RM Smoke Detector

Size: px
Start display at page:

Download "RM Smoke Detector"

Transcription

1 RM Smoke Detector with RS 3000 Relay Base for Hold-Open Systems DICTATOR RM smoke detectors and WM heat detectors are used hold-open systems to automatically close fire protection doors the event of alarm. RM optical smoke detectors work on the prciple of photo-electric detection of scattered light with usg any radioactivity. To ensure maximum reliability, three consecutive sensed alarm signals are needed to trigger alarm and to switch off the power supply to the hold-open magnets on the door. The WM heat detector comprises a pair of matched heat detectors. One of them is exposed and therefore responds quickly to changes air temperature, whereas the second one is sulated and responds more slowly. The relay cuts off the power supply when a certa temperature is reached or the event of a rapid crease the temperature of the surroundg air. The detectors of this series comply with the European Standard EN 54. They have been tested as trippg devices for hold-open systems and are approved together with DICTATOR electromagnets by the buildg authorities. The detectors are among others cluded the followg approvals: Z , Z Technical Data Voltage supply 9 to 33 VDC Power consumption 25 ma at 24 V; 62 ma on alarm Operatg temperature (smoke detector) -20 C to +60 C (prevent icg) Alarm temperature (heat detector) +60 C; other temperatures on request Breakg capacity of contacts 1 A at 24 VDC Contact voltage 50 V (max) Contact current 1 A (non ductive) IP ratg IP 54 (heat detector), IP 43 (RM 3000+) Tel. +49(0) Fax +49(0) fo@dictator.de 1027 Page

2 Dimensions All detectors of the range fit to the RS 3000 relay base, i.e. if necessary, smoke detectors can be replaced with a heat detector from the range. However, please always observe durg stallation the relevant regulations concerng the arrangement of detectors on opengs walls of the respective approval of the buildg authorities. To protect the sensg chamber from pollution durg construction work, all detectors are delivered with a red protection cap which must be removed when the hold-open system is put to operation. To facilitate the stallation of detectors suspended ceilgs, a special base with a mountg bar (part no ) is available. 1. Optical Smoke Detector ø100 ø Heat Detector RS 3000 Relay Base 4,5 The two slots the base make it very easy to stall as precise fixg holes the ceilg are not required Spare The wide terior diameter of the bases the 3000 range allows for ease of access to wires and the five termals. Wirg is possible both from the back or from the side (knock-s the base). L2 -R The detector is plugged by turng it clockwise. An anti-theft feature is cluded. A missg detector means alarm. Page Tel. +49(0) Fax +49(0) fo@dictator.de 1027

3 RM Smoke Detector, WM Heat Detector Easy to Connect, with Integrated Relay Connect the required number of smoke detectors (see the respective relevant approval of the buildg authorities) to one of our power packs. When choosg the power pack please make sure that the total power consumption of all connected detectors does not exceed the supply current of the power pack. These smoke detectors consume maximum 62 ma the event of alarm. The hand switch needs to be placed the wirg to the first detector. The electrical hold-open magnets are connected to the last detector the detector circuit. This allows for a simple, lear wirg. Wirg Diagram for Sgle Detector Power pack 230 VAC Hand switch 24 VDC L2 -R RM or WM with RS 3000 relay base Hold-open devices: Electromagnets, door closers or door operators Wirg Diagram for Three Detectors 230 VAC Hand switch 24 VDC L2 -R L2 -R L2 -R Power pack RM or WM with RS 3000 relay base Hold-open devices: Electromagnets, door closers or door operators If you need to stall more than 3 detectors, simply place them with the circuit. The power pack and hand switch must always be connected to the first detector, and the hold-open magnets must be wired to the relay base of the last detector the circuit. DICTATOR electromagnets and door operators are provided with the necessary spark extction diode as standard. If the base relay switchable load is not sufficient, you need to connect an additional relay. We will be happy to provide the necessary formation. Attention:The functiong of hold-open systems must be tested every month - provided no other period is given the approval document - and they require annual mataance by authorized personnel. IMPORTANT: after an alarm a RESET is necessary. This can be done either by pressg the hand switch or by removg the detector from the relay base and screwg it back aga. Tel. +49(0) Fax +49(0) fo@dictator.de 1027 Page

4 RM Smoke Detector, WM Heat Detector DICTATOR smoke detectors and DICTATOR heat detectors are equipped with an tegrated relay the base. This switches off electromagnets, door closers or door operators the event of fire. The doors then close automatically. Important for matenance services: the maximum allowable delay respondg of the detector are 39 seconds. IMPORTANT: the detectors must be protected from icg and condensation. Installation and Function The relay base can directly be fitted to the ceilg. The detector is plugged to the base and secured by turng clockwise. When mountg it on a wall, a mountg bracket has to be used to make sure the detector is always a horizontal position. Order Information RM smoke detector WM heat detector (alarm temperature 60 C) Heat detectors with other alarm temperatures (no approval) part no N part no N on request Accessories Base with relay and evaluation electronics part no Further Accessories Power packs (450 ma, 800 ma) see page Electromagnets for stallation on wall/ceilg/floor see page Hand switch for manual release of door see page Sequence controllers see page Automatic and semi-automatic door operators see page N or 320 N sprg rope pulley or counterweight see page Hydraulic radial dampers and fal dampers see page Page Tel. +49(0) Fax +49(0) fo@dictator.de 1027

5 Mountg Bracket for RM 2000, RM and WM The mountg bracket (part no ) allows DICTATOR smoke and heat detectors to be fixed to the wall with difficulty. The fixg holes are suitable for both the RM 2000 and RM 3000+/WM range. Accordg to the demands of the Deutsches Institut für Bautechnik Berl regardg the stallation of fire detectors, exceptional cases it is allowed to replace a detector on the ceilg by a detector on the wall (see page et sqq.). However, the horizontal distance between the wall and the axle of the detector must be 0.5 m. The mountg bracket, part no meets this demand. All fixg holes correspond to those of the bracket part no Dimensions 25 Mountg bracket part no , ,5 23 8, , , , Mountg bracket part no Order Information Bracket for stallation on the wall (RM 2000/RM 3000+) part no Bracket for stallation on the wall, length of the arm 550 mm part no Tel. +49(0) Fax +49(0) fo@dictator.de 1027 Page

6 Page Tel. +49(0) Fax +49(0)

RM Smoke Detector

RM Smoke Detector RM 3000+ Smoke Detector with RS 3000 Relay Base for Hold-Open Systems DICTATOR RM 3000+ smoke detectors and WM 3000+ heat detectors are used hold-open systems to automatically close fire protection doors

More information

Fire Door Control Solutions

Fire Door Control Solutions Fire Door Control Solutions Contents Fire Door Control Solutions Smoke Detectors Pages 07.003.00-07.018.00 Power Packs Control of Signals Ex-Proof Hold-Open Systems Pages 07.019.00-07.030.00 Electromagnets

More information

DICTATOR Hold-Open Systems for Hazardous Areas

DICTATOR Hold-Open Systems for Hazardous Areas DICTATOR for Hazardous Areas Products to be used in hazardous areas obviously have to meet special demands. The European ATEX directives (first the EN 94/9/EG and then the directive 2014/34/ EU) brought

More information

RECOGNIZE THIS SYMBOL AS AN INDICATION OF IMPORTANT SAFETY INFORMATION!

RECOGNIZE THIS SYMBOL AS AN INDICATION OF IMPORTANT SAFETY INFORMATION! REV. /4 TJERNLUND PRODUCTS, INC. 6 Nth Street White Bear Lake, MN 55-6794 PHONE (8) 55-48 (65) 46-99 FAX (65) 46-9547 Visit our web site www.tjernlund.com AUTO-DRAFT VSUB-SERIES VSUB BLOWERS For providg

More information

Installation of the Indoor Unit

Installation of the Indoor Unit stallation of the door Unit Firmly secure the evaporator mountg plate on a wall strong enough to withstand the weight of the unit. The plate must be level and allow for the clearances shown the figure

More information

Owner s Manual. VFH-B Series. Inverter Multi Zone Ductless Mini-Split A-VFH30QB-1 A-VFH36QB-1 A-VFH42PB-1.

Owner s Manual. VFH-B Series. Inverter Multi Zone Ductless Mini-Split A-VFH30QB-1 A-VFH36QB-1 A-VFH42PB-1. Owner s Manual VFH-B Series Inverter Multi Zone Ductless Mi-Split A-VFH30QB-1 A-VFH36QB-1 A-VFH42PB-1 www.marsdelivers.com In le with the MARS policy of contual product improvement, the aesthetic and dimensional

More information

TS 93. Cam action door closer system in Contur Design

TS 93. Cam action door closer system in Contur Design TS 9 Cam action door closer system in Contur Design VERSATILE AND ELEGANT The TS 9 cam action door closer system provides a high-quality architectural solution for all project application requirements.

More information

Half Round Evaporators

Half Round Evaporators PRODUCT DATA & INSTALLATION Bullet T30-T-PDI-18 Part # 1047129 PRODUCT SUPPORT web: t-rp.com/truc email: evaps@t-rp.com call: 1-844-893-3222 x520 scan: Half Round Evaporators High Temperature Applications

More information

Arieta. Architectural LED Area Luminaires AR13, AR18

Arieta. Architectural LED Area Luminaires AR13, AR18 Arieta Architectural LED Area Lumaires AR13, Area lightg for parkg lots, campuses, office complexes, streets, bicycle paths, and public parks www.leotek.com Numerous Applications High Performance. Elegant

More information

Conventional Smoke Detectors KFAPO

Conventional Smoke Detectors KFAPO Kingfisher Company, inc. Conventional Smoke Detectors KFAPO Features: Wide operating voltage, 9-33 VDC Advanced electronic technology Flashing LED Magnetic test switch Proven detection performance Designed

More information

Cam action door closer system DORMA TS 93

Cam action door closer system DORMA TS 93 Cam action door closer system DORMA TS 93 reddot design award winner 200 DORMA TS 93 Cam action door closer system DORMA TS 93 Cam action door closer system TS 93 G-SR-EMR Versatile and elegant The TS

More information

FOR INSTRUCTION VIDEOS PLEASE VISIT Visit Bestway YouTube channel TO THE STORE

FOR INSTRUCTION VIDEOS PLEASE VISIT   Visit Bestway YouTube channel TO THE STORE TO THE STORE QUESTIONS? PROBLEMS? MISSING PARTS? For FAQ, Manuals Or Spare Parts, Please Visit www.bestwaycorp.com www.bestwaycorp.com Visit Bestway YouTube channel FOR INSTRUCTION VIDEOS PLEASE VISIT

More information

Series 65 Product Guide MAN 3036

Series 65 Product Guide MAN 3036 Series 65 Product Guide MAN 3036 TABLE OF CONTENTS Page No. 1 Ionisation Smoke Detector... 1 1.1 Operating Principles:... 1 1.2 Product Codes... 2 1.3 Integrating Version:... 2 1.4 Options:... 2 1.5 Safety

More information

POLOCOOL. Whisper USER MANUAL. 10,000 BTU (2.9kW) PORTABLE REFRIGERATED AIR CONDITIONER. For AUGUST 2017

POLOCOOL. Whisper USER MANUAL. 10,000 BTU (2.9kW) PORTABLE REFRIGERATED AIR CONDITIONER. For AUGUST 2017 AUGUST 2017 PORTABLE REFRIGERATED AIR CONDITIONER USER MANUAL For POLOCOOL Whisper PQ10 10,000 BTU (2.9kW) Thank you selectg our quality air conditioner. Please be sure read this user manual carefully

More information

TS 93. Cam action door closer system in Contur Design

TS 93. Cam action door closer system in Contur Design TS 93 Cam action door closer system in Contur Design dormakaba TS 93 Versatile and elegant The TS 93 cam action door closer system provides a high-quality architectural solution for all project application

More information

Installation instructions for the optical detector with built-in control unit, TBLZ-1-72-a GOLD/COMPACT

Installation instructions for the optical detector with built-in control unit, TBLZ-1-72-a GOLD/COMPACT Installation instructions for the optical detector with built-in control unit, TBLZ-1-72-a GOLD/COMPACT 1. General The TBLZ-1-72-a optical smoke detector with built-in control unit is used for measuring

More information

Call for more information RP-QM72/QMT72 page 644. RP-LS42 page 643. RP-RM83 page 642

Call for more information RP-QM72/QMT72 page 644. RP-LS42 page 643. RP-RM83 page 642 Rope Switches Models that comply with cable break/slack detection with manual reset for Emergency Stop applications Available spans range from 6 to 1 m Trip and latch switch models are available Mimum

More information

ISC-PDL1-W18G-H. Installation Instructions Professional Series Dual Detector

ISC-PDL1-W18G-H. Installation Instructions Professional Series Dual Detector ISC-PDL1-W18G-H EN Installation Instructions Professional Series Dual Detector 1.0 General Information 1.1 Unlock and remove the cover The ISC-PDL1-W18x Professional Series TriTech Detectors are exceptionally

More information

8600 EMR SERIES. INSPK NO Rev.06/ INS NO. GENERAL DESCRIPTION

8600 EMR SERIES. INSPK NO Rev.06/ INS NO. GENERAL DESCRIPTION 00 EMR SERIES GENERAL DESCRIPTION Each 00 EMR series unit contains a door closer, hold open electromagnet and smoke detector. The unit can be used as a single installation or as a series of singles powered

More information

TRX MAINS CONNECTION DIAGRAM

TRX MAINS CONNECTION DIAGRAM TRX MAINS CONNECTION DIAGRAM Switch 230VAC 10A Neutral Out Phase Out TRX MAINS Phase In Neutral In LOAD 8A MAX. Specifications: Operating Voltage: 220-240VAC 50Hz Current Draw: 5mA Max. Switching Current:

More information

6 5 0 E X WJ-SX650 WJ-SX650U

6 5 0 E X WJ-SX650 WJ-SX650U Matrix System50EX Matrix System 50EX. Enhancg Large-System Surveillance. cameras and 4 monitors, plus up to 4-doma Satellite capability The new Panasonic Matrix System50EX redefes "advanced" large-system

More information

5, SE GÅNGHESTER,

5, SE GÅNGHESTER, KSUB Control and monitoring unit Valid from week of manufacture 48/2005 Description The KSUB is a control and monitoring unit designed to control various types of fire/smoke dampers and fans in a flexible

More information

ABLOY FIRE DOOR CLOSING SYSTEMS

ABLOY FIRE DOOR CLOSING SYSTEMS FIRE DOOR CLOSING SYSTEMS Maximum security An ASSA ABLOY Group brand FIREDOOR CLOSING SYSTEMS Maximum security and easy access ABLOY high security products are well known and highly respected all over

More information

Ç Consilium Consilium US, Inc. 59 Porter Rd Littleton, MA USA

Ç Consilium Consilium US, Inc. 59 Porter Rd Littleton, MA USA INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX BACKUP PUMP CONTROL SYSTEM MODEL NUMBER BPC-3 November 22, 1999 Ç Consilium Consilium US, Inc. 59 Porter Rd Littleton, MA 01460-1431 USA Telephone:

More information

OH110, OP110, HI110 Automatic fire detectors

OH110, OP110, HI110 Automatic fire detectors OH110, OP110, HI110 Automatic fire detectors For collective and conventional detector lines Signal processing with detector algorithms Selectable parameter sets 3 color LED indication Drift compensation

More information

Emergi-Lite Orbis detectors

Emergi-Lite Orbis detectors Emergi-Lite Orbis detectors Emergi-Lite Orbis brings the latest in fire detector microprocessor technology to the Firetec and Eurofire systems. Non-addressable (conventional) smoke and heat sensors respond

More information

Installation, Operating and Maintenance Manual

Installation, Operating and Maintenance Manual STATUS ZONES CONTROLS FIRE FAULT DISABLED FIRE 1 2 3 4 5 6 7 8 TEST FAULT DISABLED 1 5 BUZZER SILENCE RESET 1 2 TEST 2 6 LAMP TEST 3 SUPPLY 3 7 SYSTEM FAULT 4 8 SOUNDERS ACTIVATE/ SILENCE 4 FAULTS INSTRUCTIONS

More information

DT1101A / DT1102A / DO110xA Automatic fire detectors

DT1101A / DT1102A / DO110xA Automatic fire detectors DT1101A / DT1102A / DO110xA Automatic fire detectors collective/synoline600 AlgoRex Synova High degree of reliability and stability Compatible with all control units with collective/synoline600 detector

More information

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

FIREBETA EXTINGUISHING CONTROL PANEL (ECP) F I R E D E T E C T I O N A N D C O N T R O L FIREBETA EXTINGUISHING CONTROL PANEL (ECP) Three versions: 2 areas of detection and 1 area extinguishing 4 areas of detection and 1 area extinguishing 4 areas

More information

OPTISENS TUR 2000 Technical Datasheet

OPTISENS TUR 2000 Technical Datasheet OPTISENS TUR 2000 Technical Datasheet Sensor for turbidity measurement in water and wastewater Rugged design for harsh applications Integrated transmitter with direct 4...20 ma output Near infrared light

More information

English. Series. Installation and Use Manual

English. Series. Installation and Use Manual English Series FOSTER Installation and Use Manual FOSTER Rev.13 03/2015 MITECH srl reserves the right to change the information in this document without warning. Index Anti-intrusion barrier 3 Main components

More information

Ventilation improvement in fire smoke control

Ventilation improvement in fire smoke control Environmental Health Risk II 41 Ventilation improvement fire smoke control L. Santarpia, F. ugliermetti &. Zori Department of Fisica Tecnica, Rome University La Sapienza, Italy Abstract Thermal gradients,

More information

ABLOY DOOR CLOSERS Exactly the right choice

ABLOY DOOR CLOSERS Exactly the right choice DOOR CLOSERS Exactly the right choice An ASSA ABLOY Group brand DOOR CLOSERS Superior performance and reliability ABLOY high security products are known and highly respected all over the world. Every item

More information

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS QUICK USER GUIDE FOR, 2 & 4 ZONE PANELS INDICATORS COLOUR INDICATION MON FAULT Yellow On when a fault condition has occurred, or if no other fault Led is on, this indicates 24v auxiliary fuse failure.

More information

POWERPATH PS-8 (105531) PS-8E (100263) PS-6 (105530) PS-6E (100262)

POWERPATH PS-8 (105531) PS-8E (100263) PS-6 (105530) PS-6E (100262) PATH PS-8 (105531) PS-8E (100263) PS-6 (105530) PS-6E (100262) NAC ETENDER SUPPLIES Installation Instructions 273 Branchport Avenue, Long Branch, NJ 07740-6899 Ph: (800) 631-2148 Fax: (732) 222-8707 Web

More information

ANSUL AUTOMAN II-C EXPLOSION PROOF RELEASING DEVICE Installation, Operation, and Maintenance Manual

ANSUL AUTOMAN II-C EXPLOSION PROOF RELEASING DEVICE Installation, Operation, and Maintenance Manual ANSUL AUTOMAN II-C EXPLOSION PROOF RELEASING DEVICE Installation, Operation, and Maintenance Manual 001799 This manual is intended for use with the ANSUL AUTOMAN Il-C Explosion-Proof Releasing Device.

More information

Conventional Detectors

Conventional Detectors Conventional Detectors ECO1000 The world s finest manufacturing facility Sensor s European products are researched, designed and manufactured at our 10,000m2 state-of-the-art facility in Trieste, Italy.

More information

Air Specialties Express, 448 S. Main St., P. O. Box , Verona, WI Phone: (877) Fax: (608)

Air Specialties Express, 448 S. Main St., P. O. Box , Verona, WI Phone: (877) Fax: (608) FORM ASX-40020 INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS SL-2000 Series Smoke Detectors, Model EXSAA and EXSAB (Ionization), EXSAG and EXSAH (Photoelectric) Air Specialties Express, 448 S. Main

More information

Addressable Detectors & Bases

Addressable Detectors & Bases Edwards Signaling Catalog u Intelligent Initiating Addressable Detectors & Bases Detectors: E-PD, E-PHD, E-HD Bases: B4U, RB4U, IB4U, SB4U Overview Edwards intelligent addressable detectors are meticulously

More information

Sub 6 Owner s manual. Hello Welcome to Dynaudio Sub 6 High-end low end: true Dynaudio performance

Sub 6 Owner s manual. Hello Welcome to Dynaudio Sub 6 High-end low end: true Dynaudio performance Sub 6 Owner s manual Hello Welcome to Dynaudio Sub 6 High-end low end: true Dynaudio performance This is Sub 6 6 Introduction 8 Important safety structions 10 Ab this manual 11 Safety Icons Hello 11 Signal

More information

Table 1: Attenuation Rating Switch Position. Position Attenuation (db) Attenuation (db) (Approx.)

Table 1: Attenuation Rating Switch Position. Position Attenuation (db) Attenuation (db) (Approx.) Branchport Ave. Long Branch, N.J. () www.wheelockinc.com Thank you for using our products. STALLATION STRUCTIONS SPSVC SAFEPATH SUPERVISED VOLUME CONTROL Use this product according to this instruction

More information

OOH740, OOHC740 Automatic fire detectors

OOH740, OOHC740 Automatic fire detectors OOH740, OOHC740 Automatic fire detectors ASAtechnology TM For the automatic addressable detector bus C-NET Collective / Conventional (OOH740 only) Cerberus PRO Signal processing with ASAtechnology TM Event-controlled

More information

ABLOY DOOR CLOSERS Excatly the right choice

ABLOY DOOR CLOSERS Excatly the right choice DOOR CLOSERS Excatly the right choice DOOR CLOSERS Superior performance and reliability ABLOY high security products are known and highly respected all over the world. Every item in our wide product range

More information

RMS-I-DE-01 Smoke Detector

RMS-I-DE-01 Smoke Detector RMS-I-DE-01 Smoke Detector 2012 CONTEG, spol. s r.o. All rights reserved. No part of this publication may be used, reproduced, photocopied, transmitted or stored in any retrieval system of any nature,

More information

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series 670 Hood Monitor. Bulletin AV-670

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series 670 Hood Monitor. Bulletin AV-670 Bulletin AV-670 Series 670 Hood Monitor Specifications - Installation and Operating Instructions DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Phone: 219/879-8000 Fax: 219/872-9057

More information

Hot Work Permits. Corporate Environment Safety & Health

Hot Work Permits. Corporate Environment Safety & Health Cpate Environment Safety & Health 1 Why are we here? Every year fires occur, which could have been prevented had employees used appropriate fire prevention measures. Th company requires the use the Hot

More information

MULTISENSOR SMOKE AND HEAT DETECTOR DMP-100 OPTICAL SMOKE DETECTOR DRP-100 FIXED TEMPERATURE / RATE-OF-RISE HEAT DETECTOR DCP-100

MULTISENSOR SMOKE AND HEAT DETECTOR DMP-100 OPTICAL SMOKE DETECTOR DRP-100 FIXED TEMPERATURE / RATE-OF-RISE HEAT DETECTOR DCP-100 MULTISENSOR SMOKE AND HEAT DETECTOR DMP-100 OPTICAL SMOKE DETECTOR DRP-100 FIXED TEMPERATURE / RATE-OF-RISE HEAT DETECTOR DCP-100 Installation Manual dmp-100_en 06/15 SATEL sp. z o.o. ul. Budowlanych 66

More information

Water-Cooled Screw Chillers and Water/Water Heat Pumps

Water-Cooled Screw Chillers and Water/Water Heat Pumps Water-Cooled Screw Chillers and Water/Water Heat Pumps Model RTWD Water-Cooled Model RTUD Condenserless 240-1005 kw RLC-PRC035G-GB Table of Contents Introduction...3 Features and Benefits...4 Application

More information

Knürr RMS Compact II. Knürr RMS Compact II 2.81

Knürr RMS Compact II. Knürr RMS Compact II 2.81 Knürr RMS Compact II Knürr RMS Compact II 2.82 to 2.85 2.81 Knürr RMS Compact II Damage prevention with checks and controls System and network management requirements mean the systems ambient conditions

More information

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator TECHNICAL GUIDE Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator The XPlorer Range XPlorer is a new range of analogue addressable detectors and interfaces developed for all who

More information

Installation and Operation Manual

Installation and Operation Manual [Please read this installation & operation manual before install and use this Installation and Operation Manual Address: 8-701,Dongfangming Industry Zone, Dabao Road., Baoan, Shenzhen, China-518101 Page

More information

DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel

DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel DS3MX-E-I EN Installation Guide 3 Mini Control Panel DS3MX-E-I Installation Guide 1.0 General Information EN 2 1.0 General Information The DS3MX is a three zone mini control panel, which can be installed

More information

TS93 EMR WITH SMOKE DETECTOR

TS93 EMR WITH SMOKE DETECTOR TS EMR WITH SMOKE GENERAL DESCRIPTION Each TS EMR series unit contains a door closer, hold open electromagnet and smoke detector. The unit can be used as a single installation or as a series of singles

More information

Analogue addressable devices

Analogue addressable devices Apollo XP95 Analogue addressable devices from Channel Safety Systems Apollo XP95 Analogue addressable devices The XP95 range of analogue addressable fire detectors is advanced in design, improved in performance

More information

MODEL /4" Conduit. (By others) Terminal Strips Companion unit (without electronics) not shown. Approximate Preload

MODEL /4 Conduit. (By others) Terminal Strips Companion unit (without electronics) not shown. Approximate Preload 2900 FIREGUARD Electromechanical Closer-Holder Device Models 12-2960, 9-2960 and 2960 Multipoint Hold Open with Rigid Arms Pull (Hinge) Side Installation Instructions CAUTION: FAILURE TO INSTALL OR ADJUST

More information

Commercial Water Heaters

Commercial Water Heaters ommercial Water Heaters Sales/ustomer Service or product sales and order quiries, contact us at: Tel: 1-888-599-2837 ax: 1-519-787-5500 Technical Support or prompt service concerng technical support and

More information

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR ED820 24V MODEL fire DETECTOR INSTRUCTION MANUAL Address: Enigma House, Enigma Business Park, Malvern, Worcestershire, WR14 1GD Tel: 44 (0)1684 891500 Fax: 44 (0)1684 891600 Email: sales@electronicdevices.co.uk

More information

Door Release Power Supply

Door Release Power Supply www.protectingpeople.co.uk Door Release Power Supply Engineer / Installation Manual Document: VI55.1 Protecting People Printed : 04/03/2004-1 - Ventcroft Ltd Door Release Power Supply Engineer / Installation

More information

SECURITRON MODEL DPA-12 AND DPA-24 DOOR PROP ALARM TIMERS INSTALLATION AND OPERATING INSTRUCTIONS

SECURITRON MODEL DPA-12 AND DPA-24 DOOR PROP ALARM TIMERS INSTALLATION AND OPERATING INSTRUCTIONS Securitron Magnalock Corp. Tel 775.355.5625 550 Vista Boulevard Fax 775.355.5633 Sparks, NV 89434 info@securitron.com www.securitron.com ASSA ABLOY, the global leader in door opening solutions SECURITRON

More information

INFRARED MODULATED BARRIERS

INFRARED MODULATED BARRIERS INFRARED MODULATED BARRIERS riello elettronica group INFRARED BARRIERS WITH ADJUSTABLE LENSES FULL FULL SYNCRO POWER SUPPLY 12/24 Vac-dc MAXIMUM RANGE UNDER IN CONDITIONS 15 METRES CONFORMS TO THE SAFETY

More information

FAAST. Fire Alarm Aspirating Sensing Technology

FAAST. Fire Alarm Aspirating Sensing Technology FAAST Fire Alarm Aspirating Sensing Technology The FAAST range FAAST 8100e FAAST LT PipeIQ Next Generation Aspiration Detection Detection for Challenging Environments 3 in 1 Design, Confi guration and

More information

Instruction Manual. Electronic gas and smoke detector GRM

Instruction Manual. Electronic gas and smoke detector GRM Mess-, Regel- und Überwachungsgeräte für Haustechnik, Industrie und Umweltschutz Lindenstraße 20 DE-74363 Güglingen Telefon +49(0)7135-102-0 Service +49(0)7135-102-211 Telefax +49(0)7135-102-147 E-Mail

More information

TX7130. Conventional Reflective Beam Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

TX7130. Conventional Reflective Beam Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved. TX7130 Conventional Reflective Beam Detector Installation and Operation Manual Technology Copyright 2015, All right reserved. Product Safety To prevent severe injury and loss of life or property, read

More information

LF Readout Displayed on LED. Compressor Stops Fan Runs. 1 Hour Time INFORMATION. Delay Activates

LF Readout Displayed on LED. Compressor Stops Fan Runs. 1 Hour Time INFORMATION. Delay Activates G. OPERATIONAL SEQUENCE & TROUBLESHOOTG CHART 220V Power To Heater Green Power Light On Possible Bad T-Stat Board, Pot or Sensor Heater Stays Off Water Pump Timer Activates T-Stat Relay Does Not Close

More information

More Precision. indusensor // Linear inductive displacement sensors

More Precision. indusensor // Linear inductive displacement sensors More Precision indusensor // Linear inductive displacement sensors 18 Long-stroke sensors for hydraulics & pneumatics indusensor EDS - Measurement ranges 75... 630mm - Linearity ±0.3% FSO - Integrated

More information

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm.

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm. E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0E FL0E FL0E mm mm 0 mm DESCRIPTION The LT FL0 Series is part of the Fire Alarm Aspiration

More information

Control Panel Engineering and Commissioning Instructions

Control Panel Engineering and Commissioning Instructions Twinflex - V3 Fire Detection & Alarm System Control Panel Engineering and Commissioning Instructions (TO BE RETAINED BY THE COMMISSIONING ENGINEER) 26-0338 Issue 9 Fike s policy is one of continual improvement

More information

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation Sinteso Cerberus PRO FDA241, FDA221 ASD Aspirating smoke detector Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation Patented technology Early

More information

DIGITAL ALARM UNIT Model ALU-AP

DIGITAL ALARM UNIT Model ALU-AP DIGITAL ALARM UNIT Model ALU-AP Description Digital alarm unit ALU-AP has the following characteristics: 1. Operates in MASTER or SLAVE mode. 2. It can connect with other devices through a RS485 network

More information

Dimensions. Model Number 123. Electrical connection. Features. Indicators/operating means. Product information RMS-G-RC-NA.

Dimensions. Model Number 123. Electrical connection. Features. Indicators/operating means. Product information RMS-G-RC-NA. Dimensions ø.7 9.5 6.5 8.5 ø.7 65 57 Window for LED display Model Number Radar sensor Features Industrial gate opener with the ability to differentiate between people and vehicles Extra-wide detection

More information

A series of technical features make this gas detector extremely versatile, reliable, accurate, and safe.

A series of technical features make this gas detector extremely versatile, reliable, accurate, and safe. Belonging to Made in Italy GS911K Gas Detector GS911K Using the catalytic sensor inside it, the GS911K detector detects the presence of explosive gas such as: Methane, LPG, with trip sensitivity calibrated

More information

Honeywell SLATE ICM Platform

Honeywell SLATE ICM Platform Honeywell SLATE ICM Platform SUBMITTAL SPECIFICATION Note to specifiers: To specify Honeywell SLATE Integrated Combustion Management System with specified packaged boiler manufactures, Copy and Paste both

More information

TS93 EMF SERIES. INSPK NO Rev.03/10

TS93 EMF SERIES. INSPK NO Rev.03/10 TS93 EMF SERIES 1 Each hold open (HO) unit contains a door closer and track assembly with hold open solenoid. The unit can be connected directly to a fire control panel. 1) Read the entire instruction

More information

EDS - SPARK DETECTORS - GENERAL NOTES

EDS - SPARK DETECTORS - GENERAL NOTES 1 EDS - SPARK DETECTORS - GENERAL NOTES The spark detectors are electronic devices suitable for the detection of sparks in the pipes or transport ducts of conbustible material of different nature (sawdust,

More information

Wiring Instructions. Single Doors 99 Checkmate Series Use one or Master Unit each door or one or Support unit each door

Wiring Instructions. Single Doors 99 Checkmate Series Use one or Master Unit each door or one or Support unit each door CAUTION Hinge Edge of Door Wiring Instructions Checkmate Series with Single Point Hold-Open Combination Door Closer-Holder and Releasing Device with or without Integral Smoke Detector INSTALLER: LEAVE

More information

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3 INTELLIGENT FIRE TECHNOLOGY Twinflex and Multipoint V3 User Guide (TO BE RETAINED BY USER) 26-0340 Issue 3 Rafiki Protection Limited Rafiki policy is one of continual improvement and the right to change

More information

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS CONTENTS 1. INTRODUCTION... 5 2. WARNINGS... 6 3. GENERAL DESCRIPTION... 7 4. INSTALLATION... 8 5. LUMINOUS INDICATORS AND COMMANDS... 9 6. DIP-SWITCH

More information

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A SPECIFICATIONS (Revised 1/12/2006) ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A The system shall operate on the principle of light absorption. It shall consist

More information

FAAST. Fire Alarm Aspirating Sensing Technology

FAAST. Fire Alarm Aspirating Sensing Technology FAAST Fire Alarm Aspirating Sensing Technology The FAAST range FAAST 8100e FAAST LT PipeIQ Next Generation Aspiration Detection Detection for Challenging Environments 3 in 1 Design, Configuration and Monitoring

More information

DYCU-3 AEROSOL FIRE EXTINGUISHER CONTROL UNIT OPERATION MANUAL

DYCU-3 AEROSOL FIRE EXTINGUISHER CONTROL UNIT OPERATION MANUAL DYCU-3 AEROSOL FIRE EXTINGUISHER CONTROL UNIT OPERATION MANUAL DOC: GLT.MAN-136 1 INDEX INTRODUCTION 3 CONNECTIONS 4 OPERATION 5 LINKING 6 TECHNICAL INFO 7 DOC: GLT.MAN-136 2 INTRODUCTION The Dynameco

More information

Air Specialties Express, 448 S. Main St., P. O. Box , Verona, WI Phone: (877) Fax: (608)

Air Specialties Express, 448 S. Main St., P. O. Box , Verona, WI Phone: (877) Fax: (608) FORM ASX-40021 INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS SM-501 Series Smoke Detectors, Model EXSAC and EXSAD (Ionization), EXSAJ and EXSAK (Photoelectric) Air Specialties Express, 448 S. Main

More information

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R Region Project Page 1 PART 1 - GENERAL 1.1 REFERENCES.1 CAN/ULC-S524-2006, Standard for the Installation of Fire Alarm Systems..2 CAN/ULC-S525-2007, Audible Signal Device for Fire Alarm Systems..3 CAN/ULC-S526-2007,

More information

CU 300 GRUNDFOS INSTRUCTIONS. Installation and operating instructions

CU 300 GRUNDFOS INSTRUCTIONS. Installation and operating instructions GRUNDFOS STRUCTIONS CU 300 Installation and operating instructions No contact Overvoltage Undervoltage Dry running Speed reduction Overtemperature Overload Sensor alarm Declaration of Conformity We Grundfos

More information

OH110, OP110, HI110. Automatic Fire Detectors. Automatic Fire Detector For collective and conventional detector lines

OH110, OP110, HI110. Automatic Fire Detectors. Automatic Fire Detector For collective and conventional detector lines Automatic Fire Detector For collective and conventional detector lines Signal processing with detector algorithms Selectable parameter sets 3 colour LED indication Drift compensation Internal fault monitoring

More information

Fire Damper Interface (230V)

Fire Damper Interface (230V) Always READ this document BEFORE INSTALLATION. Please Retain for future reference. This product forms part of a life safety system. Failure to correctly store, handle, install and maintain the product

More information

Use this product according to this instruction manual. Please keep this instruction manual for future reference.

Use this product according to this instruction manual. Please keep this instruction manual for future reference. Branchport Ave. Long Branch, N.J. () Thank you for using our products. www.coopernotification.com STALLATION STRUCTIONS SPSVC SAFEPATH SUPERVISED VOLUME CONTROL Use this product according to this instruction

More information

SERIES 65 ENGINEERING PRODUCT GUIDE

SERIES 65 ENGINEERING PRODUCT GUIDE SERIES 65 ENGINEERING PRODUCT GUIDE Wide voltage conventional detectors Series 65 incorporates well-proven sensing technologies, including an IC based on that used in XP95 analogue addressable detectors.

More information

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

OilSET Installation and Operating Instructions. Oil Separator Alarm Device Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel: +358 29 006 260 Fax: +358 29 006 1260 18.11.2010 Internet: www.labkotec.fi 1/10 OilSET-1000 Oil Separator Alarm Device Copyright 2010 Labkotec

More information

2409/2900. Fire Guard

2409/2900. Fire Guard 2409/2900 Fire Guard Table of Contents Features and Additional Fire Opening Devices... 1 2409 Single-Point Hold Open Applications and Mounting Details... 2 2409 Track Assemblies, Arms and Components...

More information

Dimensions. Model Number. Electrical connection. Features. Product information. Indicators/operating means RMS-G-RC. Radar sensor

Dimensions. Model Number. Electrical connection. Features. Product information. Indicators/operating means RMS-G-RC. Radar sensor Dimensions ø.7 9.5 6.5 8.5 ø.7 65 57 Window for LED display Model Number Radar sensor Features Industrial gate opener with the ability to differentiate between people and vehicles Extra-wide detection

More information

Smoke Detector and Siren. Manual

Smoke Detector and Siren. Manual Smoke Detector and Siren Manual 004001 Smoke Detector and Siren Manual Quick Start... 2 Product Description... 2 Installation Guidelines... 3 Behavior within the Z-Wave Network... 3 Operating the Device...

More information

intelligent solutions

intelligent solutions Alco is one of the leading intelligent solution providers of Fire Detection System. Security System and Public Addressing System in the United States of America. Based in California since 1992, we have

More information

HART XL High Sensitivity Smoke Detection

HART XL High Sensitivity Smoke Detection High Sensitivity Smoke Detection The Hart XL High Sensitivity Smoke Detection system (HSSD) is an aspirating fire detection system designed to give very early indication of an incipient fire condition.

More information

DS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector

DS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector DS970-BEL EN Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector DS970-BEL Installation Instructions.0 Installation Considerations.0 Installation Considerations Not suitable

More information

PANELS, KEYPADS & MODULES. Take Fire Protection to the Next Level Fire Products from DSC

PANELS, KEYPADS & MODULES. Take Fire Protection to the Next Level Fire Products from DSC Take Fire Protection to the Next Level Fire Products from DSC AFD2000 Addressable Fire Control Panel Series Provides Maximum Flexibility The new AFD2000 is a completely programmable series of addressable,

More information

DUAL MONITORED INPUT/OUTPUT UNIT BN-305

DUAL MONITORED INPUT/OUTPUT UNIT BN-305 DUAL MONITORED INPUT/OUTPUT UNIT BN-30 Interactive fire detection systems Product Datasheet Features Interactive For interfacing and controlling external units to Autronica s interactive fire detection

More information

Conventional Fire Alarm System Product Range Guide

Conventional Fire Alarm System Product Range Guide EXPERT IN SAFETY AND SECURITY TECHLOGY CONTENTS Conventional Fire Alarm System CK1004 Conventional Fire Alarm Control Panel CK1008 Conventional Fire Alarm Control Panel CK10016 Conventional Fire Alarm

More information

CONTROL DEVICE SLIDETRONIC HD

CONTROL DEVICE SLIDETRONIC HD CONTROL DEVICE SLIDETRONIC HD to control gravity self-closing fire gates Producer: Somati system s.r.o. Jihlavská 510/2c 664 41 Troubsko, okr.brno - venkov Tel.: 547 427 011 Fax: 547 427 013 E-mail: export@somati-system.cz

More information

IR FLAME DETECTOR RIV-601/F

IR FLAME DETECTOR RIV-601/F IR FLAME DETECTOR EN 54-10 class 2 VdS approval G 205044 application manual CONTROL LOGIC rev. 4 DEC07 MAFE DEC07 IR FLAME DETECTORS SUMMARY Page general notions...3 description...4. Electrical and general

More information

"Pegaso" wireless alarm system D.I.Y. wireless kit

Pegaso wireless alarm system D.I.Y. wireless kit "Pegaso" wireless alarm system D.I.Y. wireless kit Summary Page 1.0. Description... 2 2.0. Installation... 3 3.0. Connections to mains power... 3 4.0. Low battery signalling... 4 5.0. Service key... 4

More information