Card SN Relay V23030
|
|
- Benjamin Barnett
- 5 years ago
- Views:
Transcription
1 Card SN Relay V23030 n n Low profile, therefore particularly suited for flat pack components grouping For relays with or 2 form C (CO) contacts: - creepage and clearance distances between contacts and frame >5mm or >0mm (depending on the relay version) - dielectric strength between contacts and frame 4kVrms or 6kVrms Typical applications measuring and control systems, alarm and security equipment, road traffic and railway signaling systems Contact Data A04 A06 A204 A206 Contact arrangement 4 form C, 6 form C, 4 form C, 6 form C, (4 CO) (6 CO) (4 CO) (6 CO) Max. switching voltage VAC 250VAC 36VAC 36VAC Limiting continuous current 50 C ambient 75 C ambient Limiting making/breaking current 3A) 3A) Contact material Ag, Ag, Gold F2) Gold F2) Au-flashed Au-flashed Contact style bifurcated contacts Frequency of operation, without load max. 30 operations/s Operate / release time approx. 8/2ms Max. DC breaking capacity (contacts Ag, gold flashed) Curve : arc extinguished within contact transit period (limit curve I) Curve 2: safe breaking, erc extinguished (limit curve II) Contact Data (continued) Mechanical endurance aaprox. 08 operations ) The current of 3 A for max 4s at 0% on-time. 2) Gold F on request only 3) Self inductance in accordance with IEC Coil Data Magnetic system Coil voltage range Max. coil temperature Thermal resistance neutral, monostable 5 to 60 0 C 35K/W Coil versions, monostable Coil Rated Operate Limiting Coil Rated coil code voltage voltage Voltage resistance power 4/6 pole Ω±0%4) mw / / / / / ) / ) 878 4) Coil resistance ±5% All figures are given for coil without pre-energization, at ambient temperature +23 C The operating voltage limits UI and UII depend on temperature according to the following formula: UI tamb = ki*ui 20 C, UII tu = kii*uii 20 C; tamb = ambient temperature, UI tamb = minimum voltage at ambient temperature, UII tamb = maximum voltage at ambient temperature, ki and kii are factors. tamb 20 C 30 C 40 C 50 C 60 C 70 C ki kii Insulation Data Electrical endurance Type Load 2.4A, 24, resistive 3A, 24, resistive.35a, 30, resistive 0.85A, 40, resistive 0.36A, 60, resistive 0.2, 0, rersitive 2.4A, 24, resistive+00μh3) 0.6A, 60, resistive+00μh3) 0.24A, 0, resistive+00μh3) , Rev Tyco Electronics Corporation, Operations appr. x06 appr. 0.3x06 appr. 6x06 appr. 2x07 appr. 8x07 appr. 0x07 appr. x06 appr. 0x06 40x06 according to IEC 680- and to be used Initial dielectric strength between coil and frame between contact and contact between contact and frame between contact and coil 500Vrms 000Vrms 000Vrms 000Vrms
2 Other Data Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content refer to the Product Compliance Support Center at /customersupport/rohssupportcenter Ambient temperature -40 to +70 C Category of environmental protection IEC 680 RT I - dust protected, RT III - immersion cleanable Degree of protection, IEC IP30, IP67 Terminal type PCB-THT Weight V23030-Axxx approx. 2g V23030-Cxxx approx. 30g V23030-Hxxx approx. 25g V23030-Jxxx approx. 30g Ultrasonic cleaning not recommended Packaging unit 5 pcs. PCB layout / terminal assignment Bottom view on solder pins 4 form C (4 CO) contacts V23030-Axxxx-xx04 V23030-Hxxxx-xx04 6 form C (6 CO) contacts V23030-Axxxx-xx04 V23030-Hxxxx-xx04 Hole M required only for relays with earth connection , Rev Tyco Electronics Corporation, according to IEC 680- and to be used Hole M required only for relays with earth connection.
3 Dimensions V23030-Axxx, 4 form C (4 CO) contacts, dust protected V23030-Hxxx, 4 form C (4 CO) contacts, immersion cleanable V23030-Cxxx, 6 form C (6 CO) contacts, dust protected V23030-Jxxx, 6 form C (6 CO) contacts, immersion cleanable , Rev Tyco Electronics Corporation, according to IEC 680- and to be used 3
4 Product code structure Typical product code V A 02 -A 04 Type V23030 Card SN Relay Contact arrangement A 4 form C, 4 CO, dust proof C 6 form C, 6 CO, dust proof H 4 form C, 4 CO, immersion cleanable J 6 form C, 6 CO, immersion cleanable Earth connection Without earth connection 2 With earth connection Coils Coil code: please refer to coil versions table Contact material A Silver, gold flashed A2 Gold F Contact arrangement 04 4 form C, 4 CO 06 6 form C, 6 CO Other types on request Product code Version Coil Arrangement Enclosure Part number V23030-Axxx, 4 pole, without earth connection, dust protected V23030-A07-A04 4 pole, without earth conn. 2 4 form C (4 CO) Dust protected V23030-A02-A04 4 pole, without earth conn form C (4 CO) Dust protected V23030-A026-A04 4 pole, without earth conn form C (4 CO) Dust protected V23030-A2xxx, 4 pole, with earth connection, dust protected V23030-A202-A04 4 pole, with earth conn. 6 4 form C (4 CO) Dust protected V23030-A207-A04 4 pole, with earth conn. 2 4 form C (4 CO) Dust protected V23030-A207-A204 4 pole, with earth conn. 2 4 form C (4 CO) Dust protected V23030-A202-A04 4 pole, with earth conn form C (4 CO) Dust protected V23030-A2026-A04 4 pole, with earth conn form C (4 CO) Dust protected V23030-A204-A04 4 pole, with earth conn form C (4 CO) Dust protected V23030-Cxxx, 6 pole, without earth connection, dust protected V23030-C07-A04 6 pole, without earth conn. 2 6 form C (6 CO) Dust protected V23030-C02-A04 6 pole, without earth conn form C (6 CO) Dust protected V23030-C02-A204 6 pole, without earth conn form C (6 CO) Dust protected V23030-C026-A04 6 pole, without earth conn form C (6 CO) Dust protected V23030-C2xxx, 6 pole, with earth connection, dust protected V23030-C202-A04 6 pole, with earth conn. 6 6 form C (6 CO) Dust protected V23030-C207-A04 6 pole, with earth conn. 2 6 form C (6 CO) Dust protected V23030-C207-A204 6 pole, with earth conn. 2 6 form C (6 CO) Dust protected V23030-C202-A04 6 pole, with earth conn form C (6 CO) Dust protected V23030-C204-A04 6 pole, with earth conn form C (6 CO) Dust protected , Rev Tyco Electronics Corporation, according to IEC 680- and to be used Datasheets, product data, Definitions section, application notes and all specifications
5 Partner in Electronic Components & Supply Chain Solutions The Netherlands Elektrostraat 7 NL-7483 PG Haaksbergen Tel: +3 (0) Fax: +3 (0) nl@texim-europe.com Denmark Sdr. Jagtvej 2 DK-2970 Hørsholm Tel: Fax: nordic@texim-europe.com Belgium Gentsesteenweg 54-C22 Chaussée de Gand 54-C22 B-082 Brussel / Bruxelles Tel: +32 (0) Fax: +32 (0) belgium@texim-europe.com United Kingdom St. Mary s House, Church Lane Carlton Le Moorland Lincoln LN5 9HS Tel: +44 (0) Fax: +44 (0) uk@texim-europe.com Germany Bahnhofstrasse 92 D-2545 Quickborn Tel: +49 (0) Fax: +49 (0) germany@texim-europe.com Germany Martin-Kollar-Strasse 9 D-8829 München Tel: +49 (0) Fax: +49 (0) germany@texim-europe.com Austria Warwitzstrasse 9 A-5020 Salzburg Tel: +43 (0) Fax: +43 (0) austria@texim-europe.com Texim Europe B.V. Elektrostraat 7 NL-7483 PG Haaksbergen Tel: +3 (0) info@texim-europe.com
Proximity SWITCHES. Inductive Sensors. Capacitive Sensors. Photo Electric Sensors. N1DR_ B Series. N1DE_ S Series. N1DR_ B_W Series.
Proximity SWITCHES N1DR_ B Series N1DE_ S Series Food and Beverage Automotive Industry Inductive Sensors N1DR_ B_W Series N1DR_G Series Machine & Equipment Warehouse & Distribution N1KR_N Series Capacitive
More informationIntroducing Inverted SMT Thru Board Connector
Introducing Inverted SMT Thru Inverted SMT Thru KEY FEATURES Available in 2 through 6 positions Eliminates wire dress management issues with discreet wire leads around the surface of the LED pc board Accepts
More informationIES308. Introduction: Packing List: Features: 8-port Unmanaged Industrial Ethernet Switch Hardware Installation Guide
IES308 8-port Unmanaged Industrial Ethernet Switch Hardware Installation Guide Introduction: IES308 series are a smart plug-and-play industrial Ethernet switch, which can provide economical solution for
More informationAXICOM Telecom-, Signal and RF Relays. Cradle Relay Accessories and Mounting Nov. 07 Rev. C ECOC: JM10
Cradle Relay Accessories and Mounting 108-98016 Nov. 07 Rev. C ECOC: JM10 Disclaimer While Tyco Electronics has made every reasonable effort to ensure the accuracy of the information in this datasheet,
More informationEN: This Datasheet is presented by the m anufacturer. Please v isit our website for pricing and availability at ore.hu.
EN: This Datasheet is presented by the m anufacturer. Please v isit our website for pricing and availability at www.hest ore.hu. PE bistable - small, strong, smart Miniature PCB Relay PE bistable 1pole
More informationPCB Relays Single Relays
Features Small power relay Limiting continuous current 30 A Minimal weight Low noise operation Wave (THT) and reflow (THR/pin-in-paste) solderable versions For twin version refer to Double Micro Relay
More informationCII FCAC-150 Series Relay
Introducing CII Series Relay 50 Amps, 1PST/NO (DM) CII Series Relay 50 Amps, 1PST/NO (DM) with 1PDT Auxiliary Contacts KEY FEATURES Non-latching relay Balanced force design Corrosion protected metal enclosure
More informationDatasheet - MZM 100 ST2-1P2PWREM-A
30.05.2015-14:45:08h Datasheet - MZM 100 ST2-1P2PWREM-A Solenoid interlock / MZM 100 Preferred typ Guard locking monitored Automatic latching Solenoid interlocks (for the protection of man) with innovating
More informationDatasheet - MZM 100 ST-SD2PREM-A
19.03.2014-10:31:42h Datasheet - MZM 100 ST-SD2PREM-A Solenoid interlock / MZM 100 Preferred typ Guard locking monitored Automatic latching Solenoid interlocks (for the protection of man) with innovating
More informationDatasheet - MZM 100 B ST2-SD2PREM-A
30.05.2015-14:46:12h Datasheet - MZM 100 B ST2-SD2PREM-A Solenoid interlock / MZM 100 Preferred typ Actuator monitored Automatic latching Solenoid interlocks (for the protection of man) with innovating
More informationIEC UC3 compliant (short current 3,000 A) 1 Form A 120A power latching relays
To Be Discontinued IEC62055-31 UC3 compliant (short current 3,000 A) 1 Form A 120A power latching relays DZ RELAYS (ADZ) New New Horizontal terminal type FEATURES 1. IEC62055-31 UC3 compliant (short current
More informationUL TEST REPORT AND PROCEDURE
Issue Date: 2010-12-01 Page 1 of 16 Report Reference # E252373-A31-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: Rating: UL 60950-1, 2nd Edition, 2014-10-14 (Information
More informationOilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor
Labkotec UK Ltd Adminicle House 1 Lumb Lane Audenshaw Manchester M34 5WH GREAT BRITAIN Tel: 0844 3350 477 Fax: 0161 4281 179 E-mail: info@labkotec.co.uk 10.8.2012 Internet: www.labkotec.co.uk 1/13 OilSET-1000
More informationPT - the new Generation
PT - the new Generation The new standard...pt For panel applications... With a switching current of 6 A, the 4 pole PT offers 20% more switching power than its competitors. The 3 pole 10 A version has
More informationAnnunciator Relay MR 11 and MRE 11 MR 21 and MRE 21. Automation Equipment. Power Station Control Systems. Control Room Technology
Annunciator Relay MR 11 and MRE 11 MR 21 and MRE 21 Power Station Control Systems Power Distribution Control Systems Control Room Technology Automation Equipment The products described in this brochure
More informationPRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector
PRODUCT SPECIFICATION 108-115057 29OCT13 Rev. A1 0.5mm Fine Stacking Hermaphroditic Type BTB Connector 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for 0.5mm
More informationCat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE
Cat. N STOP & GO automatic resetting 87045 LIMOGES Cedex - FRANCE Telephone : + 33 5 55 06 87 87 Fax: + 33 5 55 06 88 88 Cat. N (s) : 4 062 88 / 4 062 89 CONTENTS PAGE 1. Description - Use... 1 2. Product
More informationTILT SENSOR SWITCH. Item No. RBS Description Ball-Contact Version 13 Page 1 of 7 Publish Date May 29, 2018
Page 1 of 7 Publish Date May 29, 2018 FUNCTION Rotation detection at 45 in vertical position APPLICATIONS 1 Rotation Detection for kinds of monitor/device 2 Toys / Entertainment devices FEATURES 1 Suitable
More informationTCS5JBL & TCS5JBLA. Low-Voltage Top-Up Switch
3P Technik TCS5JBL & TCS5JBLA Low-Voltage Top-Up Switch Installation and Operation Manual 3P TCS5JBL/TCS5JBLA Page 1 11/09/16 Table of Contents Description Of Operation...2 Installation...2 Safety Precautions...2
More informationC Note! LGI16... Burner Controls. Building Technologies
7 786 Burner Controls LGI16... Burner controls For use on industrial furnaces For burners in continuous operation Without fan control and air pressure supervision Flame supervision - with QR53... / QR55,
More informationAnnubar Flowmeter Series
Reference Manual Appendix B Approvals Annubar Flowmeter Series Hazardous Locations Installations.................. page B-1 Rosemount 3051SFA Product Certifications.......... page B-1 Rosemount 3095MFA
More informationDatasheet - AZM 161SK-12/12RK-024
Print - Create PDF - Create EXCEL file - Hide system components 21.04.2011-14:21:41h Datasheet - AZM 161SK-12/12RK-024 Solenoid interlock / AZM 161 thermoplastic enclosure Double-insulated Interlock with
More informationIECEx Certificate of Conformity
Page 1 of 10 IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate
More informationInductive slot sensor
0102 Model Number Features 2 mm slot width Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Slot width 2 mm Depth of immersion (lateral) 5... 7 mm, typ. 6 mm Output
More informationElectronic Standard Devices. Annunciator Relay. MR 11 and MRE 11 MR 21 and MRE 21
Electronic Standard Devices Annunciator Relay MR and MRE MR 2 and MRE 2 The products described in this brochure are intended for industrial use and meet the requirements laid down by the EU directive 7
More informationQAF63.2-J QAF63.6-J. Frost detectors. for use on the air side
s Frost detectors for use on the air side QAF63.2-J QAF63.6-J Active capillary tube sensor for acquiring the lowest temperature within a range of 0 15 C Operating voltage AC 24 V Signal output DC 0...10
More informationControl Panel Basics Volume 1
New Value for Control Panels Control Panel Basics Volume 1 Safety Heat Humidity Ground Fault 2 Basic Information on Control Panel Design Knowhow on Control Panel Design, from Safety Standards to Preventive
More informationSET Installation and Operating Instructions. Level switch for one sensor
Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel.: +358 29 006 260 Fax: +358 29 006 1260 7.11.2013 Internet: www.labkotec.fi 1/14 SET-1000 Level switch for one sensor Copyright 2013 Labkotec Oy
More informationTILT SENSOR SWITCH. Item No. RBS Description Ball-Contact Version 15 Page 1 of 7 Publish Date May 13, 2018
Item No RBS100600 Description Ball-Contact Version 15 Page 1 of 7 Publish Date May 13, 2018 FUNCTION 25 Tilt Detecting for 4 Directions in horizontal position APPLICATIONS 1 Wake up systems for power saving,
More information6600 SERIES 8-Pin DIP, Subminiature Bimetal Disc Thermostat
6600 SERIES 8-Pin DIP, Subminiature Bimetal Disc Thermostat Introduction The Airpax 6600 series is a RoHS compliant, positive snap action, single pole / single throw, sub-miniature bimetallic thermostat
More informationPD100MF0MPx. Surface Mount Type, Opaque Resin Photodiode. PD100MF0MPx. Agency Approvals/Compliance. Features. Model Line-up.
PD100MF0MPx Surface Mount Type, Opaque Resin Photodiode Features 1. Compact and thin SMD package 2. Top view and side view mountable 3. Plastic mold with visible light cut-off black resin lens 4. Peak
More informationNO (SPST-NO) 10 A Internal installations Particularly suited for wall mounting
Features PIR movement detector for internal or external installations - wall mounting Small size Adjustable ambient light intervention threshold Adjustable Light On Time Universal mounting position - permits
More informationOilSET Installation and Operating Instructions. Oil Separator Alarm Device
Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel: +358 29 006 260 Fax: +358 29 006 1260 18.11.2010 Internet: www.labkotec.fi 1/10 OilSET-1000 Oil Separator Alarm Device Copyright 2010 Labkotec
More information3NT SERIES FIXED TEMPERATURE THERMOSTATS Introduction
3NT SERIES FIXED TEMPERATURE THERMOSTATS Introduction Automatic reset thermostat designed to meet your specific application requirements. Its patented and tamper proof snap action bi-metal disc provides
More informationDatasheet - AZM 161SK-12/12RK-024
30.10.2017-13:15:19h Datasheet - AZM 161SK-12/12RK-024 Solenoid interlock / AZM 161 Preferred typ Thermoplastic enclosure Double-insulated Interlock with protection against incorrect locking. 130 mm x
More informationISOMETER isomed427p. Application Medical IT system in accordance with IEC , IEC , IEC and DIN VDE
Insulation monitoring device with integrated load and temperature monitoring and locating current injector for insulation fault location systems for medical IT systems _D00043_02_D_XXEN/09.2016 Insulation
More informationCE GUIDELINE IEC. CENELEC (Comité Européen de Normalisation Electrotechnique European Electrotechnical Standardisation Comitee)
INDUSTRIAL GROUP PRODUCT BROCHURE 2014 CE GUIDELINE CE Mark is the abbreviation of Conformity European and in literature mainly means conformity to European Norms. Any product or any product group carrying
More informationIT AFEM. Table of Contents. Error! Table not allowed in footnote, endnote, header, footer, comment, or text box.
IT AFEM Table of Contents Error! Table not allowed in footnote, endnote, header, footer, comment, or text box. IT [Type text] B WWW.ITENCLOSURESYSTEMS.COM [Type text] TEKPAN AUTOMATIC FIRE EXTINGUISHING
More informationIR25 Dual Gas Series Datasheet
SGX Europe Sp. z o.o. IR25 Dual Gas Series Datasheet Infrared Dual Gas Sensor for Mining (Portable and Fixed Systems) The SGX infrared sensors use the proven Non-Dispersive Infrared (NDIR) principle to
More informationTSXAEY1614C analog input module - 16 inputs - thermocouple - 16 bits
Characteristics analog input module - 16 inputs - thermocouple - 16 bits Product availability : Stock - Normally stocked in distribution facility Price* : 5684.45 USD Main Range of product Product or component
More informationSET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions
SET-000 Oil/Sludge Alarm Device for Oil Separators Copyright 007 Labkotec Oy We reserve the right for changes without notice TABLE OF CONTENTS GENERAL... INSTALLATION... 4. SET-000 Oil/Sludge Control Unit...
More informationMODEL: 47LCT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White
Digital Panel Meters 47 Series CT DIGITA PANE METER (4½ digit, ED display type, true RMS sensing) Functions & Features 4 ½ digit CT input digital panel meter 1/8 DIN size Moving average function to suppress
More information7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management
Reyrolle Protection Devices 7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management 7XG3120 - Arc Fault Monitor Relay The over-current caused by an arc is, due to its resistance, lower than the over-current
More informationOperating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA
Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 4.1 Electrical limit switch... 4
More informationThermostat RT. Data sheet
Data sheet Thermostat RT RT thermostats incorporate a temperature controlled, single-pole change over switch where the contact position depends on the temperature of the sensor and the set scale value.
More informationGillelejevej 30b DK-3230 Graested Tel.: Fax: Member of the NIBE Group
Gillelejevej 30b DK-3230 Graested Tel.: +45 48 39 88 88 - Fax: +45 48 39 88 88 info@san-as.com - www.san-as.com Member of the NIBE Group A bit of history... SAN Electro Heat a/s - previously Svend A. Nielsen
More informationFeatures. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign
Features DATASHEET Connects to multiple sensing instruments One/Two Channel Device Bright solid state LED Alarm Display Audible Alert (internal and external) High reliability, fully dual redundant alarm
More informationNGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3
NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM Local configuration and monitoring with Raychem Touch 1500 touch screen display PRODUCT OVERVIEW The Raychem NGC-40 is a multipoint electronic
More informationWelcome to Hager Presentation
Welcome to Hager Presentation Topics Intro to Hager Group Circuit Protection Enclosures Q&A IIEE Manila 4 th August 17 13.03.2009 2 Company presentation Who we are Hager Group is a leading provider of
More informationOverload relays. General descriptions. Configuration of the front
Overload relays General descriptions Type MT, bimetal-style, overload relays are designed to protect AC circuits and motors against overloads, phase failure, long starting times and prolonged stalling
More informationOperating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content
8 Appendix 8.1 Wiring examples...4 8.2 Start configuration...4 8.3 Sensor configuration...4 8.4 Actuator configuration...5 Operating instructions.............pages 1 to 6 Original 9 EU Declaration of conformity
More informationRE-PR3-E-27 3-Phase Panel Mount 27kW
Page 1 of 6 RE-PR3-E-27 3-Phase Panel Mount 27kW Features: Benefits: 0-10Vdc, 0-5Vdc, 4-20mA or manual via potentiometer control input Over temperature protection with auto reset Enclosed panel mounting
More informationUsed as indicators of indicating the Degree, Functions, Positions etc, in electronic instruments
Features Low power consumption High efficiency and low cost Good control and free combinations on the colors of LED lamps Good lock and easy to assembly. Stackable and easy to assembly Stackable vertically
More informationAPA501. Series AMPSS. Heatsinks for Power Modules Technical Reference Manual. Series Highlights
AMPSS Astec Modular Power Supply System APA5 Series Heatsinks for Power Modules Technical Reference Manual Series Highlights Horizontal, Vertical and Low Profile fin options Full range of mounting accessories
More informationHMN-D2 Insert Series
HMN-D2 Insert Series Table of contents 1. SCOPE... 2 1.1. Content... 2 1.2. Qualification... 2 2. APPLICABLE DOCUMENTS... 2 2.1. TE Connectivity Documents... 2 2.2. Other Documents... 2 3. REQUIREMENTS...
More informationLINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage
LINETRAXX VME420 Multi-functional monitoring relay for undervoltage, overvoltage and frequency monitoring in AC/DC systems with separate supply voltage VME420_D00026_01_D_XXEN/06.2016 LINETRAXX VME420
More informationOperating Manual MS220DA
ZIEHL industrie elektronik GmbH + Co KG Daimlerstraße 13, D 74523 Schwäbisch Hall + 49 791 504-0, info@ziehl.de, www.ziehl.de Temperature Relays and MINIKA Mains Monitoring Digital Panel Meters MINIPAN
More informationA214B/SUG/S400-X6 LAMP. Features. Description. Applications. Revision 1. Expired Period: Forever. LifecyclePhase: Low power consumption
Features Low power consumption High efficiency and low cost Good control and free combinations on the colors of LED lamps Good lock and easy to assembly. Stackable and easy to assembly Stackable vertically
More informationHTC-915-CONT. Heat-Trace Control system
Heat-Trace Control system Product overview The Raychem HTC-915 system is a compact, full-featured microprocessor-based single-point heat-trace controller. The HTC-915-CONT provides control and monitoring
More informationQAF64.2-J QAF64.6-J. Frost detector. for use on the air side
s Frost detector for use on the air side QAF64.2-J QAF64.6-J With active capillary tube sensing element for acquiring the lowest temperature within a range of 0 15 C With startup function Operating voltage
More informationInstruction manual. Digital Radar Motion Detector with Infrared Remote Control MWD BF. FEIG ELECTRONIC GmbH Lange Straße Weilburg/Lahn
Instruction manual Digital Radar Motion Detector with Infrared Remote Control MWD BF FEIG ELECTRIC GmbH Lange Straße 4 35781 Weilburg/Lahn 22.08.02 MWD BF Instruction manual General Copyright 2002 by FEIG
More informationSET-2000 Oil/Sludge 12 VDC
Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel: + 358 29 006 260 Fax: + 358 29 006 1260 12.2.2015 Internet: www.labkotec.fi 1/14 SET-2000 Oil/Sludge 12 VDC Alarm Device for Oil Separators with
More informationMODEL: 47LPQ. Digital Panel Meters 47 Series. [3] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points
Digital Panel Meters 47 Series PULSE INPUT TOTALIZER (6-digit, LED display type) Functions & Features 6-digit digital panel meter 1/8 DIN size Process integration/totalization with scaling factor adjustment
More informationUser manual and installation instruction Control for Fire Ventilation RV / RV 24-32
User manual and installation instruction Control for Fire Ventilation RV 24-24 / RV 24-32 Fire ventilation Comfort ventilation 24VDC max. 24/32A 2 Actuator outputs 1 Fire ventilation group, 2 comfort groups
More informationVAMP 120 & 121. Arc flash detection units. Product picture
Arc flash detection units VAMP 120 and 121(D) are extremely fast arc flash detection units for LV and MV switchgear and controlgear. The units are especially designed to increase the safety and to minimize
More informationArc Fault Protection System D1000
Arc Fault Protection System D1000 Improve personnel safety Reduce damage Avoid costly repairs Minimize production downtime www.selco.com Segments & applications In all areas where electrical energy is
More informationD1000 Arc-fault Protection System
D1000 Arc-fault Protection System Improve personnel safety Reduce damage and minimize costly repairs Minimize production downtime www.selco.com D1000 Arc-Fault Protection system Efficient protection of
More informationTechnical Data. General specifications. Rated operating distance s n 5 mm
0102 Model Number Features 5 mm non-flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Rated operating distance s n 5 mm
More informationSeries. Unique PCB mounting system.
Series 71 Unique PCB mounting system. www.eao.com Series 71 Unique PCB mounting system. Unique printed circuit board (PCB) technology enables the Series 71 to provide versatile and modular opportunities
More informationIntroducing Hermaphroditic Blade and Receptacle Connector
Introducing Hermaphroditic Blade and Receptacle Connector Wire-to-Board, Board-to-Board and Dust Cover Hermaphroditic Blade and Receptacle Connector : Wire-to-Board KEY FEATURES Available in 2, 4, and
More informationpre-wired E3FA-TP11-F2 2M E3FB-TP11-F2 2M
PHOTOELECTRIC SENSORS EFA/B_-F Special family with inverted output logic Fully compatible with previous EF family Simple installation due to compact format Wide variety of models Ordering Information EFA/B
More informationSET-2000 Hi Level/Oil
Labkotec Oy Labkotie 1 FI-36240 KANGASALA FINLAND Tel: + 358 29 006 260 Fax: + 358 29 006 1260 13.03.2008 Internet: www.labkotec.fi Alarm Device for Oil Separators Copyright 2008 Labkotec Oy We reserve
More informationFrost Protection Thermostat
1 203 Frost Protection Thermostat Electromechanical thermal reset limit thermostat RAK-TW.5..H RAK-TW.5..H.. Use Monitoring of frost protection temperature, with single-pole changeover microswitch Switching
More informationOnline data sheet WS/WE45-P260S01 W45 PRODUCT PORTFOLIO
Online data sheet WS/WE45-P260S01 W45 B C D E F Illustration may differ Detailed technical data Features Ordering information Type Part no. WS/WE45-P260S01 1016031 Other models and accessories www.sick.com/w45
More informationI ntroduction. Series F61. Liquid Flow Switches. Feature and Benefits
PSC9720 European Refrigeration Controls Catalogue Catalog Section 3 Product Bulletin F61 Series F61 Liquid Flow Switches I ntroduction The F61 liquid flow switches can be used in liquid lines carrying
More information1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection
Technical Bulletin Arc Fault Monitor 4 Zones, 8 Sensors Features Four independent arc fault tripping zones 1 or 2 arc fault sensors per zone allowing up to 8 arc fault sensors per module Trip indication
More informationCertificate of Compliance
FF0002 Certificate of Compliance Certificate: 2385571 Project 2447891 Issued to: Mine Safety Appliances 1000 Cranberry Woods Drive Cranberry Township, PA 16066 USA Issued by: Jocelyn Jens Product Group
More informationFree Height 0.8 mm Pitch Board-to-Board Connector (SMT)
Product 108-5390 Specification 31 OCT 17 Rev.F1 Free Height 0.8 mm Pitch Board-to-Board Connector (SMT) 1. SCOPE 1.1. Contents This specification covers the requirements for product performance, test methods
More informationScully ST-15 WX. Technical Manual. Multi-Point Liquid-Level Detection System
Scully ST-15 WX Technical Manual Multi-Point Liquid-Level Detection System MaxSafety SYSTEMS Scully Signal Company / Tel. 617 692 8600 / Fax. 617 692 8620 / 800 2 SCULLY (272 8559) 70 Industrial Way, Wilmington,
More informationExcellence in Level Measurement
Technical Data Sheet No. Novaflo 2000 'Fail-Safe' Level Alarm System Excellence in Level Measurement Afriso Eurogauge Ltd Imberhorne Lane, East Grinstead West Sussex. RH19 1RF Tel: 01342 323641 Fax: 01342
More informationNGC-20-C-E and NGC-20-CL-E
Field-mounted Electronic heat-tracing control unit Product overview The DigiTrace NGC-20 is an electronic heat-tracing control unit featuring the benefits of local control and the capability for central
More informationUser's Manual: Series 260A Model 260A Process Current Loop-Powered Alarm
User's Manual: Series 260A Model 260A Process Current Loop-Powered Alarm Table of Contents Page Introduction 1 Description 1 Specifications 2 Installation 3 Calibration 4 General Maintenance 5 List of
More informationR-GAGE QT50R-AFS Sensor
Datasheet Radar-Based Sensors for Detection of Moving and Stationary Targets FMCW (true-presence) radar detects moving and stationary objects Higher sensitivity and shorter range Adjustable sensing field
More informationOutput module (230 V)
Cerberus FIT Output module (30 V) FCA109-Z1 Output module for use in monitored output lines Output with potential-free relay contacts for controlling fire ventilators, air conditioning systems, elevators,
More informationSENSOR SWITCH BRAVOTRONICS CORPORATION 松瓚科技股份有限公司. Item No. VBS080100T Description VIBRATION SWITCH Version 8 Page 1 of 10 Date Nov.
Page 1 of 10 Date Nov. 20, 2013 FUNCTIONS Vibration detecting for vertical PCB APPLICATION 1. Wake up systems for power saving, such like remote controllers 2. GPS starting system 3. Alarm system 4. Anti-theft
More informationRoom thermostat with 24-hour time switch and large LCD
Room thermostat with 24-hour time switch and large LCD RDJ100 Programmable, for heating systems Operating modes: Automatic, Comfort, Energy saving, and Frost protection Large LCD display Battery powered:
More informationMODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power
Digital Panel Meters 47 Series THERMOCOUPLE INPUT DIGITAL PANEL METER (4-digit, LED display type) Functions & Features 4-digit thermocouple input digital panel meter 1/8 DIN size Moving average function
More informationUltrasonic Reflective Sensor
Ultrasonic Reflective with an Adjustable Sensing Distance of 0.3 to 3 m Under Stable Operation without Background Interference Ensures a stable operating range with minimal side-lobe areas. Built-in unstable
More informationLAE10 LFE10. Use. Series 02
ISO 00 Flame Safeguards 7 7 LAE L Series 02 Supplementary data sheets 772 and 773 Flame safeguards for burners with intermittent operation. For safety reasons - self-test of flame supervision circuit,
More informationDatasheet - AZM ZRK 24 VAC/DC
Print - Create PDF - Create EXCEL file - Hide system components 21.04.2011-10:13:56h Datasheet - AZM 170-02ZRK 24 VAC/DC Solenoid interlock / AZM 170 thermoplastic enclosure Double-insulated Compact design
More informationOPTISENS TUR 2000 Technical Datasheet
OPTISENS TUR 2000 Technical Datasheet Sensor for turbidity measurement in water and wastewater Rugged design for harsh applications Integrated transmitter with direct 4...20 ma output Near infrared light
More informationFIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module
FIRE ALARM CONTROL EQUIPMENT Addendum October 2006 Instructions for new style EN54-4 Power supply unit module MXLK-05 Issue 2.0 June 2007 INSTALLATION Safety Suppliers of articles for use at work are required
More informationResidual Current Devices
Residual devices F200 Series UL 1053 Residual devices F200 Series Residual Current Devices Description The F200 Series residual devices offer a wide range of product for all of your fault protection needs.
More informationNGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW
NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM Local configuration and monitoring with Raychem Touch 1500 touch screen display PRODUCT OVERVIEW The nvent RAYCHEM NGC-40 is a multipoint
More informationSeries F61. Liquid Flow Switches. Feature and Benefits. T-body and Pipe-insert types available
PSC9720 European Refrigeration Controls Catalogue Catalog Section 3 Product Bulletin F61 Series F61 Liquid Flow Switches I ntroduction The F61 liquid flow switches can be used in liquid lines carrying
More informationInstallation Guide. BasicPlus 2 WT-DR & WT-PR Room Thermostats
Room Thermostats GB Installation Guide 1. Installation Steps User Guide can be downloaded from: heating.danfoss.com. 1. Installation must be done by an authorised electrician. 2. The room thermostat should
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61810-1 Second edition 2003-08 Electromechanical elementary relays Part 1: General and safety requirements Relais électromécaniques élémentaires Partie 1: Exigences générales
More informationUniversal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01
Gamma instabus Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG1 528-1DB01 Technical Product Information Universal Dimmer for switching or dimming of dimmable lamps Supports dimmable lamps including
More information2. Contact form 6: 1c (SPDT) Load voltage (peak value) quantity Fully Sealed 1c (SPDT) 5 VDC 5 VDC 60 V 400 ma 130 ma G3VM-66M 50 pcs/tube
MOS FET Relay in module package with SPDT (1C) This model of operated by voltage (Rated input voltage is 5 VDC.) Contribute to reduce the mounting space on the print circuit board by small package Contact
More informationORION-FWS. Computer for feed weighing
AA 1 4 7 2 5 8 Computer for feed weighing Hotraco Agri BV Stationsstraat 142, NL - 5 AC Hegelsom, PO Box 8, 5 AB Horst, The Netherlands Tel: +1 ()77 2752 Fax: +1 ()77 27521 Internet: wwwhotracocom Computer
More information