SD3-60 AIRCRAFT MAINTENANCE MANUAL SYSTEM - DESCRIPTION & OPERATION (PRE MOD A8005)

Size: px
Start display at page:

Download "SD3-60 AIRCRAFT MAINTENANCE MANUAL SYSTEM - DESCRIPTION & OPERATION (PRE MOD A8005)"

Transcription

1 SD3-60 AIRCRAFT MAINTENANCE MANUAL z AMM STALL WARNING SYSTEM - DESCRIPTION & OPERATION (PRE MOD A8005) 1. Description A. General Physical and aural warning of an incipient stall condition is respectively provided by the simultaneous operation of control column ('stick') shakers and a warning horn; the latter of which is equipped with a red light which comes on during horn operation. The system is twinned, left and right, and is operationally triggered by either of two electrically anti-iced, vane-type detector units, located one in each wing's leading edge at station 308. Horn operation is shared and each half-system additionally provides operational back-up for the opposite stick shaker so that capability for full warning is retained should one of the detector units become inoperative in flight. B. Equipment (1) Detector Units: The detector unit is essentially comprised of an 'angle of attack' vane operated microswitch and each is equipped with three anti-icing elements rated at 109 watts max. The unit plate is profiled to the undersurface of the wing leading edge. The exposed operating vanes are lightly biased rearwards (contacts broken). The warning system is operationally inactive with the aircraft on the ground (except for testrefer to para 2.C.). The left and right units are respectively circuit-idented 1WH11 and 2WH11. (2) Stick Shakers: A stick shaker unit is mounted on each control column; each is basically comprised of an alloy casing housing an out-of-balance rotor which is operationally rotated by a 28V dc permanent magnet motor. The left and right units are respectively circuit-idented 1WH2 and 2WH2. (3) Warning horn and light: This unit, circuit-idented WH12, is shared by the left and right twin systems and is located on the right side of the flight compartment roof at frame station 54. The centrally disposed red light comes on during horn operation. Page 1

2 z SD3-60 AIRCRAFT MAINTENANCE MANUAL (4) Relays: 2. Operation (a) Control Relays. Two double-pole relays, idented CU and CN are located on each of the left and right equipment panel (1C and 2C). A CU relay, when energized via the related half-systems detector unit or by combined use of the associated test and heater switches, will conect the operating supplies to the associated stick shaker and the horn. CN relays are similarly energized by their opposite half-systems such that an alternative feed is available to each stick shaker. (b) Current-sensing Relays: A. Warning function Two single-pole current sensing relays, one left and one right are located in the flight compartment roof; the relays, respectively idented 1WH14 and 2WH14 are employed to illuminate the STALL section of associated indicator modules located above the PITOT/STATIC/STALL anti-icing switches on roof panel 4P when a control switch is ON selection has been effective (related detector unit heater element functional). When the angle-of-attack approaches the stall condition, airflow from the stagnation point will deflect a detector unit vane forward to complete the energizing supplies to the related halfsystem's CU relay and the CN relay in the opposite half-system. The CU relays so energized will connect the operating supplies to that half-system's stick shaker and to the shared warning horn and light. The CN relay will avail the opposite stick shaker of its operating supply should its CU relay remain de-energized as a result of failure of its detector unit contacts to changeover. Warning will persist until effective pilot-action to combat the threatened stall is taken. The warning function is ground tested in conjunction with the detector unit anti-icing as detailed in para C. Page 2

3 SD3-60 AIRCRAFT MAINTENANCE MANUAL z Stall Warning - Control & Equipment Figure 1 Page 3

4 z SD3-60 AIRCRAFT MAINTENANCE MANUAL B. Detector unit anti-icing Except when on the ground (wieght switch inhibited), selection of the two PITOT/STATIC/ STALL control switches (panel 4P) to On will connect the operating supplies to the associated detector unit element via the related current sensing relay. Satisfactory function is confirmed by the continuous illumination of the STALL section of an indicator module located above each switch. For ground testing refer para C. C. Testing Simultaneous ground testing of each half-systems warning function and detector's heaters is afforded by holding the appropriate of two STALL WARNING test switches (panel 11P) at TEST in conjunction with an ON selection for the related detector units anti-icing control switch. The test switch thus held, will electrically bypass the open contacts of the detector unit and weight switch. 3. Power Supplies System operating supplies are derived from the 28V dc left and right Essential Services Busbars via C/B No. 28 (5 amp), 29 (5 amp) on distribution panel 1D, and C/B No. 181 (5 amp), 182 (5 amp) on distribution panel 2D. Page 4

5 SD3-60 AIRCRAFT MAINTENANCE MANUAL z AMM STALL WARNING SYSTEM - MAINTENANCE PRACTICES 1. Adjustment/Test A. Preparation NOTE: Tests are performed with the aircraft self-supported which isolates the detector unit heaters through the weight switch. (1) Set all avionic and electrical switches to the off or neutral position. (2) Energize the main busbars from an external supply. Refer to , pb301. (3) Select the ELECTRICAL MASTER switch on panel 4P to EXTERNAL POWER. B. Function check the left system. (1) Close circuit breaker No.29 on distribution panel 1D. (2) Open circuit breakers No.28 on distribution panel 1D, and 181 and 182 on panel 2D. (3) Select ANTI-ICING PITOT/STATIC/STALL switch (left) on panel 4P to ON. (4) Press and hold STALL WARNING LEFT TEST switch on panel 11P and check that:- (a) the left detector unit begins to heat (b) the indicator module (left) on panel 4P is illuminated and the warning horn sounds and its integral light (red) is illuminated. (5) Subsequent to the operation and checks detailed in (4), close circuit breaker No.28 on panel 1D and check that the left stick shaker operates. Close circuit breaker No.181 on panel 2D and check that the right stick shaker operates. (6) Release the STALL WARNING LEFT TEST switch and check that:- (a) both stick shakers cease to operate (b) the warning horn ceases and its integral light is extinguished. the indicator module (left) is extinguished and (d) the detector unit begins to cool, signifying that the unit is switched off. (7) Check that when the left detector vane is moved fully forward under a load of not more than 10 grams, the horn, its integral light and both stick shakers operate. Page 201

6 z SD3-60 AIRCRAFT MAINTENANCE MANUAL C. Function test the right system. (1) Close circuit breaker No.182 on distribution panel 2D. (2) Open circuit breakers Nos.181 on panel 2D and 28 and 29 on panel id. (3) Select ANTI-ICING PITOT/STATIC/STALL switch (right) on panel 4P to ON. (4) Press and hold STALL WARNING RIGHT TEST switch on panel 11P and check that:- (a) the right detector unit begins to heat (b) the indicator module (right) on panel 4P is illuminated and the warning horn sounds and its integral light (red) is illuminated. (5) Subsequent to the operation and checks detailed in (4), close circuit breaker No.181 on panel 2D and check that the right stick shaker operates. Close circuit breaker No.28 on panel 1D and check that the left stick shaker operates. (6) Release the STALL WARNING RIGHT TEST switch and check that:- (a) both stick shakers cease to operate (b) the warning horn ceases and its integral light is extinguished. the indicator module (right) is extinguished and (d) the detector unit begins to cool, signifying that the unit is switched off. (7) Check that when the right detector is moved fully forward under a load of not more than 10 grams, the horn, its integral light and both stick shakers operate. (8) Disconnect the external power supply if no longer required. Page 202

Section - III SYSTEMS DESCRIPTION

Section - III SYSTEMS DESCRIPTION Section - III SYSTEMS DESCRIPTION Pro Line 21 Table of Contents Page GENERAL... 7-3 SYSTEM LOGIC... 7-3 CONTROLS and ANNUNCIATIONS... 7-3 OPERATION... 7-4 STALL WARNING SYSTEM... 7-4 STALL IDENTIFICATION

More information

WARNING AND TEST MASTER WARNING AND MASTER CAUTION SYSTEMS

WARNING AND TEST MASTER WARNING AND MASTER CAUTION SYSTEMS WARNING AND TEST MASTER WARNING AND MASTER CAUTION SYSTEMS The Warning and Caution systems are discussed here in conjunction with the Warning and Test Systems, primarily to cover the procedures for testing

More information

WARNING AND TEST MASTER WARNING AND MASTER CAUTION SYSTEMS

WARNING AND TEST MASTER WARNING AND MASTER CAUTION SYSTEMS MODEL 680 WARNING AND TEST MASTER WARNING AND MASTER CAUTION SYSTEMS The Warning and Caution systems are discussed here in conjunction with the Warning and Test Systems, primarily to cover the procedures

More information

Kelly Aerospace Willoughby, OH NC , Rev. A FAA APPROVED AIRPLANE FLIGHT MANUAL SUPPLEMENT FOR LC40-550FG AIRFRAME DE-ICING SYSTEM

Kelly Aerospace Willoughby, OH NC , Rev. A FAA APPROVED AIRPLANE FLIGHT MANUAL SUPPLEMENT FOR LC40-550FG AIRFRAME DE-ICING SYSTEM Aircraft SN: Aircraft Registration Number: This supplement must be attached to the FAA approved flight manual when the Kelly Aerospace airframe de-icing system is installed in accordance with STC SA02660CH.

More information

SECTION 6-15 FIRE PROTECTION

SECTION 6-15 FIRE PROTECTION SECTION 6-15 SYSTEMS DESCRIPTION Index Page General Description... 6-15-2 Engine Fire Protection... 6-15-2 Engine Fire Detection... 6-15-2 Engine Extinguishing... 6-15-3 Engine/Wheelwell and Pipe Zone

More information

OWNERS MANUAL MODEL 451 (-101 & -201)

OWNERS MANUAL MODEL 451 (-101 & -201) OWNERS MANUAL MODEL 451 (-101 & -201) Guardian Avionics CO Guardian, LLC. 1951 E Airport Drive Tucson, AZ 85756 Phone: 520-889-1177 8:00 am - 5:00 pm MST support@guardianavionics.com 2 Table of Contents

More information

Engine Fire Protection System

Engine Fire Protection System Engine Fire Protection System 1 1 LEFT FEED BUS LEFT CB PANEL CROSSOVER RIGHT FEED LEFT CB PANEL Fire Protection ARM UNLOCK DEPLOY S T EMER O W S NORM W BOTTLE 1 ARMED PUSH LH ENG FIRE PUSH RH ENG FIRE

More information

CHAPTER - 30 HIGHLIGHTS (Summary of Changes) Revision No. TR30-6 Dec 21/18 TO: HOLDERS OF THE AIRCRAFT MAINTENANCE MANUAL ( )

CHAPTER - 30 HIGHLIGHTS (Summary of Changes) Revision No. TR30-6 Dec 21/18 TO: HOLDERS OF THE AIRCRAFT MAINTENANCE MANUAL ( ) CHAPTER - 30 HIGHLIGHTS (Summary of Changes) Revision No. TR30-6 TO: HOLDERS OF THE AIRCRAFT MAINTENANCE MANUAL (06-117751) Pages that have been added or revised are summarized below. Remove and insert

More information

T-6B Electrical System. Created: 24 Aug 2015 Updated: 30 Aug 2015 T6BDriver.com

T-6B Electrical System. Created: 24 Aug 2015 Updated: 30 Aug 2015 T6BDriver.com T-6B Electrical System Created: 24 Aug 2015 Updated: 30 Aug 2015 T6BDriver.com Objectives Identify power sources of electrical system Understand electrical distribution within system Identify location

More information

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual ITC 2000 HEATING CONTROL CABINET Installation & Operation Manual VTI, Incorporated 24 McMillan Way Newark, DE 19713 Phone (302) 738 0500 FAX (302) 738 6594 Revision Level 0.03 Manual No. 90003314 June,

More information

SECTION 2-07 FIRE PROTECTION

SECTION 2-07 FIRE PROTECTION SECTION 2-07 TABLE OF CONTENTS Block General... 2-07-05..01 Engine and APU Fire Protection System... 2-07-10..01 Fire/Overheat Detection... 2-07-10..01 Fire Extinguishing... 2-07-10..04 Controls and Indicators...

More information

FOR SERVICE TECHNICIAN S USE ONLY

FOR SERVICE TECHNICIAN S USE ONLY F SERVICE TECHNICIAN S USE ONLY NOTE: This sheet contains important Technical Service Data. Tech Sheet Do Not Remove Or Destroy DANGER Electrical Shock Hazard Only authorized technicians should perform

More information

Section - III SYSTEMS DESCRIPTION

Section - III SYSTEMS DESCRIPTION Section - III SYSTEMS DESCRIPTION Pro Line 21 Table of Contents Page GENERAL...1-3 ANNUNCIATOR TYPES...1-3 ARRANGEMENT...1-3 REPEATER ANNUNCIATORS...1-3 Figure 1 - Master Warning Annunciations and Controls...1-4

More information

A D U ANNUNCIATOR DIM / TEST UNIT INSTALLATION MANUAL DESCRIPTION AND THEORY OF OPERATION

A D U ANNUNCIATOR DIM / TEST UNIT INSTALLATION MANUAL DESCRIPTION AND THEORY OF OPERATION AVIONICS ENGINEERING SERVICES A D U ANNUNCIATOR DIM / TEST UNIT INSTALLATION MANUAL DESCRIPTION AND THEORY OF OPERATION Document No. 92-0003-06 REV C May 31, 2000 INSTALLATION MANUAL DESCRIPTION AND THEORY

More information

Movement Detector GJD 300

Movement Detector GJD 300 Movement Detector GJD 300 Installation & Set Up Guide Introduction A CCTV event trigger utilising two independent passive infrared detectors combined in a T05 package. Both sensors have to trigger before

More information

DC3Training.com N28AA DC-3 Pilot s Handbook

DC3Training.com N28AA DC-3 Pilot s Handbook SECTION 7 FIRE PROTECTION Index General page 2 Operation page 4 Limitations page 4 Troubleshooting page 5 4/19/2012 crew@dc3training.com 1 GENERAL The fire protection system consists of an Edison fire

More information

SECTION AUTOMATIC TRANSFER SWITCHES

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 36 23 This section specifies the furnishing, complete installation, and connection of automatic transfer switches. 1.2 RELATED WORK A. Section 14 21 00, ELECTRIC

More information

Speed and Frequency Seite 1 von 7

Speed and Frequency Seite 1 von 7 Speed and Frequency Seite 1 von 7 E16 Systems for High Safety Speed ing, all with Triple Modular Redundancy. A choice of versions to meet various demands. Compliant with SIL3 / IEC 61508 and/or API 670.

More information

Intelligent Security & Fire Ltd

Intelligent Security & Fire Ltd OPERATIONAL NOTES FOR CONCEPT FIRE PANEL. NOTE ON NEW FIRE PANELS, POSITION 1 ON THE SIX WAY INTERNAL OPTION SWITCH IS TURNED ON, DISABLING THE ZONAL SOUNDERS. TO ENABLE ZONAL SOUNDERS TURN OFF. Operation

More information

AXICO ANTI-STALL CONTROLLABLE PITCH-IN-MOTION AND ADJUSTABLE PITCH-AT-REST VANEAXIAL FANS

AXICO ANTI-STALL CONTROLLABLE PITCH-IN-MOTION AND ADJUSTABLE PITCH-AT-REST VANEAXIAL FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS AXICO ANTI-STALL CONTROLLABLE PITCH-IN-MOTION AND ADJUSTABLE PITCH-AT-REST VANEAXIAL FANS FPAC FPMC FPDA CATALOG AX351 JULY 2001 WWW.TCF.COM

More information

DASSAULT AVIATION Proprietary Data

DASSAULT AVIATION Proprietary Data F900EX EASY 02-38-00 CODDE 1 PAGE 1 / 2 TABLE OF CONTENTS 02-38 02-38-00 TABLE OF CONTENTS 02-38-05 GENERAL Introduction Sources Equipment location 02-38-10 DESCRIPTION General 02-38-15 CONTROL AND INDICATION

More information

GUARDIAN : AUTOGUARD. User Manual

GUARDIAN : AUTOGUARD. User Manual 2018 : AUTOGUARD User Manual User Manual - Page 2 : AUTOGUARD Wireless PIR Intrusion Detection System User Manual 2 Contents User Manual - Page 3 Description Page No. 1. System Description 3 1.1 Scope

More information

DASSAULT AVIATION Proprietary Data

DASSAULT AVIATION Proprietary Data FALCON 7X 02-33-05 CODDE 1 PAGE 1 / 4 GENERAL ACRONYMS LIST BATT CB EPS LED LH MAU OP PPDB RH SSPC Battery Circuit Breaker Emergency Power Supply Light Emitting Diode Left Hand Modular Avionic Unit Overhead

More information

APU FIRE EXTINGUISHING SYSTEM - DESCRIPTION AND OPERATION

APU FIRE EXTINGUISHING SYSTEM - DESCRIPTION AND OPERATION 1.General APU FIRE EXTINGUISHING SYSTEM - DESCRIPTION AND OPERATION A.The APU fire extinguishing system has controls in two locations that release one application of fire extinguishing agent to a fire

More information

Bulletin 140G Molded Case Circuit Breakers Product Selection 225 A, I-Frame

Bulletin 140G Molded Case Circuit Breakers Product Selection 225 A, I-Frame Product Selection 225 A, I-Frame Assembled 225 A I-Frame Interrupting Rating/Breaking Capacity Thermal-Magnetic Circuit Breakers Interrupting Rating (50/60 Hz), UL 489/CSA C22.2-5, No. 5-02 [ka] Thermal-Magnetic,

More information

DASSAULT AVIATION Proprietary Data

DASSAULT AVIATION Proprietary Data F2000EX EASY 02-26-00 CODDE 1 PAGE 1 / 2 TABLE OF CONTENTS 02-26 02-26-00 TABLE OF CONTENTS 02-26-05 GENERAL Introduction Sources 02-26-10 DESCRIPTION Introduction Fire detection Fire extinguishing Portable

More information

AE October 1965 Reformatted October Hot Gas Bypass Control Systems

AE October 1965 Reformatted October Hot Gas Bypass Control Systems Hot Gas Bypass Control Systems AE21-1160 AE21-1160 October 1965 Reformatted October 2010 On many refrigeration and air conditioning systems, the refrigeration load will vary over a wide range. This may

More information

Fokker 50 - Integrated Alerting Unit

Fokker 50 - Integrated Alerting Unit GENERAL Failure conditions are processed by an Integrated Alerting Unit (IAU) for visual and aural presentation to the pilots. Pre-stall warning and ground proximity warning are not integrated. The IAU

More information

www. ElectricalPartManuals. com GADD MKIII Ground Fault Indication System Instruction Manual Ground Fault Protection

www. ElectricalPartManuals. com GADD MKIII Ground Fault Indication System Instruction Manual Ground Fault Protection Ground Fault Protection GADD MKIII Ground Fault Indication System Instruction Manual 7615 Kimbel Street, Mississauga, Ontario Canada L5S 1A8 Tel: (905)673-1553 Fax: (905)673-8472 Toll Free: 1-888-RESISTR

More information

Fokker 50 - Fire Protection

Fokker 50 - Fire Protection ENGINE General The engines are each equipped with a fire detection and a fire extinguishing system. The systems are controlled from the ENGINE FIRE panel, which is located at the overhead panel. Fire and

More information

FOR SERVICE TECHNICIAN S USE ONLY

FOR SERVICE TECHNICIAN S USE ONLY FOR SERVICE TECHNICIAN S USE ONLY NOTE: This sheet contains important Technical Service Data. Tech Sheet Do Not Remove Or Destroy DANGER Electrical Shock Hazard Only authorized technicians should perform

More information

360º FLUSH MOUNT CEILING PIR LIGHT CONTROLLER INSTALLATION & OPERATING. Cat No. SLFM360 INSTRUCTIONS

360º FLUSH MOUNT CEILING PIR LIGHT CONTROLLER INSTALLATION & OPERATING. Cat No. SLFM360 INSTRUCTIONS 360º FLUSH MOUNT CEILING PIR LIGHT CONTROLLER Cat No. SLFM360 INSTALLATION & OPERATING INSTRUCTIONS 1 Introduction The SLFM360 utilises passive infrared technology to detect heat radiation of moving human

More information

Box 122 Issue 4 Fort Erie, ON L2A 5M6 January 19, 2012 INSIGHT. Insight Instrument Corporation

Box 122 Issue 4 Fort Erie, ON L2A 5M6 January 19, 2012 INSIGHT. Insight Instrument Corporation INSIGHT Insight Instrument Corporation Box 122, Fort Erie, ON, L2A 5M6 Tel. 905-871-0733 Fax. 905-871-5460 Document Number 610C-ICA Issue 4 INSTRUCTIONS FOR CONTINUED AIRWORTHINESS For Insight Graphic

More information

360 Ceiling PIR Light Controller

360 Ceiling PIR Light Controller 360 Ceiling PIR Light Controller Model: SLFM360L Installation & Operating Instructions 1 1. General Information These instructions should be read carefully and retained for further reference and maintenance.

More information

PGR-8800 TECHNICAL FAQ

PGR-8800 TECHNICAL FAQ PGR-8800 SOLAR ARC-FLASH PRODUCTS RELAY CATALOG TECHNICAL FAQ What are the typical applications / system voltages? The PGR-8800 can be used on electrical systems operating at any voltage (AC or DC) since

More information

Canadair Regional Jet 100/200 - Water & Waste

Canadair Regional Jet 100/200 - Water & Waste INTRODUCTION The water and waste systems include potable water, lavatory waste equipment and system controls. Two potable water systems store and supply potable water to the galley and lavatory. The forward

More information

Contents. Preface. Chapter 2 Faults, types and effects The development of simple distribution systems Faults-types and their effects 7

Contents. Preface. Chapter 2 Faults, types and effects The development of simple distribution systems Faults-types and their effects 7 Practical Power System Protection for Engineers and Technicians Contents Preface ix Chapter 1 Need for protection 1 1.1 Need for protective apparatus 1 1.2 Basic requirements of protection 2 1.3 Basic

More information

DASSAULT AVIATION Proprietary Data

DASSAULT AVIATION Proprietary Data F2000EX EASY 02-38-00 CODDE 1 PAGE 1 / 2 TABLE OF CONTENTS 02-38 02-38-00 TABLE OF CONTENTS 02-38-05 GENERAL Introduction Sources Equipment location 02-38-10 DESCRIPTION General 02-38-15 CONTROL AND INDICATION

More information

TECHNICAL MANUAL UNIT, INTERMEDIATE DIRECT SUPPORT AND INTERMEDIATE GENERAL SUPPORT MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST)

TECHNICAL MANUAL UNIT, INTERMEDIATE DIRECT SUPPORT AND INTERMEDIATE GENERAL SUPPORT MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST) TM 55-1925-227-24&P TECHNICAL MANUAL UNIT, INTERMEDIATE DIRECT SUPPORT AND INTERMEDIATE GENERAL SUPPORT MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST) FIRE FIGHTING SYSTEM FOR LARGE

More information

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview Water Leak Detector - Four Zone with open/short-circuit detection Product overview The AX-WLDF is a four zone water leak detection module with open or short circuit sensor cable detection. The module must

More information

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc MASTER JOCKEY PUMP CONTROLLER Model JPCE INSTRUCTION MANUAL C 2018 Master Control Systems, Inc TABLE OF CONTENTS Important Safety Information. Page 3 General Description and Installation.. Page 4 Model

More information

CO Guardian LLC Document No E. AIRPORT DRIVE Date: TUCSON, AZ CO Guardian LLC 1951 E. Airport Dr.

CO Guardian LLC Document No E. AIRPORT DRIVE Date: TUCSON, AZ CO Guardian LLC 1951 E. Airport Dr. 1951 E. AIRPORT DRIVE Date: 8-20-2004 CO Guardian LLC 1951 E. Airport Dr. Tucson, AZ 85706 OWNERS MANUAL CARBON MONOXIDE DETECTOR MODEL 452-201 REMOTE UNIT MODEL 452-201 OWNERS MANUAL Page 1 of 22 INTENTIONALLY

More information

SETION EMERGENCY LIGHTING NATIONAL FIRE PROTECTION ASSOCIATION (NEPA) (2006) Life Safety Code, 2006 Edition

SETION EMERGENCY LIGHTING NATIONAL FIRE PROTECTION ASSOCIATION (NEPA) (2006) Life Safety Code, 2006 Edition SETION 16420 PART 1 - GENERAL 1.01 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation

More information

Installation Instructions

Installation Instructions Electric Heaters 5 --- 20 kw SMALL PACKAGED PRODUCTS (SPP) Accessory Electric Heaters For 13 SEER, R---410A, Z Chassis Installation Instructions NOTE: Read the entire instruction manual before starting

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower BULLETIN AX351 July 2001 AXICO ANTI-STALL Controllable Pitch-In-Motion and Adjustable Pitch-At-Rest Vaneaxial Fans Types FPAC, FPMC, FPDA A complete product bulletin including performance

More information

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW 12/23/16 Rev 9 UltraLITE Model ELU General Specification 4.2 KW to 5 KW UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW 1.0 General General Specification This specification describes

More information

MARC70 Installation Manual

MARC70 Installation Manual MARC70 Installation Manual SA 3/L/NVG SA 15 SA 24 SR 34 SR 54 SR 64 SR 263 SR 342 SR 623 SRU 1 SRU 5 SRU 10 3700 Osuna Rd. NE, Suite 711 Albuquerque, NM 87109 505.341.2930 www.sandia.aero 305147-00 This

More information

EMERGENCY PROCEDURES XL2

EMERGENCY PROCEDURES XL2 ENGINE FAILURE DURING FLIGHT GENERAL EMERGENCY PROCEDURES XL2 This section provides the recommended procedures for coping with various emergency or critical situations. All of the emergency procedures

More information

Hoffman Controls 759-ECM. Installation & Operating Instructions. Introduction. Installation. Pre-Installation Information/ Instruction

Hoffman Controls 759-ECM. Installation & Operating Instructions. Introduction. Installation. Pre-Installation Information/ Instruction Hoffman Controls Installation & Operating Instructions Introduction CAUTION Failure to read and understand the accompanying instructions and diagrams prior to energizing the Controller may result in permanent

More information

LAE10 LFE10. Use. Series 02

LAE10 LFE10. Use. Series 02 ISO 00 Flame Safeguards 7 7 LAE L Series 02 Supplementary data sheets 772 and 773 Flame safeguards for burners with intermittent operation. For safety reasons - self-test of flame supervision circuit,

More information

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver EBDSPIR-HB-DD Product Guide High bay PIR presence detector DALI / DSI dimming Overview The EBDSPIR-HB-DD PIR (passive infrared) presence detector provides automatic control of lighting loads with optional

More information

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES USER INSTRUCTIONS FOR THE CHEMGARD INFRARED GAS MONITOR SERIES To completely customize the specification to your exact application, modification to the

More information

Sundance Spas SPA EQUIPMENT SYSTEM. Installation Instructions. P/N Rev. A

Sundance Spas SPA EQUIPMENT SYSTEM. Installation Instructions. P/N Rev. A Sundance Spas SPA EQUIPMENT SYSTEM Installation Instructions P/N 6530-456 Rev. A Contents Important Notices 1 Important Safety Instructions 2 Where to Place the Equipment System 3 Connecting Pipes Between

More information

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc MASTER PRESSRE MAINTANENCE CONTROLLER Models PMCE INSTRUCTION MANUAL C 2018 Master Control Systems, Inc TABLE OF CONTENTS Important Safety Information. Page 3 General Description and Installation.. Page

More information

Guide Specification Model CTG Automatic Transfer Switch

Guide Specification Model CTG Automatic Transfer Switch Guide Specification Model CTG Automatic Transfer Switch PART 1 GENERAL 1.1 Scope A. It is the intent of this specification to secure a transfer switch that has been prototype tested, factory built, production

More information

CIRRUS AIRPLANE MAINTENANCE MANUAL

CIRRUS AIRPLANE MAINTENANCE MANUAL COOLING 1. DESCRIPTION On aircraft serials 183 and subsequent, an optional air condition system is available. This section contains the maintenance practices pertinent to this system. Cabin ventilation

More information

Installation Instructions

Installation Instructions Electric Heaters 5 --- 20 kw SMALL PACKAGED PRODUCTS (SPP) Accessory Electric Heaters For 13 SEER, R---410A Manufactured Home Installation Instructions NOTE: The Dual Point Kit can only be installed on

More information

100 FLUEBOOST

100 FLUEBOOST 100 FLUEBOOST f l u e b o o s t 1 0 0 The flueboost is a box shaped centrifugal fan unit with in line spigots for the flue connection, a pressure switch to ensure safe operation, all within a compact package.

More information

Installation Instructions

Installation Instructions 50ZPB, C, 50ZHB, C, PA3Z ---A, PH3Z ---A, PA4Z, PH4Z, PAJ4,PHJ4,WJA4,WJH4 SMALL PACKAGED PRODUCTS (SPP) Accessory Electric Heaters 5---20 kw For 14 SEER, R---410A Manufactured Home Installation Instructions

More information

VITMR-EBDSPIR-PRM. PIR Presence/Absence Detector IR with Ceiling Rose. Product Guide. Overview. Features

VITMR-EBDSPIR-PRM. PIR Presence/Absence Detector IR with Ceiling Rose. Product Guide. Overview. Features Product Guide VITMR-EBDSPIR-PRM PIR Presence/Absence Detector IR with Ceiling Rose Overview The VITMR-EBDSPIR-PRM PIR (passive infrared) presence detector provides automatic control of lighting loads.

More information

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs. MPAD-C-DALI-230V Product Guide Ceiling microwave presence detector DALI / DSI Overview The MPAD-C-DALI-230V microwave presence detector provides automatic control of lighting loads with optional manual

More information

INSTALLATION INSTRUCTIONS - PS1055LCP & PS1555LCP LED EMERGENCY DRIVER PS1055LCP & PS1555LCP

INSTALLATION INSTRUCTIONS - PS1055LCP & PS1555LCP LED EMERGENCY DRIVER PS1055LCP & PS1555LCP LED EMERGENCY DRIVER PS1055LCP & PS1555LCP INSTALLATION INSTRUCTIONS READ AND FOLLOW THESE INSTRUCTIONS BEFORE INSTALLATION TO ENSURE PROPER AND SAFE OPERATION SAVE THESE INSTRUCTIONS LED EMERGENCY DRIVER

More information

Northwest RV Supply Manual Compliments of Printed From 900 & 9100 Series

Northwest RV Supply Manual Compliments of Printed From 900 & 9100 Series 900 & 9100 Series Service Manual & Parts List for Models 9182 9183 9162 9163 982 983 962 963 Safety Information............... 1 Introduction................... 2 Specifications.................. 3 Operating

More information

FAA APPROVED AIRPLANE FLIGHT MANUAL SUPPLEMENT

FAA APPROVED AIRPLANE FLIGHT MANUAL SUPPLEMENT SUPPLEMENTAL TYPE CERTIFICATE NUMBER SA11103SC INSTALLATION OF SAFETY SYSTEMS FOR BEECHCRAFT B200GT AND B200CGT AIRPLANES IN THE KING AIR 250 CONFIGURATION (PRO LINE 21 AND PRO LINE FUSION AVIONICS) FAA

More information

Helicycle Crew Alerting System (CAS)

Helicycle Crew Alerting System (CAS) Helicycle Crew Alerting System (CAS) CAS Logic Boards Mounted on Radio Trays (Only 3 left as of Aug 14 th.) 8/14/2015 page 1 OF 12 INTRODUCTION If you view my Monterey Bay Shoreline video on YouTube, you

More information

CIRRUS AIRPLANE MAINTENANCE MANUAL

CIRRUS AIRPLANE MAINTENANCE MANUAL INDICATING/RECORDING SYSTEMS 1. DESCRIPTION This section describes the Indicating/Recording Systems which consists of an Annunciator Panel and related sensors and switches. A. Annunciator Panel - Serials

More information

7200 Series. Electromechanical Closer/Holder Releasing Devices

7200 Series. Electromechanical Closer/Holder Releasing Devices 7200 Series Electromechanical Closer/Holder Releasing Devices INTRODUCTION The 7200 Series Electromechanical Closer/Holders combine the functions of an electromechanical door holder with the 7700 series

More information

Application, Installation, Operation & Maintenance Manual

Application, Installation, Operation & Maintenance Manual APPROVED BY:JBJ PRESCIENT III FIRE ALARM & GAS EXTINGUISHING CONTROL PANEL Application, Installation, Operation & Maintenance Manual PAGE 1 of 43 CONTENTS 1. INTRODUCTION... 3 2. GENERAL DESCRIPTION...

More information

VIKING RANGE CORPORATION, P.O. DRAWER 956, GREENWOOD,MS USA

VIKING RANGE CORPORATION, P.O. DRAWER 956, GREENWOOD,MS USA VIKING RANGE CORPORATION, P.O. DRAWER 956, GREENWOOD,MS 38930 USA TABLE OF CONTENTS VDSC ( Dual fuel ) / VESC (Electric) RANGES / VERT (Rangetop) COMPONENTS AND FUNCTIONAL PARTS: Control / Timer ------------------------------------------------------------------------------------------------------

More information

Product Guide. Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Product Guide. Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. Product Guide LPCMPIRDSI Ceiling PIR presence detector DALI / DSI dimming Overview The LPCMPIRDSI PIR (passive infrared) presence detector provides automatic control of lighting loads with optional manual

More information

CIRRUS AIRPLANE MAINTENANCE MANUAL

CIRRUS AIRPLANE MAINTENANCE MANUAL MODEL SR INDICATING/RECORDING SYSTEMS 1. DESCRIPTION This section describes the Indicating/Recording Systems which consists of an Annunciator Panel and related sensors and switches. The annunciator assembly

More information

Gasflag. Single Channel Control Panel Alarm Only Apparatus. Installation, operating and maintenance instructions, M07225.

Gasflag. Single Channel Control Panel Alarm Only Apparatus. Installation, operating and maintenance instructions, M07225. Gasflag Single Channel Control Panel Alarm Only Apparatus Installation, operating and maintenance instructions, M07225 Issue 2 1/07/05 Crowcon Detection Instruments Ltd 2 Blacklands Way Abingdon Business

More information

Event Detection System (EDS)

Event Detection System (EDS) WaveGrid Event Detection System (EDS) Installation, Operations and Maintenance Guide Control Module Revision 6.0 June 24 th, 2016 Sensor Module I Functional Description The Event Detection System (EDS)

More information

DYCU-3 AEROSOL FIRE EXTINGUISHER CONTROL UNIT OPERATION MANUAL

DYCU-3 AEROSOL FIRE EXTINGUISHER CONTROL UNIT OPERATION MANUAL DYCU-3 AEROSOL FIRE EXTINGUISHER CONTROL UNIT OPERATION MANUAL DOC: GLT.MAN-136 1 INDEX INTRODUCTION 3 CONNECTIONS 4 OPERATION 5 LINKING 6 TECHNICAL INFO 7 DOC: GLT.MAN-136 2 INTRODUCTION The Dynameco

More information

Dornier 328Jet - Lights

Dornier 328Jet - Lights LIGHT and ENGINE START Control Panel (Sheet 1 of 5) Page 1 Light and ENGINE START Control Panel (Sheet 2 of 5) Page 2 LIGHT and ENGINE START Control Panel (Sheet 3 of 5) Page 3 LIGHT and ENGINE START Control

More information

For assistance with the product please contact: HELPLINE. For a product brochure please contact:

For assistance with the product please contact: HELPLINE. For a product brochure please contact: For assistance with the product please contact: HELPLINE 020 8450 0515 or email helpline@timeguard.com For a product brochure please contact: Timeguard Limited. Victory Park, 400 Edgware Road, London NW2

More information

Conventional Smoke Detectors KFAPO

Conventional Smoke Detectors KFAPO Kingfisher Company, inc. Conventional Smoke Detectors KFAPO Features: Wide operating voltage, 9-33 VDC Advanced electronic technology Flashing LED Magnetic test switch Proven detection performance Designed

More information

ELECTROPROJECT GTV-A POWER SUPPLY FOR DOOR MAGNETS

ELECTROPROJECT GTV-A POWER SUPPLY FOR DOOR MAGNETS ELECTROPROJECT POWER SUPPLY FOR DOOR MAGNETS Innovative and carefully thought out Always the right drive ELECTROPROJECT AANDRIJFTECHNIEK ElectroProject has evolved over the last 75 years from a technical

More information

PART 4 ELECTRICAL STANDARDS

PART 4 ELECTRICAL STANDARDS PART 4 ELECTRICAL STANDARDS 1.0 INTRODUCTION AND SCOPE: These standards reflect the general requirements and recommendations of elevator contractors, with respect to the power distribution system to achieve

More information

Installation Instructions

Installation Instructions 30GTN015-035 Reciprocating Liquid Chillers with ComfortLink Controls 50/60 Hz Installation Instructions CONTENTS Page SAFETY CONSIDERATIONS...................... 1 INSTALLATION.................................1-11

More information

The CAB & DAB Air Curtains

The CAB & DAB Air Curtains The CAB & DAB Air Curtains Frequently Asked Questions General Positioning Page 2 Electrical & Connection Page 4 Electric Heated Page 5 Electronic door triggered shutdown feature (Electric) Page 5 Electronic

More information

Safety Instructions MS 10B ALARM UNIT MS 10B ALARM UNIT. Used symbols. Always observe this information to prevent damage to the device

Safety Instructions MS 10B ALARM UNIT MS 10B ALARM UNIT. Used symbols. Always observe this information to prevent damage to the device Safety Instructions Used symbols Important Comments Before starting with installation of the MS 10B Alarm Unit, we recommend you to read the important information beneath. Qualification The installation

More information

Bombardier Challenger Fire Protection

Bombardier Challenger Fire Protection GENERAL The fire protection system is divided into two separate subsystems: Fire and overheat detection system; and Fire extinguishing system. The fire and overheat detection system includes components

More information

CAUTION. All safety information must be followed as provided in Service Manual RS ! WARNING

CAUTION. All safety information must be followed as provided in Service Manual RS ! WARNING Amana Technical Information³Refrigerator P1303511W Due to a possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this refrigerator. Refer

More information

FOR SERVICE TECHNICIAN S USE ONLY

FOR SERVICE TECHNICIAN S USE ONLY F SERVICE TECHICIA S USE OY TE: This sheet contains important Technical Service Data. Tech Sheet Do ot Remove Or Destroy DAGER Electrical Shock Hazard Only authorized technicians should perform diagnostic

More information

Wiring Instructions for the 2900 Series FIREGUARD Combination Door Closer-Holder and Releasing Device with Integral Smoke Detector

Wiring Instructions for the 2900 Series FIREGUARD Combination Door Closer-Holder and Releasing Device with Integral Smoke Detector Wiring Instructions for the 900 Series FIREGUARD Combination Door Closer-Holder and Releasing Device with Integral Smoke Detector CAUTION: FAILURE TO INSTALL OR ADJUST PROPERLY MAY RESULT IN INJURY OR

More information

JBL2088HES JBL2088HES0, JBR2088HES JBR2088HES0, JFC2089HEP JFC2089HEP0, JFC2089HES JFC2089HES0, JFC2089HPF JFC2089HPF0, JFC2089HPY JFC2089HPY0

JBL2088HES JBL2088HES0, JBR2088HES JBR2088HES0, JFC2089HEP JFC2089HEP0, JFC2089HES JFC2089HES0, JFC2089HPF JFC2089HPF0, JFC2089HPY JFC2089HPY0 Bottom Mount Refrigerator Technical Information JBL2088HES JBL2088HES0, JBR2088HES JBR2088HES0, JFC2089HEP JFC2089HEP0, JFC2089HES JFC2089HES0, JFC2089HPF JFC2089HPF0, JFC2089HPY JFC2089HPY0 Due to a possibility

More information

ARS2304A PARS2304AB0 ARS2604A PARS2604AB0 ARS2304A PARS2304AC0 ARS2604A PARS2604AC0 ARS2304A PARS2304AW0 ARS2604A PARS2604AW0 !

ARS2304A PARS2304AB0 ARS2604A PARS2604AB0 ARS2304A PARS2304AC0 ARS2604A PARS2604AC0 ARS2304A PARS2304AW0 ARS2604A PARS2604AW0 ! Amana Technical Information³Refrigerator ARS2304A PARS2304AB0 ARS2604A PARS2604AB0 ARS2304A PARS2304AC0 ARS2604A PARS2604AC0 ARS2304A PARS2304AW0 ARS2604A PARS2604AW0 Due to a possibility of personal injury

More information

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev AL802ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 031703 Overview: The Altronix AL802ULADA is an extremely cost effective 8 amp voltage regulated

More information

Table-1: Clarifications and modification in tender specifications based on Pre-bid meeting discussion

Table-1: Clarifications and modification in tender specifications based on Pre-bid meeting discussion Table-1: Clarifications and modification in tender s based on Pre-bid meeting discussion Sr. Ref Page. 1 4 Clause Site Preparation and Partitions walls 2 11 SLD 3 18 Batteries 4 18 Batteries 5 32 to 34

More information

Flame Safeguards LFE10. Building Technologies HVAC Products

Flame Safeguards LFE10. Building Technologies HVAC Products 7 71 Flame Safeguards LAE LFE Flame safeguards for burners with intermittent operation The LAE is used for the supervision and indication of oil flames The LFE is used for the supervision and indication

More information

INSTALLATION GUIDE

INSTALLATION GUIDE INSTALLATION GUIDE 22 WWW.POWERBOXINC.COM Every grower s worst nightmare has to be an electrical fire. The sad part is, grow room fires happen far more often than they should, usually caused by overloaded

More information

Owner s Guide and Installation Manual

Owner s Guide and Installation Manual For Your Records and Warranty Assistance For reference, also attach your receipt or a copy of your receipt to the manual. Model Name Type 2 Models Owner s Guide and Installation Manual Model No. Catalog

More information

THERMOMAX COLTREC RCX 100 MICROPROCESSOR REFRIGERATION CONTROL SYSTEM ENGLISH.

THERMOMAX COLTREC RCX 100 MICROPROCESSOR REFRIGERATION CONTROL SYSTEM ENGLISH. THERMOMAX COLTREC RCX 100 MICROPROCESSOR REFRIGERATION CONTROL SYSTEM ENGLISH www.thermomax-group.com CONTENTS SECTION 1 - INTRODUCTION... 2 SECTION 2 - INSTALLATION... 3 2.1 - RCX 100 UNIT... 4 2.2 -

More information

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor.

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor. Product Guide EBDSM-DD Ceiling PIR presence detector DALI / DSI dimming Overview The EBDSM-DD PIR (passive infrared) presence detector provides automatic control of lighting loads with optional manual

More information

Liberty XL2 Emergency Procedures Checklist

Liberty XL2 Emergency Procedures Checklist EMERGENCY PROCEDURES XL2 GENERAL This section provides the recommended procedures for coping with various emergency or critical situations. All of the emergency procedures required by the FAA, as well

More information

A. American National Standards Institute (ANSI): Establishes requirements applicable to certifying direct gas-fired heaters.

A. American National Standards Institute (ANSI): Establishes requirements applicable to certifying direct gas-fired heaters. SECTION 15622 DIRECT GAS-FIRED BURNER & MANIFOLD SYSTEM PART 1: GENERAL 1.1 Section includes: A. Direct gas-fired heater modules B. Controls C. Equipment schedule 1.2 Related Sections A. Section 01655:

More information

T0158_ATRcouvDEF_SYSTEM42notPEC.indd COUV1 19/05/10 16:29

T0158_ATRcouvDEF_SYSTEM42notPEC.indd COUV1 19/05/10 16:29 42-300 Introduction This Systems guide is an essential tool for all ATR flight crew and engineer to learn or review ATR systems operation. To make learning process easier, systems are introduced in a user-friendly

More information

Who says you have to sacrifice the fun of grilling

Who says you have to sacrifice the fun of grilling Low-profile, one-piece grilling grate Two 1400-watt heating elements Model IG15/S Illuminated electronic touch controls Removable collection pan Graduated control lighting Location of rating plate The

More information

FAA APPROVED ROTORCRAFT FLIGHT MANUAL SUPPLEMENT FOR THE HONEYWELL MK XXII ENHANCED GROUND PROXIMITY WARNING SYSTEM (EGPWS) [Aircraft Type]

FAA APPROVED ROTORCRAFT FLIGHT MANUAL SUPPLEMENT FOR THE HONEYWELL MK XXII ENHANCED GROUND PROXIMITY WARNING SYSTEM (EGPWS) [Aircraft Type] FAA APPROVED ROTORCRAFT FLIGHT MANUAL SUPPLEMENT FOR THE HONEYWELL MK XXII ENHANCED GROUND PROXIMITY WARNING SYSTEM (EGPWS) [Aircraft Type] Serial No. This Supplement must be attached to the FAA Approved

More information