Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

Size: px
Start display at page:

Download "Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation."

Transcription

1 Technical Data Sheet BETAflam Solar 125 flex UL 4703 Description Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation. Approvals TÜV Rheinland 2 PfG PV1-F Nr. R CSA C 22.2 No report No , CU UL / PV Wire, UL 854 USE , NEC NFPA A Application Applicable as photovoltaic wire for modules and connection to the inverter of grounded and ungrounded photovoltaic power systems. The high quality insulation components are offering UV and ozone protection at 90 C for more than 25 years. 1. STUDERCABLES.COM SWITZERLAND BETAFLAM SOLAR 125 FLEX UL Construction 1. Conductor tinned fine copper strands according to VDE 0295/ IEC 60228, Cl Insulation white electron-beam cross-linked compound, flame retardant, halogen free 3. Jacket black electron-beam cross-linked compound, flame retardant, halogen free, UV and ozone resistant Dimensions Construction Article - Conductor Cond.-Ø Cable-Ø Resistance Weight Fire load Nr. Max. [n x mm²] [n x mm] [mm] [mm] mω/m [kg/km] [kwh/m] 1x AWG x / x 4 12 AWG x / x 6 10 AWG x / x 10 8 AWG x / Other dimensions upon request. Dated: /KEW Leoni Studer AG Ae- Date: Ae-Index: 05 Datei: BETAflam Solar 125 flex UL 4703_E_Ae_05 Page 1 / 2

2 Technical Data Sheet BETAflam Solar 125 flex UL 4703 Labelling Cross Section STUDERCABLES.COM SWITZERLAND BETAFLAM SOLAR 125 FLEX UL /1000 VAC 1 X MM2 TÜV PV1-F / E USE-2 / E PV WIRE AWG 90C WET OR DRY 600V SUN RES -40C (UL) RPV XL (ctuvus) AWG NR... Production Lot Number for internal purpose only. Subject to modifications. Technical Data Nominal voltage Test voltage U 0 /U 600 / 1000 V AC ; 1000 / 1800 V DC 6500 V AC 50Hz Temperature rating (20 000h) - 40 C up to C Ambient temperature > 25 years - 40 C up to + 90 C Max. short circuit temperature Min. bending radius 280 C, +536 F fixed installation 4 x Ø occasionally moved > 5 x Ø Material properties / Standards Design / Dimensions TÜV 2 PfG PV1-F, CSA C 22.2 No UL / PV WIRE, UL 854 USE-2 Halogen free IEC No corrosive gases IEC Flame retardant IEC / UL / VW1 Low smoke emission IEC 61034; EN Low fire load DIN No hazardous and toxic substances Ozone resistant EU-Directive: RoHS 2002/95/EC; PAH 2005/69/EC; PFOS 2006/122/EC EN h/40 C, process B Volume concentration 200x10-6 Material properties and technical data are subject to modifications. Dated: /KEW Leoni Studer AG Ae- Date: Ae-Index: 05 Datei: BETAflam Solar 125 flex UL 4703_E_Ae_05 Page 2 / 2

3 Technical informations 25 Standard packaging / Technical information Current rating 120 C / 248 F Ambient temperature 30 C / 86 F Construction Exposed On surfaces without opposite contact On surfaces with opposite contact In conduit, casing, duct 1 1 mm2 A A A A Continuous duty with current loads as per above table. This gives a conductor temperature of 120 C. (Calculation according IEC 60287) Conversion factors for deviating ambient temperatures (basis 30 C) Temperature Current rating at 120 C C Factor

4 BETAflam Solar 16 Module connection cables BETAflam Solar 125 RV flex FRNC Photovoltaic power cables, halogen free, flame retardant Advantages BETAflam Solar 125 RV flex FRNC Applications Double insulated, electron-beam cross-linked cables for photovoltaic power applications. With reduced diameter and integrated jacket. Construction Conductor Insulation Jacket Jacket colour Electrical characteristics Rated value Test voltage Tinned fine copper strands, acc. to VDE 0295 / IEC 60228, Class 5 XLPO, flame retardant, halogen free, electron-beam cross-linked XLPO, flame retardant, halogen free, electron-beam cross-linked, UV and ozone resistant black U 0 /U = 600 / 1000 V AC, 1000 / 1800 V DC 6500 V, 50 Hz, 5 min. Thermal characteristics Operating temperature Ambient temperature > 25 years (TÜV) Max. short circuit temp. 40 C up to +125 C 40 F up to +257 F 40 C up to +90 C 40 F up to +194 F 280 C, +536 F, 5 s Bending radius <10 mm >10 mm Fixed installation Occasionally moved Standards / Material properties > 4 > 5 > 5 > 7 Fire performance: IEC , IEC Smoke emission: IEC 61034; EN Low fire load: DIN Approvals: TÜV 2 PfG PV1-F Application standards: UNE 21123; UNE , UTE C Electron-beam cross-linked compounds UV, ozone and hydrolysis resistant High temperature resistance, the materials do not melt or flow Very long service life > 25 years at 90 C Compatible to all popular connectors Flexible and space-saving installation

5 BETAflam Solar 125 RV flex FRNC Module connection cables 17 BETAflam Solar Dimensions, weights Construction Marking Conductor Outer Resistance Weight Fire load Order no. n mm2 Colour mm mm max, mω/m kg/km kwh/m white white white white white white white white red red red Order units Construction Marking Order no. n mm2 Farbe m m m m m 1 4 white V V V2 1 6 white V V V white V2 1 4 red V V2 1 6 red V V3 More information on the standard packaging unit see page 26. Further packaging units upon request. Bold printed order no. = stock item

The Quality Connection. BETAflam Solar Photovoltaic power cables

The Quality Connection. BETAflam Solar Photovoltaic power cables The Quality Connection BETAflam Solar Photovoltaic power cables 2 We connect technology, efficiency & ecological awareness already today. BETAflam Solar Clean cables for clean energy. Whether it is an

More information

Photovoltaic Cables EN H1Z2Z2-K

Photovoltaic Cables EN H1Z2Z2-K Photovoltaic Cables EN 50618 H1Z2Z2-K COMPANY PROFILE Caledonian, established in 1978, offers one of the most complete lines of fiber and copper cabling system solutions with over hundreds of different

More information

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V PHOTOVOLTAIC CABLES PHOTOVOLTAIC CABLES INDEX n AmerSol Dual-Certified (UL / ETL) Photovoltaic Cable 2000V/1500V....................... 2-3 n AmerSol Dual-Certified (UL / ETL) Photovoltaic Cable 2000V/1000V.......................

More information

The Quality Connection. BETAflam Fire Resistant Safety Cables

The Quality Connection. BETAflam Fire Resistant Safety Cables The Quality Connection BETAflam Fire Resistant Safety Cables BETAflam Contact Your personal customer number To offer you a more efficient service, we kindly ask you to mention your personal customer number

More information

Traction Cable Radox 3 GKW

Traction Cable Radox 3 GKW General Properties : Excellent high temperature, low temperature, ozone and weathering resistance, zero halogen, flame retardant, solder iron resistant, easily strippable, flexible. Application : Single

More information

The Quality Connection. BETAflam safety cables for highest demands

The Quality Connection. BETAflam safety cables for highest demands The Quality Connection BETAflam safety cables for highest demands 2 For solutions that will still be standard tomorrow. BETAflam safety cables Thanks to their proven quality, BETAflam safety cables are

More information

Single core cables with reduced wall thickness

Single core cables with reduced wall thickness Product description: RADOX 4 GKW -AX 1800V M Nominal voltage: Hazard level: Single core cables with reduced wall thickness 1800 / 3000 V AC M (extra low temperature, extra oil and extra fuel resistant)

More information

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores) 600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores) FFX400 1SZ1-R(PH60)(CU/SR/LSZH 600/1000V Class 2) FFX400 1SZ1-F(PH60)(CU/SR/LSZH 600/1000V Class 5) Silicone Rubber Insulation Plain

More information

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores)

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores) Caledonian Flame Retardant Power & Control Cables www.caledonian-s.co.uk www.addison-s.com 600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores) FTX400 1RZ1MZ1-R (CU/XLPE/LSZH/DSTA/LSZH

More information

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore)

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore) 600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore) FGD400 1RV-R (CU/XLPE/PVC 600/1000V Class ) FGD400 1RVMV-R (CU/XLPE/PVC/SWA/PVC 600/1000V Class ) PVC Outer Sheath Plain Annealed

More information

The Quality Connection. BETAflam Safety cables for highest demands

The Quality Connection. BETAflam Safety cables for highest demands The Quality Connection BETAflam Safety cables for highest demands 2 For solutions that will still be standard tomorrow. BETAflam Safety cables Thanks to their proven quality, BETAflam safety cables are

More information

Caledonian Flame Retardant Coaxial Cables

Caledonian Flame Retardant Coaxial Cables Caledonian Flame Retardant Coaxial Cables www.caledonian-cables.co.uk www.addison-cables.com Flame Retardant RG59 Coaxial cables LSZH Outer Sheath Tinned Copper Braid Aluminium+polyester/Aluminium Tape

More information

PRODUCT CATALOGUE Norröna

PRODUCT CATALOGUE  Norröna PRODUCT CATALOGUE Norröna WWW.SCANKAB.COM Table of contents MARINE AND OFFSHORE CABLES 1 TOXFREE XZ1-K (AS) - 0.6/1 kv 1 TOXFREE MARINE XO2TCuZ1-K (AS) - 150/250 V 5 4x2xAWG 24/1 CAT6 S/FTP LSZH-SHF1 -

More information

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+) Page 1 / 7 Construction and tests. Standards: UNE 211025 Compliance with the Low Voltage Directive (LVD): 2014/35 / EU Construction Products Regulation (CPR) - Regulation (EU) Nº 305/2011: Reaction to

More information

UNIKA Universal Cable Cable Specialist

UNIKA Universal Cable Cable Specialist UNIKA Universal Cable Cable Specialist Committed to Quality At ÜNİKA, quality is an intrinsic part of our Operations. Our comprehensive product and System certification not only are mandatory requirements

More information

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers Features and Benefits Corrugated armor Mechanical protection Low-smoke/zero-halogen (LSZH ) sheath Key life-safety benefit Meets cyclic impact and chemical resistance test Superior performance Tray-rated

More information

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission ADDISON Flame Retardant CAT5e Data Cables FTX-CAT5e U/UTP4P24 FTX-CAT5e f/utp4p24 FTX-CAT5e sf/utp4p24 LSZH Outer Aluminium/Polyester Tape Solid Copper Conductor PE Insulation Tinned Copper Drain Wire

More information

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION Fire alarm cables for highest safety requirements TRADITION INNOVATION PASSION Datwyler Datwyler Cabling Solutions is an internationally operating company with its headquarters in Switzerland and affiliates

More information

High Performance LSZH Fire Resistant Cable

High Performance LSZH Fire Resistant Cable High Performance LSZH Fire Resistant Cable www.cavicel.com 104/2 FIRECEL SR 114H is the long and well established CAVICEL fire resistant cable in the market, since many years. These cables are third party

More information

SOLARLOK Interconnection System Installation Manual

SOLARLOK Interconnection System Installation Manual SOLARLOK Interconnection System 1. Safety Note! n The SOLARLOK connector is to be used only to interconnect firmly fixed cables. n Do not disconnect under electrical load! n Electrical current path should

More information

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design. ADDISON Flame Retardant RG59 B/U Coaxial cables Plain copper wire braid PE Solid Bare Copper PVC Outer Sheath APPLICATION The cables are designed for CCTV, security, smoke detection and evacuation monitoring

More information

Flexible Power Cable DLO

Flexible Power Cable DLO 37-119 Flexible Power Cable DLO 2000 Volts 90 C Diesel Locomotive Cable Limited Smoke (Sizes 2/0 and higher) EP/CPE RHH, RHW-2 Flexible-stranded, tin-coated annealed copper Flame retardant, oil and sunlight

More information

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission Flame Retardant RS485 Databus Cables Copper Wire Braid(optional) Individual AL/Polyester Tape(optional) Foam PE/Foam skin PE. Stranded Tinned Copper AL/Polyester Tape With Tinned Copper Drain Wire LSZH

More information

Catalogue Power Cables

Catalogue Power Cables Catalogue Power Cables Conductores Tecnológicos S.A. www.contecsa.es Index of Cables Page Introduction 13 RV 14 RVMV 15 RVSV 16 RVFV 17 Conductores Tecnológicos S.A. 2 www.contecsa.es INTRODUCTION Power

More information

Cable technology for highest safety requirements

Cable technology for highest safety requirements Cable technology for highest safety requirements Daetwyler We are a provider of high-grade quality system solutions and services in the areas of structured data cabling, telecom carriers, safety cabling,

More information

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour. 67 POWERFLEX RV-K POWERFLEX RV-K Industrial flexible cable for power transmission. 1 IEC 60502-1 - UNE 21123-2 DESIGN 1. Conductor 2 Electrolytic copper, class 5 (flexible), based on EN 60228 and IEC 60228.

More information

Type approval qualification of Photovoltaic Modules Procedures and test experiences

Type approval qualification of Photovoltaic Modules Procedures and test experiences Type approval qualification of Photovoltaic Modules Procedures and test experiences We Advise. Develop. Facilitate. Inspect. Certificate. Precisely Right. For You. 1 Type approval qualification of Photovoltaic

More information

The Quality Connection. BETAflam Fire safety cables

The Quality Connection. BETAflam Fire safety cables The Quality Connection BETAflam Fire safety cables 2 We connect tomorrow s world already today. BETAflam Safety cables Halogen-free and environmentally friendly cables and single cores for applications

More information

Flame Retardant Overall Screened Instrumentation Cables (multicore)

Flame Retardant Overall Screened Instrumentation Cables (multicore) Flame Retardant Overall Screened Instrumentation Cables (multicore) RE-2X(St)H RE-2X(St)HSWAH LSZH Outer Sheath Tinned Copper Drain Wire LSZH Inner Sheath XLPE Insulation Plain Annealed Copper Aluminium/polyester

More information

DNVGL-CP-0401 Edition February 2016

DNVGL-CP-0401 Edition February 2016 CLASS PROGRAMME Type approval DNVGL-CP-0401 Edition February 2016 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD

More information

For Further information please visit our PSIDA DIY PVac640 fully integrated AC system

For Further information please visit our   PSIDA DIY PVac640 fully integrated AC system Ψ PSIDA Photovoltaic Systems Integrated Design and Automation. PSIDA DIY PVac640 fully integrated AC system The Sun is forever, don't you deserve the best in solar panel price and efficiency? PSIDA is

More information

For Further information please visit our PSIDA DIY PVac500 fully integrated AC system

For Further information please visit our   PSIDA DIY PVac500 fully integrated AC system Ψ PSIDA. Photovoltaic Systems Integrated Design and Automation. PSIDA DIY PVac500 fully integrated AC system The Sun is forever, don't you deserve the best in solar panel price and efficiency? PSIDA is

More information

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES CORFLEX TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES INDEX Instrumentation Cables - Pairs and Triads (0V*)... 2 - The Original MC-HL Technology In 1958 Canada Wire and Cable, which s now part of Nexans,

More information

Fire Risks and Safety Standards

Fire Risks and Safety Standards Fire Risks and Safety Standards Florian Reil TÜV Rheinland Group Renewable Energies 51105 Cologne, Germany Phone: + 49 221 806 27 94 Email: Florian.Reil@de.tuv.com Workshop BIPV The Increasing Role of

More information

Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES

Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES 37-754 FLAME RETARDANT EP/CPE TYPE TC OR TC-ER POWER CABLE Two Five Conductor + Ground (Two, Three & Four Conductor) 600 V Rated 90 C Conductor*

More information

S Low loss coax cables with foamed PE

S Low loss coax cables with foamed PE S Low loss coax cables with foamed PE Cable design Electrical cable data Impedance () 50 Capacitance 82 pf/m Velocity of signal propagation 82 % of the speed of light Epsilon r 1.5 Signal delay 4.1ns/m

More information

DNVGL-CP-0399 Edition March 2016

DNVGL-CP-0399 Edition March 2016 CLASS PROGRAMME Type approval DNVGL-CP-0399 Edition March 2016 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD

More information

Power Cables. Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7. ELECWIRES 2 Page

Power Cables. Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7. ELECWIRES 2  Page Power Cables Power Cables Page Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7 ELECWIRES 2 www.elecwires.es INTRODUCTION Power Cables Power cables for electrical installations, domestic & industrial, specifically

More information

Here Comes the Sun!!!

Here Comes the Sun!!! Technical Article Here Comes the Sun!!! Construction of solar photovoltaic (PV) power supply systems!! What calls the standard DIN VDE 0100-712 for the construction of solar photovoltaic (PV) power supply

More information

CIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES

CIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES CIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES Gexol CIR ARCTIC GRADE (AG) Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by

More information

CIR AG Power Cables. CIR AG Control Cable. CIR Type VFD Cable. CIR AG Ratings & Approvals. n UL Listed as Type TC-ER n UL Listed as TC-ER-HL (E123629)

CIR AG Power Cables. CIR AG Control Cable. CIR Type VFD Cable. CIR AG Ratings & Approvals. n UL Listed as Type TC-ER n UL Listed as TC-ER-HL (E123629) Gexol CIR ARCTIC GRADE (AG) Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL n Shortest Lead Times Standard 8-10

More information

CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES

CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES Gexol CIR Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL Index

More information

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES INDEX Corflex MC-HL Instrumentation - Pairs and Triads (0V*)... 1 - CORFLEX Cables

More information

Caledonian fire Resistant signal & Data cables

Caledonian fire Resistant signal & Data cables fire Resistant signal & Data cables www.addison-tech.com fire Resistant Rs485 Databus cables Copper Wire Braid(optional) Individual AL/Polyester Tape(optional) Mica Glass Tape+PE/PE+Silicone Rubber Insulation

More information

Caledonian Fire resistant Coaxial Cables

Caledonian Fire resistant Coaxial Cables Caledonian Fire resistant Coaxial Cables www.caledonian-cables.net www.addison-cables.com Fire resistant rg59 b/u Coaxial Cables RG59 B/U FR LSZH Sheath Fire Resistant Tape Copper Clad Steel/Bare Copper

More information

SOLAR CABLES. Electric cables for solar PV installations

SOLAR CABLES. Electric cables for solar PV installations SOLAR CABLES Electric cables for solar PV installations TOP CABLE Top Cable is an internationally recognized manufacturer of electric cables, and is highly thought of by professional Engineers & Electricians

More information

Labeling to Article 690 of the National Electrical Code Routing and Protecting PV Cables

Labeling to Article 690 of the National Electrical Code Routing and Protecting PV Cables Labeling to Article 690 of the National Electrical Code Routing and Protecting PV Cables Article 690 labeling requirements from the NEC 2011 Edition General overview of industry labeling Labeling updates

More information

Table of Contents. TELE-FONIKA KABLE SA (DMCC Branch). 4 TELE-FONIKA Kable Group 6 FLAME-X 950 SERIES 1 11 FLAME-X 950 SERIES 2

Table of Contents. TELE-FONIKA KABLE SA (DMCC Branch). 4 TELE-FONIKA Kable Group 6 FLAME-X 950 SERIES 1 11 FLAME-X 950 SERIES 2 FLAME-X 950 TELE-FONIKA KABLE SA (DMCC Branch). Table of Contents is the Regional Middle East Sales Office of Tele-Fonika Kable S.A. from Poland, 4-th largest manufacturer of electric cables and wires

More information

Brand Portable Power Cord & Control Cable Solutions

Brand Portable Power Cord & Control Cable Solutions Carol Brand Portable Power Cord & Control Cable Solutions for the Entertainment Market General Cable s Carol Brand portable power cord and control cable solutions are manufactured for use in the entertainment

More information

Overmoulded Cable Assembly Selector Guide

Overmoulded Cable Assembly Selector Guide CABLE ASSEMBLY Overmoulded Assembly Selector Guide Assembly SOURIAU Services An availability around the world - Global manufacturing locations - Vast network of authorised distribution partners. Reliable

More information

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded) T M 1 isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded) Technical Bulletin NAE1012372 / 03.2015 isopv

More information

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards Change History Date Description of Change Pages / Sections Modified Change Approver Initials 8/1/17 Updated section on Manufacturers 3 1. 6/15/16 Updated division section from 16120 to 26 05 00, - mgl44

More information

Compact Module. Category 6A FTP Cabling System 1.1

Compact Module. Category 6A FTP Cabling System 1.1 Updated 24/09/12 Compact Module Cat 6A performance Suitable for 10-Gigabit Ethernet Ultra-slimline design Euro style module Interchangeable with other Euro Modules and blanks Individually QA tested Easy

More information

fire resistant cables

fire resistant cables Building Technology fire resistant cables Special electrical and optical cables www.tecnikabel.com Special electrical and optical cables 2 INTRODUCTION Structured cabling solutions. Tecnikabel can provide

More information

PHOTOVOLTAIC SYSTEMS

PHOTOVOLTAIC SYSTEMS PHOTOVOLTAIC SYSTEMS EUROPEAN PERSPECTIVE Marc Van de Velde Vice President Centre of Excellence Property Risk Engineering / GAPS NFPA Conference April 2016, Munich - Germany Objectives Introduction Cells,

More information

SECTION RADIANT-HEATING ELECTRIC CABLES / MATS

SECTION RADIANT-HEATING ELECTRIC CABLES / MATS SECTION 238313- RADIANT-HEATING ELECTRIC CABLES / MATS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Electric radiant snow melting mats or cables embedded in concrete or asphalt slabs, or embedded under brick

More information

PERFORMANCE POLYMER SOLUTIONS

PERFORMANCE POLYMER SOLUTIONS PERFORMANCE POLYMER SOLUTIONS THERMODAN PEXIDAN HF PEXIDAN Advanced LSZH Thermoplastic Compounds Advanced LSZH Cross-Linkable Compounds XLPE Cross-Linkable Compounds Moisture Cure Technology SACO AEI

More information

Catalogue Telecommunication Cables INTRODUCCIÓN

Catalogue Telecommunication Cables INTRODUCCIÓN Catalogue Telecommunication Cables INTRODUCCIÓN Conductores Tecnológicos S.A. www.contecsa.es Index of Cables Page Introduction 3 EAP / EAP-R 4 EAPSP / EAPSP-R 5 ISP / ICP 6 Conductores Tecnológicos S.A.

More information

Heat Tracing Sales Mt. Airy, Maryland Heating Cable. Cut to Length in Field. Description

Heat Tracing Sales Mt. Airy, Maryland Heating Cable. Cut to Length in Field. Description Self-Regulating Protection D E C B A Self-Regulating, Energy Efficient Designed for Protection Max. Exposure Temp. 185 F (Power Off) Cost Effective for Commercial Construction Protection Applications Protection

More information

System Circuit integrity in the event of fire. Safety cables and systems from a pro. Cabling Solutions

System Circuit integrity in the event of fire. Safety cables and systems from a pro. Cabling Solutions System Circuit integrity in the event of fire and systems from a pro Cabling Solutions Safety cable systems Halogen-free safety cables with reference to VDE H05Z-K, H07Z-K / U / R 22 NHXMH, (N)HXM(St)H

More information

UV RESISTANT ACCORDING TO HD 605 RULE

UV RESISTANT ACCORDING TO HD 605 RULE UV RESISTANT ACCORDING TO HD 605 RULE Faced with increasingly frequent requirements to install outdoor wiring for data and signals, we further developed a special range of cables called: BLUE TOP LINE

More information

LSOH Flexible Cables

LSOH Flexible Cables LSOH Flexible Cables Low Voltage (300/500 V) 3182B, 3183B, 3184B Piresafe TM Flex Cable Approvals Key Applications > Supply leads for medium duty domestic and office appliances, lighting fittings and portable

More information

IDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER

IDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER IDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER Published 3/23/2012 T hough rapidly increasing in popularity, tray cables are still a point of confusion for many. While the term tray cable

More information

Multi-Core Fire Resistant Cable

Multi-Core Fire Resistant Cable Fire Resistant Cables / Multi-Core Fire Resistant Cable Approved to UL 444, Zeta ZFP series cables have received UL approval for standard applications. Standards Alarm Cable Z UL 444 Approval CMH Rated

More information

Introduction.

Introduction. Introduction The safety of occupants and users of public, commercial and industrial premises is of paramount importance. One important safety feature is the appropriate use of fire performance cables for

More information

CONNECTION SYSTEMS TRANSIT APPLICATIONS

CONNECTION SYSTEMS TRANSIT APPLICATIONS CNNECTIN SYSTEMS TRANSIT APPLICATINS Ensure electrical and mechanical reliability with the engineered products and solutions of Shawcor s Connection Systems group INTEGRITY IS BEHIND EVERYTHING WE D. By

More information

FIRE RESISTANT CABLES

FIRE RESISTANT CABLES Conducting Value The Last Cable Standing FIRE RESISTANT CABLES 100/7b ISO 9001:2008 Certificate No. CS1-249 MANAGEMENT SYSTEMS Assessed to ISO 9001:2008 Cert/LPCB ref. 217 GOST ISO 9001-2011 (ISO 9001:2008)

More information

CATALOG LIQUID-TUFF FLEXIBLE LIQUIDTIGHT CONDUIT CATALOG. Industrial & Commercial Liquidtight Conduit Flexible Metal Conduit A PART OF

CATALOG LIQUID-TUFF FLEXIBLE LIQUIDTIGHT CONDUIT CATALOG. Industrial & Commercial Liquidtight Conduit Flexible Metal Conduit A PART OF CATALOG LIQUID-TUFF FLIBL LIQUIDTIGHT CONDUIT CATALOG Industrial & Commercial Liquidtight Conduit Flexible Metal Conduit A PART OF AFC s Flexible Liquidtight Conduit AFC Cable Systems is pleased to announce

More information

outdoor and indoor campus backbone, building backbone (riser) FDDI, Gigabit Ethernet and ATM Easy to install direct burial halogen-free

outdoor and indoor campus backbone, building backbone (riser) FDDI, Gigabit Ethernet and ATM Easy to install direct burial halogen-free GUSN Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection 05-04-8 v0.0 Ordering Information Belden Part Numbers Fibre Description / count 4 6 8 6 4

More information

BS /1000V XLPE Insulation LSZH Sheath Cables

BS /1000V XLPE Insulation LSZH Sheath Cables BS 8573 600/1000V XLPE Insulation LSZH Sheath Cables Caledonian www.addison-cables.com Company Profile Caledonian & Addison, branded under Caledoniea & Addimax, established in 1978, offers one of the most

More information

Frost Protection Thermostat

Frost Protection Thermostat 1 203 Frost Protection Thermostat Electromechanical thermal reset limit thermostat RAK-TW.5..H RAK-TW.5..H.. Use Monitoring of frost protection temperature, with single-pole changeover microswitch Switching

More information

FIRST-CLASS IN TRAINS

FIRST-CLASS IN TRAINS FIRST-CLASS IN TRAINS Powered by TCPDF (www.tcpdf.org) Powered by TCPDF (www.tcpdf.org) Advanced fire protection for railway vehicles: hazard level 2 & 3 according to EN 45545 Effectively prevents moisture

More information

Thermocouple Cable TRANSMITTING, SENSING, MEASURING

Thermocouple Cable TRANSMITTING, SENSING, MEASURING Thermocouple Cable TRANSMITTING, SENSING, MEASURING Our Commitment Our commitment to our customers is simple - we deliver even when others can t. As one of Canada s largest wire, cable and data communication

More information

Energy Division Heat-shrinkable joints for halogen-free, flame-retardant and fire-resistand cables up to 1 kv

Energy Division   Heat-shrinkable joints for halogen-free, flame-retardant and fire-resistand cables up to 1 kv Energy Division http://energy.tycoelectronics.com Heat-shrinkable joints for halogen-free, flame-retardant and fire-resistand cables up to 1 kv R Heat-shrinkable joints for halogen-free, flame-retardant

More information

Core identification code. J-YY...BD Indoor Cable. J-YY...BD Indoor Cable. VDE 0815 Mutual capacitance. J-YY...BD Indoor Cable. Cu conductor 0.

Core identification code. J-YY...BD Indoor Cable. J-YY...BD Indoor Cable. VDE 0815 Mutual capacitance. J-YY...BD Indoor Cable. Cu conductor 0. Indoor cables J-YY...BD Indoor J-Y(ST)Y..LG Indoor Comparable products UNITRONIC J-2Y(ST)Y...ST III BD see page 271 Indoor telephone cables transmit analogue or digital signals In news and communication

More information

Product Information Motor and machine protection

Product Information Motor and machine protection - Basic information The REISSMANN Sensortechnik heater bands were specifically designed for the electric motor industry. These heater bands are delivered as a finished product, in various combinations,

More information

SECTION RADIANT-HEATING ELECTRIC CABLES PART 1 - GENERAL 1.1 SECTIONS INCLUDES

SECTION RADIANT-HEATING ELECTRIC CABLES PART 1 - GENERAL 1.1 SECTIONS INCLUDES SECTION 238313 - RADIANT-HEATING ELECTRIC CABLES PART 1 - GENERAL 1.1 SECTIONS INCLUDES A. Low-voltage Electric Snow and ice heating elements "under" finished roof materials (shingles or metal), gutters,

More information

FIRE RESISTANT CABLES FP300

FIRE RESISTANT CABLES FP300 FIRE RESISTANT CABLES FP300 Fire resistant LSOH power cables for fixed wiring FIRE RESISTANT CABLES FP300 LPCB Ref No: 077e/01 FP300 > Prysmian FP300 is designed for cabling essential safety circuits associated

More information

OIL & GAS INDUSTRY OTHER INDUSTRIES

OIL & GAS INDUSTRY OTHER INDUSTRIES For ATEX Areas OIL & GAS INDUSTRY OTHER INDUSTRIES OIL & GAS INDUSTRY POTENTIALLY HAZARDOUS Class I GASES VAPORS LIQUIDS Petrosumsave Zone 0 An area in which an explosive mixture is continuously present,

More information

FUMEGUARD TM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED LOW SMOKE HALOGEN FREE CABLES

FUMEGUARD TM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED LOW SMOKE HALOGEN FREE CABLES Cables Limited MADE IN IRELAND SINCE 1934 QUALITY APPROVED CABLES IDH CABLES LIMITED FUMEGUARD TM LOW SMOKE HALOGEN FREE CABLES The longest-running original range of low voltage, low smoke, halogen free

More information

CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag

CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag STANDARD COLOR CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag TECHNICAL DATA SHEET Revision Number. 1 Last Edited 9. januar 2019 OTHER COLORS MATERIAL Flat band cross linked polyolefin. OPERATING

More information

ZH Low Smoke 0-Halogen Flameretardant Identification Sleeves

ZH Low Smoke 0-Halogen Flameretardant Identification Sleeves STANDARD TUBE COLOR ZH Low Smoke 0-Halogen Flameretardant Identification Sleeves TECHNICAL DATA SHEET Revision Number. 1 Last Edited 24. juli 2018 The ZH-2X Heat Shrinkable Wire Markers are made of halogen

More information

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW)

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW) SECTION 26 05 21 PART 1 - GENERAL 1.1 DESCRIPTION This section specifies the furnishing, installation, and connection of the low voltage power and lighting wiring. 1.2 RELATED WORK A. Excavation and backfill

More information

GCRG. Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection v7.0. Ordering Information.

GCRG. Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection v7.0. Ordering Information. GCRG Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection 05-05-7 v7.0 Ordering Information Belden Part Numbers Fibre Description / count 4 8 8 4 30 36 6.5/5-OM GCRG04

More information

Installation and Operation Manual

Installation and Operation Manual Electronic Thermostats with Ground Fault Equipment Protection Model SST 2 40 Freeze Protection Thermostat P/N 22744 MANUAL We Manage Heat Model SST 2 175 Fixed Set Point Thermostat P/N 23708 Installation

More information

Multipurpose Cables (indoor/outdoor), Multipurpose central tube cable (maxibundle) with glass yarn armouring A-DQ(BN)H 4-24

Multipurpose Cables (indoor/outdoor), Multipurpose central tube cable (maxibundle) with glass yarn armouring A-DQ(BN)H 4-24 Features and Benefits Laminated swelling glass yarns Improved rodent resistance and longitudinal water protection UV and microbe resistant Can be directly buried or installed in ducts Metal-free cable

More information

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable. Product Specification 108-93018 25/Aug/2011 Rev H Copper LAN cable 1. SCOPE 1.1. Content This specification describes the general requirements for AMP NETCONNECT* copper LAN cable. 2. APPLICABLE DOCUMENTS

More information

Application Specification

Application Specification Application Specification SOLARLOK connecting system for solar panels 1 of 31 Notification:... 3 1. Supplementary Documentation... 3 1.1 Customer Drawings... 3 1.2 Product Specifications... 4 1.3 Model

More information

Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive

Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive Illustrations Principle diagram Page 1/7 Product specification installation cable U-DQ(ZN)BH universal fiber optic cable for indoors/outdoors with central or stranded loose tube bend insensitive fiber

More information

SOLARLOK Interconnection System. RoHS. Ready

SOLARLOK Interconnection System. RoHS. Ready SOLARLOK Interconnection System RoHS Ready Table of Contents The SOLARLOK Concept.................................................... 1 Large Junction Box Serial Interconnection.....................................

More information

GUSA. Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection. Ordering Information.

GUSA. Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection. Ordering Information. GUSA Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count 2 4 6 8 12 62.5/125-OM1

More information

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE Draka, the world s mo When it comes to specifying fire performance cables, zero halogen building wires and power cables, you have to choose products

More information

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE Draka, the world s most trusted cable brand When it comes to specifying fire performance cables, zero halogen building wires and power cables, you have

More information

SPECIAL ELECTRICAL AND OPTICAL CABLES

SPECIAL ELECTRICAL AND OPTICAL CABLES SPECIAL ELECTRICAL AND OPTICAL CABLES INTRODUCTION The new high-speed trains and the sensible increase of the traffic, with congested lines, is the result of the latest development of the rail sector.

More information

Catalogue. Instrumentation & Control Cables

Catalogue. Instrumentation & Control Cables Catalogue Instrumentation & Control Cables Conductores Tecnológicos S.A. www.contecsa.es Index of Cables Page Introduction 3 Instrumentation VOV 4 VHOV 5 VOVMV 6 VHOVMV 7 Control RV 8 RZ1C3Z1 9 Conductores

More information

Product Guide. Fire Alarm Cables. Initiating Device, SLC Lines, and NAC Cables.

Product Guide. Fire Alarm Cables. Initiating Device, SLC Lines, and NAC Cables. Fire Alarm Cables Initiating Device, SLC Lines, and NAC Cables Product Guide STANDARDS Fire Alarm Systems A fire alarm system is number of devices working together to detect and warn people through visual

More information

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red OFC-UT-CST Fire resistant Armoured Indoor/Outdoor steel tape armoured (CST) double LSHF-FR sheathed optical cable with 2 24 fibres. VDE: A/I-DQ(ZN)H(SR)H 3rd party verification of the fire tests by BUREAU

More information

FlexLogic Slim. IP68 protected LED neon flex with a super-skinny illumination width of just 9mm. Product Brochure

FlexLogic Slim. IP68 protected LED neon flex with a super-skinny illumination width of just 9mm. Product Brochure FlexLogic Slim IP68 protected LED neon flex with a super-skinny illumination width of just 9mm Product Brochure Invisible LEDs deliver superb clarity and brightness Create continuous lines of flexible

More information

Comtran Cable. Hub-LINK Cables for Transit Applications

Comtran Cable. Hub-LINK Cables for Transit Applications Comtran Cable Hub-LINK Cables for Transit Applications Overview Hub-LINK rail transit cables are designed to resist the rugged conditions of the underground and at-grade environments, including: Temperature

More information

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Union County Vocational - Technical Schools Scotch Plains, New Jersey SECTION 220533 - HEAT TRACING FOR PLUMBING PIPING PART 1 - GENERAL 1.1 SUMMARY A. This Section includes plumbing piping heat tracing for freeze prevention, domestic hot-water-temperature maintenance, and

More information