TELECOM SOLUTIONS CABLE CATALOGUE INNOVATIVE FIBRE OPTIC CABLE SOLUTIONS

Size: px
Start display at page:

Download "TELECOM SOLUTIONS CABLE CATALOGUE INNOVATIVE FIBRE OPTIC CABLE SOLUTIONS"

Transcription

1 TELECOM SOLUTIONS CABLE CATALOGUE INNOVATIVE FIBRE OPTIC CABLE SOLUTIONS

2

3 TKF TECHNOLOGICAL LEADERSHIP IN CONNECTIVITY SOLUTIONS Since its establishment in 90 TKF developed from a cable producer to a leading supplier of connectivity solutions located in the Netherlands. A broad range of cables, systems and services enables us to provide our customers worldwide with safe and reliable power and data connections. Due to a focused commitment, TKF is distinguished by specialized application knowledge and solutions with a high degree of reliability, quality and service. Specialized technical know-how and flexibility lead to a high return on investment for our customers. TKF is characterized by continuous investment in customer relations, quality and supplementary services, resulting in sustainable cable solutions and long-term and successful relationships. It goes without saying that we offer our customized solutions with respect for people and environment. Being part of the technology company TKH Group NV, TKF has access to breakthrough solutions, concepts and technologies. More than 85 years of experience Our market segmentation Our core values Building Solutions»» Building»» Energy»» Infrastructure»» Renewable»» Rail infra Industrial Solutions»» Industry»» Marine & offshore»» Oil, gas & petrochemical Telecom Solutions»» Telecom»» Innovativeness»» Maximum reliability»» Outstanding quality»» High service degree»» Corporate Social Responsibility 5

4 MEET THE TKH GROUP AND ITS CORE TECHNOLOGIES TKH Group NV (TKH) is an internationally operating group of companies specialized in creating and supplying innovative Telecom, Building and Industrial Solutions. All TKH technologies are interlinked into total solutions for these three business segments. Specialists in the fields of marketing, process development, design, engineering and logistics add advice and project implementation to offer a tailor-made solution. TKH aims to carve out strong market positions based mainly on its own advanced technologies and services and on its strong regional and international positioning. The group s growth is concentrated in North-Western, Central and Eastern Europe and in Asia. TKH is known for its innovations and its commitment to renewal. The urge to lead is great. TKH places its experience and knowledge into the service of its clients, and jointly looks for optimal solutions. The four TKH core technologies: Vision & Security Communications Connectivity Manufacturing Systems 6

5 CONTENTS TOTAL SOLUTIONS FOR MODERN FIBRE OPTIC NETWORKS 6 Indoor cables Micro Drop Installation Cables flat 0 Micro Drop Installation Cables round STIC Simplex Cables 6 Duplex cables ZIP 8 Breakout cables 0 Distribution-cables Outdoor cables CTC ADSS LTC ADSS-0 6 LTC ADSS-80 8 LTC ADSS-50 0 LTC ADSS-50 DAC CTC 6 LTC-S 8 LTC 0 LTC-S Rodent Protected LTC Rodent Protected LTC Poly-Amide 6 DAC MT 8 CTC CS 50 LTC CS 5 LTC JF MT SWA 5 Universal cables MADC 56 STAC 58 D-DAC LSZH 6 CTC LSZH 6 LTC-S LSZH 65 LTC-S Rodent Protected LSZH 67 CTC HFFR 69 LTC-S HFFR 7 CTC CS LSZH 7 LTC CS LSZH 75 CTC CS HFFR 77 LTC-S CS HFFR 79 CTC CS FR 8 Mini cables Loose Tube Mini Cables 8 Loose Tube Mini Cables 00um 85 Loose Tube Mini Cables PA 87 Central Tube Mini Cables 89 5 Micro cables MUC 9 SFU 9 TECHNICAL PRODUCT INFORMATION 95 TELECOM SOLUTIONS 7 CABLE DRUM SIZES AND WEIGHTS 8 MORE INFORMATION 9 7

6 TOTAL SOLUTIONS FOR MODERN FIBRE OPTIC NETWORKS The demand for broadband solutions is constantly rising. That means that the number of fibre optic networks is also increasing worldwide. The size and topology of these networks vary by region. Therefore, TKF is constantly innovating in the field of Telecom Solutions. For improved, flexible, cost-saving and easy to install solutions. Our ACE concept As a total solutions supplier within the TKH Group NV, TKF developed the ACE concept, a total solution for modern fibre optic networks. ACE is a certified and guaranteed concept for passive FTTx networks. As a total concept ACE provides the broadband market with a new vision on building fibre optic networks. ACE does not only consist of products, but also guarantees compatibility between all the different components and offers complete, passive solutions. 8

7 The ACE concept is mainly a success of people. People with knowledge and skills concentrated in the ACE team. Together with our customers we share technical knowledge and help our customers to stay ahead with our continuous developments. ACE not only has the right products, but also ensures that the various components fit together seamlessly in the fields of application: POP, OSP and Subscriber. 9

8 POP Solutions Building a FTTx network starts at the drawing board where configuration, technology and planning are defined. One of the most challenging parts of the network is the POP (point of presence). This is the centre (heart) of the network where all connections are made and active equipment is installed and operated. It is essential to exclude all possible risks during and operation. TKF has gathered all its experience and know-how within the ACE concept, to cover the full range of options to achieve an optimal POP performance. POP s need to be built close to the subscribers. Moreover they need to fit into this environment and meet the requirements of the subscribers on construction, size, shape, colour, noise and place. TKF has set up a flexible design that meets all demands. A street cabinet solution or a large POP building, they all fit within the ACE concept. The ACE POP solution offers: Flexible design High and super high density ODF Optional SAODF (semi-automated ODF) Third operator solution Partial delivery or turnkey solution OSP Solutions Civil work is the major cost driver (>70%) of the total cost ofownership (TCO), to build FTTx networks. The cost of civil work vary from country to country, sandy or rocky soil and paving: tiles, concrete or no paving at all, make a big difference in cost. Within the ACE concept TKF offers solutions for each OSP network to lower the cost per individual challenge. Direct burial cable solution: Within the ACE concept, TKF has developed a full range of products making the of a direct burial cable concept easy and cost saving. Heavy duty steel or Kevlar protected cables are available together with all components, like closures and access chambers that fit in this application. Modular cabling solution: In order to meet the various demands (success based s) it is often required to use a modular cabling system in FTTx networks. ACE offers a full modular cable solution including all accessories like closures, duct connectors, fibre blowing equipment and a special ODF, for easy of all tubes within the POP or street cabinet. 0

9 Aerial solution: In case of existing aerial infrastructure (f.i. power lines), it can be cost saving to use this infrastructure to install a FTTx network. ACE offers a full range of ADSS cables suitable for this application. TKF has experience with sewer paths and fibre through gas pipelines. To prevent expensive digging operations, TKF has looked at all the different trenching possibilities, like macro and nano trenching. All these cost saving solutions can be fully integrated within the ACE concept with warranty and certification. All these solutions and options require tailor made products and systems. TKF has developed a total ACE subscriber solution for both single and multi dwelling units (SDU and MDU), that fit all these demands and still keep the cost low. Special indoor and outdoor cables have been developed. And a full series of fibre splice and patch boxes are available in all required sizes and shapes, designed and tested for this challenging environment. Subscriber Solutions The main challenge when building a FTTx network is getting access to the subscriber. As we are operating within the public sector, possible challenges are: Availability of subscribers during office hours Wishes and demands of house and building owners Local regulations and cooperation of all subscribers in the chain: - Are we allowed to install on the outside of the building? - Can we install in hallways, cellars or elevator shafts?

10 Indoor cables Micro Drop Installation Cables flat Indoor cables Properties The Micro Drop Installation Cable (MDIC) is a special Access cable with low bend radius, no waterpeak G.657.A fibres. Ruggedized construction with excellent performance, easy strippable for fast. This cable solves all in-house problems. Specifications Product group Fibre optic cable Type MDIC LSZH Application Inside Optical fibre standard ITU-T G.657.A Fibre type Single mode 9/5 Cable metal free Strip method Double sided Rip seam Strain relief Material outer sheath LSZH Colour outer sheath White Test procedures IEC Longitudinal water blocking No Installation temperature -0 / 50 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C UV resistant UV-protection ISO 89/ Max. 0 nm 0. db/km Max. 550 nm 0. db/km Vertical Flame Propagation (for Single Cable) IEC / EN Vertical Flame Spread (for Bunched Cables) IEC 60-- / EN (Cat.C)

11 Indoor cables Micro Drop Installation Cables flat products Part number Dimension (height - width) Net weight (kg/km) radius after radius during short term (Tm) 697 x SM G.657.A.0 / long term (Tl) Indoor cables

12 Indoor cables Micro Drop Installation Cables round Indoor cables Properties The Micro Drop Installation Cable (MDIC) is a special Access cable with low bend radius, no waterpeak G.657.A fibres. Ruggedized construction with excellent performance, easy strippable for fast. This cable solves all in-house problems. Specifications Product group Fibre optic cable Type MDIC LSZH Fibre type Single mode 9/5 Optical fibre standard ITU-T G.657.A Cable metal free Strip method Double sided Rip seam Strain relief Material outer sheath LSZH Colour outer sheath White Application Inside Test procedures IEC Longitudinal water blocking No Installation temperature -0 / 50 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C UV resistant UV-protection ISO 89/ Max. 0 nm 0. db/km Max. 550 nm 0. db/km Vertical Flame Propagation (for Single Cable) IEC / EN Vertical Flame Spread (for Bunched Cables) IEC 60-- / EN (Cat.C)

13 Indoor cables Micro Drop Installation Cables round 5 products Part number Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) 6977 x SM G.657.A x SM G.657.A x SM G.657.A x SM G.657.A x SM G.657.A long term (Tl) Indoor cables 5

14 Indoor cables STIC Indoor cables Properties STIC Soft Tube Indoor Cable This special indoor cable with bend-insensitive fibre G.657.A, protected by easy strippable soft tube, meets all requirements for modern building cabling: a small diameter, low weight, high tensile force and excellent bend and crush performance. Its easy, fast strippable sheath consist of special flame retardant LSZH-material, making the cable extremely robust, but flexible, with its 90 bend radius capability. Consequently, the STIC is perfectly suitable to be installed on the wall by using e.g. staples or glue. Due to its (semi-)dry construction, this cable is highly safe and can be used in any human habitation. The dry soft tube makes also easier its into the vertical riser shafts of MDU s. Specifications Product group Fibre optic cable Type STIC Fibre type Single mode 9/5 Optical fibre standard ITU-T G.657.A Type of tube Soft tube Cable metal free Strain relief Material outer sheath LSZH Colour outer sheath White Application Inside Suitable for indoor Simulated according IEC E7 90 degree bends (R=mm) possible Standardization EN IEC Test procedures IEC Longitudinal water blocking Longitudinal watertight construction Super Absorbing Polymer Installation temperature -0 / 50 C Transportation and storage temperature -5 / 60 C Operational temperature range Ta - Tb -0 / 50 C Operational temperature range Ta - Tb -5 / 60 C Max. 0 nm 0. db/km Max. 550 nm 0. db/km Max. 65 nm 0. db/km Halogen free IEC 6075-& / EN & Vertical Flame Propagation (for Single Cable) IEC 60-- / EN

15 Indoor cables STIC 9 products Part number Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) x SM G.657.A x SM G.657.A (x) x SM G.657.A (x) x SM G.657.A (x) x SM G.657.A (x6) x SM G.657.A (x6) x SM G.657.A (x) 7990 x SM G.657.A (x6) 7990 x SM G.657.A (x) long term (Tl) Indoor cables 7

16 Indoor cables Simplex Cables Indoor cables Properties The simplex cable consists of one dry-buffered, easy strip low bend radius, no waterpeak G.657.A fibre, tensile elements of aramid yarns and a loose low smoke halogen-free outer jacket. The simplex cable is suitable for direct connector assembly. This cable is suitable for indoor in dry rooms, inside of telecommunication- and datasystems. Specifications Product group Fibre optic cable Type Simplex Application Inside Optical fibre standard ITU-T G.657.A Colour outer sheath Yellow Fibre type Single mode 9/5 Type of tube Product dependent Cable metal free Strain relief Material outer sheath LSZH Standardization EN IEC Test procedures IEC Installation temperature -5 / 5 C Transportation and storage temperature Product dependent Operational temperature range Ta - Tb Product dependent Max. attenuation increase during Ta - Tb 0. db Max. 0 nm 0. db/km Max. 550 nm 0. db/km Max. 65 nm 0. db/km Halogen free IEC 6075-& / EN & Vertical Flame Propagation (for Single Cable) IEC / EN

17 Indoor cables Simplex Cables 5 products Part number 6967 x SM G.657.A. mm 695 x SM G.657.A.6 mm 695 x SM G.657.A.0 mm 695 x SM G.657.A. mm 695 x SM G.657.A.8 mm Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) long term (Tl) Indoor cables 9

18 Indoor cables Duplex cables ZIP Indoor cables Properties The duplex cable consists of simplex cables, parallel laying in a figure 8 design (duplex zip cord). The duplex cable is suitable for direct connector assembly and is used for indoor in dry rooms, inside of telecommunication- and datasystems. Specifications Product group Fibre optic cable Type Duplex Fibre type Single mode 9/5 Optical fibre standard ITU-T G.657.A Type of tube Product dependent Cable metal free Strain relief Material outer sheath LSZH Colour outer sheath Yellow Application Inside Standardization EN IEC Test procedures IEC Longitudinal water blocking No Radial water blocking No Installation temperature -5 / 5 C Transportation and storage temperature -5 / 70 C Max. 0 nm 0. db/km Max. 550 nm 0. db/km Max. 65 nm 0. db/km Halogen free IEC 6075-& / EN & Vertical Flame Propagation (for Single Cable) IEC 60-- / EN

19 Indoor cables Duplex cables ZIP products Part number Dimension (height - width) Net weight (kg/km) radius after radius during 6986 ZIP.6 SM G.657.A.6 / ZIP.0 SM G.657.A.0 / ZIP.8 SM G.657.A.8 / short term (Tm) Indoor cables

20 Indoor cables Breakout cables Indoor cables Properties The Breakout cable consists of multiple simplex cables stranded around a central support member, with a low smoke halogenfree outer jacket. The individual simplex cables are suitable for direct connector assembly. This cable is suitable for indoor in dry rooms, inside of telecommunication- and datasystems. Specifications Product group Fibre optic cable Type Break-Out Fibre type Single mode 9/5 Optical fibre standard ITU-T G.657.A Type of tube Simplex.6 Cable metal free Strip method Rip cord Strain relief Material outer sheath LSZH Colour outer sheath Yellow Application Inside Standardization EN IEC Test procedures IEC Longitudinal water blocking No Radial water blocking No Installation temperature -0 / 60 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 60 C Max. 0 nm 0.5 db/km Max. 550 nm 0.5 db/km Halogen free IEC 6075-& / EN & Vertical Flame Propagation (for Single Cable) IEC 60-- / EN

21 Indoor cables Breakout cables 6 products Part number 7706 x SM G.657.A.6 mm (x ) x SM G.657.A.6 mm (8x ) x SM G.657.A.6 mm (x ) x SM G.657.A.6 mm (6x ) x SM G.657.A.6 mm (x ) x SM G.657.A.6 mm (8x ) Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) long term (Tl) Indoor cables

22 Indoor cables Distribution-cables Indoor cables Properties The distribution-cable consists of multiple dry-buffered low bend radius, no waterpeak G.657.A fibres, covered by aramid yarns (strength members), with a low smoke halogen-free outer jacket. The individual fibres are suitable for direct connector assembly. This cable is suitable for indoor in dry rooms, inside of telecommunication- and datasystems. Specifications Product group Fibre optic cable Type Distribution-cable Optical fibre standard ITU-T G.657.A Fibre type Single mode 9/5 Type of tube Dry buffer 0,9mm Cable metal free Strain relief Material outer sheath LSZH Colour outer sheath Yellow Application Inside Standardization EN IEC Test procedures IEC Longitudinal water blocking No Radial water blocking No Installation temperature -5 / 5 C Transportation and storage temperature -5 / 70 C Max. 0 nm 0. db/km Max. 550 nm 0. db/km Max. 65 nm 0. db/km Halogen free IEC 6075-& / EN & Vertical Flame Propagation (for Single Cable) IEC 60-- / EN

23 Indoor cables Distribution-cables products Part number Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) 698 x SM G.657.A (x) x SM G.657.A (8x) x SM G.657.A (x) 698 x SM G.657.A (x) long term (Tl) Indoor cables 5

24 Outdoor cables - Aerial - Metalfree CTC ADSS Outdoor cables Properties The Central Tube Cable All Dielectric Self Supporting Cable (CTC ADSS) is an aerial central tube cable with low bend radius, no waterpeak G.657.A fibres and dry-waterblocking aramid yarns underneath the polyethylene outer sheath. This FttX-cable is intended for use as an aerial customer drop cable. This cable is designed for spans between approx. 0 and 50 mtrs, depending on installing and surroundings conditions, with the conditions from the NESC tables as a basis. For further information, please consult document Sag & Tension Calculations under characteristic Specification. Specifications Product group Fibre optic cable Type CTC ADSS Fibre type Single mode 9/5 Optical fibre standard ITU-T G.657.A Type of tube Loose tube, gel filled Cable metal free Strain relief Material outer sheath PE (polyethylene) Colour outer sheath Black Application Outside Blowable Standardization EN IEC Test procedures IEC Longitudinal water blocking Longitudinal watertight construction Super Absorbing Polymer Installation temperature -5 / 50 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.05 db Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.5 db UV resistant Max. 0 nm 0. db/km Max. 550 nm 0. db/km Max. 65 nm 0. db/km 6

25 Outdoor cables - Aerial - Metalfree CTC ADSS 5 products Part number Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) 7760 x SM G.657.A x SM G.657.A x SM G.657.A x SM G.657.A x SM G.657.A long term (Tl) Outdoor cables 7

26 Outdoor cables - Aerial - Metalfree LTC ADSS-0 Outdoor cables Properties The Loose Tube Cable All Dielectric Self-Supporting (LTC ADSS) is a metalfree aerial distribution cable, with dry waterblocking and aramid yarns under the outersheath. This cable is to be used under all dielectric circumstances, for example on distribution and medium/low voltage power lines, railway, tram, trolley bus lines and between buildings. Because of its strong tensile members it is suitable for aerial applications without using additional strenght members. This cable is designed for spans between approx. 0 and 80 mtrs, depending on installing and surroundings conditions, with the conditions from the NESC tables as a basis. For further information, please consult document Sag & Tension Calculations under characteristic Specification. Specifications Product group Fibre optic cable Type LTC ADSS-0 Fibre type Single mode 9/5 Optical fibre standard ITU-T G.657.A Type of tube Loose tube, gel filled Cable metal free Strip method Rip cord Strain relief Material outer sheath HDPE Colour outer sheath Black Application Outside Blowable Standardization EN IEC Test procedures IEC Longitudinal water blocking Longitudinal watertight construction Super Absorbing Polymer Installation temperature -5 / 50 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.05 db Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.5 db UV resistant UV-protection ISO 89/ Max. 0 nm 0.5 db/km Max. 550 nm 0. db/km Max. 65 nm 0.5 db/km 8

27 Outdoor cables - Aerial - Metalfree LTC ADSS-0 products Part number Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) x SM G.657.A (x) x SM G.657.A (x) x SM G.657.A (x) x SM G.657.A (x6) x SM G.657.A (6x) x SM G.657.A (x6) x SM G.657.A (8x6) x SM G.657.A (x) x SM G.657.A (6x) x SM G.657.A (8x) x SM G.657.A (x) long term (Tl) Outdoor cables 9

28 Outdoor cables - Aerial - Metalfree LTC ADSS-80 Outdoor cables Properties The Loose Tube Cable All Dielectric Self-Supporting (LTC ADSS) is a metalfree aerial distribution cable, with dry waterblocking and aramid yarns under the outersheath. This cable is to be used under all dielectric circumstances, for example on distribution and high voltage power lines, railway, tram, trolley bus lines and between buildings. Because of its strong tensile members it is suitable for aerial applications without using additional strenght members. This cable is designed for spans between approx. 80 and 60 mtrs, depending on installing and surroundings conditions, with the conditions from the NESC tables as a basis. For further information, please consult document Sag & Tension Calculations under characteristic Specification. Specifications Product group Fibre optic cable Type LTC ADSS-80 Fibre type Single mode 9/5 Optical fibre standard ITU-T G.657.A Type of tube Loose tube, gel filled Cable metal free Strip method Rip cord Strain relief Material outer sheath HDPE Colour outer sheath Black Application Outside Standardization EN IEC Test procedures IEC Longitudinal water blocking Longitudinal watertight construction Super Absorbing Polymer Installation temperature -5 / 55 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.05 db Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.5 db UV resistant Max. 0 nm 0.5 db/km Max. 550 nm 0. db/km Max. 65 nm 0. db/km 0

29 Outdoor cables - Aerial - Metalfree LTC ADSS-80 products Part number Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) x SM G.657.A (6x) x SM G.657.A (x6) x SM G.657.A (6x) x SM G.657.A (x) x SM G.657.A (x) 7 8x SM G.657.A (6x8) x SM G.657.A (x) x SM G.657.A (6x) x SM G.657.A (8x) x SM G.657.A (x) x SM G.657.A (6x) x SM G.657.A (8x) x SM G.657.A (9x) long term (Tl) Outdoor cables

30 Outdoor cables - Aerial - Metalfree LTC ADSS-50 Outdoor cables Properties The Loose Tube Cable All Dielectric Self-Supporting (LTC ADSS) is a metalfree aerial distribution cable, with dry waterblocking and aramid yarns under the outersheath. This cable is to be used under all dielectric circumstances, for example on distribution and high voltage power lines, railway, tram, trolley bus lines and between buildings. Because of its strong tensile members it is suitable for aerial applications without using additional strenght members. This cable is designed for spans between approx. 50 and 00 mtrs, depending on installing and surroundings conditions, with the conditions from the NESC tables as a basis. For further information, please consult document Sag & Tension Calculations under characteristic Specification. Specifications Product group Fibre optic cable Type LTC ADSS-50 Colour outer sheath Black Fibre type Single mode 9/5 Optical fibre standard ITU-T G.657.A Type of tube Loose tube, gel filled Cable metal free Strip method Rip cord Strain relief Material outer sheath HDPE Application Outside Standardization EN IEC Test procedures IEC Longitudinal water blocking Longitudinal watertight construction Super Absorbing Polymer Installation temperature -5 / 55 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.05 db Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.5 db UV resistant Max. 0 nm 0.8 db/km Max. 550 nm 0. db/km Max. 65 nm 0.6 db/km

31 Outdoor cables - Aerial - Metalfree LTC ADSS-50 9 products Part number Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) x SM G.657.A (6x) x SM G.657.A (6x) x SM G.657.A (x) x SM G.657.A (6x8) x SM G.657.A (x) x SM G.657.A (6x) x SM G.657.A (8x) x SM G.657.A (5x) x SM G.657.A (6x) long term (Tl) Outdoor cables

32 Outdoor cables - Aerial - Metalfree LTC ADSS-50 Outdoor cables Properties The Loose Tube Cable All Dielectric Self-Supporting (LTC ADSS) is a metalfree aerial distribution cable, with dry waterblocking and aramid yarns under the outersheath. This cable is to be used under all dielectric circumstances, for example on distribution and high voltage power lines, railway, tram, trolley bus lines and between buildings. Because of its strong tensile members it is suitable for aerial applications without using additional strenght members. This cable is designed for spans between approx. 50 and 50 mtrs, depending on installing and surroundings conditions, with the conditions from the NESC tables as a basis. For further information, please consult document Sag & Tension Calculations under characteristic Specification. Specifications Product group Fibre optic cable Type LTC ADSS-50 Colour outer sheath Black Fibre type Single mode 9/5 Optical fibre standard ITU-T G.657.A Type of tube Loose tube, gel filled Cable metal free Strain relief Material outer sheath HDPE Application Outside Standardization EN IEC Test procedures IEC Longitudinal water blocking Longitudinal watertight construction Super Absorbing Polymer Installation temperature -5 / 55 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.05 db Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.5 db UV resistant Max. 0 nm 0.8 db/km Max. 550 nm 0. db/km Max. 65 nm 0.6 db/km

33 Outdoor cables - Aerial - Metalfree LTC ADSS-50 8 products Part number Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) long term (Tl) x SM G.657.A (6x) x SM G.657.A (6x) x SM G.657.A (x) x SM G.657.A (6x8) x SM G.657.A (x) x SM G.657.A (6x) x SM G.657.A (8x) x SM G.657.A (6x) Outdoor cables 5

34 Outdoor cables - Underground - Metalfree DAC Outdoor cables Properties The Direct Access Cable (DAC) is a light-weight, non-metallic, central tube direct-buried Access cable with low bend radius, no waterpeak G.657.A fibres, with small diameter for easy, longitudinally water-protected. This cable has a very high crush resistance and tensile strenght, is fast strippable (over > meter in one stroke). Due to extra strenght-members in the cable outersheath, this central tube design has an improved temperature range. Installation: direct burial application. Also blowable in (mini)tubes over a limited distance. Specifications Product group Fibre optic cable Type DAC Fibre type Single mode 9/5 Optical fibre standard Product dependent Type of tube Loose tube, gel filled Cable metal free Strain relief Material outer sheath Polypropylene Colour outer sheath Orange Application Outside Blowable No Standardization EN IEC Test procedures IEC Longitudinal water blocking Longitudinal watertight construction Super Absorbing Polymer Radial water blocking No Installation temperature -0 / 50 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C UV resistant UV-protection ISO 89/ Max. 0 nm Product dependent Max. 550 nm Product dependent Max. 65 nm Product dependent 6

35 Outdoor cables - Underground - Metalfree DAC 6 products Part number Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) x SM G.657.A x SM G.657.A x SM G.657.A x SM G.657.A x SM G.657.A x SM G.657.A 00µm long term (Tl) Outdoor cables 7

36 Outdoor cables - Underground - Metalfree CTC Outdoor cables Properties The Central Tube Cable (CTC) is a light-weight, non-metallic, central tube outdoor duct cable with small diameter, rodent protected, longitudinal water-protected. Installation: by blowing or pulling, into conduits or on cable trays. Specifications Product group Fibre optic cable Type CTC Fibre type Single mode 9/5 Optical fibre standard ITU-T G.657.A Type of tube Loose tube, gel filled Cable metal free Strain relief Material outer sheath PE (polyethylene) Colour outer sheath Black Application Outside Blowable Test procedures IEC Longitudinal water blocking Longitudinal watertight construction Super Absorbing Polymer Radial water blocking No Installation temperature -5 / 50 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.05 db Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.5 db UV resistant Max. 0 nm 0.8 db/km Max. 550 nm 0. db/km Max. 65 nm 0.5 db/km 8

37 Outdoor cables - Underground - Metalfree CTC products Part number Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) 7506 x SM G.657.A x SM G.657.A x SM G.657.A x SM G.657.A x SM G.657.A x SM G.657.A x SM G.657.A x SM G.657.A x SM G.657.A x SM G.657.A x SM G.657.A long term (Tl) Outdoor cables 9

38 Outdoor cables - Underground - Metalfree LTC-S Outdoor cables Properties The Loose Tube Cable Slim (LTC-S) is a non-metallic, loose tube outdoor duct cable, longitudinal water-protected. Due to its slim design (small diameter and light in weight), this cable is perfectly suitable for in ducts with limited space. Installation: by blowing or pulling, into conduits or on cable trays. Specifications Product group Fibre optic cable Type LTC-S Fibre type Single mode 9/5 Optical fibre standard ITU-T G.657.A Type of tube Loose tube, gel filled Cable metal free Strip method Rip cord Strain relief Material outer sheath HDPE Colour outer sheath Black Application Outside Blowable Standardization EN IEC Test procedures IEC Longitudinal water blocking Longitudinal watertight construction Super Absorbing Polymer Installation temperature -5 / 55 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.05 db Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.5 db UV resistant Max. 0 nm 0.5 db/km Max. 550 nm 0. db/km Max. 65 nm 0.5 db/km 0

39 Outdoor cables - Underground - Metalfree LTC-S 6 products Part number x SM G.657.A (x) x SM G.657.A (x) x SM G.657.A (x) 776 8x SM G.657.A (x) x SM G.657.A (5x) 776 7x SM G.657.A (6x) 776 8x SM G.657.A (7x) x SM G.657.A (8x) x SM G.657.A (9x) x SM G.657.A (0x) 7767 x SM G.657.A (x) x SM G.657.A (x) 7777 x SM G.657.A (6x) x SM G.657.A (8x) x SM G.657.A (9x) x SM G.657.A (x) Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) long term (Tl) Outdoor cables

40 Outdoor cables - Underground - Metalfree LTC Outdoor cables Properties The Loose Tube Cable (LTC) is a non-metallic, loose tube outdoor duct cable, longitudinal water-protected. Installation: by blowing or pulling, into conduits or on cable trays. Specifications Product group Fibre optic cable Type LTC Application Outside Colour outer sheath Black Fibre type Single mode 9/5 Optical fibre standard ITU-T G.657.A Type of tube Loose tube, gel filled Cable metal free Strip method Rip cord Strain relief Material outer sheath PE (polyethylene) Blowable Standardization EN IEC Test procedures IEC Longitudinal water blocking Longitudinal watertight construction Super Absorbing Polymer Installation temperature -5 / 55 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.05 db Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.5 db UV resistant UV-protection ISO 89/ Max. 0 nm 0.5 db/km Max. 550 nm 0. db/km Max. 65 nm 0.5 db/km

41 Outdoor cables - Underground - Metalfree LTC products Part number Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) 7500 x SM G.657.A (x) x SM G.657.A (x) x SM G.657.A (x) x SM G.657.A (6x) x SM G.657.A (x) x SM G.657.A (x6) x SM G.657.A (6x) x SM G.657.A (x6) x SM G.657.A (6x6) x SM G.657.A (8x6) x SM G.657.A (6x8) x SM G.657.A (6x) x SM G.657.A (8x) x SM G.657.A (x) x SM G.657.A ((5+)x) 75 88x SM G.657.A ((9+5)x) 75 8x SM G.657.A ((5+)x) 75 x SM G.657.A ((6+)x) x SM G.657.A ((9+5)x) 755 6x SM G.657.A ((0+6)x) x SM G.657.A ((5++6)x) x SM G.657.A ((6++8)x) 709 9x SM G.657.A ((7++8)x) long term (Tl) Outdoor cables

42 Outdoor cables - Underground - Metalfree LTC-S Rodent Protected Outdoor cables Properties The Loose Tube Cable Slim Rodent-Protected (LTC-S RP) is a nonmetallic, loose tube outdoor duct cable, rodent protected, longitudinal water-protected, with high pulling force. Due to its slim design (small diameter and light in weight), this cable is perfectly suitable for in ducts with limited space. Installation: by blowing or pulling, into conduits or on cable trays. Specifications Product group Fibre optic cable Type LTC-S RP Application Outside Optical fibre standard ITU-T G.657.A Colour outer sheath Black Fibre type Single mode 9/5 Type of tube Loose tube, gel filled Cable metal free Strip method Rip cord Strain relief Material outer sheath HDPE Blowable Standardization EN IEC Test procedures IEC Longitudinal water blocking Longitudinal watertight construction Super Absorbing Polymer Installation temperature -5 / 55 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.05 db Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.5 db UV resistant UV-protection ISO 89/ Max. 0 nm 0.5 db/km Max. 550 nm 0. db/km Max. 65 nm 0.5 db/km

43 Outdoor cables - Underground - Metalfree LTC-S Rodent Protected 7 products Part number Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) 7780 x SM G.657.A (x) x SM G.657.A (x) x SM G.657.A (x) x SM G.657.A (6x) x SM G.657.A (6x) x SM G.657.A (x) x SM G.657.A (x6) x SM G.657.A (x) x SM G.657.A (x) x SM G.657.A (6x) x SM G.657.A (6x) x SM G.657.A (x6) x SM G.657.A (x) x SM G.657.A (6x6) x SM G.657.A (x) x SM G.657.A (8x6) x SM G.657.A (6x8) x SM G.657.A (x) x SM G.657.A (5x) x SM G.657.A (6x) x SM G.657.A (8x) x SM G.657.A (0x) x SM G.657.A (x) x SM G.657.A (6x) x SM G.657.A (8x) x SM G.657.A (9x) x SM G.657.A (x) long term (Tl) Outdoor cables 5

44 Outdoor cables - Underground - Metalfree LTC Rodent Protected Outdoor cables Properties The Loose Tube Cable Rodent-Protected (LTC RP) is a robust, nonmetallic, loose tube outdoor duct cable, rodent protected, longitudinal water-protected, with high pulling force. Installation: by blowing or pulling, into conduits or on cable trays. Specifications Product group Fibre optic cable Type LTC RP Application Outside Optical fibre standard ITU-T G.657.A Colour outer sheath Black Fibre type Single mode 9/5 Type of tube Loose tube, gel filled Cable metal free Strip method Rip cord Strain relief Material outer sheath HDPE Blowable Standardization EN IEC Test procedures IEC Longitudinal water blocking Installation temperature -5 / 55 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.05 db Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.5 db UV resistant UV-protection ISO 89/ Max. 0 nm 0.5 db/km Max. 550 nm 0. db/km Max. 65 nm 0.5 db/km 6

45 Outdoor cables - Underground - Metalfree LTC Rodent Protected products Part number Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) 759 6x SM G.657.A (x) x SM G.657.A (x) x SM G.657.A (6x) x SM G.657.A (x) x SM G.657.A (x6) x SM G.657.A (6x) x SM G.657.A (x6) x SM G.657.A (6x6) x SM G.657.A (8x6) x SM G.657.A (6x8) x SM G.657.A (5x) x SM G.657.A (6x) x SM G.657.A (8x) x SM G.657.A (0x) x SM G.657.A (x) x SM G.657.A ((5+)x) x SM G.657.A ((9+5)x) 757 8x SM G.657.A ((5+)x) 757 x SM G.657.A ((6+)x) x SM G.657.A ((9+5)x) x SM G.657.A ((0+6)x) x SM G.657.A ((5++6)x) x SM G.657.A ((6++8)x) 758 9x SM G.657.A ((7++8)x) long term (Tl) Outdoor cables 7

46 Outdoor cables - Underground - Metalfree LTC Poly-Amide Outdoor cables Properties The Loose Tube Cable Polyamid (LTC PA) is a non-metallic, loose tube outdoor duct cable, longitudinal water-protected with a polyamid (PA) outersheath (termite-protection). Installation: suitable for duct or direct buried (under condition of clean backfill), by pulling or blowing. Specifications Product group Fibre optic cable Type LTC PA Fibre type Single mode 9/5 Optical fibre standard ITU-T G.657.A Type of tube Loose tube, gel filled Cable metal free Strip method Rip cord Strain relief Material outer sheath PE / polyamide Colour outer sheath Black Application Outside Blowable Standardization EN IEC Test procedures IEC Longitudinal water blocking Longitudinal watertight construction Super Absorbing Polymer Installation temperature -5 / 55 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.05 db Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.5 db UV resistant UV-protection ISO 89/ Termite protected Max. 0 nm 0.5 db/km Max. 550 nm 0. db/km Max. 65 nm 0.5 db/km 8

47 Outdoor cables - Underground - Metalfree LTC Poly-Amide 7 products Part number Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) 775 x SM G.657.A (6x) x SM G.657.A (6x) x SM G.657.A (6x6) x SM G.657.A (x) 775 7x SM G.657.A (6x) x SM G.657.A (8x) 7759 x SM G.657.A (x) long term (Tl) Outdoor cables 9

48 Outdoor cables - Underground - Metallic - Unarmoured DAC MT Outdoor cables Properties The Direct Access Cable Metallic (DAC MT) is a direct-buried metallic Central Tube Cable, with tracking-wire for detection of the cable in the ground. Light-weight, metallic, central tube directburied Access cable with low bend radius, no waterpeak G.657.A fibres, with small diameter for easy, longitudinally water-protected. This cable has a very high crush resistance and tensile strenght, is fast strippable (over > meter in one stroke). Due to extra strenght-members in the cable outersheath, this central tube design has an improved temperature range. Installation: direct burial application. Specifications Product group Fibre optic cable Type DAC MT Optical fibre standard ITU-T G.657.A Colour outer sheath Orange Fibre type Single mode 9/5 Type of tube Loose tube, gel filled Cable metal free No Strain relief Material outer sheath Polypropylene Application Outside Blowable No Test procedures IEC Longitudinal water blocking Longitudinal watertight construction Super Absorbing Polymer Radial water blocking No Installation temperature -0 / 50 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C UV resistant UV-protection ISO 89/ Max. 0 nm 0.8 db/km Max. 550 nm 0.5 db/km Max. 65 nm 0.8 db/km 50

49 Outdoor cables - Underground - Metallic - Unarmoured DAC MT products Part number Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) 75 x SM G.657.A x SM G.657.A long term (Tl) Outdoor cables 5

50 Outdoor cables - Underground - Metallic - Armoured CTC CS Outdoor cables Properties The Central Tube Cable Corrugated Steel (CTC CS) is a metallic, central tube outdoor cable, with longitudinally watertight cablecore, armoured with corrugated steel tape (excellent rodent resistance). Installation: Pulling into conduits, on cable trays or directly buried. Specifications Product group Fibre optic cable Type CTC CS Optical fibre standard ITU-T G.657.A Fibre type Single mode 9/5 Type of tube Loose tube, gel filled Cable metal free No Strip method Rip cord Strain relief Material outer sheath PE (polyethylene) Colour outer sheath Black Application Outside Test procedures IEC Longitudinal water blocking Product dependent Longitudinal watertight construction Super Absorbing Polymer Radial water blocking Installation temperature -5 / 60 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.05 db UV resistant UV-protection ISO 89/ Rodent resistant Max. 0 nm 0.8 db/km Max. 550 nm 0.5 db/km Max. 65 nm 0.8 db/km 5

51 Outdoor cables - Underground - Metallic - Armoured CTC CS 0 products Part number Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) 7505 x SM G.657.A x SM G.657.A x SM G.657.A x SM G.657.A x SM G.657.A x SM G.657.A x SM G.657.A x SM G.657.A x SM G.657.A x SM G.657.A long term (Tl) Outdoor cables 5

52 Outdoor cables - Underground - Metallic - Armoured LTC CS Outdoor cables Properties The Loose Tube Cable Corrugated Steel (LTC CS) is a metallic loose tube outdoor cable, armoured with corrugated steel tape (excellent rodent resistance), longitudinal water-protected. Installation: Pulling into conduits, on cable trays or directly buried. Specifications Product group Fibre optic cable Type LTC CS Application Outside Colour outer sheath Black Fibre type Single mode 9/5 Optical fibre standard ITU-T G.657.A Type of tube Loose tube, gel filled Cable metal free No Strip method Rip cords Strain relief Material outer sheath HDPE Blowable Standardization EN IEC Test procedures IEC Longitudinal water blocking Longitudinal watertight construction Super Absorbing Polymer Installation temperature -5 / 55 C Transportation and storage temperature -5 / 70 C Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.05 db Operational temperature range Ta - Tb -5 / 70 C Max. attenuation increase during Ta - Tb 0.5 db UV resistant UV-protection ISO 89/ Rodent resistant Max. 0 nm 0.5 db/km Max. 550 nm 0. db/km Max. 65 nm 0.5 db/km 5

53 Outdoor cables - Underground - Metallic - Armoured LTC CS 7 products Part number Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) 7898 x SM G.657.A (x6) x SM G.657.A (x) x SM G.657.A (x) x SM G.657.A (6x) x SM G.657.A (8x) x SM G.657.A (x) x SM G.657.A ((9+5)x) long term (Tl) Outdoor cables 55

54 Outdoor cables - Underwater LTC JF MT SWA Outdoor cables Properties LTC JF MT SWA Heavy duty underwater cable Loose tube cable with armoring of galvanized steel wires for excellent resistance against crush, impact and tensile forces and heavily protected against water ingress, by means of cable jelly filling and aluminium tape. This cable is suitable to be installed in fresh- or saltwater for a water-depth of max. 50m. Installation: in sewer systems, water pressurized tunnels, lake and river crossings or shorelines (coastal application) Specifications Product group Fibre optic cable Type LTC JF MT SWA Fibre type Single mode 9/5 Optical fibre standard ITU-T G.657.A Type of tube Loose tube, gel filled Strip method Rip cord Strain relief Material outer sheath HDPE Colour outer sheath Black Application Outside Standardization EN IEC Test procedures IEC Longitudinal water blocking Longitudinal watertight construction Jelly Radial water blocking Radial watertight construction Al/PE Installation temperature -5 / 50 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.05 db UV resistant Rodent resistant Max. 0 nm 0.5 db/km Max. 550 nm 0. db/km Max. 65 nm 0.5 db/km 56

55 Outdoor cables - Underwater LTC JF MT SWA 9 products Part number Construction Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) 787 x SM G.657.A (x) x SM G.657.A (6x) x SM G.657.A (6x8) x SM G.657.A (6x8) x SM G.657.A (6x) x SM G.657.A (8x) x SM G.657.A (8x) x SM G.657.A (6x) 78 88x SM G.657.A (x) long term (Tl) Outdoor cables 57

56 Universal cables - Metalfree MADC Universal cables Properties The Mini Aerial Drop Cable (MADC) is a universal metallfree self supporting optical fibre cable, in small design, with low bend radius, no waterpeak G.657.A fibres and dry-waterblocking aramid yarns underneath the LSZH outer sheath. This FttX-cable is intended for in/outdoor use as an aerial customer drop cable, with over short spans. Specifications Product group Fibre optic cable Type MADC Fibre type Single mode 9/5 Optical fibre standard ITU-T G.657.A Cable metal free Strain relief Material outer sheath LSZH Colour outer sheath Black Application Inside/outside Blowable No Standardization EN IEC Test procedures IEC Longitudinal water blocking Longitudinal watertight construction Super Absorbing Polymer Installation temperature -0 / 50 C Transportation and storage temperature -0 / 60 C Operational temperature range Ta - Tb -0 / 50 C Operational temperature range Ta - Tb -5 / 60 C UV resistant UV-protection ISO 89/ Max. 0 nm 0. db/km Max. 550 nm 0. db/km Max. 65 nm 0. db/km Halogen free IEC 6075-& / EN & Vertical Flame Propagation (for Single Cable) IEC 60-- / EN

57 Universal cables - Metalfree MADC 5 products Part number Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) 7986 x SM G.657.A x SM G.657.A x SM G.657.A x SM G.657.A x SM G.657.A long term (Tl) Universal cables 59

58 Universal cables - Metalfree STAC Universal cables Properties STAC Soft Tube Access Cable This special indoor/outdoor drop cable with bend-insensitive fibre G.657.A, protected by easy strippable soft tube, meets all requirements for FTTH access network: a small diameter, low weight, high tensile force and easily strippable features. The STAC is designed to connect the outside branch to customer s termination box without splicing, resulting in reduced -time. This cable consist of a double jacket design, with a 90 bend radius inner subunit (STIC) perfectly suitable for indoor application, a robust outer sheath for outdoor and tensile strength members between both jackets. The outer sheath can be easily removed, when entering the building. Due to its (semi-)dry construction, this cable is highly safe and can be used in any human habitation. The dry soft tube makes also easier its into the vertical riser shafts of MDU s. This multi-purpose cable can be installed by pulling in ducts, on external walls, or aerial between poles. The STAC cable is designed for maximum spans of 50m (or longer, varying per item), according to French Standard NF C - 0A. For further information, please consult document Sag & Tension Calculations under characteristic Specification. Specifications Product group Fibre optic cable Type STAC Fibre type Single mode 9/5 Optical fibre standard ITU-T G.657.A Type of tube Soft tube Cable metal free Strip method Rip cords Strain relief Material outer sheath PE (polyethylene) Colour outer sheath Black Application Outside Standardization EN IEC Test procedures IEC Longitudinal water blocking Longitudinal watertight construction Super Absorbing Polymer Installation temperature -0 / 50 C Transportation and storage temperature -5 / 60 C Operational temperature range Ta - Tb -0 / 50 C Operational temperature range Ta - Tb -5 / 60 C 60

59 Universal cables - Metalfree STAC UV resistant UV-protection ISO 89/ Max. 0 nm 0. db/km Max. 550 nm 0. db/km Max. 65 nm 0. db/km Halogen free IEC 6075-& / EN & Universal cables 6

60 Universal cables Universal cables - Metalfree STAC 9 products Part number Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) x SM G.657.A x SM G.657.A (x) x SM G.657.A (x) x SM G.657.A (x) x SM G.657.A (x6) x SM G.657.A (x6) 7989 x SM G.657.A (x) x SM G.657.A (x6) 7989 x SM G.657.A (x) long term (Tl) 6

61 Universal cables - Metalfree D-DAC LSZH Properties The Dry Direct Access Cable (D-DAC) is a light-weight, nonmetallic, direct-buried customer drop cable for universal applications. This cable is robust, water-protected and has a flame retardant outersheath. The cable has a flexible, easystrippable sheath and small diameter, making it perfectly suitable for indoor routing. The glass-fibres are dry-buffered, for fast and easy stripping and peeling. The D-DAC is suitable for outdoor (directly into the ground, above ground on facades) and indoor (horizontal and vertical cable channels). Especially due to its fully dry design (no jelly), the cable can be applied as riser cable. This cable is intended for connecting homes in high-rise buildings (MDU's) from the last underground distribution-point in the Access network, without any transitionpoints. This product offers a perfect, fast and cost effective solution for Fibre To The Home' connections in MDU s. Universal cables Specifications Product group Fibre optic cable Type D-DAC LSZH Fibre type Single mode 9/5 Optical fibre standard ITU-T G.657.A Cable metal free Strain relief Material outer sheath LSZH Colour outer sheath Black Application Inside/outside Standardization EN IEC Test procedures IEC Longitudinal water blocking Longitudinal watertight construction Super Absorbing Polymer Installation temperature -0 / 50 C Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.05 db Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.5 db UV resistant UV-protection ISO 89/ Max. 0 nm 0.8 db/km Max. 550 nm 0.5 db/km Max. 65 nm 0.0 db/km Halogen free IEC 6075-& / EN & Vertical Flame Propagation (for Single Cable) IEC 60-- / EN

62 Universal cables Universal cables - Metalfree D-DAC LSZH 5 products Part number Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) 7569 x SM G.657.A x SM G.657.A x SM G.657.A x SM G.657.A x SM G.657.A long term (Tl) 6

63 Universal cables - Metalfree CTC LSZH Properties The Central Tube Cable Low Smoke Zero Halogen (CTC LSZH) is a light-weight, non-metallic, universal central tube cable (indoor/outdoor) with small diameter, rodent protected, longitudinal water-protected, with Low Smoke Zero Halogen outersheath. Installation: by blowing or pulling, into conduits or on cable trays. Universal cables Specifications Product group Fibre optic cable Type CTC LSZH Fibre type Single mode 9/5 Optical fibre standard ITU-T G.657.A Type of tube Loose tube, gel filled Cable metal free Strain relief Material outer sheath LSZH Colour outer sheath Black Application Inside/outside Blowable Test procedures IEC Longitudinal water blocking Longitudinal watertight construction Super Absorbing Polymer Radial water blocking No Installation temperature -5 / 50 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.05 db UV resistant Max. 0 nm 0.6 db/km Max. 550 nm 0. db/km Max. 65 nm 0. db/km Vertical Flame Propagation (for Single Cable) IEC 60-- / EN

64 Universal cables Universal cables - Metalfree CTC LSZH 5 products Part number Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) x SM G.657.A x SM G.657.A x SM G.657.A x SM G.657.A x SM G.657.A long term (Tl) 66

65 Universal cables - Metalfree LTC-S LSZH Properties The Loose Tube Cable Slim Low Smoke Zero Halogen (LTC-S LSZH) is a non-metallic, loose tube universal (indoor/outdoor) cable, longitudinal water-protected, with Low Smoke Zero Halogen outersheath. Due to its slim design (small diameter and light in weight), this cable is perfectly suitable for in ducts with limited space. Installation: by blowing or pulling, into conduits or on cable trays. Universal cables Specifications Product group Fibre optic cable Type LTC-S LSZH Colour outer sheath Black Fibre type Single mode 9/5 Optical fibre standard ITU-T G.657.A Type of tube Loose tube, gel filled Cable metal free Strip method Rip cord Strain relief Material outer sheath LSZH Application Inside/outside Blowable Standardization EN IEC Test procedures IEC Longitudinal water blocking Longitudinal watertight construction Super Absorbing Polymer Installation temperature -5 / 55 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.05 db Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.5 db UV resistant UV-protection ISO 89/ Max. 0 nm 0.5 db/km Max. 550 nm 0. db/km Max. 65 nm 0.5 db/km Vertical Flame Propagation (for Single Cable) IEC 60-- / EN

66 Universal cables Universal cables - Metalfree LTC-S LSZH 6 products Part number x SM G.657.A (x) x SM G.657.A (x) x SM G.657.A (x) x SM G.657.A (x) x SM G.657.A (5x) x SM G.657.A (6x) x SM G.657.A (7x) x SM G.657.A (8x) x SM G.657.A (9x) x SM G.657.A (0x) x SM G.657.A (x) x SM G.657.A (x) x SM G.657.A (6x) x SM G.657.A (8x) x SM G.657.A (9x) x SM G.657.A (x) Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) long term (Tl) 68

67 Universal cables - Metalfree LTC-S Rodent Protected LSZH Properties The Loose Tube Cable Slim Rodent-Protected Low Smoke Zero Halogen (LTC-S RP LSZH) is a non-metallic, loose tube universal (indoor/outdoor) duct cable, rodent protected, longitudinal waterprotected, with Low Smoke Zero Halogen outersheath and high pulling force. Due to its slim design (small diameter and light in weight), this cable is perfectly suitable for in ducts with limited space. Installation: by blowing or pulling, into conduits or on cable trays. Universal cables Specifications Product group Fibre optic cable Type LTC-S RP LSZH Application Inside/outside Optical fibre standard ITU-T G.657.A Colour outer sheath Black Fibre type Single mode 9/5 Type of tube Loose tube, gel filled Cable metal free Strip method Rip cord Strain relief Material outer sheath LSZH Blowable Standardization EN IEC Test procedures IEC Longitudinal water blocking Longitudinal watertight construction Super Absorbing Polymer Installation temperature -5 / 55 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.05 db Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.5 db UV-protection ISO 89/ Max. 0 nm 0.5 db/km Max. 550 nm 0. db/km Max. 65 nm 0.5 db/km Vertical Flame Propagation (for Single Cable) IEC 60-- / EN

68 Universal cables Universal cables - Metalfree LTC-S Rodent Protected LSZH products Part number Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) x SM G.657.A (x) x SM G.657.A (x) x SM G.657.A (x) x SM G.657.A (6x) x SM G.657.A (x) x SM G.657.A (x6) x SM G.657.A (x) x SM G.657.A (x) x SM G.657.A (6x) x SM G.657.A (x6) x SM G.657.A (x) x SM G.657.A (6x6) x SM G.657.A (x) 778 8x SM G.657.A (8x6) x SM G.657.A (6x8) x SM G.657.A (x) x SM G.657.A (5x) x SM G.657.A (6x) x SM G.657.A (0x) 7788 x SM G.657.A (x) 7789 x SM G.657.A (6x) x SM G.657.A (8x) 778 6x SM G.657.A (9x) x SM G.657.A (x) long term (Tl) 70

69 Universal cables - Metalfree CTC HFFR Properties The Central Tube Cable Halogen Free Flame Retardant (CTC HFFR) is a non-metallic, central tube universal (indoor/outdoor) cable, rodent-protected, longitudinal water-protected, with a Halogen Free Flame Retardant outer sheath. This cable meets the requirements for fire safety, in terms of flammability, smoke emission and toxic fume omission and reduces the risk to which people, equipment and buildings are exposed in the event of fire. Therefore, CTC HFFR-cable is perfectly suitable for in tunnels, subway, ship, rail (trains, stations), public buildings, etc. Installation: by blowing or pulling, into conduits or on cable trays. Universal cables Specifications Product group Fibre optic cable Type CTC HFFR Fibre type Single mode 9/5 Optical fibre standard ITU-T G.657.A Type of tube Loose tube, gel filled Cable metal free Strain relief Material outer sheath LSZH Colour outer sheath Orange Blowable Test procedures IEC Longitudinal watertight construction Super Absorbing Polymer Installation temperature -5 / 60 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.05 db UV-protection ISO 89/ Rodent resistant Max. 0 nm 0. db/km Max. 550 nm 0. db/km Max. 65 nm 0. db/km Halogen free IEC 6075-& / EN & Vertical Flame Propagation (for Single Cable) IEC 60-- / EN Vertical Flame Spread (for Bunched Cables) IEC / EN (Cat.D) 7

70 Universal cables Universal cables - Metalfree CTC HFFR products Part number Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) 7576 x SM G.657.A x SM G.657.A long term (Tl) 7

71 Universal cables - Metalfree LTC-S HFFR Properties The Loose Tube Cable Slim Halogen Free Flame Retardant (LTC-S HFFR) is a non-metallic, loose tube universal (indoor/outdoor) cable, rodent-protected, longitudinal water-protected, with a Halogen Free Flame Retardant outer sheath. This cable meets the requirements for fire safety, in terms of flammability, smoke emission and toxic fume omission and reduces the risk to which people, equipment and buildings are exposed in the event of fire. Therefore, LTC-S HFFR-cable is perfectly suitable for in tunnels, subway, ship, rail (trains, stations), public buildings, etc. Installation: by blowing or pulling, into conduits or on cable trays. Universal cables Specifications Product group Fibre optic cable Type LTC-S HFFR Fibre type Single mode 9/5 Optical fibre standard ITU-T G.657.A Type of tube Loose tube, gel filled Cable metal free Strip method Rip cord Strain relief Material outer sheath HFFR Colour outer sheath Orange Application Inside/outside Blowable Standardization EN IEC Test procedures IEC Longitudinal water blocking Longitudinal watertight construction Super Absorbing Polymer Installation temperature -5 / 60 C Transportation and storage temperature -5 / 70 C Operational temperature range Ta - Tb -5 / 70 C Max. attenuation increase during Ta - Tb 0.05 db UV resistant UV-protection ISO 89/ Max. 0 nm 0.5 db/km Max. 550 nm 0. db/km Max. 65 nm 0.5 db/km Halogen free IEC 6075-/ Vertical Flame Propagation (for Single Cable) IEC 60-- / EN Vertical Flame Spread (for Bunched Cables) IEC / EN (Cat.D) 7

72 Universal cables Universal cables - Metalfree LTC-S HFFR products Part number 7776 x SM G.657.A (x) x SM G.657.A (x) x SM G.657.A (x) x SM G.657.A (6x) Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) long term (Tl) 7

73 Universal cables - Metallic CTC CS LSZH Properties The Central Tube Cable Corrugated Steel Low Smoke Zero Halogen (CTC CS LSZH) is a metallic, universal central tube cable (indoor/outdoor), with longitudinally water-protected cable-core, armoured with corrugated steel tape (excellent rodent resistance), with Low Smoke Zero Halogen outersheath. Installation: Pulling into conduits, on cable trays or directly buried. Universal cables Specifications Product group Fibre optic cable Type CTC CS LSZH Fibre type Single mode 9/5 Optical fibre standard ITU-T G.657.A Type of tube Loose tube, gel filled Cable metal free No Strip method Product dependent Strain relief Material outer sheath LSZH Colour outer sheath Black Application Inside/outside Test procedures IEC Longitudinal water blocking Product dependent Longitudinal watertight construction Super Absorbing Polymer Radial water blocking Installation temperature -5 / 50 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.05 db UV resistant UV-protection ISO 89/ Rodent resistant Max. 0 nm 0.8 db/km Max. 550 nm 0.5 db/km Max. 65 nm 0.8 db/km Halogen free IEC 6075-& / EN & Vertical Flame Propagation (for Single Cable) IEC 60-- / EN

74 Universal cables Universal cables - Metallic CTC CS LSZH 0 products Part number Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) 756 x SM G.657.A x SM G.657.A x SM G.657.A x SM G.657.A x SM G.657.A x SM G.657.A x SM G.657.A x SM G.657.A x SM G.657.A x SM G.657.A long term (Tl) 76

75 Universal cables - Metallic LTC CS LSZH Properties The Loose Tube Cable Corrugated Steel Low Smoke Zero Halogen (LTC CS LSZH) is a metallic loose tube universal (indoor/outdoor) cable, armoured with corrugated steel tape (excellent rodent resistance), with Low Smoke Zero Halogen outersheath and longitudinal water-protected. Installation: Pulling into conduits, on cable trays or directly buried. Universal cables Specifications Product group Fibre optic cable Type LTC CS LSZH Application Inside/outside Colour outer sheath Black Fibre type Single mode 9/5 Optical fibre standard ITU-T G.657.A Type of tube Loose tube, gel filled Cable metal free No Strip method Rip cords Strain relief Material outer sheath LSZH Standardization EN IEC Test procedures IEC Longitudinal water blocking Longitudinal watertight construction Super Absorbing Polymer Installation temperature -5 / 60 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.05 db Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.5 db UV resistant UV-protection ISO 89/ Rodent resistant Max. 0 nm 0.5 db/km Max. 550 nm 0. db/km Max. 65 nm 0.5 db/km Vertical Flame Propagation (for Single Cable) IEC 60-- / EN

76 Universal cables Universal cables - Metallic LTC CS LSZH 5 products Part number 7856 x SM G.657.A (x) x SM G.657.A (x) x SM G.657.A (6x) x SM G.657.A (8x) 7860 x SM G.657.A (x) Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) long term (Tl) 78

77 Universal cables - Metallic CTC CS HFFR Properties The Central Tube Cable Corrugated Steel Halogen Free Flame Retardant (CTC CS HFFR) is a metallic, central tube universal (indoor/outdoor) cable, longitudinal water-protected, with corrugated steel tape armoring (excellent rodent resistance) and a Halogen Free Flame Retardant outer sheath. This cable meets the requirements for fire safety, in terms of flammability, smoke emission and toxic fume omission and reduces the risk to which people, equipment and buildings are exposed in the event of fire. Therefore, CTC CS HFFR-cable is perfectly suitable for interbuilding and intrabuilding backbones. Installation: pulling into conduits, on cable trays or directly buried. Universal cables Specifications Product group Fibre optic cable Type CTC CS HFFR Optical fibre standard ITU-T G.657.A Fibre type Single mode 9/5 Type of tube Loose tube, gel filled Cable metal free No Strip method Rip cords Strain relief Material outer sheath HFFR Colour outer sheath Orange Standardization EN IEC Test procedures IEC Longitudinal watertight construction Super Absorbing Polymer Installation temperature -5 / 60 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.05 db UV-protection ISO 89/ Rodent resistant Max. 0 nm 0.8 db/km Max. 550 nm 0.5 db/km Max. 65 nm 0.8 db/km Vertical Flame Propagation (for Single Cable) IEC 60-- / EN Vertical Flame Spread (for Bunched Cables) IEC 60-- / EN (Cat.A) 79

78 Universal cables Universal cables - Metallic CTC CS HFFR products Part number Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) 75 x SM G.657.A x SM G.657.A long term (Tl) 80

79 Universal cables - Metallic LTC-S CS HFFR Properties The Loose Tube Cable Slim Corrugated Steel Halogen Free Flame Retardant (LTC-S CS HFFR) is a metallic, loose tube universal (indoor/outdoor) cable, longitudinal waterprotected, with corrugated steel tape armoring (excellent rodent resistance) and a Halogen Free Flame Retardant outer sheath. This cable meets the requirements for fire safety, in terms of flammability, smoke emission and toxic fume omission and reduces the risk to which people, equipment and buildings are exposed in the event of fire. Therefore, LTC CS HFFR-cable is perfectly suitable for interbuilding and intrabuilding backbones. Installation: pulling into conduits, on cable trays or directly buried. Universal cables Specifications Product group Fibre optic cable Type LTC-S CS HFFR Fibre type Single mode 9/5 Optical fibre standard ITU-T G.657.A Type of tube Loose tube, gel filled Cable metal free No Strip method Rip cords Strain relief Material outer sheath HFFR Colour outer sheath Orange Application Inside/outside Standardization EN IEC Test procedures IEC Longitudinal water blocking Longitudinal watertight construction Super Absorbing Polymer Installation temperature -5 / 60 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -5 / 70 C Max. attenuation increase during Ta - Tb 0.05 db UV-protection ISO 89/ Rodent resistant Max. 0 nm 0.5 db/km Max. 550 nm 0. db/km Max. 65 nm 0.5 db/km Halogen free IEC 6075-/ Vertical Flame Propagation (for Single Cable) IEC 60-- / EN Vertical Flame Spread (for Bunched Cables) IEC 60-- / EN (Cat.A) 8

80 Universal cables Universal cables - Metallic LTC-S CS HFFR products Part number 7867 x SM G.657.A (x) x SM G.657.A (x) x SM G.657.A (x) x SM G.657.A (6x) Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) long term (Tl) 8

81 Universal cables - Metallic CTC CS FR Properties The Central Tube Cable Corrugated Steel Fire Resistant (CTC CS FR) is a fire safety cable with circuit integrity for at least 90 minutes in the event of fire. It s a robust, metallic central tube universal (indoor/outdoor) cable, with fire protective coating, corrugated steel tape armouring (excellent rodent resistance), longitudinal waterprotection and a Halogen Free Flame Retardant outer sheath. This cable meets the requirements for fire safety, ensures datatransmission during and after fire (secured connectivity) and reduces the risk to which people, equipment and buildings are exposed in the event of fire. Therefore, CTC CS FR-cable is perfectly suitable for signal and control circuits in critical infrastructure like tunnels, subway, ship, rail (trains, stations), public buildings, etc. Installation: by pulling, into conduits or on cable trays. Universal cables Specifications Product group Fibre optic cable Type CTC CS FR Optical fibre standard ITU-T G.657.A Fibre type Single mode 9/5 Type of tube Loose tube, gel filled Cable metal free No Strip method Rip cords Strain relief Material outer sheath HFFR Colour outer sheath Red Standardization EN IEC Test procedures IEC Longitudinal watertight construction Super Absorbing Polymer Installation temperature -5 / 50 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.05 db UV-protection ISO 89/ Rodent resistant Max. 0 nm 0.8 db/km Max. 550 nm 0.5 db/km Max. 65 nm 0.8 db/km Halogen free IEC 6075-& / EN & Vertical Flame Propagation (for Single Cable) IEC 60-- / EN Vertical Flame Spread (for Bunched Cables) IEC 60-- / EN (Cat.A) 8

82 Universal cables Universal cables - Metallic CTC CS FR products Part number Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) 75 x SM G.657.A x SM G.657.A long term (Tl) 8

83 Mini cables Loose Tube Mini Cables Properties The Loose Tube Mini Cable (LTMC) is a non-metallic, longitudinal water-protected fibre optic cable, with reduced outer diameter and low bend radius, no waterpeak G.657.A fibres, suitable for Access or FTTx applications. Installation: blowing into miniducts. Mini cables Specifications Product group Fibre optic cable Type LTMC Optical fibre standard ITU-T G.657.A Fibre type Single mode 9/5 Type of tube Loose tube, gel filled Cable metal free Strip method Rip cord Strain relief Material outer sheath HDPE Colour outer sheath Black Application Outside Blowable Standardization EN IEC Test procedures IEC Longitudinal water blocking Longitudinal watertight construction Super Absorbing Polymer Installation temperature -5 / 50 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.05 db UV resistant UV-protection ISO 89/ Max. 0 nm 0.5 db/km Max. 550 nm 0. db/km Max. 65 nm 0.5 db/km 85

84 Mini cables Mini cables Loose Tube Mini Cables 8 products Part number 78 x SM G.657.A (x) 786 x SM G.657.A (x) 78 6x SM G.657.A (x) 785 8x SM G.657.A (x) 78 7x SM G.657.A (6x) 78 96x SM G.657.A (8x) x SM G.657.A (8x) 78 x SM G.657.A (6x) Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) long term (Tl) 86

85 Mini cables Loose Tube Mini Cables 00µm Properties The Loose Tube Mini Cable 00µm (LTMC) is a non-metallic, longitudinal water-protected fibre optic cable, with extra reduced cable-diameter by application of low bend radius, no waterpeak G.657.A 00µm fibres. This cable is perfectly suitable for Access or FTTx applications, where high fibre-count cables in smallest tube-diameter are needed. Installation: blowing into miniducts. Mini cables Specifications Product group Fibre optic cable Type LTMC Optical fibre standard ITU-T G.657.A 00 µm Fibre type Single mode 9/5 Type of tube Loose tube, gel filled Cable metal free Strip method Rip cord Strain relief Material outer sheath HDPE Colour outer sheath Black Application Outside Blowable Standardization EN IEC Test procedures IEC Longitudinal water blocking Longitudinal watertight construction Super Absorbing Polymer Installation temperature -5 / 50 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.05 db UV resistant Max. 0 nm 0.5 db/km Max. 550 nm 0. db/km Max. 65 nm 0.5 db/km 87

86 Mini cables Mini cables Loose Tube Mini Cables 00µm 0 products Part number 770 x SM G.657.A 00 µm (x) 770 6x SM G.657.A 00 µm (x) 770 8x SM G.657.A 00 µm (x) 779 7x SM G.657.A 00 µm (6x) x SM G.657.A 00 µm (8x) 789 x SM G.657.A 00 µm (x) 789 x SM G.657.A 00 µm (6x) 788 9x SM G.657.A 00 µm (8x) 775 6x SM G.657.A 00 µm (9x) x SM G.657.A 00 µm (x) Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) long term (Tl) 88

87 Mini cables Loose Tube Mini Cables PA 00µm Properties The Loose Tube Mini Cable Polyamide 00µm (LTMC PA) is a nonmetallic, longitudinal water-protected fibre optic cable, with reduced outer diameter and low friction polyamide outer-sheath. This cable is perfectly suitable for Access or FTTx applications, where blowing of mini-cable over long distances in shortest possible time slot is needed. Installation: blowing into mini-ducts. Mini cables Specifications Product group Fibre optic cable Type LTMC PA Optical fibre standard ITU-T G.657.A 00 µm Fibre type Single mode 9/5 Type of tube Loose tube, gel filled Cable metal free Strip method Rip cord Strain relief Material outer sheath Polyamide Colour outer sheath Black Application Outside Blowable Standardization EN IEC Test procedures IEC Longitudinal water blocking Longitudinal watertight construction Super Absorbing Polymer Installation temperature -5 / 50 C Transportation and storage temperature -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.05 db Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0.5 db UV resistant Max. 0 nm 0.5 db/km Max. 550 nm 0. db/km Max. 65 nm 0.5 db/km 89

88 Mini cables Mini cables Loose Tube Mini Cables PA 00µm 0 products Part number 7708 x SM G.657.A 00 µm (x) x SM G.657.A 00 µm (x) 770 8x SM G.657.A 00 µm (x) 77 7x SM G.657.A 00 µm (6x) x SM G.657.A 00 µm (8x) 778 x SM G.657.A 00 µm (x) 77 x SM G.657.A 00 µm (6x) 770 9x SM G.657.A 00 µm (8x) 77 6x SM G.657.A 00 µm (9x) x SM G.657.A 00 µm (x) Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) long term (Tl) 90

89 Mini cables Central Tube Mini Cables Properties The Central Tube Mini Cable (CTMC) is a customer drop cable, consisting of a central tube filled with low bend radius, no waterpeak G.657.A fibres, finished with aramid yarns (as strenght-elements) and a polypropylene outer jacket. This cable has a small outside diameter and is ideal for blowing in microtubes in the Access Network. Installation: blowing into microducts of 5.5 mm. (inside diameter) Mini cables Specifications Product group Fibre optic cable Type CTMC Optical fibre standard Product dependent Colour outer sheath Black Fibre type Single mode 9/5 Type of tube Loose tube, gel filled Cable metal free Strain relief Material outer sheath Polypropylene Application Outside Blowable Test procedures IEC Longitudinal water blocking Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb Product dependent Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb Product dependent UV resistant Max. 0 nm 0.8 db/km Max. 550 nm 0.5 db/km Max. 65 nm 0.8 db/km 9

90 Mini cables Mini cables Central Tube Mini Cables 6 products Part number Outer diameter approx. Net weight (kg/km) radius after radius during short term (Tm) 79 x SM G.657.A (x) x SM G.657.A (x) x SM G.657.A (x6) x SM G.657.A (x8) x SM G.657.A µm 79 x SM G.657.A 00 µm long term (Tl) 9

91 Micro cables MUC Properties The Micro Unitube Cable (MUC) is a non-metallic, waterproof customer drop cable, consisting of low bend radius, no waterpeak G.657.A fibres, in a jelly-filled central tube, surrounded by aramid-yarns (as tensile strength elements) and protected by a smooth low-friction outersheath. This outdoor cable is thin, light in weight and flexible and can be installed with narrow bending radii, therefore very suitable for application in the access network. Installation: blowing into microducts. 5 Micro cables Specifications Product group Fibre optic cable Type MUC Optical fibre standard ITU-T G.657.A Fibre type Single mode 9/5 Type of tube Loose tube, gel filled Cable metal free Strain relief Material outer sheath Product dependent Colour outer sheath Black Application Outside Blowable Standardization EN IEC Test procedures IEC Longitudinal water blocking Installation temperature -5 / 50 C Transportation and storage temperature -5 / 70 C Operational temperature range Ta - Tb Product dependent Operational temperature range Ta - Tb -0 / 70 C Max. attenuation increase during Ta - Tb 0. db UV-protection ISO 89/ Max. 0 nm 0.6 db/km Max. 550 nm 0.5 db/km Max. 65 nm 0.5 db/km 9

92 5 Micro cables Micro cables MUC 9 products Part number Outer diameter approx. Net weight (kg/km) radius after radius during 76 x SM G.657.A x SM G.657.A x SM G.657.A x SM G.657.A x SM G.657.A x SM G.657.A x SM G.657.A x SM G.657.A x SM G.657.A short term (Tm) 9

93 Micro cables SFU Properties The Smooth Fibre Unit (SFU) consists of a bundle of low bend radius, no waterpeak G.657.A fibres, encapsuled by a dry acrylate layer and protected by a smooth, slightly ribbed polyethylene outersheath, for application in the access network. Installation: blowing into microducts of.5mm. or.0mm. (inside diameter) 5 Micro cables Specifications Product group Fibre optic cable Type SFU Optical fibre standard ITU-T G.657.A Fibre type Single mode 9/5 Type of tube Central tube Cable metal free Material outer sheath PE (polyethylene) Colour outer sheath Yellow Application Inside/outside Blowable Standardization EN IEC Test procedures IEC Installation temperature -5 / 50 C Transportation and storage temperature -0 / 50 C Operational temperature range Ta - Tb -0 / 70 C Operational temperature range Ta - Tb -0 / 70 C Max. 0 nm 0.0 db/km Max. 550 nm 0.0 db/km 95

94 5 Micro cables Micro cables SFU 5 products Part number Outer diameter approx. Net weight (kg/km) radius after radius during x SM G.657.A x SM G.657.A x SM G.657.A x SM G.657.A x SM G.657.A short term (Tm) 96

95 TECHNICAL PRODUCT INFORMATION Cable construction and colour code MDIC LSZH Indoor FO drop cable with easy fibre access. Optical fibres Longitudinal non-metallic strength members Outer sheath (LSZH) Standard colours Fibres Group Blue Yellow 97

96 TECHNICAL PRODUCT INFORMATION Cable construction and colour code MDIC LSZH (Round) Indoor cable. Optical fibres Longitudinal non-metallic strength members Outer sheath LSZH Standard colours Fibres Group Red Green Blue Yellow 5 White 6 Grey 7 Brown 8 Violet 9 Turquoise 0 Black Orange Pink 98

97 TECHNICAL PRODUCT INFORMATION Cable construction and colour code STIC Color code acc. to France Telecom Optical fibres Soft tube Strength member (waterblocking aramid yarns) Outer sheath Standard colours Fibres Group Red Blue Green Yellow 5 Violet 6 White 7 Orange 8 Grey 9 Brown 0 Black Turquoise Pink Tubes Layer Red Blue Green Yellow 99

98 TECHNICAL PRODUCT INFORMATION Cable construction and colour code Simplex Indoor cable. Optical fibres Secondarily protection Strain relief elements (Aramid) Outer sheath (LSZH) Standard colours None 00

99 TECHNICAL PRODUCT INFORMATION Cable construction and colour code Duplex Optical fibres Secondarily protection Strain relief elements (Aramid) Outer sheath (LSZH) Standard colours None 0

100 TECHNICAL PRODUCT INFORMATION Cable construction and colour code Break out Central Strength-Element (FRP) Simplex cable (printed numbers) Ripcord Outer sheath (LSZH) Standard colours None 0

101 TECHNICAL PRODUCT INFORMATION Cable construction and colour code Dist ribut ion cable Optical fibres 900 µm Secondarily protection Strain relief elements (Aramid) Outer sheath (LSZH) Standard colours Fibres Group Group Red Red +t Green Green +t Blue 5 Blue +t Yellow 6 Yellow +t 5 White 7 White +t 6 Grey 8 Grey +t 7 Brown 9 Brown +t 8 Violet 0 Violet +t 9 Turquoise Turquoise +t 0 Black Natural Orange Orange +t Pink Pink +t note +t: indicates a black tracer 0

102 TECHNICAL PRODUCT INFORMATION Cable construction and colour code STAC Color code acc. to France Telecom Optical fibres Soft tube Strength member (waterblocking aramid yarns) Ripcord Inner sheath Strength member (waterblocking aramid yarns) Outer sheath Standard colours Fibres Group Red Blue Green Yellow 5 Violet 6 White 7 Orange 8 Grey 9 Brown 0 Black Turquoise Pink Tubes Layer Red Blue Green Yellow 0

103 TECHNICAL PRODUCT INFORMATION STAC Catenary Calculations Installation Temperature 5 C NESC Light NESC Medium - C Temperature -0 C 6.5 m/s Wind velocity 7.7 m/s 0 mm Ice thickness 6.5 mm Max. Sag (%) ,00 Based on the following conditions Nominal Sag % The STAC cables are suitable for the NESC-situations with spans, tensions and sags as listed in the table below. Fibre Count Tubes & Fibres x x x 6 x 6 x Temperature Wind velocity Ice thickness Max. Span Max. Tension n x m (m) (kn) x x 6 x NESC Heavy Temperature -0 C Wind velocity 7.7 m/s Ice thickness.5 mm Max. Max. Max. Max. Max. Span Tension Sag Span Tension (m) (kn) (%) (m) (kn),0 5 66, , , 5 69, , , ,68 x , , ,7 Table: Operational conditions, max. achievable span, tension and sag. Max. Sag (%) According to NF C -0A (* Temperature -5 C, ice thickness of 5mm and wind speed 80km/h) the STAC cables are suitable for maximum spans as listed in the table below Fibre count 6 Tubes Span Installation (5 C) Maximum conditions* & nom sag nom tension vect. sag Max tension Fibres n x m m % N % N x 80,0 05, x 50,0 90,60 50 x 60,0 95, x 80,0 05, x 6 50,0 90,60 50 x 50,0 90,60 50 x 6 60,0 95, x 60,0 95, x 6 55,0 00,

104 TECHNICAL PRODUCT INFORMATION Cable construction and colour code CTC ADSS FO cable with central tube. Outdoor application. Aerial fibre-optic drop cable. Optical fibres Central tube, gel-filled Reinforcement of aramid yarns Outer sheath (PE) Standard colours Fibres Group Red Green Blue Yellow 5 White 6 Grey 7 Brown 8 Violet 9 0 Turquoise Black Orange Pink 06

105 TECHNICAL PRODUCT INFORMATION CTC ADSS Catenary Calculations Fibre count Installation Tension Installed Sag Max. Span Max. Tension Tm Max. Sag Cable & Fibre Strain NESC-Light NESC-Medium NESC-Heavy max. 8 max. 8 max. 8 8 N 77 N N 58 N 0 N 8 N % % % % % % 0 m 00 m 57 m 5 m m m 50 N 50 N 50 N 50 N 50 N 50 N.7%.5%.0%.9%.%.% 0.50% 0.8% 0.9% 0.7% 0.8% 0.6% Fibre count max. 8 max. 8 max. 8 Installation Tension 67 N 86 N N 8 N 7 N 8 N Installed Sag % % % % % % Max. Span m 0 m 6 m 6 m 6 m m Max. Tension Tm 50 N 50 N 50 N 50 N 50 N 50 N Max. Sag.%.%.6%.5%.6%.5% Cable & Fibre Strain 0.50% 0.8% 0.9% 0.8% 0.8% 0.6% Fibre count max. 8 max. 8 max. 8 Installation Tension 0 N 0 N 98 N Installed Sag % % N 5 N 6 N % % % % Max. Span 9 m 7 m 7 m 69 m 0 m 8 m Max. Tension Tm 50 N 50 N 50 N 50 N Cable & Fibre Strain 0.50% 0.8% 0.9% 0.7% 50 N 50 N Max. Sag 5.0%.9% 5.% 5.% 5.% 5.% 0.8% 0.6% Wind velocity Ice thickness Additional load Temperature Units m/s km/h mps mm inch kg/m lbs/ft ºC NESC-Light NESC-Medium NESC-Heavy ºF

106 TECHNICAL PRODUCT INFORMATION Cable construction and colour code LTC ADSS 0 All-dielectric self-supporting cable. FO cable with stranded loose tubes Centre element, FRP Optical fibres Sub units &5 Binders & Waterblocking tape Waterblocking Aramide Ripcord Outer sheath Standard colours Fibres Group Red Green Blue Yellow 5 White 6 Grey 7 Brown 8 Violet 9 Turquoise 0 Black Orange Pink Tubes Layer Red Green Blue Yellow 5 White 6 Grey 7 Brown 8 Violet 9 Orange 0 Black Pink Turquoise 08

107 TECHNICAL PRODUCT INFORMATION LTC ADSS 0 Catenary Calculations based on the following conditions Installation Temperature 5 C Nominal Sag % The cables are suitable for the NESC-situations with spans, tensions and sags as listed in the table below. Fibre Count Tubes & Fibres NESC Light NESC Medium NESC Heavy Temperature - C Temperature -0 C Temperature -0 C Wind velocity 6.5 m/s Wind velocity 7.7 m/s Wind velocity 7.7 m/s Ice thickness 0 mm Ice thickness 6.5 mm Ice thickness.5 mm Span n x m (m) (N) x x Max. Max. Tension x x x x x 6 8 x 7 6 x x Max. Sag (%) Max. Max. Max. Max. Max. Span Tension Sag Span Tension Max. Sag (m) (N) (%) (m) (N) (%) x Table: Operational conditions, max. achievable span, tension and sag. 09

108 TECHNICAL PRODUCT INFORMATION Cable construction and colour code LTC ADSS / -80 / -50 All-dielectric self-supporting cable. FO cable with stranded loose tubes Centre element, FRP Optical fibres Sub units (,, 6, 8, or fibres) &5 Binders & Waterblocking tape 6 Waterblocking Aramide 7 Ripcord 8 Outer sheath Standard colours Fibres Tubes Group Group Layer Layer Red Red +t Red Red Green Green +t Green Green Blue 5 Blue +t Blue Blue Yellow 6 Yellow +t Yellow Yellow 5 White 7 White +t 5 White 5 White 6 Grey 8 Grey +t 6 Grey 6 Grey 7 Brown 9 Brown +t 7 Brown 7 Brown 8 Violet 0 Violet +t 8 Violet 8 Violet 9 Turquoise Turquoise +t 9 Orange 9 Orange 0 Black Natural 0 Black 0 Black Orange Orange +t Pink Pink Pink Pink +t Turquoise Turquoise note +t: indicates a black tracer 0

109 TECHNICAL PRODUCT INFORMATION LTC ADSS 80 Catenary Calculations Installation Temperature Nominal Sag % The cables are suitable for the NESC-situations with spans, tensions and sags as listed in the table below. Fibre Count 6 8 Tubes & Fibres NESC Light NESC Medium NESC Heavy Temperature - C Temperature -0 C Temperature -0 C Wind velocity 6.5 m/s Wind velocity 7.7 m/s Wind velocity 7.7 m/s Ice thickness 0 mm Ice thickness 6.5 mm Ice thickness.5 mm Max. Span Max. 5 C Tension n x m (m) (kn) 6 x x x x x x 8 x 8 x 7 6 x x 70.5 x x Max. Sag (%) Max. Max. Max. Max. Max. Span Based on the following conditions Tension Span Tension x 9 x Table: Operational conditions, max. achievable span, tension and sag. Sag 5. Max. Sag (m) (kn) (%) (m) (kn) (%)

110 TECHNICAL PRODUCT INFORMATION LTC ADSS 50 Catenary Calculations A. NESC - tables Wind velocity Ice thickness Additional load Temperature Units Light Medium Heavy m/s km/h mph mm inch kg/m lbs/ft ºC ºF B. NESC Light Fibre Tubes Max. Installation Operation NESC Light Count & Span Nom. Nom. Nom. Vect. Max. Max. Fibres Sag Tension CS Sag Tension CS n x m (m) (%) (N) (%) (%) (N) (%) 6x x x x x x x x x x C. NESC Medium Fibre Tubes Max. Installation Operation NESC Medium Count & Span Nom. Nom. Nom. Vect. Max. Max. Fibres Sag Tension CS Sag Tension CS n x m (m) (%) (N) (%) (%) (N) 6x x x x x x x x x x (%)

111 TECHNICAL PRODUCT INFORMATION LTC ADSS 50 Catenary Calculations D. NESC Heavy Fibre Tubes Max. Installation Operation NESC Heavy Count & Span Nom. Nom. Nom. Vect. Max. Max. Fibres Sag Tension CS Sag Tension CS n x m (m) (%) (N) (%) (%) (N) (%) 6x x x x x x x x x x

112 TECHNICAL PRODUCT INFORMATION Cable construction and colour code LTC ADSS 50 FO cable with stranded loose tubes Centre element, FRP Loose tube with optical fibres Water blocking yarns or tape Swellable tape Ripcord Inner PE sheath Water blocking Aramide Outer sheath Standard colours Fibres Tubes Group Group Layer Layer Red Red +t Red Red Green Green +t Green Green Blue 5 Blue +t Blue Blue Yellow 6 Yellow +t Yellow Yellow 5 White 7 White +t 5 White 5 White 6 Grey 8 Grey +t 6 Grey 6 Grey 7 Brown 9 Brown +t 7 Brown 7 Brown 8 Violet 0 Violet +t 8 Violet 8 Violet 9 Turquoise Turquoise +t 9 Orange 9 Orange 0 Black Natural 0 Black 0 Black Orange Orange +t Pink Pink Pink Pink +t Turquoise Turquoise note +t: indicates a black tracer

113 TECHNICAL PRODUCT INFORMATION LTC ADSS 50 Catenary Calculations A. NESC - tables Wind velocity Ice thickness Additional load Temperature Units Light Medium Heavy m/s km/h mph mm inch kg/m lbs/ft ºC ºF B. NESC Light Fibre Tubes Max. Installation Operation NESC Light Count & Span Nom. Nom. Nom. Vect. Max. Max. Fibres Sag Tension CS Sag Tension CS n x m (m) (%) (N) (%) (%) (N) (%) 6x x x x x x x x x x C. NESC Medium Fibre Tubes Max. Installation Operation NESC Medium Count & Span Nom. Nom. Nom. Vect. Max. Max. Fibres Sag Tension CS Sag Tension CS n x m (m) (%) (N) (%) (%) (N) 6x x x x x x x x x x (%) 5

114 TECHNICAL PRODUCT INFORMATION LTC ADSS 50 Catenary Calculations D. NESC Heavy Fibre Tubes Max. Installation Operation NESC Heavy Count & Span Nom. Nom. Nom. Vect. Max. Max. Fibres Sag Tension CS Sag Tension CS n x m (m) (%) (N) (%) (%) (N) (%) 6x x x x x x x x x x

115 TECHNICAL PRODUCT INFORMATION Cable construction and colour code DAC FO cable with central tube. Embedded strength members. PP outer sheath. 5 5 Optical fibres Central Tube Reinforcement Rigid Elements Polypropylene outer sheath Standard colours Fibres Group Group Red Red +t Green Green +t Blue 5 Blue +t Yellow 6 Yellow +t 5 White 7 White +t 6 Grey 8 Grey +t 7 Brown 9 Brown +t 8 Violet 0 Violet +t 9 Turquoise Turquoise +t 0 Black Natural Orange Orange +t Pink Pink +t note +t: indicates a black tracer 7

116 TECHNICAL PRODUCT INFORMATION Cable construction and colour code CTC FO cable with central tube. Optical fibres Central tube with,, 6, 8,, 6 or fibres Reinforcement of glass yarns Outer sheath (PE) Standard colours Fibres Group Group Red Red +t Green Green +t Blue 5 Blue +t Yellow 6 Yellow +t 5 White 7 White +t 6 Grey 8 Grey +t 7 Brown 9 Brown +t 8 Violet 0 Violet +t 9 Turquoise Turquoise +t 0 Black Natural Orange Orange +t Pink Pink +t note +t: indicates a black tracer 8

117 TECHNICAL PRODUCT INFORMATION Cable construction and colour code LTC-S FO cable with stranded loose tubes Centre element, FRP optional with over sheath Loose tube with optical fibres (,, 6, 8, or fibres per tube) Water blocking yarns or tape Filler Water blocking tape Ripcord (optional) Outer sheath (PE) Standard colours Fibres Tubes Group Group Layer Layer Layer Red Red +t Red Red Red Green Green +t Green Green Green Blue 5 Blue +t Blue Blue Blue Yellow 6 Yellow +t Yellow Yellow Yellow 5 White 7 White +t 5 White 5 White 5 White 6 Grey 8 Grey +t 6 Grey 6 Grey 6 Grey 7 Brown 9 Brown +t 7 Brown 7 Brown 7 Brown 8 Violet 0 Violet +t 8 Violet 8 Violet 8 Violet 9 Turquoise Turquoise +t 9 Orange 9 Orange 9 Orange 0 Black Natural 0 Black 0 Black 0 Black Orange Orange +t Pink Pink Pink Pink Pink +t Turquoise Turquoise Turquoise Red Red note +t: indicates a black tracer Green Green 5 Blue 5 Blue 6 Yellow 6 Yellow 9

118 TECHNICAL PRODUCT INFORMATION Cable construction and colour code LTC FO cable with stranded loose tubes Centre element, FRP optional with over sheath Loose tube with optical fibres (,, 6, 8, or fibres per tube) Water blocking yarns or tape Filler Water blocking tape Ripcord (optional) Outer sheath (PE) Standard colours Fibres Tubes Group Group Layer Layer Layer Red Red +t Red Red Red Green Green +t Green Green Green Blue 5 Blue +t Blue Blue Blue Yellow 6 Yellow +t Yellow Yellow Yellow 5 White 7 White +t 5 White 5 White 5 White 6 Grey 8 Grey +t 6 Grey 6 Grey 6 Grey 7 Brown 9 Brown +t 7 Brown 7 Brown 7 Brown 8 Violet 0 Violet +t 8 Violet 8 Violet 8 Violet 9 Turquoise Turquoise +t 9 Orange 9 Orange 9 Orange 0 Black Natural 0 Black 0 Black 0 Black Orange Orange +t Pink Pink Pink Pink Pink +t Turquoise Turquoise Turquoise Red Red note +t: indicates a black tracer Green Green 5 Blue 5 Blue 6 Yellow 6 Yellow 0

119 TECHNICAL PRODUCT INFORMATION Cable construction and colour code LTC RP FO cable with stranded loose tubes. Rodent Protection Centre element, FRP optional with over sheath Loose tube with optical fibres (,, 6, 8, or fibres per tube) Water blocking yarns or tape Filler Water blocking tape Glass yarn strength members (Rodent Protection) Ripcord (optional) Outer sheath (PE) Standard colours Fibres Tubes Group Group Layer Layer Layer Red Red +t Red Red Green Green +t Green Green Green Blue 5 Blue +t Blue Blue Blue Yellow 6 Yellow +t Yellow Yellow Yellow 5 White 7 White +t 5 White 5 White 5 White 6 Grey 8 Grey +t 6 Grey 6 Grey 6 Grey 7 Brown 9 Brown +t 7 Brown 7 Brown 7 Brown 8 Violet 0 Violet +t 8 Violet 8 Violet 8 9 Turquoise Turquoise +t 9 Orange 9 Orange 9 Orange 0 Black Natural 0 Black 0 Black 0 Black Orange Orange +t Pink Pink Pink Pink Pink +t Turquoise Turquoise Turquoise note +t: indicates a black tracer Red Green 5 Blue 5 6 Yellow 6 Red Violet Red Green Blue Yellow

120 TECHNICAL PRODUCT INFORMATION Cable construction and colour code LTC PA FO cable with stranded loose tubes. PE Sheath with PA skin Centre element, FRP optional with over sheath Loose tube with optical fibres (,, 6, 8, or fibres per tube) Water blocking yarns or tape Filler Water blocking tape Ripcord (optional) Inner sheath (PE) Outer sheath (PA skin) Standard colours Fibres Tubes Group Group Layer Layer Layer Red Red +t Red Red Green Green +t Green Green Green Blue 5 Blue +t Blue Blue Blue Yellow 6 Yellow +t Yellow Yellow Yellow 5 White 7 White +t 5 White 5 White 5 White 6 Grey 8 Grey +t 6 Grey 6 Grey 6 Grey 7 Brown 9 Brown +t 7 Brown 7 Brown 7 Brown 8 Violet 0 Violet +t 8 Violet 8 Violet 8 9 Turquoise Turquoise +t 9 Orange 9 Orange 9 Orange 0 Black Natural 0 Black 0 Black 0 Black Orange Orange +t Pink Pink Pink Pink Pink +t Turquoise Turquoise Turquoise note +t: indicates a black tracer Red Green 5 Blue 5 6 Yellow 6 Red Violet Red Green Blue Yellow

121 TECHNICAL PRODUCT INFORMATION Cable construction and colour code LTC-S RP FO cable with stranded loose tubes. Rodent protection Centre element, FRP optional with over sheath Loose tube with optical fibres (,, 6, 8, or fibres per tube) Water blocking yarns or tape Filler Water blocking tape Glass yarn strength members (Rodent Protection) Ripcord (optional) Outer sheath (PE) Standard colours Fibres Tubes Group Group Layer Red Red +t Red Green Green +t Green Blue 5 Blue +t Blue Yellow 6 Yellow +t Yellow 5 White 7 White +t 5 White 6 Grey 8 Grey +t 6 Grey 7 Brown 9 Brown +t 7 Brown 8 Violet 0 Violet +t 8 Violet 9 Turquoise Turquoise +t 9 Orange 0 Black Natural 0 Black Orange Orange +t Pink Pink Pink +t Turquoise note +t: indicates a black tracer

122 TECHNICAL PRODUCT INFORMATION Cable construction and colour code DAC MT FO cable with central tube. Embedded strength members. PP outer sheath Optical fibres Central Tube Reinforcement Rigid Elements Steel-wire Polypropylene outer sheath Standard colours Fibres Group Red Green Blue Yellow 5 White 6 Grey 7 Brown 8 Violet 9 Turquoise 0 Black Orange Pink

123 TECHNICAL PRODUCT INFORMATION Cable construction and colour code CTC CS FO cable with central tube. Corrugated steel tape protection Optical fibres Central tube with,, 6, 8,, 6 or fibres Reinforcement of glass yarns Inner sheath (PE) (Optional) Ripcord Rodent protection Outer sheath (PE) Standard colours Fibres Group Group Red Red +t Green Green +t Blue 5 Blue +t Yellow 6 Yellow +t 5 White 7 White +t 6 Grey 8 Grey +t 7 Brown 9 Brown +t 8 Violet 0 Violet +t 9 Turquoise Turquoise +t 0 Black Natural Orange Orange +t Pink Pink +t note +t: indicates a black tracer 5

124 TECHNICAL PRODUCT INFORMATION Cable construction and colour code LTC CS FO cable with stranded loose tubes. Corrugated Steel protection Centre element, FRP optional with over sheath Loose tube with optical fibres (,, 6, 8, or fibres per tube) Water blocking yarns or tape (optional jelly filling) Filler Water blocking tape (optional jelly filling) Glass yarn strength members (optional) Ripcord (optional) Inner sheath (PE) (optional) Corrugated steel Outer sheath (HDPE) Standard colours Fibres Tubes Group Group Layer Layer Layer Red Red +t Red Red Red Green Green +t Green Green Green Blue 5 Blue +t Blue Blue Blue Yellow 6 Yellow +t Yellow Yellow Yellow 5 White 7 White +t 5 White 5 White 5 White 6 Grey 8 Grey +t 6 Grey 6 Grey 6 Grey 7 Brown 9 Brown +t 7 Brown 7 Brown 7 Brown 8 Violet 0 Violet +t 8 Violet 8 Violet 8 Violet 9 Turquoise Turquoise +t 9 Orange 9 Orange 9 Orange 0 Black Natural 0 Black 0 Black 0 Black Orange Orange +t Pink Pink Pink Pink Pink +t Turquoise Turquoise Turquoise note +t: indicates a black tracer Red Red Green Green 5 Blue 5 Blue 6 Yellow 6 Yellow

125 TECHNICAL PRODUCT INFORMATION Cable construction and colour code LTC JF MT SWA Centre element, FRP Loose tube with optical fibres Jelly filling Aluminium tape Ripcord Inner PE sheath Steel wire armouring Outer sheath Standard colours Fibres Group Red Green Blue Yellow 5 White 6 Grey 7 Brown 8 Violet 9 Turquoise 0 Black Orange Pink Tubes Layer Red Green Blue Yellow 5 White 6 Grey 7 Brown 8 Violet 7

126 TECHNICAL PRODUCT INFORMATION Cable construction and colour code MADC Mini Aerial Drop Cable. Optical fibres Water blocking aramid yarns Outer sheath (LSZH) Standard colours Fibres Group Red Green Blue Yellow 5 White 6 Grey 7 Brown 8 Violet 9 Turquoise 0 Black Orange Pink 8

127 TECHNICAL PRODUCT INFORMATION MADC Catenary Calculations A. NESC - tables Units m/s Wind velocity km/h mph Ice thickness mm inch Temperature ºC ºF Light Medium Heavy B. NESC Light # fibres Span Installation Nom. Sag Nom. Tension (m) % (N) NESC Light Vect. Sag Max. Tension (%) (N) C. NESC Medium # fibres Span Installation Nom. Sag Nom. Tension (m) % (N) NESC Light Vect. Sag Max. Tension (%) (N). 7 D. NESC Heavy # fibres Span Installation NESC Light Nom. Nom. Sag Tension Vect. Max. Sag (m) % (N) (%) Tension (N) 75 9

128 TECHNICAL PRODUCT INFORMATION Cable construction and colour code D-DAC LSZH Optical fibres Swelling yarn Buffer tube Reinforcement Rigid Elements Outer sheath Standard colours Fibres Group Red Green Blue Yellow 5 White 6 Grey 7 Brown 8 Violet 9 Turquoise 0 Black Orange Pink 0

129 TECHNICAL PRODUCT INFORMATION Cable construction and colour code CTC LSZH FO cable with central tube. Indoor/Outdoor application. Optical fibres Central tube with,, 6, 8,, 6 or fibres Reinforcement of glass yarns Outer sheath (LSZH) Standard colours Fibres Group Group Red Red +t Green Green +t Blue 5 Blue +t Yellow 6 Yellow +t 5 White 7 White +t 6 Grey 8 Grey +t 7 Brown 9 Brown +t 8 Violet 0 Violet +t 9 Turquoise Turquoise +t 0 Black Natural Orange Orange +t Pink Pink +t note +t: indicates a black tracer

130 TECHNICAL PRODUCT INFORMATION Cable construction and colour code LTC-S LSZH FO cable with stranded loose tubes. Indoor / Outdoor application Centre element, FRP optional with over sheath Loose tube with optical fibres (,, 6, 8, or fibres per tube) Water blocking yarns or tape Filler Water blocking tape Ripcord Outer sheath (LSZH) Standard colours Fibres Tubes Group Group Layer Red Red +t Red Green Green +t Green Blue 5 Blue +t Blue Yellow 6 Yellow +t Yellow 5 White 7 White +t 5 White 6 Grey 8 Grey +t 6 Grey 7 Brown 9 Brown +t 7 Brown 8 Violet 0 Violet +t 8 Violet 9 Turquoise Turquoise +t 9 Orange 0 Black Natural 0 Black Orange Orange +t Pink Pink Pink +t Turquoise note +t: indicates a black tracer

131 TECHNICAL PRODUCT INFORMATION Cable construction and colour code LTC-S RP LSZH FO cable with stranded loose tubes. FO cable with stranded loose tubes Centre element, FRP optional with over sheath Loose tube with optical fibres (,, 6, 8, or fibres per tube) Water blocking yarns or tape Filler Water blocking tape Glass yarn strength members (Rodent Protection) Ripcord (optional) Outer sheath (LSZH) Standard colours Fibres Tubes Group Group Layer Red Red +t Red Green Green +t Green Blue 5 Blue +t Blue Yellow 6 Yellow +t Yellow 5 White 7 White +t 5 White 6 Grey 8 Grey +t 6 Grey 7 Brown 9 Brown +t 7 Brown 8 Violet 0 Violet +t 8 Violet 9 Turquoise Turquoise +t 9 Orange 0 Black Natural 0 Black Orange Orange +t Pink Pink Pink +t Turquoise note +t: indicates a black tracer

132 TECHNICAL PRODUCT INFORMATION Cable construction and colour code CTC HFFR Fire resistant FO cable with central tube. Optical fibres Central tube with,, 6, 8,, 6 or fibres Reinforcement of glass yarns Outer sheath Standard colours Fibres Group Group Red Red +t Green Green +t Blue 5 Blue +t Yellow 6 Yellow +t 5 White 7 White +t 6 Grey 8 Grey +t 7 Brown 9 Brown +t 8 Violet 0 Violet +t 9 Turquoise Turquoise +t 0 Black Natural Orange Orange +t Pink Pink +t note +t: indicates a black tracer

133 TECHNICAL PRODUCT INFORMATION Cable construction and colour code LTC-S HFFR FO cable with stranded loose tubes Centre element, FRP optional with over sheath Loose tube with optical fibres Water blocking yarns or tape Water blocking tape Glass yarn strength members (rodent protection) Ripcord Outer sheath Standard colours Fibres Group Red Green Blue Yellow 5 White 6 Grey 7 Brown 8 Violet 9 Turquoise 0 Black Orange Pink Tubes Layer Red Green Blue Yellow 5 White 6 Grey 7 Brown 8 Violet 9 Orange 0 Black Pink Turquoise 5

134 TECHNICAL PRODUCT INFORMATION Cable construction and colour code CTC CS LSZH FO cable with central tube. Corrugated steel tape protection Optical fibres Central tube with fibres Reinforcement of waterblocking glass yarns Ripcord (x) Inner sheath Corrugated steel tape Outer sheath Standard colours Fibres Group Group Red Red +t Green Green +t Blue 5 Blue +t Yellow 6 Yellow +t 5 White 7 White +t 6 Grey 8 Grey +t 7 Brown 9 Brown +t 8 Violet 0 Violet +t 9 Turquoise Turquoise +t 0 Black Natural Orange Orange +t Pink Pink +t note +t: indicates a black tracer 6

135 TECHNICAL PRODUCT INFORMATION Cable construction and colour code LTC CS LSZH FO cable with stranded loose tubes. Corrugated Steel protection Centre element, FRP optional with over sheath Loose tube with optical fibres Water blocking yarns or tape Filler Water blocking tape Reinforcement of waterblocking glass yarns (optional) Ripcord Inner sheath (LSZH (Optional) Corrugated steel tape Outer sheath (LSZH) Standard colours Fibres Tubes Group Group Layer Layer Layer Red Red +t Red Red Red Green Green +t Green Green Green Blue 5 Blue +t Blue Blue Blue Yellow 6 Yellow +t Yellow Yellow Yellow 5 White 7 White +t 5 White 5 White 5 White 6 Grey 8 Grey +t 6 Grey 6 Grey 6 Grey 7 Brown 9 Brown +t 7 Brown 7 Brown 7 Brown 8 Violet 0 Violet +t 8 Violet 8 Violet 8 Violet 9 Turquoise Turquoise +t 9 Orange 9 Orange 9 Orange 0 Black Natural 0 Black 0 Black 0 Black Orange Orange +t Pink Pink Pink Pink Pink +t Turquoise Turquoise Turquoise note +t: indicates a black tracer Red Red Green Green 5 Blue 5 Blue 6 Yellow 6 Yellow 7

136 TECHNICAL PRODUCT INFORMATION Cable construction and colour code CTC CS HFFR FO cable with central tube. Corrugated steel tape protection Optical fibres Central tube with optical fibres Reinforcement of waterblocking glass yarns Inner sheath Ripcord (x) Corrugated steel tape Outer sheath Standard colours Fibres Group Group Red Red +t Green Green +t Blue 5 Blue +t Yellow 6 Yellow +t 5 White 7 White +t 6 Grey 8 Grey +t 7 Brown 9 Brown +t 8 Violet 0 Violet +t 9 Turquoise Turquoise +t 0 Black Natural Orange Orange +t Pink Pink +t note +t: indicates a black tracer 8

137 TECHNICAL PRODUCT INFORMATION Cable construction and colour code LTC-S CS HFFR FO cable with stranded loose tubes. Corrugated steel protection Centre element, FRP optional with over sheath Loose tube with optical fibres Water blocking yarns or tape Water blocking tape Waterblocking glass yarn strength members Inner sheath Ripcord Corrugated steel Outer sheath Standard colours Fibres Group Red Green Blue Yellow 5 White 6 Grey 7 Brown 8 Violet 9 Turquoise 0 Black Orange Pink Tubes Layer Red Green Blue Yellow 5 White 6 Grey 7 Brown 8 Violet 9 Orange 0 Black Pink Turquoise 9

138 TECHNICAL PRODUCT INFORMATION Cable construction and colour code CTC CS FR FO cable with central tube. Corrugated steel tape protection Optical fibres Central tube with fibres Fire protective coating Reinforcement of waterblocking glass yarns Inner sheath Ripcord Corrugated steel tape Outer sheath Standard colours Fibres Group Group Red Red +t Green Green +t Blue 5 Blue +t Yellow 6 Yellow +t 5 White 7 White +t 6 Grey 8 Grey +t 7 Brown 9 Brown +t 8 Violet 0 Violet +t 9 Turquoise Turquoise +t 0 Black Natural Orange Orange +t Pink Pink +t note +t: indicates a black tracer 0

139 TECHNICAL PRODUCT INFORMATION Cable construction and colour code LTMC FO mini-cable with stranded mini loose tubes Centre element FRP optional with over sheath Loose tube with optical fibres ( or fibres per tube) Water blocking layer Filler (only for constructions with 5 tubes or less (< 60 fibres) Cross-binder Ripcord Outer sheath (PE) Standard colours Fibres Tubes Group Group Layer Red Red +t Red Green Green +t Green Blue 5 Blue +t Blue Yellow 6 Yellow +t Yellow 5 White 7 White +t 5 White 6 Grey 8 Grey +t 6 Grey 7 Brown 9 Brown +t 7 Brown 8 Violet 0 Violet +t 8 Violet 9 Turquoise Turquoise +t 9 Orange 0 Black Natural 0 Black Orange Orange +t Pink Pink Pink +t Turquoise note +t: indicates a black tracer

140 TECHNICAL PRODUCT INFORMATION Cable construction and colour code LTMC PA FO mini-cable with stranded mini loose tubes Centre element FRP optional with over sheath Loose tube with optical fibres ( or fibres per tube) Water blocking layer Filler (only for constructions with 5 tubes or less (< 60 fibres) Cross-binder Ripcord Outer sheath (PA) Standard colours Fibres Tubes Group Group Layer Red Red +t Red Green Green +t Green Blue 5 Blue +t Blue Yellow 6 Yellow +t Yellow 5 White 7 White +t 5 White 6 Grey 8 Grey +t 6 Grey 7 Brown 9 Brown +t 7 Brown 8 Violet 0 Violet +t 8 Violet 9 Turquoise Turquoise +t 9 Orange 0 Black Natural 0 Black Orange Orange +t Pink Pink Pink +t Turquoise note +t: indicates a black tracer

141 TECHNICAL PRODUCT INFORMATION Cable construction and colour code CTMC FO mini cable with central tube. Optical fibres Central tube with, 6, 8,, fibres Reinforcement of aramide yarns Outer sheath (PP) Standard colours Fibres Group Group Red Red +t Green Green +t Blue 5 Blue +t Yellow 6 Yellow +t 5 White 7 White +t 6 Grey 8 Grey +t 7 Brown 9 Brown +t 8 Violet 0 Violet +t 9 Turquoise Turquoise +t 0 Black Natural Orange Orange +t Pink Pink +t note +t: indicates a black tracer

142 TECHNICAL PRODUCT INFORMATION Cable construction and colour code MUC Micro unitube cable. 5 5 Optical fibres Jelly-filling Central tube Reinforcement of armide yarns Outer sheath Standard colours Fibres Group Group Red Red +t Green Green +t Blue 5 Blue +t Yellow 6 Yellow +t 5 White 7 White +t 6 Grey 8 Grey +t 7 Brown 9 Brown +t 8 Violet 0 Violet +t 9 Orange Orange +t 0 Black Natural Pink Pink +t Turquoise Turquoise +t note +t: indicates a black tracer

143 TECHNICAL PRODUCT INFORMATION Cable construction and colour code SFU Smooth Fibre Unit. Optical Fibres Inner layer (Acrylate) Outer sheath (PE) Standard colours Fibres Group Red Green Blue Yellow 5 White 6 Grey 7 Brown 8 Violet 9 Turquoise 0 Black Orange Pink 5

144 TECHNICAL PRODUCT INFORMATION Fibre Type offibre Standard Standard Product Characteristics - Optical fibres Hydrogen passivated, dispersion unshifted, matched cladding. Bending loss insensitive singlemode fibre 9/5µm. Fully compatible with G.65.D fibre. Optical and geometrical properties exceed ITU recommendations G.65.D and G.657.A IEC , B6-a ITU-T G.657.A Characteristics: Properties Unit Mode field diameter; 0 nm 9.0 ± 0. µm M ode field diameter; 550 nm 0. ± 0. µm Core non-circularity max. 6 % C ore/cladding concentricity error max. 0. µm Cladding diameter 5.0 ± 0.5 µm Cladding non-circularity max. 0.6 % Coating diameter ±5 µm Coating/Cladding concentricity error max. 8 µm Temperature sensitivity; -60 C to +85 C max db/km Bending sensitivity-0 turn around Ø0 mm nm max. 0. db Bending sensitivity-0 turn around Ø0 mm - 65 nm max. 0. db Bending sensitivity- turn around Ø0 mm nm max db Bending sensitivity- turn around Ø0 mm - 65 nm max..5 db Proof test level min Gpa Fibre curl min. m Cable cut-off wavelength max. 60 nm Zero-dispersion wavelength 00 - nm Zero-dispersion slope max ps/nm².km Chromatic dispersion; 85 nm - 0 nm max.. ps/nm.km Chromatic dispersion; 550 nm max. 7 ps/nm.km Chromatic dispersion; 65 nm max. ps/nm.km Polarisation mode dispersion; maximum individual fibre max. 0. ps/ km PMDq max ps/ km Max. attenuation at 8 nm (α 8 ) [note a] <max. α 0 Effective Group Core Refractive Index; 0 nm.67 Effective Group Core Refractive Index; 550 nm.675 Effective Group Core Refractive Index; 65 nm.680 note a: after hydrogen ageing 6

145 TECHNICAL PRODUCT INFORMATION Fibre Product Characteristics - Optical fibres Type offibre Hydrogen passivated, dispersion unshifted, matched cladding bending loss insensitive singlemode fibre 9/5µm. Fully compatible with G.65.D fibre. Reduced coating diameter Standard ITU-T G.657.A Characteristics: Properties Unit Mode field diameter; 0 nm 9.0 ± 0. µm M ode field diameter; 550 nm 0. ± 0. µm Core non-circularity max. 6 % C ore/cladding concentricity error max. 0.5 µm Cladding diameter 5.0 ± 0.5 µm Cladding non-circularity max. 0.8 % Coating diameter 98 ±6 µm Coating/Cladding concentricity error max. 8 µm Temperature sensitivity; -60 C to +85 C max db/km Bending sensitivity-00 turns around Ø50 mm nm max db Bending sensitivity-00 turns around Ø60 mm - 65 nm max db Bending sensitivity-0 turn around Ø0 mm nm max. 0.5 db Bending sensitivity-0 turn around Ø0 mm - 65 nm max..0 db Bending sensitivity- turn around Ø0 mm nm max db Bending sensitivity- turn around Ø0 mm - 65 nm max..5 db Proof test level min Gpa Fibre curl min. m Cable cut-off wavelength max. 60 nm Zero-dispersion wavelength 00 - nm Zero-dispersion slope max ps/nm².km Chromatic dispersion; 85 nm - 0 nm max.. ps/nm.km Chromatic dispersion; 550 nm max. 7 ps/nm.km Chromatic dispersion; 65 nm max. ps/nm.km Polarisation mode dispersion; maximum individual fibre max. 0. ps/ km PMDq max ps/ km Max. attenuation at 8 nm (α 8 ) [note a] <max. α 0 Effective Group Core Refractive Index; 0 nm.67 Effective Group Core Refractive Index; 550 nm.675 Effective Group Core Refractive Index; 65 nm.680 note a: after hydrogen ageing 7

146 TECHNICAL PRODUCT INFORMATION Fibre Type offibre Standard Standard Product Characteristics - Optical fibres Hydrogen passivated, dispersion unshifted, matched cladding bending loss insensitive singlemode fibre 9/5µm. Fully compatible with G.65.D fibre. Optical and geometrical properties exceed ITU- recommendations G.65.D and G.657.A IEC , B6-a ITU-T G.657.A Characteristics: Properties Unit Mode field diameter; 0 nm 8.7 ± 0. µm M ode field diameter; 550 nm 9.9 ± 0.5 µm C ore/cladding concentricity error max. 0.5 µm C ladding diameter 5.0 ± 0.5 µm Cladding non-circularity max. 0.7 % Coating diameter ±5 µm Coating/Cladding concentricity error max. 8 µm Temperature sensitivity; -60 C to +85 C max db/km Bending sensitivity-0 turns around Ø0 mm nm max. 0.0 db Bending sensitivity-0 turns around Ø0 mm - 65 nm max. 0. db Bending sensitivity- turn around Ø0 mm nm max. 0. db Bending sensitivity- turn around Ø0 mm - 65 nm max. 0. db Bending sensitivity- turn around Ø5 mm nm max. 0.5 db Bending sensitivity- turn around Ø5 mm - 65 nm max..0 db Proof test level min Gpa Fibre curl min. m Cable cut-off wavelength max. 60 nm Zero-dispersion wavelength 00 - nm Zero-dispersion slope max ps/nm².km Chromatic dispersion; 550 nm max. 8 ps/nm.km Chromatic dispersion; 65 nm max. ps/nm.km Polarisation mode dispersion; maximum individual fibre max. 0. ps/ km PMDq max ps/ km Max. attenuation at 8 nm (α 8 ) [note a] <max. α 0 Effective Group Core Refractive Index; 0 nm.676 Effective Group Core Refractive Index; 550 nm.68 Effective Group Core Refractive Index; 65 nm.685 note a: after hydrogen ageing 8

147 TELECOM SOLUTIONS If you need assistance or want to request a quote, please contact our sales team: Telecom headquarters Tel. + (0) Fax + (0) info@ace-fibreoptic.com Telecom France Tel. + (0)6 5 8 Fax + (0)6 5 8 info@ace-fibreoptic.com Telecom Germany Tel. +9 (0) Fax +9 (0)8 660 info-de@tkf.eu info@ace-fibreoptic.com Telecom Finland, Estonia, Latvia & Lithuania Tel Fax + (0) Tel. + (0) info@ace-fibreoptic.com Telecom Sweden Tel. +6 (0)5 00 Tel. + (0) TKF Telecom Services Tel. + (0) Service line + (0) Fax + (0) Fax + (0) info@ace-fibreoptic.com telecomservices@tkf.eu 9

148 CABLE DRUM SIZES AND WEIGHTS A wide range of drums with various sizes and weights is used to store and transport our cables. The most common types of drums and their sizes and weights are shown in this table. Flange diameter (F) mm Core diameter (K) mm Central hole diameter (A) mm Largest width (B) mm Empty drum return To get your empty drums in the Netherlands collected quickly, please send your request to our shipping department via the website ( or by to haspels@tkf.nl. If drums have to be collected outside the Netherlands, please contact our sales staff. Winding width (W) mm Empty weight Kg Volume m³ * ,5 0,7 * , , * , , , , , , , , , , , , ,0 * Plastic drum F = Diameter flange K = Diameter core A = Diameter axle-hole B = Largest width W = Winding width 50

149 MORE INFORMATION This catalogue contains information about product families. Information at item level can be requested via our website and from our sales staff. This catalogue has been customized. Information about products that are not included in this catalogue is available from our sales departments and can also be found on our website Please contact us for additional technical or commercial information. Contact information of our sales teams can be found on our website. Subject to changes TKF reserves the right to make changes to its product specifications and its range of products without informing clients of this in advance. Disclaimer This catalogue is put together with great care. Nevertheless we can t give any guarantees regarding the completeness, correctness or actualization of the information in this catalogue. No rights can be derived from the information as shown in this catalogue. TKF is entitled to modify this catalogue at all times with immediate effect due to (for example) changes in legislation. TKF can t be held responsible for the content of this catalogue or the consequences of using the information including incorrect translation of the information by third parties. TKF All rights reserved. Information in this catalogue may only be distributed with acknowledgement of the source. Terms of delivery Our general terms of delivery apply to all our deliveries including the products named in the catalogue. They are available via our website or from our sales departments. 5

150 TKF Finland TKF Sweden TKF Headquarters C&C Partners TKF GmbH TKF SAS 5 Copyright TKF No rights can be derived from this information.

151

152 Spinnerstraat 5 P.O. Box 6 NL-780 AA Haaksbergen The Netherlands Telephone: + (0) info@tkf.eu info@ace-fibreoptic.com Internet: Copyright TKF Version 0-07

HELKAMA. Optical Fibre Cables

HELKAMA. Optical Fibre Cables 1 Contents Optical fibres and their characteristics Cable constructions Cable tests Installation, jointing and terminating Manufacturing (pictures) 2 Multimode Fibre (GK) Attenuation and Bandwidth Fibre

More information

GUCN. Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection v13.

GUCN. Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection v13. GUCN Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection 07-07-05 v3.0 Ordering Information Belden Part Numbers Fibre Description

More information

GCRG. Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection v7.0. Ordering Information.

GCRG. Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection v7.0. Ordering Information. GCRG Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection 05-05-7 v7.0 Ordering Information Belden Part Numbers Fibre Description / count 4 8 8 4 30 36 6.5/5-OM GCRG04

More information

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK PART 1 GENERAL 1.01 SCOPE OF WORK SECTION 27 12 23 FIBER OPTIC DATA NETWORK A. Furnish, install, terminate, and test all fiber optic equipment and cabling necessary for a complete and functional data highway

More information

outdoor and indoor campus backbone, building backbone (riser) FDDI, Gigabit Ethernet and ATM Easy to install direct burial halogen-free

outdoor and indoor campus backbone, building backbone (riser) FDDI, Gigabit Ethernet and ATM Easy to install direct burial halogen-free GUSN Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection 05-04-8 v0.0 Ordering Information Belden Part Numbers Fibre Description / count 4 6 8 6 4

More information

Easy to install in ducts, tunnels and trenches by means of compressed air or pulling wire. Suitable for direct burial (crush 400 N/cm).

Easy to install in ducts, tunnels and trenches by means of compressed air or pulling wire. Suitable for direct burial (crush 400 N/cm). GCDG Multi Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)H(SR)H Full Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count

More information

Fibre Optic Cable. Catalogue.

Fibre Optic Cable. Catalogue. Fibre Optic Cable Catalogue www.fibrefab.com About The FibreFab Group FibreFab Established in 1992, FibreFab is a leading provider of fibre optic connectivity products used in data communications and Telecommunication

More information

Duct Cable GYTS-144B1.3

Duct Cable GYTS-144B1.3 Optical Fibre Cable Technical Specification Duct Cable GYTS-144B1.3 Xcom Ltd All rights reserved 1. Scope This Specification covers the design requirements and performance standard for the supply of optical

More information

Ø 1000 * 588 mm 50 kg

Ø 1000 * 588 mm 50 kg GUCN Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count

More information

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1 Page 1/9 Illustrations Principle diagram See enlarged drawings at the end of document Product specification connection cable I-V(ZN)HH breakout cable for direct connector termination for indoors and outdoors

More information

Multipurpose Cables (indoor/outdoor), Multipurpose central tube cable (maxibundle) with glass yarn armouring A-DQ(BN)H 4-24

Multipurpose Cables (indoor/outdoor), Multipurpose central tube cable (maxibundle) with glass yarn armouring A-DQ(BN)H 4-24 Features and Benefits Laminated swelling glass yarns Improved rodent resistance and longitudinal water protection UV and microbe resistant Can be directly buried or installed in ducts Metal-free cable

More information

GBRD. Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection. Ordering Information. Applications. Features & Benefits

GBRD. Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection. Ordering Information. Applications. Features & Benefits GBRD Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count 24 36 48 60 72 62.5/125-OM1 GBRD124 GBRD136 GBRD148 GBRD160

More information

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers Features and Benefits Corrugated armor Mechanical protection Low-smoke/zero-halogen (LSZH ) sheath Key life-safety benefit Meets cyclic impact and chemical resistance test Superior performance Tray-rated

More information

OPTICAL. Micromodule DW About Us. > IEC nd Ed. According to. > EN nd Ed. FTTx

OPTICAL. Micromodule DW About Us. > IEC nd Ed. According to. > EN nd Ed. FTTx fibrewave About Us Prysmian is a global market leader in optical cables, supplying a major part of the world s optical cable needs. With a strong heritage of highly advanced R&D, Prysmian is at the leading

More information

Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive

Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive Illustrations Principle diagram Page 1/7 Product specification installation cable U-DQ(ZN)BH universal fiber optic cable for indoors/outdoors with central or stranded loose tube bend insensitive fiber

More information

Data sheet OpDAT mini breakout cable 24x1 OM4 - bend insensitive

Data sheet OpDAT mini breakout cable 24x1 OM4 - bend insensitive Page 1/8 Illustrations Principle diagram See enlarged drawings at the end of document Product specification mini-breakout installation cable U-VQ(ZN)H laser-optimized, bend insensitive fiber UV-resistant,

More information

Special Provision No. 683S28 December 2017

Special Provision No. 683S28 December 2017 FIBRE OPTIC COMMUNICATION CABLES, AERIAL ON MESSENGER CABLE - Item No. FIBRE OPTIC COMMUNICATION CABLES, AERIAL ON MESSENGER CABLE (TEMPORARY) - Item No. Special Provision No. 683S28 December 2017 1. SCOPE

More information

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red OFC-UT-CST Fire resistant Armoured Indoor/Outdoor steel tape armoured (CST) double LSHF-FR sheathed optical cable with 2 24 fibres. VDE: A/I-DQ(ZN)H(SR)H 3rd party verification of the fire tests by BUREAU

More information

GUSA. Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection. Ordering Information.

GUSA. Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection. Ordering Information. GUSA Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count 2 4 6 8 12 62.5/125-OM1

More information

GUSN. Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection. Ordering Information.

GUSN. Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection. Ordering Information. GUSN Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count 2 4 6 8 12 16 24 62.5/125-OM1

More information

Optical Fibre Cable Technical Specification. Duct Cable GYTA-72B1.3

Optical Fibre Cable Technical Specification. Duct Cable GYTA-72B1.3 VersionGYTA-72B1.3 Optical Fibre Cable Technical Specification Duct Cable GYTA-72B1.3 Yangtze Optical Fibre and Cable Joint Stock Limited Company All rights reserved www.yofc.com All Rights Reserved Copyright

More information

13-SDMS-02 REV. 00 SPECIFICATIONS FOR NON-METALLIC, TIGHT BUFFERED & RETRACTABLE, MICRO FIBER OPTIC CABLE FOR INTERNAL INSTALLATION

13-SDMS-02 REV. 00 SPECIFICATIONS FOR NON-METALLIC, TIGHT BUFFERED & RETRACTABLE, MICRO FIBER OPTIC CABLE FOR INTERNAL INSTALLATION 13-SDMS-02 REV. 00 SPECIFICATIONS FOR NON-METALLIC, TIGHT BUFFERED & RETRACTABLE, MICRO FIBER OPTIC CABLE FOR INTERNAL INSTALLATION This specification is property of SEC and subject to change or modification

More information

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red Indoor/Outdoor steel tape armoured (CST) double LSHF-FR sheathed optical cable with 2 24 fibres. VDE: A/I-DQ(ZN)H(SR)H 3rd party verification of the fire tests by BUREAU VERITAS December 2014 OFC-UT-CST

More information

industry solutions: military

industry solutions: military industry solutions: military MC industry Solutions: Military A tradition of leadership in technology, product performance for military applications Optical Cable Corporation is a leading manufacturer of

More information

SPECIAL ELECTRICAL AND OPTICAL CABLES

SPECIAL ELECTRICAL AND OPTICAL CABLES SPECIAL ELECTRICAL AND OPTICAL CABLES INTRODUCTION The new high-speed trains and the sensible increase of the traffic, with congested lines, is the result of the latest development of the rail sector.

More information

FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS - Item No. FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS (TEMPORARY) - Item No.

FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS - Item No. FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS (TEMPORARY) - Item No. FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS - Item No. FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS (TEMPORARY) - Item No. Special Provision No. 683S01 December 2017 1. SCOPE This Special Provision covers

More information

Fibre optic media options and trends

Fibre optic media options and trends Fibre optic media options and trends Presented by D Stockton & P Lascelles of Miniflex Ltd, branded as m2fx 23 February 2012 1 Contents Cable constructs Indoor/outdoor LSZH Armouring Micro Bends Singlemode,

More information

Tratos Railway Cables

Tratos Railway Cables January 2013 Tratos Railway Cables Cables for a moving world www.tratos.eu Introduction Tratos Cavi is a company specialising in the production of power, signalling, control and telecommunications cables

More information

PolyOne is a global polymer solutions provider with the ability to meet regulatory and product

PolyOne is a global polymer solutions provider with the ability to meet regulatory and product Product Description PolyOne is a global polymer solutions provider with the ability to meet regulatory and product specifications globally and offer the widest range of polymer-specific specialty colorant

More information

DNVGL-CP-0402 Edition February 2016

DNVGL-CP-0402 Edition February 2016 CLASS PROGRAMME Type approval DNVGL-CP-0402 Edition February 2016 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD

More information

TE CONNECTIVITY <fiber count> <fiber type> <flame rating> MM/YY SO<shop order number> XXXXX FEET

TE CONNECTIVITY <fiber count> <fiber type> <flame rating> MM/YY SO<shop order number> XXXXX FEET Optic Backbone Distribution Cables 900um Buffered Aramid Yarn Strength Members Outer 6 or 12 Subunit Central Strength Member Outer Ripcord Single Unit Cable 6-24 Multi-Unit Cable 24-144 Description: TE

More information

The Quality Connection. BETAflam Fire Resistant Safety Cables

The Quality Connection. BETAflam Fire Resistant Safety Cables The Quality Connection BETAflam Fire Resistant Safety Cables BETAflam Contact Your personal customer number To offer you a more efficient service, we kindly ask you to mention your personal customer number

More information

TECHNICAL REPORT IEC TR Optical fibre cables Guidelines to the installation of optical fibre cables. colour inside. Edition 2.

TECHNICAL REPORT IEC TR Optical fibre cables Guidelines to the installation of optical fibre cables. colour inside. Edition 2. TECHNICAL REPORT IEC TR 62691 Edition 2.0 2016-06 colour inside Optical fibre cables Guidelines to the installation of optical fibre cables INTERNATIONAL ELECTROTECHNICAL COMMISSION ICS 33.180.10 ISBN

More information

Fiber Optic Distribution Cables (6-144 Fibers)

Fiber Optic Distribution Cables (6-144 Fibers) 900um Buffered Aramid Yarn Strength Members Outer 6 or 12 Subunit Central Strength Member Outer Ripcord Single Unit Cable 6-24 Multi-Unit Cable 24-144 Description: AMP NETCONNECT distribution cables are

More information

Main features of the JETnet system

Main features of the JETnet system Main features of the JETnet system Proven concept. The JETnet microduct system of Draka Comteq is a well-established system used on a worldwide basis by many reputable companies. JETnet continues to maintain

More information

GOF Indoor and Outdoor Cables. Documentation VWL Version 1.1 Source Code M

GOF Indoor and Outdoor Cables. Documentation VWL Version 1.1 Source Code M GOF Indoor and Outdoor Cables Documentation VWL 064.503 Version 1.1 Source Code M GOF Installation Cables Cable matrix / overview Source code M Use Indoor In- / Outdoor Outdoor Type of cable Breakout Mini-

More information

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design. ADDISON Flame Retardant RG59 B/U Coaxial cables Plain copper wire braid PE Solid Bare Copper PVC Outer Sheath APPLICATION The cables are designed for CCTV, security, smoke detection and evacuation monitoring

More information

GOF Indoor and Outdoor Cables. Documentation VWL Version 2.2 Source Code R

GOF Indoor and Outdoor Cables. Documentation VWL Version 2.2 Source Code R GOF Indoor and Outdoor Cables Documentation VWL 064.504 Version 2.2 Source Code R GOF Installation Cables Cable matrix / overview Source code: R Use Indoor In- / Outdoor Outdoor Type of cable Breakout

More information

Installation Considerations for Pipelines

Installation Considerations for Pipelines Installation Considerations for Pipelines Introduction The main uses for distributed fiber optic sensing in monitoring pipelines are: Detecting unauthorized (or unexpected) third party interference in

More information

BS /1000V XLPE Insulation LSZH Sheath Cables

BS /1000V XLPE Insulation LSZH Sheath Cables BS 8573 600/1000V XLPE Insulation LSZH Sheath Cables Caledonian www.addison-cables.com Company Profile Caledonian & Addison, branded under Caledoniea & Addimax, established in 1978, offers one of the most

More information

Caledonian Flame Retardant Coaxial Cables

Caledonian Flame Retardant Coaxial Cables Caledonian Flame Retardant Coaxial Cables www.caledonian-cables.co.uk www.addison-cables.com Flame Retardant RG59 Coaxial cables LSZH Outer Sheath Tinned Copper Braid Aluminium+polyester/Aluminium Tape

More information

Specification No.CSC-131/R-1/DH//UH/P&D/ Technical Specifications. for 24 Fiber/48 Fiber Unarmoured. Underground Fibre.

Specification No.CSC-131/R-1/DH//UH/P&D/ Technical Specifications. for 24 Fiber/48 Fiber Unarmoured. Underground Fibre. Specification No.CSC-131/R-1/DH//UH/P&D/2016-17 Technical Specifications for 24 Fiber/48 Fiber Unarmoured Underground Fibre Optic Cabling Issue Month:June-2016 (CSC Amendment date 14.06.2016) Common Specification

More information

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores)

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores) Caledonian Flame Retardant Power & Control Cables www.caledonian-s.co.uk www.addison-s.com 600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores) FTX400 1RZ1MZ1-R (CU/XLPE/LSZH/DSTA/LSZH

More information

Catalogue Telecommunication Cables INTRODUCCIÓN

Catalogue Telecommunication Cables INTRODUCCIÓN Catalogue Telecommunication Cables INTRODUCCIÓN Conductores Tecnológicos S.A. www.contecsa.es Index of Cables Page Introduction 3 EAP / EAP-R 4 EAPSP / EAPSP-R 5 ISP / ICP 6 Conductores Tecnológicos S.A.

More information

High Performance LSZH Fire Resistant Cable

High Performance LSZH Fire Resistant Cable High Performance LSZH Fire Resistant Cable www.cavicel.com 104/2 FIRECEL SR 114H is the long and well established CAVICEL fire resistant cable in the market, since many years. These cables are third party

More information

Catalogue Power Cables

Catalogue Power Cables Catalogue Power Cables Conductores Tecnológicos S.A. www.contecsa.es Index of Cables Page Introduction 13 RV 14 RVMV 15 RVSV 16 RVFV 17 Conductores Tecnológicos S.A. 2 www.contecsa.es INTRODUCTION Power

More information

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore)

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore) 600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore) FGD400 1RV-R (CU/XLPE/PVC 600/1000V Class ) FGD400 1RVMV-R (CU/XLPE/PVC/SWA/PVC 600/1000V Class ) PVC Outer Sheath Plain Annealed

More information

speed pipe indoor system. Secure indoor networks.

speed pipe indoor system. Secure indoor networks. speed pipe indoor system. Secure indoor networks. www.gabocom.com gabo Systemtechnik 2 3 Networks of the future. Safety obliges. Fiber-optic more and more approaches the end-user also inside buildings

More information

Communication Solutions for Energy Generation, Transmission and Distribution

Communication Solutions for Energy Generation, Transmission and Distribution Energy Communication Solutions for Energy Generation, Transmission and Distribution AFL offers an extensive range of products suitable for use in energy projects across the globe. These include: Wind

More information

ITU-T L.63. Safety practice for outdoor installations

ITU-T L.63. Safety practice for outdoor installations International Telecommunication Union ITU-T L.63 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (10/2004) SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

More information

Connectors for Optic Fibre Cable

Connectors for Optic Fibre Cable Connectors for Optic Fibre Cable Direct Buried Connectors and End Caps Push-In Fittings 6270 Page 1-75 6270..03 Page 1-75 6273 Page 1-75 6273..03 Page 1-75 Direct Install Connectors and End Caps 6271 Page

More information

Sumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber. PureGuide SM Optical Fiber, TIA Type IVd. Issued: November 2003

Sumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber. PureGuide SM Optical Fiber, TIA Type IVd. Issued: November 2003 Sumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber PureGuide SM Optical Fiber, TIA Type IVd Issued: November 2003 78 Alexander Drive, Research Triangle Park, NC 27709 Phone

More information

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES INDEX Corflex MC-HL Instrumentation - Pairs and Triads (0V*)... 1 - CORFLEX Cables

More information

PRODUCT CATALOGUE Norröna

PRODUCT CATALOGUE  Norröna PRODUCT CATALOGUE Norröna WWW.SCANKAB.COM Table of contents MARINE AND OFFSHORE CABLES 1 TOXFREE XZ1-K (AS) - 0.6/1 kv 1 TOXFREE MARINE XO2TCuZ1-K (AS) - 150/250 V 5 4x2xAWG 24/1 CAT6 S/FTP LSZH-SHF1 -

More information

Fiber Optic Patch Cord and Pigtails

Fiber Optic Patch Cord and Pigtails Fiber Optic Patch Cord and Pigtails Description The optical fiber patch cords are fitted at both ends with same connector types or different connector types. Our fiber optic patch cords are ultra reliable

More information

fire resistant cables

fire resistant cables Building Technology fire resistant cables Special electrical and optical cables www.tecnikabel.com Special electrical and optical cables 2 INTRODUCTION Structured cabling solutions. Tecnikabel can provide

More information

Power Cables. Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7. ELECWIRES 2 Page

Power Cables. Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7. ELECWIRES 2  Page Power Cables Power Cables Page Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7 ELECWIRES 2 www.elecwires.es INTRODUCTION Power Cables Power cables for electrical installations, domestic & industrial, specifically

More information

Flame Retardant Overall Screened Instrumentation Cables (multicore)

Flame Retardant Overall Screened Instrumentation Cables (multicore) Flame Retardant Overall Screened Instrumentation Cables (multicore) RE-2X(St)H RE-2X(St)HSWAH LSZH Outer Sheath Tinned Copper Drain Wire LSZH Inner Sheath XLPE Insulation Plain Annealed Copper Aluminium/polyester

More information

FIRE RESISTANT CABLES

FIRE RESISTANT CABLES Conducting Value The Last Cable Standing FIRE RESISTANT CABLES 100/7b ISO 9001:2008 Certificate No. CS1-249 MANAGEMENT SYSTEMS Assessed to ISO 9001:2008 Cert/LPCB ref. 217 GOST ISO 9001-2011 (ISO 9001:2008)

More information

Welcome Bucharest! New developments in Duct Solutions and Cable Deployment Techniques

Welcome Bucharest! New developments in Duct Solutions and Cable Deployment Techniques Welcome Bucharest! New developments in Duct Solutions and Cable Deployment Techniques MDU Do It Right First Time Background to EMTELLE 34 years experience in micro tube production Emtelle technology About

More information

FTTX Solutions Mini Rapid Fiber Distribution Terminal (RDT)

FTTX Solutions Mini Rapid Fiber Distribution Terminal (RDT) TE Connectivity's (TE) FTTX infrastructure solutions are designed from the ground up to meet the unique requirements of FTTX networks. Designed for operational efficiency and scalability, TE s FTTX solutions

More information

Sumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber

Sumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber Sumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber PureGuide -LA SM Optical Fiber, TIA Type IVd ITU G.655 C and D Compliant Issued:

More information

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES CORFLEX TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES INDEX Instrumentation Cables - Pairs and Triads (0V*)... 2 - The Original MC-HL Technology In 1958 Canada Wire and Cable, which s now part of Nexans,

More information

INTERIM EUROPEAN I-ETS TELECOMMUNICATION June 1997 STANDARD

INTERIM EUROPEAN I-ETS TELECOMMUNICATION June 1997 STANDARD INTERIM EUROPEAN I-ETS 300 644 TELECOMMUNICATION June 1997 STANDARD Source: ETSI TC-TM Reference: DI/TM-01021 ICS: 33.020 Key words: Fibre, cable, optical, transmission Transmission and Multiplexing (TM);

More information

Product Catalogue. External Management

Product Catalogue. External Management Product Catalogue External Management version 2017 Empowering businesses through innovative network solutions. We have been pushing boundaries and providing innovative products and solutions to clients

More information

ITU-T L.404. Field mountable single-mode optical fibre connectors

ITU-T L.404. Field mountable single-mode optical fibre connectors I n t e r n a t i o n a l T e l e c o m m u n i c a t i o n U n i o n ITU-T L.404 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (08/2017) SERIES L: ENVIRONMENT AND ICTS, CLIMATE CHANGE, E-WASTE, ENERGY

More information

Test report for a Teldor Cables SLA-6-01X08- ZAHRH-DD Fibre Optic cable to IEC :1999

Test report for a Teldor Cables SLA-6-01X08- ZAHRH-DD Fibre Optic cable to IEC :1999 Test report for a Teldor Cables SLA-6-01X08- ZAHRH-DD Fibre Optic cable to IEC 60331-25:1999 Prepared for: Teldor Cables & Systems Ltd Ein-Dor Kibbutz Ein-Dor 19335 Israel 16 March 2011 0578 Page 1 of

More information

Advancing Pipeline Safety

Advancing Pipeline Safety Advancing Pipeline Safety 2018 Western Regional Gas Conference Mark Uncapher August 2018 FOSA Director muncapher@fiberopticsensing.org FOSA_TC_INF_002-1 What is FOSA? The Fiber Optic Sensing Association

More information

NZQA unit standard version 1 Page 1 of 6. Install, maintain and repair of telecommunications optical fibre network infrastructure

NZQA unit standard version 1 Page 1 of 6. Install, maintain and repair of telecommunications optical fibre network infrastructure Page 1 of 6 Title Install, maintain and repair of telecommunications optical fibre network infrastructure Level 3 Credits 25 Purpose This unit standard covers installation, maintenance and repair of telecommunications

More information

(Notices) EUROPEAN COMMISSION

(Notices) EUROPEAN COMMISSION 14.8.2012 Official Journal of the European Union C 245/1 IV (Notices) NOTICES FROM EUROPEAN UNION INSTITUTIONS, BODIES, OFFICES AND AGENCIES EUROPEAN COMMISSION Commission communication in the framework

More information

Core identification code. J-YY...BD Indoor Cable. J-YY...BD Indoor Cable. VDE 0815 Mutual capacitance. J-YY...BD Indoor Cable. Cu conductor 0.

Core identification code. J-YY...BD Indoor Cable. J-YY...BD Indoor Cable. VDE 0815 Mutual capacitance. J-YY...BD Indoor Cable. Cu conductor 0. Indoor cables J-YY...BD Indoor J-Y(ST)Y..LG Indoor Comparable products UNITRONIC J-2Y(ST)Y...ST III BD see page 271 Indoor telephone cables transmit analogue or digital signals In news and communication

More information

FiberExpress Solutions

FiberExpress Solutions 7.2.1-A 7.2.1-B 7.2.1-C 7.2.1-D Simplex Patch Cord Duplex Patch Cord Hybrid Patch Cord Single-ended (pigtails) AX200057 Patch Cord Multimode SC Duplex DESCRIPTION FiberExpress Simplex and Duplex Patch

More information

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION Fire alarm cables for highest safety requirements TRADITION INNOVATION PASSION Datwyler Datwyler Cabling Solutions is an internationally operating company with its headquarters in Switzerland and affiliates

More information

ALEWIJNSE INTERNATIONAL SWITCHBOARD PRODUCTION

ALEWIJNSE INTERNATIONAL SWITCHBOARD PRODUCTION ALEWIJNSE INTERNATIONAL SWITCHBOARD PRODUCTION www.alewijnse.com Empowering your business INTRODUCTION A lewijnse International Switchboard Production (AISP) designs and assembles distribution switchboards,

More information

Catalogue. Instrumentation & Control Cables

Catalogue. Instrumentation & Control Cables Catalogue Instrumentation & Control Cables Conductores Tecnológicos S.A. www.contecsa.es Index of Cables Page Introduction 3 Instrumentation VOV 4 VHOV 5 VOVMV 6 VHOVMV 7 Control RV 8 RZ1C3Z1 9 Conductores

More information

Cable technology for highest safety requirements

Cable technology for highest safety requirements Cable technology for highest safety requirements Daetwyler We are a provider of high-grade quality system solutions and services in the areas of structured data cabling, telecom carriers, safety cabling,

More information

WG Buried Fibre Cable Long Perimeter Detection System

WG Buried Fibre Cable Long Perimeter Detection System WI CODE : 11954 Telephone : +44 (01295 756300 Fax : +44 (0)1295 756302 E-Mail : info@wi-ltd.com Website : www.wi-ltd.com WG Buried Fibre Cable Long Perimeter Detection System The WG Buried Cable Long Perimeter

More information

Fiber Optic and CAT 5, 6, 7 and 8 Installer Premise Cabling

Fiber Optic and CAT 5, 6, 7 and 8 Installer Premise Cabling Hands-On Fiber Optic and CAT 5, 6, 7 and 8 Installer Premise Cabling Certification Course Description This Hands-On course is customized to give Technicians the confidence and skills to maintain Fiber

More information

LV FIRE RESISTANT CABLES

LV FIRE RESISTANT CABLES LV FIRE RESISTANT CABLES CONTENTS 3 GENERAL INTRODUCTION LV FIRE RESISTANT CABLES TECHNICAL INFORMATION 4 9 12 24 26 GENERAL CABLE STRUCTURE ELECTRICAL CHARACTERISTICS CURRENT RATING VOLTAGE DROP SHORT

More information

Caledonian Fire resistant Coaxial Cables

Caledonian Fire resistant Coaxial Cables Caledonian Fire resistant Coaxial Cables www.caledonian-cables.net www.addison-cables.com Fire resistant rg59 b/u Coaxial Cables RG59 B/U FR LSZH Sheath Fire Resistant Tape Copper Clad Steel/Bare Copper

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60794-1-21 Edition 1.0 2015-03 colour inside Optical fibre cables Part 1-21: Generic specification Basic optical cable test procedures Mechanical test methods INTERNATIONAL ELECTROTECHNICAL

More information

Telecommunication Cables

Telecommunication Cables Telecommunication Cables Telecommunication Cables Introduction 3 EAP / EAP-R 4 EAPSP / EAPSP-R 5 ISP / ICP 6 Page ELECWIRES 2 www.elecwires.es INTRODUCCIÓN Telecommunication Cables Telephone cables suitable

More information

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour. 67 POWERFLEX RV-K POWERFLEX RV-K Industrial flexible cable for power transmission. 1 IEC 60502-1 - UNE 21123-2 DESIGN 1. Conductor 2 Electrolytic copper, class 5 (flexible), based on EN 60228 and IEC 60228.

More information

Well Services Group. Best in Class BEST IN CLASS

Well Services Group. Best in Class BEST IN CLASS Best in Class The and its service lines operate globally and provide a full range of high-quality, capital-intensive services to the international oil and gas industry, the petrochemical and geothermal

More information

Comtran Cable. Hub-LINK Cables for Transit Applications

Comtran Cable. Hub-LINK Cables for Transit Applications Comtran Cable Hub-LINK Cables for Transit Applications Overview Hub-LINK rail transit cables are designed to resist the rugged conditions of the underground and at-grade environments, including: Temperature

More information

CORRIGENDA. (Publication of titles and references of harmonised standards under Union harmonisation legislation)

CORRIGENDA. (Publication of titles and references of harmonised standards under Union harmonisation legislation) C 173/162 EN Official Journal of the European Union 13.5.2016 CORRIGENDA Corrigendum to Commission communication in the framework of the implementation of Directive 2006/95/EC of the European Parliament

More information

MT-RJ Optical Fiber System Field Testing

MT-RJ Optical Fiber System Field Testing MT-RJ Optical Fiber System Field Testing Table of Contents INTRODUCTION... 3 TEST JUMPERS... 4 LAUNCH CONDITIONS... 4 MT-RJ TEST KITS... 5 MT-RJ SYSTEM TESTING: Fixed transmit and receive (SC or ST-style)

More information

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2017/C 298/02)

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2017/C 298/02) C 298/14 EN Official Journal of the European Union 8.9.2017 Commission communication in the framework of the implementation of Directive 2014/35/EU of the European Parliament and of the Council on the

More information

SAFE CABLING SYSTEMS IN TUNNELS UNDER FIRE

SAFE CABLING SYSTEMS IN TUNNELS UNDER FIRE - 249 - SAFE CABLING SYSTEMS IN TUNNELS UNDER FIRE Urs Welte Amstein + Walthert AG, Switzerland ABSTRACT The paper aims at a detailed analysis of the current know-how in the construction of tunnel cabling

More information

Copper Connectivity Products

Copper Connectivity Products Outside Plant Solutions Copper Connectivity Products IDC Encapsulated Discrete Connectors 8 Series Connectors Excellent insulation resistance and electrical performance Accepts wire 0.4 to 0.9mm (26 to

More information

Corra/Clad MC Cable The contractors cable of choice in place of conduit and wire.

Corra/Clad MC Cable The contractors cable of choice in place of conduit and wire. Corra/Clad MC Cable The contractors cable of choice in place of conduit and wire. Installs fast and easy Lowers labor costs Replaces conduit and wire Provides superior grounding UL Listed Corra/Clad MC

More information

Cables and cabling solutions for residential buildings: safety, comfort and environmental-friendliness

Cables and cabling solutions for residential buildings: safety, comfort and environmental-friendliness Cables and cabling solutions for residential buildings: safety, comfort and environmental-friendliness Turning a domicile into a super home While offering you a wide range of for residences of all kinds

More information

Lloyd s Register Type Approval System Test Specification Number 3

Lloyd s Register Type Approval System Test Specification Number 3 Working together for a safer world Lloyd s Register Type Approval System Test Specification Number 3 July 2015 Performance Test Specification for Equipment to be used in Marine Applications: Electric Cables

More information

CONTENTS. Introduction Customer Service BS codes of practice BS Fire Performance Cable Selection Guide... 7

CONTENTS. Introduction Customer Service BS codes of practice BS Fire Performance Cable Selection Guide... 7 CONTENTS Page Introduction... 1 Customer Service... 2 BS codes of practice BS 8519... 5 Fire Performance Cable Selection Guide... 7 FlamBICC Introduction...8 FlamBICC 1...10 FlamBICC 2...12 FlamBICC 3...14

More information

OFFSHORE CABLES. Top Cable Central Headquarters. Leonardo Da Vinci, number Rubí (Barcelona) Spain

OFFSHORE CABLES.   Top Cable Central Headquarters. Leonardo Da Vinci, number Rubí (Barcelona) Spain Top Cable Central Headquarters Leonardo Da Vinci, number 1 08191 Rubí (Barcelona) Spain OFFSHORE CABLES Tel +4 9 586 21 78 +4 9 586 21 68 Fax +4 9 586 21 65 sales@topcableoffshoremarine.com http://www.topcableoffshoremarine.com

More information

Outdoor Enclosures. Outdoor Enclosures Protected like a bunker for all harsh environments

Outdoor Enclosures. Outdoor Enclosures Protected like a bunker for all harsh environments Outdoor Enclosures Outdoor Enclosures Protected like a bunker for all harsh environments sales@mcldatasolutions.co.uk +44(0)1702 443810 mcldatasolutions.co.uk Outdoor enclosures and climate control components

More information

Table of Contents. TELE-FONIKA KABLE SA (DMCC Branch). 4 TELE-FONIKA Kable Group 6 FLAME-X 950 SERIES 1 11 FLAME-X 950 SERIES 2

Table of Contents. TELE-FONIKA KABLE SA (DMCC Branch). 4 TELE-FONIKA Kable Group 6 FLAME-X 950 SERIES 1 11 FLAME-X 950 SERIES 2 FLAME-X 950 TELE-FONIKA KABLE SA (DMCC Branch). Table of Contents is the Regional Middle East Sales Office of Tele-Fonika Kable S.A. from Poland, 4-th largest manufacturer of electric cables and wires

More information

Multi-Core Fire Resistant Cable

Multi-Core Fire Resistant Cable Fire Resistant Cables / Multi-Core Fire Resistant Cable Approved to UL 444, Zeta ZFP series cables have received UL approval for standard applications. Standards Alarm Cable Z UL 444 Approval CMH Rated

More information

Reinforced FBG Sensors Serve Demanding Applications

Reinforced FBG Sensors Serve Demanding Applications Reinforced FBG Sensors Serve Demanding Applications Kevin Hsu, Andrei Csipkes, and Tommy Jin Technica Optical Components / 3657 Peachtree Rd, Suite 10A, Atlanta, 30319, USA, info@technicasa.com, www.technicasa.com

More information

CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag

CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag STANDARD COLOR CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag TECHNICAL DATA SHEET Revision Number. 1 Last Edited 9. januar 2019 OTHER COLORS MATERIAL Flat band cross linked polyolefin. OPERATING

More information