m o rity.c u c e s a e.d w w w security perimeter protection systems

Size: px
Start display at page:

Download "m o rity.c u c e s a e.d w w w security perimeter protection systems"

Transcription

1

2 the antintrusion perimeter protections Only a perimeter detection system can guarantee the highest since it signals an intrusion in advance. The immediate detection induces to abandon any access attempt and permits activating an efficient defence. DEA SECURITY has devoted its own research and development activity to the field of antintrusion perimeter protections, by creating a new technology object of international patents. The result of this hard work is the realization of a wide range of very efficient products: - SERIR, metal fence protection system; - TORSUS, wire-netting protection system; - SISMA CP, underground protection system; - SISMA CA, protection system for pavings; - DEA NET, communication network at high speed; - DEA MAP, integrated management system; - SERIE A-03, indoor. 2 SISMA CP SYSTEM

3 SISMA CP system SISMA CP is an innovative antintrusion perimeter system of underground type creating an invisible and not localizable detection band around the site to be protected. SISMA CP uses special geoseismic detectors, DEA SECURITY's patent, able to perceive the pressure waves generated by a person walking on a surface made of lawn, gravel, asphalt or self-lockings. Completely invisible The sensors operate at 60 cm in depth in a constant environment which makes the system free from climatic conditions and perfectly compatible with normal gardening job. Working quota at 60 cm of depth The signals generated by the sensor strings are amplified and processed by advanced electronic boards able to recognized the various types of intrusion and to discriminate possible environmental nuisances. The digital memory of the system stores all the events detected, by providing precise information on the causes which have provoked them (DEA REPORT). Digital event recording A B B A SG-01 geoseismic sensor is a DEA SECURITY's patent Double detection confirmation The accurate choice of the materials, the innovative technology of the sensor and the high detection capacity of the analysis boards guarantee efficiency and a constant functioning in time to SISMA CP system. SISMA CP SYSTEM 3

4 The components of SISMA CP system The SG-01 sensors SG-01 detectors are able to perceive the seismic waves which, generated by a person walking on the surface, propagate in the ground. The sensitive core of SG-01 detectors is represented by a piezoceramic transducer, which produces a weak electric signal when subject to stress. The piezoceramic transducer is an inexhaustible element which, being sealed and protected by a plastic housing chemical and organic substance resistant, guarantees a constant functioning in time. SG-01 geoseismic sensors are of passive type since they are not supplied and do not contain any active electronic component. The last feature offers a double advantage: SG-01 Sensor string - there is no electronic breakdown of the sensor; - there is no electromagnetic emission, so the sensor cannot be located. The efficiency of SG-01 detectors has permitted to low the SISMA CP working quota until 60 cm of depth, guaranteeing: - A steady environment. The meteorological phenomena, even very forceful ones, only affect the first centimetres of the surface and never reach 60 cm in depth. In addition, the mechanical stress to which the sensors are subject during a possible transit of vehicles is dramatically reduced. Excavation depth: 60cm - The absence of rodents. Since these animals are mainly present in the first 30 cm of the ground, the positioning of the sensors at 60 cm of depth dramatically reduces the possibility of improper alarms and damages, the last ones also avoided by the materials used for the construction of the sensor strings. - Full compatibility with normal gardening job, without any danger for the system. Even in case of sensors used under asphalt, it is possible to carry out normal reasphalting jobs. CSST6AB connection cable CSST6AB Connection cable internal poly-ethylene sheath aluminium tape shield coverage > 100% The sensors of SISMA CP system are provided in prewired strings; the wiring is carried out through a special connection cable, CSST6AB, produced on DEA SECURITY's specifications. sisma cp system Oil and hydrocarbon resistant external shieth. Special thermoplastic composition with a PVC basis TM2 quality (CEI 20-11) anti rodent galvanized iron braid coverage > 80% tinned copper braid shield coverage > 75% polyester protection tape tinned copper conductors The cable has been specially manufactured to be used in continuous contact with the ground and adds good electric qualities to excellent mechanical features. As far as the electric aspect is concerned, in order to guarantee a perfect transmission quality of the signal and a high immunity to electromagnetic disturbances, each conductor is water proof and twisted, the shield is double since it joins aluminium tape to tinned copper braid. As far as the mechanical aspect is concerned, to offer unalterability and long operation life to the cable, the following parts have been used: an anticrushing protection of the electric conductor, an intermediate sheath to protect the conductors, a zinc-plated iron armour and an external shieth oil and hydrocarbon resistant. 4 SISMA CP SYSTEM

5 SISMA System SISMA System SISMA System SISMA System SISMA System SISMA System SISMA System SISMA System The components of SISMA CP system SE SISMA CP processing electronic board The signals generated by the sensor strings are amplified and processed by SE SISMA CP processing board. This unit represents the intelligence of the system and interprets what is perceived by the sensors. The electronic board processes the signals by using innovative analysis programs which ensure an efficient recognition of the various types of intrusion and a correct discrimination of the possible environmental nuisances. The independent regulations of the sensitivity and the intervention modes allow the system to operate in different installation ambits, always with the maximum efficiency. SG-01 sensor string STC-01 digital recording module SE SISMA CP SE SISMA CP board is integrated in STC-01 module, which provides a series of advanced functionalities: - Chronological storing of all the events detected by the system; STC-01 - PC connection to view in real time the response graph of the string sensor and, therefore, to facilitate the calibration of the system; - Management of a modem for remote connections. SE SISMA MCP a new technology The continuous research has led to create a new electronic board, offering additional functionalities and new performances. SE SISMA MCP exploits a microprocessor to quicken the processing of the signals, now relied on more advanced programs, and it is able to manage up to 2 strings contemporaneously and in an independent way. SE SISMA MCP The memory to record the events has greater dimensions and a superior resolution, while all the settings are carried out from one's PC, by exploiting the intuitive graphics of the management software. SE SISMA MCP is able to directly manage a modem and to connect to DEA NET, through which it is possible to control very extended sites from a unique position (DEA MAP). SISMA CP SYSTEM 5

6 SISMA System SISMA System SISMA CP technology in depth Independent detectors SG-01 sensors are independent detectors, since each of them controls its own detection area. The use of independent detectors, compared with linear sensors, offers the following advantages: - High level of functional redundancy of the string, since the breakdown or the damage of any of the sensors do not compromise the detection capacity of the other sensors; - Quick recovery of the detection capacity of the single damaged sensor through a simple replacement of the sensor and an electric connection of the junction cable, without replacing the whole string; - Absence of background noises, typical effect present in linear sensors which are normally composed of a unique sensor element, along a very extended analysis front and for this reason subject to environmental nuisances; - Possibility of AND function on a unique string. Being independent detectors, SG-01 sensors are assembled in an alternate way on two different connection lines, so as to obtain a double consent functioning. AND detection (two lines in one) Each sensor string of SISMA CP system is composed of two types of sensors, A and B, which are connected in an alternate way. A sensors and B sensors are completely independent from one another and transmit their own signals through two different electric connections; in this way the processing board has at its disposal information coming from two distinct sources and it can therefore carry out a more accurate analysis to recognize the intrusion. Practically, according to the type and to the intensity of the seismic wave propagating in the ground, only A type sensors or B type sensors are concerned, or both of them. In addition, the intensity of the signals generated by the two types of sensors depend on the entity of the shock on the ground and on the distance between the shock place and each sensor. For example, a person's steps generate seismic waves which can be detected by both of the sensors, while a small animal's passing generates a signal only for one of the two detectors. A B AND signals signal on line B A B A signal on. line A maximum signal on line A maximum signal on line B Double detection consent Substantially, AND detection is based on a combined analysis coming from A type detectors and B type detectors and ensures an optimum level of sensitivity and a high degree of immunity towards small animals. Besides AND mode, SISMA CP system processing board also offers OR mode, which exploits an independent analysis of the signals coming from A sensors or B sensors. This type of functioning, which gives the system the maximum detection capacity, is suitable for installations in military sites, prisons and telecommunication centres. 6 SISMA CP SYSTEM

7 SISMA CP technology in depth Limited analysis front Each string of SISMA CP is composed of up to 50 detectors able to protect a perimeter section of about 45 m. This size, which is highly valid in residential, industrial and military sites, offers the possibility to: - optimize the management of different types of surfaces; - exactly locate the perimeter section subject to attack; - easily interact with a CCTV system. DEA REPORT analysis of the events recorded Zone length compatible with CCTV systems Zone Zona 2 Zone Zona 3 Zone Zona 4 Zone Zona 5 Zone Zona 11 Zona Zone 6 View of events stored on STC-01 board alarm intrusion Zone Zona 8 Zone Zona 7 The high filing capacity of SISMA CP system permits recording all the events occurred over very long times (even months), with the exactness of few milliseconds. DEA SECURITY offers its own experience to examine the data recorded by the memory of the system, easily coming back to the seismic wave present in the ground in the moment the event occurred and therefore to the causes which have provoked it. The result is an accurate technical report of analysis (DEA REPORT) which can have both the function of a system check-up and a verification in consequence of an alarm signal. Remote connection modem modem Phone line SG-01 sensor string SE SISMA MCP processing board SE SISMA CP processing board is able to manage a modem which permits executing a remote connection by exploiting a normal telephone line. Once the connection to the board has been carried out, it is possible to download the stored events and view in real time the reply graph of the string. With the new board SE SISMA MCP is also possible to intervene on all the setting parameters of the system. Real time signal view SISMA CP SYSTEM 7

8 How to realize a SISMA CP system Environmental analysis SISMA CP can be installed in lawns, in surfaces covered with gravel, asphalt, interlockings or slabs in general, and in all the sites where there is no rigid structure, like concrete, coming between the system and the surface. In case of interlockings or tiles, these must be directly laid on the ground without using a concrete base. The correct calibration of the processing board permits the system to reach the best performances according to the ground in which it operates. The direction of the strings must not be rectilinear but wavy, and traced out so as to keep an adequate distance (about 3 m) from possible disturbing elements, such as trees, posts, arbours and the like, which can swing under the action of the wind. Pressure pipe coverage An other aspect to be considered is the presence of pressure pipes which can propagate seismic waves in the ground. A string parallel to a pipe will have to keep a distance of at least 2 m, while in case of intersection, the pipe will have to be insulated to avoid vibrations. Perimeter sectioning As a consequence of a passing on the surface, the several types of surface (lawn, asphalt, gravel) cause a seismic wave having different features. When designing, it is important to divide the perimeter in order to have a dedicated string for each variation of zone (example when passing from lawn to asphalt). In addition, the subdivision of the perimeter into zones must allow a quick individuation of the alarm sector and an easy management of the detection system. Lawn Gravel Self-lockings Asphalt 8 SISMA CP SYSTEM

9 How to realize a SISMA CP system Example We hypothesize the protection of a perimeter of 180 m, divided into 3 zones, by setting the relative electronic boards into one cabinet situated near the control panel (CP). STRING 1 CSST6AB CABLE RI G ST N 3 GRAVEL PATH CONTROL PANEL CP STRING 2 FEATURES OF THE SITE AND THE DETECTION SYSTEM: Overall perimeter: 120m Types of ground: lawn 85m gravel 35m No of SG-01 detectors: 135 (sensors necessary for a laying at 0.90m pitch) No of alarm zones: 3 No of SE SISMA CP boards: 3 Material you need (for the site in the example above) Q.ty CODE DESCRIPTION 135 SG 01 Pre-wired geoseismic detectors (string 1: no 45; string 2: no 50; string 3: no 40) 1 every 90 cm 100m CSST6AB Connection cable between the sensor strings and the processing boards 3 CTR CP Box for initial string junction 3 CT2580 N Box for final string terminal 3 KIT R 250 Epoxy for connection sealing 3 SE SISMA CP Processing electronic board 3 STC-01 Digital event recorder 1 AL35 Stabilized linear power-supply (12V DC, 3.5 A) 1 AP2 Polyester waterproof cabinet, with tamper 1 SW STC-01 Management software included in STC 01 digital recorder SISMA CP SYSTEM 9

10 How to realize a SISMA CP system Wiring All the electric connections of the sensor strings must be welded and protected with bicomponent epoxy KIT R 250. Each kit can seal 2 CTR CP or 3 CT2580N boxes. Board positioning The processing board can be set in the room of the control panel, if this is situated within 150 m from the beginning of the string, or in special waterproof external cabinets (peripheral cabinets) to be positioned near the sensor strings. The last solution, suggested for great perimeters, minimizes the quantity of cable necessary for the connection between the sensor string and the processing boards. End of line junction sealing Peripheral cabinet usage Each peripheral cabinet contains: - the processing boards; - a stabilized linear power-supply; - an emergency buffer battery. The new SE SISMA MCP microprocessor boards permit carrying out the centralized management of the system through DEA communication net (DEA NET). In this case, a connection cable FTP shielded cat. 5 will have to be used for the transmission of the data from the peripheral cabinets to DEA NET controller. Cabinet containing the processing boards Peripheral cabinet suitable for external usage Excavation Sensor laying Connection and sealing of the junctions Sensor coverage with sand Excavation coverage Connection and test MAX 45m (50 SG-01) CSST6AB connection cable CT2580N string terminal Distance: 90 cm SG-01 sensor string CTRCP initial string junction SE SISMA MCP processing board 10 SISMA CP SYSTEM

11 Technical specifications The sensor The connection cable sism a cp system The processing boards SG 01- Double line pre-wired geoseismic detector Approvals: EMC 89/336 -non power-supplied sensor Dimensions: 90 x 185 (Ø x h ) mm Operating temperature: C Relative humidity: 100 % Available in standard strings of 10, 20,30,40 or 50 detectors. CSST6AB - Cable to connect SISMA CP strings to their processing boards Approvals: CEI 20-11, CEI 20-14, CEI 20-35, (IEC 332-1) 73/23/CEE, 93/68/CEE Conductors: 6 tinned copper conductors, twisted pair. Diameter: 10,5 mm Operating temperature: C External insulation: KV Shield: Braid (coverage > 75%) + aluminium tape (coverage > 100%) Antirodent, galvanized iron braid shieth. Oil and hydrocarbon resistant. Colour: GREY NEW! The event recorder SE SISMA CP - Processing board for 1 SG 01 sensor string 1 zone Approvals: EMC 89/336 CEE EN : (CE97) CEI 79/2 2nd ed. 2nd level Dimensions: 180 x 130 mm (b x h) Power supply: 12 DC ( V) Current: 140 ma (stand by), 180 ma (MAX) Operating temperature: C Relative humidity: < 95% non condensing Inputs: 1 SG-01 sensor string Opto-insulated for supplementary controls 1A relay NC outputs: Tampering - pre-alarm - alarm OC Outputs: For supplementary signaling Analysis capacity: 1 SG 01 string with max 50 sensors Analogue calibrations, 4 intervention programs, got ready for the event recording module (STC-01) SE SISMA MCP - Microprocessor electronic board for 2 SG 01 sensor strings 2 Zones Approvals: EMC 89/336 CEE EN A1: CE 2003 EMC EN : 2001 CEI 79/2 2nd ed. 2nd level Dimensions: 180 x 130 mm (b x h) Power supply: 12V DC ( V) Current: 140 ma (stand by), 180 ma (max) Operating temperature: C Relative humidity: inputs: < 95% non condensing 2 SG-01 sensor strings Opto-insulated for supplementary controls 1A relay NC outputs: Alarm string 1 - alarm string 2 Tamper string 1 - tamper string 2 OC Outputs (negative): Pre-alarm string 1 - Pre-alarm string 2 with common output +12V: Analysis capacity: 2 SG 01 strings with max 50 sensors each Calibration, settings, event management via PC and SW SISMA MCP, through serial port. Direct management of a modem for remote connections. STC-01 - Digital event recorder and advanced functionalities for SE SISMA CP board Dimensions: 100 x 70 mm (b x h) Power supply: 5 V cc (via strip on the SE SISMA CP board) Current: 40 ma (max) Operating temperature: C Relative Humidity: < 95% non condensing Functions: Chronological memory of the events detected by the sensor string. PC connection and real time view of the string signals. Modem management for remote connection. SISMA CP SYSTEM 11

12 Technical specifications What one needs for the junctions CTR CP- Initial string junction box SISMA CP To be sealed with bicomponent epoxy (KIT R 250) Dimensions: 70 x 70 x 40 mm (b x d x h) Colors: Black CT2580 N - Box for string terminal -SISMA CP To be sealed with bicomponent epoxy (KIT R 250) Dimensions: 25 x 80 mm (Øx h) Colors: Black KIT R 250 -Bicomponent epoxy kit to seal connections.250g kit for: 3 sealings inside CT2580, or 2 sealings inside CTR CP The softwares (license supplied with the processing boards) SW STC-01 - Management software for STC-01 module Connection: PC Windows via serial port (standard cable). System requirements: Pentium PC Mhz or superior MS-Windows 95 or superior. 10 Mb free space on hard disk. Functions: Real time view of the graph of the signal detected by the sensor string. It permits storing, managing and transmitting event files. p e r im e SOFTWARE t e p r r o te io t c n system SW SISMA MCP - Software to control and set SE SISMA MCP board Connection: PC Windows via serial port (standard cable). System requirements: Pentium 2 class PC with- 266 Mhz CUP or faster. MS-Windows 98 or superior. 10 Mb free space on hard disk. Functions: Real time view of the graph of the signal detected by the sensor string. It permits setting the sensitivity levels (digital trimmers) and the levels. It permits storing, managing and transmitting the event files. The cabinets AP- Waterproof polyester peripheral cabinet, U.V. resistant. Protection degree: IP65 Provided with: base plate, lock, clamps, antitamper device Versions e dimensions: AP1 - dimensions 405 x 500 x 200 mm (b x h x d) AP2 - dimensions 405 x 650 x 200 mm (b x h x d) AP3 - dimensions 515 x 650 x 250 mm (b x h x d) Stabilized linear power-supplies Common features: Dimensions: 95 x 105 x 185 mm (b x h x d) Input voltage: 230V - 50Hz Operating temperature: C Relative humidity: < 95% not condensing Versions: AL15 output voltage: AL25 output voltage: AL35 output voltage: 13.8 V DC - 1.5A current: 160mA (MAX) 13.8 V DC - 2.5A current: 280mA (MAX) 13.8 V DC - 3.5A current: 530mA (MAX) 12 SISMA CP SYSTEM

13 SISMA CP SISMA CP SYSTEM 13

14 14 SISMA CP SYSTEM

15 Headquarters Dea Security snc Via Magenta, Massa (MS) tel fax wwww.dea.com dea@dea.com Branch in Veneto (North of Italy) Dea Security snc Viale Trieste, Alte di Montecchio Maggiore (VI) tel/fax deaveneto@dea.com SISMA CP SYSTEM INFORMATION NOTES November 2004 edition - version Following a policy of continuous developement, DEA SECURITY reserves the right to vary at any moment and without notice, the information and the technical features herein. SISMA CP SYSTEM 15

16

SERIR. perimeter protection systems. Informative Note SERIR System - edition March v

SERIR. perimeter protection systems. Informative Note SERIR System - edition March v perimeter protection systems perimeter intrusion detection system for metal fences Informative Note System - edition March 2012 - v. 1.0.1 Perimeter intrusion detection systems Perimeter intrusion detection

More information

TORSUS 50. perimeter intrusion detection system for metal fences. Informative Brochure

TORSUS 50. perimeter intrusion detection system for metal fences. Informative Brochure TORSUS 50 perimeter intrusion detection system for metal fences Informative Brochure 2 Contents Perimeter intrusion detection systems... 5 1. TORSUS 50 system... 7 1.1 The components of the system... 8

More information

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR 2 MB 103 TRANSFORMER TEMPERATURE CONTROL UNIT WITH CONTROL SIGNAL Recent approval of new

More information

Committed to security

Committed to security PERIMETER SECURITY Committed to security PERIMETER INDEX This document is the first Catalogue of Perimeter Security Technologies. We introduce the technologies used by our company for perimeter security,

More information

SERIE A03 SERIE SPC/SPR

SERIE A03 SERIE SPC/SPR Product Catalogue SERIE A03 SERIE SPC/SPR Seismic detectors for indoor perimeter protections 2 TITOLO PREMISE DEA Security specializes in the production of sensors and electronic processing boards for

More information

PMD2 Plus series. Enhanced Walk-Through Metal Detectors. NEW. Threat Detection through Electromagnetics GENERATION

PMD2 Plus series. Enhanced Walk-Through Metal Detectors.  NEW. Threat Detection through Electromagnetics GENERATION NEW GENERATION Superior Detection and Throughput Certified to the strictest Security Standards Column and Panel versions Unmatched Reliability & No Calibration and Maintenance required Rapid Installation

More information

ClampOn DSP Corrosion- Erosion Monitor

ClampOn DSP Corrosion- Erosion Monitor ULTRASONIC INTELLIGENT SENSORS ClampOn DSP Corrosion- Erosion Monitor DIGITAL SIGNAL PROCESSING ULTRASONIC INTELLIGENT SENSORS ClampOn DSP Corrosion-Erosion Monitor The patented ClampOn DSP Corrosion-Erosion

More information

WG Buried Fibre Cable Long Perimeter Detection System

WG Buried Fibre Cable Long Perimeter Detection System WI CODE : 11954 Telephone : +44 (01295 756300 Fax : +44 (0)1295 756302 E-Mail : info@wi-ltd.com Website : www.wi-ltd.com WG Buried Fibre Cable Long Perimeter Detection System The WG Buried Cable Long Perimeter

More information

INTREPID Buried Cable Perimeter Intrusion Detection System

INTREPID Buried Cable Perimeter Intrusion Detection System INTREPID Buried Cable Perimeter Intrusion Detection System TM M icrotrack, the latest addition to Southwest Microwave s INTREPID TM family of intrusion detection products, is a new buried cable intrusion

More information

INTREPID Perimeter Intrusion Detection System

INTREPID Perimeter Intrusion Detection System TM INTREPID Perimeter Intrusion Detection System Next Generation Perimeter Protection icropoint Cable combines patented Southwest Microwave technology with microprocessor power and laptop computer convenience.

More information

Fiber Optic Cable Fence Disturbance Sensor

Fiber Optic Cable Fence Disturbance Sensor Architectural & Engineering Specification for Fiber Optic Cable Fence Disturbance Sensor Purpose of document This document is intended to provide performance specifications and operational requirements

More information

VIBRA-series: VIBRA, VIBRA +

VIBRA-series: VIBRA, VIBRA + DATASHEET VIBRA-series (VIB.00100/..120/..130) VIBRA-series: VIBRA, VIBRA + Profound VIBRA-series Vibrations from pile driving, construction, road or rail traffic, demolition work and blasting can create

More information

INTREPID Buried Cable Perimeter Intrusion Detection System

INTREPID Buried Cable Perimeter Intrusion Detection System TM INTREPID Buried Cable Perimeter Intrusion Detection System icrotrack, the latest addition to Southwest Microwave s INTREPID family of intrusion detection products, is a new buried cable intrusion detection

More information

FT702LT Turbine control wind sensor gives durability a new meaning FT702LT. series

FT702LT Turbine control wind sensor gives durability a new meaning FT702LT. series FT702LT Turbine control wind sensor......gives durability a new meaning FT702LT series Proven High Availability The FT702LT ultrasonic anemometer is the result of FT Technologies 10 years of experience

More information

Catalogue Telecommunication Cables INTRODUCCIÓN

Catalogue Telecommunication Cables INTRODUCCIÓN Catalogue Telecommunication Cables INTRODUCCIÓN Conductores Tecnológicos S.A. www.contecsa.es Index of Cables Page Introduction 3 EAP / EAP-R 4 EAPSP / EAPSP-R 5 ISP / ICP 6 Conductores Tecnológicos S.A.

More information

WG Buried Cable Perimeter Detection System

WG Buried Cable Perimeter Detection System Telephone : +44 (01295 756300 Fax : +44 (0)1295 756302 E-Mail : info@wi-ltd.com Website : www.wi-ltd.com WG Buried Cable Perimeter Detection System The WG Cable Detection Sensor is a covert outdoor perimeter

More information

Catalogue. Instrumentation & Control Cables

Catalogue. Instrumentation & Control Cables Catalogue Instrumentation & Control Cables Conductores Tecnológicos S.A. www.contecsa.es Index of Cables Page Introduction 3 Instrumentation VOV 4 VHOV 5 VOVMV 6 VHOVMV 7 Control RV 8 RZ1C3Z1 9 Conductores

More information

SMD601 Plus. The most Sensitive Multi-Zone Metal Detector for Law Enforcement and Correctional Facilities. Threat Detection through Electromagnetics

SMD601 Plus. The most Sensitive Multi-Zone Metal Detector for Law Enforcement and Correctional Facilities. Threat Detection through Electromagnetics The most Sensitive Multi-Zone Metal Detector for Law Enforcement and Correctional Facilities new reference standard in sensitivity Most Sensitive WTMD, fully compliant with the NIJ-0601.02 and NIJ-0601.03

More information

PMD2 Plus. Enhanced Walk-Through Multi-Zone Metal Detector. new. Threat Detection through Electromagnetics. generation

PMD2 Plus. Enhanced Walk-Through Multi-Zone Metal Detector. new. Threat Detection through Electromagnetics. generation PMD2 Plus Enhanced Walk-Through Multi-Zone Metal Detector new generation Superior Detection and Throughput Very High Discrimination Compliant with the strictest Security Standards Column and Panel versions

More information

Telecommunication Cables

Telecommunication Cables Telecommunication Cables Telecommunication Cables Introduction 3 EAP / EAP-R 4 EAPSP / EAPSP-R 5 ISP / ICP 6 Page ELECWIRES 2 www.elecwires.es INTRODUCCIÓN Telecommunication Cables Telephone cables suitable

More information

Installation Guide for inbiox60 Series Access Control Panel

Installation Guide for inbiox60 Series Access Control Panel Installation Guide for inbiox60 Series Access Control Panel Version: 1.0 Date: April, 2011 About This Manual This manual is a guide to installation and connection of the inbiox60 series access control

More information

HI-PE HIGH PERFORMANCE WALK-THROUGH MULTI-ZONE METAL DETECTOR. Threat Detection through Electromagnetics

HI-PE HIGH PERFORMANCE WALK-THROUGH MULTI-ZONE METAL DETECTOR. Threat Detection through Electromagnetics HIGH PERFORMANCE WALK-THROUGH MULTI-ZONE METAL DETECTOR Accurate Detection of magnetic, non-magnetic and mixed-alloy metal weapons High Discrimination and Throughput Exceptional Immunity to environmental

More information

Product Specification

Product Specification Southwest Microwave, Inc. 9055 S. McKemy Street Tempe, Arizona 85284 USA (480) 783-0201 Fax (480) 783-0401 Product Specification INTREPID MicroTrack Buried Cable Perimeter Intrusion Detection System System

More information

SCR100 User Manual. Version:1.1 Date:Dec 2009

SCR100 User Manual. Version:1.1 Date:Dec 2009 SCR100 User Manual Version:1.1 Date:Dec 2009 Introduction: This document mainly introduces the installations and connections of SCR100 products, and the brief operations about attendance software. Important

More information

7638 Standish Place Derwood, MD Tel: (301) Fax: (301) Page 1 of 12. Website:

7638 Standish Place Derwood, MD Tel: (301) Fax: (301) Page 1 of 12. Website: 7638 Standish Place Derwood, MD 20855 Tel: (301) 760-4016 Fax: (301) 762-2253 Page 1 of 12 Website: www.rbtec.com E-Mail: info@rbtec.com Purpose The purpose of this document is to provide performance specifications

More information

Architectural and Engineering Specification for a Fence-Mounted Perimeter Intrusion Detection System. FlexZone

Architectural and Engineering Specification for a Fence-Mounted Perimeter Intrusion Detection System. FlexZone Architectural and Engineering Specification for a Fence-Mounted Perimeter Intrusion Detection System FlexZone April 15, 2014 Page 1 of 14 G6DA0115-001 This document is intended to provide performance specifications

More information

Intrusion Outdoor Protection Perimeter

Intrusion Outdoor Protection Perimeter Intrusion Outdoor Protection Perimeter Borders Commercial industrial Military base Correctional institution VIP Estates/Residences Communication Airports Warehouses Perimeter Sensors: the ideal solution

More information

PREVENTIVE PROTECTION PROTECCIÓN PREVENTIVA

PREVENTIVE PROTECTION PROTECCIÓN PREVENTIVA PREVENTIVE PROTECTION PROTECCIÓN PREVENTIVA R PREVENTIVE PROTECTION ATSTORM v2 is a storm detector that measures the environmental electric field. It is fully automatic, without mobile parts, robust and

More information

Movement Detector GJD 300

Movement Detector GJD 300 Movement Detector GJD 300 Installation & Set Up Guide Introduction A CCTV event trigger utilising two independent passive infrared detectors combined in a T05 package. Both sensors have to trigger before

More information

Perimeter Intrusion Detection System

Perimeter Intrusion Detection System System System Features & Advantages 1. Hardware Zone In hardware zone application, a perimeter is segregated into different detection zones deployed with several sets of sensing fibers. On the other hand,

More information

Rules for Intruder Alarm Systems

Rules for Intruder Alarm Systems Rules for Intruder Alarm Systems Opening detectors (Magnetic contacts) Part 1: Requirements VdS 2120en 03/96 (03) Subject 44 1 General; 2 Terms and definitions; 3 Classification 1 General 1.1 Scope These

More information

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit D-TECT 2 GJD300 Quad PIR Movement Detector Package Contents Package Contains: 1 x D-Tect 2 1 x Drilling template for fixing holes 3 x 31.75mm wall plugs 3 x 31.75mm screws 2 x Spare Sliding Curtains 2

More information

G-MAX IVS R123 Vibration Sensors Perimeter Intrusion Detection System

G-MAX IVS R123 Vibration Sensors Perimeter Intrusion Detection System PS-4001-48461-A G-MAX IVS R123 Sensors Perimeter Intrusion Detection System Product Specifications G-Max Security Tech Ltd a l d o r e c o t e c L td. I n t e g r a t e d S e c u r i t y s y s t e m s

More information

SL-3 Vibration Sensor line A&E Specifications Page 1 of 12 SL-3 AE v doc

SL-3 Vibration Sensor line A&E Specifications Page 1 of 12 SL-3 AE v doc SL-3 Vibration Sensor line A&E Specifications Page 1 of 12 SL-3 AE v2.0 05-14.doc Purpose The purpose of this document is to provide performance specifications and operational requirements for the RBtec

More information

Presented By. BEI Security

Presented By. BEI Security Presented By BEI Security Fiber Optic Perimeter Intrusion Detection Systems BEI Security 30 years of experience in security and surveillance Fiber optic perimeter detection Video motion detection Covert

More information

Perimeter security using Fibre optics

Perimeter security using Fibre optics Perimeter security using Fibre optics Fibre optic sensors detect intrusion at the fence line. This technology provides a new dimension in detecting and locating fence line and perimeter intrusions. A laser

More information

Very High Sensitivity Multi-Zone Metal Detector for Law Enforcement and Correctional Facilities.

Very High Sensitivity Multi-Zone Metal Detector for Law Enforcement and Correctional Facilities. SMD601 for Law Enforcement and Correctional Facilities NEW GENERATION Most Sensitive WTMD, fully compliant with the NIJ-0601.02 Standard Very Accurate Pinpointing of individual and multiple metal targets

More information

Section PERIMETER SECURITY SYSTEMS

Section PERIMETER SECURITY SYSTEMS Section 28 16 43 PERIMETER SECURITY SYSTEMS PART 1 GENERAL 1.1 SUMMARY A. Provide and install a perimeter security system as herein specified for the purpose of detecting entry into a designated security

More information

Catalogue Power Cables

Catalogue Power Cables Catalogue Power Cables Conductores Tecnológicos S.A. www.contecsa.es Index of Cables Page Introduction 13 RV 14 RVMV 15 RVSV 16 RVFV 17 Conductores Tecnológicos S.A. 2 www.contecsa.es INTRODUCTION Power

More information

InBio X60 Series Access Control Panel User Manual

InBio X60 Series Access Control Panel User Manual InBio X60 Series Access Control Panel User Manual Version: 1.4 Date: Nov., 2015 About This Manual This manual introduces the installation connection and user manual of the InBio X60 Series Access Control

More information

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor DSF xx15.xx xhv Ex-Atex Product ID Type # Product # Drawing # DSF 1215.01 SHV Ex-atex (5m) 304Z-05197 113216 DSF 1415.01 AHV Ex-atex S148 304Z-05256 113351 DSF 1615.01 SHV Ex-atex (5m) 304Z-05196 113214

More information

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design. ADDISON Flame Retardant RG59 B/U Coaxial cables Plain copper wire braid PE Solid Bare Copper PVC Outer Sheath APPLICATION The cables are designed for CCTV, security, smoke detection and evacuation monitoring

More information

Product Specifications

Product Specifications Southwest Microwave, Inc. 9055 S. McKemy Street Tempe, Arizona 85284 USA (480) 783-0201 Fax (480) 783-0401 Product Specifications Procurement Specifications INTREPID MicroPoint Cable System Perimeter Detection

More information

INTERNAL DETECTORS. Wired and two-way wireless grade 2 and 3 internal detectors

INTERNAL DETECTORS. Wired and two-way wireless grade 2 and 3 internal detectors INTERNAL DETECTORS Wired and two-way wireless grade 2 and 3 internal detectors An extensive range of internal detectors utilising the latest Pyronix patented technologies for residential, commercial and

More information

English. Italiano. Português. Françias. Español

English. Italiano. Português. Françias. Español DT AM Grade 3 Español Françias Português Italiano English High Ceiling Mount Detector Installation Guide English DT AM Grade 3 High Ceiling Mount Detector Installation Guide General Description The Industrial

More information

Audible warning devices for external alarm

Audible warning devices for external alarm VdS SCHADENVERHÜTUNG VdS Publisher: Gesamtverband der Deutschen Versicherungswirtschaft e.v. (GDV) Büro Schadenverhütung Publishing house: VdS Schadenverhütung Rules for Intruder Alarm Systems Audible

More information

Shipboard & Offshore Cables

Shipboard & Offshore Cables Shipboard & Offshore Cables Shipboard & Offshore Cables Páge Introduction 3 Power Cables XL / XL-FR 5 XC4L / XC4L-FR 6 XLC4L / XLC4L-FR 7 Instrumentation cables XHL / XHL-FR 8 XOL / XOL-FR 9 XHC4L / XHC4L-FR

More information

Product Specifications

Product Specifications Southwest Microwave, Inc. 9055 S. McKemy Street Tempe, Arizona 85284 USA +1(480) 783-0201 Fax +1(480) 783-0401 Product Specifications 1.0 INTREPID Series II - MicroNet II Perimeter Intrusion Detection

More information

BC3250. Blowdown Controller

BC3250. Blowdown Controller Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

PROVEN PERIMETER PROTECTION NEW SINGLE-PLATFORM SIMPLICITY.

PROVEN PERIMETER PROTECTION NEW SINGLE-PLATFORM SIMPLICITY. SMARTER PERIMETER DETECTION SYSTEMS MicroPoint II Fence Detection System MicroTrack II Buried Cable Detection System MicroWave 330 Digital Microwave Link PROVEN PERIMETER PROTECTION NEW SINGLE-PLATFORM

More information

Protecting Station Platform & Rail Perimeters. TransitVUE IDS The Latest in Fiber Optic Station Platform & Rail Perimeter Security Sensor Systems

Protecting Station Platform & Rail Perimeters. TransitVUE IDS The Latest in Fiber Optic Station Platform & Rail Perimeter Security Sensor Systems TransitVUE IDS The Latest in Fiber Optic Station Platform & Rail Perimeter Security Sensor Systems Transit Applications Station Platforms and Security Gates Train Track & Highway-Rail Intersections Fenced

More information

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009 STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009 Introduction Honeywell s STT 3000 family of microprocessor based transmitters covers the full

More information

ALARMLINE ANALOGUE Linear Heat Detection System

ALARMLINE ANALOGUE Linear Heat Detection System ALARMLINE ANALOGUE Linear Heat Detection System Alarmline Analogue cable senses temperature variations by continuously monitoring the resistance of specially doped Negative Temperature Coefficient (N.T.C.)

More information

D-Tect 2 GJD300 Quad PIR Movement Detector

D-Tect 2 GJD300 Quad PIR Movement Detector D-Tect GJD0 Quad PIR Movement Detector Package Contents 3. Package Contains: x D-Tect x Drilling template for fixing holes x Allen Key 3 x 3.75mm wall plugs 3 x 3.75mm screws x Spare Sliding Curtains x

More information

Professional perimeter intrusion detection system

Professional perimeter intrusion detection system PROTECTS YOUR PERIMETER MORE EFFECTIVELY + Detects an intruder directly on the boundary of the protected area + Suitable for various types of fences + Gains sufficient time for the security operator for

More information

Self-learning Room Temperature Controller

Self-learning Room Temperature Controller 2 257 Self-learning Room emperature Controller 5 operating modes and menu selection via roller selector REV16 Mains-independent room temperature controller Straightforward, self-explanatory menu selection

More information

FLV 40 UV Flame Detector

FLV 40 UV Flame Detector FLV 40 UV Flame Detector TECHNICAL INSTRUCTIONS FOR INSTALLATION, SETUP ANDMAINTENANCE EDS srl - V. Cà Nova Zampieri 6-37057 S.G.Lupatoto - Verona - Italy - tel +39045547529 - fax. +390458750065 - Mail:

More information

Analog Annunciator Unit SACO 16 A3. Product Guide

Analog Annunciator Unit SACO 16 A3. Product Guide Issued: Aprill 1999 Status: Updated Version: C/20.03.2006 Data subject to change without notice Features Powerful, flexible and field-customizable 16-channel analog input signal annunciator unit A full

More information

protection Constant wattage heating cables Self-regulating heating cables Temperature controllers

protection Constant wattage heating cables Self-regulating heating cables Temperature controllers snow & ice protection Constant wattage heating cables Self-regulating heating cables Temperature controllers Protection of roofs, gutters and downpipes Snow and ice protection systems protect against:

More information

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

DEB71. Earth Leakage Monitoring Relay. Benefits. Description Earth Leakage Monitoring Relay Benefits Adjustable trip level. Adjustable leakage threshold from 30mA to 5A or from 300mA to 30A. 2 outputs. Two relay outputs provide, besides the alarm signal an additional

More information

InvisiFence User Manual

InvisiFence User Manual InvisiFence User Manual Version 1.2 Date May 2016 Table of Contents 1. Introduction... 3 2. General... 3 3. System Components... 4 4. Hierarchy of system components... 6 5. Processing unit Connections...

More information

Attention Items: I. Brief Introduction

Attention Items: I. Brief Introduction 1 Content Attention Items:... 3 I. Brief Introduction... 3 II. Model Difference... 3 III. Technical Specifications... 4 IV. Detector Structure... 5 V. Network Structure... 5 VI. The Principle and Application

More information

optris TM Temperature Monitor for Infrared Sensors Operators manual

optris TM Temperature Monitor for Infrared Sensors Operators manual optris TM Temperature Monitor for Infrared Sensors Operators manual CE-Conformity The product complies with the following standards: EMC: EN 61326-1:2006 (Basic requirements) EN 61326-2-3:2006 Safety:

More information

FlexPS. Architectural & Engineering. Specification for FlexPS. Architectural/Engineering Specification for a

FlexPS. Architectural & Engineering. Specification for FlexPS. Architectural/Engineering Specification for a Architectural/Engineering Specification for a Fence-Mounted Perimeter Intrusion Detection System FlexPS Disclaimer Senstar, and the Senstar logo are registered trademarks, and FlexPS, Silver Network and

More information

ClampOn DSP Pig Detector

ClampOn DSP Pig Detector ULTRASONIC INTELLIGENT SENSORS ClampOn DSP Pig Detector DIGITAL SIGNAL PROCESSING ULTRASONIC INTELLIGENT SENSORS ClampOn DSP Pig Detector A Pig Detector is a tool that is always used in pigging operations.

More information

/8 DIN Level Indicator

/8 DIN Level Indicator Data Sheet SS/_6 High visibility 5-digit LED display clear and accurate indication Analog and relay outputs as standard high, low, latch and rate alarms, plus isolated retransmission Maths functions included

More information

INTREPID SINGLE-PLATFORM PERIMETER INTRUSION DETECTION AND MONITORING SYSTEM

INTREPID SINGLE-PLATFORM PERIMETER INTRUSION DETECTION AND MONITORING SYSTEM Southwest Microwave, Inc. 9055 S. McKemy Street Tempe, Arizona 85284 USA +1(480) 783-0201 Fax +1(480) 783-0401 Product Specifications INTREPID SINGLE-PLATFORM PERIMETER INTRUSION DETECTION AND MONITORING

More information

SensoGuard. Seismic Security Solutions

SensoGuard. Seismic Security Solutions SensoGuard Seismic Security Solutions About Founded on January 2012 Founders have extensive experience in seismic security systems Develop security solutions based on seismic technology Field proven systems

More information

Customers. The core of our innovation. Feeding&Conveying. Drying Dosing Temperature Control Refrigeration Granulation

Customers. The core of our innovation. Feeding&Conveying. Drying Dosing Temperature Control Refrigeration Granulation EN Customers. The core of our innovation Feeding&Conveying Drying Dosing Temperature Control Refrigeration Granulation Piovan Drying Technologies: Desiccant Bed Dryers Dried air is generated by means of

More information

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores)

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores) Caledonian Flame Retardant Power & Control Cables www.caledonian-s.co.uk www.addison-s.com 600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores) FTX400 1RZ1MZ1-R (CU/XLPE/LSZH/DSTA/LSZH

More information

EnvironmentalMonitoring

EnvironmentalMonitoring Datasheet Numerous sensors, detectors and expansion modules are available for the requirements in ambient and device monitoring. All units are self-developed by Neol so the highest technical requirements

More information

Architectural and Engineering Specification for a Fence-Mounted Perimeter Intrusion Detection System. FlexZone

Architectural and Engineering Specification for a Fence-Mounted Perimeter Intrusion Detection System. FlexZone Architectural and Engineering Specification for a Fence-Mounted Perimeter Intrusion Detection System FlexZone October 27, 2015 Page 1 of 15 AE-G6-IN-R4-E-10/15 This document is intended to provide performance

More information

M O T I O N DETECTORS. The Paradox series of motion detectors. combines advanced features and patented. technologies to provide a high level of

M O T I O N DETECTORS. The Paradox series of motion detectors. combines advanced features and patented. technologies to provide a high level of M O T I O N DETECTORS The Paradox series of motion detectors combines advanced features and patented technologies to provide a high level of detection and false alarm prevention. Whatever the application,

More information

PRODUCT CATALOGUE Norröna

PRODUCT CATALOGUE  Norröna PRODUCT CATALOGUE Norröna WWW.SCANKAB.COM Table of contents MARINE AND OFFSHORE CABLES 1 TOXFREE XZ1-K (AS) - 0.6/1 kv 1 TOXFREE MARINE XO2TCuZ1-K (AS) - 150/250 V 5 4x2xAWG 24/1 CAT6 S/FTP LSZH-SHF1 -

More information

NGC-20-C-E and NGC-20-CL-E

NGC-20-C-E and NGC-20-CL-E Self-regulating Field-mountedheating cable Electronic heat-tracing control unit Product overview The DigiTrace NGC-20 is an electronic heat-tracing control unit featuring the benefits of local control

More information

REA 105 Arc Protection Module. Operator s Manual

REA 105 Arc Protection Module. Operator s Manual REA 105 1MRS 751005-MUM Issued: 20.04.1998 Version: B2/26.5.2000 Checked: Approved: REA 105 We reserve the right to change data without prior notice. Contents: 1. General...4 1.1. Features...4 2. Safety...5

More information

Sentry G3 Machinery Protection Monitor

Sentry G3 Machinery Protection Monitor TECHNICAL INFORMATION Sentry G3 Machinery Protection Monitor CONDITION MONITORING SOLUTIONS The Sentry G3 Machinery Protection Monitor is a high performance signal conditioning unit; providing a universal

More information

ATSTORM v2. The sensor with FCES technology is connected to the interface with a communication cable.

ATSTORM v2. The sensor with FCES technology is connected to the interface with a communication cable. ATSTORM v2 ATSTORM v2 is a storm detector that measures the environmental electric field. It is fully automatic, without mobile parts, robust and highly reliable The storm detector ATSTORM v2 basic configuration

More information

Item Number Description Price. Accessories " Diesel/Water/Waste tank sender $ Battery temperature sensor $2.22

Item Number Description Price. Accessories  Diesel/Water/Waste tank sender $ Battery temperature sensor $2.22 DIGITAL Vessel Monitoring 1800 Monitor Monitor includes head unit, surface mount bezel, surface mount gasket, DC current shunt 8255, AC current transformer 8256, battery temperature sensor 1820, connectors,

More information

UDC100 Universal Digital Controller Specifications

UDC100 Universal Digital Controller Specifications UDC100 Universal Digital Controller Specifications 51-52-03-29 November 1999 Overview The UDC100 Universal Digital Controller is a microprocessor-based 1/4 DIN low cost temperature controller. It combines

More information

Fire & Security Alarm Systems

Fire & Security Alarm Systems Fire & Security Alarm Systems By Vedard Security www.vedard.com Part 1 Laying Pipeline 1. Common pipeline material Electric tube pipe contains galvanized steel pipe, welded steel pipe, JDG steel pipe,

More information

Vocia VACIE. Reference Guide

Vocia VACIE. Reference Guide Vocia VACIE Reference Guide Document Revision 1.2.3, August 2015 Biamp Systems 9300 SW Gemini Drive Beaverton, Oregon 97008, U.S.A. (503) 641-7287 www.biamp.com INTRODUCTION... 3 SECTION 1... 4 VACIE CONFIGURATION...

More information

SPECIFICATION: AlarmLine TM INTELLIGENT LINEAR HEAT DETECTION

SPECIFICATION: AlarmLine TM INTELLIGENT LINEAR HEAT DETECTION 1. GENERAL SPECIFICATION 1.1 The contractor shall provide an Intelligent AlarmLine Linear Heat Detection System to perform the following functionality: A. Fire Alarm, Supervisory and Trouble-Event Initiation

More information

Software Version 2.01 LEVEL MONITOR MODEL 220

Software Version 2.01 LEVEL MONITOR MODEL 220 Software Version 2.01 LEVEL MONITOR MODEL 220 19 April 2000 CONTENTS 1. Introduction 1 1.1 Model Number Designation 2 1.2 Intrinsic Safety Considerations 3 2. Specification 4 3. Operation 6 3.1 Display

More information

AlarmLine Addressable Linear Heat Detector

AlarmLine Addressable Linear Heat Detector Line Addressable Linear Heat Detector P/N 7-0001-00 Effective: March 2008 K-7-02 FEATURES UL Listed FM Approved CSFM MEA (pending) Low-cost interface between Line sensor cable and control panel accepting

More information

PMD2 Plus ENHANCED WALK-THROUGH MULTI-ZONE METAL DETECTOR. Threat Detection through Electromagnetics. Superior Detection and Throughput

PMD2 Plus ENHANCED WALK-THROUGH MULTI-ZONE METAL DETECTOR. Threat Detection through Electromagnetics. Superior Detection and Throughput ENHANCED WALK-THROUGH MULTI-ZONE METAL DETECTOR Superior Detection and Throughput Very High Discrimination of Non-Threat Items Compliant with the strictest Security Standards for weapons detection 60 localization

More information

G.M. Advanced Fencing & Security Technologies Ltd

G.M. Advanced Fencing & Security Technologies Ltd GM Advanced Fencing & Security Technologies Ltd V-ALERT Perimeter Security Intrusion Detection System INSTALLATION MANUAL V2 GM Advanced Fencing & Security Technologies Ltd 14 Taas St PO Box 2327 Industrial

More information

ADPRO PRO-E Series. Tel / PERIMETER PIR

ADPRO PRO-E Series. Tel / PERIMETER PIR ADPRO PRO-E Series Product Highlights PRO E-Series detectors deliver exceptional savings of time and total cost of ownership. Designed to be compliant to pren 50606 Grade 3 IP65-rated housing for all models

More information

Compact Module. Category 6A FTP Cabling System 1.1

Compact Module. Category 6A FTP Cabling System 1.1 Updated 24/09/12 Compact Module Cat 6A performance Suitable for 10-Gigabit Ethernet Ultra-slimline design Euro style module Interchangeable with other Euro Modules and blanks Individually QA tested Easy

More information

Electromagnetic Compatibility of Alarm Systems

Electromagnetic Compatibility of Alarm Systems Electromagnetic Compatibility of Alarm Systems Jan VALOUCH Tomas Bata University in Zlin, Faculty of Applied Informatics, Nad Stráněmi 4511, 76005, Zlín, Czech Republic valouch@fai.utb.cz. Abstract. Alarm

More information

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS... SECTION Table of Contents SECTION 1 INTRODUCTION...................... 1.1 Description............................... 1.2 Features................................. 1.3 Models..................................

More information

Annunciator Unit SACO 16 D1. Product Guide

Annunciator Unit SACO 16 D1. Product Guide Issued: Aprill 1999 Status: Updated Version: C/20.03.2006 Data subject to change without notice Features Flexible, field-customizable 16-channel annunciator unit Alarm channels activated by normally open

More information

VACIE REFERENCE GUIDE REVISION 1.2.6

VACIE REFERENCE GUIDE REVISION 1.2.6 VACIE REFERENCE GUIDE REVISION 1.2.6 November 2016 INTRODUCTION... 3 SECTION 1... 4 VACIE CONFIGURATION... 4 Communications... 4 Vocia VACIE Devices... 4 Vocia Support devices:... 5 Power Supply and Network

More information

More Precision. indusensor // Linear inductive displacement sensors

More Precision. indusensor // Linear inductive displacement sensors More Precision indusensor // Linear inductive displacement sensors 18 Long-stroke sensors for hydraulics & pneumatics indusensor EDS - Measurement ranges 75... 630mm - Linearity ±0.3% FSO - Integrated

More information

ACTIVE INFRARED BARRIER

ACTIVE INFRARED BARRIER Although PROTECH provides high security indoor intrusion sensors for the military and government markets, our specialty is outdoor protection. Since we first introduced our PIRAMID outdoor dual technology

More information

YOUR PARTNER IN FIRE & GAS DETECTION

YOUR PARTNER IN FIRE & GAS DETECTION YOUR PARTNER IN FIRE & GAS DETECTION OGGIONI s.a.s. Via Lavoratori Autobianchi, 1 - P.T.B. Edif.13/O - 20832 Desio (MB) Italy Tel.+39 0362 629135 Fax. +39 0362 622531 www.oggionisas.com - info@oggionisas.com

More information

Panel Mounted Fault Annunciator Series

Panel Mounted Fault Annunciator Series Panel Mounted Fault Annunciator Series BSM / USM Panel-mounted fault annunciator Annunciators for panel mounting with,,,, 0 and signal inputs Storage of the last state of inputs and sequence in the case

More information

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw SPECIFICATION GUIDE NEOSYS Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw Air-to-water Heat Pump for outdoor installation (NAH) Nominal cooling capacity:

More information

M5800 Pressure Transducer with Rotatable Display

M5800 Pressure Transducer with Rotatable Display Pressure Transducer with Rotatable Display SPECIFICATIONS Wide Temperature Range Compact Variety of Pressure Ports and customized Electrical Configurations FEATURES CE Compliance Reverse Polarity Protection

More information

Open-area Smoke Imaging Detection (OSID)

Open-area Smoke Imaging Detection (OSID) Open-area Smoke Imaging Detection (OSID) www.xtralis.com/osid Large, open spaces warehouses, airports, train stations, stadiums and shopping malls pose unique challenges to reliable fire detection due

More information