Fire Extinguishing System

Size: px
Start display at page:

Download "Fire Extinguishing System"

Transcription

1 Fire Extinguishing System Fire Protection CAUTION CAUTION 1 EXTINGUISHER PUSH L ENGINE FIRE R FW VALVE CLOSED TO TEST R ENGINE FIRE R FW VALVE CLOSED EXTINGUISHER PUSH 2 TEST SWITCH 1 ANNUNCIATOR PANEL 3 FIRE EXTINGUISHER SUPPLY CYLINDER LEFT MONITOR MODULE RIGHT MONITOR MODULE 2 ENG FIRE TEST DET LEFT OFF EXT RIGHT B3CRH-FR001i King Air 350 Developed for Training Purposes 4C-1 February 2006

2 CAE SimuFlite Fire Detection System CAUTION CAUTION 1 EXTINGUISHER PUSH L ENGINE FIRE R FW VALVE CLOSED TO TEST R ENGINE FIRE R FW VALVE CLOSED EXTINGUISHER PUSH 3 FIRE SENSOR ELEMENT 1 ANNUNCIATOR PANEL 2 TEST SWITCH PRINTED CIRCUIT CARDS 3 FIRE SENSOR ELEMENT 2 ENG FIRE TEST DET OFF EXT LEFT RIGHT 3 28 V DC TEST SWITCH LEFT OR RIGHT ENGINE SENSOR RESPONDER SIMPLIFIED CIRCUIT B C D RESPONDER ALARM SWITCH (N.O.) SENSOR ELEMENT INTEGRITY SWITCH N.C. HELD CLOSED BY NORMAL SENSOR URE B3CRH-FR002i 4C-2 Developed for Training Purposes King Air 350 February 2006

3 Fire Protection Bleed Air Warning System ENVIRONMENTAL MIXING PLENUM L BLEED FAIL R BLEED FAIL ENGINE BLEED AIR AMBIENT AIR FLOW CONTROL UNIT AFT FIREWALL PLUGS AIR INLET BLEED AIR SWITCHES ENVIRONMENT BLEED AIR SHUTOFF VALVE (N.C.) PNEUMATIC BLEED AIR SHUTOFF VALVE (N.O.) AIR-TO-AIR HEAT EXCHANGER CABIN HEAT CONTROL VALVE LEFT BLEED AIR LINE (POLY FLOW TUBING) RIGHT BLEED AIR LINE (POLY FLOW TUBING) BLEED AIR LINE URIZATION BLEED AIR PNEUMATIC BLEED AIR AMBIENT COOLED BLEED AIR B3CRH-FR003i King Air 350 Developed for Training Purposes 4C-3

4 CAE SimuFlite 4C-4 Developed for Training Purposes King Air 350

5 Fire Protection Fire Protection Systems Fire protection systems include: engine fire detection engine fire extinguishing testing (fire detection and extinguishing) bleed air warning. Engine Fire Detection Engine fire detection consists of temperature sensing cables, two red warning annunciators (ENG FIRE), and two test switches. When an engine fire occurs, the ENG FIRE light and the annunciator on the glareshield panel illuminate. Each engine's temperature sensing element consists of a sealed stainless steel tube. Within this tube is an inert gas and an inner core with an active gas. The sensing element connects to a responder that contains an alarm switch for detection and an integrity switch for testing. Exposing a sensing element to temperatures of 360 F (182 C) along its entire length or 800 F (426 C) along a one-foot section expands the element's core gases. This closes the responder alarm switch to illuminate the respective ENG FIRE light and trigger the flashing lights. Once the sensing element cools below its trigger temperature, the ENG FIRE light extinguishes. The lights, however, do not extinguish until they are reset. King Air 350 Developed for Training Purposes 4C-5

6 CAE SimuFlite Engine Fire Extinguishing The engine fire extinguishing system consists of a fire extinguisher bottle in each main wheel well. Spray nozzles connected to each bottle direct fire extinguishing agent to the engine accessory section and power sections. Each bottle contains approximately 2.5 Ib of Bromotrifluoromethane (CBrF3) pressurized with dry nitrogen to PSI at 72 F (pressurization is directly proportional to OAT). The fire detection system illuminates the ENG FIRE annunciator. Pressing the switch will activate the fire extinguishing system and close the fuel firewall shutoff valve. Once the system has been armed, the EXTINGUISHER PUSH annunciator will come on. Pressing that light supplies DC power to the extinguisher bottle's explosive squib. The squib's detonation dislodges a sealing disc so that bottle contents flow to the spray nozzles. Once the squib integrity has been compromised, the respective DISCHARGE annunciator illuminates. Testing (Fire Detection and Extinguishing) The testing system consists of two independent switches labelled ENG FIRE TEST/LEFT/RIGHT with DET, OFF and EXT positions. When either switch is selected to DET, the corresponding ENG FIRE and lights will illuminate. Selecting either switch to EXT will illuminate the corresponding EXTINGUISHER PUSH and DISCHARGE annunciator. 4C-6 Developed for Training Purposes King Air 350

7 Engine Bleed Air Warning Fire Protection EVA tubing that parallels the bleed air lines from the engine firewalls into the cabin provides a warning system for a bleed air leak. These parallel tubing lines are pressurized with instrument bleed air. If a bleed air line ruptures, excessive heat melts the adjacent EVA tubing to release pressure. When pressure is reduced, a switch in the line under the copilot floor closes to illuminate the respective L/R BLEED FAIL annunciator. King Air 350 Developed for Training Purposes 4C-7

8 CAE SimuFlite Fire Protection System Power Source Distribution Control Monitor Protection Dual-fed bus (fire extinguisher) Triple-fed bus (fire detection) Extinguisher bottle to corresponding engine (no crossfiring) Portable hand fire extinguishers Left and right F/W VALVE PUSH CLOSED Switches Left and right switches Left and right TEST switches Annunciators ENG FIRE EXTINGUISHER-PUSH flashers Circuit card assembly fire extinguisher Circuit breakers 4C-8 Developed for Training Purposes King Air 350

Engine Fire Protection System

Engine Fire Protection System Engine Fire Protection System 1 1 LEFT FEED BUS LEFT CB PANEL CROSSOVER RIGHT FEED LEFT CB PANEL Fire Protection ARM UNLOCK DEPLOY S T EMER O W S NORM W BOTTLE 1 ARMED PUSH LH ENG FIRE PUSH RH ENG FIRE

More information

Bombardier Challenger Fire Protection

Bombardier Challenger Fire Protection GENERAL The fire protection system is divided into two separate subsystems: Fire and overheat detection system; and Fire extinguishing system. The fire and overheat detection system includes components

More information

Pressurization System

Pressurization System Pressurization System FILTER N.O. PRESET SOLENOID MOISTURE DRAIN ALTITUDE LIMIT CONTROLLER ALTITUDE LIMIT CONTROLLER MOISTURE DRAIN OUTFLOW SAFETY STATIC AIR Environmental Systems RATE ALTITUDE VACUUM

More information

Section - III SYSTEMS DESCRIPTION

Section - III SYSTEMS DESCRIPTION Section - III SYSTEMS DESCRIPTION Table of Contents Hawker 800XP Pro Line Page GENERAL...4-3 Figure - Engine Fire Detection and Warning System Component Locations...4-3 CONTROLS and INDICATIONS...4-4 ENGINE

More information

APU FIRE EXTINGUISHING SYSTEM - DESCRIPTION AND OPERATION

APU FIRE EXTINGUISHING SYSTEM - DESCRIPTION AND OPERATION 1.General APU FIRE EXTINGUISHING SYSTEM - DESCRIPTION AND OPERATION A.The APU fire extinguishing system has controls in two locations that release one application of fire extinguishing agent to a fire

More information

SECTION 2-07 FIRE PROTECTION

SECTION 2-07 FIRE PROTECTION SECTION 2-07 TABLE OF CONTENTS Block General... 2-07-05..01 Engine and APU Fire Protection System... 2-07-10..01 Fire/Overheat Detection... 2-07-10..01 Fire Extinguishing... 2-07-10..04 Controls and Indicators...

More information

SECTION 6-15 FIRE PROTECTION

SECTION 6-15 FIRE PROTECTION SECTION 6-15 SYSTEMS DESCRIPTION Index Page General Description... 6-15-2 Engine Fire Protection... 6-15-2 Engine Fire Detection... 6-15-2 Engine Extinguishing... 6-15-3 Engine/Wheelwell and Pipe Zone

More information

DASSAULT AVIATION Proprietary Data

DASSAULT AVIATION Proprietary Data F2000EX EASY 02-26-00 CODDE 1 PAGE 1 / 2 TABLE OF CONTENTS 02-26 02-26-00 TABLE OF CONTENTS 02-26-05 GENERAL Introduction Sources 02-26-10 DESCRIPTION Introduction Fire detection Fire extinguishing Portable

More information

DC3Training.com N28AA DC-3 Pilot s Handbook

DC3Training.com N28AA DC-3 Pilot s Handbook SECTION 7 FIRE PROTECTION Index General page 2 Operation page 4 Limitations page 4 Troubleshooting page 5 4/19/2012 crew@dc3training.com 1 GENERAL The fire protection system consists of an Edison fire

More information

TABLE OF CONTENTS FIRE PROTECTION. Page. 9-i

TABLE OF CONTENTS FIRE PROTECTION. Page. 9-i Chapter 9: Fire Protection TABLE OF CONTENTS Page Introduction...9-1 Flight Compartment Fire Warning...9-2 Fire Detecting System...9-2 Main Wheel Well Overheat Warning...9-2 Fire Agent Discharge Indication...9-2

More information

FIRE PROTECTION TABLE OF CONTENTS CHAPTER 9

FIRE PROTECTION TABLE OF CONTENTS CHAPTER 9 TABLE OF CONTENTS CHAPTER 9 Page TABLE OF CONTENTS DESCRIPTION General Flight Compartment Fire Warning Fire Detecting System Wheel Well Overheat Warning Fire Agent Discharge Indication Smoke Detection

More information

WARNING AND TEST MASTER WARNING AND MASTER CAUTION SYSTEMS

WARNING AND TEST MASTER WARNING AND MASTER CAUTION SYSTEMS WARNING AND TEST MASTER WARNING AND MASTER CAUTION SYSTEMS The Warning and Caution systems are discussed here in conjunction with the Warning and Test Systems, primarily to cover the procedures for testing

More information

Fokker 50 - Fire Protection

Fokker 50 - Fire Protection ENGINE General The engines are each equipped with a fire detection and a fire extinguishing system. The systems are controlled from the ENGINE FIRE panel, which is located at the overhead panel. Fire and

More information

WARNING AND TEST MASTER WARNING AND MASTER CAUTION SYSTEMS

WARNING AND TEST MASTER WARNING AND MASTER CAUTION SYSTEMS MODEL 680 WARNING AND TEST MASTER WARNING AND MASTER CAUTION SYSTEMS The Warning and Caution systems are discussed here in conjunction with the Warning and Test Systems, primarily to cover the procedures

More information

Section - III SYSTEMS DESCRIPTION

Section - III SYSTEMS DESCRIPTION Section - III SYSTEMS DESCRIPTION Pro Line 21 Table of Contents Page GENERAL...1-3 ANNUNCIATOR TYPES...1-3 ARRANGEMENT...1-3 REPEATER ANNUNCIATORS...1-3 Figure 1 - Master Warning Annunciations and Controls...1-4

More information

FIRE EXTINGUISHING SYSTEM

FIRE EXTINGUISHING SYSTEM SEEGER. FIRE EXTINGUISHING SYSTEM 443cl TICHlllCAL TRAINING SQUADRON 44311 MILITARY AIRLIFT W G, ING (MAC) ALTUS AIR FORCE BASE, OKLAHOMA A FIRE E){TINGUISHING SYST~ OBJECTIVES~ When you complete this

More information

Service Bulletin No. 2930

Service Bulletin No. 2930 Service Bulletin No. 2930 MODEL TYPE SECTION/GROUP DATE E / J Series Coaches Service Information 8--Engine Mar. 30, 2006 SUBJECT AMEREX FIRE SUPPRESSION SYSTEM CONDITIONS Service Information Only Description:

More information

CIRRUS AIRPLANE MAINTENANCE MANUAL

CIRRUS AIRPLANE MAINTENANCE MANUAL MODEL SR INDICATING/RECORDING SYSTEMS 1. DESCRIPTION This section describes the Indicating/Recording Systems which consists of an Annunciator Panel and related sensors and switches. The annunciator assembly

More information

71717 SERIES FLAMMABLE MATERIAL LOCATIONS

71717 SERIES FLAMMABLE MATERIAL LOCATIONS 71 FLAMMABLE MATERIAL LOCATIONS (tab) CAUTION: Rescue crews wearing full PPE to include SCBA s must use caution when moving across sections of aircraft that have been exposed to fatigue or fire as the

More information

Instrument and Control Panels

Instrument and Control Panels GENERAL Instrument and Control Panels 31-10: INSTRUMENT AND CONTROL PANELS 1. General A. Instrument Panel A Garmin Primary Flight Display (PFD) is mounted in the instrument panel. The Engine Start Controls

More information

T0158_ATRcouvDEF_SYSTEM42notPEC.indd COUV1 19/05/10 16:29

T0158_ATRcouvDEF_SYSTEM42notPEC.indd COUV1 19/05/10 16:29 42-300 Introduction This Systems guide is an essential tool for all ATR flight crew and engineer to learn or review ATR systems operation. To make learning process easier, systems are introduced in a user-friendly

More information

Memory Items 2

Memory Items 2 Flash Cards 1 Memory Items 2 Memory Items ENGINE FAILURE/EMERGENCY ENGINE SHUTDOWN 3 Memory Items ENGINE FAILURE/EMERGENCY ENGINE SHUTDOWN 1. Condition lever FUEL CUTOFF 2. Propeller lever FEATHER 3. Firewall

More information

6-1 Installing Batteries 6-2 Automatic Circuit/Reset Feature 6-3 Feature Sensitivity Adjustment

6-1 Installing Batteries 6-2 Automatic Circuit/Reset Feature 6-3 Feature Sensitivity Adjustment CONTENT Page 1. GENERAL INFORMATION ------------------ 2 2. FEATURES ---------------------------------------- 2 3. SPECIFICATION --------------------------------- 3 4. OPERATION GUIDE ---------------------------

More information

CIRRUS AIRPLANE MAINTENANCE MANUAL

CIRRUS AIRPLANE MAINTENANCE MANUAL All HEATING 1. DESCRIPTION The cabin air heating system is covered in this section. Serials 1005 thru 138: Heated air is available at floor level for all occupants. Positive pressure inside the engine

More information

Fokker 50 - Integrated Alerting Unit

Fokker 50 - Integrated Alerting Unit GENERAL Failure conditions are processed by an Integrated Alerting Unit (IAU) for visual and aural presentation to the pilots. Pre-stall warning and ground proximity warning are not integrated. The IAU

More information

FAA APPROVED AIRPLANE FLIGHT MANUAL SUPPLEMENT

FAA APPROVED AIRPLANE FLIGHT MANUAL SUPPLEMENT SUPPLEMENTAL TYPE CERTIFICATE NUMBER SA11103SC INSTALLATION OF SAFETY SYSTEMS FOR BEECHCRAFT B200GT AND B200CGT AIRPLANES IN THE KING AIR 250 CONFIGURATION (PRO LINE 21 AND PRO LINE FUSION AVIONICS) FAA

More information

A D U ANNUNCIATOR DIM / TEST UNIT INSTALLATION MANUAL DESCRIPTION AND THEORY OF OPERATION

A D U ANNUNCIATOR DIM / TEST UNIT INSTALLATION MANUAL DESCRIPTION AND THEORY OF OPERATION AVIONICS ENGINEERING SERVICES A D U ANNUNCIATOR DIM / TEST UNIT INSTALLATION MANUAL DESCRIPTION AND THEORY OF OPERATION Document No. 92-0003-06 REV C May 31, 2000 INSTALLATION MANUAL DESCRIPTION AND THEORY

More information

CHAPTER 11 HEATING AND VENTILATION

CHAPTER 11 HEATING AND VENTILATION CHAPTER 11 HEATING AND VENTILATION Section Title Page 11.000 Heating and Ventilation...................................... 11.1 11.001 Introduction........................................... 11.1 11.002

More information

contents iii Drilling Tools 27 Adjustable Choke 27 Automatic Drillers 29 MWD and LWD Tools 30 How They Work 30 Uses 30

contents iii Drilling Tools 27 Adjustable Choke 27 Automatic Drillers 29 MWD and LWD Tools 30 How They Work 30 Uses 30 Figures v Foreword ix Acknowledgments xi Units of Measurement xii Introduction 1 Pipe Handling Equipment 3 Kelly Spinners 3 Maintenance 6 Spring Slips and Power Slips 7 Maintenance 9 Automatic Pipe Handlers

More information

631RF Amp Power Supply

631RF Amp Power Supply 631RF - 1.5 Amp Power Supply Modular Access Control Power Supply Field Selectable 12VDC or 24VDC Output - Standard Dual 12VDC and 24VDC Output - Optional Quality, Performance and Versatility The SDC 631RF

More information

Agent Tanks PCL PCL PCL PCL - 600

Agent Tanks PCL PCL PCL PCL - 600 Components Pg 2-1 Agent Tanks PCL - 160 PCL - 300 PCL - 460 PCL - 600 Model No. Diameter Height to top of valve Height with control head Height to valve outlet Weight PCL - 160 8.00 in. 17.65 in. 23.50

More information

Basic Vehicle Fire Protection Manual

Basic Vehicle Fire Protection Manual Basic Vehicle Fire Protection Manual Basic Vehicle Fire Protection Manual TABLE OF CONTENTS Introduction... 3 System Operation...... 5 Component Overview.... 7 Operator Controls Control Panel.........

More information

GAS FLOODING SYSTEM FOR CIFF AT BASEMENT

GAS FLOODING SYSTEM FOR CIFF AT BASEMENT CONSTRUCTION OF BUILDINGS FOR LABORATORIES AND ASSOCIATED FACILITIES INSTEM BANGALORE SCHEDULE OF QUANTITIES FOR (EQUIPMENT ROOM 3 & 4) Sl.No. Description Unit Quantity Rate (in INR) in figure HFC-227ea

More information

182T and T182T Air Conditioning System ICA Revision: Date: 17 September, 2008

182T and T182T Air Conditioning System ICA Revision: Date: 17 September, 2008 Document Number: NC-08-037 Title: 182T and T182T Air Conditioning System ICA Revision: C Date: 17 September, 2008 Name Signature Date Author Erik Pederson Signed Copy On File 9/17/08 Approved Erik Pederson

More information

Power Units & Test Systems

Power Units & Test Systems Advanced Air Driven Power Units Power Units & Test Systems Sprague Products Division of Curtiss-Wright Flow Control Corporation TECHNOLOGY THAT CHANGES EVERYTHING Air Driven Power Units Choose an air driven

More information

CIRRUS AIRPLANE MAINTENANCE MANUAL

CIRRUS AIRPLANE MAINTENANCE MANUAL INDICATING/RECORDING SYSTEMS 1. DESCRIPTION This section describes the Indicating/Recording Systems which consists of an Annunciator Panel and related sensors and switches. A. Annunciator Panel - Serials

More information

Refrigerant Leak Detector

Refrigerant Leak Detector 380 Lo Hi Refrigerant Leak Detector 380-00 JUN. 2007 CONTENT Page 1. GENERAL INFORMATION ------------------ 2 2. FEATURES ---------------------------------------- 2 3. SPECIFICATION ---------------------------------

More information

REFERENCE ONLY FAA APPROVED AIRPLANE FLIGHT MANUAL SUPPLEMENT

REFERENCE ONLY FAA APPROVED AIRPLANE FLIGHT MANUAL SUPPLEMENT SUPPLEMENTAL TYPE CERTIFICATE NUMBER SA11103SC INSTALLATION OF SAFETY SYSTEMS FOR BEECHCRAFT B200GT AND B200CGT AIRPLANES IN THE KING AIR 250 CONFIGURATION (PRO LINE 21 AND PRO LINE FUSION AVIONICS) FAA

More information

C I R R U S HEATING DESCRIPTION A. Cabin Air Heating System - Serials thru

C I R R U S HEATING DESCRIPTION A. Cabin Air Heating System - Serials thru HEATING 1. DESCRIPTION This section covers those systems and components used to supply heated air. Includes items such as heater panels and other units, indicating systems related to heater operation,

More information

T-6B Electrical System. Created: 24 Aug 2015 Updated: 30 Aug 2015 T6BDriver.com

T-6B Electrical System. Created: 24 Aug 2015 Updated: 30 Aug 2015 T6BDriver.com T-6B Electrical System Created: 24 Aug 2015 Updated: 30 Aug 2015 T6BDriver.com Objectives Identify power sources of electrical system Understand electrical distribution within system Identify location

More information

Application Bulletin. LNG / LPG Facilities FLAME AND GAS DETECTION FOR LNG FACILITIES

Application Bulletin. LNG / LPG Facilities FLAME AND GAS DETECTION FOR LNG FACILITIES FLAME AND GAS DETECTION FOR LNG FACILITIES Liquefied natural gas (LNG) is a generic name for liquefied hydrocarbon gas composed primarily of methane. When natural gas is cooled to approximately -260 F,

More information

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER Application The unit is primarily intended for use where there is a requirement to integrate a limited fire protection function into a larger control equipment scheme, or in specialist applications where

More information

Element C3.4 Fire Fighting Equipment

Element C3.4 Fire Fighting Equipment .4 Fire Fighting Equipment Classification of Fires Class A Solids. Wood, paper, plastics Class B Liquids Petrol oil, paint Class C Gases LPG, natural gas Classification of Fires Class D Metals Zinc, sodium,

More information

MODEL 5100 VOTING LOGIC MODULE

MODEL 5100 VOTING LOGIC MODULE DESCRIPTION DESCRIPTION The SST Model 5100 Multi-Input Voting Logic Module is used to monitor the status of up to 14 different points in a hazard zone, and report when a selectable number of these points

More information

WSU-TFREC Fire Safety Training

WSU-TFREC Fire Safety Training WSU-TFREC Fire Safety Training WSU-TFREC Locate the nearest exits, alarms and fire extinguishers to your work area Floor plans are available online: Overley Building http://www.tfrec.wsu.edu/pages/safety/overley_building_floor_plan

More information

Amerex Fire Suppression Systems. Because Operators and the Environment are NOT Disposable Quality is Behind the Diamond.

Amerex Fire Suppression Systems. Because Operators and the Environment are NOT Disposable Quality is Behind the Diamond. Amerex Fire Suppression Systems Because Operators and the Environment are NOT Disposable Quality is Behind the Diamond. Quality is Behind the Diamond. Diamonds have long been a symbol for quality. At Amerex

More information

CellarSafe. Carbon Dioxide and Oxygen Safety Monitor

CellarSafe. Carbon Dioxide and Oxygen Safety Monitor CellarSafe Carbon Dioxide and Oxygen Safety Monitor Installation and operating instructions for the CellarSafe Monitor and the CellarSafe Calibration Unit M07234 May 2008 Issue 6 Warning Please take care

More information

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE GENERAL INDUSTRY SAFETY STANDARDS PART 8. PORTABLE FIRE EXTINGUISHERS

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE GENERAL INDUSTRY SAFETY STANDARDS PART 8. PORTABLE FIRE EXTINGUISHERS DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE GENERAL INDUSTRY SAFETY STANDARDS (By authority conferred on the director of the department of licensing and regulatory affairs by sections

More information

CO 2 EXTINGUISHING SYSTEMS

CO 2 EXTINGUISHING SYSTEMS CO 2 EXTINGUISHING SYSTEMS CO 2 THE FIRE EXTINGUISHING CLASSIC: CLEAN, FAST AND RELIABLE TOTAL WALTHER, the acknowledged specialist in fire protection systems, has been manufacturing CO 2 extinguishing

More information

DASSAULT AVIATION Proprietary Data

DASSAULT AVIATION Proprietary Data FALCON 7X 02-33-05 CODDE 1 PAGE 1 / 4 GENERAL ACRONYMS LIST BATT CB EPS LED LH MAU OP PPDB RH SSPC Battery Circuit Breaker Emergency Power Supply Light Emitting Diode Left Hand Modular Avionic Unit Overhead

More information

Kelly Aerospace Willoughby, OH NC , Rev. A FAA APPROVED AIRPLANE FLIGHT MANUAL SUPPLEMENT FOR LC40-550FG AIRFRAME DE-ICING SYSTEM

Kelly Aerospace Willoughby, OH NC , Rev. A FAA APPROVED AIRPLANE FLIGHT MANUAL SUPPLEMENT FOR LC40-550FG AIRFRAME DE-ICING SYSTEM Aircraft SN: Aircraft Registration Number: This supplement must be attached to the FAA approved flight manual when the Kelly Aerospace airframe de-icing system is installed in accordance with STC SA02660CH.

More information

24V PCU CORE FIRE PROTECTION INSTALLATION SUMMARY

24V PCU CORE FIRE PROTECTION INSTALLATION SUMMARY 24V PCU CORE FIRE PROTECTION INSTALLATION SUMMARY 11/12/2012 Rev. 10 Pollution Control Unit PCU CORE CONNECTIONS, 3/8" NPT CONNECTION, ONE PER MODULE LINE FROM PACKAGE MUST BE BRANCHED AND ADAPTED TO EACH

More information

SPECIFICATION FOR A TOTAL FLOOD ECARO-25 TM CLEAN AGENT FIRE SUPPRESSION SYSTEM FOR USE WITH THE CHEETAH Xi 50 CONTROL PANEL SYSTEM

SPECIFICATION FOR A TOTAL FLOOD ECARO-25 TM CLEAN AGENT FIRE SUPPRESSION SYSTEM FOR USE WITH THE CHEETAH Xi 50 CONTROL PANEL SYSTEM SECTION 1 - GENERAL CONDITIONS I. SCOPE: This specification outlines the requirements for a Total Flood ECARO-25 TM clean agent fire suppression system utilizing HFC-125 as the fire extinguishing agent

More information

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 715

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 715 INSTALLATION and INSTRUCTION MANUAL for QUALITY AIR BREATHING SYSTEMS Model ABM - 715 M A R T E C H S E R V I C E S C O M P A N Y P.O. Box 7079 OFFICE: 800-831-1525 Mazeppa, MN 55956 Fax : (507)843-4953

More information

CHAPTER - 30 HIGHLIGHTS (Summary of Changes) Revision No. TR30-6 Dec 21/18 TO: HOLDERS OF THE AIRCRAFT MAINTENANCE MANUAL ( )

CHAPTER - 30 HIGHLIGHTS (Summary of Changes) Revision No. TR30-6 Dec 21/18 TO: HOLDERS OF THE AIRCRAFT MAINTENANCE MANUAL ( ) CHAPTER - 30 HIGHLIGHTS (Summary of Changes) Revision No. TR30-6 TO: HOLDERS OF THE AIRCRAFT MAINTENANCE MANUAL (06-117751) Pages that have been added or revised are summarized below. Remove and insert

More information

24V PCU CORE FIRE PROTECTION INSTALLATION SUMMARY

24V PCU CORE FIRE PROTECTION INSTALLATION SUMMARY 24V PCU CORE FIRE PROTECTION INSTALLATION SUMMARY 06/13/2011 Rev. 6 Pollution Control Unit PCU CORE CONNECTIONS, 3/8" NPT CONNECTION, ONE PER MODULE LINE FROM PACKAGE MUST BE BRANCHED TO EACH MODULE..

More information

3. Low location lighting system. 4. Illuminated emergency units. 5. Cabin escape route plans

3. Low location lighting system. 4. Illuminated emergency units. 5. Cabin escape route plans 1. Signs for fire protective installation 2. Signs for escape routes 3. Low location lighting system 4. Illuminated emergency units 5. Cabin escape route plans 117 1.SIGNS FOR FIRE PROTECTIVE INSTALLATION

More information

Hazardous goods management Latest trends in petroleum industry. C. Sasi Assistant Vice President Total LPG India Limited

Hazardous goods management Latest trends in petroleum industry. C. Sasi Assistant Vice President Total LPG India Limited Hazardous goods management Latest trends in petroleum industry C. Sasi Assistant Vice President Total LPG India Limited Buncefield UK (HOSL) - December 11, 2005 Training Behaviour SMS LOPA Risk Analysis

More information

Alarm Panel Operating Instructions

Alarm Panel Operating Instructions Alarm Panel Operating Instructions 1.0 Introduction The Gascon Systems G8850 alarm panel is designed to be used with gas reticulation systems. It is available in single, twin and triple input channel models.

More information

Dornier 328Jet - Lights

Dornier 328Jet - Lights LIGHT and ENGINE START Control Panel (Sheet 1 of 5) Page 1 Light and ENGINE START Control Panel (Sheet 2 of 5) Page 2 LIGHT and ENGINE START Control Panel (Sheet 3 of 5) Page 3 LIGHT and ENGINE START Control

More information

Safety and Emergency procedures in LAMP

Safety and Emergency procedures in LAMP Safety and Emergency procedures in LAMP A supplement to the SOP for Laboratory for Advanced Materials Processing JM Patterson Bldg., Room 2225 Revision 1.3 March 31, 2004 Prepared by Laurent Henn-Lecordier,

More information

IJ3000 IJ3000 Flushing System N Revision B Installation Instructions Page 1 of 10

IJ3000 IJ3000 Flushing System N Revision B Installation Instructions Page 1 of 10 IJ3000 IJ3000 Flushing System 5760-029N Revision B Installation Instructions Page 1 of 10!! WARNING: Do not turn on until all plumbing and electrical connections have been made. WARNING: The flushing system

More information

WB Holden Aircondtioning Re-Instalation

WB Holden Aircondtioning Re-Instalation WB Holden Aircondtioning Re-Instalation My Ute has the rudimentary remains of the Airconditioning System in the form of the Evaporator/Heater airbox mounted forward and aft of the firewall. The original

More information

TRAINING BULLETIN September 1, 2010 PURPLE K DRY CHEMICAL EXTINGUISHER 1. INTRODUCTION

TRAINING BULLETIN September 1, 2010 PURPLE K DRY CHEMICAL EXTINGUISHER 1. INTRODUCTION TRAINING BULLETIN September 1, 2010 1. INTRODUCTION Purple K dry chemical extinguishers have been issued to various units of the department. Purple K is a potassium bicarbonate base dry chemical. While

More information

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

ZIOU/230 - MAINS IO INSTRUCTION MANUAL Description ZIOU/230 - MAINS IO INSTRUCTION MANUAL The Mains IO Modules are fully monitored loop powered devices which permit the interfacing of third party equipment with the Fire Alarm Control panel

More information

NGD8800 USER S MANUAL

NGD8800 USER S MANUAL NGD8800 USER S MANUAL COMBUSTIBLE GAS DETECTOR Please read this manual carefully and thoroughly before using this product. CONTENT Page 1. GENERAL INFORMATION ------------------ 2 2. FEATURES -----------------------------------------

More information

Section 11. Heating and Ventilation. Heating & Ventilation Systems. 1 of 6

Section 11. Heating and Ventilation. Heating & Ventilation Systems. 1 of 6 Heating and Ventilation 1 of 6 HEATING AND VENTILATION SYSTEM General Ambient air, drawn in by a fan through a vent in the cowling above the cockpit is mixed with hot air (P2), tapped from the engines,

More information

Helicycle Crew Alerting System (CAS)

Helicycle Crew Alerting System (CAS) Helicycle Crew Alerting System (CAS) CAS Logic Boards Mounted on Radio Trays (Only 3 left as of Aug 14 th.) 8/14/2015 page 1 OF 12 INTRODUCTION If you view my Monterey Bay Shoreline video on YouTube, you

More information

SPECIFICATION FOR A TOTAL FLOOD ECARO-25 TM CLEAN AGENT FIRE SUPPRESSION SYSTEM FOR USE WITH THE SHP PRO CONTROL PANEL SYSTEM

SPECIFICATION FOR A TOTAL FLOOD ECARO-25 TM CLEAN AGENT FIRE SUPPRESSION SYSTEM FOR USE WITH THE SHP PRO CONTROL PANEL SYSTEM SECTION 1 - GENERAL CONDITIONS SPECIFICATION FOR A TOTAL FLOOD I. SCOPE: This specification outlines the requirements for a Total Flood ECARO-25 TM clean agent fire suppression system utilizing HFC-125

More information

OPERATION MANUAL. Move it. Hang it. Rack it. Stack it. MaxPower Corporation 230 Yuma Street Denver, CO

OPERATION MANUAL. Move it. Hang it. Rack it. Stack it. MaxPower Corporation 230 Yuma Street Denver, CO OPERATION MANUAL Complete Instructions for and Operation MaxPower Corporation 230 Yuma Street Denver, CO 80223 800-576-3966 www.coolcube10.com Move it. Hang it. Rack it. Stack it. 05/05 P/N: 5-TC600-2510

More information

XRRS Specification Fire Ready Hood

XRRS Specification Fire Ready Hood XRRS Specification Fire Ready Hood ************************************************************************************************************************ Note to User: This document is subject to copyright

More information

A System That Utilizes the LD-2000 or LD-3000 Mechanical Line Leak Detector to Perform 3 10 PSI (catastrophic) Line Tests

A System That Utilizes the LD-2000 or LD-3000 Mechanical Line Leak Detector to Perform 3 10 PSI (catastrophic) Line Tests Overview of the A System That Utilizes the LD-2000 or LD-3000 Mechanical Line Leak Detector to Perform 3 GPH @ 10 PSI (catastrophic) Line Tests Meet EPA Hourly Test Requirement by Performing Line Tests

More information

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview Water Leak Detector - Four Zone with open/short-circuit detection Product overview The AX-WLDF is a four zone water leak detection module with open or short circuit sensor cable detection. The module must

More information

REVISION NO. 1 DATED SEPT 20/10 HIGHLIGHTS

REVISION NO. 1 DATED SEPT 20/10 HIGHLIGHTS COMPONENT MAINTENANCE MANUAL TO: HOLDERS OF THE FIRE EXTINGUISHER, DUAL OUTLET DUAL BYPASS SYSTEM 70 CUBIC INCH COMPONENT MAINTENANCE MANUAL,, DATED. REVISION NO. 1 DATED SEPT 20/10 HIGHLIGHTS THIS PUBLICATION

More information

automatic FiReFighTing SYSTeMS in PainT booths

automatic FiReFighTing SYSTeMS in PainT booths SPECIAL HAZARDS PROTECTION automatic FiReFighTing SYSTeMS in PainT booths hazard type The risks considered, according to existing regulations, are Class A risk: solids fire. Class B risk: fire of flammable

More information

AUTOMATIC FIREFIGHTING SYSTEMS IN PAINT BOOTHS

AUTOMATIC FIREFIGHTING SYSTEMS IN PAINT BOOTHS SPECIAL HAZARDS PROTECTION AUTOMATIC FIREFIGHTING SYSTEMS IN PAINT BOOTHS Hazard type The risks considered, according to existing regulations, are Class A risk: solids fire. Class B risk: fire of flammable

More information

DASSAULT AVIATION Proprietary Data

DASSAULT AVIATION Proprietary Data F900EX EASY 02-38-00 CODDE 1 PAGE 1 / 2 TABLE OF CONTENTS 02-38 02-38-00 TABLE OF CONTENTS 02-38-05 GENERAL Introduction Sources Equipment location 02-38-10 DESCRIPTION General 02-38-15 CONTROL AND INDICATION

More information

08/17/2011 Rev. 4 PULL STATION EXHAUST HOOD 10 TO 20 FEET FROM HOOD LOCATE ONE NEAR EVERY POINT OF EGRESS FROM HOOD

08/17/2011 Rev. 4 PULL STATION EXHAUST HOOD 10 TO 20 FEET FROM HOOD LOCATE ONE NEAR EVERY POINT OF EGRESS FROM HOOD 24V CORE TOTAL FLOOD PROTECTION INSTALLATION SUMMARY CORE WATER LINE- 30 TO 70 PSI OPERATING PRESSURE, 90 PSI MAX STATIC PRESSURE, 1.5 GPM PER FOOT OF HOOD 3/4 INCH NPT FITTING, CONNECTED TO SUPERVISED,

More information

GERMANY TEC 'LOGY leak-detect EXPERT

GERMANY TEC 'LOGY leak-detect EXPERT GERMANY TEC 'LOGY leak-detect EXPERT WJL-6000 HALOGEN LEAK DETECTOR CUSTOMER MANUAL GE General Information: Incorporated with advanced leak detect technology, WJL-6000 is our new product with the functions

More information

Machine and Power Tool Safety Checklist. Version 1.2 January Chestnut Street, Suite 400, Philadelphia, PA

Machine and Power Tool Safety Checklist. Version 1.2 January Chestnut Street, Suite 400, Philadelphia, PA Machine and Power Tool Safety Checklist Version 1.2 January 2018 3160 Chestnut Street, Suite 400, Philadelphia, PA 19104 215-898-4453 Machine and Power Tool Safety Checklist Overview The purpose of this

More information

H-10PM. Refrigerant Leak Detector

H-10PM. Refrigerant Leak Detector H-10PM Refrigerant Leak Detector Congratulations! You have just purchased the most versatile, high performance service leak detector available in the industry today. It will detect refrigerants with a

More information

INSTALLATION AND PROGRAMMING MANUAL

INSTALLATION AND PROGRAMMING MANUAL INSTALLATION AND PROGRAMMING MANUAL Contents Section 0. Section 1. Section 2. Section 3. Section 4. Section 5. Section 6. Section 7. Section 8. Section 9. Section 10. Section 11. Section 12. Section 13.

More information

Fire. IMO fire control signs - according to IMO Resolution A.654 (16) (mm) 150x x200

Fire. IMO fire control signs - according to IMO Resolution A.654 (16) (mm) 150x x200 IMO fire control signs - according to IMO Resolution A.654 (16) Safety and operating instructions for trained personnel (SIS) - As per ISO 24409, SIS signs are safety-related signs that replicate the symbols

More information

1 Aviation English Vocabulary Level 4 to 5

1 Aviation English Vocabulary Level 4 to 5 1 Aviation English Vocabulary Level 4 to 5 Vocabulary: Engine Fire Describe the photograph. Try to speak for at least 30 seconds. Match the words to make a noun adjective or verb. eg fire extinguisher

More information

Restek s Electronic Leak Detector

Restek s Electronic Leak Detector Restek s Electronic Leak Detector (cat.# 22839) Instruction Manual 2008 Restek Corporation No part of this manual may be reproduced in any form or by any means without the prior agreement or permission

More information

Canadair Regional Jet 100/200 - Water & Waste

Canadair Regional Jet 100/200 - Water & Waste INTRODUCTION The water and waste systems include potable water, lavatory waste equipment and system controls. Two potable water systems store and supply potable water to the galley and lavatory. The forward

More information

Explosion Venting and Suppression of Bucket Elevator Legs, G90-990

Explosion Venting and Suppression of Bucket Elevator Legs, G90-990 Page 1 of 6 G90-990 Explosion Venting and Suppression of Bucket Elevator Legs Explosion vents and explosion suppression devices limit the danger and damage associated with grain dust explosions. This NebGuide

More information

PROENGIN INC. RETAIL PRICE LIST

PROENGIN INC. RETAIL PRICE LIST PROENGIN INC. RETAIL PRICE LIST Estimated Delivery Times: AP2C 3weeks on receipt of signed NTC AP4C 6 weeks on receipt of signed NTC PL/ARM/2011-2012 Plantation FL 33324 1 of 7 HANDHELD DETECTORS M266

More information

CESCOM 20 - Projected Maintenance Due

CESCOM 20 - Projected Maintenance Due Date Average Projected Days Months Scheduled Maintenance Tasks Drawing # / Task # City Mod Lvl Part Number Part Serial No 51211 PHASE 11 051211 LEFT 051208 : L RIGHT 051208 : R 5120B 051200B INSPECT INBOARD

More information

Alert-3 LCD Alarm v2.0

Alert-3 LCD Alarm v2.0 Operating & Maintenance Manual Alert-3 LCD Alarm v2.0 1ST FLOOR ROOM 12 2ND FLOOR ROOM 25 3RD FLOOR ROOM 37 MAINTEN EXT 302 4TH FLOOR ROOM 47 5TH FLOOR ROOM 58 w w w. a m i c o. c o m Contents User Responsibility

More information

Environmental Systems

Environmental Systems Environmental Systems 21-00: ENVIRONMENTAL SYSTEMS 1. General This section covers those systems and components used to furnish a means of heating, cooling, and treating the air used to ventilate the areas

More information

Air Check O 2 Sample Draw Monitor

Air Check O 2 Sample Draw Monitor Air Check O 2 Sample Draw Monitor Instruction Manual PureAire Monitoring Systems, Inc. 557 Capital Drive Lake Zurich, Illinois 60047 Phone: 847-726-6000 Fax: 847-726-6051 Toll-Free: 888-788-8050 pureairemonitoring.com

More information

Advance Optima Continuous Gas Analyzers AO2060-Caldos15, -Caldos17, -Magnos106, -Uras14 Category 2G Analyzer Modules

Advance Optima Continuous Gas Analyzers AO2060-Caldos15, -Caldos17, -Magnos106, -Uras14 Category 2G Analyzer Modules Advance Optima Continuous Gas Analyzers AO2060-Caldos15, -Caldos17, -Magnos106, -Uras14 Category 2G Analyzer Modules Operator s Manual 42/24-12 EN Rev. 4 Contents Page Preface 4 Safety Information General

More information

control sequences model QST / EST Series Table 47: QST / EST Analog Electronic Control Strategies Fan Powered Air Terminals

control sequences model QST / EST Series Table 47: QST / EST Analog Electronic Control Strategies Fan Powered Air Terminals control sequences Table 47: QST / EST Analog Electronic Control Strategies Control Package Number QST EST FS-A-5000 FSE-A-5000 FS-A-5001 FSE-A-5001 FS-A-5002 FSE-A-5002 FS-A-5003 FSE-A-5003 FS-A-5004 FSE-A-5004

More information

Project Name: Project Address: Installer Name: Installer Address: Date of Inspection:

Project Name: Project Address: Installer Name: Installer Address: Date of Inspection: FIRE DEPARTMENT Kitchen Range Hood Fire Suppression System Acceptance Test Project Name: Project Address: Installer Name: Installer Address: Date of Inspection: DOCUMENTATION NO Plans have been reviewed

More information

TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION SPECIFICATIONS APPROVALS TYPE NM

TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION SPECIFICATIONS APPROVALS TYPE NM TTC-1 TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION The nvent RAYCHEM TraceTek TTC-1 sensing module is used with TraceTek sensing cables to detect liquid leaks.

More information

A. CHECK THAT THE FLEXIBLE GAS CONNECTOR HAS BEEN REPLACED BETWEEN THE MANIFOLD AND THE BURNER.

A. CHECK THAT THE FLEXIBLE GAS CONNECTOR HAS BEEN REPLACED BETWEEN THE MANIFOLD AND THE BURNER. BulkTobac A DIVISION OF GAS-FIRED PRODUCTS, INC. 305 Doggett Street, P.O. Box 36485 Charlotte, NC 28236 Phone: (704) 372-3485 Toll Free: (800) 830 3983 Fax: (704) 332-5843 To: Roanoke HeatX Conversion

More information

Agent Dissemination Devices

Agent Dissemination Devices Module 6 Dissemination Devices Overview 1 Objectives Student will be able to identify a potential CBRNE dissemination devices categorize a dissemination device as to type and potential impact. identify

More information

INSTALLATION AND OPERATION MANUAL ISM-4081 INTEGRATED SHUTDOWN MODULE

INSTALLATION AND OPERATION MANUAL ISM-4081 INTEGRATED SHUTDOWN MODULE INSTALLATION AND OPERATION MANUAL ISM-4081 INTEGRATED SHUTDOWN MODULE SYSTEM CONCEPT When not transferring fuel, the pressure in the underground piping system for gasoline distribution may fall due to

More information

SPECIFICATION: ECS SERIES CLEAN AGENT FIRE SUPPRESSION SYSTEM

SPECIFICATION: ECS SERIES CLEAN AGENT FIRE SUPPRESSION SYSTEM 1. GENERAL SPECIFICATION 1.1. A total flooding, FM-200 fire suppression system, super-pressurized with dry nitrogen shall be installed to meet a minimum design concentration of %, by volume in all designated

More information