Fire ISSUE. In This. Product Announcements New Viking Sprinklers for Institutional Security SupplyNet. Call Viking TOLL-FREE.
|
|
- Lewis Harrell
- 6 years ago
- Views:
Transcription
1 On March 1999 Fire SupplyNet Product Announcements New Sprinklers for Institutional Security 210 N. Industrial Park Road Hastings, MI Phone: Facsimile: Web: supplynet.com To meet the need for tamper-resistant fire extinguishing equipment in institutional settings, has introduced Institutional Quick Response Flush Pendent and Sidewall Sprinklers. Model HQR-2 pendent and horizontal sidewall sprinklers are designed specifically for use with concealed piping in institutional mental health occupancies, correctional facilities, or anywhere occupants may be likely to tamper with fire sprinklers. These small, flush, solder-link and lever spray sprinklers provide low breakaway features during conditions of misuse. An optional retaining flange offers a lock-tight design that secures piping to prevent sprinkler movement away from ceilings or walls. They can be disassembled in two ways: one destroys only the escutcheon and lockring, and the other destroys the entire unit. And, for installation flexibility, the horizontal sidewall sprinklers can be installed from 4 to 12 below the ceiling. Model HQR-2 sprinklers have a 1/2 thread and a 1/2 orifice. They consist of a sprinkler body with polished chrome finish, a lockring, and a 3-1/4 (82,5 mm) diameter thread-on escutcheon plate with chrome finish. They provide standard coverage per NFPA-13 (225 sq. ft.), are UL and C- UL listed as Quick Response Flush Sprinklers, and are approved for a temperature of 165 F/74 C. Non- UL/C-UL listed versions are available in 220 F/104 C. For more information, contact your SupplyNet distributor. Call TOLL-FREE You can call s Technical Service Department toll-free from anywhere in the continental U.S In This ISSUE Product Announcements... pg 2 Ask The Tech Rep... pg 3 Price Changes... pg 5 Personnel-y Speaking... pg 5
2 Product Announcements NEW! Large Orifice and Extended Coverage Concealed Sprinklers Now offers you important new options for nearly undetectable fire protection. The breakthrough technology of Horizon Mirage concealed sprinklers has allowed to create new extended coverage (EC) and large orifice (LO) models that meet strict testing criteria for such usages. s new Model B- 2 Extended Coverage Sprinkler is available with a 3/4 NPT thread, which will be UL and C-UL listed as a 1) Quick Response Extended Coverage Concealed Sprinkler and 2) Standard Response Extended Coverage Concealed Sprinkler for light hazard occupants. A second sprinkler, also Model B-2, is available and is UL and C-UL listed as a Large Orifice Concealed Sprinkler. LOs are ideal for light and ordinary hazard applications. Both new models utilize the current Model B-2 cover plate and feature Mirage adjustability, which makes them relatively economical to install. Premiers Low-Cost Sprinklers in Black now offers an alternative to their standard black, extra large orifice (ELO) pendent sprinklers. Available in black teflon for several years, these sprinklers are now available in a lowercost black polyester paint, and are ideal for use in movie theaters or other areas where ceilings need to be dark. The black Model M Extended Coverage Light Hazard (ECLH) and Ordinary Hazard (ECOH) pendent sprinklers are thermosensitive, glass-bulb spray pendents with a corrosion-resistant polyester coating. They have a special deflector to meet either light or ordinary hazard density requirements for specific extended coverage areas, and their extra-large orifices produce the flows required at lower pressures than standard and large orifice sprinklers require. Both the ECLH and ECOH versions have a 3/4 NPT (20 mm) thread, and nominal 5/8 (16 mm) orifice. They are UL and ULC listed as Standard Response Sprinklers, and are New York City approved. To learn more, talk to your SupplyNet distributor. New RetroFit Cup Occasionally, when changing out recessed sprinklers, the recessed escutcheon cup will be too deep. To solve this problem, has released a new Retrofit Cup with a depth of 1-1/16. It comes in bright brass, Navajo white, and black, as well as in the standard polished chrome and white finishes. You can find additional information on this escutcheon on the enclosed price page 10, dated February, Wheatland Releases New Sprinkler Pipe SupplyNet is now stocking Wheatland Tube s new Mega line of sprinkler pipe, in addition to their existing line of Schedule 10 and 40 pipe. Please contact your local SupplyNet branch for more information and catalogs. Re-Introducing Old Shields and Guards In the November 1998 issue of On-Fire, introduced new water shields and guards that passed the more stringent UL testing requirements. Now we would like to re-introduce our old water shields and guards. Though lacking the UL listing, these products maintain their FM and New York City approval, and are a lower-cost alternative to the new shields and guards. Please refer to the enclosed price page 16, dated February 1999, for more information. Model A-1 Sprinkler Guard Model B-1 Upright Water Shield and Guard Assembly Model C-1 Pendant Water Shield and Guard 2
3 ?? Ask the Tech Rep... Q. doesn t include a relief valve with its dry valve trim. Why?? A. When there is a potential to overpressurize the system, the relief valve protects the system and keeps this from happening. However, relief valves are only needed when using the older manual fill systems, which require an on-site person to regularly check the system and then manually refill it from plant air if necessary. Automatic air supplies, such as plant air or local supply air, require an air maintenance device which prevents the system from accepting additional air once maximum air pressure has been reached. Because of this safety feature, no relief valve is required. Q. Can the supervisory signal at the release control panel be a latching signal, or does it need to be self-resetting? A. There has been a change to NFPA 72 which states that supervisory signals are allowed to be a latching signal. This means that the panel can only be reset after someone has checked to ensure the problem that caused the latching supervisory signal to activate has been solved. This change has been accepted as a clarification to NFPA 72 and will be included in the 1999 edition of the manual. Notifier is currently working on developing a feature on all of their panels that will track the supervisory signal and not latch. Low end panels, including the RP 1001, PAR-3, and Firecycle III panels currently have latching supervisory circuits. Higher end programmable panels can be constructed to have either latching or tracking circuits. It is worth noting that the Firecycle III panel gives a ground fault indication if one of the two wires inside the aluminum sheath breaks. This will short out to the aluminum cable or another ground, but will not trip the detection system. Fireflex Recommends Detectors for use with TotalPac Systems in MRI Rooms. MRI (Magnetic Resonance Imaging) devices are being installed in ever increasing numbers of hospitals and health centers. The unique features of the TotalPac systems make them a very popular solution for the protection of MRI installations. However, the MRI machine itself creates an unusual set of issues for the contractor that must choose fire detectors to install. When in use, an MRI unit produces a large magnetic field which acts very much like an electromagnet pulling any metal object within its reach. For this reason, precautions must be taken to avoid any metallic components within the same room as the MRI unit. In addition, some smoke detectors will go off whenever the machine is activated, causing very annoying and unnecessary false alarms. Fireflex Systems, the manufacturer of the TotalPac Integrated Fire Protection System, presented this issue to the engineering department of System Sensor, who makes the brand of smoke detector recommended for use with the TotalPac system. System Sensor suggested using their 2 or 4 wire direct fire detectors, models 1400 and 2400, in MRI rooms. However, models 1451 and 2451, which are normally used with the TotalPac system, should not be used in this application, as they contain a Reed Switch test magnet that will cause them to activate every time the MRI unit is fired. This same problem will occur with all Duct Detectors, as well as with the Intelligent Line of addressable detectors. The TotalPac Integrated Fire Protection System has long been the system of choice for fire detection in MRI rooms. Providing contractors with recommendations on the proper equipment to use in combination with the TotalPac system will ensure that the fire detection problems that can be caused by electromagnetic fields don t occur. For further information, please contact your local SupplyNet office. 3
4 Another First! New Totally Integrated Foam/Water Systems. Say good-bye to guesswork about the compatibility of foam/water system components. has introduced the first truly integrated foam/water systems, ensuring the compatibility and high quality of every component from foam concentrate to control system. s Low Flow foam system produces an effective foam/water solution at very low water-flows past the foam proportioning device. This system was recently tested in fires involving flammable liquid stored in relieving style drums. Alarm Valve Pilot Operated Pressure Regulating Valve ILBP System Drum storage of flammable liquid groups 1B, 1C, II and IIIA has long been limited to two drums high with water protection at a.60 density over 3,000 sq. ft., or foam system protection at.30 density over 3,000 sq. ft. But extensive testing proves that s Low Flow foam system enhances a standard sprinkler system so that at the same density (.60 gpm) storage height can safely be doubled to four high. And, even with existing piping at.45 density, the Low Flow foam system allows you to stack drums three high. Bladder Tank AR-AFFF and AFFF foams are fast-acting synthetics designed for use in systems to provide the best possible fire control over most types of flammable liquid hazards. AFFF is available in 1% and 3% concentrates, and AR-AFFF is available in two 3% x 3% types. s integrated foam/water systems include the Low Flow Wet Riser, the only bladder system FM approved for closed head operation with an in-line balanced proportioning (ILBP) method. The system is completely hydraulic and combines the dependability of a bladder system Concentrate Control Valve with the advantages of a conventional foam pump/ilbp system without the added cost of wiring and maintaining a foam pump. s other integrated systems are the Low Flow Preaction, Deluge, Wet, and Dry Risers. offers three methods of proportioning and all components required to complete the system: bladder tanks, concentrate controllers, ILBPs, foam pump skids, fixed eductors, concentrate control valves, and pressure regulating valves to meet your requirements for hazard types and available water pressure. Discharge devices include sprinklers, nozzles, foam chambers, foam makers, and monitor nozzles. Want more information? Order the new Foam Data Book from your local distributor today. Additions to SupplyNet Data Book New Tolco Catalog Insert The enclosed Tolco packet replaces the Tolco information you currently have in your SupplyNet Data Book. It includes all of the latest products from Tolco, including the Figure 22-C CPVC Hanger, the Figure 58 Side Beam Attachment, the Figure 200 Ring Hanger, and the Figure 800 Sway Brace Attachment. All items are already available from SupplyNet inventory. New Harvel Data Page In response to requests from the sales force, Harvel has put together the enclosed specification sheet for the CPVC Blazemaster sprinkler pipe, which is manufactured in both their Easton, Pennsylvania factory, and their new Bakersfield, California facility. Add this page to the pipe/fitting section of your SupplyNet Data Book. 4
5 Price Changes Kennedy Cost Increase Due to an increase in our costs from Kennedy on gate and check valves, there will be an upward price adjustment of 5 to 7% on resilient wedge gate valves, check valves and post indicators, effective April 1, This price change was received too late and is not reflected in the enclosed net pricing report. Please consult your local SupplyNet representative for new net pricing on these items. Price Increase at Anti- Seize Technology For the first time in many years, Anti- Seize Technology has increased their prices for their TFE pipe thread sealant. The increase is about 6%, and will be effective for SupplyNet customers on March 15, Ward Increases Costs Ward has recently increased their costs for cast iron threaded and flanged fittings, which will cause a 6% price increase, effective April 1, The enclosed net pricing report does not reflect this increase. New net pricing information can be obtained from your local SupplyNet representative. Nibco Price Increase Nibco has just announced a price increase effective April 1, The cost of all bronze gate, globe and check valves will rise by 5%. The T ball valves will also increase 5%, however, the T-580 will not increase. Please contact your local SupplyNet representative for new net pricing on these items, as the price change was received too late to be reflected in the enclosed net pricing report. personnel-y Speaking Maddox Becomes President The Corporation has appointed Bill Maddox as its new president. Maddox, a Michigan State University graduate, brings his 30 years experience in the automotive, chemical, computer software, and office furniture industries to his new position at, where his primary focus will be ensuring the company s continued growth into the 21st century. We are pleased to have someone with such a diverse background as our new president, said Thomas T. Groos, CEO of s parent company, E. Tyden Inc. Bill s expertise provides us with the catalyst to strengthen and improve our company as we continue to grow. Please welcome Bill to. We Apologize... Obitz New Territory Manager Jeff Obitz has joined SupplyNet as the new territory manager for Texas and Louisiana. A 13-year veteran of the fire sprinkler industry, Jeff s sales territory will include the areas in and around Dallas-Ft. Worth, Waco, San Antonio, and Austin, Texas, and in Shreveport, Louisiana. Jeff has many years of experience working in the purchasing department and as shop foreman at Emergency Fire Protection in Keller, Texas. He has also worked in the plumbing supply industry. Please give Jeff a warm SupplyNet welcome. Firecycle III The Firecycle III trim data on pages 441a through 449a in your SupplyNet Data Book is incorrect. It indicates that the flow control and check valves should be ordered separately from the trim. The trim and valves are actually sold together as the Firecycle III Valve Package. Model M Quick Response Extended Coverage Dry Sidewall Sprinkler In Table 1 on page 109a of your Data Book, the square that indicates Maximum Area of Coverage 4, Length x Width is incorrect. The square should read Maximum Area of Coverage 4, Width x Length. Model M Standard Response Extended Coverage Dry Sidewall Sprinkler In your Data Book, an error has been made in Table 1 on page 109e. The square indicating Maximum Area of Coverage 4, Length x Width should be changed to Maximum Area of Coverage 4, Width x Length. Visit s website to view new products and features and to download and print new data pages. 5
E x t E N d e d Co v e r ag e S p r i n k l e r s. Office Buildings Hotels Hospitals Libraries. High-Piled Storage Big-Box Retailing
Extended Coverage Sprinklers Extended Coverage Sprinklers are intended for the protection of areas larger than those specified in standard installation rules and for specific light, ordinary, or extra
More informationS p e c i a l P u r p o s e S p r i n k l e r s. Attic Spaces Retail Windows High Security Institutions Minimal Water Damage Conditions
SPecial Purpose Sprinklers The Tyco ILLUSION 11.2 K-factor sprinkler is designed specifically for Las Vegas' standards. A fast response, extra large orifice concealed pendant sprinkler, the ILLUSION is
More informationModel F1 Residential Sprinklers for Design Density of.10 gpm/ft 2
Model F1 Res s engineered for the lowest flows to meet the minimum design density of.05 gpm/ft 2 Types: 1. F1 Res 49 Pendent 2. F1 Res 49 Recessed Pendent/F1 3. F1 Res 49 Recessed Pendent/FP 4. F1 Res
More informationModel MBEC-14. Extended Coverage Ordinary & Extra Hazard Horizontal Sidewall Sprinklers for Metal Building Applications. Model MBEC-14 (SIN R6932)
Model MBEC-14 (SIN R6932) Features 1. Designed to be installed on piping that is supported by the primary structure, not the purlins. 2. Provides Extended Coverage Ordinary & Extra Hazard protection to
More informationec/qrec ordinary hazard upright and pendent sprinklers vk570 and vk572 (k14.0)
Sprinkler 83h 1. DESCRIPTION Viking Standard/Quick Response Extended Coverage Ordinary Hazard (ECOH) Upright Sprinkler VK570 and Pendent Sprinkler VK572 are thermosensitive glass bulb spray sprinklers
More informationINSTITUTIONAL QUICK RESPONSE/QREC FLUSH PENDENT SPRINKLER VK410 (K5.6) TECHNICAL DATA
Page 1 of 8 1. PRODUCT DESCRIPTION Viking Institutional Style Quick Response Standard Coverage/Extended Coverage Flush Pendent Sprinklers are small, flush, solder link and lever sprinklers made with tamper-resistant
More informationINSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA
Sprinkler 126k Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. PRODUCT DESCRIPTION Viking Institutional Style Quick Response Flush Horizontal
More informationINSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA
August 14, 2013 Sprinkler 126k 1. PRODUCT DESCRIPTION Viking Institutional Style Quick Response Flush Horizontal Sidewall Sprinklers are small, flush, solder link and lever sprinklers made with tamper-resistant
More informationModel F1 LO K 8.0 (115 metric) Standard Response Sprinklers
Model F1 LO K 8.0 (115 metric) Standard Response s Bulletin 117 Rev. Z Bulletin 117 Rev. Z Model F1 LO Standard Spray Upright Standard Spray Pendent Extended Coverage Pendent Conventional Model F1 LO Recessed
More informationEC/QREC ORDINARY HAZARD PENDENT SPRINKLER VK572 (K14.0) TECHNICAL DATA
Page 1 of 6 1. DESCRIPTION Viking Standard/Quick Response Extended Coverage Ordinary Hazard (ECOH) Pendent Sprinkler VK572 is a thermosensitive glass bulb spray sprinkler with a 14.0 (202 metric*) nominal
More informationFIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.
15500 - FIRE PROTECTION PART I DESIGN GUIDELINES A. General 1. Vertical fire pumps shall not be used at the University. 2. coupling piping shall be permitted for sprinkler and standpipe systems only. B.
More informationstandard/quick response extended coverage light and ordinary hazard elo sprinklers
January 27, 2012 Sprinkler 83a 1. DESCRIPTION Viking EC/QREC Light and Ordinary Hazard Extra-Large Orifice Sprinklers VK532 and VK534 are thermosensitive spray sprinklers available in several different
More informationModel F1FR Series Quick Response Standard Spray
Model F1FR 56 Types Standard Upright Standard Pendent Model F1FR 56 Recessed Types Standard Pendent/F1/F2/FP Model F1FR 56 Concealed Types Standard Pendent Listing & Approvals 1. Underwriters Laboratories
More informationRefer to the specific sprinkler or spray nozzle technical data pages for sprinkler listings and approvals.
Page 1 of 5 1. DESCRIPTION A. Sprinkler Cabinets Viking sprinkler cabinets are metal enclosures constructed to store an emergency supply of spare sprinklers and a sprinkler installation wrench. NFPA 13
More informationstandard response/ quick response extended coverage
1. DESCRIPTION Viking Extended Coverage Adjustable Recessed Dry Pendent Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are designed for dry
More informationquick response Sprinkler 105a October 25, 2010
October 25, 2010 Sprinkler 105a 1. DESCRIPTION Viking Quick Response Dry Pendent Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are designed
More informationSTANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT UPRIGHT SPRINKLER VK535 (K11.2) TECHNICAL DATA
Page of 5. DESCRIPTION Viking EC/QREC Ordinary Hazard ELO Fusible Element Sprinkler VK535 is a thermosensitive spray sprinkler available in several different finishes and temperature ratings to meet varying
More informationstandard response dry horizontal sidewall sprinklers
February 24, 2012 Sprinkler 102a 1. DESCRIPTION Viking Standard Response Dry Horizontal Sidewall Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers
More informationISSUE. In This. Fabrication Services Now Available. Seminar Schedule January Viking Product Seminar 2003 Schedule
January 2003 210 N. Industrial Park Road Hastings, MI 49058 Phone: 877-384-5464 269-945-9501 Fax: 269-945-9599 Web: www.vikingsupplynet.com Fabrication Services Now Available Viking is excited to announce
More informationSECTION WET PIPE FIRE PROTECTION SPRINKLER SYSTEM
SECTION 213100 WET PIPE FIRE PROTECTION SPRINKLER SYSTEM PART 1 - GENERAL 1.01 GENERAL REQUIREMENTS A. The requirements of the General Conditions and Supplementary Conditions apply to all work herein.
More informationSTANDARD/QR EXTENDED COVERAGE LIGHT HAZARD TECHNICAL DATA ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617
May 14, 2010 Sprinkler 85h 1. DESCRIPTION Viking Standard/QREC Light Hazard ELO Fusible Element Pendent Sprinkler VK617 is a thermosensitive spray sprinkler available in several different finishes and
More informationAdditional Bulletins applicable to all F1RES LL Sprinklers Wall Wetting - Bulletin 007 Design and Installation - Bulletin 140
Bulletin 033 Rev. A Model F1 RES LL Residential s for Design Density of.05 gpm/ft 2 Bulletin 033 Rev. A Specifically Listed for use in Multipurpose Systems that serve both domestic water and fire protection.
More informationstandard response dry horizontal sidewall sprinklers
Sprinkler 102a 1. DESCRIPTION Viking Standard Response Dry Horizontal Sidewall Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are designed
More informationSpecialties Quality, Durability, Reliability. FIrE ProTECTIon
_specialties:pcsectiond_new 2/6/2012 4:46 PM Page -36 36 SECTIon Specialties Quality, Durability, Reliability FIrE ProTECTIon In addition to our plumbing business, LYNCAR has been a leading supplier to
More informationmirage standard response concealed pendent sprinkler vk492 (K5.6)
Page 1 of 6 1. DESCRIPTION Viking Mirage Standard Response Concealed Pendent Sprinkler VK492 is a thermosensitive glass-bulb spray sprinkler designed for installation on concealed pipe systems where the
More informationstandard response large orifice dry
February 26, 2014 Sprinkler 101o 1. DESCRIPTION Viking Standard Response Large Orifice Dry Pendent Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers
More informationFREEDOM RESIDENTIAL PENDENT LEAD FREE SPRINKLER VK4700 (K3.0) TECHNICAL DATA
Page 1 of 5 1. DESCRIPTION Viking Freedom Residential Pendent Lead Free* Sprinkler VK4700 is a thermosensitive, glassbulb residential sprinkler available in several different finishes and temperature ratings
More informationQUICK RESPONSE ELO PENDENT SPRINKLER VK377 (STORAGE-DENSITY/AREA) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.
Page 1 of 6 1. DESCRIPTION Viking Quick Response Extra-Large Orifice Pendent Sprinkler VK377 is a thermosensitive glass bulb spray sprinkler available in several different finishes and temperature ratings
More informationHORIZON STANDARD RESPONSE FLUSH PENDENT SPRINKLER VK400 TECHNICAL DATA
Page of 5. DESCRIPTION Viking Horizon Standard Response Flush Pendent Sprinkler VK400 is a small, flush, solder link and lever spray sprinkler. Designed for use with concealed piping, the unit is mounted
More informationSTANDARD/QUICK RESPONSE EXTENDED COVERAGE DRY HORIZONTAL SIDEWALL SPRINKLER TECHNICAL DATA
Page 1 of 6 1. DESCRIPTION Viking Standard/Quick Response Extended Coverage Dry Horizontal Sidewall Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers
More informationmirage Quick response extended coverage concealed pendent sprinklers (vk632 and vk634)
January 1, 2011 Sprinkler 92a 1. DESCRIPTION Viking Mirage Quick Response Extended Coverage Concealed Pendent Sprinkler VK632 and VK634 are thermosensitive glass-bulb spray sprinkler designed for installation
More informationTECHNICAL DATA. The Viking Corporation s Web site at Frame Casting: Brass UNS-C84400
Page 1 of 8 1. DESCRIPTION Viking Quick Response Dry Horizontal Sidewall Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are designed for dry
More informationSTANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK537 (K11.2) TECHNICAL DATA
Page 1 of 5 1. DESCRIPTION Viking EC/QREC Ordinary Hazard ELO Fusible Element Pendent Sprinkler VK537 is a thermosensitive spray sprinkler available in several different finishes and temperature ratings
More informationSTANDARD RESPONSE DRY PENDENT STANDARD ORIFICE SPRINKLERS TECHNICAL DATA
Page 1 of 7 1. DESCRIPTION Viking Standard Response Dry Pendent Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are designed for dry systems
More informationTECHNICAL DATA. Viking Technical Data may be found on Pip Cap: Brass UNS-C31400 or UNS-C31600
1. DESCRIPTION Viking Standard Response Dry Pendent Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are designed for dry systems and preaction
More informationSTANDARD RESPONSE DRY HORIZONTAL SIDEWALL SPRINKLERS TECHNICAL DATA
Page 1 of 9 1. DESCRIPTION Viking Standard Response Dry Horizontal Sidewall Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are designed for
More informationTECHNICAL DATA STANDARD/QUICK RESPONSE EXTENDED COVERAGE LIGHT HAZARD ELO PENDENT SPRINKLER VK608
Page 1 of 6 TECHNICAL DATA 1. DESCRIPTION The Viking Standard/Quick Response Extended Coverage Light Hazard Extra- Large Orifice (ECLH-ELO/QRECLH-ELO) Pendent Sprinkler VK608 is a thermosensitive spray
More informationC. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.
SECTION 218800 - FIRE PROTECTION 1. GENERAL A. Provisions of Division 1, GENERAL REQUIREMENTS, and Section 230000, MECHANICAL GENERAL CONDITIONS, and Section 230050, SEISMIC PROTECTION are a part of this
More informationstandard response dry horizontal sidewall sprinklers
Page 1 of 9 1. DESCRIPTION Viking Standard Response Dry Horizontal Sidewall Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are designed for
More informationTECHNICAL DATA STANDARD/QUICK RESPONSE EXTENDED COVERAGE PENDENT SPRINKLER VK534 (K11.2)
Page 1 of 6 1. DESCRIPTION Viking EC/QREC Pendent Sprinkler VK534 is a thermosensitive spray sprinkler available in several different finishes and temperature ratings to meet varying design requirements.
More informationThe Viking Corporation s Web site at Rated to 175 psi (12 bar) water working pressure
Sprinkler 41t 1. DESCRIPTION Viking Quick Response Upright and Pendent Sprinklers are small thermosensitive glass bulb spray available with various finishes and temperature ratings to meet design requirements.
More informationCubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM
SECTION 21 0000 AUTOMATIC FIRE SPRINKLER SYSTEM PART 1 GENERAL 1.1 QUALITY ASSURANCE A. Codes and Standards: 1. FBC (Florida Building Code 2015) 2. FBC (Florida Fire Code 2015) 3. NFPA #13R (Standard for
More informationquick response ordinary hazard dry hsw sprinklers (8.0K) (VK275, VK277, & VK279)
February 26, 2014 Sprinkler 106s 1. DESCRIPTION Viking Quick Response Ordinary Hazard Dry Horizontal Sidewall Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing.
More information1.1 Refer to Section for General Mechanical Requirements. 1.3 Refer to Section for Pipe and Equipment Identification Requirements.
FIRE PROTECTION GENERAL INFORMATION 1.1 Refer to Section 230000 for General Mechanical Requirements. 1.2 Refer to Section 230529 for Hangers and Supports. 1.3 Refer to Section 230553 for Pipe and Equipment
More informationViking Introduces Industry s First 14K Upright ESFR
On Fire August 2000 SupplyNet 210 N. Industrial Park Road Hastings, MI 49058 Phone: 877-384-5464 616-945-9501 Fax: 616-945-9599 Web: www.vikingsupplynet.com Viking Introduces Industry s First 14K Upright
More informationSTANDARD/QR EXTENDED COVERAGE LIGHT HAZARD ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617 TECHNICAL DATA
Page 1 of 6 1. DESCRIPTION Viking Standard/QREC Light Hazard ELO Fusible Element Pendent Sprinkler VK617 is a thermosensitive spray sprinkler available in several different finishes and temperature ratings
More informationFREEDOM RESIDENTIAL PENDENT SPRINKLER VK470 (K3.0) TECHNICAL DATA
Page 1 of 5 1. DESCRIPTION Viking Freedom Residential Pendent Sprinkler VK470 is a thermosensitive, glass-bulb residential sprinkler available in several different finishes and temperature ratings to meet
More informationDRY VERTICAL SIDEWALL SPRINKLERS TECHNICAL DATA
Page 1 of 6 1. DESCRIPTION Viking dry vertical sidewall sprinklers are suitable for use in areas subject to freezing. They may be installed either upright or pendent, and are suitable for use on dry systems,
More informationHORIZON QUICK RESPONSE FLUSH PENDENT SPRINKLERS TECHNICAL DATA
Sprinkler 53a 1. DESCRIPTION Viking Horizon Quick Response Flush Pendent Sprinklers are small, flush, solder link and lever spray sprinklers. Designed for use with concealed piping, the units are mounted
More informationCOBB COUNTY SCHOOLS /S&A % BID DOCUMENTS 2/18/11 SECTION SPRINKLER SYSTEM
SECTION 21 10 00 PART 1 - GENERAL 1.1 CODES A. Work shall conform to NFPA 13 Sprinkler Systems, 2002 Edition and NFPA 24 Outside Protection, 2002 Edition. NFPA 14 Standpipe Systems, 2000 Edition and International
More informationstandard response elo upright and pendent sprinklers (storage-density/area)
December 5, 2008 Sprinkler 13e 1. DESCRIPTION The Viking Standard Response ELO Upright and Pendent Sprinklers are thermosensitive glass bulb spray sprinklers available in several different finishes and
More informationmicrofast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)
February 13, 2009 Sprinkler 43a 1. DESCRIPTION Viking Microfast and MicrofastHP Quick Response Horizontal Sidewall Sprinklers are small thermosensitive glass bulb spray sprinklers available with various
More informationfreedom residential horizontal sidewall lead free sprinkler VK4840 (k4.2)
Page 1 of 5 1. DESCRIPTION Viking Freedom Residential Horizontal Sidewall Lead Free* Sprinkler VK4840 is a small, thermosensitive, glass-bulb residential sprinkler available in several different finishes
More informationTECHNICAL DATA. Refer to Approval Chart 1 and UL Design Criteria for culus Listing requirements that must be followed.
Page 1 of 5 1. DESCRIPTION Viking Standard Response Fusible Link Pendent Sprinkler VK008 is a small thermosensitive solder link spray sprinkler available with various finishes and temperature ratings to
More informationTECHNICAL DATA. 2. LISTINGS AND APPROVALS NOTE: Viking Dry Vertical Sidewall Sprinklers are NOT listed or approved. Sprinkler 103a.
September 6, 2012 Sprinkler 103a 1. DESCRIPTION Viking are suitable for use in areas subject to freezing. They may be installed either upright or pendent, and are suitable for use on dry systems, preaction
More informationTECHNICAL DATA. Viking Technical Data may be found on Maximum Working Pressure: 175 psi (12 Bar).
Page 1 of 6 1. DESCRIPTION Viking Mirage Quick Response Extended Coverage Concealed Pendent Sprinkler VK632 and VK634 are thermosensitive glass-bulb spray sprinkler designed for installation on concealed
More informationTECHNICAL DATA. UL/C-UL Listed as a standard response. horizontal ceilings. Listings up to a OBSOLETE
Sprinkler 42 a UL/C-UL Listed as a standard response sprinkler for use in Light Hazard occupancies with extended areas of coverage below smooth flat, horizontal ceilings. Listings up to a maximum of 250
More informationquick response horizontal sidewall sprinkler vk360 (K8.0)
February 26, 2010 Sprinkler 43o 1. DESCRIPTION Viking Quick Response Horizontal Sidewall Sprinkler VK360 is a thermosensitive glass bulb spray sprinkler available in several different finishes and temperature
More informationmicromatic standard sprinkler VK004 (K4.2) 3. technical data Page 1 of 6
Page 1 of 6 1. DESCRIPTION The Viking Micromatic Standard Response Pendent VK004 Sprinkler is a small, thermosensitive, glass-bulb spray sprinkler available in several different finishes and temperature
More informationMIRAGE STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA
Page 1 of 6 TECHNICAL DATA 1. DESCRIPTION Viking Mirage Standard and Quick Response Concealed Pendent Sprinkler VK462 and HP Sprinkler VK463 are thermosensitive glass-bulb spray sprinklers designed for
More informationSeries EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright and Pendent Extended Coverage Light and Ordinary Hazard General Description
Worldwide Contacts www.tyco-fire.com Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K and Pendent Extended Coverage Light and Ordinary Hazard General Description TYCO Series EC-11 and EC-14 Extended
More informationMIRAGE STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA
Page of 7 TECHNICAL DATA. DESCRIPTION Viking Mirage Standard and Quick Response Concealed Pendent VK6 and HP VK6 are thermosensitive glass-bulb spray sprinklers designed for installation on concealed pipe
More informationFREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK486 (K4.0) TECHNICAL DATA
Page 1 of 6 1. DESCRIPTION Viking Freedom Residential Horizontal Sidewall Sprinkler VK486 is a small, thermosensitive, glass-bulb residential sprinkler available in several different finishes and temperature
More informationqr fusible element sprinklers (part nos , 13959, 17535, and 17536) 3. technical data Sprinkler 42h March 14, 2013
March 14, 2013 Sprinkler 42h 1. DESCRIPTION Viking Quick Response Fusible Element Upright and Pendent Sprinklers are small thermosensitive solder link spray sprinklers available with various finishes and
More informationEC/QREC ORDINARY HAZARD UPRIGHT SPRINKLER VK570 (K14.0) TECHNICAL DATA
Page 1 of 5 1. DESCRIPTION Viking Standard/Quick Response Extended Coverage Ordinary Hazard (ECOH) Upright Sprinkler VK570 is a thermosensitive glass bulb spray sprinkler with a 14.0 (202 metric*) nominal
More informationSTANDARD RESPONSE FUSIBLE LINK PENDENT SPRINKLER VK008 (K4.2) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.
Page 1 of 5 1. DESCRIPTION Viking Standard Response Fusible Link Pendent Sprinkler VK008 is a small thermosensitive solder link spray sprinkler available with various finishes and temperature ratings to
More informationmirage Quick response concealed pendent sprinkler vk465 (K4.2)
January 1, 2011 Sprinkler 64a 1. DESCRIPTION Viking Mirage Quick Response Concealed Pendent Sprinkler VK465 is a thermosensitive glass-bulb spray sprinkler designed for installation on concealed pipe systems
More informationMIRAGE EC/QREC OH-ELO CONCEALED PENDENT SPRINKLER VK538 (K11.2) TECHNICAL DATA
Page 1 of 6 1. DESCRIPTION Viking Mirage EC/QREC ELO Concealed Pendent Sprinkler VK538 is a thermosensitive solder link spray sprinkler designed for installation on concealed pipe systems where the appearance
More informationFREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) TECHNICAL DATA
Page 1 of 5 1. DESCRIPTION Viking Freedom Residential Concealed Pendent VK494 is a small thermosensitive, glass-bulb residential sprinkler designed for installation on concealed pipe systems where the
More informationTECHNICAL DATA vk470 (K3.0)
Page 1 of 5 1. DESCRIPTION Viking Freedom Residential Pendent Sprinkler VK470 is a thermosensitive, glass-bulb residential sprinkler available in several different finishes and temperature ratings to meet
More informationsprinkler vk538 (K11.2)
December 6, 2012 Sprinkler 89h 1. DESCRIPTION Viking Mirage EC/QREC ELO Concealed Pendent Sprinkler VK538 is a thermosensitive solder link spray sprinkler designed for installation on concealed pipe systems
More informationMicrofastHP EC/QREC FUSIBLE ELEMENT HSW HIGH PRESSURE SPRINKLER VK613 (K5.6) TECHNICAL DATA
Page 1 of 6 1. DESCRIPTION The Viking Fusible Element Horizontal Sidewall Sprinkler VK613 is a small thermosensitive solder link spray sprinkler available with various finishes and temperature ratings
More informationSECTION DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE
SECTION 21 1316 DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE PART 1 GENERAL 1.01 SECTION INCLUDES A. Dry-pipe sprinkler system. B. System design, installation, and certification. C. Fire department
More informationUniversity of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL
SECTION 21 13 16 DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section
More informationFREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK479 (K3.0) TECHNICAL DATA
Page 1 of 6 1. DESCRIPTION Viking Freedom Residential Horizontal Sidewall Sprinkler VK479 is a small, thermosensitive, glass-bulb residential sprinkler available in several different finishes and temperature
More informationfreedom residential horizontal sidewall sprinkler Vk450 (k4.2)
January 13, 2012 Sprinkler 143m sprinkler Vk450 (k4.2) 1. DESCRIPTION Viking Freedom Residential Horizontal Sidewall Sprinkler VK450 is a small, thermosensitive, glass-bulb residential sprinkler available
More informationHORIZON MIRAGE QUICK RESPONSE LARGE ORIFICE CONCEALED PENDENT SPRINKLER VK406 TECHNICAL DATA
January 4, 2008 Sprinkler 57g 1. DESCRIPTION Viking Horizon Mirage Quick Response Large Orifice Concealed Pendent Sprinkler VK406 is a small solder link and lever spray sprinkler designed for installation
More informationfreedom residential pendent sprinkler vk466 (K5.2)
Page 1 of 5 1. DESCRIPTION Viking Freedom Residential Pendent Sprinkler VK4 is a thermosensitive, glass-bulb residential sprinkler available in several different finishes and temperature ratings to meet
More informationstandard response sprinklers (vk102 & vk202) 3. technical data Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Sprinkler 11j
April 22, 2011 Sprinkler 11j 1. DESCRIPTION Viking Standard Response Concealed Pendent Sprinklers are thermosensitive glass bulb spray sprinklers pre-assembled with a threaded adapter for installation
More informationVK3021 QUICK RESPONSE PENDENT SPRINKLER (K5.6) TECHNICAL DATA
Page 1 of 5 1. DESCRIPTION The Viking VK3021 Quick Response Pendent Sprinkler is a small thermosensitive glass bulb spray sprinkler available with various finishes and temperature ratings to meet design
More informationTECHNICAL DATA. 2. LISTINGS AND APPROVALS culus Listed: Category VNIV FM Approved: Class 2009 NYC Approved: MEA E, Volume 3
Page 1 of 6 TECHNICAL DATA 1. DESCRIPTION The Viking Standard Response ELO Pendent Sprinkler is a thermosensitive glass bulb spray sprinkler available in several different finishes and temperature ratings
More informationQUICK RESPONSE EXTENDED COVERAGE FUSIBLE ELEMENT PENDENT SPRINKLER VK601 (K5.6) TECHNICAL DATA
Page 1 of 6 1. DESCRIPTION Viking QREC Fusible Element Pendent Sprinkler VK601 is a thermosensitive solder link spray sprinkler available in several different finishes and temperature ratings to meet varying
More informationQuick response concealed horizontal sidewall sprinkler VK481
February 3, 2012 Sprinkler 63h 1. DESCRIPTION Viking Quick Response Concealed Horizontal Sidewall Sprinkler VK481 is a small solder link and lever spray sprinkler designed for installation on concealed
More informationSprinkler Identification Numbers
Worldwide Contacts www.tyco-fire.com Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K and Pendent Extended Coverage Light and Ordinary Hazard General Description Extended Coverage and Pendent Sprinklers
More informationstandard response elo upright sprinkler
Page of 5. DESCRIPTION The Viking Standard Response ELO Upright Sprinkler is a thermosensitive glass bulb spray sprinkler available in several different finishes and temperature ratings to meet design
More informationFREEDOM RESIDENTIAL PENDENT SPRINKLER VK468 (K4.9) TECHNICAL DATA
October 4, 2007 Sprinkler 149m Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION Viking Freedom Residential Pendent Sprinkler VK468
More informationfreedom residential concealed pendent sprinkler vk474 (K5.8)
Page of sprinkler vk7 (K5.) The Viking Corporation, 0 N Industrial Park Drive, Hastings MI 905 Telephone: 69-95-950 Technical Services: 77--56 Fax: 69--0 Email: techsvcs@vikingcorp.com. DESCRIPTION Viking
More informationMicrofast quick response Fusible element hsw sprinkler
Page 1 of 7 TECHNICAL DATA 1. DESCRIPTION The Viking Microfast Quick Response Fusible Element Horizontal Sidewall Sprinkler VK307 is a small thermosensitive solder link spray sprinkler available with various
More informationmicromatic standard sprinkler VK003 (K2.8) 3. technical data Page 1 of 7
Page 1 of 7 1. DESCRIPTION The Viking Micromatic Standard Response Pendent VK003 Sprinkler is a small, thermosensitive, glass-bulb spray sprinkler available in several different finishes and temperature
More informationTECHNICAL DATA. Page 1 of 6
Page 1 of 6 1. DESCRIPTION Viking Quick Response Horizontal Sidewall Sprinkler VK360 is a thermosensitive glass bulb spray sprinkler available in several different finishes and temperature ratings to meet
More informationModel F3-80 Dry K8.0 (115 metric) Standard-Response, Standard Spray Sprinklers
Bulletin 060 Rev. A Bulletin 060 Rev. A Model F3-80 Dry K8.0 (115 metric) Standard-Response, Standard Spray Sprinklers Features 1. Available in the following configurations: Pendent with standard escutcheon
More informationESCUTCHEON PLATE SEATING SURFACE. 1-11/16" (42,7 mm) CROSS SECTION
Worldwide Contacts www.tyco-fire.com Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K and Pendent Extended Coverage Light and Ordinary Hazard General Description Extended Coverage and Pendent Sprinklers
More informationfreedom residential concealed pendent sprinkler VK488 (K3.0)
Page 1 of 6 sprinkler VK (K3.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 905 1. DESCRIPTION Viking Freedom Residential Concealed Pendent Sprinkler VK is a small highsensitivity
More informationTECHNICAL DATA. Refer to the Approval Chart and Design Criteria for C-UL-US-EU Listing requirements that must be followed.
Page 1 of 6 1. DESCRIPTION Viking Freedom Residential Horizontal Sidewall Sprinkler VK486 is a small, thermosensitive, glass-bulb residential sprinkler available in several different finishes and temperature
More informationDecember 14, 2015 Page 1 of 7 TECHNICAL DATA
December 14, 015 Page 1 of 7 1. DESCRIPTION Viking Standard Response/Quick Response Extended Coverage Dry Concealed Pendent s are thermosensitive spray sprinklers suitable for use in areas subject to freezing.
More informationTECHNICAL DATA OBSOLETE
November 2, 2007 Sprinkler 113a 1. DESCRIPTION The Viking Standard Response High Challenge Upright Large-Drop Sprinkler VK540 is a thermosensitive, glass-bulb sprinkler intended for use in protecting high
More informationA Newsletter for Fire Sprinkler Contractors Vol 9 Issue 2
On Fire April 2004 210 N. Industrial Park Road Hastings, MI 49058 Phone: 877-384-5464 269-945-9501 Fax: 269-945-9599 Web: www.vikingsupplynet.com A Newsletter for Fire Sprinkler Contractors Vol 9 Issue
More informationFREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK460 (K5.8) TECHNICAL DATA
Page 1 of Telephone: 29-945-9501 Technical Services: 8-384-544 Fax: 29-818-180 Email: techsvcs@vikingcorp.com 1. DESCRIPTION Viking Freedom Residential Horizontal Sidewall Sprinkler VK40 is a small, thermosensitive,
More informationStandard Spray concealed horizontal sidewall sprinkler VK481
Page 1 of 6 1. DESCRIPTION Viking Quick Response Concealed Horizontal Sidewall VK481 is a small solder link and lever spray sprinkler designed for installation on concealed pipe systems. The sprinkler
More informationFREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK498 (K5.8) TECHNICAL DATA
Page 1 of 5 1. DESCRIPTION Viking Freedom Residential Concealed Pendent VK498 is a small thermosensitive, glass-bulb residential sprinkler designed for installation on concealed pipe systems where the
More information