1 RP10, RP10A & RP10A+ Efficiency, Reliability, Simplicity

2 NEATPORT PTY. LTD. TRADING AS SUNCOAST WASTE WATER MANAGEMENT (A.B.N ) 59 Industrial Avenue, Kunda Park, Queensland 4556, Australia Phone: info@ozzikleen.com Web: Document No.: P002 Page 2 of 24 Date: 12/01/2018

3 CONGRATULATIONS We would like to thank you for investing in an Ozzi Kleen sewage treatment plant. An Ozzi Kleen treatment plant consists of a single tank using a cyclic aerobic biological treatment process, designed to take all of your household waste water; i.e. toilets, bathrooms, kitchen and laundry. The effluent is then disinfected and may be reused on your garden. Consider your Ozzi Kleen treatment plant as a small farm of micro-organisms consuming the waste that is discharged into it. Normal household waste water will be biologically treated to produce high quality treated water which may be reused. Suncoast Waste Water Management specialize in domestic and commercial water and waste water solutions. Keep it GREEN with Ozzi Kleen - The Water & Waste Water Professionals Ozzi Kleen products made here in Australia offer a unique range of advanced product technologies to recycle and reuse water. We are a family owned and operated company, providing sewage treatment solutions to Australian households and commercial operations since Ranging from the original and trusted Ozzi Kleen Domestic Household Sewage Treatment Plant (HSTP) to: Greywater Treatment Systems Underground and Above Ground Rainwater Harvesting Tank Systems Commercial Waste Water Treatment Systems Transportable Treatment Plants Pump Stations Grease Traps Visit for more information on your Ozzi Kleen Waste Water Treatment System and our range of other products. Document No.: P002 Page 3 of 24 Date: 12/01/2018

4 TABLE OF CONTENTS STATEMENT... 5 MODELS AVAILABLE... 5 OZZI KLEEN MANUFACTURER S WARRANTY... 6 INSTALLATION INSTRUCTIONS... 7 PLUMBER'S INSTALLATION INSTRUCTIONS...7 In-ground installation diagram...8 Plumber s installation check list in-ground installation...9 ELECTRICAL REQUIREMENTS (COPY ONLY) INSTALLATION INSTRUCTIONS...10 Alarm panel diagram...11 In House Remote Alarm Panel...12 Buzzer Mute Function...12 HOW THE OZZI KLEEN TREATMENT PLANT WORKS OPERATING INSTRUCTIONS...14 TREATMENT PLANT SERVICING TROUBLESHOOTING GUIDE SPECIFICATIONS SYSTEM DIAGRAM...20 SYSTEM FLOW DIAGRAM...21 SAFETY INFORMATION Document No.: P002 Page 4 of 24 Date: 12/01/2018

5 INTERPRETATION (i) (ii) 'Manufacturer' includes Neatport Pty. Ltd. A.B.N trading as Suncoast Waste Water Management. 'Purchaser/Owner' shall mean the registered proprietor of the property where the Ozzi Kleen Sewage treatment plant has been installed. STATEMENT We, the manufacturer of the OZZI KLEEN sewage treatment systems, confirm that our treatment plants meet the requirements of the State Regulatory Authorities. This equipment is covered under a manufacturer's warranty as per the warranty conditions on page 6 of the Owner's Manual. This system has been designed to treat normal household sewage to the required standards as set by the State Regulatory Authorities. This also precludes any use of garbage grinders connected to the system. The waste water discharged to the system should not contain foreign matter such as: disposable nappies, wipes, tampons, sanitary napkins, condoms, plastics, paint, thinners, contents of a portable chemical toilet, or waste from garbage grinders, etc. The wastewater should not contain excessive amounts of harsh cleaners, disinfectants, fats, oils or grease. This manual is for owners of the OZZI KLEEN system, which describes the proper function of the treatment plant, operating and maintenance responsibilities of the Owner and authorised personnel, and any service-related obligations of the Manufacturer. MODELS AVAILABLE Models Available: RP10 (Standard) RP10A (Advanced) RP10A+ (Advanced with Nutrient Reduction) Optional Upgrade: High Pressure Pump Sock Filtration U.V. Disinfection Document No.: P002 Page 5 of 24 Date: 12/01/2018

6 OZZI KLEEN MANUFACTURER S WARRANTY Warranty is subject to the return of both a signed Plumber s Installation Certificate and Commissioning Certificate. These Certificates are to be filled out and returned to the manufacturer as part of the Owner's Warranty Registration. If the Commissioning Certificate and Plumber s Installation Certificate have not been returned to Ozzi Kleen the warranty claim may be rejected and all warranty terms may become void. 1. Suncoast Waste Water Management (SWWM) warrants to the original purchaser that all equipment manufactured by SWWM is free from defect in material and construction at the time of dispatch from the premises of SWWM. 2. This warranty is a return to base warranty which means the item must be returned to the manufacture for repair. An exchange unit may be provided in this case. An Ozzi Kleen approved Green Card Service Agent must be used to service the system in order to maintain warranty. By not doing so, you may void the warranty. A list of Approved Green Card Service Agents is available on the Ozzi Kleen website. If replacement or service under this warranty policy is required and distance prevents you calling personally, forward your product freight prepaid to your nearest Ozzi Kleen authorised Service Provider. Warranty claims relating to the Submersible Pump should be directed to Ascento on This warranty does not extend to any claim made after a fixed period from the date of purchase for the following equipment: Main Tank 15 years Electronic Control Box 36 months Electrical components 12 months Air Blower 36 months Submersible Pump 36 months 4. All claims for warranty must be done through the retailer or supplier from whom the product was purchased. Proof of purchase must be supplied. 5. Any claim made in relation to this warranty is limited to the cost of replacement equipment or such parts that are defective labour/travel expenses are not included. 6. In the case of parts not manufactured by SWWM such as submersible pump, air blower etc., the guarantee of warranty extended to the purchaser will be limited to the guarantee or warranty available from the manufacturer of that component. 7. This warranty is valid only when the equipment has been used in accordance with the Owner's Manual and serviced by a duly authorised Ozzi Kleen Service Provider every three months. 8. This warranty does not cover any equipment that has been improperly installed, misused, neglected, damaged in transport, repaired without the authorisation of SWWM or altered in any way from its original condition at the date of purchase. 9. Adverse operating conditions beyond the control of SWWM such as improper voltage, water pressure, excessive ambient temperature, water damage, flooding, pest or insect invasion, or any condition that adversely affects the performance or life of the equipment will render this warranty null and void. 10. Any costs incurred to repair a unit that is not covered by warranty will be passed on to the consumer including costs incurred to remove the faulty unit and replace with an exchange unit. SWWM is not responsible for any costs for goods not covered by this warranty. 11. Warranty work will not be performed until the customer has accepted the price quoted for the service call. SWWM will designate a minimum charge. Warranty does not cover Cleaning of any blockages or damage to equipment caused by not clearing blockages Any operational problems due to extraneous matter, fats, oils or chemical spills in the sewage Any foreign material or calcium build up problems caused from water supply to the system Insect or pest invasion causing damage to electrical or mechanical parts If the system has been used as an external power supply for other electrical appliances Electrical surges, brown outs, lightning strikes or abnormal voltages Service provider's time for replacement of any faulty parts or cleaning out of system Service provider's travel expenses (vehicle and travel time) Service callout costs Postage or courier charges to and from SWWM Document No.: P002 Page 6 of 24 Date: 12/01/2018

7 INSTALLATION INSTRUCTIONS * Extract from Installation Manual - supplied with system, found in motor box. PLUMBER'S INSTALLATION INSTRUCTIONS A hole for installation will have to be excavated approximately 2.5 m across and 2.4 m deep with a sound base. A layer of bedding sand is required (refer to drawing). If the hole is over excavated, extra bedding sand will be required. A normal installation of the treatment plant will locate the level of the sewer invert at 700mm below natural ground level and 1600mm above the sand base. 1. Install the treatment plant so that the tank is located centrally in the excavated hole with no less than 250mm to the nearest side. Ensure that the backfill is placed evenly around the tank (see drawing). If the system is placed unevenly in the hole so that the tank is near to touching a side of the hole, this will not allow for even backfill and cause tank instability and will have to be rectified by the installer. 2. Install the treatment plant so that the base of the green motor box is no less than 50mm above the natural ground level to avoid surface water entry. If the system is installed too low it will have to be rectified by the installer. 3. The Ozzi Kleen treatment plant is to be completely filled with water (approximately 4,500litres) or up to the sewer inlet before any backfill is placed around the tank. All compartments including sludge waste and effluent compartments must be filled as well. Failure to do so will cause tank instability and any deflection to the tank will have to be rectified by the installer. 4. The system is to be installed in a position where local storm water flooding and ponding around the tank will not occur. If the system is installed in a watercourse or a flood prone area the system will have to be relocated by the installer. 5. Landscaping or the importation of topsoil that is placed around the system after it is installed, which would cause the tank to be too low in the ground is to be avoided. No rocks are to be placed on top of the system or within 1m of the system. Imported topsoil that may be placed on the system after the installation will be the responsibility of the installer or owner. 6. When installing the system underneath a building ensure that there is sufficient head room for servicing. A minimum of 1200mm head room is needed for the service removal of some parts and retrieving of water samples at time of service. 7. Check all floor waste gullies are filled with water and location of drainage vents which should be located at the extreme end of the drainage system. 8. Where the treatment plant has been installed above ground level, please ensure a portable scaffold ladder compliant with AS/NZS No. AS is installed to allow commissioning and service access. Document No.: P002 Page 7 of 24 Date: 12/01/2018

8 In-ground installation diagram Document No.: P002 Page 8 of 24 Date: 12/01/2018

9 Plumber s installation check list in-ground installation The Ozzi Kleen sewage treatment system must be installed as per the following instructions. This form is to be filled out and returned to the manufacturer or their Distributor as part of the owner s warranty registration. PLEASE TICK ALL THE BOXES DURING THE INSTALLATION 1. Identify where the system is to be installed 2. Excavate hole 2500 mm diameter and approximately 2400 mm deep 3. Place a layer of bedding sand in the hole 4. Check depth from sand bed to natural ground level no greater than 2300 mm 5. Install the tank 6. Measure : Check depth from sewer invert to bedding sand no greater than 1600 mm Check depth of sewer invert to natural ground level no greater than 700 mm Check that motor box hinges are at least 50 mm above the natural ground level 7. Fill all tanks followed by main tank to sewer inlet with approximately 4,500 litres of water 8. Connect sewer piping to the sewer inlet 9. Backfill around tank with clean earth only, which is free from large lumps of clay, stones, bricks, foreign objects, or dumped rubbish etc. 10. Sock filter non-return valve and pressure gauge fitted (Sock filter systems only) 11. The irrigation system could be of several different formats, check Council requirements 12. Complete installation certificate located on back page Document No.: P002 Page 9 of 24 Date: 12/01/2018

10 ELECTRICAL REQUIREMENTS (COPY ONLY) A Licensed Electrican Must Be Used Installation of power to this unit must be performed by a licensed electrical contractor in accordance with current electricity act. INSTALLATION INSTRUCTIONS The power supply to the Treatment Plant is a single phase, 240V 50Hz supply and should be wired in 2.5mm² cable. The alarm circuit is supplied from the control board and is 24 V DC. As the alarm cables are run with the supply cables to the plant, they must be rated for 240V but may be 1mm² cable. The maximum power consumption of the Treatment Plant with standard settings is approximately 600 Watts. The air blower is rated at 80 Watts. The effluent pump is rated at up to 400 Watts, unless upgraded. The power supply to the system should come direct from the meter board and be protected by a 10 A RCD (Residual Current Device) and surge protection. The main power point needs to be RCD protected. It is recommended that the system be connected to an individual dedicated electrical circuit. The alarm mute switch and alarm lights are on a common switch plate, which is to be mounted in the Owner's house at an appropriate point. The switch plate is found in the motor box. There are 3 alarms available, all of which are activated via the Ozzi Kleen colour coded 4 core alarm cable (supplied separately). The alarm connections are polarity sensitive and must be connected correctly. Cabling between the dwelling and Treatment Plant should be installed using adequate protection/conduit. 2 cables will be required - 3 core for power supply and 4 core for alarm circuit. Important: if installing alarm cable in same conduit as the power supply, the 4 core alarm cable must be suitably rated. The power supply cable is brought into the sewage treatment system through the side of the tank turret at the top of the tank, referred to as the access manhole, and up through the floor of the motor box housed in the flexible conduit provided. The 240V supply is to be connected to the main power outlet inside the motor box. The low voltage alarm wires are to be connected to the terminals inside the small round junction box below the main power outlet. The external electrical conduit to the system is to be 25mm. The power supply cable is to be connected to weatherproof outlet provided and alarm cable to be connected to terminal strip inside of PVC junction box provided. No other connections are required. POWER TO TREATMENT PLANT MUST BE DISABLED BEFORE WIRING ALARM PANEL Document No.: P002 Page 10 of 24 Date: 12/01/2018

11 Alarm panel diagram 4 Core Alarm Wire RED YELLOW GREEN BLUE Mute (GREEN) 24V DC - LOOP (BLUE) 24V DC + Terminal Strip (RED) 24V DC + Common (YELLOW) Alarm Panel Wiring Diagram Red - Terminal strip on alarm panel Yellow - Common on the mute switch Blue - Loop on the mute switch Green - 1 on the mute switch A strobe light is connected to the yellow and blue alarm wires but please note that these wires are polarity sensitive. Yellow Blue + (positive) - (negative) Note: The motor compartment on the top of the sewage treatment system is on a hinged lid and the wiring to this compartment passes through a flexible conduit provided. No external conduit or rigid conduit is to be fastened to the outside of the motor box. If extra flexible conduit is used for wire connection to the system, ensure that there is sufficient length to allow for the tilting of the motor box when it is opened. Document No.: P002 Page 11 of 24 Date: 12/01/2018

12 In House Remote Alarm Panel The alarm panel s primary purpose is to indicate a high water alarm, low air alarm or power failure. When the alarm light is on continually this indicates there is power to the system and the system is healthy. If the alarm light is not on this would indicate that there is no power to the system. If the buzzer is muted the light will still indicate an alarm. High Water Alarm If the alarm light flashes fast (every ½ sec) this indicates that there is a high water alarm. Low Air Alarm If the alarm flashes slow (every 3sec) this indicates that there is a low air alarm. Buzzer Mute Function The buzzer mute function is activated when the alarm is on and the mute button is pressed on the alarm panel. Once the mute button has been pressed the buzzer will be muted for 10 hours or until the reset button on the OK 1 controller has been pressed. Document No.: P002 Page 12 of 24 Date: 12/01/2018

13 HOW THE OZZI KLEEN TREATMENT PLANT WORKS The OZZI KLEEN STP operates through a cycled aeration process designed to treat all the household sewage; i.e. sewage from toilets, bathrooms, kitchen and laundry. The process is similar to the tried and tested method used in municipal treatment plants. The waste products in the sewage are completely consumed by naturally occurring bacteria in the oxygen-rich environment in the aeration tank. The system treats the organic waste to produce treated water to a high standard. The cycled aeration system process consists of three main cycles:- Aeration Cycle The incoming sewage is aerated and oxygenated with air supplied by the air blower. As aeration takes place, an aerobic environment is provided for micro-organisms. These organisms grow and establish an activated sludge. The activated sludge will oxidise the organic waste as long as a balance between the air feed and the organic/hydraulic load is maintained. Settling Cycle After the aeration cycle, aeration ceases for approximately 30 minutes, allowing the activated sludge to settle to the bottom of the aeration tank. A layer of clear water is then formed at the top of the aeration tank. Decanting Cycle After a predetermined settling period, a decanting operation takes place. The decanter device draws off effluent from the top of the aeration tank. The decanting cycle continues until either the liquid level in the tank reaches the minimum level, or the process timer puts the system back into the aeration treatment cycle, which in turn stops the decanting cycle. While decanting, the effluent is chlorinated and stored in the effluent holding tank for a short period to ensure disinfection of pathogenic organisms prior to discharge. When the liquid level is sufficient, the effluent pump will pump out the disinfected effluent (through the sock filter, if fitted) to the irrigation area. This water is then used for irrigating lawns and gardens, etc. Optional Sock Filtration If a sock filter is fitted to the system, the chlorinated effluent is pumped from the effluent holding tank through the sock filter. The sock filter operates under pressure, which is normally around 80 kpa. If the operating pressure goes higher than this, it could indicate that the filter needs a cleaning. NOTE: Max operating pressure 250kPa Advanced Treatment, RP10A & RP10A+ Only Advanced water treatment and nutrient reduction is achieved by chemical dosing and is checked by the Service Provider at each treatment plant service. Document No.: P002 Page 13 of 24 Date: 12/01/2018

14 OPERATING INSTRUCTIONS The treatment plant has to be commissioned to ensure that the system is set up correctly and is operating and ready for use. The system must not be used until it is fully commissioned. The Service Provider or duly authorised personnel will carry out commissioning. Regularly check that the irrigation system is working properly (if sprinklers are fitted). Check and clean regularly, making sure they are operating. Where a filter is installed (including disc and sock filters) please consult your Green Card Accredited Ozzi Kleen Service technician how best to clean and maintain your filter in between services. Maintaining the filter and irrigation area may be a weekly occurrence. The slow release chlorine tablets supplied should be sufficient for the period between services. Normally two kilograms of chlorine is placed in the system at each service. If the tablets have been consumed before the next service, more chlorine tablets will have to be added. Contact the Service Provider for replacement tablets, or obtain your own from a local supermarket or pool shop (jumbo pool chlorine tablets). Avoid inhalation of chlorine. Keep the area around the treatment plant in a clean state, to avoid any damage to the treatment plant from fires, vehicular traffic etc. The ground level around the irrigation outlet pipe may subside, causing a load on the pipe. Please ensure that the pipe is not pulled out of the tank by soil movement. DON'TS: For your own convenience there are a number of DON'TS that you should be made aware of: Do not discharge any items to the treatment plant that cannot be biologically broken down or are not a source of food for the micro-organisms i.e.: Disposable nappies, wipes, tampons, sanitary napkins, condoms, plastics, paint, thinners, contents of a portable chemical toilet, or any other foreign matter. Large quantities of harsh cleaners, disinfectants, or any other substances or poisons that would be harmful to your system's ecology. Preferably use bio- degradable products as this will also help the environment). Excessive amounts of fats, oils or grease, as this may cause problems within the biological treatment process. Fats have a calorific value of over 57,000 times that of normal sewage. Food scraps or the use of a garbage grinder, as this will increase the biological load on the system and could cause overloading. As the owner of your treatment plant, it is to your advantage to understand the operating principles of the system and be observant as to what is happening from day to day. Look after your treatment plant and it will serve you well. Document No.: P002 Page 14 of 24 Date: 12/01/2018

15 Note: If the Treatment Plant process has been disinfected, power disconnected or if any of the previously stated Don'ts on page 14 are put into the system, charges may apply for the Service Provider to rectify the problem. The Treatment Plant is never to be emptied without prior consent by the Manufacturer /Service Provider. Unplug Air Blower before tilting motor box to avoid internal damage to the Air Blower. The Main Switch is to be left on at all times. In the event of power failure, you should avoid using your household amenities in excess, as there would be no effluent pumped out and the system will overflow. Storage volume is approximately 1,000 litres. In the event of operational problems you should contact your Service Provider who will ensure that the situation is corrected after determining the fault or cause. Foaming: Foaming may occur with a new system due to laundry suds. The system operates initially with aeration of clean water, so with the addition of soaps it can sometimes cause a foaming effect. The system requires bio-solids and this will take effect in a few days after normal household use and will overcome foaming. This may be avoided by reducing excessive washing activity on a newly commissioned system. As a suggestion you may wish to put a sign in your toilet room for others that do not know the type of treatment system, warning them of the items that cannot be placed in the system. It may help to provide a small bin for foreign matter, such as sanitary items. If you are at any time renting out your property, please advise the tenants of the operating procedures. Ask your Service Provider for signage options or visit VACATION OF PREMISES If you are vacating your premises for a period greater than 6 months, please contact your local authorised Ozzi Kleen Service Provider. Your Service Provider will be able to advise you of the appropriate measures to take on vacating your premises. On your return, contact your authorised Ozzi Kleen Service Provider for re-commissioning of the system. (Only in the event it has been turned off) Document No.: P002 Page 15 of 24 Date: 12/01/2018

16 TREATMENT PLANT SERVICING The Ozzi Kleen system is to be serviced every 3 months, in accordance with State and Territory regulatory authorities. A test report is to be completed by an authorised Ozzi Kleen Service Provider on each service, and supplied to the Purchaser/Owner and Local Authority. This report outlines water quality tests performed, plant operation and condition of the irrigation area. The Purchaser/Owner is required to enter into a maintenance agreement for the servicing of the Ozzi Kleen Sewage Treatment Plant. The authorised representative must inform the Owner of their obligations to maintain a service contract. All servicing should be carried out by the authorised Ozzi Kleen Service Provider, holding a valid Green Card, or by any person or persons duly authorised in writing by the Manufacturer. A list of authorised Ozzi Kleen Service Providers can be found at or by contacting Ozzi Kleen s head office on The Purchaser/Owner shall provide reasonable access to the treatment plant as necessary to carry out the regular servicing as described within this Owner s Manual. Chlorine tablets are replenished with each service. The amount of chlorine replaced is dependent on the consumption, so that at the time of each service the chlorinator will be topped up so that there will be at least two kilograms of tablets left in the system. If the chlorine usage is higher, there is provision to hold up to four kilograms in the system. Sludge levels are monitored by the Service Provider, who will carry out removal of sludge if required. Note: In the event of any service queries, please refer directly to your local authorised Ozzi Kleen Service Provider. Suncoast Waste Water Management will not be responsible for faults if your system has not been serviced on the regular 3 month schedule. It is the responsibility of the Owner to ensure that a service is performed. Contact Suncoast Waste Water Management if your Service Provider is not contactable. Document No.: P002 Page 16 of 24 Date: 12/01/2018

17 TROUBLESHOOTING GUIDE Note: Check that the sprinkler system is not blocked before requesting a service call. Sprinklers must operate at all times. The treatment plant has an audio-visual, in-house alarm panel mounted inside your home. The alarm has a mute switch, which can be turned off until the problem is rectified. If the alarm situation is not addressed within 10 hours, the alarm will reactivate. In the event of any troubleshooting queries, please refer directly to your local authorised Ozzi Kleen Service Provider. OPERATION PROBLEM CAUSE REMEDY 1. High Water Alarm - buzzer will sound and the LED will flash fast a) High sewage flow discharging into treatment plant. High wash load, draining of spa bath, etc. b) Basket strainer blocked. c) Decant pipe blocked. d) Chlorinator blocked. e) Effluent pump fails to run when pump well is full. i) No power supply. ii) Float switch stuck. iii) Electrical fault in motor. f) Blocked sprinklers. g) (Optional) Sock filter may need cleaning. a) The plant will automatically go into settling and then decant mode. After approximately 30 minutes, the effluent pump should start and then the alarm should cancel. b) Clear any blockages. c) Clear any blockages. d) Clear any blockages. e) Effluent pump checks: i) Check plug and power supply. ii) Check that float switch is free to operate in pump well. iii) Call Service Provider. f) Check irrigation sprinklers. Clear any blockages. g) Empty and clean sockfilter. 2. Blower Alarm buzzer will sound and the LED will flash slow (see following page for further details) a) Broken or damaged air lines causing low air pressure. b) Air diffusers ruptured. c) Faulty blower components. d) Blower protection switch activated a) Call Service Provider. b) Call Service Provider. c) Call Service Provider. d) Call Service Provider. Document No.: P002 Page 17 of 24 Date: 12/01/2018

18 OPERATION PROBLEM CAUSE REMEDY 3. Treatment Plant Smelling a) Power turned off due to alarm being activated. b) Plant biomass killed-off. c) Blocked sprinklers causing ongoing high level alarm condition. d) Diffusers blocked causing loss of aeration. e) Diffuser partly ruptured causing poor aeration. f) Plant put into use prior to commissioning. g) Excessive fat/oil/grease or food scrap entry. a) Always leave power on. b) Advise Service Provider. The biomass may be killed-off by toxic chemicals discharged to the system; i.e. harsh cleaners, portable chemical toilet contents, excessive antibiotics, etc. Aeration tank may need to be pumped out and refilled with clean water c) Check sprinklers. Clear any blockages. An ongoing high level alarm condition will stop the treatment process. Extended alarm periods will result in loss of treatment, causing odours. d) Call Service Provider. e) Call Service Provider. f) Do not use treatment plant before commissioning. Septic, anaerobic conditions in the treatment plant will cause odours. Call Supplier/Service Provider. g) Dispose of fats/oils/grease or food scraps elsewhere. Contact your Service Provider for further advice. 4. Chlorine odour escaping through drainage. a) Pipes not installed correctly and filled with water and/or house drains and gully traps not filled with water. a) Check gully traps are full of water. b) Check the location of the drainage vent pipe. c) Call your plumber/drainer Note: The Red LED will always stay on constantly when there are no system faults and there is power to the system. If the red LED is off this would indicate that there is no power to the system. Document No.: P002 Page 18 of 24 Date: 12/01/2018

19 SPECIFICATIONS Parameter Wastewater treatment capacity Maximum hydraulic load Biological Oxygen Demand (BOD5) Total Suspended Solids (TSS) Fats, Oils and Grease (FOG) ph 6 < ph < 10 Wastewater temperature range 10ºC to 38ºC Raw Wastewater Characteristics 10 persons EP at 200 L/person/day 2,000 L/day 350 mg/l or 70 g/day/person 350 mg/l or 70 g/day/person 75 mg/l. For restaurant applications, a grease trap must be fitted upstream of the treatment plant to remove grease and oils. Treatment Plant Construction: Tank and components Polyethylene (MDPE) All Pipe work PVC Electrical Equipment: Air Blower AP80H Effluent Pump Submersible Controls Electronic (OK1 Control Board) Alarm System: Alarm System 24VDC Audio/Visual Alarm signal Indicator for High Water, Power & Blower Aeration Tank: Operating Volume 4.1m 3 Aeration tank volume 5.3 m 3 Residence time 46 hr Buffer Zone 1m 3 (approx.) Disinfection equipment: Chlorinator Type Tablet Dispenser Cassette Chlorine min contact time (max flow) 30 min Motor Box: Equipment Contained Air Blower, Control Board, Decanter, Solenoid Valve equipment Effluent Pump (standard): Effluent pump duty m head Pump Mounting Suspended on discharge pipe Optional Equipment Sock Filtration Equipment: Flow rate 250litre/min Max Pressure 250kPa Max Nutrient Reduction Equipment: Process control Electronic Phosphate reduction process Chemical dosing / Sludge wasting Sock Filters 120/210/Other Microns Lifting/Pump Stations SLS250, PT500, other sizes available Other Customization available Please enquire Irrigation Equipment: Basic irrigation equipment is supplied with the treatment plant. The irrigation system could be of several different formats. Check with Local Authority requirements. Document No.: P002 Page 19 of 24 Date: 12/01/2018

20 SYSTEM DIAGRAM Document No.: P002 Page 20 of 24 Date: 12/01/2018

21 SYSTEM FLOW DIAGRAM Document No.: P002 Page 21 of 24 Date: 12/01/2018

22 SAFETY INFORMATION Never enter any compartment of the treatment plant. There could be potential hazards from: Drowning in the tanks, Asphyxiation from an oxygen depleted atmosphere within the tanks. There are five accessible compartments: The motor box control compartment, which is accessible through the top lid. The main aeration tank, which is accessible by tilting the motor box on its hinges. The effluent tank with its pump, which is accessible through one of the large round lids. The sludge waste tank, which is accessible through the other large round lid. The chlorinator, which is accessible through the small round lid between the motor box and effluent tank. All access lids are normally secured with set screws. The Owner should ensure that they are all in place after any site inspection has been carried out. Signs indicating that the treated water is recycled and is not fit for drinking have been provided and are to be erected in the irrigation area. This is a State Regulatory Authority requirement in all areas. The Ozzi Kleen system operates on a 240 V power supply. The main power outlets within the motor box are intended for the use of the treatment plant equipment only. These should be kept plugged in at all times. The power outlets cannot be used for any other power appliances. Plugging anything else into these outlets will affect the systems controls, and may void warranty. Ensure all household drains are never dry. Check with your plumber that they have been installed correctly. Floor waste gully traps in your home require to be charged with water to prevent odours from the drains. If odours occur have your plumbing checked. Document No.: P002 Page 22 of 24 Date: 12/01/2018

23 Document No.: P002 Page 23 of 24 Date: 12/01/2018

24 Please contact your Ozzi Kleen Service Provider with any queries Manufactured by: Suncoast Waste Water Management A.B.N Industrial Avenue, Kunda Park, QLD, 4556 Head Office: (07) RP10, RP10A & RP10A+ Efficiency, Reliability, Simplicity

Owners Instruction Manual

Owners Instruction Manual Owners Instruction Manual Ultra Clear WASTE WATER TREATMENT SYSTEMS Domestic Single Tank Systems Contents Page Foreword 1 Description & Function Primary Treatment Aerobic Treatment Sludge Return Surge

More information

Your Pressure Sewer System. A Homeowner s Guide

Your Pressure Sewer System. A Homeowner s Guide Your Pressure Sewer System A Homeowner s Guide Your Pressure Sewer System A Homeowner s Guide CONTENTS Using this manual 2 Why install a pressure sewer system? 2 What is a pressure sewer system? 3 What

More information

Owners Manual - Incorporating Operation, Maintenance and Troubleshooting

Owners Manual - Incorporating Operation, Maintenance and Troubleshooting B-Series Advanced Wastewater Treatment Units www.bluewateratu.ca Owners Manual - Incorporating Operation, Maintenance and Troubleshooting Tel: 1 877 702 4634 Certified to NSF/ANSI Standard 40, Class 1

More information

USING YOUR PRESSURE SEWER SYSTEM

USING YOUR PRESSURE SEWER SYSTEM USING YOUR PRESSURE SEWER SYSTEM A homeowner s manual About this manual This manual will assist you with the operation and maintenance of the pressure sewer system installed on your property. We strongly

More information

EVAPOCYCLE OWNERS MANUAL

EVAPOCYCLE OWNERS MANUAL EVAPOCYCLE OWNERS MANUAL Introduction. The Aim of this manual to provide information to the property owner or occupant of the land on which an Evapocycle System has been constructed to insure that the

More information

YOUR PRESSURE SEWER SYSTEM

YOUR PRESSURE SEWER SYSTEM YOUR PRESSURE SEWER SYSTEM An owner s guide YOUR COPY TO KEEP CONTENTS What do I need to know about pressure sewer systems? Why install a pressure sewer system? What components make up a pressure sewer

More information

OWNER S MANUAL ONSITE WASTEWATER TREATMENT SYSTEM MODEL NUMBER FTB 0.5 FTB 0.6 FTB 0.75 FTB 1.0 FTB 1.5

OWNER S MANUAL ONSITE WASTEWATER TREATMENT SYSTEM MODEL NUMBER FTB 0.5 FTB 0.6 FTB 0.75 FTB 1.0 FTB 1.5 OWNER S MANUAL ONSITE WASTEWATER TREATMENT SYSTEM MODEL NUMBER FTB 0.5 FTB 0.6 FTB 0.75 FTB 1.0 FTB 1.5 1501 Commerce Center Drive Franklin OH 45005 Tel: 513-746-2727 Fax: 513-746-1446 www.consolidatedtreatment.com

More information

RP10 & GTS10 Systems 2. Septic Tanks & Grease Traps 4. OK1 Controllers, Pumps & Blowers 6. Recommended Service Spare Parts 7-8

RP10 & GTS10 Systems 2. Septic Tanks & Grease Traps 4. OK1 Controllers, Pumps & Blowers 6. Recommended Service Spare Parts 7-8 PRODUCT LIST Page 1 of 8 CONTENTS: PAGE: RP10 & GTS10 Systems 2 Irrigation Kits 3 Septic Tanks & Grease Traps 4 Pump Stations & Pump Station Controllers 5 OK1 Controllers, Pumps & Blowers 6 Recommended

More information

Modular Grease Trap MGTA

Modular Grease Trap MGTA Modular Grease Trap MGTA and MGTA) Installation Requirements Installation Water Requirements Corporation Water Corporation 22 Ethel Ave Brookvale NSW 2100 Postal: PO Box 255 Collaroy NSW 2097 Freecall

More information

SludgeHammer. Owner s Manual. Model S-400/600. The latest advance in wastewater treatment. NSF/ANSI Standard #40. nature called. we answered.

SludgeHammer. Owner s Manual. Model S-400/600. The latest advance in wastewater treatment. NSF/ANSI Standard #40. nature called. we answered. SludgeHammer nature called. we answered. commercial & industrial communities marine residential 1.800.426.3349 Model S-400/600 NSF/ANSI Standard #40 The latest advance in wastewater treatment Owner s Manual

More information

COMMERCIAL STRENGTH POLYMER MEDIA FILTER OWNERS MANUAL

COMMERCIAL STRENGTH POLYMER MEDIA FILTER OWNERS MANUAL COMMERCIAL STRENGTH POLYMER MEDIA FILTER OWNERS MANUAL INTRODUCTION Congratulations on choosing the Poolrite S6000 mk2, S5000 mk2, S8000 mk1 or S9000 mk4 High Rate Media Filter fitted with the exclusive

More information

ADDITIONAL INFORMATION FOR RETAIL FOOD PREMISES

ADDITIONAL INFORMATION FOR RETAIL FOOD PREMISES ADDITIONAL INFORMATION FOR RETAIL FOOD PREMISES INTRODUCTION Wastes like cooking oil, grease and food solids are produced by food outlets and services throughout the Timaru District every day. When this

More information

Biolytix BioPod Wastewater Treatment System. Owner s Manual. December Important

Biolytix BioPod Wastewater Treatment System. Owner s Manual. December Important Biolytix BioPod Wastewater Treatment System Owner s Manual December 2010 Important Your Biolytix BioPod must be maintained and repaired by a Biolytix-accredited technician. If an alarm sounds, follow the

More information

The Pressure Sewer System Owners Guide

The Pressure Sewer System Owners Guide The Pressure Sewer System Owners Guide Environment One Corporation A Precision Castparts Company The Pressure Sewer System * Your grinder pump station may be different than model shown. A pressure sewer

More information

HAMWORTHY- Sewage Treatment Unit

HAMWORTHY- Sewage Treatment Unit Brief Function, Operation & Maintenance Instruction for HAMWORTHY- Sewage Treatment Unit Content: 1. General Function 2. Operation 3. Maintenance 4. Service Buchheisterstraße 6 20457 Hamburg Germany Phone:

More information

Owners Manual for the Rainmaster Water Recycling System

Owners Manual for the Rainmaster Water Recycling System Owners Manual for the Rainmaster Water Recycling System 22874 Manual.indd 1 4/8/05 8:45:05 AM Rain Master Water Recycling System Welcome! Thank you for purchasing a Rainmaster Water Recycling System. Your

More information

RHK52_IB_FA_ Part No. T HERITAGE VOGUE KETTLE 2 YEAR WARRANTY RHK52 SERIES

RHK52_IB_FA_ Part No. T HERITAGE VOGUE KETTLE 2 YEAR WARRANTY RHK52 SERIES RHK52_IB_FA_261115 Part No. T22-5002822 HERITAGE VOGUE KETTLE 2 YEAR WARRANTY RHK52 SERIES INSTRUCTIONS 1 & WARRANTY IMPORTANT SAFEGUARDS When using electrical appliances, basic safety precautions should

More information

YORK KETTLE INSTRUCTIONS & WARRANTY 2 YEAR WARRANTY 20431AU 20431AU_IB_FA_190314

YORK KETTLE INSTRUCTIONS & WARRANTY 2 YEAR WARRANTY 20431AU 20431AU_IB_FA_190314 20431AU_IB_FA_190314 YORK KETTLE 2 YEAR WARRANTY 20431AU INSTRUCTIONS & WARRANTY W0911 Spectrum Brands Australia Pty Ltd Locked Bag 3004 Braeside Victoria 3195 Australia Customer Service in Australia Toll

More information

Note: Verify that plastic bags are removed from filters, if equipped or installed, before first use (see page 8) CONTENTS

Note: Verify that plastic bags are removed from filters, if equipped or installed, before first use (see page 8) CONTENTS DEAR CUSTOMER Thank you for purchasing the Ionmax Breeze ION420 Air Purifier. The Ionmax Breeze can help to improve the indoor air quality in your home or office. Please read this manual carefully before

More information

Table of Contents. Features Quality Policy Section A - Unit Operation Section B Unit Maintenance Trouble Shooting Guide...

Table of Contents. Features Quality Policy Section A - Unit Operation Section B Unit Maintenance Trouble Shooting Guide... Table of Contents Features... 3 Quality Policy... 3 Section A - Unit Operation... 4 Section B Unit Maintenance... 6 Trouble Shooting Guide... 7 Wiring Diagram... 9 Section C Unit Installation... 9 Unit

More information

Home owner s manual Pressure sewerage system

Home owner s manual Pressure sewerage system Home owner s manual Pressure sewerage system Table of contents 1 Introduction 4 2 Emergency contact numbers 4 3 What to do if the alarm sounds 4 4 The parts of the pressure sewerage system 7 4.1 Property

More information

YEAR 2WARRANTY. Windsor Kettle MODEL RHK3 INSTRUCTIONS & WARRANTY RHK3_IB3_281011

YEAR 2WARRANTY. Windsor Kettle MODEL RHK3 INSTRUCTIONS & WARRANTY RHK3_IB3_281011 2WARRANTY YEAR Windsor Kettle MODEL RHK3 INSTRUCTIONS & WARRANTY RHK3_IB3_281011 Spectrum Brands Australia Pty Ltd Locked Bag 3004 Braeside Victoria 3195 Australia Customer Service in Australia TollFree:

More information

HOME OWNERS MANUAL. Taylex Advanced Blower System (ABS)

HOME OWNERS MANUAL. Taylex Advanced Blower System (ABS) HOME OWNERS MANUAL Taylex Advanced Blower System (ABS) An Advanced Secondary Home Sewage Treatment Plant (HSTP) Aerated Wastewater Treatment System (AWTS) or Aerated Treatment Unit (ATU) Taylex ABS Home

More information

Managing your waste. To help businesses get rid of fats, oils, greases and leftover food correctly. Bin it don t block it.

Managing your waste. To help businesses get rid of fats, oils, greases and leftover food correctly. Bin it don t block it. Managing your waste. To help businesses get rid of fats, oils, greases and leftover food correctly. Bin it don t block it. What s the problem? If fats, oils, greases and leftover food go down your drains,

More information

Operation & Maintenance Manual inc. User Guide

Operation & Maintenance Manual inc. User Guide Operation & Maintenance Manual inc. User Guide Diamond Sewage Treatment DMS and DMC Consent holders and/or treatment plant users are responsible for correctly operating and maintaining their plant as per

More information

Town of Sturbridge Grinder Pump Policy Homeowner s Guide to Grinder Pumps

Town of Sturbridge Grinder Pump Policy Homeowner s Guide to Grinder Pumps Why do I have a grinder pump? Town of Sturbridge Grinder Pump Policy Homeowner s Guide to Grinder Pumps The low pressure sewerage system servicing your home is part of a larger Town of Sturbridge Wastewater

More information

Please read this manual carefully before use to ensure proper usage and save

Please read this manual carefully before use to ensure proper usage and save DEAR CUSTOMER Please read this manual carefully before use to ensure proper usage and save The package includes: User Manual Note: CONTENTS SAFETY INSTRUCTIONS 1 PRODUCT DIAGRAM 2 SPECIFICATIONS 2 PURIFICATION

More information

12L DEHUMIDIFIER OPERATING INSTRUCTIONS

12L DEHUMIDIFIER OPERATING INSTRUCTIONS 12L DEHUMIDIFIER OPERATING INSTRUCTIONS Attention: This Dehumidifier is rated to extract 12L per day in an environment of 80% humidity and temperature of 30 C. This is the world-wide standard for rating

More information

PRESSURE SEWER SYSTEMS GUIDE FOR HOME OWNERS AND BUILDERS

PRESSURE SEWER SYSTEMS GUIDE FOR HOME OWNERS AND BUILDERS PRESSURE SEWER SYSTEMS GUIDE FOR HOME OWNERS AND BUILDERS VERSION: 1.0 VERSION: 1.0 Pressure Sewer Hydraulic Design Guidelines 1 Version: 1.0 Page 1 of 15 Contents 1 Introduction... 4 Pressure Sewer System

More information

RHK112_IB_FA_ Part No. T INSPIRE KETTLE 2 YEAR WARRANTY RHK112 SERIES

RHK112_IB_FA_ Part No. T INSPIRE KETTLE 2 YEAR WARRANTY RHK112 SERIES RHK112_IB_FA_150518 Part No. T22-9000811 INSPIRE KETTLE 2 YEAR WARRANTY RHK112 SERIES INSTRUCTIONS 1 & WARRANTY IMPORTANT SAFEGUARDS When using electrical appliances, basic safety precautions should always

More information

Renwick Neighborhood Association Inc., Springhouse Ridge Zone 1205 N. Walnut Street Bloomington, IN

Renwick Neighborhood Association Inc., Springhouse Ridge Zone 1205 N. Walnut Street Bloomington, IN Renwick Neighborhood Association Inc., Springhouse Ridge Zone 1205 N. Walnut Street Bloomington, IN 47404 812.334.8819 Dear Homeowners, Your home is equipped with a grinder pump that handles the waste

More information

INSTRUCTION MANUAL MNBX14

INSTRUCTION MANUAL MNBX14 INSTRUCTION MANUAL MNBX14 Safety information Important - Please read these instructions fully before installing or operating Power source The appliance can be connected to a 220-240 volt 50Hz AC supply

More information

Operation & Maintenance Including User Guide

Operation & Maintenance Including User Guide Operation & Maintenance Including User Guide Diamond Sewage Treatment DMS and DMS-IPC DMC Please note - WPL Offers clear instructions on using and maintaining its treatment plants. Consent holders and/or

More information

Table of Contents. Forward Quality Policy Design Parameters Section A Unit Operation Section B Unit Maintenance...

Table of Contents. Forward Quality Policy Design Parameters Section A Unit Operation Section B Unit Maintenance... Table of Contents Forward... 3 Quality Policy... 3 Design Parameters... 4 Section A Unit Operation... 5 Section B Unit Maintenance... 6 Trouble Shooting Guide... 6 Wiring Diagram... 7 Section C Unit Installation...

More information

Biological Drain Maintenance System

Biological Drain Maintenance System Biological Drain Maintenance System A unique, automatic drain dosing system specifically designed to address the drainage problems found in commercial kitchens. Preventing the build-up of Fats, Oils and

More information

60cm Built-In Ceramic Cooktop

60cm Built-In Ceramic Cooktop 20130304 issue 8 啊哈 60cm Built-In Ceramic Cooktop Installation and User manual Content Safety instructions-----------------------------------2 Features of your product---------------------------4 Installing

More information

all-rounder Mini Compact Bagless Vacuum Cleaner Cyclonic Bagless Technology Washable HEPA Filtration Compact, Lightweight & Stylish Design all-rounder

all-rounder Mini Compact Bagless Vacuum Cleaner Cyclonic Bagless Technology Washable HEPA Filtration Compact, Lightweight & Stylish Design all-rounder all-rounder all-rounder Mini Compact Bagless Vacuum Cleaner Cyclonic Bagless Technology Washable HEPA Filtration Compact, Lightweight & Stylish Design 1 3 2 4 5 6 8 9 11 12 10 14 13 7 15 2. 5011 All-Rounder

More information

Web:

Web: P.O Box - 95466, United Arab Emirates Tel: +971 4 2637073, Mobile: +971 55 2191246, +971 52 864 1667 Email: info@sancouae.com, Web: It's about Peace of mind and a job done right, First time, Every time

More information

Portable Refrigerator

Portable Refrigerator Portable Refrigerator Owners Manual Single door 40 litre 65 litre 80 litre 125 litre Double door 74 litre 95 litre 2009 Introduction The National Luna range of portable fridges and freezers are high-performance,

More information

Trade Waste in the Food Industry

Trade Waste in the Food Industry Trade Waste in the Food Industry Trade Waste Bylaw 2008 Contents Introduction... 1 Why is there a need to control the effects of waste discharged from food premises?... 2 Food Premises are required to

More information

Table of Contents. Forward Quality Policy Design Parameters Section A Unit Operation Setting the Timer...

Table of Contents. Forward Quality Policy Design Parameters Section A Unit Operation Setting the Timer... Table of Contents Forward... 3 Quality Policy... 3 Design Parameters... 4 Section A Unit Operation... 5 Setting the Timer... 6 Typical Loading System... 8 Section B Unit Maintenance... 9 Trouble Shooting

More information

INSTRUCTION MANUAL / INSTALLATION MANUAL. 7kg Vented Dryer MODEL: KA7VENTDRYA

INSTRUCTION MANUAL / INSTALLATION MANUAL. 7kg Vented Dryer MODEL: KA7VENTDRYA INSTRUCTION MANUAL / INSTALLATION MANUAL 7kg Vented Dryer MODEL: KA7VENTDRYA THIS PAGE IS INTENTIONALLY LEFT BLANK 2 CONTENTS Safety Instructions 4 Your Kogan Vented Dryer 5 Before First Use 5 Accessory

More information

ECOJET GREASE LEVEL SENSOR

ECOJET GREASE LEVEL SENSOR ACO Passavant Installation guide ECOJET GREASE LEVEL SENSOR AUTHOR Kate Jennings DATE COMPLETED 8 August 2016 DATE COMPLETED V13 ACO Polycrete, 134-140 Old Bathurst Road, Emu Plains, NSW 2750 Tel: +61

More information

SEVILLE KETTLE INSTRUCTIONS & WARRANTY 2 YEAR WARRANTY 18152AU 18152AU_IB_FA_240712

SEVILLE KETTLE INSTRUCTIONS & WARRANTY 2 YEAR WARRANTY 18152AU 18152AU_IB_FA_240712 18152AU_IB_FA_240712 SEVILLE KETTLE 2 YEAR WARRANTY 18152AU INSTRUCTIONS & WARRANTY Spectrum Brands Australia Pty Ltd Locked Bag 3004 Braeside Victoria 3195 Australia Customer Service in Australia TollFree:

More information

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS User s Manual Inside you will find many helpful hints on how to use and maintain your dehumidifier properly. Just a little preventative care can save you money and prolong the life of your unit. INDEX

More information

Drying Cabinet With Timer

Drying Cabinet With Timer Malmet (Australia) Pty Ltd Head Office & Customer Service 9-11 McKay Avenue PO Box 373 LEETON NSW 2705 Phone: (02) 6953 7677 Email: inquiries@malmet-aus.com.au ABN 95 001 717 791 Operation, Maintenance

More information

General Care and Safety Guide

General Care and Safety Guide General Care and Safety Guide Thank you for choosing a Goldair Select Dehumidifier. This Goldair Select appliance has been designed and manufactured to high standards of engineering and with proper use

More information

OWNER S MANUAL FOR USE WITH BIO-MICROBICS, INC. FAST WASTEWATER TREATMENT SYSTEMS

OWNER S MANUAL FOR USE WITH BIO-MICROBICS, INC. FAST WASTEWATER TREATMENT SYSTEMS OWNER S MANUAL FOR USE WITH BIO-MICROBICS, INC. FAST WASTEWATER TREATMENT SYSTEMS IMPORTANT: We urge you to fully read this manual. The contents are important to your safety and the operation of the Bio-Microbics,

More information

ECOFLO V3 POOL & SPA PUMP

ECOFLO V3 POOL & SPA PUMP ECOFLO V3 POOL & SPA PUMP INSTALLATION AND OPERATION MANUAL Reltech Australia Pty Ltd 43-45 Kylta Rd West Heidelberg Vic 3081 Ph: (03) 9459 3838 Fax: (03) 9459 4038 www.reltech.com.au Page 1 of 11 Read

More information

OWNER S MANUAL. Convair Tower Heater CTH09. (English) (CTH09)

OWNER S MANUAL. Convair Tower Heater CTH09. (English) (CTH09) OWNER S MANUAL Convair Tower Heater CTH09 (English) (CTH09) SAFETY General Safety Please read these instructions before using the heater and keep for future reference. This appliance is not intended for

More information

20L Electronic Dehumidifier

20L Electronic Dehumidifier Operating Instructions 20L Electronic Dehumidifier Attention: This Dehumidifier is rated to extract 20L per day in an environment of 80% humidity and temperature of 30 C. This is the world-wide standard

More information

Instruction Booklet Please read these instructions carefully and retain for future reference

Instruction Booklet Please read these instructions carefully and retain for future reference G L A S S K E T T L E Instruction Booklet Please read these instructions carefully and retain for future reference KE9400 Contents Sunbeam s Safety Precautions 1 Features of your Sunbeam Kettle 2 Using

More information

M1C. Operator Manual

M1C. Operator Manual M1C Operator Manual !!!! WARNING Before installation and commisioning, you must read the safety instructions and warnings carefully and all the warning labels attached to the equipment. IMPORTANT Failure

More information

KESSEL Grease Separator Euro G NG 1, 2 and 4 For underground installation

KESSEL Grease Separator Euro G NG 1, 2 and 4 For underground installation INSTALLATION AND OPERATING INSTRUCTIONS KESSEL Grease Separator Euro G NG 1, 2 and 4 For underground installation KESSEL Grease Separator G according to EN 1825-1 NG 1,2, 4 - for underground installation

More information

Thank you for purchasing the Ionmax Serene ION138 Ultrasonic Aroma Diffuser. The Ionmax Serene reintroduces moisture into the air to help you

Thank you for purchasing the Ionmax Serene ION138 Ultrasonic Aroma Diffuser. The Ionmax Serene reintroduces moisture into the air to help you DEAR CUSTOMER Thank you for purchasing the Ionmax Serene ION138 Ultrasonic Aroma Diffuser. The Ionmax Serene reintroduces moisture into the air to help you maintain a comfortable humidity level in your

More information

PoolSweepa Wallclima / Optima Pool Cleaners. Operating Instructions

PoolSweepa Wallclima / Optima Pool Cleaners. Operating Instructions PoolSweepa Wallclima / Optima Pool Cleaners Operating Instructions 8151634 PoolSweepa Wallclima / Optima Pool Cleaners Operating Instructions Contents 1. INTRODUCTION... 2 2. SPECIFICATIONS... 2 3. WARNINGS

More information

Electric Aerator Installation Manual EL2

Electric Aerator Installation Manual EL2 Saving the planet s water nature s way Electric Aerator Installation Manual EL2 Koenders Windmills A Division of Koenders Water Solutions Inc. 3426 Saskatchewan Drive Regina, Saskatchewan Canada S4T 1H1

More information

VADA - Rain2Main Automatic Rainwater Controller

VADA - Rain2Main Automatic Rainwater Controller PRODUCT OVERVIEW / APPLICATION The Vada Rain2Main is designed to select between stored rainwater (when available) and mains supply water, and send this water to your toilet cistern, washing machine, garden

More information

8L DEHUMIDIFIER OPERATING INSTRUCTIONS

8L DEHUMIDIFIER OPERATING INSTRUCTIONS 8L DEHUMIDIFIER OPERATING INSTRUCTIONS Attention: This Dehumidifier is rated to extract 8L per day in an environment of 80% humidity and temperature of 30 C. This is the world-wide standard for rating

More information

BRITA. Water Filter & Chiller II. Chilled water filter. Instruction Booklet WF6100

BRITA. Water Filter & Chiller II. Chilled water filter. Instruction Booklet WF6100 BRITA Chilled water filter Instruction Booklet WF6100 Water Filter & Chiller II Please read these instructions carefully and retain for future reference. Contents Sunbeam s Safety Precautions 1 Features

More information

Operating Instructions

Operating Instructions Operating Instructions 10L Dehumidifier Attention: This Dehumidifier is rated to extract 10L per day in an environment of 80% humidity and temperature of 30 C. This is the world-wide standard for rating

More information

User Guide. For THE SWIMSUIT DRYER. Swimsuit Dryer manual Final. Copyright 2014 Page of 20

User Guide. For THE SWIMSUIT DRYER. Swimsuit Dryer manual Final. Copyright 2014 Page of 20 User Guide For THE SWIMSUIT DRYER. Swimsuit Dryer manual Final Copyright 2014 Page of 20 1 Table of Contents 1 LOCATION & INFORMATION DIAGRAMS... 4 2 PURPOSE... 6 2.1 PROPER USAGE AND LIABILITY... 6 2.2

More information

PRO-230 PRO-350 PRO-400 PRO-500 PRO-500DS ECO-PRO

PRO-230 PRO-350 PRO-400 PRO-500 PRO-500DS ECO-PRO GERMAN ENGINEERED PUMPS SINCE 1909 PRO SERIES PUMPS INSTALLATION AND OPERATION MANUAL PRO-230 PRO-350 PRO-400 PRO-500 PRO-500DS ECO-PRO 1 PRO SERIES PUMPS INSTALLATION AND OPERATION MANUAL PRO-230 PRO-350

More information

INSTRUCTION MANUAL BRAC SYSTEMS WARNING!!!

INSTRUCTION MANUAL BRAC SYSTEMS WARNING!!! INSTRUCTION MANUAL BRAC SYSTEMS Model W-125 Model W-200 Model W-325 WARNING!!! Water that has been recycled through the BRAC SYSTEM is not intended for drinking purposes! For this reason, do not install

More information

Operation & Installation Manual

Operation & Installation Manual Operation & Installation Manual Rinnai Instantaneous Water Heater Model - IHF10 This appliance shall be installed in accordance with: Manufacturer s Installation Instructions Current AS/NZS 3500 & AS/NZS

More information

Domino VGS-F.O.G. Domino VGS - F.O.G* Fat, Oil & Grease Separator. Separated Fat, Oil & Grease. Inlet Elbow Sludge Outlet

Domino VGS-F.O.G. Domino VGS - F.O.G* Fat, Oil & Grease Separator. Separated Fat, Oil & Grease. Inlet Elbow Sludge Outlet Domino VGS - F.O.G* Fat, Oil & Grease Separator Separated Fat, Oil & Grease Greasy Water In Cleaned Water Outlet Fat, Oil & Grease Out. Inlet Elbow Sludge Outlet Introduction Retail Food Businesses generate

More information

Fat-Free Sewers. How to Prevent Fats, Oils, and Greases from Damaging Your Home and the Enviroment

Fat-Free Sewers. How to Prevent Fats, Oils, and Greases from Damaging Your Home and the Enviroment Fats, Oils, and Greases aren t just bad for arteries and waistlines; they re bad for sewers too. - - - - - - - - - - - - - - - - - Sewer overflows and backups can cause health hazards, damage home interiors,

More information

HIGH PERFORMANCE POOL & SPA PUMPS

HIGH PERFORMANCE POOL & SPA PUMPS HIGH PERFORMANCE POOL & SPA PUMPS INSTALLATION AND OPERATION MANUAL PREMIUM PR SERIES PR50F, PR75F, PR100F, PR125F, PR150F, PR200F Reltech Australia Pty Ltd 43-45 Kylta Rd West Heidelberg Vic 3081 Ph:

More information

APP Environmental Services P/L.

APP Environmental Services P/L. APP Environmental Services P/L. 20 LITTLE BOUNDARY ROAD LAVERTON NORTH. VIC. 3026. PO BOX 519, ALTONA NORTH. VIC. 3025. PHONE: 03 9362 4614 FAX: (03) 9362 4603 Mobile: 0418 547653 Email: david@appenviro.com.au

More information

aquamanta the experts in aquatic technology CH 025/050/100/ 150/200/300 NEW PHOTO Instruction Manual

aquamanta the experts in aquatic technology CH 025/050/100/ 150/200/300 NEW PHOTO Instruction Manual aquamanta TM the experts in aquatic technology CH 025/050/100/ 150/200/300 NEW PHOTO Instruction Manual Technical Information Model Wattage Aquarium Volume CH 025 CH 050 CH 100 CH 150 CH 200 CH 300 25W

More information

WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C, 140 AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS

WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C, 140 AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS 6 th June 2006 Page 1 WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C, 140 AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS Please read and follow all these instructions carefully before proceeding

More information

TENANT HANDBOOK. Helpful tips, advice for emergencies.

TENANT HANDBOOK. Helpful tips, advice for emergencies. TENANT HANDBOOK Helpful tips, advice for emergencies LOOKING AFTER YOUR HOME You are responsible for keeping your home in good condition. To help you do this it is best to carry out small tasks and checks

More information

O Pro electric storage water heater

O Pro electric storage water heater O Pro electric storage water heater PREMIUM SERIES MAINS PRESSURE ELECTRIC STORAGE WATER HEATERS DOCUMENTATION FOR INSTALLATION AND OPERATION New Zealand INDOOR INSTALLATION ONLY MODEL 272014 MODEL 282029

More information

ELECTRIC RADIANT OUTDOOR / INDOOR HEATER

ELECTRIC RADIANT OUTDOOR / INDOOR HEATER ELECTRIC RADIANT OUTDOOR / INDOOR HEATER INSTALLATION, OPERATION & MAINTENANCE MANUAL IMPORTANT INSTRUCTIONS SAVE THESE INSTRUCTIONS Prior to installing and operating the heater, read these instructions

More information

Owners Manual Model: XXL

Owners Manual Model: XXL Corporate Office 200, 11246-163 St. Edmonton AB T5M 1Y6 Phone: 780-930-1100 Fax: 780-930-1125 Toll Free: 1-877-528-2010 www.zephyrairsystems.com AIR PURIFIER E356005 Owners Manual Model: XXL Maintenance

More information

Electronically controlled instantaneous water heater. MCX: 27300, and models. Instructions for the user

Electronically controlled instantaneous water heater. MCX: 27300, and models. Instructions for the user Electronically controlled instantaneous water heater MCX: 27300, 27400 and 27600 models Instructions for the user These appliances deliver water not exceeding 50 ºC in accordance with AS3498. 1. Overview

More information

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS IMPORTANT: READ AND SAVE THESE INSTRUCTIONS FOR THE BENEFIT OF THE USER

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS IMPORTANT: READ AND SAVE THESE INSTRUCTIONS FOR THE BENEFIT OF THE USER THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS IMPORTANT: READ AND SAVE THESE INSTRUCTIONS FOR THE BENEFIT OF THE USER Thank you for choosing a quality Redring product manufactured by

More information

Belle-Aqua. 1 litre stainless steel kettle. Instruction Booklet KE7110. Please read these instructions carefully and retain for future reference.

Belle-Aqua. 1 litre stainless steel kettle. Instruction Booklet KE7110. Please read these instructions carefully and retain for future reference. Belle-Aqua 1 litre stainless steel kettle Instruction Booklet KE7110 Please read these instructions carefully and retain for future reference. Contents Sunbeam s Safety Precautions 1 Features of your Sunbeam

More information

INSTALLATION AND INSTRUCTION MANUAL IMPORTANT PLEASE READ:

INSTALLATION AND INSTRUCTION MANUAL IMPORTANT PLEASE READ: EAZYPODAUTO1140318MAN UK English INSTALLATION AND INSTRUCTION MANUAL IMPORTANT PLEASE READ: When you first start up the EazyPod Automatic, the cleaning cycle will start first. You will need to wait up

More information

DIGIHEAT IN LINE HEATERS

DIGIHEAT IN LINE HEATERS DIGIHEAT IN LINE HEATERS Installation and operation manual for Single & Three Phase Models Offices - Australia NSW - Sydney (Head Office) Tel: +61 2 9898 8600 QLD - Brisbane Tel: +61 7 3299 9900 VIC/TAS

More information

INSTALLATION INSTRUCTIONS OWNERS GUIDE & WARRANTY STATEMENT

INSTALLATION INSTRUCTIONS OWNERS GUIDE & WARRANTY STATEMENT 315050B APR 2018 INSTALLATION INSTRUCTIONS OWNERS GUIDE & WARRANTY STATEMENT RHEEM ELECTRIC DAIRY HOT WATER HEATER Congratulations for choosing a Rheem Water Heater It is important that you take a few

More information

ALL IN ONE SERIES HOTLINE 1300 AQUATEC INSTRUCTION MANUAL MODEL 03AS310 03AS311. DATE JULY 2017 v2.0. AQP All in One 1000 Instructions.

ALL IN ONE SERIES HOTLINE 1300 AQUATEC INSTRUCTION MANUAL MODEL 03AS310 03AS311. DATE JULY 2017 v2.0. AQP All in One 1000 Instructions. INSTRUCTION MANUAL DATE JULY 2017 v2.0 HOTLINE 1300 AQUATEC MODEL 03AS310 03AS311 AQP All in One 1000 Instructions.indd 1 CONGRATULATIONS ON YOUR PURCHASE OF THIS PRODUCT BY AQUAPRO, THE ANSWERS FOR YOUR

More information

USER MANUAL PLEASE READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE USE.

USER MANUAL PLEASE READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE USE. 65L Dual Zone Fridge USER MANUAL PLEASE READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE USE. SAFETY INSTRUCTIONS Please read the user manual and safety instructions carefully before using the appliance.

More information

Mobile Air Conditioner Instruction Manual Model TC-N9KM

Mobile Air Conditioner Instruction Manual Model TC-N9KM Mobile Air Conditioner Instruction Manual Model TC-N9KM Please read and retain these instructions for future reference SPECIFICATION Model no. Cooling capacity Power/Ampere consumption for cooling* Air

More information

Owner s Manual. Installation Details Owner s Information. 80L to 400L Electric Storage Water Heaters

Owner s Manual. Installation Details Owner s Information. 80L to 400L Electric Storage Water Heaters Models: RIN80E24 RIN80E36 RIN125E24 RIN125E36 RIN160E24 RIN160E36 RIN250E36 RIN315E36 RIN400E36 Installation Details Owner s Information For advice, repairs and service, call: 1300 555 545 Carefully remove

More information

Installation, Operation, and Maintenance Manual. ASP HDPE Package Sewage Treatment Plants

Installation, Operation, and Maintenance Manual. ASP HDPE Package Sewage Treatment Plants 136249 Installation, Operation, and Maintenance Manual for ASP HDPE Package Sewage Treatment Plants Standard Discharge Level: 20BOD/30SS/20NH3-N Premier Tech Aqua Ltd 2 W hitehouse Way So uth West Industrial

More information

INSTRUCTIONS AND WARRANTY

INSTRUCTIONS AND WARRANTY INSTRUCTIONS AND WARRANTY MODEL NO. RHHD22 RUSSELL HOBBS HAIR DRYER Congratulations on purchasing our Russell Hobbs Hair dryer. Each unit is manufactured to ensure safety and reliability. Before using

More information

Owner s Manual AMERICAN PERC-RITE. WASTEWATER DRIP SYSTEMS 2 ZONE or 4 ZONE SIMPLEX or DUPLEX

Owner s Manual AMERICAN PERC-RITE. WASTEWATER DRIP SYSTEMS 2 ZONE or 4 ZONE SIMPLEX or DUPLEX Owner s Manual AMERICAN PERC-RITE WASTEWATER DRIP SYSTEMS 2 ZONE or 4 ZONE SIMPLEX or DUPLEX PATENT # s: 5,200,065 ; 5,984,574B ; 6,261,452B1 OWNER S NAME NAME STREET NAME CITY, STATE ZIP LOCATION HEALTH

More information

PRIMUS IMPORTANT. User Manual and Product Specifications. Portable Fridge/Freezer. Part No. PRI18LP - 18 Litre. Read instructions before operation.

PRIMUS IMPORTANT. User Manual and Product Specifications. Portable Fridge/Freezer. Part No. PRI18LP - 18 Litre. Read instructions before operation. PRIMUS Portable Fridge/Freezer User Manual and Product Specifications Part No. PRI18LP - 18 Litre IMPORTANT Read instructions before operation. Getting to know your Portable Fridge/Freezer IDENTIFICATION

More information

Instruction Manual. By Evakool. Please read these instructions and the Safety section carefully before using your refrigerator.

Instruction Manual. By Evakool. Please read these instructions and the Safety section carefully before using your refrigerator. Nexberg Pty Ltd T/a Evakool 16 Enterprise St CALOUNDRA QLD 4551 Tel : 07 5492 7777 Fax : 07 5492 7733 Please read these instructions and the Safety section carefully before using your refrigerator. 1.Safety

More information

Warning: 230V / 1ph / 50Hz V / 3ph / 50Hz. Remarks: Make sure that you have enough power. (See page 15 Cable table)

Warning: 230V / 1ph / 50Hz V / 3ph / 50Hz. Remarks: Make sure that you have enough power. (See page 15 Cable table) 1 2 Warning: - Do not place your hand or any other objects into the air outlet and fan. It could damage the heat pump and cause injuries; - In case of any abnormality with the heat pump, cut off the power

More information

Mira Vision Wireless Controller

Mira Vision Wireless Controller Mira Vision Wireless Controller These instructions must be left with the user User Guide 1 128684-A2-A CONTENTS Introduction...3 Safety Information...3 Control Layout...4 Display Symbols...5 Using the

More information

RHPK3000_IB_FA_ SALT & PEPPER MILLS 2 YEAR WARRANTY RHPK3000

RHPK3000_IB_FA_ SALT & PEPPER MILLS 2 YEAR WARRANTY RHPK3000 RHPK3000_IB_FA_160115 SALT & PEPPER MILLS 2 YEAR WARRANTY RHPK3000 INSTRUCTIONS 1 & WARRANTY Congratulations on the purchase of your Russell Hobbs appliance. Each unit is manufactured to ensure safety

More information

SUMMER. Over the summer, there are a number of indoor. Inspecting your home on a regular basis and. Seasonal Maintenance Schedule. For A Healthy Home

SUMMER. Over the summer, there are a number of indoor. Inspecting your home on a regular basis and. Seasonal Maintenance Schedule. For A Healthy Home Seasonal Maintenance Schedule For A Healthy Home SUMMER Over the summer, there are a number of indoor and outdoor maintenance tasks to complete including repairing walkways and steps, painting and checking

More information

MariGlo LED. Inspiring Excellence in Fish Keeping! 45 / 60 / 90 / 120.

MariGlo LED. Inspiring Excellence in Fish Keeping! 45 / 60 / 90 / 120. MariGlo LED 45 / 60 / 90 / 120 Inspiring Excellence in Fish Keeping! Instruction version: 01/10/2013 Important Safeguards To guard against injury, basic safety precautions should be observed, including

More information

USE & CARE MANUAL PRO-TOUCH PLEASE READ PRIOR TO USE SENSOR 2 YEAR WARRANTY D6050AU

USE & CARE MANUAL PRO-TOUCH PLEASE READ PRIOR TO USE SENSOR 2 YEAR WARRANTY D6050AU USE & CARE MANUAL PLEASE READ PRIOR TO USE PRO-TOUCH SENSOR 2 YEAR WARRANTY D6050AU 1 IMPORTANT SAFEGUARDS Warning: Do not use this appliance near bath tubs, showers, basins or other vessels containing

More information

OWNER S MANUAL. CoolTower CTF07. (English) (CTF07)

OWNER S MANUAL. CoolTower CTF07. (English) (CTF07) OWNER S MANUAL CoolTower CTF07 (English) (CTF07) SAFETY General Safety Please read these instructions before using the fan and keep for future reference. This appliance is not intended for use by persons

More information

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS INSTALLATION AND OPERATING INSTRUCTIONS KESSEL Grease Separator G, D and D+S versions Certified under Euro-Norm EN 1825-1 For free standing installation in frost free areas KESSEL Grease separators G,

More information

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS WARNING TO PREVENT FIRE OR SHOCK HAZARD, DO NOT USE THIS PLUG WITH AN EXTENSION CORD, RECEPTACLE OR OTHER OUTLET UNLESS THE BLADES CAN BE FULLY INSERTED TO PREVENT BLADE EXPOSURE. TO PREVENT FIRE OR SHOCK

More information

Instruction Manual. Please read these instructions and the Safety section carefully before using your refrigerator.

Instruction Manual. Please read these instructions and the Safety section carefully before using your refrigerator. Nexberg Pty Ltd T/a Evakool 16 Enterprise St CALOUNDRA QLD 4551 Tel : 07 5492 7777 Fax : 07 5492 7733 Please read these instructions and the Safety section carefully before using your refrigerator. 1.Safety

More information