SPECIAL ELECTRICAL AND OPTICAL CABLES

Size: px
Start display at page:

Download "SPECIAL ELECTRICAL AND OPTICAL CABLES"

Transcription

1

2 SPECIAL ELECTRICAL AND OPTICAL CABLES

3

4 INTRODUCTION The new high-speed trains and the sensible increase of the traffic, with congested lines, is the result of the latest development of the rail sector. As a result, the need for high safety standards for the rail transport has become more critical and drew the attention of the Transportation sector. In order to provide users with high standards and a reliable service, the industry has focused its efforts on the development of the signalling equipment, handling the exchange of information between the system and the moving vehicle. We engineer and manufacture copper and fiber optic cables for the entire range of the signalling systems adopted by both the mass transit and high-speed lines. Our different product lines meet system requirements of the whole Industry; our cables are specially designed for any specific application, being indoor/outdoor, aerial, directly buries or in-duct. We constantly focus our efforts on satisfying the transportation requirements in terms of construction, and stand out in the market for our expertise in the product engineering according with any specific requirement. Our production range includes a wide range of products suitable for: - Tunnel installation and indoor environments. This is achieved by our LZH non-propagating compounds which satisfy the severe international standards - Security Systems. Our Fire resistant cables guarantee a steady supply of the system, even in the event of a fire. - High mechanical stress. Our cables can withstand heavy loads and severe environmental conditions, such as Arctic temperatures and High Magnetic Interferences Our cables are the result of broad enthusiasm, constant research and deep expertise, always aiming at the full satisfaction of our customers, an endless improvement of the comfort and the safety in the rail transportation. PRODUCT LINES

5 TECNIKABEL is focused on constant product innovation to get competitive advantages with endless commitment to research and development. PRODUCTION Updated production Systems, stringent process procedures and expert operators reached the goal to carry out our production efficient and flexible. In years of activity, we produced more than 6. different types of cables. FINAL INSPECTIONS At the end of every production process each cable is checked in its electrical and physical performances for a complete compliance to customer specifications. LABORATORY TESTS We submit our cables to the most severe tests, simulating critical applications. In addition to the tests required by current norms, we invest on new special equipment for additional mechanical and electrical testing, heading to a steady increase of standard performance of our cables. MATERIALS RESEARCH AND DEVELOPMENT Our thirty year experience took us to carry on research of new materials in order to improve performances, costs and fulfill the standards required by our customers.

6 QUALITY SYSTEM Since 978, constant commitment to Quality has awarded Tecnikabel approval from American and European Authorities, complying with the most demanding international manufacturing and quality standards. ISO 9:8 95 TEKA 5

7 INDEX SCMT EUROBALISE - TRACKSIDE SUBSYSTEM CABLES... TK-SCMT-SST ENCODER BOA xx TK-SCMT-SST xx...6 TK-SCMT-SST xx TK-BOA EUROBALISE xx...8 TK-CDB AUDIOFREQUENCY MULTIPAIRS...9 TK-EUROBALISE TUNNEL MULTIPAIRS.9... TK-EUROBALISE MULTIPAIRS.9... TELECOMMUNICATION CABLES... 5 TK-TELEPHONE MULTIPAIRS TK-TRAIN DETECTION x...7 TK-CANCABLE xx...8 TK-UNBALANCED CURRENT SENSOR xx TK-TELEPHONE MULTIQUADS.7... TK-TELEPHONE MULTIQUADS.9/... TK-PZB INDUSI AUTOMATIC TRAIN CONTROL x TK-ARMOURED PZB INDUSI AUTOMATIC TRAIN CONTROL x SIGNALLING CABLES... 7 TK-H5 SIGNAL MULTICONDUCTORS - REDUCTION FACTOR...8 TK-H7 SIGNAL MULTICONDUCTORS - REDUCTION FACTOR... TK-H7 SIGNAL MULTIPAIRS - REDUCTION FACTOR... TK-CW SIGNAL MULTIQUADS - REDUCTION FACTOR... TK-9 SIGNAL...6 TK-ARMOURED 9 SIGNAL...8 TK-POINT MACHINE...5 OPTICAL CABLES... 5 TK-BCA FIBER OPTIC TRAIN DETECTION...5 TK-UT9X ARMOURED UNITUBE...56 TK-UTXD ARMOURED UNITUBE DOUBLE SHEATH...58 TK-MT9X ARMOURED MULTITUBE...6 TK-API AIRBAG PROTECTION...6 TK-MT6X ARMOURED MULTITUBE...66 TK-MTAS MULTITUBE ADSS

8 SYMBOLS ENVIRONMENTAL PROPERTIES FLAME RETARDANT SINGLE WIRE (EN/IEC 6--, EN 565--) FLAME RETARDANT BUNCHED WIRES (IEC 6-, EN , EN 559-, EN , EN 566-) ANTIBALLISTIC PROTECTION UV RESISTANT FIRE RESISTANCE (IEC 6, EN5, EN 56, BS687 CWZ) REDUCED EMISSION OF FUMES AND TOXIC GASES (IEC 675-; EN 567--/, EN 55 9.) ARCTIC CABLE INDOOR/OUTDOOR SMOKE DENSITY (EN/IEC 6-/) (EN 568-; EN 568-/) REDUCTION FACTOR LOW ACIDITY AND CORROSIVITY OF EVOLVED GASES (IEC 675-, EN 567--) CHEMICAL PROPERTIES WEATHERING TEST RESISTANCE (OUTDOOR) MUD RESISTANCE INDOOR MINERAL OIL RESISTANCE WATER RESISTANCE HYDROCARBONS RESISTANCE RODENT RESISTANCE PVC PVC VERSION HAZARDOUS AREA MECHANICAL PROPERTIES FLEXIBLE INSTALLATION MECHANICAL RESISTANCE FULLY DIELECTRIC REDUCED BENDING RADIUS DIRECT BURIAL WORK AT LOW TEMPERATURE 7

9

10 FIRE PERFORMANCES 9

11 IEC 6-- / EN 565: Fire propagation on a vertical single cable. The single cable is mounted vertically and flamed with a Bunsen burner. The flame must extinguish itself, at least 5 mm below the upper fixing clamp. Temperature of burner, duration and angle of flame application, are described in the reference standards. IEC 6- / EN 566 / EN : Fire propagation on a vertical cables bundle. A certain number of cable samples are fixed on a.5m long ladder, and flamed with an appropriate burner. The samples number, the duration of flame application, and the power/temperature of burner are described in the reference standards. After flame application, the visible area of fire damage must not exceed.5 m in height from the bottom of the burner. The volume of tested material define a differentiation in categories: A/FR Part - 7 l/m A Part - 7 l/m B Part -.5 l/m C Part -.5 l/m D Part -5.5 l/m IEC 6 / EN 5 / EN 56 : Fire test resistance. A sample of cable is horizontally applied supported by metal rings, or in U shape fixed on a fireproof wall. Through using a gas burner the cable It s maintained in flame contact for a certain time. The test and the temperature of burner are described in the reference standards. In U shape test, the fireproof wall is hit every five minutes by a mechanical shock, to simulate a potential collapse during the fire. The time of fire application, and the temperature of flame are described in the reference standards (typical 75 C or 8 C). During the test a current for continuity checking is passed through all conductors of the cable and the voltage must be maintained during the test duration.

12 IEC 6-/ / EN 568-/: Measurement of smoke density of cables burning under defined conditions. A few samples of cable are burnt in a cubic (xxm) chamber using a flammable liquid. The light transmittance of the resulting smoke is measured using an optical light detector. The test duration is about minutes, depending by the quantity and composition of the liquid fuel. At the end of the test the light transmittance of the smoke must be 6% minimum. IEC 675- / EN 567--/: Test on gases evolved during combustion of materials from cables - Determination of the halogen acid gas content. This standard covers the general aspects of potential hazard caused from corrosiveness of smoke and combustion gases. A small quantity of non-metallic material is heated in a tube, the resulting gases are tested for their halogen content. The flame temperature is 8 C ± C, with a test duration of ± 5 min in total. The halogen content of non-metallic materials must be less than.5% or 5 mg/g. IEC 675- / EN 567--: Test on gases evolved during combustion of materials from cables - Determination of acidity (by ph measurement) and conductivity. A small quantity of non-metallic material is burnt in a furnace, the ph and conductivity combustion gases dissolved in water are measured. The minimum ph value of the washing water must., and the maximum conductivity must be μs/mm.

13 Construction products regulation Regulation No. 5/ (Construction Products Regulation, or CPR) of the European Parliament and of the European Council is a regulation of 9 March that lays down harmonised conditions for the marketing of construction products and replaces Construction Products Directive (89/6/EEC). The EU regulation is designed to simplify and clarify the existing framework for the placing on the EU market of construction products. The main objective of the CPR is the removal of technical barriers to trade in order to guarantee the free movement of construction products within the common internal market due to differing product and test standards, approval processes and conformity documents in the various member states. After the transition period, which ended on July 7, the Construction Products Regulation governs cables intended to be incorporated in construction works (permanent installations) in both buildings and civil engineering. CPR Euroclasses are: Aca, Bca, Bca, Cca, Dca, Eca, Fca. Aca Bca Bca Cca Dca Eca Fca Furthermore, there are additional criteria establishing requirements on the amount of smoke produced, the fall of droplets and flamed particles during combustion, and acid content or toxicity of smoke produced. s = smoke production. With decreasing performance, varies from s to s. Furthermore, s classification can be classified as s, sa or sb on the basis of smoke opacity. d = flaming droplets. With decreasing performance, varies from d to d a = smoke acidity. With decreasing performance, varies from a to a The DoP (Declaration of Performance) is a document issued by the manufacturer in which all relevant information is recorded: the manufacturer, cable identification, evaluation system used, applicable standard, CPR certification body and performance of the product. We are committed to adopting Euroclasses, and their relevant DoP, to express the fire performance of our products for the different construction applications, even if incumbent operators specifications eventually conflict with the CPR Regulations.

14 scmt eurobalise - trackside subsystem cables The images are for illustrative purposes only

15 TK-SCMT-SSt encoder boa xx.9 CABLE SPECIFICATIONS Conductor Insulation Pair Total Assembling Armouring Solid bare copper,.9 mm Coloured Polyethylene Two conductors assembled to form a pair N pairs assembled together with eventual filler and tape Corrugated steel tape thermowelded to outer sheath Green flame retardant, low smoke and halogen-free compound or black Polyethylene PVC TECHNICAL DATA Operating temperature Minimum bending radius - C + 7 C xø FIRE PERFORMANCE Only for LSZH version Fire propagation Smoke density Halogen-free Fumes IEC 6-- IEC 6-- IEC 6-/ IEC 675-/ No corrosive and toxic fumes MAIN FEATURES Only for PE version Only for LSZH version Test voltage Characteristic to 5 KHz Mutual 8 Hz Capacitance unbalance Max to 5 KHz V DC x minute ± Ω 5 pf/m pf/5m db/km UV resistant Arctic cables Indoor/Outdoor Oil resistant PVC version

16 TK-SCMT-SSt encoder boa xx.9 Formation Conductor Resistance of C MAIN FEATURES Insulation C thickness Ø (n of pairs) (mm) (Ω/km) (GΩxkm) (mm) (mm) (kg/km) Nominal weight PE LSZH (kg/km)

17 TK-SCMT-SSt xx. CABLE SPECIFICATIONS Conductor Insulation Assembling Screen and moisture barrier Inner sheath Armouring Outer diameter Solid bare copper,. mm Coloured foam Polyolefin Two conductors assembled to form a pair with eventual filler and tape Aluminium/PE/tape thermowelded to inner sheath + drain wire Flame retardant, low smoke and halogen-free compound or Polyethylene Two steel tapes helically applied Green flame retardant, low smoke and halogen-free compound or black Polyethylene.8 mm TECHNICAL DATA Operating temperature Minimum bending radius - C + 7 C xø PVC FIRE PERFORMANCE Only for LSZH version Fire propagation Smoke density Halogen-free Fumes IEC 6-- IEC 6-- IEC 6-/ IEC 675-/ No corrosive and toxic fumes MAIN FEATURES Only for PE version Only for LSZH version Resistance of C Insulation C Test voltage Characteristic impedance Mutual 8 Hz Capacitance unbalance Max attenuation KHz. Ω/km GΩ x km V AC x minute Ω Ω 5 pf/m pf/km.9 db/km 5.5 db/km.6 μh/m.5 μh/m Nominal weight 85 kg/km kg/km 6 Filling compound UV resistant Arctic cables Indoor/Outdoor Reduction factor Oil resistant PVC version

18 TK-SCMT-SSt xx.6 CABLE SPECIFICATIONS Conductor Insulation Assembling Inner sheath Screen and moisture barrier Intermediate sheath Armouring Outer diameter Solid bare copper,.6 mm Coloured foam Polyolefin Two conductors assembled to form a pair with filler and tape Natural Polyethylene Aluminium/PE/tape thermowelded to intermediate sheath + drain wire Flame retardant, low smoke and halogen-free compound or Polyethylene Two steel tapes helically applied Black flame retardant, low smoke and halogen-free compound or black Polyethylene 6.5 mm TECHNICAL DATA Operating temperature Minimum bending radius - C + 7 C xø PVC FIRE PERFORMANCE Only for LSZH version Fire propagation Smoke density Halogen-free Fumes IEC 6-- IEC 6-- IEC 6-/ IEC 675-/ No corrosive and toxic fumes MAIN FEATURES Only for PE version Only for LSZH version Resistance of C Insulation C Test voltage Characteristic impedance Mutual 8 Hz Capacitance unbalance Max attenuation KHz 9. Ω/km GΩ x km V AC x minute Ω Ω 9 pf/m pf/km.7 db/km.8 db/km.65 μh/m.5 μh/m Nominal weight kg/km 6 kg/km Filling compound UV resistant Arctic cables Indoor/Outdoor Reduction factor Oil resistant PVC version 7

19 TK-boa EUROBALISE xx. CABLE SPECIFICATIONS Conductor Insulation Assembling Screen and moisture barrier Inner sheath Armouring Outer diameter Solid Bare Copper,. mm Coloured Polyethylene Two conductors assembled to form a pair with eventual filler and tape Aluminium/PE/tape thermowelded to inner sheath Flame retardant, low smoke and halogen-free compound or Polyethylene Corrugated steel tape thermowelded to outer sheath Green flame retardant, low smoke and halogen-free compound or black Polyethylene mm PVC TECHNICAL DATA Operating temperature Minimum bending radius - C + 7 C xø FIRE PERFORMANCE Only for LSZH version Fire propagation Smoke density Halogen-free Fumes IEC 6-- IEC 6-- IEC 6-/ IEC 675-/ No corrosive and toxic fumes MAIN FEATURES Resistance of C.5 Ω/km Only for PE version Only for LSZH version Insulation resistance Test C GΩ x km 5 V DC x minute Characteristic MHz 5 Ω Mutual 8 Hz pf/m Max KHz.7 db/km 7. db/km 9.5 db/km Nominal weight 6 kg/km kg/km Filling compound UV resistant Arctic cables Indoor/Outdoor Oil resistant PVC version 8

20 TK-CDB AUDIOFREQUENCY multipairs. CABLE SPECIFICATIONS Conductor Insulation Assembling Inner sheath Screen and moisture barrier Intermediate sheath Armouring Outer diameter Solid bare copper,. mm Solid Bare Copper,.6 mm (Service pair) Coloured Polyethylene One or two pairs + service pair assembled together Polyethylene Aluminium/PE/tape thermowelded to intermediate sheath Flame retardant, low smoke and halogen-free compound or Polyethylene Two steel tapes helically applied Green flame retardant, low smoke and halogen-free compound or black Polyethylene 7 mm ( pair) mm ( pairs) PVC TECHNICAL DATA Operating temperature Minimum bending radius - C + 7 C 6xØ FIRE PERFORMANCE Only for LSZH version Fire propagation Smoke density Halogen-free Fumes IEC 6-- IEC 6-- IEC 6-/ IEC 675-/ No corrosive and toxic fumes MAIN FEATURES Only for PE version Only for LSZH version Resistance of C Insulation C Test voltage Characteristic KHz Mutual 8 Hz Capacitance unbalance Max attenuation Nominal weight Reduction KHz. Ω/km 5 GΩ x km V DC x minute Ω 5 pf/m pf/5m.76 db/km.5 db/km 8 kg/km ( pair) 5 kg/km ( pairs) 7 kg/km ( pair) 58 kg/km ( pairs).8 Filling compound UV resistant Arctic cables Indoor/Outdoor Oil resistant PVC version 9

21 TK- eurobalise TUNNEL multipairs.9 CABLE SPECIFICATIONS Conductor Insulation Filling Pair Total Assembling Screen and moisture barrier Inner sheath Solid bare copper,.9 mm Coloured Polyethylene Waterblock yarn (dry core) conductors assembled to firm a pair N pairs assembled together with eventual filler and tape Aluminium/PE/tape thermowelded to outer sheath + drain wire Green flame retardant, low smoke and halogen-free compound Green flame retardant, low smoke and halogen-free compound TECHNICAL DATA Operating temperature Minimum bending radius - 5 C + 7 C xø FIRE PERFORMANCE Fire propagation Smoke density Halogen-free Fumes IEC 6-- IEC 6-- IEC 6-/ IEC 675-/ No corrosive and toxic fumes MAIN FEATURES Test voltage 5 V DC x minute Characteristic MHz Mutual 8 Hz Max 8.8 KHz 5 Ω 5 pf/m.7 db/km. db/km db/km UV resistant Arctic cables Indoor/Outdoor Oil resistant

22 TK- eurobalise TUNNEL multipairs.9 MAIN FEATURES Formation Conductor Resistance of C Insulation C thickness Ø (n of pairs) (mm) (Ω/km) (GΩxkm) (mm) (mm) Nominal weight LSZH (kg/km) 8 5

23 TK- eurobalise multipairs.9 PVC CABLE SPECIFICATIONS Conductor Insulation Filling Pair Total Assembling Screen and moisture barrier Inner sheath Armouring Solid bare copper,.9mm Coloured foam Polyethylene Petroleum jelly Two conductors assembled to form a pair N pairs assembled together with eventual filler and tape Aluminium/PE/tape thermowelded to inner sheath + drain wire Flame retardant, low smoke and halogen-free compound or Polyethylene Corrugated steel tape thermowelded to outer sheath Green flame retardant, low smoke and halogen-free compound of black Polyethylene TECHNICAL DATA Operating temperature Minimum bending radius - C + 7 C xø FIRE PERFORMANCE Only for LSZH version Fire propagation Smoke density Halogen-free Fumes IEC 6-- IEC 6-- IEC 6-/ IEC 675-/ No corrosive and toxic fumes MAIN FEATURES Test voltage 5 V DC x minute Only for PE version Only for LSZH version Characteristic MHz Mutual 8 Hz Max 8.8 KHz 5 Ω 5 pf/m.7 db/km. db/km db/km UV resistant Arctic cables Indoor/Outdoor Oil resistant PVC version

24 TK- eurobalise multipairs.9 Formation Conductor Resistance of C MAIN FEATURES Insulation C thickness Ø (n of pairs) (mm) (Ω/km) (GΩxkm) (mm) (mm) (kg/km) Nominal weight PE LSZH (kg/km) 9 5

25 NOTE

26 telecommunication cables

27 TK-Telephone multipairs.7 CABLE SPECIFICATIONS Conductor Insulation Pair Total Assembling Screen Solid bare copper,.7 mm Coloured Polyethylene conductors assembled to form a pair pairs assembled together with eventual filler and tape Aluminium tape + drain wire Armouring Outer diameter Corrugated steel tape thermowelded to outer sheath Green flame retardant, low smoke and halogen-free or black Polyethylene.5 mm PVC TECHNICAL DATA Operating temperature Minimum bending radius - C + 7 C 5xØ FIRE PERFORMANCE Only for LSZH version Fire propagation Smoke density Halogen-free Fumes IEC 6-- IEC 6-- IEC 6-/ IEC 675-/ No corrosive and toxic fumes MAIN FEATURES Only for PE version Only for LSZH version Resistance of C Insulation C Test voltage Mutual 8 Hz Capacitance unbalance Nominal weight 7 Ω/km 5 GΩ x km V AC x minute 5 pf/m 6 pf/5m 5 kg/km 8 kg/km UV resistant Arctic cables Indoor/Outdoor Oil resistant PVC version 6

28 TK-train detection x. CABLE SPECIFICATIONS Conductor Insulation Assembling Screen Inner sheath Armouring Outer diameter Solid bare copper,. mm Coloured foam Polyolefin conductors assembled together to form a star quad Corrugated copper tape Flame retardant, low smoke and halogen-free compound or Polyethylene Two steel tapes helically applied Green flame retardant, low smoke and halogen-free compound or black Polyethylene 7.5 mm PVC TECHNICAL DATA FIRE PERFORMANCE Only for LSZH version Operating temperature Minimum bending radius Fire propagation Smoke density Halogen-free Fumes - C + 7 C xø IEC 6-- IEC 6-- IEC 6-/ IEC 675-/ No corrosive and toxic fumes MAIN FEATURES Resistance of C. Ω/km Only for PE version Only for LSZH version Insulation C Test voltage Mutual 8 Hz Capacitance unbalance Max attenuation Nominal weight Reduction 5 5 KHz GΩ x km 5 V DC x minute pf/m 5 pf/5m.6 db/km.85 db/km 5 kg/km 6 kg/km. Filling compound UV resistant Arctic cables Indoor/Outdoor Oil resistant PVC version 7

29 TK-CANCABLE xx. PVC CABLE SPECIFICATIONS TECHNICAL DATA Conductor Insulation Conductor communication core Insulation communication core Assembling Operating temperature Minimum bending radius Stranded bare copper,. mm Coloured foam Polyolefin Stranded bare copper,.5 mm Coloured Polyethylene Two pairs + communication core assembled together + drain wire Screen Aluminium or Aluminium/Polyester + drain wire Armouring Corrugated steel tape thermowelded to outer sheath Black flame retardant, low smoke and halogen-free or Polyethylene Outer diameter 6 mm - C + 7 C xø FIRE PERFORMANCE Only for LSZH version Fire propagation Smoke density Halogen-free Fumes IEC 6-- IEC 6-- IEC 6-/ IEC 675-/ No corrosive and toxic fumes MAIN FEATURES Resistance of C. Ω/km Resistance unbalance % Only for PE version Only for LSZH version Insulation C Test voltage Mutual 8 Hz Max 6 KHz Nominal weight 5 MΩ x km V DC x minute 75 pf/m.88 db/km 7 kg/km kg/km Filling compound UV resistant Arctic cables Indoor/Outdoor Oil resistant PVC version 8

30 TK-unbalanced current sensor xx.9 PVC CABLE SPECIFICATIONS Conductor Insulation Pair Pair screen Total Assembling Screen and moisture barrier Inner sheath Armouring Outer diameter Solid bare copper,.9 mm Coloured Polyethylene conductors assembled to form a pair Aluminium/PE tape + drain wire pairs assembled together with eventual filler and tape Aluminium/PE tape thermowelded to inner sheath Flame retardant, low smoke and halogen-free or Polyethylene Steel wire armour (SWA) Green flame retardant, low smoke and halogen-free or black Polyethylene 9 mm TECHNICAL DATA Operating temperature Minimum bending radius - C + 7 C xø FIRE PERFORMANCE Only for LSZH version Fire propagation Smoke density Halogen-free Fumes IEC 6-- IEC 6-- IEC 6-/ IEC 675-/ No corrosive and toxic fumes MAIN FEATURES Only for PE version Only for LSZH version Resistance of C Insulation C Test voltage Characteristic KHz Mutual 8 Hz Max KHz 8. Ω/km GΩ x km V AC x minute Ω 56 pf/m.8 db/km Nominal 8 Hz 7 kg/km 5 kg/km Arctic cables Indoor/Outdoor Oil resistant PVC version 9

31 TK- telephone multiquads.7 CABLE SPECIFICATIONS Conductor Insulation Quad Total Assembling Armouring Solid bare copper,.7 mm Coloured Polyethylene conductors assembled together to form a star quad + service quad N star quads assembled with eventual filler and tape Aluminium welded, thickness.mm Green flame retardant, low smoke and halogen-free compound or black Polyethylene PVC TECHNICAL DATA Operating temperature Minimum bending radius - C + 7 C xø FIRE PERFORMANCE Only for LSZH version Fire propagation Smoke density Halogen-free Fumes IEC 6-- IEC 6-- IEC 6-/ IEC 675-/ No corrosive and toxic fumes MAIN FEATURES Test voltage Mutual 8 Hz Capacitance unbalance V AC x minute 8.5 pf/m 8 pf/5m Only for PE version Only for LSZH version UV resistant Arctic cables Indoor/Outdoor Oil resistant PVC version

32 TK- telephone multiquads.7 MAIN FEATURES Formation (n of pairs) 5 Conductor Resistance of C Insulation C thickness Ø (mm) (Ω/km) (GΩxkm) (mm) (mm) (kg/km) Nominal weight PE LSZH (kg/km)

33 TK- telephone multiquads.9/ CABLE SPECIFICATIONS Conductor Insulation Quad Total Assembling Armouring Solid bare copper,.9mm/mm Coloured foam Polyolefin conductors assembled together to form a star quad + service quad N star quads assembled with eventual filler and tape Aluminium welded, thickness.mm Green flame retardant, low smoke and halogen-free compound or black Polyethylene PVC TECHNICAL DATA Operating temperature Minimum bending radius - C + 7 C xø FIRE PERFORMANCE Only for LSZH version Fire propagation Smoke density Halogen-free Fumes IEC 6-- IEC 6-- IEC 6-/ IEC 675-/ No corrosive and toxic fumes MAIN FEATURES Test voltage Mutual 8 Hz Capacitance unbalance V AC x minute pf/m (.9 mm) 8.5 pf/m ( mm) 8 pf/5m Only for PE version Only for LSZH version UV resistant Arctic cables Indoor/Outdoor Oil resistant PVC version

34 TK- telephone multiquads.9/ MAIN FEATURES Formation (n of pairs) 5 5 Conductor Resistance of C Insulation C thickness Ø (mm) (Ω/km) (GΩxkm) (mm) (mm) (kg/km) Nominal weight PE LSZH (kg/km)

35 TK-PZB indusi Automatic train control x.75 CABLE SPECIFICATIONS Conductor Insulation Assembling Inner sheath Screen and moisture barrier Outer diameter Stranded bare copper,.75 mm Coloured Polyethylene conductors assembled together to form a star quad with eventual filler and tape Flame retardant, low smoke and halogen-free or Polyethylene Aluminium/PE/tape thermowelded to outer sheath Green flame retardant, low smoke and halogen-free or black Polyethylene.5 mm PVC TECHNICAL DATA Operating temperature Minimum bending radius - C + 8 C xø Only for PE version Only for LSZH version FIRE PERFORMANCE Only for LSZH version Fire propagation Smoke density Halogen-free Fumes IEC 6-- IEC 6-- IEC 6-/ IEC 675-/ No corrosive and toxic fumes MAIN FEATURES Resistance of C Insulation C Test voltage Mutual 8 Hz 6 Ω/km 5 GΩ x km 5 V AC x minute 8 pf/m Nominal weight 8 kg/km 5 kg/km UV resistant Arctic cables Indoor/Outdoor Oil Resistant PVC version

36 TK-armoured PZB INDUSI Automatic train control x.8 CABLE SPECIFICATIONS Conductor Insulation Assembling Screen and moisture barrier Inner sheath Armouring Outer diameter Solid bare copper,.8 mm Coloured Foam Polyolefin conductors assembled together to form a star quad with eventual filler and tape Aluminium/PE/tape thermowelded to inner sheath Flame retardant, low smoke and halogen-free or Polyethylene Two steel tapes helically applied Green flame retardant, low smoke and halogen-free or black Polyethylene 5 mm PVC TECHNICAL DATA Operating temperature Minimum bending radius - C + 8 C xø FIRE PERFORMANCE Only for LSZH version Fire propagation Smoke density Halogen-free Fumes IEC 6-- IEC 6-- IEC 6-/ IEC 675-/ No corrosive and toxic fumes MAIN FEATURES Resistance of C 8 Ω/km Insulation C Test voltage Mutual 8 Hz 5 GΩ x km 5 V AC x minute pf/m Only for PE version Only for LSZH version Nominal weight 5 kg/km kg/km UV resistant Arctic cables Indoor/Outdoor Reduction factor Oil resistant PVC version 5

37 NOTE

38 signalling cables

39 TK- h5 signal multiconductors - reduction factor CABLE SPECIFICATIONS Conductor Insulation Assembling Screen and moisture barrier Inner sheath Armouring Solid bare copper Black numbered Polyethylene N conductors assembled together with eventual filler and tape Aluminium/PE/tape thermowelded to inner sheath Flame retardant, low smoke and halogen-free or Polyethylene Two steel tapes helically applied Green flame retardant, low smoke and halogen-free or black Polyethylene TECHNICAL DATA Operating temperature Minimum bending radius - C + 7 C xø PVC FIRE PERFORMANCE Only for LSZH version Fire propagation Smoke density Halogen-free Fumes IEC 6-- IEC 6-- IEC 6-/ IEC 675-/ No corrosive and toxic fumes MAIN FEATURES Test voltage 5 V DC x minute Mutual 8 Hz Reduction Hz 65 pf/m. Only for PE version Only for LSZH version Filling compound UV resistant Arctic cables Indoor/Outdoor Oil resistant PVC version 8

40 TK- h5 signal multiconductors - reduction factor Formation Conductor Resistance of C MAIN FEATURES Insulation C thickness Ø (n of conductors) (mm) (Ω/km) (GΩxkm) (mm) (mm) (kg/km) Nominal weight PE LSZH (kg/km)

41 TK- h7 signal multiconductors - reduction factor CABLE SPECIFICATIONS Conductor Insulation Assembling Screen Inner sheath Armouring Solid bare copper,.9mm/.mm Black numbered Polyethylene N conductors assembled with eventual filler and tape Corrugated copper tape Flame retardant, low smoke and halogen-free or Polyethylene Two steel tapes helically applied Green flame retardant, low smoke and halogen-free or black Polyethylene PVC TECHNICAL DATA FIRE PERFORMANCE Only for LSZH version Operating temperature Minimum bending radius Fire propagation Smoke density Halogen-free Fumes - C + 7 C xø IEC 6-- IEC 6-- IEC 6-/ IEC 675-/ No corrosive and toxic fumes MAIN FEATURES Test voltage 5 V DC x minute Mutual 8 Hz Max attenuation Reduction Hz 5 pf/m.7 db/km (.9 mm).6 db/km (.9 mm).6 db/km (. mm).85 db/km (. mm). Only for PE version Only for LSZH version UV resistant Arctic cables Indoor/Outdoor Oil resistant PVC version

42 TK- h7 signal multiconductors - reduction factor MAIN FEATURES Formation (n of conductors) Conductor Resistance of C Insulation C thickness Ø (mm) (Ω/km) (GΩxkm) (mm) (mm) (kg/km) Nominal weight PE LSZH (kg/km)

43 TK- h7 signal multipairs - reduction factor CABLE SPECIFICATIONS Conductor Insulation Pair Total assembling Inner sheath Screen Intermediate sheath Armouring Solid bare copper Coloured Polyethylene conductors assembled together to form a pair N pairs assembled with eventual filler and tape Flame retardant, low smoke and halogen-free or Polyethylene Corrugated copper tape Flame retardant, low smoke and halogen-free or Polyethylene Two steel tapes helically applied Green flame retardant, low smoke and halogen-free or black Polyethylene PVC TECHNICAL DATA Operating temperature Minimum bending radius - C + 7 C xø FIRE PERFORMANCE Only for LSZH version Fire propagation Smoke density Halogen-free Fumes IEC 6-- IEC 6-- IEC 6-/ IEC 675-/ No corrosive and toxic fumes MAIN FEATURES Only for PE version Only for LSZH version Test voltage Mutual 8 Hz Capacitance unbalance Max 5 KHz Characteristic 5 KHz Reduction - 5 Hz 5 V DC x minute 55 pf/m 65 pf/5m.5 db/km Ω. Filling compound UV resistant Arctic cables Indoor/Outdoor Oil resistant PVC version

44 TK- h7 signal multipairs - reduction factor Formation Conductor section Resistance of C MAIN FEATURES Insulation C thickness Ø (n of pairs) (mm ) (Ω/km) (GΩxkm) (mm) (mm) (kg/km) Nominal weight PE LSZH (kg/km)

45 TK- cw signal multiquads - reduction factor CABLE SPECIFICATIONS Conductor Insulation Quad Total assembling Screen and moisture barrier Inner sheath Concentric screen Armouring Solid bare copper Coloured Polyethylene conductors assembled together to form a star quad N star quads assembled together with eventual filler and tape Aluminium/PE/tape thermowelded to inner sheath Flame retardant, low smoke and halogen-free or Polyethylene One solid copper layer Two steel tapes helically applied Green flame retardant, low smoke and halogen-free or black Polyethylene PVC TECHNICAL DATA Operating temperature Minimum bending radius - C + 7 C xø FIRE PERFORMANCE Only for LSZH version Fire propagation Smoke density Halogen-free Fumes IEC 6-- IEC 6-- IEC 6-/ IEC 675-/ No corrosive and toxic fumes MAIN FEATURES Only for PE version Only for LSZH version Test voltage Mutual 8 Hz Capacitance unbalance Max 9 KHz Reduction Hz Filling compound UV resistant Arctic cables Indoor/Outdoor Oil resistant PVC version 5 V AC x minute 5 pf/m 65 pf/5m. db/km (.9 mm).6 db/km (. mm).

46 TK- cw signal multiquads - reduction factor Formation Conductor Resistance of C MAIN FEATURES Insulation C thickness Ø (n of quads) (mm) (Ω/km) (GΩxkm) (mm) (mm) (kg/km) Nominal weight PE LSZH (kg/km)

47 TK- 9 signal CABLE SPECIFICATIONS Conductor Insulation Assembling Inner sheath Solid tinned copper, section from to 6 mm Stranded copper, section from to 5 mm Extra-flexible copper, section.5 mm Coloured type crosslinked LSZH compound N conductors assembled with eventual filler and tape Type crosslinked LSZH Black crosslinked flame retardant, low smoke and halogen-free compound or black Polyethylene TECHNICAL DATA Operating temperature Minimum bending radius - C + 7 C 5xØ PVC FIRE PERFORMANCE Only for LSZH version Fire propagation Smoke density Halogen-free Fumes IEC 6-- IEC 6-- IEC 6-/ IEC 675-/ No corrosive and toxic fumes Only for PE version Only for LSZH version Filling compound UV resistant Arctic cables Indoor/Outdoor Oil resistant PVC version 6

48 TK- 9 signal MAIN FEATURES Formation (n of conductors) Conductor section Resistance of C Insulation C thickness Ø (mm ) (Ω/km) (MΩxkm) (mm) (mm) (kg/km) Nominal weight PE LSZH (kg/km)

49 TK- armoured 9 signal CABLE SPECIFICATIONS Conductor Insulation Assembling Inner sheath Intermediate sheath Armouring Solid tinned copper, section from to 6 mm Stranded copper, section from to 5 mm Extra-flexible copper, section.5 mm Coloured type crosslinked LSZH compound N conductors assembled with eventual filler and tape Type crosslinked LSZH compound Type crosslinked LSZH compound Two steel tapes helically applied Black flame retardant, low smoke and halogen-free compound or black polyethylene TECHNICAL DATA Operating temperature Minimum bending radius - C + 7 C xø PVC FIRE PERFORMANCE Only for LSZH version Fire propagation Smoke density Halogen-free Fumes IEC 6-- IEC 6-- IEC 6-/ IEC 675-/ No corrosive and toxic fumes Filling compound UV resistant Arctic cables Indoor/Outdoor Reduction factor Oil resistant PVC version Only for PE version Only for LSZH version 8

50 TK- armoured 9 signal MAIN FEATURES Formation (n of conductors) Conductor Resistance of C Insulation C thickness Ø (mm) (Ω/km) (MΩxkm) (mm) (mm) (kg/km) Nominal weight PE LSZH (kg/km)

51 TK- point machine CABLE SPECIFICATIONS Conductor Insulation Assembling Screen Inner sheath Armouring Solid bare copper Black numbered Polyethylene 5 conductors assembled with eventual filler and tape Corrugated copper tape Flame retardant, low smoke and halogen-free or Polyethylene Two steel tapes helically applied Green flame retardant, low smoke and halogen-free or black Polyethylene PVC TECHNICAL DATA Operating temperature Minimum bending radius - C + 7 C xø FIRE PERFORMANCE Only for LSZH version Fire propagation Smoke density Halogen-free Fumes IEC 6-- IEC 6-- IEC 6-/ IEC 675-/ No corrosive and toxic fumes MAIN FEATURES Test voltage 5 V AC x 5 minute Mutual Hz 5 pf/m Max KHz. db/km (.5 mm KHz.8 db/km (.5 mm KHz. db/km ( mm KHz.78 db/km ( mm KHz. db/km (6 mm KHz.78 db/km (6 mm ) Reduction 5 Hz. Only for PE version Only for LSZH version Arctic cables Indoor/Outdoor Reduction factor Oil resistant PVC version 5

52 TK- point machine MAIN FEATURES Formation (n of conductors) Conductor section Resistance of C Insulation C thickness Ø (mm ) (Ω/km) (GΩxkm) (mm) (mm) (kg/km) Nominal weight PE LSZH (kg/km) 8 5

53 NOTE

54 OPTICAL cables

55 TK-BCA fiber optic train detection CABLE SPECIFICATIONS Fiber structure Tight colour code Assembling Protection Inner sheath Armouring Tight buffer 9 μm Semitight buffer 9 μm See table C fibers Aramidic yarns Flame retardant, low smoke and halogen-free Corrugated steel tape thermowelded to outer sheath Flame retardant, low smoke and halogen-free All cables are available with all type of fibers. TECHNICAL DATA Operating temperature Minimum bending radius - C + 8 C xø FIRE PERFORMANCE Fire propagation Smoke density Halogen-free Fumes IEC 6-- IEC 6-- IEC 6-/ IEC 675-/ No corrosive and toxic fumes Water resistant Polyethylene sheath for direct buried UV resistant Arctic cables Indoor/Outdoor Oil resistance 5

56 TK-BCA fiber optic train detection MAIN FEATURES No. of fiber 8 Nominal Nominal weight Max pulling force Max crush Impact (mm) (kg/km) (N) (N/dm) (J)

57 TK- ut9x armoured unitube CABLE SPECIFICATIONS Fiber structure Fiber colour code Loose tube colour Assembling Protection Armouring Jelly filled loose tube See table A Natural fibers With or without Aramidic/Glass yarns Corrugated steel tape thermowelded to outer sheath Flame retardant, low smoke and halogen-free or Polyethylene All cables are available with all type of fibers. TECHNICAL DATA Operating temperature Minimum bending radius - C + 8 C xø FIRE PERFORMANCE Only for LSZH version Fire propagation Smoke density Halogen-free Fumes IEC 6-- IEC 6-- IEC 6-/ IEC 675-/ No corrosive and toxic fumes Fire resistant Water resistant UV resistant Arctic cables Indoor/Outdoor Oil resistance Only for PE version Only for LSZH version 56

58 TK- ut9x armoured unitube MAIN FEATURES CST + LSZH SHEATH No. of fiber Loose Cable Max pulling Nominal weight Max crush Impact force (mm) (mm) (kg/km) (N) (N/dm) (J) MAIN FEATURES CST + ARAMIDIC YARNS + LSZH SHEATH No. of fiber Loose Cable Max pulling Nominal weight Max crush Impact force (mm) (mm) (kg/km) (N) (N/dm) (J) MAIN FEATURES CST + GLASS YARNS + LSZH SHEATH No. of fiber Loose Cable Max pulling Nominal weight Max crush Impact force (mm) (mm) (kg/km) (N) (N/dm) (J).5 5 MAIN FEATURES CST + PE SHEATH No. of fiber Loose Cable Max pulling Nominal weight Max crush Impact force (mm) (mm) (kg/km) (N) (N/dm) (J) MAIN FEATURES CST + ARAMIDIC YARNS + PE SHEATH No. of fiber Loose Cable Max pulling Nominal weight Max crush Impact force (mm) (mm) (kg/km) (N) (N/dm) (J) MAIN FEATURES CST + GLASS YARNS + PE SHEATH No. of fiber Loose Cable Max pulling Nominal weight Max crush Impact force (mm) (mm) (kg/km) (N) (N/dm) (J)

59 TK- utxd armoured unitube Double sheath CABLE SPECIFICATIONS Fiber structure Fiber colour code Loose tube colour Assembling Strain relief Inner sheath Armouring Jelly filled loose tube See table A Natural fibers Aramidic/Glass yarns Flame retardant, low smoke and halogen-free or Polyethylene Galvanized steel wire braid or corrugated and thermowelded steel tape Flame retardant, low smoke and halogen-free or Polyethylene All cables are available with all type of fibers. TECHNICAL DATA Operating temperature Minimum bending radius - C + 8 C xø FIRE PERFORMANCE Only for LSZH version Fire propagation Smoke density Halogen-free Fumes IEC 6-- IEC 6-- IEC 6-/ IEC 675-/ No corrosive and toxic fumes Fire resistant Water resistant UV resistant Arctic cables Indoor/Outdoor Oil resistance Only for PE version Only for LSZH version 58

60 TK- utxd armoured unitube Double sheath MAIN FEATURES LSZH + GSWB + LSZH SHEATH No. of fiber Loose (mm).8.5 Cable Max pulling Nominal weight Max crush Impact force (mm) (kg/km) (N) (N/dm) (J) MAIN FEATURES PE + GSWB + PE SHEATH No. of fiber Loose (mm).8.5 Cable Max pulling Nominal weight Max crush Impact force (mm) (kg/km) (N) (N/dm) (J) MAIN FEATURES LSZH + CST + LSZH SHEATH No. of fiber Loose (mm).8.5 Cable Max pulling Nominal weight Max crush Impact force (mm) (kg/km) (N) (N/dm) (J) MAIN FEATURES PE + CST + PE SHEATH No. of fiber Loose (mm).8.5 Cable Max pulling Nominal weight Max crush Impact force (mm) (kg/km) (N) (N/dm) (J)

61 TK- Mt9x armoured multitube CABLE SPECIFICATIONS Fiber structure Fiber colour code Loose tube colour Assembling Central element Protection Armouring Jelly filled loose tube See table A See table B 6 loose tubes/fillers 88 fibers Fiber reinforced polymer With or without Aramidic/Glass yarns Corrugated steel tape thermowelded to outer sheath Flame retardant, low smoke and halogen-free or Polyethylene All cables are available with all type of fibers. TECHNICAL DATA Operating temperature Minimum bending radius - C + 8 C xø FIRE PERFORMANCE Only for LSZH version Fire propagation Smoke density Halogen-free Fumes IEC 6-- IEC 6-- IEC 6-/ IEC 675-/ No corrosive and toxic fumes Fire resistant Water resistant UV resistant Arctic cables Indoor/Outdoor Oil resistance Only for PE version Only for LSZH version 6

62 TK- Mt9x armoured multitube MAIN FEATURES CST + LSZH SHEATH No. of fiber Loose No. loose No. filler Cable Nominal weight Max pulling force Max crush Impact (mm) (mm) (kg/km) (N) (N/dm) (J) MAIN FEATURES ARAMIDIC + CST + LSZH SHEATH No. of fiber Loose No. loose No. filler Cable Nominal weight Max pulling force Max crush Impact (mm) (mm) (kg/km) (N) (N/dm) (J)

63 TK- Mt9x armoured multitube MAIN FEATURES GLASS YARNS + CST + LSZH SHEAT No. of fiber Loose No. loose No. filler Cable Nominal weight Max pulling force Max crush Impact (mm) (mm) (kg/km) (N) (N/dm) (J) MAIN FEATURES CST + PE SHEATH No. of fiber Loose No. loose No. filler Cable Nominal weight Max pulling force Max crush Impact (mm) (mm) (kg/km) (N) (N/dm) (J)

64 TK- Mt9x armoured multitube MAIN FEATURES ARAMIDIC + CST + PE SHEATH No. of fiber Loose No. loose No. filler Cable Nominal weight Max pulling force Max crush Impact (mm) (mm) (kg/km) (N) (N/dm) (J) MAIN FEATURES GLASS YARNS + CST + PE SHEATH No. of fiber Loose No. loose No. filler Cable Nominal weight Max pulling force Max crush Impact (mm) (mm) (kg/km) (N) (N/dm) (J)

65 TK- api airbag protection CABLE SPECIFICATIONS TECHNICAL DATA Fiber structure Fiber colour code Jelly filled loose tube See table A Loose tube color See table B Assembling 8 loose tubes/fillers 6 96 fibers Central element Fiber reinforced polymer Inner sheath Flame retardant, low smoke and halogen-free or Polyethylene Mechanical protection Dielectric layer Armouring Anti rodent glass protection Flame retardant, low smoke and halogen-free or Polyethylene All cables are available with all type of fibers. Operating temperature Minimum bending radius - C + 8 C 5xØ FIRE PERFORMANCE Only for LSZH version Fire propagation Smoke density Halogen-free Fumes IEC 6-- IEC 6-- IEC 6-/ IEC 675-/ No corrosive and toxic fumes Fire resistant UV resistant Arctic cables Indoor/Outdoor Oil resistance Only for PE version Only for LSZH version 6

66 TK- api airbag protection MAIN FEATURES LSZH + AIRBAG + GLASS TAPE AND YARNS + LSZH SHEATH No. of fiber Loose No. loose No. filler Cable Nominal weight Max pulling force Max crush Impact (mm) (mm) (kg/km) (N) (N/dm) (J) MAIN FEATURES PE + AIRBAG + GLASS TAPE AND YARNS + PE SHEATH No. of fiber Loose No. loose No. filler Cable Nominal weight Max pulling force Max crush Impact (mm) (mm) (kg/km) (N) (N/dm) (J)

67 TK- mt6x armoured multitube CABLE SPECIFICATIONS Fiber structure Fiber colour code Jelly filled loose tube See table A Loose tube color See table B Assembling 8 loose tubes/fillers 6 96 fibers Central element Fiber reinforced polymer Inner sheath Flame retardant, low smoke and halogen-free or Polyethylene Strain relief Aramidic layer Armouring Welded and corrugated steel tape (H6) Anticorrosion protection Bituminous/Jelly layer Flame retardant, low smoke and halogen-free or Polyethylene All cables are available with all type of fibers. TECHNICAL DATA Operating temperature Minimum bending radius - C + 8 C 5xØ FIRE PERFORMANCE Only for LSZH version Fire propagation Smoke density Halogen-free Fumes IEC 6-- IEC 6-- IEC 6-/ IEC 675-/ No corrosive and toxic fumes Fire resistant UV resistant Arctic cables Indoor/Outdoor Oil resistance Only for PE version Only for LSZH version 66

68 TK- mt6x armoured multitube MAIN FEATURES LSZH + ARAMIDIC YARNS + H6 + LSZH SHEATH No. of fiber Loose No. loose No. filler Cable Nominal weight Max pulling force Max crush Impact (mm) (mm) (kg/km) (N) (N/dm) (J) MAIN FEATURES PE + ARAMIDIC YARNS + H6 + PE SHEATH No. of fiber Loose No. loose No. filler Cable Nominal weight Max pulling force Max crush Impact (mm) (mm) (kg/km) (N) (N/dm) (J)

69 TK- Mtas multitube adss CABLE SPECIFICATIONS Fiber structure Fiber colour code Loose tube color Assembling Central element Inner sheath *Antiballistic protection Strain relief Jelly filled loose tube See table A See table B 6 loose tubes/fillers 88 fibers Fiber reinforced polymer Flame retardant, low smoke and halogen-free or Polyethylene Aramidic tapes or glass flats Aramidic layer Flame retardant, low smoke and halogen-free or Polyethylene * On request. All cables are available with all type of fibers. TECHNICAL DATA Operating temperature Minimum bending radius - C + 8 C 5xØ FIRE PERFORMANCE Only for LSZH version Fire propagation Smoke density Halogen-free Fumes IEC 6-- IEC 6-- IEC 6-/ IEC 675-/ No corrosive and toxic fumes Only for PE version Only for LSZH version Fire resistant Water resistant UV resistant Arctic cables Indoor/Outdoor Oil resistance 68

70 TK- Mtas multitube adss MAIN FEATURES LSZH + ARAMIDIC YARNS + LSZH SHEATH No. of fiber Loose No. loose No. filler Cable Nominal weight Max pulling force Max crush Impact (mm) (mm) (kg/km) (N) (N/dm) (J) MAIN FEATURES LSZH +ARAMIDIC YARNS AND TAPES + LSZH SHEATH No. of fiber Loose No. loose No. filler Cable Nominal weight Max pulling force Max crush Impact (mm) (mm) (kg/km) (N) (N/dm) (J)

71 TK- Mtas multitube adss MAIN FEATURES LSZH + ARAMIDIC YARNS + GLASS FLAT + LSZH SHEATH No. of fiber Loose No. loose No. filler Cable Nominal weight Max pulling force Max crush Impact (mm) (mm) (kg/km) (N) (N/dm) (J) MAIN FEATURES PE + ARAMIDIC YARNS + PE SHEATH No. of fiber Loose No. loose No. filler Cable Nominal weight Max pulling force Max crush Impact (mm) (mm) (kg/km) (N) (N/dm) (J)

72 TK- Mtas multitube adss MAIN FEATURES PE + ARAMIDIC YARNS AND TAPES + PE SHEATH No. of fiber Loose No. loose No. filler Cable Nominal weight Max pulling force Max crush Impact (mm) (mm) (kg/km) (N) (N/dm) (J) MAIN FEATURES PE +ARAMIDIC YARNS + GLASS FLAT + PE SHEATH No. of fiber Loose No. loose No. filler Cable Nominal weight Max pulling force Max crush Impact (mm) (mm) (kg/km) (N) (N/dm) (J)

73 FIBER CHARACTERISTICS SINGLEMODE FIBER PROPERTIES Mode Field nm 9, ±, μm 9, ±, μm 8,6 ±, μm 8,8 ±, μm Mode Field 55 nm, ±,5 μm, ±,5 μm 9,8 ±,5 μm 9,6 ±, μm Cladding diameter 5, ±,7 μm 5, ±,7 μm 5, ±,7 μm 5, ±,7 μm 5, ±,7 μm Coating diameter ± 7 μm ± 7 μm ± 7 μm ± μm ± 7 μm Cladding non-circularity Core/cladding concentricity error Coating/cladding concentricity error SM-LWP ITU-T G.65.D SM ITU-T G.657.A SM ITU-T G.657.A SM µm ITU-T G.657.A SM NZD ITU-T G.655.D Zero dispersion wavelength ( o) - nm - nm - nm - nm Dispersion slope ( o) Chromatic 85 nm ps/(nm *km) ps/(nm *km) ps/(nm *km) ps/(nm *km) * km) * km) Chromatic 55 nm *km) *km) Chromatic 65 nm *km) *km) Chromatic nm Chromatic nm PMD Individual 55 nm nm 8nm 55 nm 65 nm Attenuation with bending Mandrel Radius 5mm@55 turns Mandrel Radius 5mm@65 turns Mandrel Radius mm@55 turns Mandrel Radius mm@65 turns Mandrel Radius 7,5mm@55 turns Mandrel Radius 7,5mm@65 turns MULTIMODE FIBER PROPERTIES Proof test, -6, ps/(nm*km),5 to, ps/(nm*km) MULTIMODE FIBER PROPERTIES MM6,5 OM MM5 M MM5 OM MM5 OM 7 Core diameter 6,5 ±,5 μm 5 ±,5 μm 5 ±,5 μm 5 ±,5 μm Core non-circularity Cladding diameter 5, ±, μm 5, ±, μm 5, ±, μm 5, ±, μm Coating diameter ± 5 μm ± 5 μm ± 5 μm ± 5 μm Cladding non-circularity Core/cladding concentricity error Coating/cladding concentricity error Numerical Aperture,75 ±,5, ±,5, ±,5, ±,5 85 nm,8 db/km,8 db/km nm,8 db/km,8 db/km *km 5 MHz*km *km 5 MHz*km *km 5 MHz*km *km 5 MHz*km *km *km Fibre capacity GBASE-SR m 8 m m 55 m Fibre capacity BASE-SX 7 m 6 m m m Fibre capacity GBASE-SR/GBASE-SR m 7 m Proof test

74

fire resistant cables

fire resistant cables Building Technology fire resistant cables Special electrical and optical cables www.tecnikabel.com Special electrical and optical cables 2 INTRODUCTION Structured cabling solutions. Tecnikabel can provide

More information

HELKAMA. Optical Fibre Cables

HELKAMA. Optical Fibre Cables 1 Contents Optical fibres and their characteristics Cable constructions Cable tests Installation, jointing and terminating Manufacturing (pictures) 2 Multimode Fibre (GK) Attenuation and Bandwidth Fibre

More information

Caledonian Flame Retardant Coaxial Cables

Caledonian Flame Retardant Coaxial Cables Caledonian Flame Retardant Coaxial Cables www.caledonian-cables.co.uk www.addison-cables.com Flame Retardant RG59 Coaxial cables LSZH Outer Sheath Tinned Copper Braid Aluminium+polyester/Aluminium Tape

More information

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design. ADDISON Flame Retardant RG59 B/U Coaxial cables Plain copper wire braid PE Solid Bare Copper PVC Outer Sheath APPLICATION The cables are designed for CCTV, security, smoke detection and evacuation monitoring

More information

GUCN. Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection v13.

GUCN. Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection v13. GUCN Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection 07-07-05 v3.0 Ordering Information Belden Part Numbers Fibre Description

More information

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red OFC-UT-CST Fire resistant Armoured Indoor/Outdoor steel tape armoured (CST) double LSHF-FR sheathed optical cable with 2 24 fibres. VDE: A/I-DQ(ZN)H(SR)H 3rd party verification of the fire tests by BUREAU

More information

Duct Cable GYTS-144B1.3

Duct Cable GYTS-144B1.3 Optical Fibre Cable Technical Specification Duct Cable GYTS-144B1.3 Xcom Ltd All rights reserved 1. Scope This Specification covers the design requirements and performance standard for the supply of optical

More information

GCRG. Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection v7.0. Ordering Information.

GCRG. Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection v7.0. Ordering Information. GCRG Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection 05-05-7 v7.0 Ordering Information Belden Part Numbers Fibre Description / count 4 8 8 4 30 36 6.5/5-OM GCRG04

More information

Easy to install in ducts, tunnels and trenches by means of compressed air or pulling wire. Suitable for direct burial (crush 400 N/cm).

Easy to install in ducts, tunnels and trenches by means of compressed air or pulling wire. Suitable for direct burial (crush 400 N/cm). GCDG Multi Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)H(SR)H Full Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count

More information

FIRE RESISTANT CABLES

FIRE RESISTANT CABLES Conducting Value The Last Cable Standing FIRE RESISTANT CABLES 100/7b ISO 9001:2008 Certificate No. CS1-249 MANAGEMENT SYSTEMS Assessed to ISO 9001:2008 Cert/LPCB ref. 217 GOST ISO 9001-2011 (ISO 9001:2008)

More information

High Performance LSZH Fire Resistant Cable

High Performance LSZH Fire Resistant Cable High Performance LSZH Fire Resistant Cable www.cavicel.com 104/2 FIRECEL SR 114H is the long and well established CAVICEL fire resistant cable in the market, since many years. These cables are third party

More information

Flame Retardant Overall Screened Instrumentation Cables (multicore)

Flame Retardant Overall Screened Instrumentation Cables (multicore) Flame Retardant Overall Screened Instrumentation Cables (multicore) RE-2X(St)H RE-2X(St)HSWAH LSZH Outer Sheath Tinned Copper Drain Wire LSZH Inner Sheath XLPE Insulation Plain Annealed Copper Aluminium/polyester

More information

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission ADDISON Flame Retardant CAT5e Data Cables FTX-CAT5e U/UTP4P24 FTX-CAT5e f/utp4p24 FTX-CAT5e sf/utp4p24 LSZH Outer Aluminium/Polyester Tape Solid Copper Conductor PE Insulation Tinned Copper Drain Wire

More information

Optical Fibre Cable Technical Specification. Duct Cable GYTA-72B1.3

Optical Fibre Cable Technical Specification. Duct Cable GYTA-72B1.3 VersionGYTA-72B1.3 Optical Fibre Cable Technical Specification Duct Cable GYTA-72B1.3 Yangtze Optical Fibre and Cable Joint Stock Limited Company All rights reserved www.yofc.com All Rights Reserved Copyright

More information

Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive

Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive Illustrations Principle diagram Page 1/7 Product specification installation cable U-DQ(ZN)BH universal fiber optic cable for indoors/outdoors with central or stranded loose tube bend insensitive fiber

More information

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1 Page 1/9 Illustrations Principle diagram See enlarged drawings at the end of document Product specification connection cable I-V(ZN)HH breakout cable for direct connector termination for indoors and outdoors

More information

outdoor and indoor campus backbone, building backbone (riser) FDDI, Gigabit Ethernet and ATM Easy to install direct burial halogen-free

outdoor and indoor campus backbone, building backbone (riser) FDDI, Gigabit Ethernet and ATM Easy to install direct burial halogen-free GUSN Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection 05-04-8 v0.0 Ordering Information Belden Part Numbers Fibre Description / count 4 6 8 6 4

More information

Catalogue Telecommunication Cables INTRODUCCIÓN

Catalogue Telecommunication Cables INTRODUCCIÓN Catalogue Telecommunication Cables INTRODUCCIÓN Conductores Tecnológicos S.A. www.contecsa.es Index of Cables Page Introduction 3 EAP / EAP-R 4 EAPSP / EAPSP-R 5 ISP / ICP 6 Conductores Tecnológicos S.A.

More information

OPTICAL. Micromodule DW About Us. > IEC nd Ed. According to. > EN nd Ed. FTTx

OPTICAL. Micromodule DW About Us. > IEC nd Ed. According to. > EN nd Ed. FTTx fibrewave About Us Prysmian is a global market leader in optical cables, supplying a major part of the world s optical cable needs. With a strong heritage of highly advanced R&D, Prysmian is at the leading

More information

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red Indoor/Outdoor steel tape armoured (CST) double LSHF-FR sheathed optical cable with 2 24 fibres. VDE: A/I-DQ(ZN)H(SR)H 3rd party verification of the fire tests by BUREAU VERITAS December 2014 OFC-UT-CST

More information

CONSTRUCTION PRODUCTS REGULATION MOLEX CES COPPER AND FIBRE CABLE

CONSTRUCTION PRODUCTS REGULATION MOLEX CES COPPER AND FIBRE CABLE CONSTRUCTION PRODUCTS REGULATION MOLEX CES COPPER AND FIBRE CABLE Carol Harris, EMEA Product Manager WHITE PAPER Molex Connected Enterprise Solutions EXECUTIVE SUMMARY Combustible construction materials

More information

Ø 1000 * 588 mm 50 kg

Ø 1000 * 588 mm 50 kg GUCN Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count

More information

Data sheet OpDAT mini breakout cable 24x1 OM4 - bend insensitive

Data sheet OpDAT mini breakout cable 24x1 OM4 - bend insensitive Page 1/8 Illustrations Principle diagram See enlarged drawings at the end of document Product specification mini-breakout installation cable U-VQ(ZN)H laser-optimized, bend insensitive fiber UV-resistant,

More information

GBRD. Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection. Ordering Information. Applications. Features & Benefits

GBRD. Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection. Ordering Information. Applications. Features & Benefits GBRD Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count 24 36 48 60 72 62.5/125-OM1 GBRD124 GBRD136 GBRD148 GBRD160

More information

Belcom Cable excellence engineered through quality. CPR Construction Products Regulation

Belcom Cable excellence engineered through quality. CPR Construction Products Regulation CPR Construction Products Regulation Index Construction Products Regulation... 3 What is the Construction Products Regulation (CPR)... 4 What is the objective of the CPR... 4 Who does the application of

More information

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+) Page 1 / 7 Construction and tests. Standards: UNE 211025 Compliance with the Low Voltage Directive (LVD): 2014/35 / EU Construction Products Regulation (CPR) - Regulation (EU) Nº 305/2011: Reaction to

More information

Caledonian Fire resistant Coaxial Cables

Caledonian Fire resistant Coaxial Cables Caledonian Fire resistant Coaxial Cables www.caledonian-cables.net www.addison-cables.com Fire resistant rg59 b/u Coaxial Cables RG59 B/U FR LSZH Sheath Fire Resistant Tape Copper Clad Steel/Bare Copper

More information

PRODUCT CATALOGUE Norröna

PRODUCT CATALOGUE  Norröna PRODUCT CATALOGUE Norröna WWW.SCANKAB.COM Table of contents MARINE AND OFFSHORE CABLES 1 TOXFREE XZ1-K (AS) - 0.6/1 kv 1 TOXFREE MARINE XO2TCuZ1-K (AS) - 150/250 V 5 4x2xAWG 24/1 CAT6 S/FTP LSZH-SHF1 -

More information

DNVGL-CP-0402 Edition February 2016

DNVGL-CP-0402 Edition February 2016 CLASS PROGRAMME Type approval DNVGL-CP-0402 Edition February 2016 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD

More information

Üntel is ready for CPR

Üntel is ready for CPR 2016 Üntel is ready for CPR Hakan Kubas Marketing Manager 01.11.2016 Construction Products Regulation What is the CPR? The Construction Products Regulation (CPR) lays down conditions for the placing or

More information

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores)

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores) Caledonian Flame Retardant Power & Control Cables www.caledonian-s.co.uk www.addison-s.com 600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores) FTX400 1RZ1MZ1-R (CU/XLPE/LSZH/DSTA/LSZH

More information

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission Flame Retardant RS485 Databus Cables Copper Wire Braid(optional) Individual AL/Polyester Tape(optional) Foam PE/Foam skin PE. Stranded Tinned Copper AL/Polyester Tape With Tinned Copper Drain Wire LSZH

More information

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers Features and Benefits Corrugated armor Mechanical protection Low-smoke/zero-halogen (LSZH ) sheath Key life-safety benefit Meets cyclic impact and chemical resistance test Superior performance Tray-rated

More information

White paper. Construction Product Regulations* by Multimedia Connect. Which cables are concerned by these new regulations?

White paper. Construction Product Regulations* by Multimedia Connect. Which cables are concerned by these new regulations? White paper by Multimedia Connect Construction Product Regulations* We are all concerned by the safety of persons and property. In 2010, 8 million fires were recorded: they are estimated to have caused

More information

Introduction.

Introduction. Introduction The safety of occupants and users of public, commercial and industrial premises is of paramount importance. One important safety feature is the appropriate use of fire performance cables for

More information

Catalogue. Instrumentation & Control Cables

Catalogue. Instrumentation & Control Cables Catalogue Instrumentation & Control Cables Conductores Tecnológicos S.A. www.contecsa.es Index of Cables Page Introduction 3 Instrumentation VOV 4 VHOV 5 VOVMV 6 VHOVMV 7 Control RV 8 RZ1C3Z1 9 Conductores

More information

Telecommunication Cables

Telecommunication Cables Telecommunication Cables Telecommunication Cables Introduction 3 EAP / EAP-R 4 EAPSP / EAPSP-R 5 ISP / ICP 6 Page ELECWIRES 2 www.elecwires.es INTRODUCCIÓN Telecommunication Cables Telephone cables suitable

More information

GUSN. Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection. Ordering Information.

GUSN. Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection. Ordering Information. GUSN Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count 2 4 6 8 12 16 24 62.5/125-OM1

More information

Firecel Safety Cables

Firecel Safety Cables 103/7 Firecel Safety Cables Low Smoke - Zero Halogen www.cavicel.com Firecel Safety Cables Low Smoke - Zero Halogen Over the last 30 years CAVICEL has developped a deep experience in studying, designing

More information

GUSA. Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection. Ordering Information.

GUSA. Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection. Ordering Information. GUSA Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count 2 4 6 8 12 62.5/125-OM1

More information

TELECOM SOLUTIONS CABLE CATALOGUE INNOVATIVE FIBRE OPTIC CABLE SOLUTIONS

TELECOM SOLUTIONS CABLE CATALOGUE INNOVATIVE FIBRE OPTIC CABLE SOLUTIONS TELECOM SOLUTIONS CABLE CATALOGUE INNOVATIVE FIBRE OPTIC CABLE SOLUTIONS TKF TECHNOLOGICAL LEADERSHIP IN CONNECTIVITY SOLUTIONS Since its establishment in 90 TKF developed from a cable producer to a leading

More information

Multipurpose Cables (indoor/outdoor), Multipurpose central tube cable (maxibundle) with glass yarn armouring A-DQ(BN)H 4-24

Multipurpose Cables (indoor/outdoor), Multipurpose central tube cable (maxibundle) with glass yarn armouring A-DQ(BN)H 4-24 Features and Benefits Laminated swelling glass yarns Improved rodent resistance and longitudinal water protection UV and microbe resistant Can be directly buried or installed in ducts Metal-free cable

More information

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION Fire alarm cables for highest safety requirements TRADITION INNOVATION PASSION Datwyler Datwyler Cabling Solutions is an internationally operating company with its headquarters in Switzerland and affiliates

More information

BT Cables Technical Seminar CIBSE South Wales Region. Nov 17

BT Cables Technical Seminar CIBSE South Wales Region. Nov 17 BT Cables Technical Seminar CIBSE South Wales Region Nov 17 Agenda Introductions and BT Cables overview Construction Products Regulation Cables for BMS: A Technical Overview Q&A s Toby Collins Mark Froggatt

More information

Fibre Optic Cable. Catalogue.

Fibre Optic Cable. Catalogue. Fibre Optic Cable Catalogue www.fibrefab.com About The FibreFab Group FibreFab Established in 1992, FibreFab is a leading provider of fibre optic connectivity products used in data communications and Telecommunication

More information

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores) 600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores) FFX400 1SZ1-R(PH60)(CU/SR/LSZH 600/1000V Class 2) FFX400 1SZ1-F(PH60)(CU/SR/LSZH 600/1000V Class 5) Silicone Rubber Insulation Plain

More information

Caledonian fire Resistant signal & Data cables

Caledonian fire Resistant signal & Data cables fire Resistant signal & Data cables www.addison-tech.com fire Resistant Rs485 Databus cables Copper Wire Braid(optional) Individual AL/Polyester Tape(optional) Mica Glass Tape+PE/PE+Silicone Rubber Insulation

More information

Catalogue Power Cables

Catalogue Power Cables Catalogue Power Cables Conductores Tecnológicos S.A. www.contecsa.es Index of Cables Page Introduction 13 RV 14 RVMV 15 RVSV 16 RVFV 17 Conductores Tecnológicos S.A. 2 www.contecsa.es INTRODUCTION Power

More information

Sumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber

Sumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber Sumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber PureGuide -LA SM Optical Fiber, TIA Type IVd ITU G.655 C and D Compliant Issued:

More information

Cable technology for highest safety requirements

Cable technology for highest safety requirements Cable technology for highest safety requirements Daetwyler We are a provider of high-grade quality system solutions and services in the areas of structured data cabling, telecom carriers, safety cabling,

More information

GOF Indoor and Outdoor Cables. Documentation VWL Version 1.1 Source Code M

GOF Indoor and Outdoor Cables. Documentation VWL Version 1.1 Source Code M GOF Indoor and Outdoor Cables Documentation VWL 064.503 Version 1.1 Source Code M GOF Installation Cables Cable matrix / overview Source code M Use Indoor In- / Outdoor Outdoor Type of cable Breakout Mini-

More information

Core identification code. J-YY...BD Indoor Cable. J-YY...BD Indoor Cable. VDE 0815 Mutual capacitance. J-YY...BD Indoor Cable. Cu conductor 0.

Core identification code. J-YY...BD Indoor Cable. J-YY...BD Indoor Cable. VDE 0815 Mutual capacitance. J-YY...BD Indoor Cable. Cu conductor 0. Indoor cables J-YY...BD Indoor J-Y(ST)Y..LG Indoor Comparable products UNITRONIC J-2Y(ST)Y...ST III BD see page 271 Indoor telephone cables transmit analogue or digital signals In news and communication

More information

GOF Indoor and Outdoor Cables. Documentation VWL Version 2.2 Source Code R

GOF Indoor and Outdoor Cables. Documentation VWL Version 2.2 Source Code R GOF Indoor and Outdoor Cables Documentation VWL 064.504 Version 2.2 Source Code R GOF Installation Cables Cable matrix / overview Source code: R Use Indoor In- / Outdoor Outdoor Type of cable Breakout

More information

Construction Products Regulation (CPR) and BS 6701

Construction Products Regulation (CPR) and BS 6701 Construction Products Regulation (CPR) and BS 6701 What you need to know Nancy De Clerck Product Manager Nexans Cabling Solutions Construction Products Regulation (CPR) Scope Performance classifications

More information

Sumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber. PureGuide SM Optical Fiber, TIA Type IVd. Issued: November 2003

Sumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber. PureGuide SM Optical Fiber, TIA Type IVd. Issued: November 2003 Sumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber PureGuide SM Optical Fiber, TIA Type IVd Issued: November 2003 78 Alexander Drive, Research Triangle Park, NC 27709 Phone

More information

DNVGL-CP-0401 Edition February 2016

DNVGL-CP-0401 Edition February 2016 CLASS PROGRAMME Type approval DNVGL-CP-0401 Edition February 2016 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD

More information

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour. 67 POWERFLEX RV-K POWERFLEX RV-K Industrial flexible cable for power transmission. 1 IEC 60502-1 - UNE 21123-2 DESIGN 1. Conductor 2 Electrolytic copper, class 5 (flexible), based on EN 60228 and IEC 60228.

More information

INTERIM EUROPEAN I-ETS TELECOMMUNICATION June 1997 STANDARD

INTERIM EUROPEAN I-ETS TELECOMMUNICATION June 1997 STANDARD INTERIM EUROPEAN I-ETS 300 644 TELECOMMUNICATION June 1997 STANDARD Source: ETSI TC-TM Reference: DI/TM-01021 ICS: 33.020 Key words: Fibre, cable, optical, transmission Transmission and Multiplexing (TM);

More information

Havells Fire Survival Cables

Havells Fire Survival Cables Fire Survival Cables Designed for Critical Installation of National Importance Airports / Thermal Power Plants Metro Rail Projects / Rail Terminals / Nuclear Interstate Bus Terminals / Installation Prone

More information

Lloyd s Register Type Approval System Test Specification Number 3

Lloyd s Register Type Approval System Test Specification Number 3 Working together for a safer world Lloyd s Register Type Approval System Test Specification Number 3 July 2015 Performance Test Specification for Equipment to be used in Marine Applications: Electric Cables

More information

Power Cables. Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7. ELECWIRES 2 Page

Power Cables. Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7. ELECWIRES 2  Page Power Cables Power Cables Page Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7 ELECWIRES 2 www.elecwires.es INTRODUCTION Power Cables Power cables for electrical installations, domestic & industrial, specifically

More information

DNVGL-CP-0399 Edition March 2016

DNVGL-CP-0399 Edition March 2016 CLASS PROGRAMME Type approval DNVGL-CP-0399 Edition March 2016 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD

More information

THE TRUE FIRE SURVIVAL CABLE

THE TRUE FIRE SURVIVAL CABLE 25 YEAR THE TRUE FIRE SURVIVAL CABLE WARRANTY In 1989 we developed a unique process of manufacturing continuous mineral insulated copper cables. THE TRUE FIRE SURVIVAL CABLE We are the only UK manufacturer

More information

Evolution of Cable Fire Safety Standards in Australia

Evolution of Cable Fire Safety Standards in Australia Evolution of Cable Fire Safety Standards in Australia INTRODUCTION Fire safety standards for electrical cables have evolved over the past few decades to the extent that they are now well established along

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60092-350 Second edition 2001-06 Electrical installations in ships Part 350: Shipboard power cables General construction and test requirements Installations électriques à bord

More information

Multi-Core Fire Resistant Cable

Multi-Core Fire Resistant Cable Fire Resistant Cables / Multi-Core Fire Resistant Cable Approved to UL 444, Zeta ZFP series cables have received UL approval for standard applications. Standards Alarm Cable Z UL 444 Approval CMH Rated

More information

Compact Module. Category 6A FTP Cabling System 1.1

Compact Module. Category 6A FTP Cabling System 1.1 Updated 24/09/12 Compact Module Cat 6A performance Suitable for 10-Gigabit Ethernet Ultra-slimline design Euro style module Interchangeable with other Euro Modules and blanks Individually QA tested Easy

More information

YOUR GUIDE TO UNDERSTANDING CPR

YOUR GUIDE TO UNDERSTANDING CPR YOUR GUIDE TO UNDERSTANDING CPR WITH EXCEL NETWORKING SOLUTIONS ISSUE 2 UPDATED JANUARY 2018 WWW.EXCEL-NETWORKING.COM CONTENTS What is CPR? When will this happen? Why the update? Which products are affected?

More information

CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag

CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag STANDARD COLOR CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag TECHNICAL DATA SHEET Revision Number. 1 Last Edited 9. januar 2019 OTHER COLORS MATERIAL Flat band cross linked polyolefin. OPERATING

More information

Tratos Railway Cables

Tratos Railway Cables January 2013 Tratos Railway Cables Cables for a moving world www.tratos.eu Introduction Tratos Cavi is a company specialising in the production of power, signalling, control and telecommunications cables

More information

FIRE PERFORMANCE CABLE

FIRE PERFORMANCE CABLE FIRE PERFORMANCE CABLE Manufactured to BS 7629-1 Table 1 Plain Annealed Copper Conductors / Silicone Rubber Insulated / Double Layer of Aluminium/ Polyester Laminated Tapes / Circuit Protective Conductor

More information

ENHANCED FIRE PERFORMANCE CABLE

ENHANCED FIRE PERFORMANCE CABLE FIRE PERFORMANCE CABLE Manufactured to BS 7629-1 Table 1 Plain Annealed Copper Conductors / Silicone Rubber Insulated / Glass Fibre Tape / Tinned Copper Circuit Protective Conductor / Double Layer of Copper/Polyester

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Presley House Presley Way Crownhill Milton Keynes MK8 0ES United Kingdom Contact: Jeremy Hodge Tel: +44 (0) 1908 267300 Fax: +44 (0) 1908

More information

Fibre Specification Standards

Fibre Specification Standards Fibre Specification Standards User Manual The most important thing we build is trust Cobham Wireless - Coverage Table of Contents 1. Single-mode Fibre to ITU-T Recommendation G.652 3 2. SC/APC Mated Pair

More information

BS /1000V XLPE Insulation LSZH Sheath Cables

BS /1000V XLPE Insulation LSZH Sheath Cables BS 8573 600/1000V XLPE Insulation LSZH Sheath Cables Caledonian www.addison-cables.com Company Profile Caledonian & Addison, branded under Caledoniea & Addimax, established in 1978, offers one of the most

More information

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2017/C 298/02)

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2017/C 298/02) C 298/14 EN Official Journal of the European Union 8.9.2017 Commission communication in the framework of the implementation of Directive 2014/35/EU of the European Parliament and of the Council on the

More information

Fibre optic media options and trends

Fibre optic media options and trends Fibre optic media options and trends Presented by D Stockton & P Lascelles of Miniflex Ltd, branded as m2fx 23 February 2012 1 Contents Cable constructs Indoor/outdoor LSZH Armouring Micro Bends Singlemode,

More information

Table of Contents. TELE-FONIKA KABLE SA (DMCC Branch). 4 TELE-FONIKA Kable Group 6 FLAME-X 950 SERIES 1 11 FLAME-X 950 SERIES 2

Table of Contents. TELE-FONIKA KABLE SA (DMCC Branch). 4 TELE-FONIKA Kable Group 6 FLAME-X 950 SERIES 1 11 FLAME-X 950 SERIES 2 FLAME-X 950 TELE-FONIKA KABLE SA (DMCC Branch). Table of Contents is the Regional Middle East Sales Office of Tele-Fonika Kable S.A. from Poland, 4-th largest manufacturer of electric cables and wires

More information

Special Provision No. 683S28 December 2017

Special Provision No. 683S28 December 2017 FIBRE OPTIC COMMUNICATION CABLES, AERIAL ON MESSENGER CABLE - Item No. FIBRE OPTIC COMMUNICATION CABLES, AERIAL ON MESSENGER CABLE (TEMPORARY) - Item No. Special Provision No. 683S28 December 2017 1. SCOPE

More information

Caledonian. FIREFLIX ire Resistant Coaxial Cables

Caledonian. FIREFLIX ire Resistant Coaxial Cables Caledonian FIREFLIX ire Resistant Coaxial Cables table OF COntents Fire resistant Coaxial Cables Fire Resistant RG59 B/U coaxial cables...25 Fire Resistant RG6 A/U coaxial cables...28 Fire Resistant RG6

More information

(Notices) EUROPEAN COMMISSION

(Notices) EUROPEAN COMMISSION 14.8.2012 Official Journal of the European Union C 245/1 IV (Notices) NOTICES FROM EUROPEAN UNION INSTITUTIONS, BODIES, OFFICES AND AGENCIES EUROPEAN COMMISSION Commission communication in the framework

More information

SAS Security and Alarm Safety Cables

SAS Security and Alarm Safety Cables CABLES Security and Alarm Safety Cables Security and Alarm Safety Cables LOW SMOKE ZERO HALOGEN The right range of cables for modern building installations e-catalogue 203/4 Flexible solutions for commercial,

More information

Comtran Cable. Hub-LINK Cables for Transit Applications

Comtran Cable. Hub-LINK Cables for Transit Applications Comtran Cable Hub-LINK Cables for Transit Applications Overview Hub-LINK rail transit cables are designed to resist the rugged conditions of the underground and at-grade environments, including: Temperature

More information

Traction Cable Radox 3 GKW

Traction Cable Radox 3 GKW General Properties : Excellent high temperature, low temperature, ozone and weathering resistance, zero halogen, flame retardant, solder iron resistant, easily strippable, flexible. Application : Single

More information

The Quality Connection. BETAflam Fire Resistant Safety Cables

The Quality Connection. BETAflam Fire Resistant Safety Cables The Quality Connection BETAflam Fire Resistant Safety Cables BETAflam Contact Your personal customer number To offer you a more efficient service, we kindly ask you to mention your personal customer number

More information

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES CORFLEX TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES INDEX Instrumentation Cables - Pairs and Triads (0V*)... 2 - The Original MC-HL Technology In 1958 Canada Wire and Cable, which s now part of Nexans,

More information

CORRIGENDA. (Publication of titles and references of harmonised standards under Union harmonisation legislation)

CORRIGENDA. (Publication of titles and references of harmonised standards under Union harmonisation legislation) C 173/162 EN Official Journal of the European Union 13.5.2016 CORRIGENDA Corrigendum to Commission communication in the framework of the implementation of Directive 2006/95/EC of the European Parliament

More information

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES INDEX Corflex MC-HL Instrumentation - Pairs and Triads (0V*)... 1 - CORFLEX Cables

More information

Total Fire Solutions. Includes BS 8519 and the updated BS :

Total Fire Solutions. Includes BS 8519 and the updated BS : Total Fire Solutions Includes BS 8519 and the updated BS 5266-1:2011 www.aeicables.co.uk Introduction: Total Fire Solutions Power and control cable systems for life safety and fire-fighting applications

More information

FIRE RESISTANT CABLES FP400

FIRE RESISTANT CABLES FP400 FIRE RESISTANT CABLES FP400 FIRE RESISTANT CABLES FP400 BS7846-F2 CABLE CHARACTERISTICS FP400 APPROVALS INSTALLATION Certificate No 077b Certificate No 517b > Prysmian FP400 is the original fire resistant

More information

industry solutions: military

industry solutions: military industry solutions: military MC industry Solutions: Military A tradition of leadership in technology, product performance for military applications Optical Cable Corporation is a leading manufacturer of

More information

OIL & GAS INDUSTRY OTHER INDUSTRIES

OIL & GAS INDUSTRY OTHER INDUSTRIES For ATEX Areas OIL & GAS INDUSTRY OTHER INDUSTRIES OIL & GAS INDUSTRY POTENTIALLY HAZARDOUS Class I GASES VAPORS LIQUIDS Petrosumsave Zone 0 An area in which an explosive mixture is continuously present,

More information

UK Direction BS7671 BS 8492 BS /01/2018

UK Direction BS7671 BS 8492 BS /01/2018 UK Direction BS7671 BS 8492 BS6701 23/01/2018 BS7671:2015 The 17 th Edition Revision 3 details the requirements for an improved fire rating on all cables within a fire route. 422.2.1 In conditions BD2

More information

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable. Product Specification 108-93018 25/Aug/2011 Rev H Copper LAN cable 1. SCOPE 1.1. Content This specification describes the general requirements for AMP NETCONNECT* copper LAN cable. 2. APPLICABLE DOCUMENTS

More information

Photovoltaic Cables EN H1Z2Z2-K

Photovoltaic Cables EN H1Z2Z2-K Photovoltaic Cables EN 50618 H1Z2Z2-K COMPANY PROFILE Caledonian, established in 1978, offers one of the most complete lines of fiber and copper cabling system solutions with over hundreds of different

More information

CONTENTS. Introduction Customer Service BS codes of practice BS Fire Performance Cable Selection Guide... 7

CONTENTS. Introduction Customer Service BS codes of practice BS Fire Performance Cable Selection Guide... 7 CONTENTS Page Introduction... 1 Customer Service... 2 BS codes of practice BS 8519... 5 Fire Performance Cable Selection Guide... 7 FlamBICC Introduction...8 FlamBICC 1...10 FlamBICC 2...12 FlamBICC 3...14

More information

ZH Low Smoke 0-Halogen Flameretardant Identification Sleeves

ZH Low Smoke 0-Halogen Flameretardant Identification Sleeves STANDARD TUBE COLOR ZH Low Smoke 0-Halogen Flameretardant Identification Sleeves TECHNICAL DATA SHEET Revision Number. 1 Last Edited 24. juli 2018 The ZH-2X Heat Shrinkable Wire Markers are made of halogen

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61156-6 First edition 2002-03 Multicore and symmetrical pair/quad cables for digital communications Part 6: Symmetrical pair/quad cables with transmission characteristics up

More information

13. UNITED KINGDOM Standards Supply Voltage and Plug Configurations 247

13. UNITED KINGDOM Standards Supply Voltage and Plug Configurations 247 13. UNITED KINGDOM 13.1 Standards 13.1.1 BSI 240 13.1.2 BASEC 242 13.1.3 BBC 242 13.1.4 BNFL 242 13.1.5 BRB 242 13.1.6 British Telecom 243 13.1.7 Department of the Environment 243 13.1.8 Department for

More information

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore)

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore) 600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore) FGD400 1RV-R (CU/XLPE/PVC 600/1000V Class ) FGD400 1RVMV-R (CU/XLPE/PVC/SWA/PVC 600/1000V Class ) PVC Outer Sheath Plain Annealed

More information