Read carefully before installation and retain for future reference. NOTE: Installation must be conducted by licensed electrician.

IMPORTANT: Read carefully before installation and retain for future reference. NOTE: Installation must be conducted by licensed electrician. INSTALLATION AND MAINTENANCE MANUAL StarPower Link LED Luminaire (Damp Location) Document No: 0077 Rev B Apr. 2015 IMPORTANT: Read carefully before installation and retain for future reference. NOTE: Installation

More information

Vertical Wallbox-Mounted or Surface-Mounted NS Series Network Sensors with LCD

Vertical Wallbox-Mounted or Surface-Mounted NS Series Network Sensors with LCD Vertical Wallbox-Mounted or Surface-Mounted NS Series Network Sensors with LCD NS-BHB700x-0, NS-BHR710x-0, NS-BPB700x-0, NS-BTB700x-x, NS-BTF700x-0, NS-BTV700x-0 Applications The vertical wallbox-mounted

More information

CD-Px Series Duct Mount CO 2 Transmitters

CD-Px Series Duct Mount CO 2 Transmitters CD-Px0-00-0 Series Duct Mount CO 2 Transmitters Product Bulletin CD-P00-00-0, CD-PR0-00-0 Code No. LIT-216525 Issued October 2016 Johnson Controls offers a complete line of carbon dioxide (CO 2 ) transmitters

More information

Smoke Control Listed LCM-OAVS VAV with HW Reheat, Two Venturi Air Valves (One Exhaust, One Supply) including BTU Compensation

Smoke Control Listed LCM-OAVS VAV with HW Reheat, Two Venturi Air Valves (One Exhaust, One Supply) including BTU Compensation Smoke Control Listed LCM-OAVS VAV with HW Reheat, Two Venturi Air Valves (One Exhaust, One Supply) including BTU Compensation Generic Controller I/O Layout. See Wiring Diagram for application specific

More information

Installation Instructions If you have questions, call 800-GE-CARES or visit our website at:

Installation Instructions If you have questions, call 800-GE-CARES or visit our website at: Installation Instructions If you have questions, call 800-GE-CARES or visit our website at: www.monogram.com 30" Convection Built-In Ovens Models: ZET1038 ZET1058 Monogram. We bring good things to life.

More information

User Guide. Luxxor. 35 LED Light Source Fax: Tremont Street, Rochester, New York gradientlens.

User Guide. Luxxor. 35 LED Light Source Fax: Tremont Street, Rochester, New York gradientlens. User Guide Luxxor 35 LED Light Source 207 Tremont Street, Rochester, New York 14608 800.536.0790 Fax: 585.235.6645 REV. 0116 gradientlens.com warnings & cautions Warnings & Cautions PORTABLE CAMERA Luxxor

More information

Draft - develop and review

Draft - develop and review MST Personnel Proximity Detection System Overview v. #.# Draft - develop and review System Overview 2.0 - Proximity Detection System.docx 1 January 2014 Page 1 of 18 The MST Proximity Solution The MST

More information

Siemens Automation Products Siemens AG All rights reserved A5E AB, 08/2017 1

Siemens Automation Products Siemens AG All rights reserved A5E AB, 08/2017 1 SIMATIC IPC277E Product Information General notes ATEX/IECEx - Additional Instructions for use in Gas Explosive Atmospheres (only valid for specific MLFBs - marked with IECEx/ATEX symbol on the nameplate

More information

Stopper Station Series Push Button Models SS2xx2, SS2xx5, SS2xx9

Stopper Station Series Push Button Models SS2xx2, SS2xx5, SS2xx9 Installation and Service Instructions Stopper Station Series Push Button Models SS2xx2, SS2xx5, SS2xx9 ADA Compliant NOTE For LTUL Models, Form C contacts on timer, Rated 30 VDC 3A, the enclosed timer

More information

Installation Instructions

Installation Instructions Installation Instructions (Cat. No. 1794-OB16) 3 7 1 English 2 6 4 5 Module Installation This module mounts on a 1794 terminal base unit. 1. Rotate keyswitch (1) on terminal base unit (2) clockwise to

More information

Wireless Outdoor Air Reset Adaptor PN:

Wireless Outdoor Air Reset Adaptor PN: Wireless Outdoor Air Reset Adaptor PN: 105767-01 Instruction Sheet APPLICATION The Wireless Outdoor Air Reset Adaptor, when connected to the Concert Boiler Control enables efficiency control functionality

More information

SZ-PIR04N ZigBee Motion Detector Installation Guide

SZ-PIR04N ZigBee Motion Detector Installation Guide SZ-PIR04N ZigBee Motion Detector Installation Guide SZ-PIR04N is a PIR (Passive Infrared) sensor, which can detect levels of infrared radiation from objects in its range of view. This Motion Detector is

More information

Stopper Station Series SS-2008 Push Button Pneumatic Timer Button

Stopper Station Series SS-2008 Push Button Pneumatic Timer Button Stopper Station Series SS-2008 Push Button Pneumatic Timer Button ADA for operation Pneumatic Timer Models SS-2008 Red SS-2108 Green SS-2208 Yellow SS-2308 White SS-2408 Blue ALL MODELS COME WITH A COLOR

More information

UNI 321. User s Guide

UNI 321. User s Guide UNI 321 User s Guide Ver 1.1 Dec. 2018 Contents Read Before Operating... 2 General Information... 3 User Interface... 3 Display... 3 Normal Operation... 3 Normal Mode Operation... 4 Turning the Unit On...

More information

Occupancy Sensor OCS 100W Setup Guide

Occupancy Sensor OCS 100W Setup Guide Sensor OCS 100W Setup Guide The OCS 100W is a wall-mounted occupancy sensor that incorporates ultrasonic (US) and passive infrared (PIR) into a dualtechnology sensor. The US sensor emits ultrasonic sound

More information

Tetra MAX. LED Lighting System. BEFORE YOU BEGIN Read these instructions completely and carefully. Installation Guide

Tetra MAX. LED Lighting System. BEFORE YOU BEGIN Read these instructions completely and carefully. Installation Guide Tetra MAX LED Lighting System Installation Guide Volt GEMXRD-W, GEMXHRD-W, GEMXGL-W, GEMXBL-W, GEMXYG-W BEFORE YOU BEGIN Read these instructions completely and carefully. RISK OF ELECTRIC SHOCK Turn power

More information

Location Requirements

Location Requirements 24-7701- 136, Rev. B FANs 216, 1628.3 Installation Instructions HH-6705 Issue Date 0316 TRUERH Series HH-6705 Duct Humidistat I nstallation IMPORTANT: Use this HH-6705 Series Duct Humidistat only as an

More information

ChemScan mini Analyzer for Low Ammonia Monitoring Installation, Operation and Maintenance Manual

ChemScan mini Analyzer for Low Ammonia Monitoring Installation, Operation and Maintenance Manual ChemScan mini Analyzer for Low Ammonia Monitoring Installation, Operation and Maintenance Manual asaanalytics.com ChemScan mini Low Ammonia Analyzer O&M Manual - Rev 223K TABLE OF CONTENTS ANALYZER DESCRIPTION

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Document 474741 Model XCR and XIR Ceiling Exhaust and Inline Fans Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting

More information

1100D Wireless Receiver

1100D Wireless Receiver 00D Wireless Receiver INSTALLATION GUIDE Description The 00D Wireless Receiver provides up to 32 wireless zones for XT30/XT50 Series panels with Version 02 or higher. The 00D provides two-way, supervised

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Document 474680 Model SP and CSP Ceiling Exhaust and Inline Fans Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting

More information

200i User s information manual

200i User s information manual M2i-UM-1 WARNING: If the information in this manual is not followed exactly, a fire or explosion may result, causing property damage, personal injury or loss of life. Cast iron condensing boiler 200i User

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Document 474680 Model SP Model CSP Ceiling Exhaust and Inline Fans Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting

More information

Installation Instructions If you have questions, call or visit our website at:

Installation Instructions If you have questions, call or visit our website at: Installation Instructions If you have questions, call 800.626.2000 or visit our website at: www.monogram.com Wine Reserve ZDWT240 and Beverage Center ZDBT240 Design Guide With Installation Instructions

More information

SkyNEST WASP Portable Kit, Smart Receiver and SCADA Gateway with Solar Panel USER MANUAL

SkyNEST WASP Portable Kit, Smart Receiver and SCADA Gateway with Solar Panel USER MANUAL SkyNEST WASP Portable Kit, Smart Receiver and SCADA Gateway with Solar Panel USER MANUAL VERSION 1.1 22/08/2018 VISIT OUR WEBSITE FOR MORE INFORMATION. WWW.BOSSPAC.COM WASP is a registered trademark owned

More information

Lumination TM Controls Accessory LPL Series Controller Box

Lumination TM Controls Accessory LPL Series Controller Box Installation Guide Lumination TM Controls Accessory LPL Series Controller Box BEFORE YOU BEGIN Read these instructions completely and carefully. RISK OF FIRE OR ELECTRIC SHOCK Turn power off before inspection,

More information

PEDESTAL INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION DU PIÉDESTAL

PEDESTAL INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION DU PIÉDESTAL PEDESTAL INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION DU PIÉDESTAL Table of Contents PEDESTAL SAFETY... 1 INSTALLATION REQUIREMENTS... 2 Tools and Parts... 2 Location Requirements... 2 Before

More information

Installation Instructions

Installation Instructions Design Guide with Installation Instructions Wine Reserve ZDWT240 and Beverage Center ZDBT240 monogram.com Safety Information BEFORE YOU BEGIN: Read these instructions completely and carefully. IMPORTANT

More information

P266 Series Single-Phase Condenser Fan Speed Control

P266 Series Single-Phase Condenser Fan Speed Control P266 Series Single-Phase Condenser Fan Speed Control Product Bulletin P266xxx-x Code No. LIT-12011534 Issued June 24, 2009 The P266 Single-Phase Condenser Fan Speed Control is a cost-effective, weather-resistant,

More information

Operation & Care Instructions Save For Future Reference ABOUT THE MACHINE

Operation & Care Instructions Save For Future Reference ABOUT THE MACHINE Operation & Care Instructions Save For Future Reference Model Euro 930 Hepa vac Dry Canister HEPA Vacuum Cleaner This product is a high performance dry canister vacuum for commercial/industrial use. All

More information

PH:

PH: ALL MODELS: THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. CE PRODUIT

More information

AB Parts. ControlNet Coax Tap. Installation Instructions. (Cat. Nos TPR, -TPS, -TPYR, -TPYS) What s in This Document

AB Parts. ControlNet Coax Tap. Installation Instructions. (Cat. Nos TPR, -TPS, -TPYR, -TPYS) What s in This Document Installation Instructions ControlNet Coax Tap (Cat. Nos. 1786-TPR, -TPS, -TPYR, -TPYS) What s in This Document Use this document as a guide when installing a ControlNet coax tap. To: See Page: verify package

More information

Aquatron 4, 8, /95 Form Number Instructions For Use. Advance Models , , , ,

Aquatron 4, 8, /95 Form Number Instructions For Use. Advance Models , , , , Aquatron 4, 8, 11 Instructions For Use Advance Models 56250191, 56250192, 56250193, 56250205, 56250207 10/95 Form Number 56041318 TABLE OF CONTENTS Page Introduction...2 Parts and Service...2 Nameplate...2

More information

Instruction Manual Advanced Mini Block Heaters Advanced Mini Block Heater with Heated Lid

Instruction Manual Advanced Mini Block Heaters Advanced Mini Block Heater with Heated Lid Instruction Manual Advanced Mini Block Heaters Advanced Mini Block Heater with Heated Lid Table of Contents Package Contents.............. 1 Warranty.............. 1 Installation.............. 2 Maintenance

More information

EL-TSTAT Owner s Manual

EL-TSTAT Owner s Manual EL-TSTAT-8810 Owner s Manual TABLE OF CONTENTS TABLE OF CONTENTS EL-TSTAT-8810 ABOUT YOUR NEW THERMOSTAT Thermostat features 3 Controls & display overview 4 WI-FI SETUP 5-6 OPERATION & PROGRAMMING Select

More information

Product ID. General. TE CONNECTIVITY SENSORS /// EXxxHyy Ex-Atex & NA 09/2017 Page 1

Product ID. General. TE CONNECTIVITY SENSORS /// EXxxHyy Ex-Atex & NA 09/2017 Page 1 s for use in explosive atmospheres Europe ATEX II 2 G and North America ClI, Div 1 & 2 and Cl II, Div 1 & 2 and Cl III and North America Cl I, Zone 1 Product ID Type # Product # Drawing # EX34H 385Z-05637

More information

ADT. Pulse 2017ADT LLC

ADT. Pulse 2017ADT LLC ADT Pulse Interactive Solutions DBC835 Wirelesss HD Doorbell Cameraa Quick Installation Guide Property of ADT, LLC. Information accurate as of published date and is provided as is without warranty of any

More information

9 W, 15 W and 25 W Industrial Fiber Laser Systems IFL Series

9 W, 15 W and 25 W Industrial Fiber Laser Systems IFL Series COMMERCIAL LASERS 9 W, 15 W and 25 W Industrial Fiber Laser Systems IFL Series Key Features Diffraction-limited light delivered through fiber termination module Single transverse mode, collimated beam

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS with Design Guide Double-Drawer Built-In Refrigerator Monogram.com Safety Information BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT Save these instructions

More information

Technical Manual for the Strobe - SM87 HXB

Technical Manual for the Strobe - SM87 HXB Technical Manual for the Strobe - SM87 HXB Please note that every care has been taken to ensure the accuracy of our technical manual. We do not, however, accept responsibility for damage, loss or expense

More information

QUICK START GUIDE. Lono, LLC 686 East 110 South, Suite 102 American Fork, UT 84003

QUICK START GUIDE. Lono, LLC 686 East 110 South, Suite 102 American Fork, UT 84003 QUICK START GUIDE Lono, LLC 686 East 110 South, Suite 102 American Fork, UT 84003 Welcome. This guide will help you install your Lono controller. For additional information, check out our installation

More information

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE ZR Series Commercial Specification Troffers with Emergency Driver Includes: ZR14, ZR22 and ZR24 IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed

More information

POINT I/O Field Potential Distributor Module

POINT I/O Field Potential Distributor Module Installation Instructions POINT I/O Field Potential Distributor Module Catalog Number 1734-FPD, Series B Inside... For See Page Important User Information 2 Environment and Enclosure 3 Preventing Electrostatic

More information

PH:

PH: ALL MODELS: THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. CE PRODUIT

More information

PDD-FT-3. Fire Panel Interface With EOL Trigger. Installation and Specifications Manual

PDD-FT-3. Fire Panel Interface With EOL Trigger. Installation and Specifications Manual Installation -3-3 Fire Panel Interface With EOL Trigger Installation and Specifications Manual ISPSFPD-3 PCN16045 R12/17GR 2017 Rutherford Controls Int l dormakaba Group www.rutherfordcontrols.com Phone:

More information

OTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL

OTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL OTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL Phone: (209) 586-022 (800) 545-022 Fax: (209) 586-026 E-Mail: salessupport@olsontech.com www.olsontech.com OTEB-CO-B (No SNMP) Rev. X7 /7/200 SAFETY WARNINGS

More information

Compact I/O End Caps/Terminators

Compact I/O End Caps/Terminators Installation Instructions Original Instructions Compact I/O End Caps/Terminators Catalog Numbers 1769-ECL, 1769-ECR, 1769-ECRK Topic Page Summary of Changes 2 1769-ECL Left End Cap 5 1769-ECL Dimensions

More information

Instruction Manual. Counter Showcase Models HNC-120BA-L/R-SL HNC-150BA-L/R-SL HNC-180BA-L/R-SL HNC-210BA-L/R-SL. hoshizakiamerica.

Instruction Manual. Counter Showcase Models HNC-120BA-L/R-SL HNC-150BA-L/R-SL HNC-180BA-L/R-SL HNC-210BA-L/R-SL. hoshizakiamerica. Instruction Manual Counter Showcase Models HNC-120BA-L/R-SL HNC-150BA-L/R-SL HNC-180BA-L/R-SL HNC-210BA-L/R-SL hoshizakiamerica.com Issued: 5-1-2017 WARNING Only qualifi ed service technicians should install

More information

CAUTION CAUTION WARNING. Vulcan RT Heater With Remote Temperature Controller

CAUTION CAUTION WARNING. Vulcan RT Heater With Remote Temperature Controller Congratulations for choosing VULCAN RT electric heating system. It is loaded with 37,000 BTU s (11KW) of heat power, 475 CFM of air flow and precise temperature controls. It features individually controlled

More information

3kW 6kW, QUBE Fiber Lasers

3kW 6kW, QUBE Fiber Lasers 3kW 6kW, QUBE Fiber Lasers CONTENTS 1.1 SCOPE 2 1.2 OPTICAL SPECIFICATION 2 1.3 BEAM DELIVERY FIBER SPECIFICATION 3 1.4 SHARE UNITS 3 1.5 ALIGNMENT LASER 3 1.6 POWER DISTRIBUTION 4 1.7 WATER COOLING REQUIREMENTS

More information

INSTALLATION INSTRUCTION In-Ground

INSTALLATION INSTRUCTION In-Ground SAFETY INSTRUCTION IMPORTANT: NEVER attempt any work without shutting off the electricity. Read all instructions before installing. System is intended for installation by a qualified electrician in accordance

More information

Remote Notification System Instruction Manual

Remote Notification System Instruction Manual Remote Notification System Instruction Manual Welcome to your new Victor Kill-@lert Remote Notification System This guide will familiarize you with all of the features and functionality of the Victor Kill-@lert

More information

ETG-LRP Series. 4 LED Remote Phosphor Linear Low Bay and High Bay Lighting. Figure 1-2 tube LRP with reflector shown

ETG-LRP Series. 4 LED Remote Phosphor Linear Low Bay and High Bay Lighting. Figure 1-2 tube LRP with reflector shown ETG-LRP Series 4 LED Remote Phosphor Linear Low Bay and High Bay Lighting Figure 1-2 tube LRP with reflector shown 1. INTRODUCTION Advanced LED Remote Phosphor (LRP) lighting provides superior efficacy,

More information

Atomic Digital Office Clock

Atomic Digital Office Clock Atomic Digital Office Clock MONTH DATE For online video support: http://bit.ly/laxtechtalk Instructional Manual Model: 513-1419BL-WA DC:112516 Protected under U.S. Patents: 5,978,738 6,076,044 RE43903

More information

ASPEC Positive Pressure Manifold. User's Guide

ASPEC Positive Pressure Manifold. User's Guide ASPEC Positive Pressure Manifold User's Guide This Page Is Intentionally Left Blank Gilson, Inc. All rights reserved. All product and/or company names are trademarks of their respective holders. Use of

More information

G4 Pulsed Fiber Laser

G4 Pulsed Fiber Laser G4 Pulsed Fiber Laser OEM Safety and System Integration Manual Module types C1 and C2 Module type C1 - fitted with IBeam1 delivery optic Module type C2 - fitted with IBeam2 delivery optic 1 1 Preface Definition

More information

Intelligent Home Solutions Quick Start Guide. Monitor your home from anywhere with your smartphone

Intelligent Home Solutions Quick Start Guide. Monitor your home from anywhere with your smartphone Model: isb01 Intelligent Home Solutions Quick Start Guide Wi-Fi MOTION SENSOR Monitor your home from anywhere with your smartphone WHAT YOU LL NEED WiFi network transmitting at 2.4GHz; WPA2 security type

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Document 453284 Model BCF Centrifugal Cabinet Fans Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble,

More information

STRUCTURED LIGHT. LED Strobe Indicator ON = Light Active Green Indicator LED

STRUCTURED LIGHT. LED Strobe Indicator ON = Light Active Green Indicator LED SXP30 Series STRUCTURED LIGHT Projector product introduction The SXP30 Series Projector Light offers the most intense projected pattern offered from an LED. The 9mm² die size emits 9x the intensity as

More information

HP Power Distribution Unit with Power Monitoring (Models S124 and S132) User Guide

HP Power Distribution Unit with Power Monitoring (Models S124 and S132) User Guide HP Power Distribution Unit with Power Monitoring (Models S124 and S132) User Guide March 2006 (First Edition) Part Number 413611-001 Copyright 2006 Hewlett-Packard Development Company, L.P. The information

More information

Instruction Manual Standard Dry Block Heaters Advanced Dry Block Heaters U L

Instruction Manual Standard Dry Block Heaters Advanced Dry Block Heaters U L Instruction Manual Standard Dry Block Heaters Advanced Dry Block Heaters 1 U L Table of Contents Package Contents.............. 1 Warranty.............. 1 Installation.............. 2 Maintenance & Servicing..............

More information

Yale Real Living Key Free Push Button Deadbolt B1 with Installation and Programming Instructions

Yale Real Living Key Free Push Button Deadbolt B1 with Installation and Programming Instructions Yale Real Living Key Free Push Button Deadbolt B1 with Installation and Programming Instructions L WAVE x3 #8-32 x 5/16" Machine screws x4 #7 wood & #8-32 machine x 20mm Combination screws x2 M6x47mm Long

More information

FES - Series Portable Electric Heaters

FES - Series Portable Electric Heaters FOSTORIA INDUSTRIES 114 Roscoe Fitz Road Gray, TN 37615 Phone: 800-495-4525 Fax: 419-435-0842 www.fostoriaindustries.com Division of TPI Corporation YES - Series Suspended Electric Heaters FES - Series

More information

INTRODUCTION. Industry Canada: Canadian ID: 6982A-YRHCPZW0 (Z-Wave); 6982A-YRHCPZB0 (Zigbee)

INTRODUCTION. Industry Canada: Canadian ID: 6982A-YRHCPZW0 (Z-Wave); 6982A-YRHCPZB0 (Zigbee) Industry Canada: Canadian ID: 6982A-YRHCPZW0 (Z-Wave); 6982A-YRHCPZB0 (Zigbee) This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Operation

More information

1100X Wireless Receivers

1100X Wireless Receivers 00X Wireless Receivers INSTALLATION GUIDE Description The 00X Wireless Receiver is compatible with all DMP wireless devices. The receiver provides two-way, supervised communication using 900 MHz frequency

More information

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter PD685 Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter Actual Size Digits C US Intrinsically Safe 3½ Digits LARGE DISPLAY NEMA 4, Type 4X, IP67 Loop-Powered Field-Mount Process Meter 4-20 ma

More information

Refrigerated Incubator Model and Operating Instructions

Refrigerated Incubator Model and Operating Instructions Refrigerated Incubator Model 165000 and 165000-2 Operating Instructions N2400379 - Rev. 1 08May2018 1 Contents 1. SAFETY...3 1.1. EMF INTERFERENCE...4 1. PRODUCT INFORMATION...5 1.1 INTRODUCTION...5 2.

More information

Installation Instructions If you have questions, call 800-GE-CARES or visit our website at:

Installation Instructions If you have questions, call 800-GE-CARES or visit our website at: Installation Instructions If you have questions, call 800-GE-CARES or visit our website at: www.monogram.com Island Vent Hoods Models: ZV42I ZV54I Monogram. BEFORE YOU BEGIN Read these instructions completely

More information

ShockLink. Important Product Information.

ShockLink. Important Product Information. EN ShockLink Important Product Information www.laerdal.com English ShockLink Important Information Warnings and Cautions A Warning states a condition, hazard, or unsafe practice that can result in serious

More information

TEC3000 Series Stand-Alone and Field-Selectable BACnet MS/TP or N2 Networked Thermostat Controllers

TEC3000 Series Stand-Alone and Field-Selectable BACnet MS/TP or N2 Networked Thermostat Controllers TEC3000 Series Stand-Alone and Field-Selectable BACnet MS/TP or N2 Networked Thermostat Controllers TEC331x-00-000, TEC332x-00-000, TEC333x-00-000, TEC361x-00-000, TEC362x-00-000, TEC363x-00-000 Code.

More information

INSTALLATION INSTRUCTION In-Ground Color Changing

INSTALLATION INSTRUCTION In-Ground Color Changing SAFETY INSTRUCTION IMPORTANT: NEVER attempt any work without shutting off the electricity. Read all instructions before installing. System is intended for installation by a qualified electrician in accordance

More information

safety & regulatory information

safety & regulatory information safety & regulatory information Document Part Number: 338610-001 Sixth Edition June 2006 This guide provides safety and regulatory information that is compliant with U.S., Canadian, and International regulations.

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Document 453284 Centrifugal Cabinet Fans Model BCF Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble,

More information

Certificate of Compliance

Certificate of Compliance FF0002 Certificate of Compliance Certificate: 70044220 Issued to: Cascade Technologies Limited Glendevon House Castle Business Park Stirling FK9 4TZ UK Attention: Mr. Marcus Douglas The products listed

More information

S541.RF 4G Product Guide

S541.RF 4G Product Guide S541.RF 4G Product Guide Table of Contents Table of Contents... Page 1 Overview and General Concept... Page 2 Application... Page 2 Features... Page 3 Specifications... Page 3 Network Topology... Page

More information

MAXLITE RKT LED Retrofit Kit

MAXLITE RKT LED Retrofit Kit Operating Instructions MAXLITE RKT LED Retrofit Kit Description and Intended Use The RKT LED Retrofit Kit is a high performance LED Fixture upgrade kit designed to replace the original components inside

More information

High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305

High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305 High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305 The new high-power Q305 laser is an expansion of the existing Q-Series that provides a solution for demanding applications requiring faster throughput.

More information

MW Pince courant de fuite Leakage current Clampmeter. Notice d utilisation User s Manual M3950M00

MW Pince courant de fuite Leakage current Clampmeter. Notice d utilisation User s Manual M3950M00 MW 3950 Pince courant de fuite Leakage current Clampmeter Notice d utilisation User s Manual M3950M00 Safety Information To ensure safe operation and service of the Tester, follow these instructions. Failure

More information

Pet Immune SAW PIR Motion Sensor

Pet Immune SAW PIR Motion Sensor PET Immune SAW PIR Motion Sensors Installation Sheet Description This is the Installation Sheet for SAW PIR and PET Immune Motion Sensors. See Table 1. Table 1: Motion Sensors 60-807-95R 60-807-01-95R

More information

SEE DISCLAIMER ON REVERSE

SEE DISCLAIMER ON REVERSE BOLTEK CORPORATION Lightning Detection GSM-1 Text Message Notification for EFM-100C Electric Field Monitor User Guide SEE DISCLAIMER ON REVERSE BOLTEK LIGHTNING DETECTION GSM-1 Text Message Alert Dialer

More information

Low Voltage Fan Coil Thermostat ST101ZB. Quick Start Guide. For other language versions, please visit

Low Voltage Fan Coil Thermostat ST101ZB. Quick Start Guide. For other language versions, please visit Low Voltage Fan Coil Thermostat ST101ZB Quick Start Guide For other language versions, please visit www.salusinc.com Notices Please read these instructions carefully before installing and using the Low

More information

Instruction Manual PC55O. With PC5OORK Keypad

Instruction Manual PC55O. With PC5OORK Keypad Instruction Manual PC55O With PC5OORK Keypad Industry Canada Notice NOTICE: The Industry Canada label identifies certified equipment. This certification means that the equipment meets certain telecommunications

More information

Throughbeam photoelectric sensor for the detection of aqueous liquids. Dimensioned drawing

Throughbeam photoelectric sensor for the detection of aqueous liquids. Dimensioned drawing Technical data and description LS 55 Throughbeam photoelectric sensor for the detection of aqueous liquids Dimensioned drawing en 03-2016/11 50127872-02 350 Hz 0 80m 10-30 V DC We reserve the right to

More information

Alpine CONDENSING HIGH EFFICIENCY GAS-FIRED HOT WATER BOILER

Alpine CONDENSING HIGH EFFICIENCY GAS-FIRED HOT WATER BOILER USER'S INFORMATION MANUAL Alpine CONDENSING HIGH EFFICIENCY GAS-FIRED HOT WATER BOILER If the information in this manual is not followed exactly, a fire or explosion may result causing property damage,

More information

Instruction Manual. Hotplate-Stirrers

Instruction Manual. Hotplate-Stirrers Instruction Manual Advanced Round Top Hotplate-Stirrers Table of Contents Package Contents............ 1 Warranty............ 1 Installation............ 2 Maintenance & Servicing............ 2 Intended

More information

Instruction Manual Round Top Hotplate-Stirrers. Advanced Unit

Instruction Manual Round Top Hotplate-Stirrers. Advanced Unit Instruction Manual Round Top Hotplate-Stirrers Advanced Unit TABLE OF CONTENTS Package Contents............... 1 Warranty............... 1 Installation............... 2 Maintenance & Servicing...............

More information

Certification Supplement Manual

Certification Supplement Manual PROCESS ANALYSERS SERVOTOUGH Oxy Gas Analyser Certification Supplement Manual Part Number: 01910008B Revision: 9 Language: UK English This page intentionally blank SERVOTOUGH Oxy Certification Supplement

More information

Optical laser distance sensors. Dimensioned drawing

Optical laser distance sensors. Dimensioned drawing Optical laser distance sensors Dimensioned drawing en 08-2014/07 50103924-02 150 2300mm We reserve the right to make changes DS_ODSL96KV662300_en_50103924_02.fm Reflection-independent distance information

More information

Ultraviolet Disinfection Systems

Ultraviolet Disinfection Systems Systems tested and certified by NSF International against NSF/ ANSI Standard 55 for disinfection performance, Class A. Ultraviolet Disinfection Systems WHO IS VIQUA - a Trojan Technologies Company VIQUA

More information

Mason Air AS8800/ AS8800-RR/AS Instruction Manual. Low air loss/alternating pressure mattress

Mason Air AS8800/ AS8800-RR/AS Instruction Manual. Low air loss/alternating pressure mattress Mason Air AS8800/ AS8800-RR/AS8800-84 Low air loss/alternating pressure mattress Instruction Manual Drive Medical 99 Seaview Boulevard Port Washington, NY 11050 Toll Free: 877-224-0946 Local: 516-998-4600

More information

Illuminated Stopper Station Push Button

Illuminated Stopper Station Push Button Illuminated Stopper Station Push Button Model SS2xx6 Rely on STI Dimensions 4.880 in [123.95 mm] 3.218 in [81.74 mm] 1.625 in [41.28 mm].875 in [22.23 mm] Switch Rating 2 momentary independent Form C contacts,

More information