Energy Management. Eos-Array. Launch Package 09. Michele Brena March, 2009

Size: px
Start display at page:

Download "Energy Management. Eos-Array. Launch Package 09. Michele Brena March, 2009"

Transcription

1 Energy Management Eos-Array Launch Package Michele Brena March, 2009

2 Contents INTRODUCTION Why this launch? Markets of interest Expectations THE PRODUCT Relevant technical data Product vs. Price Positioning Features and Benefits THE MARKET Competitors Relevant applications Market tools related and available CONCLUSIONS

3 Introduction Why this launch? To provide a complete control solution to the solar photovoltaic (PV) plants which is easy to install and to configure. To provide a flexible control solution which is suitable to be used in all PV plants from the very small 10kW up to megawatts installations. To strengthen our position in the Renewable Energy market providing now a complete solution which includes not only the energy metering and Inverters but also the control part. To support and exploit the huge business opportunities given by the European and Californian action plan to reduce both energy consumption and CO 2 so to meet the Kyoto protocol.

4 Introduction Markets of interest Renewable energy Solar market segment Expectations To strengthen our market position by providing a complete control solution for photovoltaic plants to be supplied to installers and engineering companies depending on the size of the plant; To confirm Carlo Gavazzi in its leading position as a provider of innovative solutions for energy management now also in the Solar renewable energy.

5 The Product VMU: Relevant Technical Data All modules Dimensions: 1-DIN module for DIN-rail mounting RS485 communication port (Modbus) on VMU-M only Front diagnostics LED s Universal 12 to 28 VDC power supply Protection degree (front): IP40 Operating temperature: -25 C to 55 C Storage temperature: -30 C to 70 C culus approved (December 2008)

6 The Product VMU: Relevant Technical Data VMU-M unit Local display: 6-DGT readout Local bus: up to 15 mixed VMU-S, VMU-P and VMU-O units Two temperature inputs: Pt100 or Pt1000, 3-wire (-50.0 to C) or two digital inputs: protection trip status and one either trip protection or energy counting Clock: European or American format selection with Daylight-saving enabling (internal battery) Real and virtual alarm management Data stamping format: date, time and V, A, W, Wh, PV cell temperature, environment temperature, irradiation, wind speed, string efficiency and DC/AC efficiency Data stamping interval: selectable minutes Events stamping: string alarm and other variable alarms DC/AC efficiency measurement

7 The Product VMU: Relevant Technical Data VMU-S unit Local bus: up to 15 VMU-S units in the same bus Direct measuring input: 16A/800VDC Accuracy: ±0.5 RDG (V-A), class 1 (kwh DC energy metering) Data format: 4-DGT and 6-DGT Measurements: V, A, W, Wh Diagnostics functions: antitheft control, fuse blow detection, wrong PV panel connection String control String efficiency measurement Power supply: self-power supply from VMU-M unit Screw terminal: up to 10mm 2

8 The Product VMU: Relevant Technical Data VMU-O unit Local bus: up to 7 VMU-O units (up to max. 15 mixed units) Two digital inputs for Trip of protection detection, remote input disable or others Two digital outputs for Alarm notification as a String alarm or as a digital input status changing (OR function); activation of a lighting system (by means of the internal clock or as a remote control); activation of a module washing system (by means of the internal clock, as a remote control or as a changing of efficiency of the PV panels). Output type: relay, SPST type (AC 250VAC, DC 24VDC, AC 250VAC, DC 24VDC) Power supply: self-power supply from VMU-M unit

9 The Product VMU: Relevant Technical Data VMU-P unit Local bus: one VMU-P unit per bus PV cell temperature measurement (Pt100-Pt1000, 3-wire) Environment temperature measurement (Pt100-Pt1000, 3-wire) One irradiation input (120mV) One wind speed input (0 to 1000Hz max.) Accuracy ±0.5 RDG Data format: 4-DGT Power supply: self-power supply from VMU-M unit

10 The Product Features and Benefits Control system based on modular concept easy to adapt to any solar application. INVENTORY REDUCTION Compact size: minimum 2-DIN module for minimum string control (up to 16 DIN modules in case of maximum configuration 280mm). Integrated string fuse protection. SPACE OPTIMISATION No need of local key-pad programming since all parameters can be set in an easier and quicker manner using Eos-ArraySoft software. Simplified installation since there is no need of auxiliary bus wiring. SIMPLIFIED SET-UP

11 The Product Features and Benefits RS485 for easy and quick data transmission to remote acquisition system. Local RGB LED on board of the VMU units for easy colour code diagnostics. Antitheft control, fuse blow detection, wrong PV panel connection for plant control and maintenance. Protection trip and breaker status detection by means of two digital inputs. Alarm notification and automatic PV panel cleaning by means of two relay outputs. String control for immediate string failure detection and localisation. String efficiency for energy production and pay-back control. DC/AC efficiency calculation for inverter working Control. Data and event logging for plant history built-up. COMMUNICATION CAPABILITI ES DIAGNOSTIC WARNING

12 Features and Benefits The auxiliary BUS concept VMU-M VMU-P VMU-S VMU-O The String controller Integrated fuse protection for cost and installation time saving Fuse dimension: 10.3x38mm (IEC ) Fuse current: Isc*1.25*2 using AC type Eos-Array can be formed by VMU-M, M, VMU-P, VMU-S and VMU-O units The auxiliary bus manages up to 16 VMU units VMU-M M has the task to manage the whole bus VMU-S can be up to max. 15 units VMU-O can be up to max. 7 units VMU-P can be up to 1

13 The Market The Control solution today Atersa Fronius Elettronica Santerno SMA Power-One

14 The Market The main parts composing a string box today Overvoltage protections Electronics for string control DC breaker String fuses String inputs and outputs screw terminals IP65 plastic box, usually with transparent cover

15 The Market The Eos-Array solution integrated into a standard plastic box Overvoltage protections DC breaker Eos-Array. String and sensor inputs. No further screw terminal needed More features and about 40% of space saving compared to an ordinary solution

16 The Market The control solution today The control solution today is based on two kind of products: Complex string controllers; Data-loggers. As far as complex String controller is concerned, there are at the moment a few suppliers which are: Elettronica Santerno (Italy) manufacturer of Inverters: String Box and Smart String Box. Power-one (USA) manufacturer of Inverters. SMA (Germany) manufacturer of Inverters: SSM Sunny String Monitor. Fronius (Austria) manufacturer of Inverters: Fronius String Control. Atersa (Spain): CSP-12.

17 The Market The control solution today (cont.) As far as data-logger is concerned the most important competitors are: Adyna Technology (Germany) : model IC.1, an Internet-Controller with several digital inputs and outputs. Tritec (Switzerland): model Tri-Logg a data-logger with digital, irradiation and temperature inputs. Meteotest (Switzerland): model SPYCE, Satellite photovoltaic yield control and evaluation unit (based on the European weather satellite Meteosat 8). AS Solar (Germany): model PV interface and V-Central, yield data and malfunction notification. Common-Link (Germany): InterLink-Solar, digital and analogue inputs data-logger. Conergy (Germany): SunReader, digital and analogue inputs data-logger. Solare Datensysteme (Germany): SolarLog, yield measurements and malfunction notifications coming from inverter only. Meteocontrol (Germany): WebLog, complete performance monitoring system, supplied to many inverter manufacturer. Draker Laboratories (USA): Sentalis 200, DC string monitoring providing system performance.

18 The Market The control solution today (cont.) Fat Spaniel Technologies (USA): leading US supplier of performance monitoring systems and incentive program reporting to system integrators, providers of power purchase agreements and inverter manufacturers such as: Xantarex, SatCon Power Systems, Solectria Renewables and others. Dhiel AKO Stiftung (Germany): Platinum, yield measurements and malfunction notifications coming from inverter only (inverter option). Kaco Gerätetechnik (Germany): Powador-pro-LOG, data-logger with temperature and irradiation inputs, gathering yield data from inverters only (inverter option). Sunways (Germany): data-logger with temperature and irradiation inputs, gathering yield data from inverters only (inverter option). SMA Technologie (Germany): Sunny Boy Control Plus, data-logger with temperature and irradiation inputs, gathering yield data from inverters only (inverter option). Sputnik Engineering (Switzerland): MaxWeb, data-logger with temperature and irradiation inputs, gathering yield data from inverters only (inverter option). Fronius International (Austria): DataCom + Fronius Sensor Box, data-logger with temperature and irradiation inputs, gathering yield data from inverters only (inverter option).

19 The Market Competitors Product name Strength Weakness Prod. picture I checker Only one DIN module width Integrated protection fuse Voltage measurement up to 800VDC Accurate kwh energy measurement Integrated antitheft control Inverted string polarity detection Part of a modular photovoltaic control system providing local data and event logging, yield data information and others. Touch less current measurement DC current measurement up to 70A

20 The Market Relevant applications Solar plant control The installer has to provide to his customer a 50kWp photovoltaic plant to be mounted on the roof of a production facility to produce energy mainly for their own use. The available control solutions are based on the information coming out from the inverters which are still the weakest component of a PV solar system. The company doesn t like it and as an alternative looks for a system capable to measure the string currents in order to keep them under control. A data logging system is also needed to understand how the solar installation works and behaves along the time. Our solution is an innovative local system based on the Eos-Array system composed by one VMU-M unit for data logging and local bus management, ten VMU-S units for string control (50kW total for 228x220W PV panels, 12.5A/400V single string), one VMU-O for I/O managements and one VMU-P for environment measurements. Last but not least one freeware Eos-ArraySoft software to be installed in a local PC to gather string efficiency and single string variables such as current, active power, voltage, energy, sun irradiation and PV cell temperature to built up the plant history. Thanks to the modular concept the installer can size the installation according to his project philosophy and install it in a very easy and fast way. A further cost saving is provided by the integrated string fuse protections. The system functions and controls are split into modules so to improve the global reliability of the system. The integrated I/O VMU-O unit can acquire the status of the overvoltage protection and acquire the pulses coming out from the local utility watt-hour meter so to measure the generated energy. As far as outputs is concerned the first relay can provide a physical failure alarm so to promptly warn the maintenance people and the second alarm, by means of the integrated antitheft control system (no extra wiring is needed) can provide a proper warning in case of unauthorized PV panels removal. The local string efficiency and the inverters are controlled locally and continuously so to provide, in case of failure, an easy and fast problem localisation which is mandatory for a plant when either un-efficiency or a stop means money loss.

21 The Market Example of our Solar plant control solution Sensing Generation DC Carlo Gavazzi Inverter EM24-DIN kwh Eos-Array (VMU-M M VMU-S VMU-P VMU-O) Control solution DPC Protection AC GRID Eos-ArraySoft Database and graphs display

22 Example of our Solar plant control solution PV string 1 PV string 2 Pulse PV string 3 Inverter 1 kwh meter Inverter 2 Inverter 3 Eos-Array RS485 VCP-DIN Ethernet Eos-ArraySoft Manual or automatic data download for yield data analysis

23 The Market Market Tools DATASHEETS The Eos-Array datasheet is available in the Download area of the Carlo Gavazzi web site. It is available in English, Italian, French, German, and Spanish versions. Eos-Array DS English version (pdf file) Eos-Array DS Italian version (pdf file) Eos-Array DS French version (pdf file) Eos-Array DS German version (pdf file) Eos-Array DS Spanish version (pdf file) Link to the datasheet download area

24 The Market Market Tools INSTRUCTION MANUALS Every Eos-Array module is supplied with an instruction folder, available in multilanguage format (English-Italian- Spanish-French-German version). Eos-Array MP IM ML version (pdf file) Eos-Array SO IM ML version (pdf file) Link to the datasheet download area

25 The Market Market Tools INSTRUCTION MANUALS Eos-ArraySoft the parameter programming software and its instruction folder, available in multilanguage format (English-Italian- Spanish-French-German version) is freely downloadable from our web-site. Eos-ArraySoft IM ML version (pdf file) Link to the datasheet download area

26 Conclusions Eos-Array Eos-Array is a complete and modular system specifically developed for Solar plant control based on single 1-DIN modules with different functionalities. Eos-Array with its string control module and integrated protection fuse is also a space saving solution. Eos-Array is a cost effective solution which focuses on reliability, expandability and flexibility: the PV installation control can be easily tailored according to the plant size and the application needs (from 10kWp onwards). Eos-Array splits the measurement and control functions into different modules so to improve the global reliability of the Solar control system. Eos-Array with its efficiency and local alarm management provides a fast problem localization while Eos-ArraySoft, a freeware software, either automatically or manually can download the Eos-Array system memory for further yield data and alarm analysis. Eos-Array is easy to install and because its modular concept is suitable to be sold also using the distributor sales channels.

27 Conclusions Eos-Array Eos-Array has not real competitors because the market today offers totally different and incomparable solutions Eos-Array unique features are recognizable by a specific logo. More will come in the feature

SUPREMATouch. Modular Fire & Gas Detection System

SUPREMATouch. Modular Fire & Gas Detection System SUPREMATouch Modular Fire & Gas Detection System Tel: +44 (0)8 9388 Email: info@ Fire & Gas Detection Solutions MSA permanent gas detection systems are used throughout the world to protect plant and personnel

More information

Dew point set DS 400

Dew point set DS 400 set DS 400 Dew point set DS 400 for stationary dew point monitoring of refrigeration or adsorption dryers. The touch screen graphic display enables an intuitive operation and shows the progress of the

More information

AS950 PORTABLE SAMPLERS

AS950 PORTABLE SAMPLERS AS950 PORTABLE SAMPLERS Applications Wastewater Collections Industrial Pretreatment Environmental Monitoring Stormwater Sampling has never been this easy. The AS950 Portable Sampler makes programming,

More information

SUPREMATouch. Modular Fire & Gas Detection System

SUPREMATouch. Modular Fire & Gas Detection System SUPREMATouch Modular Fire & Gas Detection System Fire & Gas Detection Solutions MSA permanent gas detection systems are used throughout the world to protect plant and personnel from hazardous gases in

More information

RAYCHEM NGC-30 COMPONENTS

RAYCHEM NGC-30 COMPONENTS PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM PRODUCT OVERVIEW CABLE DUCT Card Rack Modules TERMINAL STRIP PLINTH MAIN SWITCH 800 mm USER INTERFACE

More information

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM Card Rack Modules CABLE DUCT MAIN SWITCH 800 mm USER INTERFACE TERMINAL PRODUCT OVERVIEW The nvent

More information

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510 Dew point monitoring DS 400 for stationary dew point monitoring of refrigeration or desiccant driers. The touch screen graphic display enables an intuitive operation and shows the progress of the measured

More information

AS950 REFRIGERATED SAMPLERS

AS950 REFRIGERATED SAMPLERS AS950 REFRIGERATED SAMPLERS Applications Wastewater Collections Industrial Pretreatment Environmental Monitoring Stormwater Sampling has never been this easy. The AS950 Refrigerated Sampler makes programming,

More information

Controllers, Indicators & Set Point Programmers

Controllers, Indicators & Set Point Programmers Controllers, Indicators & Set Point Programmers PROCESS CONTROL MADE EASY Honeywell Solutions for Indicators and Controls Honeywell Controllers DC 1010 DC 1020 UDC 100 UDC 700 Honeywell supports your process

More information

IMM TECHNOLOGY YOUR SOLAR PLANT AT YOUR FINGERTIPS WHAT IS IMM? WHY IMM? PL EN V1.1

IMM TECHNOLOGY YOUR SOLAR PLANT AT YOUR FINGERTIPS WHAT IS IMM? WHY IMM? PL EN V1.1 IMM TECHNOLOGY YOUR SOLAR PLANT AT YOUR FINGERTIPS PL01808 EN V1.1 WHAT IS IMM? IMM (Individual Module Monitoring) is an advanced solar plant monitoring at module level managed by artificial intelligence

More information

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

AS950 ALL-WEATHER REFRIGERATED SAMPLERS AS950 ALL-WEATHER REFRIGERATED SAMPLERS Applications Wastewater Collections Industrial Pretreatment Environmental Monitoring Stormwater Sampling has never been this easy. The AS950 All-Weather Refrigerated

More information

Billion Watts Technologies. Professional Solar Monitoring & Management System

Billion Watts Technologies. Professional Solar Monitoring & Management System Billion Watts Technologies Professional Solar Monitoring & Management System Pixel View Professional Solar PV Monitoring and Management System Global warming, technology advancement, cost reduction, and

More information

Specification for On-Line UPS Battery Monitoring and Data Management System

Specification for On-Line UPS Battery Monitoring and Data Management System 1 Scope This specification defines the minimum requirements for a predictive on-line Battery Monitoring BMDMS with test, analysis, and remote monitoring control capabilities. Unless noted otherwise, the

More information

SOLAR SOLUTIONS FROM FOR PROPERTY DEVELOPERS

SOLAR SOLUTIONS FROM FOR PROPERTY DEVELOPERS SOLAR SOLUTIONS FROM FOR PROPERTY DEVELOPERS By Vickrogers Macharia SOLAR ENERGY PRINCIPLES Energy emitted by the sun Measure in watts/m 2, at standard testing conditions max solar irradiance = 1000w/m

More information

EasyLog Data Logger Series

EasyLog Data Logger Series EasyLog Data Logger Series Overview EasyLog model EL-USB series products are a line of low cost, compact, battery-operated data loggers with built-in memory and USB interface. Each product in the line

More information

Batt-Safe Battery String Monitoring System

Batt-Safe Battery String Monitoring System Batt-Safe Battery String Monitoring System Technical White Paper October 2010 Introduction Battery monitoring systems are categorized as either cell monitors or string monitors. Battery cell monitors provide

More information

MultiMeter 44. Transmitter-regulator with 1, 2 or 3 channels. Quality at a reasonable price

MultiMeter 44. Transmitter-regulator with 1, 2 or 3 channels. Quality at a reasonable price MultiMeter 44 Transmitter-regulator with 1, 2 or 3 channels MultiMeter 44 is a modular meter that can be configured with one, two or three channels. It can be delivered with only one measuring channel,

More information

Measuring Recording Online Monitoring Regulation Alarming

Measuring Recording Online Monitoring Regulation Alarming Measuring Recording Online Monitoring Regulation Alarming Temperature Humidity CO 2 Dew point Atmospheric pressure Analog signals Two-state inputs Pulses Battery operated recorders and printers Economical

More information

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS NOVA PD56 Series Thermocouple, RTD, & Process Inputs Universal Power Supply 1-24 VAC Up to 3 Alarm Relays Retransmitting 4-2 ma Output Input Max/Min

More information

HTC-915-CONT. Heat-Trace Control system

HTC-915-CONT. Heat-Trace Control system Heat-Trace Control system Product overview The Raychem HTC-915 system is a compact, full-featured microprocessor-based single-point heat-trace controller. The HTC-915-CONT provides control and monitoring

More information

Added password for IP setup page : Password must be in IP format!

Added password for IP setup page : Password must be in IP format! NETWORK POWER MONITOR Release : 21 August 2014 Hardware Version : Version 7 Firmware version 1.00 PC Application Software : Version (latest)...2 Added password for IP setup page : Password must be in IP

More information

EasyLog Data Logger Series

EasyLog Data Logger Series EasyLog Data Logger Series Overview EasyLog model EL-USB series products are a line of low cost, compact, battery-operated data loggers with built-in memory and USB interface. Each product in the line

More information

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Process & TeMPerATUre UniversAl input DigiTAl MeTers Process & TeMPerATUre UniversAl input DigiTAl MeTers nova PD56 series Thermocouple, rtd, & Process inputs Universal Power supply 1-24 va c Up to 3 Alarm relays retransmitting 4-2 ma output input Max/Min

More information

APPLICATION DATA SHEET

APPLICATION DATA SHEET APPLICATION DATA SHEET Control Systems Transmitters Sensors Accessories Wall, 19 Rack or Panel Mounting Units 110/230V 50/60Hz AC operation 250 Addressable devices as: Relays, 4-20 Inputs or Gas Detectors

More information

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0) Serie 5000 Tel. +1 (0)5 222 Fax +1 (0)5 222 12 PRODUCT INTRODUCTI PRODUCT INTRODUCTI 5 Series programmable temperature controller is FineTek's mid-range series of controllers. It uses a 12bit analog /

More information

Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping. Touch Panel PPI

Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping. Touch Panel PPI HumiTherm Ultra Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping Mapping Unit Micro PLC Control Unit Touch Panel Touch Operation Panel PPI HumiTherm Ultra GSM Module

More information

Engineering Guideline. pac- Carriers Type Universal

Engineering Guideline. pac- Carriers Type Universal Engineering Guideline pac- Carriers Type 9195 Universal Integration of conventional process automation interfaces pac- Carrier The pac- Carrier reflects the intention of R. STAHL to provide state-of-the-art

More information

PowerWizard. Level 1.0 & Level 2.0 Control Systems Training

PowerWizard. Level 1.0 & Level 2.0 Control Systems Training PowerWizard Level 1.0 & Level 2.0 Control Systems Training New Systems Current Systems Systems Comparison Level 1 Level 2 Level 3 Level 4 PowerWizard Level 3.0 PowerWizard Level 4.0 Overview Common parts

More information

ThermoControl 0 C - 10 C - 20 C - 30 C

ThermoControl 0 C - 10 C - 20 C - 30 C ThermoControl Product and Quality Reliability Alarm Functions & Documentation Global Monitoring 0 C - 10 C - 20 C - 30 C Global monitoring: global temperature measurement and real-time monitoring using

More information

Universal fault annunciator for panel mounting

Universal fault annunciator for panel mounting Universal fault annunciator for panel mounting Communication over Ethernet USM - Universal-fault annunciator for panel mounting Low depth housing for panel mounting Versions with 8, 16, 32 or 48 inputs

More information

CTT8 TEMPERATURE MONITOR DEVICE

CTT8 TEMPERATURE MONITOR DEVICE INSTRUCTION MANUAL IM302-U v2.3 CTT8 TEMPERATURE MONITOR DEVICE GENERALITY The device of control temperatures CTT8 is used in the control of electric machine, transformer, motor, etc. where it s possible

More information

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules Engineering Guideline pac-carriers Type 9195 SIEMENS ET-200M Fail-safe signal modules pac-carrier Type 9195 2 Engineering Guideline/SIEMENS 19.05.2015 pac-carrier Type 9195 Integration of conventional

More information

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals Technical Information RTA421 Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals Application Plant and machine construction Panel builders Process monitoring Process

More information

DIVA8MG2. Compact PAVA System Master Unit. DIVA8 System

DIVA8MG2. Compact PAVA System Master Unit. DIVA8 System DIVA8MG2 Public Address - Voice Alarm Audio Distribution over IP Commercial Audio Intelligent Acoustic Solutions Intercommunication Loudspeakers Compact PAVA System Master Unit DIVA8 System DIVA8 system

More information

ACTIVE INFRARED BARRIER

ACTIVE INFRARED BARRIER Although PROTECH provides high security indoor intrusion sensors for the military and government markets, our specialty is outdoor protection. Since we first introduced our PIRAMID outdoor dual technology

More information

Panel Mounted Fault Annunciator Series

Panel Mounted Fault Annunciator Series Panel Mounted Fault Annunciator Series BSM / USM Panel-mounted fault annunciator Annunciators for panel mounting with 8, 16, 24, 32, 40 and 48 signal inputs Status retention of inputs and sequence in case

More information

Alarm module for leak detection with webserver

Alarm module for leak detection with webserver This instruction document consists of 2 parts : one part about the assembly of the components and one part about configuration and starting-up of the system. The assembly is done by the qualified installer

More information

THX-DL Data Logger USER & INSTALLATION MANUAL V

THX-DL Data Logger USER & INSTALLATION MANUAL V THX-DL Data Logger USER & INSTALLATION MANUAL V1.2012 www.thermomax-refrigeration.com Contents PRESENTATION Summary of Features 2 INSTALLATION Safety Precautions 4 THX Unit 4 Sensors 4 Alarm Relay 4 Power

More information

Gas Controller Module GC-06

Gas Controller Module GC-06 Page 1 Oct. 2015/2 Measuring, warning and controlling module for toxic, combustible and refrigerant gases and vapours. The gas controller series GC-06 is designed in accordance with the standard EN 50545-1.

More information

MO n : 12JMC rév A

MO n : 12JMC rév A CTT8 MO n : rév A Page 2 / 18 MODIFICATIONS Rev. Description Date Checked by Approuved by Z Creation 2012/02/12 JMC LA A First issue 2012/02/14 JMC LA INDEX Page 3 / 18 GENERALITY 4 INTRODUCTION 4 ACCESSORIES

More information

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014 Solar Charge controller with Ethernet Release : 19 June 2014 Hardware Version : Version 1 Firmware version 1 PC Application Software : Version 1.0.0.0 Hardware Description : The Solar Smart regulator was

More information

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems X X testregistrierung Type Web server, also for mobile devices Zone modules Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems X-AIRCONTROL zone

More information

Panel Mounted Fault Annunciator Series

Panel Mounted Fault Annunciator Series Panel Mounted Fault Annunciator Series BSM / USM Panel-mounted fault annunciator Annunciators for panel mounting with,,,, 0 and signal inputs Storage of the last state of inputs and sequence in the case

More information

PowerRouter application guideline

PowerRouter application guideline PowerRouter application guideline Software installation tool - version 3.4 Before operating the PowerRouter, you may initialize the PowerRouter by using the PowerRouter software installation tool. The

More information

CATALOGUE Controls/Networks STRACK LIFT AUTOMATION. MULTiBUS -Coupler

CATALOGUE Controls/Networks STRACK LIFT AUTOMATION. MULTiBUS -Coupler CATALOGUE Controls/Networks 2018.1 -Coupler 1.3 Controls/Networks 2018.1 -Coupler -Coupler -Coupler Controls/Networks 2018.1 1.3 Extend (third-party) lift controls with LIFTnet, a dynamic fire control

More information

LORAIN CIP 4890/48120 DC Power System

LORAIN CIP 4890/48120 DC Power System DC Power for Business-Critical Continuity Key Features Compact flexibility provides rectifiers, distribution, and controller in one shelf Constant power delivers more current at lower voltages to meet

More information

NEWS THEBEN THEBEN 2

NEWS THEBEN THEBEN 2 english NEWS 2010 NEWS THEBEN THEBEN 2 THEBEN NEWS New Theben products in 2010 THEBEN Dear clients and partners, Find out about our new products and energy-saving solutions for building automation: The

More information

Designation and Construction of Solar Panel-based Washing Machine. Seyed Amin Hashemi 1, Saeed Zamani 2

Designation and Construction of Solar Panel-based Washing Machine. Seyed Amin Hashemi 1, Saeed Zamani 2 Designation and Construction of Solar Panel-based Washing Machine Seyed Amin Hashemi 1, Saeed Zamani 2 1. Department of Electronic, Kerman branch, Islamic Azad University, Kerman, Iran 2. MA, Department

More information

HOBO U30 Remote Monitoring Systems

HOBO U30 Remote Monitoring Systems onset HOBO U30 Remote Monitoring Systems Web-based environmental monitoring All electronics housed within a research-grade, tamperproof enclosure Setup is quick and easy with plug-and-play sensors GSM

More information

L CONNECTION NETWORK Commercial Controls

L CONNECTION NETWORK Commercial Controls L CONNECTION NETWORK Commercial Controls SIMPLIFIED, CENTRAL CONTROL Simplified Control for Your Facility The L Connection Network not only enhances comfort and energy-efficiency throughout your facilities,

More information

EL-OEM-3 OEM Packaged Voltage Data Logger

EL-OEM-3 OEM Packaged Voltage Data Logger FEATURES PCB Mounted (2.54mm pitch, header sockets) 0 to 2.4V d.c. Measurement Range Logging Rates between 1s and 12hr Stores 64,000 readings USB interface for set-up and data download (USB connector not

More information

The product segments Heating, ventilation, air conditioning. Control Products & Systems OEM.

The product segments Heating, ventilation, air conditioning. Control Products & Systems OEM. The product segments Heating, ventilation, air conditioning Control Products & Systems OEM www.siemens.com/buildingtechnologies-oem The right product for every application Siemens specializes in the development,

More information

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460) Operating Manual TS400 Test Station for Microtector II Series (G450/G460) GfG GESELLSCHAFT FÜR GERÄTEBAU MBH KLÖNNESTRASSE 99 44143 DORTMUND, Germany TEL. +49 / (0)2 31 / 5 64 00 0 FAX +49 / (0)2 31 /

More information

RACK MONITORING SYSTEM RAMOS Ultra

RACK MONITORING SYSTEM RAMOS Ultra version: 7-05-03 CONTEG DATASHEET COMPLEMENTARY SYSTEMS RACK MONITORING SYSTEM CONTEG, spol. s r.o. Czech Republic Headquarters: Na Vítězné pláni 79/4 40 00 Prague 4 Tel.: +40 6 9 8 Fax: +40 6 9 9 Production

More information

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture meas. according to ISO 8573 Residual oil content - particles - moisture DS 500 - the intelligent chart recorder of the next generation. The centerpiece of compressed air quality measurement is the chart

More information

Smart Combiners CG-VMU SolarVu. Installation Guide

Smart Combiners CG-VMU SolarVu. Installation Guide Smart Combiners CG-VMU SolarVu Installation Guide Introduction This installation guide is for communications wiring to combiner boxes that use the Carlo Gavazzi Eos Array VMU-M comms module and smart sensors

More information

Nardalert S3 TM Non-Ionizing Radiation Monitor

Nardalert S3 TM Non-Ionizing Radiation Monitor Patent Pending Nardalert S3 TM Non-Ionizing Radiation Monitor Field Replaceable Sensor Modules Color LCD Display Multi-Color Alarm LED s USB Interface for Data and Charging Comprehensive Software Included

More information

www

www HettCube INCubatORS AND COOLED INCubatORS sustainable. ERGONOMIC. HIGH QUALITY. www.hettichlab.com THE HettCube RANGE GET THE MOST OUT OF YOUR INCubatORS. ENVIRONMENTALLY FRIENDLY, ECONOMICAL AND WELL

More information

Touchpoint Plus. A whole new control experience

Touchpoint Plus. A whole new control experience Touchpoint Plus A whole new control experience Touchpoint Plus Delivering reliable control Honeywell reliability from the most trusted experts in gas detection Built-in battery backup for constant uptime

More information

APS-Series 1500VDC OUTDOOR SOLAR INVERTER

APS-Series 1500VDC OUTDOOR SOLAR INVERTER OUTDOOR SOLAR INVERTER The APS-Series are outdoor PV central inverters for large PV fields with voltages up to 1500 VDC. The APS-Series is a plug and play solution for your installations. It includes all

More information

Process Alarm Solutions

Process Alarm Solutions Process Alarm Solutions Reliable Supervision and Control» Control. Monitor. Protect. SELCO Flexible alarm panels for supervision and control SELCO provides efficient and reliable solutions for alarm monitoring

More information

Product Information. PipeMonitor District Heating Monitoring with Leak Localisation

Product Information. PipeMonitor District Heating Monitoring with Leak Localisation The thresholds for insulation and loop resistance are programmable via built-in buttons which are shown in the display of the main module. In addition to the settings the display can also indicate the

More information

SmartAlarm Annunciator

SmartAlarm Annunciator Annunciator Specification/Features The Annunciator offers a modern compact DIN package that includes state of the art critical alarm capture in an industry standard footprint 1. High Intensity LED s 2.

More information

EC2-5x2 Series Condensing Unit Controllers

EC2-5x2 Series Condensing Unit Controllers Technical Data The EC2-Series form a new generation of electronic controllers for refrigeration and air conditioning. The controllers combine in the small industry standard housing maximum functionality

More information

Parameterisable compact fault annunciator with permanent display

Parameterisable compact fault annunciator with permanent display Parameterisable compact fault annunciator with permanent display FSM 10 Drop-flap fault annunciator 31.08.2010 Permanent display even on power failure Compact module for 10 alarms Supply and alarm signal

More information

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM APPLICATION OVERVIEW Control and monitoring systems play an essential role in heat tracing applications which range from freeze protecting water lines to

More information

FireNET Plus Wiring Instructions

FireNET Plus Wiring Instructions FireNET Plus Wiring Instructions This manual provides wiring instructions for the 1 loop and 2 loop version of the FireNET Plus panels, which supports our finest Hochiki s DCP protocol. Note: Refer to

More information

Advanced FireAlarm Panel 1-4Loop

Advanced FireAlarm Panel 1-4Loop Advanced FireAlarm Panel 1-4Loop Advanced Technologies Advanced Electronics Ltd IP Gateway Monitoring and interrogation via the internet Password protected multiple user permissions Event notification

More information

LORAIN CSP DC Power System

LORAIN CSP DC Power System DC Power for Business-Critical Continuity Key Features Compact flexibility provides more space for revenue generating equipment Constant power delivers more current at lower voltages to meet load or recharge

More information

The EN54 Part 2, 4 and 13 Fire System

The EN54 Part 2, 4 and 13 Fire System Scope of work: To design, supply, install and commission an Analogue Addressable Fire Alarm Control System in accordance with the details specified herein and in accordance with supplied drawings The EN54

More information

LC150 VIEW-AT-A-GLANCE PUMP CONTROL-TELEMETRY UNIT

LC150 VIEW-AT-A-GLANCE PUMP CONTROL-TELEMETRY UNIT LC150 VIEW-AT-A-GLANCE PUMP CONTROL-TELEMETRY UNIT Simply Features In Brief Telemetry Ready Security 2 or 3 Pump Control UL Listed Alarm/Event Log Volumetric Flow Calculator VFD Control Optional Dialer

More information

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS Engineering Guideline pac-carriers Type 9195 for Yokogawa ProSafe-RS 2 Engineering Guideline / Yokogawa ProSafe-RS 06.06.2017 Integrated solutions for Yokogawa R. STAHL offers a wide range of customized

More information

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW 12/23/16 Rev 9 UltraLITE Model ELU General Specification 4.2 KW to 5 KW UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW 1.0 General General Specification This specification describes

More information

i-con Switchgear Condition Monitoring HV Switchgear Integrated Substation Condition Monitoring ISCM Answers for Infrastructure & Cities.

i-con Switchgear Condition Monitoring HV Switchgear Integrated Substation Condition Monitoring ISCM Answers for Infrastructure & Cities. i-con Switchgear Condition HV Switchgear Integrated Substation Condition ISCM Answers for Infrastructure & Cities. The challenge: Reliable energy supply is the key to success for every enterprise in a

More information

APS-Series 1000VDC OUTDOOR SOLAR INVERTER

APS-Series 1000VDC OUTDOOR SOLAR INVERTER OUTDOOR SOLAR INVERTER The APS-Series are outdoor PV central inverters for large PV fields with voltages up to 1000 VDC. The APS-Series is a plug and play solution for your installations. It includes all

More information

ModBus DE-1 INSTALLATION AND USER MANUAL

ModBus DE-1 INSTALLATION AND USER MANUAL ModBus DE-1 INSTALLATION AND USER MANUAL INTESIS Software, SL Distributed by DURAN ELECTRONICA S.L Tomás Bretón 50 28045 MADRID, España duran@duranelectronica.com www.duranelectronica.com 2 2010 DURAN

More information

CLIMAV 2.0 Thermoregulation Systems

CLIMAV 2.0 Thermoregulation Systems Thermoregulation Systems EN 2 TIEMME, INNOVATION FOR A STEADY GROWTH Tiemme Raccorderie is an international leader in the production and marketing of plumbing and heating components. Experience, innovative

More information

ATSTORM v2. The sensor with FCES technology is connected to the interface with a communication cable.

ATSTORM v2. The sensor with FCES technology is connected to the interface with a communication cable. ATSTORM v2 ATSTORM v2 is a storm detector that measures the environmental electric field. It is fully automatic, without mobile parts, robust and highly reliable The storm detector ATSTORM v2 basic configuration

More information

PHOTOVOLTAIC HEAT CONTROLER PVHC 2.01 USER MANUAL

PHOTOVOLTAIC HEAT CONTROLER PVHC 2.01 USER MANUAL USER MANUAL CONTENT CONTROL ELEMENTS AND CONNECTIONS... 3 HOW IT WORKS... 4 INSTALLATION PROCEDURE, SWITCHING ON THE DEVICE... 5 CONNECTION DIAGRAM... 6 USER MENU... 7 SPECIFICATIONS... 11 EU Declaration

More information

designed for rail 5000 Series

designed for rail 5000 Series designed for rail 5000 Series 5000 Series The only complete SIL system 20 years of experience in the field. More than 15.000 systems supplied worldwide. A team devoted to rolling stock projects with specialized

More information

2-zone application 2X T6R SMART THERMOSTAT & 2-CHANNEL RECEIVER BOX FEATURES APPLICATION MANUAL

2-zone application 2X T6R SMART THERMOSTAT & 2-CHANNEL RECEIVER BOX FEATURES APPLICATION MANUAL 2-zone application 2X T6R SMART THERMOSTAT & 2-CHANNEL RECEIVER BOX APPLICATION MANUAL FEATURES With the new 2-channel Receiver box (R6H911RF) and 2x a T6R wireless smart thermostats (T6H700RW) automatic

More information

USER MANUAL USB Multi-Function Datalogger Model RHT35

USER MANUAL USB Multi-Function Datalogger Model RHT35 USER MANUAL USB Multi-Function Datalogger Model RHT35 Additional User Manual Translations available at www.extech.com Introduction Thank you for selecting the Extech multi-function, easy-to-use, portable

More information

GasGard 100 Control System

GasGard 100 Control System GasGard 100 Control System Because every life has a purpose... MSA Providing Fixed Gas and Flame Detection Solutions. It is critical for plant managers and personnel to have a proactive and diagnostic

More information

CM901 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

CM901 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET CM90 PROGRAMMABLE THERMOSTAT PRODUCT SPECIFICATION SHEET FEATURES Attractive, slim, ultra-modern styling makes it ideal for location in any type of home. 24 hour heating program. A dynamic text display

More information

SAUTER ecos504/505. The modular room controller for demand-controlled, integral room automation.

SAUTER ecos504/505. The modular room controller for demand-controlled, integral room automation. SAUTER ecos504/505 The modular room controller for demand-controlled, integral room automation. SAUTER ecos504/505 room controller. The smart solution. Integrated room automation for more comfort and efficiency.

More information

R E C T I F I E R I N V E R T E R C O N V E R T E R SB7

R E C T I F I E R I N V E R T E R C O N V E R T E R SB7 SCR Battery Charger Product Specifications Description The is RIC Electronics premiere SCR battery charger/rectifier. The provides power to critical DC loads through a wide range of outputs and is engineered

More information

USB Multi Function Dataloggers. RHT30 Humidity/Temperature Datalogger. TH30 Dual Temperature Datalogger

USB Multi Function Dataloggers. RHT30 Humidity/Temperature Datalogger. TH30 Dual Temperature Datalogger USER MANUAL USB Multi Function Dataloggers RHT30 Humidity/Temperature Datalogger TH30 Dual Temperature Datalogger Additional User Manual Translations available at www.extech.com Introduction Thank you

More information

Medical Refrigerators

Medical Refrigerators Medical Refrigerators B Medical Systems Range Medical Refrigerators are devices intended for the safe storage of laboratory and pharmaceutical preparations at cold temperatures between +4 C and +15 C.

More information

PRODUCTS AND SOLUTIONS FOR PUMPING, IRRIGATION AND PIPING

PRODUCTS AND SOLUTIONS FOR PUMPING, IRRIGATION AND PIPING PRODUCTS AND SOLUTIONS FOR PUMPING, IRRIGATION AND PIPING TRA DITIONS AND INNOVATION Since 1922 The first LOVATO Electric headquartes founded in Bergamo in 1922: the starting point of the grand industrial

More information

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM APPLICATION OVERVIEW Control and monitoring systems play an essential role in heat tracing applications which range from freeze protecting water lines to

More information

SmartVFD HVAC and BYPASS

SmartVFD HVAC and BYPASS SmartVFD HVAC and BYPASS The Smart Choice For Energy Savings Energy Savings Are Smart For You. And Smart For The World. About three-quarters of the energy consumed by commercial buildings is in the form

More information

D3 Wireless temperature alarm & monitoring system family. tek-troniks

D3 Wireless temperature alarm & monitoring system family. tek-troniks D3 Wireless temperature alarm & monitoring system family tek-troniks D3 Wireless temperature alarm & monitoring system family No server or dedicated pc No ongoing cloud costs or licencing fees. Fully web

More information

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM Local configuration and monitoring with Raychem Touch 1500 touch screen display PRODUCT OVERVIEW The Raychem NGC-40 is a multipoint electronic

More information

THERMO BUTTON HYGRO BUTTON The smallest temperature and humidity loggers in the world!

THERMO BUTTON HYGRO BUTTON The smallest temperature and humidity loggers in the world! THERMO BUTTON HYGRO BUTTON The smallest temperature and humidity loggers in the world! FOR ALL YOUR TEMPERATURE AND HUMIDITY CONTROLS, PRODUCT TRACKING, TRANSPORT, STORAGE CONTROLS, HACCP! Small, rugged,

More information

LOAD LIMITER S CONTROL

LOAD LIMITER S CONTROL LOAD LIMITER P SPRING machine control } DAVIDE vs GOLIA 2-3 This family of products is the result of the work of a team that has been carrying out for more than 20 years. We have been designing manufacturing

More information

UMWELTSIMULATION TEMPERATUR VARIO. Walk-in chambers in modular design for multifunctional applications in different industrial fields

UMWELTSIMULATION TEMPERATUR VARIO. Walk-in chambers in modular design for multifunctional applications in different industrial fields UMWELTSIMULATION TEMPERATUR VARIO Walk-in chambers in modular design for multifunctional applications in different industrial fields UMWELTSIMULATION TEMPERATUR UMWELTSIMULATION TEMPERATUR With the Vario

More information

THE CHANGE IN GEAR ENGINEERING

THE CHANGE IN GEAR ENGINEERING THE CHANGE IN GEAR ENGINEERING THE GEARING OF THE FUTURE IS ELECTRIFIED, AUTOMATED AND NETWORKED. GEARCONTROL: i:gear 4.0 GEARCONTROL-SYSTEM GEARCONTROL-OIL EISENBEISS LEADING THE WAY IN SPECIAL GEAR ENGINEERING

More information

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR 2 MB 103 TRANSFORMER TEMPERATURE CONTROL UNIT WITH CONTROL SIGNAL Recent approval of new

More information

On the job around the clock 24/7: Fire detection systems

On the job around the clock 24/7: Fire detection systems On the job around the clock 24/7: Fire detection systems Version 02.2010 Version: 02.2010 Product catalogue Fire detection systems This product catalogue is intended for sales purposes only. For planning,

More information

SAFEMASTER PRO. The configurable safety system versatile and extendable. Our experience. Your safety.

SAFEMASTER PRO. The configurable safety system versatile and extendable. Our experience. Your safety. SAFEMASTER PRO The configurable safety system versatile and extendable Our experience. Your safety. The modular safety system: Safe flexibility SAFEMASTER PRO: also as a stand-alone solution You may know

More information