How To Complete E-Scores

Size: px
Start display at page:

Download "How To Complete E-Scores"

Transcription

1 How To Complete E-Scores Appendix f- Life Safety Code National Fire Safety Association A PROCEDURE FOR DETERMINING EVACUATION CAPABILITY This Appendix is not a part of the requirements of this NFPA Code, but is included for information purposes only. The term "shall" in this Appendix is used to indicate that if one chooses to use the Appendix, then, within the system described, the item is mandatory. Chapter 21 defines three levels of evacuation capabilities of the residents as a group (with staff assistance): (a) prompt; (b) slow; and (c) impractical. Chapter 21 also prescribes the fire safety protection requirements for each level of evacuation capability. This Appendix describes a method for determining evacuation capability. Separate subsystems are provided for: (a) Rating the evacuation capabilities of individual residents. (Step 1) (b) Computing the relative level of evacuation difficulty faced by the occupants of a given facility. This includes rating the Promptness of Response for the staff, introducing an adjustment for number of floors, and calculating an Evacuation Difficulty Score. Subsection defines three evacuation capabilities levels in terms of evacuation difficulty scores. Procedure for Determining Evacuation Capability STEP 1 - For each resident, complete one copy of Worksheet F1, Worksheet for Rating Residents. Follow the instructions on the Worksheet. Use the Instruction Manual for Rating Residents for further guidance and for definitions of terms. STEP 2 - For each facility complete one copy of Worksheet F-2, Worksheet for Calculating Evacuation Difficulty Score (E-Score). Follow the instructions on the Worksheet. Use the Instruction Manual for Calculating Evacuation Difficulty Score for further guidance and for definitions of terms. STEP 3 - Determine evacuation difficulty using the E-Score from Step 2 and the criteria of Instruction Manual for Rating Residents (Worksheet F-1) base ratings on commonly observed examples of poor performance. The Evacuation Difficulty Score has been designed to minimize speculation about how residents might perform in an actual fire emergency by basing ratings on already observed performance. Instead of speculating, raters who are not familiar enough with a resident to confidently provide ratings should consult with someone who has observed the resident on a daily basis. Due to the stress of a real fire emergency, some residents are not likely to perform as well as they are capable of doing. Therefore, ratings based on commonly observed examples of poor performance provide the best readily available indication of behavior that may be degraded due to the unusually stressful conditions of an actual fire. All persons naturally tend to be less capable on some days, and the ratings should be based on examples of resident performance on a typically "bad" day. Findings should not be based on rare instances of poor performance. Risk Factors (refer to Worksheet F-1, side 2) I. Risk of Resistance - means that there is a reasonable possibility that, during an emergency evacuation, the resident may resist leaving the group home. Unless there is specific evidence that resistance may occur, the resident should be rated as "minimal risk". Specific evidence of resistance means that staff have been required to use some physical force in the past. However, an episode of resistance should not be counted if it resulted from a situation that was different enough from a real fire emergency so that the incident

2 probably does not predict behavior in a real fire emergency. For example, an incident when a resident refused to leave his bedroom to visit his parents would probably not predict behavior in a real fire emergency and would not be counted as specific evidence. Resistance may be active (for example, the resident may have struck a staff member or attempted to run away) or passive (for example, the resident may have "gone limp" or hid from staff members). Mere complaining or arguing is not considered resistance. (a) Minimal Risk. This means that there is no specific evidence to suggest that the resident may resist an evacuation. (b) Risk of Mild Resistance. This means that there is specific evidence that the resident may mildly resist leaving the group residence. Examples of specific evidence that a resident should be rated in this category are as follows: (1) The resident has mildly resisted instructions from staff. Further, the resistance was brief or easily overcome by one staff member, and occurred in a situation similar enough to a fire emergency to predict that the behavior could recur during a fire emergency, or (2) The resident has hidden from the staff in a situation similar enough to a fire emergency to predict that the behavior could recur during a real fire emergency. However, once found, the resident offered no further resistance. (c) Risk of Strong Resistance. This means that the resident may offer resistance that requires the full attention of one or more staff members. Examples of specific evidence that suggest that a resident should be rated in this category are as follows: (1) The resident has struggled vigorously in a situation similar enough to a fire emergency to predict that the behavior could recur during a fire emergency, or (2) The resident has totally refused to cooperate in a situation that is similar enough to a fire emergency to predict that the behavior could recur during a real fire emergency, or (3) The resident has hidden in a situation that is similar enough to a fire emergency to predict that the behavior could recur during a real fire emergency. Moreover, once found, the resident continued to offer resistance. II. Impaired Mobility - means that the resident is physically limited in his or her ability to leave the home. The rating should reflect the present physical environment in the building where the resident lives and should be based on the resident lying awake on his/her bed. The resident is rated according to how easily he or she can leave, given the presence of physical barriers that hinder movement (such as stairs), the resident's ability to get out of bed or chairs he or she normally uses, and so forth. The resident should be given credit for being able to use devices that aid movement (for example, wheelchairs, walkers, crutches, and leg braces). However, the rater may give credit for such devices only if they are always available for an emergency evacuation. The resident should be rated on his or her ability to use the most accessible route out of the home. For example, a resident who is "self-starting" when he uses the back door, but who "needs limited assistance" to get out the front door would be rated as "selfstarting". The rater should test the resident when he/she is under the influence of any routine medication that slows the resident's movement. When the resident needs physical assistance to make a timely evacuation, the amount of assistance required is based on the categories defined below. Physical assistance mans that the staff member must use some strength to assist the resident. Guiding or directing the resident by giving gentle pushes or leading by the hand is not considered physical assistance. (a) Self-Starting - means that the resident is physically able to start and complete an evacuation without physical assistance. (b) Slow - means that the resident prepares himself or herself to leave and travels to the exit (or an area of refuge) at a speed significantly slower than normal. Specifically, the resident is rated "slow" if he/she cannot prepare him- or herself to leave, and then travel from his/her bedroom to the exit (or area of refuge) within a period of 90 seconds. (c) Needs Limited Assistance - means that the resident may require some initial or brief intermittent assistance, but can accomplish most of the evacuation without assistance. (The total time required to physically assist the resident should not exceed the amount of time typically required in the examples listed below.) The following are a few examples of capabilities that fall within this category: The resident would be physically able to start and complete an evacuation, except that: (1) The resident needs help to get into a wheelchair, or (2) The resident needs help to descend stairs in the building, or (3) The resident needs help to get out of bed, or

3 (4) The resident needs help to hope a door. (d) Needs Full Assistance or Very Slow - means that the resident needs "full assistance" or is "very slow" as defined in this section. Needs full assistance- The resident needs full assistance if either: (1) the resident may require physical assistance from a staff member during most of the resident's evacuation or (2) the total time required to physically assist the resident is equal to or greater than the time required in the examples below. The following are a few examples of capabilities that fall within this category: (1) The resident may need to be carried from the building. (2) The resident needs help to get into a wheelchair and must be wheeled out of the building. (3)The resident needs help to get into leg braces and needs help to descend steps. Very slow- The resident is rated very slow if the time necessary for the resident to prepare him- or herself to leave, and then travel from his/her bedroom to the exit, is so long that the staff cannot permit the resident to evacuate unassisted. Specifically, the resident is rated very slow if he/she cannot prepare him- or herself to leave, and then travel to the exit (or area of refuge), in 150 seconds. III. Impaired Consciousness - means that the resident could experience a partial or total loss of consciousness in a fire emergency. Unless there is specific evidence that loss of consciousness may occur during a fire emergency, the resident should be rated as "no significant risk." Specific evidence means that the resident has experienced some temporary impairment of consciousness of short duration (seconds or minutes) six or more times during the three months preceding the rating of the resident. Regardless of frequency, if there is specific evidence that loss of consciousness may be caused by the stress of a fire emergency, the resident should be rated as having impaired consciousness. An episode of partial loss of consciousness should be counted only if the impairment was severe enough to significantly interfere with the resident's ability to protect himself or herself. Do not count episodes where the loss of consciousness was the result of a temporary medical problem (e.g., a severe infection). (a) No Significant Risk - means that the resident is not subject to loss of consciousness or that the resident has had fewer than six episodes of consciousness loss (partial and total) during the three months preceding the ratings. (b) Partially Impaired - means that the resident has had at least six episodes of consciousness loss in the last three months, and that the most severe of these episodes was only a partial loss of consciousness; that is, the resident would still be able to participate somewhat in his or her own evacuation. Examples of specific evidence that a resident should be rated in this category include loss of consciousness result from mild (partial or petit mal) seizures, dizzy spells, intoxication, or any other partially incapacitating impairment of consciousness. (c) Totally Impaired - means that the resident has had at least six episodes of consciousness loss in the last three months, and that the most severe of these episodes was a total or severely incapacitating loss of consciousness; that is, the resident would require the full assistance of at least one staff member to get out of the building. Examples of specific evidence that a resident should be rated in this category include losses of consciousness resulting from severe (generalized or grand mal) seizures, fainting spells, intoxication, or other total or severely incapacitating loss of consciousness. IV. Need for Extra Help - means that there is specific evidence that more than one staff member may be needed to evacuate the resident. Specific evidence means that two or more persons have been previously needed to assist the resident, and that the resident could require assistance from two persons in a real fire emergency. When rating the resident on whether there is a need for additional assistance, the rater should disregard the presence of staff members who appear unusually strong or weak. (For example, a staff member who is exceptionally strong or an unusually small staff member would be disregarded when rating the resident on Need for Extra Help.) (a) Needs Only One Staff - means that there is no specific evidence that the resident might need help from two or more persons in a fire emergency.

4 (b) Needs Limited Assistance from Two Staff - means that the resident might require some initial or brief intermittent assistance from two persons, but will otherwise need help fro no more than one person. The following are a few examples of capabilities that fall within this category. The resident would require help from no more than one person except that: (1) The resident needs two persons to get into a wheelchair. (2) The resident needs two persons to descend stairs that are present in the building. (c) Needs Full Assistance from Two Staff. This means that the resident might require assistance from two persons during most of the resident's evacuation from the building. The following are a few examples of capabilities that fall within this category: (1) The resident may need to be carried from the building and this would require two persons, or (2) The resident would need two persons to get into a wheelchair and to get the wheelchair down a flight of stairs, or (3) The resident may vigorously resist an evacuation and two persons would be required to get the resident out of the building. V. Response to Instructions (Staff-Directed Evacuation) - means the resident's ability to receive, comprehend and follow through with simple instructions. Residents often do not respond equally well to all staff members. Therefore, residents should be rated on their responses to staff members whose directions they are least likely to follow. (a) Follows Instructions. This means that the resident can usually be depended on to receive, comprehend, remember and follow simple instructions. (b) Requires Supervision. This means that the resident is generally capable of following instructions, but is not dependable. Therefore, the resident may need to be guided, reminded, reassured or otherwise accompanied during his or her evacuation, but will not require the exclusive attention of a staff member. (For example, a staff member can simultaneously lead two or more residents who fit this classification.) This category includes elderly persons who sometimes show early signs of senile dementia or cerebral arteriosclerosis (for example, confusion, disorientation, frequent "misplacement" of possessions) and young children who cannot be depended on to follow through with instructions. Some examples of resident capabilities that fall within this category are as follows. The resident is generally capable of following instructions except that: (1) The resident is deaf or hearing impaired and sometimes misinterprets communications from staff using sign language, or (2) The resident sometimes forgets instructions after a brief period of time, or (3) The resident is sometimes distracted or confused and fails to follow through with instructions, or (4) The resident is sometimes groggy and may fail to listen carefully or follow through with instructions, or (5) The resident is sometimes uncooperative without apparent good reasons, or (6) The resident is elderly and sometimes becomes "lost" in a familiar place, or (7) The resident is a young child who may become frightened and not follow through with instructions. (c) Requires Considerable Attention or May Not Respond - means that the resident may fail to receive, understand or follow through with instructions; that is, the resident may not respond to instructions or general guidance. Therefore, the resident may require most of the attention of a staff member during his or her evacuation. Some examples of resident capabilities that fall within this category are as follows: (1) The resident sometimes does not understand simple instructions, or (2) The resident may not respond to instructions from a particular staff member, or (3) The resident is sometimes emotionally upset and is therefore unwilling to follow instructions, or (4) The resident is deaf or hearing impaired and the staff cannot communicate reliably with the resident, or

5 (5) The resident is very forgetful, easily confused or easily distracted. VI. Waking Response to Alarm - means that the fire alarm may fail to awaken the resident. Residents should be rated as "response probable" unless any of the following four conditions is true: (a) The building does not have an alarm system meeting the requirements of Chapter 21 or the alarm is not very loud where the resident sleeps (doors should be closed and barriers kept in place when testing the loudness of the fire alarm), or (b) Medication taken by the resident before retiring differs in type or amount (increased) from the medication taken for waking hours, or (c) The resident has a readily apparent hearing impairment or the resident removes his or her hearing aid when sleeping, or (d) There is some specific evidence that the resident may be an exceptionally sound sleeper. (Examples of specific evidence are: the resident did not wake up during some particularly loud clamor or racket and staff members have had to vigorously shake the resident to awaken him or her.) When any of the four conditions is true, then the resident should be rated as "response not probable" unless the resident's ability to wake up has been demonstrated. The demonstration of the resident's ability to wake up to the fire alarm should be conducted after the first half-hour of sleep and during the first three hours of sleep. Also, the resident's ability to wake up to the alarm should be demonstrated on two different nights under usual conditions (for example, without hearing aid, under usual medications, and so forth). Also, the resident should be alert enough to follow simple instructions within one minute of waking up. In order to avoid awakening other residents, a device that makes a sound that is similar to but not louder than the fire alarm may be used (for example, an alarm clock can be used instead of a bell alarm). (1) Response Probable - means that none of the four conditions is true for the resident or, when any of the conditions is true, the resident's ability to wake up has been demonstrated. (2) Response not Probable - means that one or more of the conditions is true for the resident, and that either the resident has not been tested for his or her ability to wake up to the fire alarm, or the resident failed to demonstrate his or her ability to wake up to the alarm. VII. Response to Fire Drills (Self-Directed Evacuation) - relates to the resident's ability to leave the building as demonstrated by the resident's performance during fire drills. It covers his or her ability to make decisions but does not relate to mobility, which is covered in a separate factor. For example, a resident may need assistance only in transferring from bed to wheelchair but otherwise can promptly initiate and complete an evacuation. Such a resident would get a "yes" for "Initiates and Completes Evacuation Promptly" (0 points) and would be rated "Needs Limited Assistance" on the "Impaired Mobility" factor (6 points). Components of a Self-Directed Evacuation - means there are three basic tasks that a resident must perform reliably and without instructions or supervision in order to receive the most favorable rating on this factor: (a) Initiates and Completes Evacuation Promptly - The resident must have demonstrated a proper response to an alarm or warning of a fire by starting and completing the evacuation without unnecessary delay. (b) Chooses and Completes Back-up Strategy - The resident must have demonstrated the ability to select an alternative means of escape or take other appropriate action if the primary escape route is blocked. (c) Stays at Designated Location - The resident must have demonstrated that he/she will stay at a designated safe location during fire drills. (The whereabouts of already evacuated residents needs to be confirmed to avoid dangerous return trips to look for residents who may have returned to buildings.) The resident shall be credited with being able to perform a task only when the resident has been specifically trained or instructed in the desired task and has demonstrated the desired response in at least three of the last four fire drills for which the skill was tested. When the skill has not been tested in four fire drills, the resident shall be credited only when the resident has demonstrated the desired response during the last two opportunities to test the skill. Ratings must be based on the resident's demonstrated performance. Any resident who has not been trained using fire drills must be given the higher scores. Residents must be rated assuming that a fire might find them in a common situation where they are least likely to respond well to an emergency. For most residents, this will be their evacuation ability after being awakened at night. The rating should not include difficulties in actually awakening the resident because of the large differences in how easy it is to wake up the same individual at various times of the night. (a) Initiates and Completes Evacuation Promptly. Some examples of resident capabilities that score "no" for this item are:

6 (1) The resident may not react to the alarm until alerted by a staff member. (2) The resident spends an excessive amount of time preparing to leave (for example, getting dressed, seeing what everyone else is doing). (3) The resident has a hearing impairment and therefore must be alerted by a staff member. (4) The resident is sometimes upset or confused and therefore may seek out a staff member before evacuating. (5) The resident will reliably start an evacuation, but is easily distracted and requires some supervision. (b) Chooses and Completes Back-up Strategy - Residents that score "no" on this item will be those unlikely to select a good course of action if the primary escape route cannot be used; that is, they have not been trained to find alternative escape routes, find an area of refuge or perform other appropriate action. An example of resident capabilities that score "no" for this item is: The resident lacks the conceptual ability to understand about fire hazards and blocked escape routes, and therefore needs supervision. (c) Stays at a Designated Location in a Safe Area - Some examples of resident's capabilities that score "yes" for this item are: (1) The resident has been specifically trained to remain at a designated location in a safe area, and has demonstrated this ability without the presence of staff members in three of the last four fire drills. (2) The resident is physically immobile, and therefore cannot leave the designated location. (3) The group home uses a motor vehicle (for example, a van or bus) or a building that is detached and remote from the home (for example, another house or a remote garage) as the designated location, and the resident has demonstrated in three of the last four fire drills that he or she will remain there without the presence of a staff member. (4) The resident may tend to wander, but a reliable resident has been assigned to keep the "wandering" resident at the designated location without using any force or coercion. Further, this arrangement has been demonstrated as effective in at least three of the last four fire drills. Some examples of residents that score "no" for this item are: (1) The resident has not been trained to stay at a designated location without any staff supervision. (2) The resident has been trained to stay without staff supervision at a designated location, but has failed to demonstrate this capability in three of the last four fire drills. Instruction Manual for Calculating Evacuation Difficulty Score (E-Score) (Worksheet F-2) - Requirements for Using the Evacuation Difficulty Score (E-Score). While the use of the Evacuation Difficulty Score allows determination of the level of fire safety need for a variety of staff and resident combinations, the system is valid only when the following underlying requisites are satisfied. (a) Has a Protection Plan Been Developed and Written and Have All Staff Members Counted in the Calculation of E-Scores Been Trained in its Implementation? Regardless of the staff's everyday competencies, they cannot be relied on to innovate effective life safety actions under the extreme stress and time limitations of an actual fire emergency. Regardless of the building's protection features, staff must have a valid and practiced plan of action that can be immediately put into effect in an emergency. The protection plan should include the following features: (1) a description of all available evacuation, escape and rescue routes and the procedures and techniques needed to evacuate all the residents using the various routes, and (2) the fundamental knowledge about fire growth, containment and extinguishment needed to make reasonable judgments about action priorities and viable egress routes. (b) Is the Total Available Staff at any Given Time Able to Handle the Individual Evacuation Needs of Each Resident Who May Be in the Board and Care Home? In a well-protected building, it would be possible to have an E-Score which is passing in relation to the rating values for the fire protection features of the building, and still not have the total situation acceptable under this system. This would be the case where a

7 resident is present who requires assistance from two staff members, but only one staff member is present. Thus, a facility must not only have a passing E-Score, but the situation must be such that every resident can be evacuated by available staff. Exception : This requirement is waived when the following conditions are true: (1) The building meets the criteria for impractical level of evacuation difficulty; and (2) For any time when the question is answered "no": a. The resident whose evacuation needs cannot be handled is in a bedroom or other room that provides adequate refuge from fire outside the room, and b. There is at least one staff member present who can close the door to the room. Example: A very heavy resident is in a building meeting the criteria for impractical level of evacuation difficulty with one staff member who cannot transfer the resident from his bed to his wheelchair. Although the staff member cannot meet all the resident's evacuation assistance needs, the problem arises only when the resident is in his bedroom and the bedroom provides adequate refuge. (c) Can Every Staff Member Counted in the Calculation of E-Scores Participate Meaningfully in the Evacuation of Every Resident? For example, a staff member, due to his or her own disability, may be unable to assist one or more physically disabled residents and, therefore, cannot be included in the calculation of the E-Score. However, if a staff member's disability does not limit his or her ability to assist the residents, then the staff member may be included. (d) Are All Staff Members Counted in the Calculation of E-Scores Required to Remain in the Dwelling Unit with Only the Exceptions Listed in the Instruction Manual? The procedure described in this Appendix for calculating an Evacuation Difficulty Score is based upon the assumption that the facility is always staffed when residents are in the building except as described below. Un-staffed buildings, not covered by these Exceptions, may be assigned an evacuation capability level based on the demonstrated ability of the residents to meet the criteria of without staff assistance. The Exceptions are as follows: (1) Residents who receive only the most favorable ratings on the Worksheet for Rating Residents may be present in the dwelling unit without the presence of staff members. (2) A staff member may be at a location outside of the dwelling unit when his/her ability to respond to a fire emergency from the location is roughly equivalent to his/her response ability from within the dwelling unit. In determining equivalency, the regulatory authority should consider: a. whether the alarm meets the minimum loudness criteria (see the Instruction Manual for Calculating Evacuation Difficulty Score) at the locations outside the dwelling unit or whether another staff member who is required to remain in the dwelling unit can immediately notify the outside staff member of a fire emergency; b. travel time to the dwelling unit; c. detection of fire cues (e.g., smoke, noises) from the locations outside the dwelling unit; and d. whether the staff member will be immediately notified about which area has the fire emergency, if the outside staff member is required to report to fire emergencies in more than one dwelling unit or fire zone. The authority having jurisdiction can grant partial credit (not to exceed the Delay of Response score that the staff member would receive when required to remain in the dwelling unit) for staff members who are permitted to be at locations outside the dwelling unit, but who have an ability to respond promptly. (e) Were at Least Six Fire Drills Conducted in the Last Year? Any home in operation for less than one year should have had as many fire drills as months of operation to meet the requirement for proper number of fire drills. (Requirement is for 12 drills the first year and six all other years.) Worksheet for Calculating the Evacuation Difficulty Score (E-Score) (Worksheet F-2) I. Areas of Application of Evacuation Difficulty Score -

8 (a) Small Facilities (housing not greater than 16 residents). The evacuation difficulty score is based on all of the housed residents and the available staff measured in accordance with the criteria for evaluating residents and staff in this instruction manual. (b) Large Facilities (housing greater than 16 residents). The evacuation difficulty score may be calculated on the basis of individual fire/smoke zones. The procedure providing the better, i.e., (lower), evacuation difficulty score may be used. A fire/smoke zone is a portion of the building separated from all other portions of the building by building construction having at least 1-hour fire resistance and/or smoke barrier conforming to the requirement of Section 6-3 of the Life Safety Code for smoke barriers of at least 20-minute fire resistance. Zoning of the facility is also permitted in non-fire-resistive sprinklered buildings provided the construction separating one zone from another is sound and smoke resistant. If a building is zoned, each zone shall be separately evaluated. Its evacuation difficulty score is based on the residents of that zone and the staff that is available to that zone in accordance with the staff availability criteria in this instruction manual. When the area of application is by zone, a separate evaluation is to be made of zones that include common use spaces where the residents of more than one zone congregate for meals, recreation, or other purposes. In such cases, adjust the resident evacuation assistance scores as appropriate to reflect the needs residents would have under such conditions. II. Finding Staff Shift Score (Worksheet F-2B) - If it is not obvious which time period has the highest E-Value, complete a separate worksheet for all candidate time periods and use the one having the highest E-Value. Alarm Effectiveness- This factor concerns whether smoke detector-activated alarm devices are loud enough to dependably alert staff to a fire emergency. (a) Assured. To be rated "assured", the alarm shall be "easily noticeable" in all locations where staff are allowed to go, regardless of their ratings on the promptness of response factor. To be "easily noticeable" the alarm shall be a minimum of 55 dba measured at ear level. However, in order to be "easily noticeable", the authority having jurisdiction may require the alarm to be louder than 55 dba where background noise interferes with alarm audibility. For example, the alarm may need to be more than 55 dba in order to be loud enough to be heard over the noise of washing machine in the laundry, a television in the living room, and so forth. In addition, if there are staff who are allowed to sleep, the alarm shall be a minimum of 70 dba measured at "pillow" level in any area where they may be asleep. The alarm must be activated by one or both of the following: 1. Smoke detectors. 2. Sprinkler system. If the facility has smoke detectors meeting the requirements of Chapter 21, the smoke detectors must activate the alarm. If the facility has a sprinkler system whose fire safety properties are considered in the fire safety evaluation of the building, activation of the sprinkler system must activate the alarm. (b) Not Assured. The alarm does not satisfy the conditions specified under "Assured". The loudness of the alarm is determined with doors, normally closed during the time period being rated, being closed, and with any other barriers that reduce the loudness of the alarms in place. (c) Staff Availability. This factor concerns whether there are circumstances when staff may be less able to respond appropriately or may be delayed in their response to a fire emergency. Staff members shall be included in the ratings only if they are required to remain within the residence,* if they sleep less than 100 ft (30 m) from all locations in the portion of the facility being evaluated, and/or their travel time to any location in the portion of the facility being evaluated does not exceed 1 minute. *Exceptions to this requirement are listed in the Requirements for Using the Evacuation Difficulty Index. (a) Standby or Asleep - means that the staff member does not have specific duties that assure an immediate response to the alarm, but that the staff member is otherwise available to assist in a timely manner. This category includes live-in staff who may be asleep, showering, or otherwise unable to respond immediately. (b) Immediately Available - means that the staff member is required to be available to offer immediate assistance, but is not required to remain in close proximity to the residents. For example, the staff member would be allowed to wash clothes or do bookkeeping. (c) Immediately Available and Close-by - means that the staff member, in addition to satisfying the requirement for immediately available, is also required to remain in close proximity to the residents except for brief periods of time.

9 If the home is a large facility and has multiple fire/smoke zones, some staff may have responsibilities for residents outside the fire/smoke zone being evaluated. If their duties include rescue of residents in the fire zone being evaluated, they may be assigned partial or full promptness of response scores. The authority having jurisdiction shall assign the points based on the proximity of the staff members to the zone and the nature of their duties in a fire emergency. This credit will be given only if there is a smoke detection system that will alert the staff member and a system or procedure for promptly informing the staff member of the general location of the fire. Residents may be assigned responsibilities similar to staff in assisting other residents during fire emergencies. The authority having jurisdiction may assign these residents up to 8 Promptness of Response points based on their capabilities and responsibilities. III. Finding the Home's Evacuation Difficulty Score (Worksheet F-2C). Vertical Distance from Bedrooms to Exits - This factor concerns the increased risk resulting from resident bedrooms that are located where residents must travel through another floor in order to get outside of the small dwelling. Certain critical terms are defined as follows: Direct Exit - means that there is no more than one step between the inside of the dwelling and either (1) ground level outside or (2) a level area outside the dwelling that is at least 32 sq ft (3.0 sq m). This level area might be a porch or a stairway landing. When the vertical distance is greater than one step, a ramp may be used to satisfy this criterion. Vertical Distance - refers to the greatest number of floors that separates any resident bedroom from its nearest direct exit. (a) All Bedrooms on Floors with Direct Exits - means that every room where residents sleep is on a floor with at least one direct exit. Some examples of buildings that fall within this category follow: (1) A one-story house without bedrooms in the basement, or (2) A two-story house without bedrooms on the second floor, or (3) A split-level house with direct exits at each level, or (4) A two-story house with bedrooms on the second floor that has an exterior stairway from the second floor with a landing at the second floor which is greater than 32 sq ft (3.0 sq m). (b) Any Bedroom One Floor from Exit - means that there is at least one room where residents sleep where the shortest vertical distance to a direct exit is one floor. Some examples of buildings that fall within this category follow: (1) A two-story building with bedrooms on the second floor and/or the basement, or (1) A one-story house where all the exits have stairs that lead to grade, without a landing, or porch of 32 sq ft (3.0 sq m). (c) Any Bedroom Two or More Floors from Exit - means that there is at least one room where residents sleep where the shortest vertical distance to a direct exit is two or more floors. Some examples of buildings that fall within this category follow: (1) A three-story house with bedrooms on the third floor and no exterior fire escape, or (2) A three-story house with bedrooms on the third floor and a fire escape, but the landing to the fire escape is less than 32 sq ft (3.0 sq m). If the board and care home is located in an apartment house and the unit containing the group home requires ascending or descending stairs to go from any bedroom to the exit to the corridor, assign a score of 1.2 for Vertical distance from Bedrooms to Exits. Note: This special scoring of this rare type of apartment is not noted on the Worksheet. In all other apartments, the score for Vertical Distance from Bedrooms to Exits - equals 1 **Forms and /or a copy of the adopted appendix f are available from the Department of Mental Health, Lewis Cass Building, Lansing, MI 48913, at cost. A copy of appendix f may also be obtained from the National Fire Protection Association Library, Battermarch Park, P. O. Box 9101, Quincy, Massachusetts , A prepaid fee may be required by the national fire protection association for a copy of appendix f. A price quote for copying of these pages may be obtained from the national fire protections association.

C. None (No sprinkler system) K3 E. NUMBER OF BEDS CERTIFIED FOR MEDICAID

C. None (No sprinkler system) K3 E. NUMBER OF BEDS CERTIFIED FOR MEDICAID DEPARTMENT OF HEALTH AND HUMAN SERVICES CENTERS FOR MEDICARE & MEDICAID SERVICES FIRE SAFETY SURVEY REPORT - 2000 LIFE SAFETY CODE Intermediate Care Facilities for the Mentally Retarded LARGE PART I Figure

More information

Agency for Health Care Administration

Agency for Health Care Administration Page 1 of 100 FED - K0000 - INITIAL COMMENTS Title INITIAL COMMENTS CFR Type Memo Tag FED - K9999 - FINAL OBSERVATIONS Title FINAL OBSERVATIONS CFR Type Memo Tag FED - KA100 - General Requirements - Other

More information

Agency for Health Care Administration

Agency for Health Care Administration Page 1 of 51 FED - K0000 - INITIAL COMMENTS Title INITIAL COMMENTS CFR Type Memo Tag FED - K0130 - MISCELLANEOUS Title MISCELLANEOUS OTHER LSC DEFICIENCY NOT ON 2786 FED - K9999 - FINAL OBSERVATIONS Title

More information

GROUP SR SPECIAL RESIDENCE (ASSISTED SELF-PRESERVATION) OCCUPANCIES

GROUP SR SPECIAL RESIDENCE (ASSISTED SELF-PRESERVATION) OCCUPANCIES [B] APPENDIX SR GROUP SR SPECIAL RESIDENCE (ASSISTED SELF-PRESERVATION) OCCUPANCIES The provisions contained in this appendix are adopted by the Building Codes Division of the State of Oregon SECTION SR101

More information

Safety And Fire Prevention

Safety And Fire Prevention Safety And Fire Prevention A guide to help Direct Support Professionals prepare for, respond to and prevent emergencies in a licensed residential home setting. Outcomes: Direct Support Professionals (DSP)

More information

Agency for Health Care Administration

Agency for Health Care Administration Page 1 of 92 FED - K0000 - INITIAL COMMENTS Title INITIAL COMMENTS Type Memo Tag FED - K9999 - FINAL OBSERVATIONS Title FINAL OBSERVATIONS Type Memo Tag FED - KA100 - General Requirements - Other Title

More information

GROUP SR SPECIAL (ASSISTED SELF-PRESERVATION) OCCUPANCIES

GROUP SR SPECIAL (ASSISTED SELF-PRESERVATION) OCCUPANCIES [B] APPENDIX SR GROUP SR SPECIAL (ASSISTED SELF-PRESERVATION) OCCUPANCIES The provisions contained in this appendix are adopted by the Building Codes Division of the State of Oregon. SECTION SR101 GENERAL

More information

EMERGENCY EVACUATION POLICY FOR 100 CHEROKEE STREET BUILDING

EMERGENCY EVACUATION POLICY FOR 100 CHEROKEE STREET BUILDING EMERGENCY EVACUATION POLICY FOR 100 CHEROKEE STREET BUILDING In the event of a fire or other emergency, seconds count. The safe, orderly and prompt evacuation of building occupants depends on having the

More information

DEALING WITH FIRE SAFETY

DEALING WITH FIRE SAFETY DEALING WITH FIRE SAFETY Personal Care Homes And Assisted Living Facilities Presented by: Harold D. Hicks, P.E., FSFPE Fire Protection Engineer 1 Atlantic Code Consultants 2 Our Objectives Recognize the

More information

Emergency Evacuation Plan

Emergency Evacuation Plan Emergency Evacuation Plan A Guide to Help Episcopal Churches Reduce Risk to People and Property in the Event of a Fire 2000 Church Risk Management Services INDEX I. Emergency Action Planning General list

More information

RESIDENTIAL CARE USER GUIDE UPDATES TO MANITOBA BUILDING/FIRE CODE:

RESIDENTIAL CARE USER GUIDE UPDATES TO MANITOBA BUILDING/FIRE CODE: RESIDENTIAL CARE USER GUIDE UPDATES TO MANITOBA BUILDING/FIRE CODE: Manitoba Regulation 221/2015 and Manitoba Regulation 222/2015 DATE: MARCH 17, 2016 1. INTRODUCTION On April 1, 2016, new building and

More information

5123: information. The graphic plan shall include, but may not be limited to: (a) A primary and secondary means of exit from each floor;

5123: information. The graphic plan shall include, but may not be limited to: (a) A primary and secondary means of exit from each floor; ACTION: Original DATE: 09/30/2005 1:17 PM 5123:2-3-11 Fire safety and emergency response plans. (A) Purpose The purpose of this rule is to ensure the safety of individuals residing in residential facilities

More information

DUQUESNE UNIVERSITY EMERGENCY EVACUATION GUIDELINES

DUQUESNE UNIVERSITY EMERGENCY EVACUATION GUIDELINES Prepared by: Environmental Health and Safety DUQUESNE UNIVERSITY EMERGENCY EVACUATION GUIDELINES TABLE OF CONTENTS Page 1.0 General Information 1 2.0 Responsibilities 2 3.0 Reporting Fires and Other Emergencies

More information

Guidance for writing a Personal Emergency Evacuation Plan (PEEP)

Guidance for writing a Personal Emergency Evacuation Plan (PEEP) Guidance for writing a Personal Emergency Evacuation Plan (PEEP) If assistance with escape is required, the extent of such assistance should be identified in the PEEP i.e. the number of assistants and

More information

Fire evacuation drill

Fire evacuation drill European guideline (handbook) Fire evacuation drill (draft document) Ver: 2010-06-02 Prepared by Aleš Jug, Slovenia Related guideline: CFPA E: 19_2009 Fire safety engineering concerning evacuation from

More information

Emergency Planning for Institutional Facilities

Emergency Planning for Institutional Facilities Emergency Planning for Institutional Facilities Pacific ADA Emergency Preparedness Webinars Presented by: Kimberly Paarlberg, ICC Based on the 2015 edition of the International Building Code (IBC) and

More information

WORKSHEET 2-1 THE MANITOBA RESIDENTIAL OCCUPANCY FIRE RISK INDEX FIRE SAFETY PARAMETER VALUES

WORKSHEET 2-1 THE MANITOBA RESIDENTIAL OCCUPANCY FIRE RISK INDEX FIRE SAFETY PARAMETER VALUES 1 WORKSHEET 2-1 THE MANITOBA RESIDENTIAL OCCUPANCY FIRE RISK INDEX FIRE SAFETY PARAMETER VALUES TABLE 2.1 CONSTRUCTION OF STRUCTURAL MEMBERS AND FLOOR AND ROOF (1) ASSEMBLIES (Applies to each fire zone)

More information

For additional information regarding R-3.1 residential care facilities please contact (951)

For additional information regarding R-3.1 residential care facilities please contact (951) Riverside County Fire Department Fire/Life Safety Inspection Division Riverside Office: 2300 Market St., Ste. 150, Riverside, CA 92501 Ph. (951) 955-4823 Fax (951) 955-4886 Palm Desert Office: 77-933 Las

More information

Section 3. Preparedness. Shelton School District Emergency Response Plan

Section 3. Preparedness. Shelton School District Emergency Response Plan Section 3 Preparedness Preparedness Preparedness: Developing a School-Based Emergency Plan...3.1 Importance of Preparedness...3.1 Organization of this Preparedness Section...3.1 Developing a Site-Specific

More information

Report on First Revisions with Statement June 2014 NFPA 101

Report on First Revisions with Statement June 2014 NFPA 101 101 FR6005 SAF-BCF (32.2.1.1.2) Recommendation: 32.2.1.1.2 Where there are sleeping accommodations for more than 16 residents are provided, the occupancy shall be classified as a large facility in accordance

More information

Policy for Safe Evacuation of Persons with Disabilities

Policy for Safe Evacuation of Persons with Disabilities Policy for Safe Evacuation of Persons with Disabilities 1. Policy Statement The London School of Economics is committed to promoting access for people who have a disability or long-term medical condition.

More information

RULES OF THE TENNESSEE DEPARTMENT OF INTELLECTUAL AND DEVELOPMENTAL DISABILITIES OFFICE OF LICENSURE CHAPTER LIFE SAFETY LICENSURE RULES

RULES OF THE TENNESSEE DEPARTMENT OF INTELLECTUAL AND DEVELOPMENTAL DISABILITIES OFFICE OF LICENSURE CHAPTER LIFE SAFETY LICENSURE RULES RULES OF THE TENNESSEE DEPARTMENT OF INTELLECTUAL AND DEVELOPMENTAL DISABILITIES OFFICE OF LICENSURE CHAPTER 0465-02-04 LIFE SAFETY LICENSURE RULES TABLE OF CONTENTS 0465-02-04-.01 Life Safety Requirements

More information

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge. 2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge. Exception: Manual fire alarm boxes are not required where the building is

More information

Section 9 THE GUIDELINES FOR DEVELOPING AN EVACUATION PLAN FOR INDIVIDUALS WITH DISABILITIES. Shelton School District Emergency Response Plan

Section 9 THE GUIDELINES FOR DEVELOPING AN EVACUATION PLAN FOR INDIVIDUALS WITH DISABILITIES. Shelton School District Emergency Response Plan Section 9 THE GUIDELINES FOR DEVELOPING AN EVACUATION PLAN FOR INDIVIDUALS WITH DISABILITIES Introduction.8.1 Buildings with Inaccessible Exits for Individuals with Disabilities...8.1 Definitions...8.1

More information

Residential Based Care Facility Guidelines

Residential Based Care Facility Guidelines Moreno Valley Fire Department Fire Prevention Bureau Residential Based Care Facility Guidelines Approved and Authorized By: Randall Metz, Fire Marshal Issued: January 1, 2011 Residential Based Care Facilities

More information

Reviewed: DD Month Emergency Evacuation of People with a Disability Options Matrix for Developing a PEEP

Reviewed: DD Month Emergency Evacuation of People with a Disability Options Matrix for Developing a PEEP Safety Office Reviewed: 17 July 2012 Reviewed: DD Month Emergency Evacuation of People with a Disability Options Matrix for Developing a PEEP The following matrix includes most disability types and recommends

More information

FIRE SAFETY AND EVACUATION PLANNING FOR ASSISTED LIVING FACILITIES AND NURSING HOMES

FIRE SAFETY AND EVACUATION PLANNING FOR ASSISTED LIVING FACILITIES AND NURSING HOMES FIRE SAFETY AND EVACUATION PLANNING FOR ASSISTED LIVING FACILITIES AND NURSING HOMES West Metro Fire Rescue Life Safety Division 433 South Allison Parkway Lakewood, Colorado 80226 (303) 989-4307 Fax (303)

More information

EVACUATION PLAN FOR THE CLINTON COUNTY OFFICE BUILDING

EVACUATION PLAN FOR THE CLINTON COUNTY OFFICE BUILDING EVACUATION PLAN FOR THE CLINTON COUNTY OFFICE BUILDING James R. Langley, Jr. Chairman, Clinton County Legislature 2002 Table of Contents Section I: General Considerations and Planning Guidelines Introduction

More information

ICC CODE CORNER 2015 International Fire Code

ICC CODE CORNER 2015 International Fire Code PART II GENERAL SAFETY PROVISIONS CHAPTER 4 EMERGENCY PLANNING AND PREPAREDNESS SECTION 401 GENERAL 401.1 Scope. Reporting of emergencies, coordination with emergency response forces, emergency plans and

More information

FIRE INSPECTION GUIDELINES FOR FOSTER GROUP HOME PARENTS Effective June 1, 2002, Update September 2011

FIRE INSPECTION GUIDELINES FOR FOSTER GROUP HOME PARENTS Effective June 1, 2002, Update September 2011 HCFMO Harris County Fire Marshal M.S. Montgomery Fire Marshal FIRE INSPECTION GUIDELINES FOR FOSTER GROUP HOME PARENTS Effective June 1, 2002, Update September 2011 EFFECTIVE JANUARY 1, 2007 These guidelines

More information

MCCMH MCO Policy FIRE SAFETY IN RESIDENTIAL SETTINGS Date: 5/04/11. Definitions

MCCMH MCO Policy FIRE SAFETY IN RESIDENTIAL SETTINGS Date: 5/04/11. Definitions MCCMH MCO Policy 3-031 FIRE SAFETY IN RESIDENTIAL SETTINGS Date: 5/04/11 IV. Definitions A. Emergency Kit Bag A collection of items that are taken by group home staff, if possible, during each emergency/evacuation,

More information

Residential Care Facilities Requirements

Residential Care Facilities Requirements Development Services Department Building Division 311 Vernon Street Roseville, California 95678-2649 Residential Care Facilities Requirements SUBMITTAL REQUIREMENTS: Note: These requirements are in addition

More information

CHAPTER LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE, 2000 EDITION SECTIONS

CHAPTER LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE, 2000 EDITION SECTIONS CHAPTER 23.45 LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE, 2000 EDITION SECTIONS 23.45.100 Local Amendments To The International Fire Code, 2000 Edition 23.45.102.1 Construction and Design Provisions

More information

Patrick County Horizons Jeb Stuart Hwy. Stuart, Va

Patrick County Horizons Jeb Stuart Hwy. Stuart, Va Patrick County Horizons 24141 Jeb Stuart Hwy. Stuart, Va. 24171 Emergency Preparedness Plan Severe Weather/Earthquake/Building Damage/Fire/Missing Person Policy: Per page 22 of the PCS licensure manual:

More information

Riverside County Fire Department Office of the Fire Marshal Market St., Ste. 150, Riverside, CA Ph. (951) Fax (951)

Riverside County Fire Department Office of the Fire Marshal Market St., Ste. 150, Riverside, CA Ph. (951) Fax (951) Riverside County Fire Department Office of the Fire Marshal 2300 Market St., Ste. 150, Riverside, CA 92501 Ph. (951) 955-4777 Fax (951) 955-4886 Guideline Title: Residentially Based Care Facilities Group

More information

LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2006 EDITION

LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2006 EDITION CHAPTER 23.45 Sections LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2006 EDITION 23.45.100 Local amendments to the International Fire Code, 2006 Edition... 2 23.45.102.1 Construction and design provisions...

More information

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD July 1, 2010 SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD LICENSED CARE FACILITIES SCOPE: This standard provides requirements for licensed care facilities known as for the Elderly with seven

More information

Appendix D. Emergency Evacuation for Persons with Disabilities

Appendix D. Emergency Evacuation for Persons with Disabilities Appendix D Emergency Evacuation for Persons with Disabilities Background This appendix provides a general guideline of evacuation procedures for persons whose disabilities could make exiting difficult

More information

RAMBLER PARK FIRE SAFETY INFORMATION

RAMBLER PARK FIRE SAFETY INFORMATION RAMBLER PARK FIRE SAFETY INFORMATION Parmenter Realty Partners 7557 Rambler Rd. Dallas, Texas 75231 214-373-9561 214-373-9620 (fax) RAMBLER PARK RAMBLER PARK FIRE SAFETY INFORMATION II. Objective To provide

More information

Emergency Action Plan

Emergency Action Plan Emergency Action Plan Company Name Current as of Company Address Phone Number Contents EMERGENCY ACTION PLAN 2 SCOPE OF THE PLAN 2 Emergency Plan Coordinators 2 First Aid and CPR certified employees 2

More information

SCALES NW EMERGENCY ACTION PLAN

SCALES NW EMERGENCY ACTION PLAN Purpose Each SCALES NW, INC location shall have a written Emergency Action Plan, appropriate to the hazards of the workplace, in order to respond to an emergency that may require rescue or evacuation.

More information

Emergency Action Plans (OSHA ) Abstract. Introduction. Emergency Action Plan (EAP) Elements of an EAP

Emergency Action Plans (OSHA ) Abstract. Introduction. Emergency Action Plan (EAP) Elements of an EAP 1 Fire Protection Report Number: FP-45-10 Release Date: July 12, 2000 Section Title: Emergency Management Abstract OSHA 1910.38 requires employers of more than ten people to establish a written emergency

More information

Unit 2 Fire Safety (Zone 2)

Unit 2 Fire Safety (Zone 2) IFE Level 3 Diploma in Fire Safety and Fire Science Unit 2 Fire Safety (Zone 2) Examiner Report March 2017 Introduction 21% of the candidates that sat the examination attained a pass. Candidates did not

More information

Learn not to Burn kindergarten. Introduction A FIRE SAFETY EDUCATION PROGRAM FOR KINDERGARTENERS

Learn not to Burn kindergarten. Introduction A FIRE SAFETY EDUCATION PROGRAM FOR KINDERGARTENERS Introduction Introduction A FIRE SAFETY EDUCATION PROGRAM FOR KINDERGARTENERS Welcome to the National Fire Protection Association Learn Not to Burn (LNTB) family. Learn Not to Burn has served as the pillar

More information

SHREWSBURY COLLEGE EMERGENCY PROCEDURES. Firearm and Weapon Attacks

SHREWSBURY COLLEGE EMERGENCY PROCEDURES. Firearm and Weapon Attacks SHREWSBURY COLLEGE EMERGENCY PROCEDURES Firearm and Weapon Attacks Attacks involving firearms and weapons are very rare but it is important to be prepared to cope with such an incident. In the event of

More information

FACILITY OF EMERGENCY PLAN. (Template)

FACILITY OF EMERGENCY PLAN. (Template) FACILITY OF EMERGENCY PLAN (Template) Date: Table of Contents RECORD OF AMENDMENTS... 2 DISTRIBUTION LIST... 3 EMERGENCY PLAN AUTHORIZATION... 4 INTRODUCTION... 5 PURPOSE... 6 AIM... 6 ACTIVATING AND IMPLEMENTING

More information

Some information I have read tells me to evacuate immediately in case of fire. Fire In Your Residential Building. To Go?? To Stay??

Some information I have read tells me to evacuate immediately in case of fire. Fire In Your Residential Building. To Go?? To Stay?? Fire In Your Residential Building To Go?? or To Stay?? Your safety depends on the right decision. Your fire safety is your responsibility! If you live in an apartment or condominium, your safety also depends

More information

Table of Contents CHAPTER 10 ADMINISTRATIVE RULES FOR CERTIFICATION OF CHILD CARE FACILITIES FIRE STANDARDS FOR FAMILY CHILD CARE HOME

Table of Contents CHAPTER 10 ADMINISTRATIVE RULES FOR CERTIFICATION OF CHILD CARE FACILITIES FIRE STANDARDS FOR FAMILY CHILD CARE HOME Table of Contents CHAPTER 10 ADMINISTRATIVE RULES FOR CERTIFICATION OF CHILD CARE FACILITIES FIRE STANDARDS FOR FAMILY CHILD CARE HOME Section No. Subject Page No. 1 Authority and Purpose 10-1 2 Definitions

More information

SANTA CLARA COUNTY Winchester Blvd., Los Gatos, CA (408) (408) (fax)

SANTA CLARA COUNTY Winchester Blvd., Los Gatos, CA (408) (408) (fax) FIRE DEPARTMENT SANTA CLARA COUNTY 14700 Winchester Blvd., Los Gatos, CA. 95032-1818 (408) 378-4010 (408) 378-9342 (fax) www.sccfd.org STANDARD DETAILS & SPECIFICATIONS Spec No C-4 Rev. Date 03/10/10 SUBJECT:

More information

Emergency Procedures for Persons Requiring Assistance in Evacuation

Emergency Procedures for Persons Requiring Assistance in Evacuation Emergency Procedures for Persons Requiring Assistance in Evacuation This document is available in an alternate format, upon request. Developed by Health and Safety and the Office of Human Rights, Equity

More information

West International House Fire Plan Updated: September 14, 2010 By: Resident Manager

West International House Fire Plan Updated: September 14, 2010 By: Resident Manager West International House Fire Plan Updated: September 14, 2010 By: Resident Manager 1 Section 1 A. West International House 1. Staff Resident Director: INTO Student Services Manager: in building from 8

More information

A SURVEY OF OCCUPANT RESPONSE TOWARDS AN AUDIBLE FIRE ALARM

A SURVEY OF OCCUPANT RESPONSE TOWARDS AN AUDIBLE FIRE ALARM Int. Journal for Housing Science, Vol.33, No.4 pp. 249-258, 2009 Published in the United States A SURVEY OF OCCUPANT RESPONSE TOWARDS AN AUDIBLE FIRE ALARM L. T. Wong, N. K. Fong and W. H. Sui Department

More information

TG FIRE DRILLS. Office of the Fire Marshal and Emergency Management

TG FIRE DRILLS. Office of the Fire Marshal and Emergency Management FIRE DRILLS Office of the Fire Marshal and Emergency Management Preface This guideline updates TG-01-2004 published in October 2004. Portions of the guideline have been changed to reflect the current requirements

More information

Life Safety - Means of Egress/Exits NFPA 101

Life Safety - Means of Egress/Exits NFPA 101 Life Safety - Means of Egress/Exits NFPA 101 Properly designed exits provide a safe path of escape from a fire or other emergency environment. The means of egress (exits) should be arranged to permit all

More information

2007 CBC & CFC Residential Care Facility Requirements (24 hour care only)

2007 CBC & CFC Residential Care Facility Requirements (24 hour care only) 2007 & CFC Residential Care Facility Requirements (24 hour care only) Occupancy Construction Smoke Barrier I-1 Bedridden 7+non- Ambs Or bed- Ridden R-4 7+ambs (May have 6 nonambs or 6 bedridden) R-3.1

More information

Fire Evacuation Procedure Stroud Campus

Fire Evacuation Procedure Stroud Campus South Gloucestershire and Stroud College Fire Evacuation Procedure Stroud Campus If you would like this document in an alternate format Please contact the Human Resources Department Prepared by: Job Title/Role:

More information

Evacuation Policy for People with Special Needs

Evacuation Policy for People with Special Needs Evacuation Policy for People with Special Needs Reviewed By David Neild Last Reviewed date Autumn 2016 Next Review Date Autumn 2017 Headlands School Evacuation Policy For People With Special Needs Arrangements

More information

CHAPTER 7 ALTERATIONS LEVEL

CHAPTER 7 ALTERATIONS LEVEL CHAPTER 7 ALTERATIONS LEVEL 2 SECTION 701 GENERAL 701.1 Scope. Level 2 alterations as described in Section 404 shall comply with the requirements of this chapter. Exception: Buildings in which the reconfiguration

More information

EMERGENCY PREPAREDNESS: EVACUATIONS

EMERGENCY PREPAREDNESS: EVACUATIONS GUIDELINE I. EMERGENCY PREPAREDNESS: EVACUATIONS 1.0 PURPOSE 1.1 To provide guidance for the safe and orderly evacuation of faculty, staff, students and visitors to the University of Pennsylvania campus

More information

EMERGENCY EVACUATION PLAN

EMERGENCY EVACUATION PLAN UCL ESTATES & FACILITIES DIVISION Construction Maintenance & Fire Safety UNIVERSITY COLLEGE LONDON EMERGENCY EVACUATION PLAN Regulatory Reform (Fire Safety) Order 2005 Name & Address of Building: Occupying

More information

First Revision No NFPA [ Global Input ] Submitter Information Verification. Committee Statement

First Revision No NFPA [ Global Input ] Submitter Information Verification. Committee Statement of 43 10/20/2015 4:02 PM First Revision No. 2035-NFPA 101-2015 [ Global Input ] To 14.3.4.4.1, add an item (4) to read: (4) Carbon monoxide detectors shall be installed centrally located within occupiable

More information

PERSONAL EMERGENCY EVACUATION PLANS (PEEP s)

PERSONAL EMERGENCY EVACUATION PLANS (PEEP s) PERSONAL EMERGENCY EVACUATION PLANS (PEEP s) 1 2 Example Peep 3 Peep Proforma 4. County Hall visitors PEEP Introduction A PEEP is a record of the arrangements needed to accommodate and evacuate a person

More information

Fire Evacuation Procedure WISE Campus

Fire Evacuation Procedure WISE Campus South Gloucestershire and Stroud College Fire Evacuation Procedure WISE Campus If you would like this document in an alternate format Please contact the Human Resources Department Prepared by: Job Title/Role:

More information

Emergency Evacuation Procedures

Emergency Evacuation Procedures Emergency Evacuation Procedures Preparing for an Evacuation Know your building or classroom s floor plan. Know where the doors, windows, stairs, and fire extinguishers are. Determine in advance the nearest

More information

2012 SunTrust Center ERT Annual Review. 919 East Main St. Richmond, VA

2012 SunTrust Center ERT Annual Review. 919 East Main St. Richmond, VA 2012 SunTrust Center ERT Annual Review 919 East Main St. Richmond, VA 1 & 2 Purpose of Emergency Response Program Emergency Response Team, Members and Responsibilities Evacuation Procedures Other Emergency

More information

FIRE SAFETY PLAN. Ceramics/Sculpture Building 47 Service Rd 1 S Winnipeg, MANITOBA. May / Prepared by: Chris Pancoe

FIRE SAFETY PLAN. Ceramics/Sculpture Building 47 Service Rd 1 S Winnipeg, MANITOBA. May / Prepared by: Chris Pancoe FIRE SAFETY PLAN Ceramics/Sculpture Building 47 Service Rd 1 S Winnipeg, MANITOBA May / 2017 Prepared by: Chris Pancoe TABLE OF CONTENTS Contents A. BUILDING AUDIT:... 3 BUILDING DESCRIPTION... 3 1. Level

More information

Fire Evacuation Procedure Berkeley Green, John Huggett Engineering Hall

Fire Evacuation Procedure Berkeley Green, John Huggett Engineering Hall South Gloucestershire and Stroud College Fire Evacuation Procedure Berkeley Green, John Huggett Engineering Hall If you would like this document in an alternate format Please contact the Human Resources

More information

Health and Safety Draft Performance Standard HSPS 012. Provision of Personal Emergency Evacuation Plans (PEEPs) (Fire Safety)

Health and Safety Draft Performance Standard HSPS 012. Provision of Personal Emergency Evacuation Plans (PEEPs) (Fire Safety) Health and Safety Draft Performance Standard HSPS 012 Provision of Personal Emergency Evacuation Plans (PEEPs) (Fire Safety) 1 Safety, Health and Environment Unit Title Reference Number Provision of Personal

More information

Livingston Intl. Emergency Procedures Guide

Livingston Intl. Emergency Procedures Guide Livingston Intl. Emergency Procedures Guide Table of Contents Introduction... 2 EMERGENCY CONTACTS... 3 Emergency Procedures... 3 Employee Responsibilities... 3 Management Responsibilities... 3 Fire Warden/Searcher

More information

Fire Safety. A TUC guide for trade union activists

Fire Safety. A TUC guide for trade union activists Fire Safety A TUC guide for trade union activists Contents Section one Introduction 3 Section two The law 4 Section three Fire risk assesment 5 Section four Policies and procedures 6 Section five Enforcement

More information

Florida Building Code Chapter 9 Fire Protection Systems Advanced Course

Florida Building Code Chapter 9 Fire Protection Systems Advanced Course Florida Building Code 2010 Chapter 9 Fire Protection Systems Advanced Course 1 Introduction This course will cover specific sections of Chapter 9 that relate to fire alarm systems. While many contractors

More information

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION GUIDELINE RESIDENTIAL CARE FACILITIES 2007 CBC/CFC (R-3.1)

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION GUIDELINE RESIDENTIAL CARE FACILITIES 2007 CBC/CFC (R-3.1) July 1, 2010 SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION GUIDELINE RESIDENTIAL CARE FACILITIES Address: Permit #: Inspector: Date: Status: Inspector: Date: Status: This Checklist outlines

More information

Emergency Action Plan. Revised: 1/22/2018

Emergency Action Plan. Revised: 1/22/2018 Emergency Action Plan Revised: 1/22/2018 I. PURPOSE This plan is for the protection and safety of all members of the Branch College community, including students, faculty, staff, and campus visitors. During

More information

FIRE SAFETY UPGRADING CONSIDERATIONS for EXISTING SENIOR CITIZEN LODGES

FIRE SAFETY UPGRADING CONSIDERATIONS for EXISTING SENIOR CITIZEN LODGES FIRE SAFETY UPGRADING CONSIDERATIONS for EXISTING SENIOR CITIZEN LODGES 1. The major objective is to provide an acceptable degree of life safety from fire in existing senior citizen lodges. This document

More information

Use this guide to assist you when completing the Evacuation scheme application form.

Use this guide to assist you when completing the Evacuation scheme application form. Guide EVACUATION SCHEME APPLICATION ABOUT THIS GUIDE Use this guide to assist you when completing the Evacuation scheme application form. CONTENTS Before you start completing your application Section 1

More information

FIRE PLAN. In order to assure the safety of patients, visitors and staff, a standard response to fire or the potential of fire is required.

FIRE PLAN. In order to assure the safety of patients, visitors and staff, a standard response to fire or the potential of fire is required. FIRE PLAN PURPOSE In order to assure the safety of patients, visitors and staff, a standard response to fire or the potential of fire is required. This fire plan sets out the standard response for all

More information

To provide the requirements needed for Care Facilities Having 6 or Fewer Clients. This occupancy is classified as an R-3.1.

To provide the requirements needed for Care Facilities Having 6 or Fewer Clients. This occupancy is classified as an R-3.1. EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD STANDARD #F-003 EFFECTIVE 06-03-2009 PURPOSE To provide the requirements needed for Care Facilities Having 6 or Fewer Clients. This occupancy is classified

More information

Fire Drill Procedure and Guide

Fire Drill Procedure and Guide Fire Drill Procedure and Guide University of Tennessee Safety Procedure FS-002 Purpose, Applicability, and Scope Purpose The purpose of this document is to provide guidance for fire drills. Applicability

More information

[Name/title] is the Alternate Safety Officer/ Alternate Emergency Coordinator.

[Name/title] is the Alternate Safety Officer/ Alternate Emergency Coordinator. Community Health Center ================================================================= Subject: EMERGENCY EVACUATION PROCEDURE ================================================================= Policy

More information

Property Name & Address [ Property Name ] - [ Property Address ]

Property Name & Address [ Property Name ] - [ Property Address ] Emergency Procedure FIRE Property Name & Address [ Property Name ] - [ Property Address ] Purpose To ensure effective response and evacuation, by the property s Emergency Response Organization, to a fire

More information

Project: Location: Date Prepared: Last Reviewed:

Project: Location: Date Prepared: Last Reviewed: Project: Location: Date Prepared: Last Reviewed: Contents Premises Essential Information 4 Definitions & Acronyms 5 Introduction 5 Building Description and Safety Systems 7 General Strategy, Responsibilities

More information

WORKSHEET 3-1 THE MANITOBA OFFICE OCCUPANCY FIRE RISK INDEX FIRE SAFETY PARAMETER VALUES

WORKSHEET 3-1 THE MANITOBA OFFICE OCCUPANCY FIRE RISK INDEX FIRE SAFETY PARAMETER VALUES 1 WORKSHEET 3-1 THE MANITOBA OFFICE OCCUPANCY FIRE RISK INDEX FIRE SAFETY PARAMETER VALUES TABLE 3.1 CONSTRUCTION OF STRUCTURAL MEMBERS AND FLOOR AND ROOF (1) ASSEMBLIES (Applies each fire zone) Building

More information

M E M O R A N D U M. All Licensed Assisted Living Facilities. Felicia Cooper, Deputy State Fire Marshal Administrator Don Zeringue, Chief Architect

M E M O R A N D U M. All Licensed Assisted Living Facilities. Felicia Cooper, Deputy State Fire Marshal Administrator Don Zeringue, Chief Architect M E M O R A N D U M To: From: Approved: All Licensed Assisted Living Facilities Felicia Cooper, Deputy State Fire Marshal Administrator Don Zeringue, Chief Architect Henry Fry, Deputy Assistant Secretary

More information

Non-Emergency Direct Line Telephone Numbers. Emergency Direct Line Telephone Numbers

Non-Emergency Direct Line Telephone Numbers. Emergency Direct Line Telephone Numbers Introduction The Emergency Evacuation Plan (EEP) is the building s official response to fire and other life safety emergencies, and serves as an operational guide for the security and protection of building

More information

FIRE SAFETY PLAN ADMINISTERED BY: DEPARTMENT OF ENVIRONMENTAL HEALTH AND SAFETY

FIRE SAFETY PLAN ADMINISTERED BY: DEPARTMENT OF ENVIRONMENTAL HEALTH AND SAFETY FIRE SAFETY PLAN ADMINISTERED BY: DEPARTMENT OF ENVIRONMENTAL HEALTH AND SAFETY WRIGHT STATE UNIVERSITY FIRE SAFETY PLAN INTRODUCTION: Occupational Safety and Health (OSHA) standards for fire safety are

More information

Digiplex LED Keypads User s Manual

Digiplex LED Keypads User s Manual KLEDEU03.fm Page -1 Friday, May 4, 2001 11:25 AM Digiplex LED Keypads User s Manual KLEDEU03.fm Page 0 Friday, May 4, 2001 11:25 AM KLEDEU03.fm Page 1 Friday, May 4, 2001 11:25 AM TABLE OF CONTENTS 1.0

More information

Personal Protection Systems (PPS)

Personal Protection Systems (PPS) Personal Protection Systems (PPS) Guidance on the use, deployment and limitations of Personal Protection Watermist Systems in the homes of vulnerable people Prepared for: BRE Global Date: 12.11.2015 Report

More information

PROPOSED CHANGE TO THE 2007 FIRE CODE (OFC)

PROPOSED CHANGE TO THE 2007 FIRE CODE (OFC) PROPOSED TO THE 2007 FIRE CODE (OFC) PROPOSED OFC Record Division: A Reference Number: 1.4.1.2. DESCRIPTION OF PROPOSED EXISTING OFC PROVISIONS Delete the following definitions: Care or detention occupancy

More information

Emergency Preparedness

Emergency Preparedness 1 Emergency Preparedness Parents and society expect their children to be in a safe environment while in the care of child care programs. However, emergencies and disasters do occur in these settings and

More information

Fire Safety Plan Training 2017

Fire Safety Plan Training 2017 Fire Safety Plan Training 2017 1.1 Title Notes: A Fire Safety Plan provides participants with the knowledge necessary to prevent fires in the workplace and also focuses on the basic elements of fire prevention

More information

Fire Evacuation Procedure WISE Campus

Fire Evacuation Procedure WISE Campus South Gloucestershire and Stroud College Fire Evacuation Procedure WISE Campus If you would like this document in an alternate format Please contact the Human Resources Department Reviewed by: Job Title/Role:

More information

Preparedness Committee Security and Life Safety Commercial Office Building Protective Measures

Preparedness Committee Security and Life Safety Commercial Office Building Protective Measures Preparedness Committee Security and Life Safety Commercial Office Building Protective Measures Topic: Life Safety Provisions (Chicago) Date: Jan 2014; Revised May 2018 Background The City of Chicago has

More information

PERFORMANCE COMPLIANCE METHODS

PERFORMANCE COMPLIANCE METHODS CHAPTER 13 PERFORMANCE COMPLIANCE METHODS SECTION 1301 GENERAL 1301.1 Scope. The provisions of this chapter shall apply to the alteration, repair, addition and change of occupancy of existing structures,

More information

GROUP SR SPECIAL (ASSISTED SELF-PRESERVATION) OCCUPANCIES

GROUP SR SPECIAL (ASSISTED SELF-PRESERVATION) OCCUPANCIES APPENDIX SR GROUP SR SPECIAL (ASSISTED SELF-PRESERVATION) OCCUPANCIES The provisions contained in this appendix are adopted by the Building Codes Division of the State of Oregon. SECTION SR101 GENERAL

More information

Changes in NFPA

Changes in NFPA Changes in NFPA 72-2002 2002 Oregon Fire Code Committee November 25, 2003 Michael B. Baker, SET Automatic Fire Alarm Association MikeBaker@afaa.org 2003 Michael B. Baker 1 Table of Contents 1. Administration

More information

Nova Scotia Fire Dispatch Minimum Standards (2017)

Nova Scotia Fire Dispatch Minimum Standards (2017) Fire Service Association of Nova Scotia Nova Scotia Fire Dispatch Minimum Standards (2017) July 14, 2017 Scope This document sets out the minimum standards to which fire dispatch operations are expected

More information

Emergency Evacuation Plan South Patterson Building (SPB)

Emergency Evacuation Plan South Patterson Building (SPB) Emergency Evacuation Plan 1700 South Patterson Building (SPB) 2014 Table of Contents Section I: Purpose and Objectives Section II: General Guidelines Section III: Responsibilities of Emergency Coordinator

More information

(Fire) Emergency Evacuation Plan

(Fire) Emergency Evacuation Plan LAZARI INVESTMENTS LIMITED (Fire) Emergency Evacuation Plan Lazari Investments Maple House 149 Tottenham Court Road London W1T 7BN Version: September 2016 MKDS (Services) Ltd Fire Safety Services & Solutions

More information

APPROVED: Dayroom: Space for activities that is situated immediately adjacent to the youth sleeping areas and separated from them by a wall.

APPROVED: Dayroom: Space for activities that is situated immediately adjacent to the youth sleeping areas and separated from them by a wall. GEORGIA DEPARTMENT OF JUVENILE JUSTICE Applicability: { } All DJJ Staff { } Administration { } Community Services {x} Secure Facilities (RYDCs & YDCs) Transmittal # 17-4 Chapter 7: PHYSICAL PLANT Effective

More information

Rental Housing Inspection Guide

Rental Housing Inspection Guide BOONE FIRE DEPARTMENT Rental Housing Division 515-432-3446 www.boonegov.com/rental BUILDING DEPARTMENT Rental Housing Inspection Guide Boone Fire Department Welcome to the Rental Housing Inspection Guide

More information