PRODUCT CATALOGUE Norröna

Size: px
Start display at page:

Download "PRODUCT CATALOGUE Norröna"

Transcription

1 PRODUCT CATALOGUE Norröna

2 Table of contents MARINE AND OFFSHORE CABLES 1 TOXFREE XZ1-K (AS) - 0.6/1 kv 1 TOXFREE MARINE XO2TCuZ1-K (AS) - 150/250 V 5 4x2xAWG 24/1 CAT6 S/FTP LSZH-SHF1 - Black 7 TOXFREE XZ1-K (AS+) IEC ,6/1 kv 10

3 Ship cables - halogen free TOXFREE XZ1-K (AS) - 0.6/1 kv Application: TOXFREE XZ1-K (AS) is a series of unique toxfree installation cables. The cables are designed as exible installation cables. They are suited for all use in street lights, public places, power stations, industry and building installations. They are also very suitable for installations where exible connections are needed such as in a motor, generator and similar. Suitable for bricking. The cable is double insulated. Construction: Conductor: Electrolytic annealed Cu, class 5 Insulation: XLPE Conductor color: According to HD 308 Please notice that dimensions marked with ** are with white numbered conductors Inner sheath: Thermoplastic polyole n (TPO) Outer sheath: Extra exible halogen free compound, meter marked, UV resistant, black Technical data: Working temperature: -15 C to +90 C Rated voltage: 0.6/1 kv Bend radius: <25 mm 2 4 x cable diameter >25 mm 2 6 x cable diameter Technical comments: Current value A is at 45 C Approvals: IEC , IEC , IEC , IEC , IEC , IEC , IEC , IEC , CE, RoHS, ABS, Bureau Veritas, DNV, Lloyd's Register 1

4 Ship cables - halogen free TOXFREE XZ1-K (AS) - 0.6/1 kv Properties and installation: For use in cable trays For use in wind turbines Bending radius 6 x cable diameter Fire retardant acc. to IEC For use in switchboards Flame retardant acc. to IEC Flexible Halogen free Can lay in tubes Can be buried Can be immersed into water Low emission of corrosive gases acc. to IEC Low smoke emission during re acc. to Max. working temp. +90 C Max. short circuit temp C Meter marked Environmentally friendly Min. working temperature -40 C Oil resistant Oil and grease resistant Resistance towards oil and chemicals Abrasion resistant For permanent outdoor installation Impact resistance: medium For industrial use For industrial mobile use For use on ships For emergency circuits Withstands freezing Withstands moisture Outdoor decommissioning UV-resistant Water resistant Suited for public places Suited for wall attachment Suitable for bricking 2

5 Ship cables - halogen free TOXFREE XZ1-K (AS) - 0.6/1 kv SKU EAN Dimension (mm²) Current Value (A) Winding Diameter (mm)* Weight (kg/km)* x2,5 25 D./Cut 5, x4 35 D./Cut 5, x6 46 D./Cut 6, x10 64 D./Cut 7, x16 88 D./Cut 8, x D./Cut 10, x D./Cut 11, x D./Cut 13, x D./Cut 15, x D./Cut 17, x D./Cut 19, x D./Cut 21, x D./Cut 23, x D./Cut 26, G G D./Cut 26, x D./Cut 29, x D./Cut 34, x1,5 23 D./Cut 8, x2,5 31 D./Cut 9, x4 43 D./Cut 10, x6 55 D./Cut 11, x10 75 D./Cut 13, x D./Cut 15, x1,5 23 D./Cut 8, G G1,5 23 D./Cut 8, x2,5 31 D./Cut 9, G G2,5 31 D./Cut 9, x4 43 D./Cut 10, x6 55 D./Cut 12, x10 75 D./Cut 14, x16 87 D./Cut 16, x D./Cut 21, x D./Cut 24, x D./Cut 27, x D./Cut 30, x D./Cut 36, x D./Cut 40, x D./Cut 45, x D./Cut 50, x D./Cut 57, x1,5 20 D./Cut 9, G G1,5 20 D./Cut 9, x2,5 28 D./Cut 10, G G2,5 28 D./Cut 10, x4 37 D./Cut 12, x6 47 D./Cut 13, x10 65 D./Cut 16, x16 87 D./Cut 18,

6 Ship cables - halogen free TOXFREE XZ1-K (AS) - 0.6/1 kv SKU EAN Dimension (mm²) Current Value (A) Winding Diameter (mm)* Weight (kg/km)* x D./Cut 23, G G D./Cut 23, x D./Cut 25, G G D./Cut 25, G D./Cut 31, G G D./Cut 35, G G D./Cut 40, G D./Cut 44, G G D./Cut 50, x D./Cut 63, G G D./Cut 63, ** x1,5 20 D./Cut 10, G G1,5 20 D./Cut 10, G G2,5 28 D./Cut 11, G4 37 D./Cut 13, G6 47 D./Cut 15, G10 65 D./Cut 17, G16 87 D./Cut 20, G G D./Cut 29, G G D./Cut 33, G G D./Cut 34, G G D./Cut 38, ** x1,5 11 D./Cut 11, ** x2,5 15 D./Cut 12, ** x1,5 9 D./Cut 14, ** x1,5 8 D./Cut 17, ** x1,5 7 D./Cut 18,8 531 * The values can have small deviations 4

7 Ship cables - halogen free TOXFREE MARINE XO2TCuZ1-K (AS) - 150/250 V Application: XO2TCuZ1-K (AS) is a highly exible cable for permanent installation on ships and o shore units. The cable is particularly suitable for power circuits where shielding is required, or areas which requires additional protection against possible shock. The cable material is halogen free, has low smoke emission and is re retardant. Construction: Conductor: Electrolytic annealed Cu, class 5 acc. to IEC 60228:2004 Insulation: LSZH XLPE Conductor color: Twisted pair (blue/white), numbered Screen: Overall screen of aluminum. Polyester tape with Cu drain wire. Cu wire braid armour over the collective screen. Outer sheath: LSZH thermoplastic polyole ne SHF1, grey Technical data: Working temperature: -40 C to +90 C Rated voltage: 150/250 V Bend radius: 4 x cable diameter Technical comments: Short circuit temperature: max 250 C / 5 sec. Approvals: IEC , IEC /351/359, IEC , IEC cat. A, IEC /2, IEC /2, DNV, CE, RoHS Properties and installation: For use in cable trays Bending radius 4 x cable diameter Fire retardant acc. to IEC Electromagnetical ly protected Flame retardant acc. to IEC Flexible Halogen free Can lay in tubes Low emission of corrosive gases acc. to IEC Low smoke emission during re acc. to Max. working temp. +90 C Meter marked Environmentally friendly Min. working temperature -40 C Resistance towards oil and chemicals For permanent outdoor installation Impact resistance: medium For use on ships Outdoor decommissioning Water resistant Suited for public places Suited for wall attachment 5

8 Ship cables - halogen free TOXFREE MARINE XO2TCuZ1-K (AS) - 150/250 V SKU EAN Dimension (mm²) Current Value (A) Winding Diameter (mm)* Weight (kg/km)* x2x0,75 17,1 D./Cut 7, x2x0,75 13,7 D./Cut 11, x2x0,75 11,2 D./Cut 13, x2x0,75 9,2 D./Cut 15, x2x0,75 8,6 D./Cut 20, x2x0,75 7,4 D./Cut 21, x2x0,75 6,5 D./Cut 24,9 795 * The values can have small deviations 6

9 Ship cables - halogen free 4x2xAWG 24/1 CAT6 S/FTP LSZH-SHF1 - Black Application: The cable is used in telecommunication network for transmission of digital and analogical signals up to 250 MHz. Due to its unique design and UV resistance, the cable is suitable for installation in maritime and offshore environments, but it can also be used for industrial use, where demands are made for increased fire safety. The cable is UV resistant, marine approved and paired, individually screened. Construction: Conductor: Insulation: Bare, annealed copper (24 AWG) Cellular PO (1.04 mm) Conductor color: TIA/EIA 568-B Screen: Outer sheath: Braided, annealed tinned copper (55% coverage) Paired, individually screened foil (100% coverage) Black, FR-LSZH Technical data: Working temperature: Technical comments: -40 o C to +85 o C Frequency range: MHz Impedans: 100 Ω Transfer impedance: grade 1 Coupling attenuation: type 1 DC-modstand: 90 Ω/km Max. resistance unbalance: 2% Capacitance unbalance: 1.2 pf/m max. Velocity of propagation: 78% Propagation delay skew: max. 25 ns/100 m Dielectric strength: 700 V/minut Dielectric strength to shield: 700 V/minut Insulation resistance (min.): 5 GΩ x km Tensile strength: max. 130 N/mm 2 Approvals: IEC , IEC , IEC , IEC 61156, IEEE 802.3at (PoE+), ISO/IEC 11801, RoHS /65/EU, IEC , IEC , IEC , IEC /2, IEC /2, UL 1581 VW-1 7

10 Ship cables - halogen free 4x2xAWG 24/1 CAT6 S/FTP LSZH-SHF1 - Black Properties and installation: Flame retardant acc. to IEC Fire retardant acc. to IEC (CAT-A) Fire retardant acc. to IEC Low emission of corrosive gases acc. to IEC Low smoke emission during re acc. to Max. working temp. +85 C Min. working temperature -40 C Halogen free UV-resistant For use on ships For industrial use Environmentally friendly For use on oil rigs For use in homes For use in wind turbines Electromagnetical ly protected Suited for public places Meter marked For use in cable trays Water resistant Withstands moisture Withstands freezing Can lay in tubes Outdoor decommissioning For permanent outdoor installation Oil resistant 8

11 Ship cables - halogen free 4x2xAWG 24/1 CAT6 S/FTP LSZH-SHF1 - Black SKU EAN Dimension Current Value Winding Diameter Weight (mm²) (A) (mm)* (kg/km)* x2xAWG24 - D./Cut 7,2 58 * The values can have small deviations 9

12 Ship cables - reproof TOXFREE XZ1-K (AS+) IEC ,6/1 kv Application: XZ1-K (AS+) IEC is suited for xed installations on ships and o shore units in all locations. The cable material is halogen free, has low fumes emission, re retardant and re resistant. The cable are especially suitable for the installation in ships in power, lighting and control circuits. Construction: Conductor: Electrolytic annealed Cu, class 5 Insulation: Mica tape + halogen free XLPE Conductor color: 1 conductor: transparent 2 conductors: blue, brown 3 conductors: brown, black, grey 4 conductors: brown, black, grey, blue 5 conductors: with white numbers Filling sheath: If needed, the ller is thermoplastic polyole n of natural colour Outer sheath: Halogenfree thermoplastic polyole n type SHF1, orange Technical data: Working temperature: -40 C to +90 C Rated voltage: 0.6/1 kv Bend radius: < or equal with 25 mm: 4 x cable diameter > or equal with 25 mm: 6 x cable diameter Technical comments: Short circuit temp.: max 250 C / 5 sec. Current value A is meassured at 45 C CPR-klassi cering: Rekvirer DoP på dop@scankab.dk Approvals: EN 50575, IEC , IEC , IEC , IEC , IEC , IEC , IEC , IEC , CE, RoHS, Bureau Veritas, DNV, Lloyd's Register Properties and installation: For use in cable trays Bending radius 4 x cable diameter Bending radius 6 x cable diameter Flame retardant acc. to IEC Fire retardant acc. to IEC Flexible Operation secured acc. to IEC Halogen free Can lay in tubes Low emission of corrosive gases acc. to IEC Low smoke emission during re acc. to Max. working temp. +90 C Max. short circuit temp C Environmentally friendly Min. working temperature -40 C Resistance towards oil and chemicals Impact resistance: medium For use on ships Outdoor decommissioning Water resistant Suited for public places Suited for wall attachment 10

13 Ship cables - fireproof TOXFREE XZ1-K (AS+) IEC ,6/1 kv SKU EAN CPR Dimension (mm²) Current Value (A) Winding Diameter (mm)* Weight (kg/km)* C ca -s1,d1,a1 1x2,5 25 D./Cut 5, C ca -s1,d1,a1 1x4 35 D./Cut 6, C ca -s1,d1,a1 1x6 46 D./Cut 7, C ca -s1,d1,a1 1x10 64 D./Cut 7, C ca -s1,d1,a1 1x D./Cut 10, C ca -s1,d1,a1 1x D./Cut 12, C ca -s1,d1,a1 1x D./Cut 13, C ca -s1,d1,a1 1x D./Cut 15, C ca -s1,d1,a1 1x D./Cut 17, C ca -s1,d1,a1 1x D./Cut 19, C ca -s1,d1,a1 1x D./Cut 21, C ca -s1,d1,a1 1x D./Cut 24, C ca -s1,d1,a1 1x D./Cut 27, C ca -s1,d1,a1 1x D./Cut 30, C ca -s1,d1,a1 2x1,5 23 D./Cut 9, C ca -s1,d1,a1 2x2,5 31 D./Cut 10, C ca -s1,d1,a1 2x4 43 D./Cut 11, C ca -s1,d1,a1 2x6 55 D./Cut 12, C ca -s1,d1,a1 2x10 75 D./Cut 14, C ca -s1,d1,a1 2x D./Cut 16, C ca -s1,d1,a1 3x1,5 23 D./Cut 10, G - C ca -s1,d1,a1 3G1,5 23 D./Cut 10, C ca -s1,d1,a1 3x2,5 31 D./Cut 11, C ca -s1,d1,a1 3x4 43 D./Cut 12, C ca -s1,d1,a1 3x6 55 D./Cut 13, C ca -s1,d1,a1 3x10 75 D./Cut 15, C ca -s1,d1,a1 3x16 87 D./Cut 17, C ca -s1,d1,a1 3x D./Cut 22, C ca -s1,d1,a1 3x D./Cut 25, C ca -s1,d1,a1 3x D./Cut 28, C ca -s1,d1,a1 3x D./Cut 31, C ca -s1,d1,a1 3x D./Cut 37, C ca -s1,d1,a1 3x D./Cut 41, C ca -s1,d1,a1 3x D./Cut 46, C ca -s1,d1,a1 3x D./Cut 52, C ca -s1,d1,a1 3x D./Cut 58, C ca -s1,d1,a1 4x1,5 20 D./Cut 11, G - C ca -s1,d1,a1 4G1,5 20 D./Cut 11, C ca -s1,d1,a1 4x2,5 28 D./Cut 12, G - C ca -s1,d1,a1 4G2,5 28 D./Cut 12, C ca -s1,d1,a1 4x4 37 D./Cut 13, C ca -s1,d1,a1 4x6 47 D./Cut 14, C ca -s1,d1,a1 4x10 65 D./Cut 17, C ca -s1,d1,a1 4x16 87 D./Cut 20, C ca -s1,d1,a1 4x D./Cut 25, C ca -s1,d1,a1 4x D./Cut 27, C ca -s1,d1,a1 4x D./Cut 32, C ca -s1,d1,a1 4x D./Cut 37,

14 Ship cables - fireproof TOXFREE XZ1-K (AS+) IEC ,6/1 kv SKU EAN CPR Dimension (mm²) Current Value (A) Winding Diameter (mm)* Weight (kg/km)* C ca -s1,d1,a1 4x D./Cut 42, C ca -s1,d1,a1 4x D./Cut 46, C ca -s1,d1,a1 4x D./Cut 51, C ca -s1,d1,a1 4x D./Cut 57, C ca -s1,d1,a1 4x D./Cut 65, C ca -s1,d1,a1 5x1,5 20 D./Cut 12, G - C ca -s1,d1,a1 5G1,5 20 D./Cut 12, C ca -s1,d1,a1 5x2,5 28 D./Cut 13, G - C ca -s1,d1,a1 5G2,5 28 D./Cut 13, C ca -s1,d1,a1 5x4 37 D./Cut 14, C ca -s1,d1,a1 5x6 47 D./Cut 16, C ca -s1,d1,a1 5x10 65 D./Cut 19, C ca -s1,d1,a1 5x16 87 D./Cut 22, C ca -s1,d1,a1 5x D./Cut 27, C ca -s1,d1,a1 5x D./Cut 30, C ca -s1,d1,a1 5x D./Cut 36, C ca -s1,d1,a1 7x1,5 11 D./Cut 12,9 240 * The values can have small deviations 12

15 SCANKAB CABLES A/S DANMARK MALERVÆNGET 3 DK-5560 AARUP DANMARK TLF.: SCANKAB CABLES AB SVERIGE BRISVÄGEN 3 SE NYHAMNSLÄGE SVERIGE TLF.: SCANKAB CABLES AS NORGE ORSTADVEGEN 130 NO-4353 KLEPP STASJON NORGE TLF.:

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission ADDISON Flame Retardant CAT5e Data Cables FTX-CAT5e U/UTP4P24 FTX-CAT5e f/utp4p24 FTX-CAT5e sf/utp4p24 LSZH Outer Aluminium/Polyester Tape Solid Copper Conductor PE Insulation Tinned Copper Drain Wire

More information

Caledonian Flame Retardant Coaxial Cables

Caledonian Flame Retardant Coaxial Cables Caledonian Flame Retardant Coaxial Cables www.caledonian-cables.co.uk www.addison-cables.com Flame Retardant RG59 Coaxial cables LSZH Outer Sheath Tinned Copper Braid Aluminium+polyester/Aluminium Tape

More information

FIRE RESISTANT CABLES

FIRE RESISTANT CABLES Conducting Value The Last Cable Standing FIRE RESISTANT CABLES 100/7b ISO 9001:2008 Certificate No. CS1-249 MANAGEMENT SYSTEMS Assessed to ISO 9001:2008 Cert/LPCB ref. 217 GOST ISO 9001-2011 (ISO 9001:2008)

More information

Flame Retardant Overall Screened Instrumentation Cables (multicore)

Flame Retardant Overall Screened Instrumentation Cables (multicore) Flame Retardant Overall Screened Instrumentation Cables (multicore) RE-2X(St)H RE-2X(St)HSWAH LSZH Outer Sheath Tinned Copper Drain Wire LSZH Inner Sheath XLPE Insulation Plain Annealed Copper Aluminium/polyester

More information

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour. 67 POWERFLEX RV-K POWERFLEX RV-K Industrial flexible cable for power transmission. 1 IEC 60502-1 - UNE 21123-2 DESIGN 1. Conductor 2 Electrolytic copper, class 5 (flexible), based on EN 60228 and IEC 60228.

More information

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design. ADDISON Flame Retardant RG59 B/U Coaxial cables Plain copper wire braid PE Solid Bare Copper PVC Outer Sheath APPLICATION The cables are designed for CCTV, security, smoke detection and evacuation monitoring

More information

Caledonian Fire resistant Coaxial Cables

Caledonian Fire resistant Coaxial Cables Caledonian Fire resistant Coaxial Cables www.caledonian-cables.net www.addison-cables.com Fire resistant rg59 b/u Coaxial Cables RG59 B/U FR LSZH Sheath Fire Resistant Tape Copper Clad Steel/Bare Copper

More information

Shipboard & Offshore Cables

Shipboard & Offshore Cables Shipboard & Offshore Cables Shipboard & Offshore Cables Páge Introduction 3 Power Cables XL / XL-FR 5 XC4L / XC4L-FR 6 XLC4L / XLC4L-FR 7 Instrumentation cables XHL / XHL-FR 8 XOL / XOL-FR 9 XHC4L / XHC4L-FR

More information

Compact Module. Category 6A FTP Cabling System 1.1

Compact Module. Category 6A FTP Cabling System 1.1 Updated 24/09/12 Compact Module Cat 6A performance Suitable for 10-Gigabit Ethernet Ultra-slimline design Euro style module Interchangeable with other Euro Modules and blanks Individually QA tested Easy

More information

Catalogue Telecommunication Cables INTRODUCCIÓN

Catalogue Telecommunication Cables INTRODUCCIÓN Catalogue Telecommunication Cables INTRODUCCIÓN Conductores Tecnológicos S.A. www.contecsa.es Index of Cables Page Introduction 3 EAP / EAP-R 4 EAPSP / EAPSP-R 5 ISP / ICP 6 Conductores Tecnológicos S.A.

More information

High Performance LSZH Fire Resistant Cable

High Performance LSZH Fire Resistant Cable High Performance LSZH Fire Resistant Cable www.cavicel.com 104/2 FIRECEL SR 114H is the long and well established CAVICEL fire resistant cable in the market, since many years. These cables are third party

More information

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission Flame Retardant RS485 Databus Cables Copper Wire Braid(optional) Individual AL/Polyester Tape(optional) Foam PE/Foam skin PE. Stranded Tinned Copper AL/Polyester Tape With Tinned Copper Drain Wire LSZH

More information

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores)

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores) Caledonian Flame Retardant Power & Control Cables www.caledonian-s.co.uk www.addison-s.com 600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores) FTX400 1RZ1MZ1-R (CU/XLPE/LSZH/DSTA/LSZH

More information

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+) Page 1 / 7 Construction and tests. Standards: UNE 211025 Compliance with the Low Voltage Directive (LVD): 2014/35 / EU Construction Products Regulation (CPR) - Regulation (EU) Nº 305/2011: Reaction to

More information

INTRODUCTION. Our diverse range of world-class Specialty Insulated Wires and Cablesinclude: LV Cables -

INTRODUCTION. Our diverse range of world-class Specialty Insulated Wires and Cablesinclude: LV Cables - MARINE CABLES Your Power Partner on the Seas INTRODUCTION We, a member of the Al-Bahja Group of Companies, are an ISO:900:2008 BASEC, UK certified integrated quality producer of LV and MV Cables, Wires&

More information

Multi-Core Fire Resistant Cable

Multi-Core Fire Resistant Cable Fire Resistant Cables / Multi-Core Fire Resistant Cable Approved to UL 444, Zeta ZFP series cables have received UL approval for standard applications. Standards Alarm Cable Z UL 444 Approval CMH Rated

More information

Caledonian fire Resistant signal & Data cables

Caledonian fire Resistant signal & Data cables fire Resistant signal & Data cables www.addison-tech.com fire Resistant Rs485 Databus cables Copper Wire Braid(optional) Individual AL/Polyester Tape(optional) Mica Glass Tape+PE/PE+Silicone Rubber Insulation

More information

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores) 600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores) FFX400 1SZ1-R(PH60)(CU/SR/LSZH 600/1000V Class 2) FFX400 1SZ1-F(PH60)(CU/SR/LSZH 600/1000V Class 5) Silicone Rubber Insulation Plain

More information

Telecommunication Cables

Telecommunication Cables Telecommunication Cables Telecommunication Cables Introduction 3 EAP / EAP-R 4 EAPSP / EAPSP-R 5 ISP / ICP 6 Page ELECWIRES 2 www.elecwires.es INTRODUCCIÓN Telecommunication Cables Telephone cables suitable

More information

Catalogue Power Cables

Catalogue Power Cables Catalogue Power Cables Conductores Tecnológicos S.A. www.contecsa.es Index of Cables Page Introduction 13 RV 14 RVMV 15 RVSV 16 RVFV 17 Conductores Tecnológicos S.A. 2 www.contecsa.es INTRODUCTION Power

More information

SPECIAL ELECTRICAL AND OPTICAL CABLES

SPECIAL ELECTRICAL AND OPTICAL CABLES SPECIAL ELECTRICAL AND OPTICAL CABLES INTRODUCTION The new high-speed trains and the sensible increase of the traffic, with congested lines, is the result of the latest development of the rail sector.

More information

OFFSHORE CABLES. Top Cable Central Headquarters. Leonardo Da Vinci, number Rubí (Barcelona) Spain

OFFSHORE CABLES.   Top Cable Central Headquarters. Leonardo Da Vinci, number Rubí (Barcelona) Spain Top Cable Central Headquarters Leonardo Da Vinci, number 1 08191 Rubí (Barcelona) Spain OFFSHORE CABLES Tel +4 9 586 21 78 +4 9 586 21 68 Fax +4 9 586 21 65 sales@topcableoffshoremarine.com http://www.topcableoffshoremarine.com

More information

Power Cables. Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7. ELECWIRES 2 Page

Power Cables. Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7. ELECWIRES 2  Page Power Cables Power Cables Page Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7 ELECWIRES 2 www.elecwires.es INTRODUCTION Power Cables Power cables for electrical installations, domestic & industrial, specifically

More information

DNVGL-CP-0401 Edition February 2016

DNVGL-CP-0401 Edition February 2016 CLASS PROGRAMME Type approval DNVGL-CP-0401 Edition February 2016 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD

More information

Photovoltaic Cables EN H1Z2Z2-K

Photovoltaic Cables EN H1Z2Z2-K Photovoltaic Cables EN 50618 H1Z2Z2-K COMPANY PROFILE Caledonian, established in 1978, offers one of the most complete lines of fiber and copper cabling system solutions with over hundreds of different

More information

CATEGORY 6A FTP RJ45 SOLUTION

CATEGORY 6A FTP RJ45 SOLUTION CATEGORY 6A FTP RJ45 SOLUTION Clipsal titanium Patch Cord Clipsal titanium LSZH Patch Cord Clipsal titanium Keystone Jacks Clipsal titanium Modular Jacks Clipsal titanium Patch Panels Clipsal titanium

More information

DNVGL-CP-0399 Edition March 2016

DNVGL-CP-0399 Edition March 2016 CLASS PROGRAMME Type approval DNVGL-CP-0399 Edition March 2016 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD

More information

The Quality Connection. BETAflam Fire Resistant Safety Cables

The Quality Connection. BETAflam Fire Resistant Safety Cables The Quality Connection BETAflam Fire Resistant Safety Cables BETAflam Contact Your personal customer number To offer you a more efficient service, we kindly ask you to mention your personal customer number

More information

Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation. Technical Data Sheet BETAflam Solar 125 flex UL 4703 Description Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

More information

DNVGL-CP-0402 Edition February 2016

DNVGL-CP-0402 Edition February 2016 CLASS PROGRAMME Type approval DNVGL-CP-0402 Edition February 2016 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD

More information

Catalogue. Instrumentation & Control Cables

Catalogue. Instrumentation & Control Cables Catalogue Instrumentation & Control Cables Conductores Tecnológicos S.A. www.contecsa.es Index of Cables Page Introduction 3 Instrumentation VOV 4 VHOV 5 VOVMV 6 VHOVMV 7 Control RV 8 RZ1C3Z1 9 Conductores

More information

Table of Contents. TELE-FONIKA KABLE SA (DMCC Branch). 4 TELE-FONIKA Kable Group 6 FLAME-X 950 SERIES 1 11 FLAME-X 950 SERIES 2

Table of Contents. TELE-FONIKA KABLE SA (DMCC Branch). 4 TELE-FONIKA Kable Group 6 FLAME-X 950 SERIES 1 11 FLAME-X 950 SERIES 2 FLAME-X 950 TELE-FONIKA KABLE SA (DMCC Branch). Table of Contents is the Regional Middle East Sales Office of Tele-Fonika Kable S.A. from Poland, 4-th largest manufacturer of electric cables and wires

More information

CABLES FOR ALARM AND SAFETY SYSTEMS

CABLES FOR ALARM AND SAFETY SYSTEMS CABLES FOR ALARM AND SAFETY SYSTEMS 2 IT S ALL ABOUT RELIABILITY. It is always important to choose high quality cables, especially when it comes to alarms and safety systems. Even small and seemingly insignificant

More information

CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES

CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES Gexol CIR Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL Index

More information

SAS Security and Alarm Safety Cables

SAS Security and Alarm Safety Cables CABLES Security and Alarm Safety Cables Security and Alarm Safety Cables LOW SMOKE ZERO HALOGEN The right range of cables for modern building installations e-catalogue 203/4 Flexible solutions for commercial,

More information

Introduction.

Introduction. Introduction The safety of occupants and users of public, commercial and industrial premises is of paramount importance. One important safety feature is the appropriate use of fire performance cables for

More information

BS /1000V XLPE Insulation LSZH Sheath Cables

BS /1000V XLPE Insulation LSZH Sheath Cables BS 8573 600/1000V XLPE Insulation LSZH Sheath Cables Caledonian www.addison-cables.com Company Profile Caledonian & Addison, branded under Caledoniea & Addimax, established in 1978, offers one of the most

More information

CIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES

CIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES CIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES Gexol CIR ARCTIC GRADE (AG) Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by

More information

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red Indoor/Outdoor steel tape armoured (CST) double LSHF-FR sheathed optical cable with 2 24 fibres. VDE: A/I-DQ(ZN)H(SR)H 3rd party verification of the fire tests by BUREAU VERITAS December 2014 OFC-UT-CST

More information

Traction Cable Radox 3 GKW

Traction Cable Radox 3 GKW General Properties : Excellent high temperature, low temperature, ozone and weathering resistance, zero halogen, flame retardant, solder iron resistant, easily strippable, flexible. Application : Single

More information

OIL & GAS INDUSTRY OTHER INDUSTRIES

OIL & GAS INDUSTRY OTHER INDUSTRIES For ATEX Areas OIL & GAS INDUSTRY OTHER INDUSTRIES OIL & GAS INDUSTRY POTENTIALLY HAZARDOUS Class I GASES VAPORS LIQUIDS Petrosumsave Zone 0 An area in which an explosive mixture is continuously present,

More information

UNIKA Universal Cable Cable Specialist

UNIKA Universal Cable Cable Specialist UNIKA Universal Cable Cable Specialist Committed to Quality At ÜNİKA, quality is an intrinsic part of our Operations. Our comprehensive product and System certification not only are mandatory requirements

More information

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable. Product Specification 108-93018 25/Aug/2011 Rev H Copper LAN cable 1. SCOPE 1.1. Content This specification describes the general requirements for AMP NETCONNECT* copper LAN cable. 2. APPLICABLE DOCUMENTS

More information

CIR AG Power Cables. CIR AG Control Cable. CIR Type VFD Cable. CIR AG Ratings & Approvals. n UL Listed as Type TC-ER n UL Listed as TC-ER-HL (E123629)

CIR AG Power Cables. CIR AG Control Cable. CIR Type VFD Cable. CIR AG Ratings & Approvals. n UL Listed as Type TC-ER n UL Listed as TC-ER-HL (E123629) Gexol CIR ARCTIC GRADE (AG) Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL n Shortest Lead Times Standard 8-10

More information

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore)

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore) 600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore) FGD400 1RV-R (CU/XLPE/PVC 600/1000V Class ) FGD400 1RVMV-R (CU/XLPE/PVC/SWA/PVC 600/1000V Class ) PVC Outer Sheath Plain Annealed

More information

fire resistant cables

fire resistant cables Building Technology fire resistant cables Special electrical and optical cables www.tecnikabel.com Special electrical and optical cables 2 INTRODUCTION Structured cabling solutions. Tecnikabel can provide

More information

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE Draka, the world s mo When it comes to specifying fire performance cables, zero halogen building wires and power cables, you have to choose products

More information

Firecel Safety Cables

Firecel Safety Cables 103/7 Firecel Safety Cables Low Smoke - Zero Halogen www.cavicel.com Firecel Safety Cables Low Smoke - Zero Halogen Over the last 30 years CAVICEL has developped a deep experience in studying, designing

More information

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE Draka, the world s most trusted cable brand When it comes to specifying fire performance cables, zero halogen building wires and power cables, you have

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61156-6 First edition 2002-03 Multicore and symmetrical pair/quad cables for digital communications Part 6: Symmetrical pair/quad cables with transmission characteristics up

More information

S Low loss coax cables with foamed PE

S Low loss coax cables with foamed PE S Low loss coax cables with foamed PE Cable design Electrical cable data Impedance () 50 Capacitance 82 pf/m Velocity of signal propagation 82 % of the speed of light Epsilon r 1.5 Signal delay 4.1ns/m

More information

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1 Page 1/9 Illustrations Principle diagram See enlarged drawings at the end of document Product specification connection cable I-V(ZN)HH breakout cable for direct connector termination for indoors and outdoors

More information

Lloyd s Register Type Approval System Test Specification Number 3

Lloyd s Register Type Approval System Test Specification Number 3 Working together for a safer world Lloyd s Register Type Approval System Test Specification Number 3 July 2015 Performance Test Specification for Equipment to be used in Marine Applications: Electric Cables

More information

Total Fire Solutions. Includes BS 8519 and the updated BS :

Total Fire Solutions. Includes BS 8519 and the updated BS : Total Fire Solutions Includes BS 8519 and the updated BS 5266-1:2011 www.aeicables.co.uk Introduction: Total Fire Solutions Power and control cable systems for life safety and fire-fighting applications

More information

Flexible Power Cable DLO

Flexible Power Cable DLO 37-119 Flexible Power Cable DLO 2000 Volts 90 C Diesel Locomotive Cable Limited Smoke (Sizes 2/0 and higher) EP/CPE RHH, RHW-2 Flexible-stranded, tin-coated annealed copper Flame retardant, oil and sunlight

More information

Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive

Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive Illustrations Principle diagram Page 1/7 Product specification installation cable U-DQ(ZN)BH universal fiber optic cable for indoors/outdoors with central or stranded loose tube bend insensitive fiber

More information

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V PHOTOVOLTAIC CABLES PHOTOVOLTAIC CABLES INDEX n AmerSol Dual-Certified (UL / ETL) Photovoltaic Cable 2000V/1500V....................... 2-3 n AmerSol Dual-Certified (UL / ETL) Photovoltaic Cable 2000V/1000V.......................

More information

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE TYPE APPROVAL CERTIFICATE Certificate No: TAE00000GG Revision No: 2 This is to certify: That the Data transmission cables and systems with type designation(s) MGD Cat 3, MGD Cat 5, Cat 5e, MGD cat 6, Cat

More information

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES CORFLEX TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES INDEX Instrumentation Cables - Pairs and Triads (0V*)... 2 - The Original MC-HL Technology In 1958 Canada Wire and Cable, which s now part of Nexans,

More information

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION Fire alarm cables for highest safety requirements TRADITION INNOVATION PASSION Datwyler Datwyler Cabling Solutions is an internationally operating company with its headquarters in Switzerland and affiliates

More information

CAT5E DIRECT BURIAL (FLOODED CORE) 24AWG, UTP, 4 PAIR, SOLID 1000 PULL BOX /CMXF

CAT5E DIRECT BURIAL (FLOODED CORE) 24AWG, UTP, 4 PAIR, SOLID 1000 PULL BOX /CMXF POST CAT5E DIRECT BURIAL (FLOODED CORE) 24AWG, UTP, 4 PAIR, SOLID 1000 PULL BOX PART NUMBER: 059-485/CMXF 1 APPROVALS: MARKETING DATE: THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROPRIETARY TO VERTICAL

More information

Flexflame. Arctic Grade Cables for Extreme Conditions. Photo: Sakhalin Energy Investement Company Ltd.

Flexflame. Arctic Grade Cables for Extreme Conditions. Photo: Sakhalin Energy Investement Company Ltd. Flexflame Arctic Grade Cables for Extreme Conditions Photo: Sakhalin Energy Investement Company Ltd. Linking the future Draka Norsk Kabel is a part of Prysmian Group, a worldwide leader in the cable industry.

More information

Low Smoke Zero Halogen

Low Smoke Zero Halogen Low Smoke Zero Halogen Cable for Marine Applications 621 Time Saver Avenue Harahan, LA 70123 Call Toll Free: (888) 326-5174 Email: marine@summit.com Marine Division summit.com/marine Power and Control

More information

Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES

Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES 37-754 FLAME RETARDANT EP/CPE TYPE TC OR TC-ER POWER CABLE Two Five Conductor + Ground (Two, Three & Four Conductor) 600 V Rated 90 C Conductor*

More information

Power Control Cable Iec

Power Control Cable Iec POWER CONTROL CABLE IEC 60502 1 PDF - Are you looking for power control cable iec 60502 1 Books? Now, you will be happy that at this time power control cable iec 60502 1 PDF is available at our online

More information

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers Features and Benefits Corrugated armor Mechanical protection Low-smoke/zero-halogen (LSZH ) sheath Key life-safety benefit Meets cyclic impact and chemical resistance test Superior performance Tray-rated

More information

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red OFC-UT-CST Fire resistant Armoured Indoor/Outdoor steel tape armoured (CST) double LSHF-FR sheathed optical cable with 2 24 fibres. VDE: A/I-DQ(ZN)H(SR)H 3rd party verification of the fire tests by BUREAU

More information

Data sheet OpDAT mini breakout cable 24x1 OM4 - bend insensitive

Data sheet OpDAT mini breakout cable 24x1 OM4 - bend insensitive Page 1/8 Illustrations Principle diagram See enlarged drawings at the end of document Product specification mini-breakout installation cable U-VQ(ZN)H laser-optimized, bend insensitive fiber UV-resistant,

More information

Core identification code. J-YY...BD Indoor Cable. J-YY...BD Indoor Cable. VDE 0815 Mutual capacitance. J-YY...BD Indoor Cable. Cu conductor 0.

Core identification code. J-YY...BD Indoor Cable. J-YY...BD Indoor Cable. VDE 0815 Mutual capacitance. J-YY...BD Indoor Cable. Cu conductor 0. Indoor cables J-YY...BD Indoor J-Y(ST)Y..LG Indoor Comparable products UNITRONIC J-2Y(ST)Y...ST III BD see page 271 Indoor telephone cables transmit analogue or digital signals In news and communication

More information

Cable technology for highest safety requirements

Cable technology for highest safety requirements Cable technology for highest safety requirements Daetwyler We are a provider of high-grade quality system solutions and services in the areas of structured data cabling, telecom carriers, safety cabling,

More information

Havells Fire Survival Cables

Havells Fire Survival Cables Fire Survival Cables Designed for Critical Installation of National Importance Airports / Thermal Power Plants Metro Rail Projects / Rail Terminals / Nuclear Interstate Bus Terminals / Installation Prone

More information

Comtran Cable. Hub-LINK Cables for Transit Applications

Comtran Cable. Hub-LINK Cables for Transit Applications Comtran Cable Hub-LINK Cables for Transit Applications Overview Hub-LINK rail transit cables are designed to resist the rugged conditions of the underground and at-grade environments, including: Temperature

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK ISO/IEC 17065:2012 to provide product conformity certification Presley Way Crownhill Milton Keynes MK8 0ES Contact: Tracie Hunter Tel: +44 (0)1908 267300 Fax: +44 (0)1908 267255 E-Mail: mail@basec.org.uk

More information

FIRE PERFORMANCE CABLE

FIRE PERFORMANCE CABLE FIRE PERFORMANCE CABLE Manufactured to BS 7629-1 Table 1 Plain Annealed Copper Conductors / Silicone Rubber Insulated / Double Layer of Aluminium/ Polyester Laminated Tapes / Circuit Protective Conductor

More information

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008. BS EN 60332-1-2:2004 Test On Electric And Optical Fibre Cables Under Fire Conditions WF Report Number 177603 Date: 14 th November 2008 Test Sponsor: FTC Fabbrica Trentina Conduttori Srl 0249 Page 2 of

More information

CONTENTS. Introduction Customer Service BS codes of practice BS Fire Performance Cable Selection Guide... 7

CONTENTS. Introduction Customer Service BS codes of practice BS Fire Performance Cable Selection Guide... 7 CONTENTS Page Introduction... 1 Customer Service... 2 BS codes of practice BS 8519... 5 Fire Performance Cable Selection Guide... 7 FlamBICC Introduction...8 FlamBICC 1...10 FlamBICC 2...12 FlamBICC 3...14

More information

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES INDEX Corflex MC-HL Instrumentation - Pairs and Triads (0V*)... 1 - CORFLEX Cables

More information

ENHANCED FIRE PERFORMANCE CABLE

ENHANCED FIRE PERFORMANCE CABLE FIRE PERFORMANCE CABLE Manufactured to BS 7629-1 Table 1 Plain Annealed Copper Conductors / Silicone Rubber Insulated / Glass Fibre Tape / Tinned Copper Circuit Protective Conductor / Double Layer of Copper/Polyester

More information

Fire Resistant Cables

Fire Resistant Cables Fire Resistant Cables Ducab (Abu Dhabi) Factory P.O. Box 9171, Abu Dhabi, UAE Tel: (971-2) 502 7777 Fax: (971-2) 502 7888 email: ducab@ducab.com Ducab Connect P.O. Box 11529, Dubai, United Arab Emirates

More information

FIRE RESISTANT CABLES FP300

FIRE RESISTANT CABLES FP300 FIRE RESISTANT CABLES FP300 Fire resistant LSOH power cables for fixed wiring FIRE RESISTANT CABLES FP300 LPCB Ref No: 077e/01 FP300 > Prysmian FP300 is designed for cabling essential safety circuits associated

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61892-4 First edition 2007-06 Mobile and fixed offshore units Electrical installations Part 4: Cables Commission Electrotechnique Internationale International Electrotechnical

More information

UV RESISTANT ACCORDING TO HD 605 RULE

UV RESISTANT ACCORDING TO HD 605 RULE UV RESISTANT ACCORDING TO HD 605 RULE Faced with increasingly frequent requirements to install outdoor wiring for data and signals, we further developed a special range of cables called: BLUE TOP LINE

More information

Energy Division Heat-shrinkable joints for halogen-free, flame-retardant and fire-resistand cables up to 1 kv

Energy Division   Heat-shrinkable joints for halogen-free, flame-retardant and fire-resistand cables up to 1 kv Energy Division http://energy.tycoelectronics.com Heat-shrinkable joints for halogen-free, flame-retardant and fire-resistand cables up to 1 kv R Heat-shrinkable joints for halogen-free, flame-retardant

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60092-350 Second edition 2001-06 Electrical installations in ships Part 350: Shipboard power cables General construction and test requirements Installations électriques à bord

More information

PERFORMANCE POLYMER SOLUTIONS

PERFORMANCE POLYMER SOLUTIONS PERFORMANCE POLYMER SOLUTIONS THERMODAN PEXIDAN HF PEXIDAN Advanced LSZH Thermoplastic Compounds Advanced LSZH Cross-Linkable Compounds XLPE Cross-Linkable Compounds Moisture Cure Technology SACO AEI

More information

The Quality Connection. BETAflam safety cables for highest demands

The Quality Connection. BETAflam safety cables for highest demands The Quality Connection BETAflam safety cables for highest demands 2 For solutions that will still be standard tomorrow. BETAflam safety cables Thanks to their proven quality, BETAflam safety cables are

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61156-4 Edition 3.0 2009-05 Multicore and symmetrical pair/quad cables for digital communications Part 4: Riser cables Sectional specification INTERNATIONAL ELECTROTECHNICAL

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Presley House Presley Way Crownhill Milton Keynes MK8 0ES United Kingdom Contact: Jeremy Hodge Tel: +44 (0) 1908 267300 Fax: +44 (0) 1908

More information

FUMEGUARD TM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED LOW SMOKE HALOGEN FREE CABLES

FUMEGUARD TM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED LOW SMOKE HALOGEN FREE CABLES Cables Limited MADE IN IRELAND SINCE 1934 QUALITY APPROVED CABLES IDH CABLES LIMITED FUMEGUARD TM LOW SMOKE HALOGEN FREE CABLES The longest-running original range of low voltage, low smoke, halogen free

More information

Electrical test. Determining resistance of conductors by means of using DC four-wire connection measurement

Electrical test. Determining resistance of conductors by means of using DC four-wire connection measurement Nr. Material or Product Type of activity Internal reference number 1 Cables of rated voltage up to Electrical test Determining resistance of conductors by means of using DC four-wire connection measurement

More information

LV FIRE RESISTANT CABLES

LV FIRE RESISTANT CABLES LV FIRE RESISTANT CABLES CONTENTS 3 GENERAL INTRODUCTION LV FIRE RESISTANT CABLES TECHNICAL INFORMATION 4 9 12 24 26 GENERAL CABLE STRUCTURE ELECTRICAL CHARACTERISTICS CURRENT RATING VOLTAGE DROP SHORT

More information

C6 Premium. C6 Premium Copper Systems from Infinique is premium performing Class E / Category 6 Data Communication

C6 Premium. C6 Premium Copper Systems from Infinique is premium performing Class E / Category 6 Data Communication Stable and Reliable Data Communication Solutions from Infinique Infinique provides high quality end-to-end solutions for communication infrastructure that bring great value to its customers. We have achieved

More information

Brand Portable Power Cord & Control Cable Solutions

Brand Portable Power Cord & Control Cable Solutions Carol Brand Portable Power Cord & Control Cable Solutions for the Entertainment Market General Cable s Carol Brand portable power cord and control cable solutions are manufactured for use in the entertainment

More information

Caledonian. FIREFLIX ire Resistant Coaxial Cables

Caledonian. FIREFLIX ire Resistant Coaxial Cables Caledonian FIREFLIX ire Resistant Coaxial Cables table OF COntents Fire resistant Coaxial Cables Fire Resistant RG59 B/U coaxial cables...25 Fire Resistant RG6 A/U coaxial cables...28 Fire Resistant RG6

More information

Belden Infinity C-TC+ Cables for Extreme Flexing

Belden Infinity C-TC+ Cables for Extreme Flexing Product Bulletin PB 0 Belden Infinity Cables These highly flexible control, power, video and data cables handle the rigorous speeds and near-constant motion of C-track systems, robots, pick-and-place machines,

More information

Multipurpose Cables (indoor/outdoor), Multipurpose central tube cable (maxibundle) with glass yarn armouring A-DQ(BN)H 4-24

Multipurpose Cables (indoor/outdoor), Multipurpose central tube cable (maxibundle) with glass yarn armouring A-DQ(BN)H 4-24 Features and Benefits Laminated swelling glass yarns Improved rodent resistance and longitudinal water protection UV and microbe resistant Can be directly buried or installed in ducts Metal-free cable

More information

LSOH Flexible Cables

LSOH Flexible Cables LSOH Flexible Cables Low Voltage (300/500 V) 3182B, 3183B, 3184B Piresafe TM Flex Cable Approvals Key Applications > Supply leads for medium duty domestic and office appliances, lighting fittings and portable

More information

FIRE RESISTANT CABLES FP400

FIRE RESISTANT CABLES FP400 FIRE RESISTANT CABLES FP400 FIRE RESISTANT CABLES FP400 BS7846-F2 CABLE CHARACTERISTICS FP400 APPROVALS INSTALLATION Certificate No 077b Certificate No 517b > Prysmian FP400 is the original fire resistant

More information

MEDIUM VOLTAGE CABLES INSTRUMENTATION CABLES RUBBER CABLES FIRE RESISTANT CABLES

MEDIUM VOLTAGE CABLES INSTRUMENTATION CABLES RUBBER CABLES FIRE RESISTANT CABLES RUBBER CABLES FIRE RESISTANT CABLES INSTRUMENTATION CABLES MEDIUM VOLTAGE CABLES Halley Cables, established in 2006, is a dynamic company, specialized in power supply, which focuses on customers satisfaction.

More information

CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag

CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag STANDARD COLOR CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag TECHNICAL DATA SHEET Revision Number. 1 Last Edited 9. januar 2019 OTHER COLORS MATERIAL Flat band cross linked polyolefin. OPERATING

More information