LED Protected Catalogue

Size: px
Start display at page:

Download "LED Protected Catalogue"

Transcription

1 LED Protected Catalogue Q3-18

2

3

4 Contents 06 Welcome 09 Vapour Proofs 12 Hazardous Zone 1 18 Hazardous Zone 2 21 Prison Luminaires 04 Province Lighting Contents LED Protected Catalogue

5 LED Protected Catalogue Province Lighting 05

6 Welcome 06 Light fittings for use in hazardous areas have the following characteristics; they are sealed to prevent the ingress of liquid, gas or dust and are constructed of a robust impact resistant materials. They have a seal or machined face to ensure resistance to liquid, dust or gas, or a quenching flame path. Light fittings have different grades of protection depending on their construction and intended purpose. Some fittings are classified according to their Ingress Protection (IP) rating as it is designated. Aspect of Hazardous Lighting In some contexts a hazardous area could be a badly lit step, however, we consider it an area in which a flammable material, gas or vapour must be mixed in the correct proportion with air and within this mixture a spark or heat is present, sufficient to ignite the mixture. When Light fittings and other electrical apparatus are to be installed in a Hazardous Area it is essential that the decision maker takes measures to reduce the likelihood of an explosion by the correct selection of the equipment to be installed in that area. As the gases and vapours liable to be present are rated according to ignition temperature, Flash point and lower explosive limit, this information must be on hand when making your light fitting selection. Gases also have a gas group classification, namely Group I, Group IIA, Group IIB and Group IIC, where Methane falls in the category Group I, while Hydrogen is a Group IIC gas, together with Acetylene. The general classification of the area is then Zone 1 and 2 for gases and vapours and volatile liquids present in the air Zone 21 for combustible dusts, metallic and non-metallic and also fibres in suspension in the air Zone 22 dust and easily combustible fibres, not normally in suspension in the air, but are present in sufficient quantities to produce a combustible mixture. Various types of lighting equipment is available locally for installation in the various hazardous locations, some are locally manufactured while others are imported, mainly from Europe. South Africa has a history of either United Kingdom or European technology. A common fault of the light fitting purchaser is the non-specification of the gland type required for the installation which has to be compatible to the type of cable and the core diameters. There are different glands available for steel armoured cable and for sheathed cables. Also cables should be of the flame retardant type if for exposed usage and if not sand covered. Of the more common type of light fittings available for the Zone 1 situation are those designated and enclosed in: i) Flameproof or explosion proof Ex d housings. ii) Increased Safety Ex e. Although both are suitable for use in this type of atmosphere there is a world of difference in their construction format. 06 Province Lighting Contents LED Protected Catalogue

7 Hazardous Area Classification Zone 0, Zone 1 and Zone 2 Locations GENERAL: Zone 0, Zone 1 and Zone 2 locations are those in which flammable gases or vapours are or may be present in the air in quantities sufficient to become hazardous. Zone 0 Locations These are locations in which flammable gases or vapours are continuously present in concentrations within the lower and upper limits of flammability. NOTE: Such a condition is rarely encountered and is limited mainly to confined spaces (such as the vapour space of closed process vessels, closed tanks and closed containers), although it may also occur in larger rooms, such as rooms in chemical plants. Even in such spaces it is possible that the gas-air or vapour-air mixture is normally outside the flammability range. Zone 1 Locations These are locations: a) in which hazardous concentrations of flammable gases or vapours occur intermittently or periodically under normal operating conditions, or b) in which hazardous concentrations of flammable gases or vapours may occur frequently because of repair or maintenance operations or leakage, or c) in which breakdown or faulty operation of equipment or processes, which release dangerous concentrations of flammable gases or vapours, might also cause simultaneous failure of electrical equipment. NOTE: this classification usually includes locations where volatile flammable liquids or liquefied flammable gases are transferred from one container to another; interiors of spray booths and areas in the vicinity of spraying and painting operations where volatile flammable solvents are used; locations containing open tanks or vats of volatile flammable liquids; drying rooms or compartments for the evaporation of flammable solvents; locations containing fat or oil-extraction apparatus using volatile flammable solvents; portions of cleaning and drying plants where flammable liquids are used; gas generator rooms; inadequately ventilated pump rooms for flammable gases or for volatile flammable liquids and all other locations where hazardous concentrations of flammable vapours or gases may occur in the course of normal operations. Zone 2 Locations These are locations in which operations concerned with flammable or explosive substances, gases, or vapours or volatile liquids are so well controlled that an explosive or ignitable concentration is only likely to occur under abnormal conditions. NOTE 1: The following shall be regarded as the minimum requirements for a location to which this classification is applicable: a) The area is so well ventilated that, if abnormal conditions arise, ignitable concentrations of the gas or vapour are rapidly dispersed and their possible contact with electrical equipment is of minimum duration. Zone 21 and Zone 22 Locations GENERAL: Zone 21 and 22 locations are those which are hazardous because of the presence of combustible dust and fibres. NOTE: Locations that house only plant and machinery that become non-operative if they lose their dust-tightness or if their internal pressure ceases to be below atmospheric pressure and locations where combustible dust is stored in dust tight containers only, need not be classified. The classification of locations where dust is not normally in suspension in the air, but where mechanical failure or abnormal operation of machinery or equipment might cause suspension of dust and might also provide a simultaneous source of ignition through failure of electrical equipment, operation of protective devices, etc., depends on the specific circumstances. Zone 21 Locations These are locations: a) in which, under normal operating conditions, combustible dust or fibre is (or is likely to be) in suspension in the air in quantities sufficient to produce an explosive or ignitable mixture, b) in which metallic dusts may be present. NOTE: This classification usually includes, for example, rooms containing machines (such as grinders, pulverisers, cleaners, graders and scrapers that are not provided with suitable dust extraction or exhaust systems, open bins and hoppers, terminal points of open conveyors and spouts in grain processing plants, starch plants, sugar plants, malting plants, hay plants and coal plants); and all working areas where metallic dusts and powders are produced, processed, handled, packed, or stored (except when these are stored in sealed containers). Zone 22 Locations These are locations in which combustible dust or fibre will not normally be in suspension in the air, or will not be likely to be thrown into suspension by the normal operation of equipment or apparatus, in quantities sufficient to produce an explosive or ignitable mixture, but where a) Deposits or accumulations of such dust may be enough to interfere with the safe dissipation of heat from electrical apparatus, or b) Deposits or accumulations of dust in, on, or in the vicinity of electrical apparatus might be ignited by arcs, sparks, or burning materials from such apparatus. Hazardous Classification LED Protected Catalogue Province Lighting 07

8 Selection of Equipment Selection of equipment for hazardous locations Before one considers the selection of the different types of protected equipment, we should first look at ways in which the dangers of a hazardous location can be reduced. Wherever possible, electrical equipment should be situated in a safe area, but only where this will lead to a reduction of the hazard. A good example is an electric motor situated in a Zone 1 or 2 location remotely controlled by a starter in a safe location. Explosion proof Explosion proof is used as a general term and relates to the various methods of protecting electrical apparatus for use in hazardous locations. Flameproof apparatus (Ex d) Flameproof or (Ex) d equipment is manufactured in such a way that it can withstand an internal ignition. Any gaps or flame path in the enclosure are designed in such a way as to dissipate sufficient energy so that by then time the energy from the ignition reaches the outside of the enclosure, there is not sufficient energy to ignite the surrounding flammable atmosphere. This means that the equipment needs to be heavy and hence expensive, comprising wide flanges on the mating machined surfaces and deeply threaded entries providing a labyrinth like flame-trap. Specially protected apparatus (Ex s) Ex s specially protected is designed and manufactured for special requirements and shall be accompanied by a test certificate issued by the SABS to prove it is safe. Intrinsically safe apparatus (Ex i) The principle of intrinsically safe equipment is that both the voltage and the current are limited by means of an electronic circuit so that even under fault conditions, neither the voltage nor the current could ever exceed parameters that would allow an arc or spark large enough to ignite the inflammable atmosphere. Pressurized apparatus (Ex p) This type of apparatus separates the inflammable atmosphere from arcs, sparks or hot surfaces by pressurizing or purging the enclosures with air or an inert gas. The pressure inside the apparatus is kept above the ambient pressure outside. Increased safety apparatus (Ex e) In this type of protected electrical equipment, special precautions have been taken to prevent sparking, arcing and the occurrence of temperatures high enough to ignite a prescribed gas- or vapour-to-air mixture. A typical type e piece of apparatus for use in a coal mine would have non-sparking cable terminal connections, be classified IP65 (dust tight) and be rated temperature class T1 (methane gas). Non-sparking apparatus (Ex n) This apparatus is normally used in Zone 2 locations where, in normal operation, it is not capable of igniting a surrounding explosive atmosphere and a fault capable of causing ignition is not likely to occur. As for increased safety type equipment, non-sparking apparatus is classified with IP and temperature class ratings. Dust-tight and dust ignition-proof apparatus (DIP) This type of apparatus should be rated at least to a degree of protection IP65. This type of apparatus may be certified for use in atmospheres containing metallic and non-metallic dusts, or non-metallic dusts only, i.e. equipment approved for non-metallic dusts may not be used in atmospheres contaminated with metallic dusts. 08 Province Lighting Selection of Equipment LED Protected Catalogue

9 Vapour Proofs 09 Vapour Proofs LED Protected Catalogue Province Lighting 09

10 Metropolis Vapour Proof Interchangeable SMD LED gear tray Includes stainless steel clips Chemical and impact resistance 80W Constant current driver Clear PC Diffuser with UV Protection Ordering example: Product Name/Length/CRI/Kelvin/Wattage (e.g. MetropolisVP/12/84/40/39) V CRI 84+ Surface or Suspended Mounted Luminaire Polycarbonate Housing Powder Coated Steel Plate - COB luminous flux: CODE Length CRI K W (system) Lm MetropolisVP/12/84/40/ mm K 39W 4600Lm MetropolisVP/15/84/40/ mm K 48W 5740Lm Alesta Vapour Proof Interchangeable SMD LED gear tray PC Diffuser with UV Protection Includes stainless steel clips Ordering example: Product Name/Length/Kelvin/Wattage (e.g. AlestaVP/6/41/12) V CRI 80+ Surface Mounted Luminaire UV Stabilised Polycarbonate Body & Frosted Lens - COB luminous flux: CODE Length CRI K W (system) Lm AlestaVP/6/41/12 632mm K 12W 1200Lm AlestaVP/12/41/ mm K 24W 2400Lm AlestaVP/15/41/ mm K 30W 3000Lm 10 Province Lighting Vapour Proofs LED Protected Catalogue

11 Saxa Triproof Efficacy of up to 100Lm/W Easy replacement and installation Minimum lumen maintenance: h Ordering example: Product Name/Length/CRI/Kelvin/Wattage (e.g. Saxa/6/83/40/18) V CRI 83+ Surface Mounted Aluminium Housing Shock & Pressure Proof Polycarbonate - CODE Length CRI K W (system) Lm Saxa/6/83/40/18 613mm K 18W 1800Lm Saxa/11/83/40/ mm K 36W 3600Lm Saxa/14/83/40/ mm K 54W 5400Lm KELVIN OPTIONS: 2700K 4000K 6500K 3000K 5000K Vapour Proofs LED Protected Catalogue Province Lighting 11

12 Hazardous Zone Province Lighting Hazard Zone 1 LED Protected Catalogue

13 Alexa Designed for Zones 1, 2, 21 and 22 hazardous areas Explosion Protection: II 2G Ex e ib mb op is IIC T5 Gb / II 2D Ex op is tb IIC T75 C Db Efficacy of up to 156Lm/W Minimum lumen maintenance: h (L100B10) Ordering example: Product Name/ Angle/Length/CRI/Kelvin/Wattage/Cable Configuration (e.g. Alexa/120/8/70/50/20/CFT) V CRI 70+ Surface Mounted Wall Mounted Suspended Mounting Co-extruded Polycarbonate Techfiller Diffuser 120 (Standard) 180 (Batwing) 60 (Highbay) MOUNTING ACCESSORIES: CODE Length CRI K W (system) Lm Alexa/8/70/50/18 800mm K 18.5W 2800Lm Alexa/12/70/50/ mm K 37.5W 5600Lm Alexa/17/70/50/ mm K 56W 8400Lm Kit Fix Fast Kit Fix Standard Kit Suspension DIMENSIONS: BEAM ANGLES: Highbay 60º Standard 120º Batwing 180º LIGHT DISTRIBUTION: Standard 120º Long-life s The outer tube is made of high-grade UV-protected polycarbonate to deliver more than 15 years of permanent operation in outdoor conditions. The endcaps are made of high-shock-resistance black polycarbonate, with bases glued onto the outer tube for sealed-for-life operation. The design of each component is executed in such a way that the system is expected to deliver a 20-year lifetime in normal conditions. This high reliability has been proven over several months of laboratory testing within a high-temperature enclosure to artificially accelerate the materials aging process; the built-in ambient temperature sensors makes it possible to enable autoprotective dimming and full temperature monitoring of each lamp. This prevents from early failures due to process heat influences as well as failures due to out of temperature range usage of the luminaires. ATEX cable gland 3- or 5- pole connector ATEX Wireless Control Module (WCM) PCB Lid made of glass-fibr e reinforced polyamide Lid screwed on the base Base glued on the housing Cable pass-through LEDs PCB mounted on aluminium smart cooling plat e Multi-extruded housing (diffuse/opaque) made of high efficient anti-uv polycarbonate Multi-extruded housing Driver Long-life driver mounted on aluminium passive cooling plat e For a complete technical brochure please contact your Province Lighting representative. Hazard Zone 1 LED Protected Catalogue Province Lighting 13

14 14 Province Lighting Hazard Zone 1 LED Protected Catalogue

15 Hida Explosion Proof Designed for Zones 1, 2, 21 and 22 hazardous areas Explosion Protection: Ex d IIC T5 Gb / Ex tb IIIB T100ºC Db Efficacy of up to 120Lm/W Minimum lumen maintenance: h (L70B10) Ordering example: Product Name/Medium or High /CRI/Kelvin/Wattage (e.g. Hida/MP/80/50/30) V CRI 80+ Pendant Ceiling Wall Pole Die-cast Aluminium Heat & Impact Resistant Tempered Glass 120 (Clear or diffused) CODE CRI K W (system) Lm (system) Hida/MP/80/50/ K 30W 3963Lm Hida/MP/80/50/ K 50W 5825Lm Hida/MP/80/50/ K 80W 9778Lm Hida/MP/80/50/ K 100W 11768Lm Hida/HP/80/50/ K 120W 12230Lm Hida/HP/80/50/ K 150W 14512Lm Hida/HP/80/50/ K 200W 19853Lm Hida/HP/80/50/ K 240W 22168Lm 6.5Kg Fitting 30W to 100W Medium (MP) 9.32Kg Fitting 120W to 240W High (HP) Lex 160 Designed for Zones 1, 2, 21 and 22 hazardous areas Explosion Protection: Ex d IIB T6 Gb / Ex tb IIIB T85 C Db Multi-protection constant current driver Minimum lumen maintenance: h (L70B10) Ordering example: Product Name/CRI/Kelvin/Wattage (e.g. Lex160/80/45/80) V CRI 80+ Pendant / Wall Mounting Flanges Aluminium Housing Tempered Glass with Stainless Steel Guard CODE CRI K W (system) Lm (system) Lex160/80/45/ K 80W 8800Lm Lex160/80/45/ K 100W 11000Lm Lex160/80/45/ K 120W 13200Lm Lex160/80/45/ K 160W 17600Lm Hazard Zone 1 LED Protected Catalogue Province Lighting 15

16 Lex 60 Designed for Zones 1, 2, 21 and 22 hazardous areas Explosion Protection: Ex d IIB T6 Gb / Ex tb IIIB T85 C Db Multi-protection constant current driver Minimum lumen maintenance: h (L70B10) Ordering example: Product Name/CRI/Kelvin/Wattage (e.g. Lex60/80/45/60) V CRI 80+ Pendant / Wall Mounting Flanges Aluminium Housing Tempered Glass with Stainless Steel Guard 120 CODE CRI K W (system) Lm (system) Lex60/80/45/ K 60W 6600Lm Blaz Explosion Proof Designed for Zones 1, 2, 21 and 22 hazardous areas Explosion Protection: Ex d IIC T6 Gc / Ex tc IIIC T85º Dc Efficacy of up to 120Lm/W Minimum lumen maintenance: h (L70B10) Ordering example: Product Name/CRI/Kelvin/Wattage (e.g. Blaz/80/50/21) V CRI 80+ Pendant Ceiling Wall Pole (30 ) Die-cast Aluminium Heat & Impact Resistant Tempered Glass 180 CODE CRI K W (system) Lm (system) Blaz/80/50/ K 21W 2693Lm Blaz/80/50/ K 30W 3516Lm Blaz/80/50/ K 44W 5177Lm 16 Province Lighting Hazard Zone 1 LED Protected Catalogue

17 Orthrus Emergency Designed for Zones 1, 2, 21 and 22 hazardous areas Explosion Protection: Ex d ib IIC T6 Gb / Ex tb IIIC T6 D Double LED lamps adjustable to 360º Heavy duty Ni-Mh battery supplies 90 minutes of illumination Ordering example: Product Name/CRI/Kelvin/Wattage (e.g. Orthrus/85/50/2x3) 220V CRI 85+ Pendant / Wall Mounting Flanges Aluminium Alloy Shock & Temperature Resistant Borosilicate Glass - CODE CRI K W (system) Lm (system) Orthrus/85/50/2x K* 2 x 3W 2 x 330Lm * Various kelvin options available to suit project requirements Hazard Zone 1 LED Protected Catalogue Province Lighting 17

18 Hazardous Zone Province Lighting Hazard Zone 2 LED Protected Catalogue

19 Chadd Designed for Zones 2, 21 and 22 hazardous areas Explosion Protection: Ex na IIC T4 Gc Efficacy of up to 92Lm/W Minimum lumen maintenance: h (L90B10) Ordering example: Product Name/CRI/Kelvin/Wattage (e.g. Chadd/80/40/64) V CRI 80+ Ceiling Wall Pole Chain Suspension GRP Fibreglass Body Injection Moulded Polycarbonate Lens with Internal Prism - CODE CRI K W (system) Lm (system) Chadd/80/40/ K 64W 5949Lm Aimon Designed for Zones 2 and 22 hazardous areas Explosion Protection: Ex Na IIC T6 Gc / Ex tc IIIC T85ºC Dc/Db Efficacy of up to 136Lm/W Minimum lumen maintenance: h (L70B10) Ordering example: Product Name/Length/CRI/Kelvin/Wattage (e.g. Aimon/6/80/50/38) V CRI 80+ Pendant Ceiling Wall Pole Die-cast Aluminium Heat & Impact Resistant Polycarbonate 120 (Clear or diffused) CODE Length CRI K W (system) Lm Aimon/6/80/50/38 600mm K 38W 5035Lm Aimon/12/80/50/ mm K 74W 10097Lm Hazard Zone 2 LED Protected Catalogue Province Lighting 19

20 Ilma Designed for Zones 2, 21 and 22 hazardous areas Glare free Efficacy of up to 92Lm/W Minimum lumen maintenance: h (L90B10) Ordering example: Product Name/Length/CRI/Kelvin/Wattage (e.g. Ilma/7/80/40/33) V CRI 80+ Pole Clamp Mounting Hook Suspension 304 Stainless Steel Housing Clear Tempered Glass - CODE Length CRI K W (system) Lm Ilma/7/80/40/33 790mm K 33W 2903Lm Ilma/13/80/40/ mm K 64W 5949Lm Alvaro Designed for Zones 2, 21 and 22 hazardous areas Explosion Protection: Ex na IIC T4 Gc Minimum lumen maintenance: h (L70B10) Ordering example: Product Name/Kelvin/Wattage (e.g. Alvaro/50/30) V - Ceiling Wall Pole Die-cast Aluminium Clear Armour Plate Glass - CODE CRI K W (system) Lm (system) Alvaro/50/ K 30W 2471Lm 20 Province Lighting Hazard Zone 2 LED Protected Catalogue

21 Prison Luminaires 21 Prison Luminaires LED Protected Catalogue Province Lighting 21

22 Ritza Suitable for use in prison cell subway, magistrate/police holding cells, railway stations and small factories Vandal resistant screws SABS certified complying with SABS/IEC Ordering example: Product Name/Night Light/Length/Wattage (e.g. Ritza/7/18) Module - T8 Lamps Surface Mounted Powder Coated 304 or 316 Stainless Steel Body JB Polycarbonate Diffuser - CODE Length W (system) Lamp Ritza/7/18 740mm 52W 2x18W RitzaNL/7/18 740mm 60W 2x18W / 1x9W CFL Ritza/13/ mm 41W 36W Ritza/13/2x mm 84W 2x36W RitzaNL/13/2x mm 98W 2x36W / 1x9W CFL Ritza/16/ mm 63W 58W Ritza/16/2x mm 156W 2x58W RitzaNL/16/2x mm 165W 2x58W / 1x9W CFL NL - with Night Light Edo Suitable for use in prison cell subway, magistrate/police holding cells, railway stations and small factories Vandal resistant screws SABS certified complying with SABS/IEC Ordering example: Product Name/CRI/Kelvin/Wattage (e.g. Blaz/80/50/21) Module - T8 Lamps Surface Mounted Powder Coated 304 or 316 Stainless Steel Body Clear Polycarbonate Lens - CODE Length W (system) Lamp Edo/3/35 355mm 35W 2x11W CFL Edo/6/52 686mm 52W 2x18W EdoNL/6/60 686mm 60W 2x18W / 1x9W CFL Edo/13/ mm 41W 1x36W Edo/13/ mm 89W 2x36W EdoNL/13/ mm 98W 2x36W / 1x9W CFL Edo/16/ mm 63W 1x58W Edo/16/ mm 156W 2x58W EdoNL/16/ mm 165W 2x58W / 1x9W CFL NL - with Night Light 22 Province Lighting Prison Luminaires LED Protected Catalogue

23 Prison Luminaires LED Protected Catalogue Province Lighting 23

24 Head Office Cape Town 100 Upper Canterbury Street, Cape Town Johannesburg Unit 5a Galaxy Park, Galaxy Road, Linbro Park Pretoria Unit 11, Lenchen Park, Lenchen Road South, Centurion Tel: Namibia Unit 2 Tesoro Building, 31 TV More Street, Windhoek FACEBOOK DISCLAIMER: While every effort has been made to ensure that the information contained within this catalogue is accurate and up to date, Province Lighting makes no warranty, representation or undertaking whether expressed or implied, nor does it assume any legal liability, whether direct or indirect, or responsibility for the accuracy, completeness, or usefulness of any information.

ATM Lighting sp. z o.o

ATM Lighting sp. z o.o INSTALLATION AND MAINTENANCE MANUAL FOR EXPLOSIONPROOF LIGHT FITTING EXL210LED Carefully read the instructions before mounting the light fitting. ATM Lighting sp. z o.o., ul. Budowlanych 31, 80-298 Gdańsk,

More information

ATM Lighting sp. z o.o

ATM Lighting sp. z o.o INSTALLATION AND MAINTENANCE MANUAL FOR EXPLOSIONPROOF LIGHT FITTING EXL390LED Carefully read the instructions before mounting the light fitting. ATM Lighting sp. z o.o., ul. Budowlanych 31, 80-298 Gdańsk,

More information

TPPL TUBULAR PROFESSIONAL PERFORMANCE LIGHTING SMART LIGHTING FOR HARSH ENVIRONMENTS

TPPL TUBULAR PROFESSIONAL PERFORMANCE LIGHTING SMART LIGHTING FOR HARSH ENVIRONMENTS TPPL TUBULAR PROFESSIONAL PERFORMANCE LIGHTING SMART LIGHTING FOR HARSH ENVIRONMENTS ATEX DIRECTIVES The ATEX directives 2014/34/EU & 1999/92/EC are commonly referred to as the two European Directives

More information

Overview of Hazardous Locations as They Relate to Solenoid Valves

Overview of Hazardous Locations as They Relate to Solenoid Valves Overview of Hazardous Locations as They Relate to Solenoid Valves Defined: Hazardous Location - "where fire or explosion hazards may exist due to flammable gases or vapors, flammable liquids, combustible

More information

60W Flameproof LED Emergency Linear Fixture V AC - (2) 30W LED Lamps - ATEX/IECEx

60W Flameproof LED Emergency Linear Fixture V AC - (2) 30W LED Lamps - ATEX/IECEx 60W Flameproof LED Emergency Linear Fixture - 100-250V AC - (2) 30W LED Lamps - ATEX/IECEx Part #: ATEX-HALP-EMG-48-2L-LED-2X30W-R1-220V Page: 1 The Larson Electronics ATEX-HALP-EMG-48-2L-LED-2X30W-R1-220V

More information

Guide for hazardous areas

Guide for hazardous areas Guide for hazardous areas 1 Hazardous areas definitions 2 Gas and dust s 3 Temperature classifications 4 Common flammable gases, vapours and dust types 5 Protection concepts ATEX and IECEx 6 Protection

More information

Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE

Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE PUE HX5.EX explosion-proof hazardous area indicator ATEX APPROVAL PUE HX5.EX is a cutting-edge weighing indicator, designed to

More information

LED Exterior Ground Catalogue

LED Exterior Ground Catalogue LED Exterior Ground Catalogue Q2-18 Contents 06 Welcome 07 Exterior Ground 18 220V GU10 04 Province Lighting Contents LED Exterior Ground Catalogue LED Exterior Ground Catalogue Province Lighting 05

More information

Selection of Explosion Protected Equipment for Hazardous Locations. Compiled by: Pieter Coetzee ZONE 2 ZONE 1 ZONE 0.

Selection of Explosion Protected Equipment for Hazardous Locations. Compiled by: Pieter Coetzee ZONE 2 ZONE 1 ZONE 0. Selection of Explosion Protected Equipment for Hazardous Locations Compiled by: Pieter Coetzee ZONE 2 ZONE 0 ZONE 1 Be safe be Ex Contents Introduction Occupational Health and Safety Act. (Act 85 of 1993)

More information

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required) FLUORESCENT LIGHTING RMS-560.. Series - Fluorescent lighting fixtures TECHNICAL FEATURES RMS.. series lighting fixtures are ideally suited for ON and OFF-SHORE applications and all kinds of industries

More information

ARRAN LED LED FLOODLIGHT. Standard Specification. Features

ARRAN LED LED FLOODLIGHT. Standard Specification. Features ARRAN LED LED FLOODLIGHT The Arran LED floodlight range is low energy with an instant on output and up to 130,000 maintenance free hours. Specifically designed for applications where moisture, dirt or

More information

ATEX, NOMENCLATURE AND CODING

ATEX, NOMENCLATURE AND CODING Technical Notes ATEX, NOMENCLATURE AND CODING The intent of this technical note is approach to the user to the ATEX normative. For this we will begin defining, what is an explosive atmosphere, what are

More information

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC EUROPEAN ATEX DIRECTIVE > European Directive 2014/34/EU ATEX Directive 2014/34/EU is a "new approach" directive that applies to protective systems against explosions as well as all equipment used in or

More information

EXPLOSIONPROOF LED LIGHT FITTINGS TO USE IN ZONES 1,21 & 2,22 KDB 15ATEX0049X NEW

EXPLOSIONPROOF LED LIGHT FITTINGS TO USE IN ZONES 1,21 & 2,22 KDB 15ATEX0049X NEW EXPLOSIONPROOF LED LIGHT FITTINGS TO USE IN S 1,21 & 2,22 KDB 150049X NEW WORK WITH GDANSK / Poland ABOUT US ATM Lighting is a Polish manufacturer of technical light fittings for various industry sectors.

More information

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS Hazardous Areas - EXPLOSIONPROOF SOLENOIDS SOME HISTORY The classification of hazardous areas into zones established the level of protection required for electrical equipment installed in explosive gas

More information

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white . TECHNICAL DATA LIGHT FITTING REFLECTOR Polycarbonate tube of 4 mm. thickness Laquered steel painted white END CAPS Aluminium 2030 (polyester paint RAL 7047) POWER SOURCE LAMP TYPE 220-240V, 50/60Hz T8

More information

ATEX, NOMENCLATURE AND CODING

ATEX, NOMENCLATURE AND CODING ATEX, NOMENCLATURE AND CODING The intent of this technical note is approach to the user to the ATEX normative. For this we will begin defining, what is an explosive atmosphere, what are ATEX, as well as

More information

CoreLine Waterproof the clear choice for LED

CoreLine Waterproof the clear choice for LED Lighting CoreLine Waterproof the clear choice for LED CoreLine Waterproof Whether for a new building or renovation of an existing space, customers want lighting solutions that provide quality of light

More information

HAZARDOUS AREA CLASSIFICATION AND SELECTION OF EQUIPMENT FOR SAFE USE THEREIN FROM AN ELECTRICAL VIEWPOINT

HAZARDOUS AREA CLASSIFICATION AND SELECTION OF EQUIPMENT FOR SAFE USE THEREIN FROM AN ELECTRICAL VIEWPOINT HAZARDOUS AREA CLASSIFICATION AND SELECTION OF EQUIPMENT FOR SAFE USE THEREIN FROM AN ELECTRICAL VIEWPOINT Olof Bekker Pr. Eng. BSc. Eng. BML S.MSAIEE, M.NACE Engineering Manager, Electrical COMMITMENT

More information

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt Airo Wireless Intrinsically Safe White Paper Written By: David Schmitt Intrinsically Safe Cell Phone/Smartphone/PDA Intrinsically Safe (IS) is a protection certification for safe operation with electronic

More information

JAMIN 100. Compact impervious luminaire for ATEX zones. Zones 2, 21, 22

JAMIN 100. Compact impervious luminaire for ATEX zones. Zones 2, 21, 22 JAMIN 100 Compact impervious luminaire for ATEX zones Zones 2, 21, 22 JAMIN 100 ATEX LIGHTING THEY TRUST US: ACETEX CHIMIE, ADISSEO, ADNATCO (Abu Dhabi National Tanker Company), Airbus, BRITISH PETROLEUM,

More information

Ex LED light fittings

Ex LED light fittings About us TEP Ex is a regional leader in manufacturing of explosion-protected electrical equipment. Through continuous development of new products and markets, modernization of technology and investment

More information

Sylproof Superia LED G2

Sylproof Superia LED G2 Range Features 665mm, 1265mm, 1565mm single and twin weatherproof LED luminaires Impresive performance, up to 7,837lm (luminaire lument output on 80W twin / double version) High efficiency, will help you

More information

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors Drive Technology \ Drive Automation \ System Integration \ Services *23511257_0817* Inquiry Forms for Explosion-Proof Gearmotors Edition 08/2017 23511257/EN SEW-EURODRIVE Driving the world Inquiry forms

More information

Beamex. Calibration White Paper. Calibration in hazardous areas

Beamex. Calibration White Paper.   Calibration in hazardous areas Beamex Calibration White Paper info@beamex.com Calibration in hazardous areas This article discusses calibration in hazardous areas and what everyone needs to be aware of before entering into a hazardous

More information

Trusted worldwide since 1989 INTRINSICALLY SAFE RANGE

Trusted worldwide since 1989 INTRINSICALLY SAFE RANGE Trusted worldwide since 1989 INTRINSICALLY SAFE RANGE Trusted worldwide We are now in our 28th year designing and manufacturing portable rechargeable lighting systems. Our main objective is to offer high

More information

1. GENERAL TECHNICAL INFORMATION

1. GENERAL TECHNICAL INFORMATION 1. GENERAL TECHNICAL INFORMATION 1.1 EXPLOSIVE ATMOSPHERES: Every time that dangerous quantities and concentration of flammable gas, vapors mixture or dust clouds exists, risk of explosions may arise.

More information

Beamex Calibration White Paper. Calibration in hazardous areas

Beamex Calibration White Paper.  Calibration in hazardous areas Beamex Calibration White Paper info@beamex.com Calibration in hazardous areas This article discusses calibration in hazardous areas and what everyone needs to be aware of before entering into a hazardous

More information

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here.

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here. A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here Introduction Potentially Explosive Atmospheres exist where there is a risk

More information

PRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres

PRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres PRODUCT OVERVIEW Light fittings, boxes & custom built control panels for explosive atmospheres LIGHT FITTINGS, BOXES & CUSTOM BUILT CONTROL PANELS FOR EXPLOSIVE ATMOSPHERES Light fittings for all zones

More information

26 Watt Explosion Proof Low Profile LED Fixture - 3,380 Lumens - Class 1 & 2 Div 1 & 2 - ATEX / IECE

26 Watt Explosion Proof Low Profile LED Fixture - 3,380 Lumens - Class 1 & 2 Div 1 & 2 - ATEX / IECE 26 Watt Explosion Proof Low Profile LED Fixture - 3,380 Lumens - Class 1 & 2 Div 1 & 2 - ATEX / IECE Part #: EPL-LP-12-LED Page: 1 The EPL-LP-12-LED from Larson Electronics is a Low Profile Explosion Proof

More information

RE: USE OF FIREPRO IN POTENTIALLY EXPLOSIVE ATMOSPHERES

RE: USE OF FIREPRO IN POTENTIALLY EXPLOSIVE ATMOSPHERES Limassol 20 th August, 2015 RE: USE OF FIREPRO IN POTENTIALLY EXPLOSIVE ATMOSPHERES This document is intended to provide clarification on the use of FirePro Condensed Aerosol Generators in Potential Explosive

More information

3F Linda Inox 1x.. T8 HF ATEX II 3D T85 C IP65

3F Linda Inox 1x.. T8 HF ATEX II 3D T85 C IP65 3F Linda Inox 1x.. T8 HF ATEX II 3D T85 C IP65 Product Technical Sheet 18, 36 and 58W single-lamp versions ST.0914.I Summary Application field 3 Structural characteristics 4 Electrical characteristics

More information

INTRINSICALLY SAFE LIGHTING RANGE

INTRINSICALLY SAFE LIGHTING RANGE Trusted worldwide since 1989 INTRINSICALLY SAFE LIGHTING RANGE SAFE PORTABLE RECHARGEABLE AC MAINS Trusted worldwide We are now in our 28th year designing and manufacturing portable rechargeable lighting

More information

LED NEW FB-SERIES LED NEW-SF FIXTURE LED NEW-SD FLOODLIGHT LED NEW-SD STREET. LED Explosion-proof Platform Light. LED Tri-proof Light

LED NEW FB-SERIES LED NEW-SF FIXTURE LED NEW-SD FLOODLIGHT LED NEW-SD STREET. LED Explosion-proof Platform Light. LED Tri-proof Light LED NEW FB-SERIES LED NEW-SF FIXTURE LED Explosion-proof Platform Light LED Tri-proof Light LED Explosion-proof Highbay Light LED NEW-CF FIXTURE LED Highbay Light LED Explosion-proof Light LED Explosion-proof

More information

CoreLine Batten the clear choice for LED

CoreLine Batten the clear choice for LED Lighting CoreLine Batten the clear choice for LED CoreLine Batten Whether for a new building or renovation of an existing space, customers want lighting solutions that provide quality of light and substantial

More information

UL HAZARDOUS LOCATIONS SERVICES

UL HAZARDOUS LOCATIONS SERVICES UL HAZARDOUS LOCATIONS SERVICES The international preference in hazardous locations certification for over 100 years ul.com/hazloc Explosive Gas Atmospheres Class I Division S Includes flammable gases,

More information

208W Explosion Proof Low Profile LED - Emergency Backup - 27,040 Lumens - C1&2 D1&2 - ATEX /IEC

208W Explosion Proof Low Profile LED - Emergency Backup - 27,040 Lumens - C1&2 D1&2 - ATEX /IEC 208W Explosion Proof Low Profile LED - Emergency Backup - 27,040 Lumens - C1&2 D1&2 - ATEX /IEC Part #: EPL-EMGX-LP-2X48-LED Page: 1 The Larson Electronics EPL-EMGX-LP-2X48-LED Low Profile Explosion Proof

More information

Selecting a Safe Tank Gauging Product. Understanding Hazardous Area Definitions for Equipment Approvals

Selecting a Safe Tank Gauging Product. Understanding Hazardous Area Definitions for Equipment Approvals Selecting a Safe Tank Gauging Product Understanding Hazardous Area Definitions for Equipment Approvals Hazardous Area Approvals A Worldwide Requirement There are many environmental considerations within

More information

WHAT WHITE PAPER IS POTENTIALLY EXPLOSIVE ATMOSPHERE CERTIFICATION AND WHY YOU. June 2010

WHAT WHITE PAPER IS POTENTIALLY EXPLOSIVE ATMOSPHERE CERTIFICATION AND WHY YOU. June 2010 WHITE PAPER WHAT IS POTENTIALLY EXPLOSIVE ATMOSPHERE CERTIFICATION AND WHY YOU MAY NEED IT! June 2010 Copyright Extronics Ltd 2010 The information contained in this document is subject to change without

More information

Affordable and reliable energy saving LED Lighting Luminaires

Affordable and reliable energy saving LED Lighting Luminaires Lighting Affordable and reliable energy saving LED Lighting Luminaires Smartbright Waterproof G2 SmartBright Waterproof G2 is an innovation from SmartBright Waterproof G1, can be used to replace traditional

More information

ATEX. Wolf Safety Lamp Company. The widest range of portable ATEX lighting approved for use in explosive atmospheres

ATEX. Wolf Safety Lamp Company. The widest range of portable ATEX lighting approved for use in explosive atmospheres Includes NEW ATEX Fluorescent Leadlamp Range Wolf Safety Lamp Company The widest range of portable ATEX lighting approved for use in explosive atmospheres Wolf Safety have Ex lighting products for all

More information

25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL

25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL 25W Hazardous Location Integrated LED Light Fixture - 3294 Lumens - Low Profile - ATEX IEC CSA UL Part #: HAL-19-25W-ITG-LED Page: 1 The Larson Electronics HAL-19-25W-ITG-LED 25 Watt Explosion Proof Low

More information

Guidelines for Market Surveillance of Equipment for Explosive Environments (Hazardous Locations)

Guidelines for Market Surveillance of Equipment for Explosive Environments (Hazardous Locations) Annex II Guidelines for Market Surveillance of Equipment for Explosive Environments (Hazardous Locations) 1. According to Recommendation L, market surveillance should be included as a flanking area of

More information

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Dräger Polytron 5700 IR Detection of flammable gases and vapours Dräger Polytron 5700 IR Detection of flammable gases and vapours The Dräger Polytron 5700 IR is a cost effective explosion-proof transmitter for the detection of flammable gases in the lower explosive

More information

Integrated Solutions Low Voltage Systems

Integrated Solutions Low Voltage Systems Integrated Solutions Low Voltage Systems 612 Contents Energy Distribution Overview Module Technology 8146 614 Overview Flameproof Enclosures 8220 614 Overview Flameproof Enclosures 8261 614 Overview CUBEx

More information

Guide to Hazardous Location Approvals:

Guide to Hazardous Location Approvals: Selection Guide Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches Introduction There are many considerations when selecting a switch to be used in hazardous areas. In addition

More information

Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches

Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches A Selection Guide Introduction There are many considerations when selecting a switch to be used in hazardous areas. In

More information

100W Explosion Proof Low Bay AC LED Fixture - C1D1 - C2D1 - Group B + ATEX/IECEX - IP67 Waterproof

100W Explosion Proof Low Bay AC LED Fixture - C1D1 - C2D1 - Group B + ATEX/IECEX - IP67 Waterproof 100W Explosion Proof Low Bay AC LED Fixture - C1D1 - C2D1 - Group B + ATEX/IECEX - IP67 Waterproof Part #: EPLX-HB-100W-RD2-LED-TRC Page: 1 The EPLX-HB-100W-RD2-LED-TRC Explosion Proof Low Bay AC LED light

More information

Low Profile Clean Room 150W LED Light - 2x2 Lay-In Troffer C1D1 - C2D2 - ISO 14644/FS-209E

Low Profile Clean Room 150W LED Light - 2x2 Lay-In Troffer C1D1 - C2D2 - ISO 14644/FS-209E Low Profile Clean Room 150W LED Light - 2x2 Lay-In Troffer - 140 - C1D1 - C2D2 - ISO 14644/FS-209E Part #: HALD-24-1X150LED-V2-140DB Page: 1 Made in the USA The HALD-24-1X150LED-V2-140DB from Larson Electronics

More information

40W Explosion Proof LED Light Fixture - C1D1, C2D1-2x2 Lay-in Troffer - ATEX/ISO Rated

40W Explosion Proof LED Light Fixture - C1D1, C2D1-2x2 Lay-in Troffer - ATEX/ISO Rated 40W Explosion Proof LED Light Fixture - C1D1, C2D1-2x2 Lay-in Troffer - ATEX/ISO Rated Part #: HALD-24-1X40CPR-LED-V2 Page: 1 The Larson Electronics HALD-24-1X40CPR-LED-V2 Explosion Proof LED Fixture provides

More information

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support The R. STAHL Technology Group Worldwide Success with Competence and Customer Support The entrepreneurial basis of the R. STAHL Technology Group follows a long tradition. The product range is aimed at specialised

More information

PREMIUM LUX 90LED VISIBLE

PREMIUM LUX 90LED VISIBLE No. 568 / 06.01.2015, Edition No. 7, 1/5 Industrial high bay projector PREMIUM LUX 90LED VISIBLE PREMIUM LUX 90 LED VISIBLE 6500K About the product The product Premium Lux LED is designed for general indoor

More information

Explosion-proof Immersion Heater Type D-8660

Explosion-proof Immersion Heater Type D-8660 Explosion-proof Immersion Heater Type D-8660 Sinus Jevi has developed explosionproof Ex de heating equipment, for hazardous area. The flame-proof (d) enclosures have been designed for non save areas to

More information

LED Explosion Proof MXL-90/100/120 MXLK-45/60/80

LED Explosion Proof MXL-90/100/120 MXLK-45/60/80 Tel:070-8890-0888 Fax:0505-365-6262 LED Explosion Proof MXL-90/100/120 MXLK-45/60/80 LED Flameproof Luminaires MXL LED Ex-Proof Lamps 90W/100W/120W Little trouble during operating and long life span due

More information

25W Explosion Proof Surface Mount LED Light - C1D1-2 - C2D1-2 - Aluminum Frame V AC

25W Explosion Proof Surface Mount LED Light - C1D1-2 - C2D1-2 - Aluminum Frame V AC 25W Explosion Proof Surface Mount LED Light - C1D1-2 - C2D1-2 - Aluminum Frame - 120-277V AC Part #: EXHL-TRN-LE1-1227 Page: 1 Made in Texas The EXHL-TRN-LE1-1227 from Larson Electronics is an Explosion

More information

Electrical Installations Design, Selection, Erection and Inspection

Electrical Installations Design, Selection, Erection and Inspection IECEx International Conference 2018 Jakarta, Indonesia Electrical Installations Design, Selection, Erection and Inspection IECEx International Conference 2018 Jakarta, Indonesia Peter Thurnherr thuba Ltd.,

More information

Micro and Mini Torch. Zones: 0, 1, 2, 20, 21 and 22. Product Overview. Features & Benefits. Certifications

Micro and Mini Torch. Zones: 0, 1, 2, 20, 21 and 22. Product Overview. Features & Benefits. Certifications Micro and Mini Zones: 0, 1, 2, 20, 21 and 22 Product Overview Features & Benefits The Micro and Mini es use high-tech light sources to give impressive performance with a compact size, designed for easy

More information

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236 CONTENT 1. Manufacturer 1 2. General safety informations 1 3. Purpose 2 4. Product compliance 2 5. Degree of protection and technical data 2 6. Type 3 7. Mounting and installation 3 8. Dimensions 6 9.

More information

OPTIBAR DP 7060 Supplementary Instructions

OPTIBAR DP 7060 Supplementary Instructions OPTIBAR DP 7060 Supplementary Instructions Differential pressure transmitter Category ATEX II 1/2G, 2G Ex db ia IIC T6...T1 Ga/Gb, Gb IECEx Ex db ia IIC T6...T1 Ga/Gb, Gb Housing Aluminium: Single chamber,

More information

Flammable gases Detectors. Model DAX 03F DAX 03F- C DAX 03F- H. Note for installation, use and maintenance. Version 1.2

Flammable gases Detectors. Model DAX 03F DAX 03F- C DAX 03F- H. Note for installation, use and maintenance. Version 1.2 Flammable gases Detectors Model DAX 03F DAX 03F- C DAX 03F- H Note for installation, use and maintenance Version 1.2 Introduction This handbook must be read carefully by any person who has or will have

More information

S T R I T T & P R I E B E I N C.

S T R I T T & P R I E B E I N C. Equipment Enclosure Comparisons Type of Enclosure European - Area of use Designation Standard IEC - Area of use Designation Standard USA - Area of use Designation Standard Flameproof Enclosure An enclosure

More information

MICROpeL 75 Combustible Gas Sensor Part Number: PM

MICROpeL 75 Combustible Gas Sensor Part Number: PM MICROpeL 75 Combustible Gas Sensor Part Number: PM759-000 Key Features & Benefits: ATEX, UL and CSA Approvals Withstands EN/IEC 60079-0 impact test Enhanced H 2 S and silicone poison resistance Reduced

More information

CCA-03EX. - Easy installation - Low energy consumption - New COB LED technology - Zone 1, 2, 21, 22. Directional LED spotlights

CCA-03EX. - Easy installation - Low energy consumption - New COB LED technology - Zone 1, 2, 21, 22. Directional LED spotlights CCA-03EX - Easy installation - Low energy consumption - New COB LED technology - Zone 1, 2, 21, 22 Directional LED spotlights Body and lid in coated aluminium LED for proper operation monitoring 127 ED.2018

More information

EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU

EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU GENERAL The accidental ignition of an atmosphere containing a large quantity of gas, vapour, mists and/or dust may cause an explosion. Specific

More information

performance PowerBalance, surface mounted Benefits Features Application Specifications

performance PowerBalance, surface mounted Benefits Features Application Specifications Lighting PowerBalance surfacemounted sustainable performance PowerBalance, surface mounted When it comes to lighting an office space with LED luminaires, people are usually willing to invest in sustainability

More information

DTS Light fittings for explosive atmospheres

DTS Light fittings for explosive atmospheres DTS Light fittings for explosive atmospheres For all zones and industrial applications LIGHT FITTINGS FOR EXPLOSIVE ATMOSPHERES Light fittings for all zones and industrial applications Tubular glass light

More information

distributed by Sole Agent in Great China Universky (Jiangsu) Technologies, Inc. Phone: Fax:

distributed by Sole Agent in Great China Universky (Jiangsu) Technologies, Inc. Phone: Fax: distributed by Sole Agent in reat China Universky (Jiangsu) Technologies, Inc. #7 Belt Lake (Lian hu) Industrial Park, anyang, Jiangsu, China 212300 Phone: +86 511 86537777 Fax: +86 511 8628263 E-mail:

More information

Test procedure/ method name. method identification. Testing of industrial and explosion isolation valves and tank lining

Test procedure/ method name. method identification. Testing of industrial and explosion isolation valves and tank lining The Laboratory is qualified to update standards identifying the test procedures. The laboratory requires/applies a flexible scope of accreditation permitted as detailed in the Annex. Updated list of activities

More information

Specification Sheet. Certificates. Features. Application. Anti-Explosive Lamp

Specification Sheet. Certificates. Features. Application. Anti-Explosive Lamp Anti-Explosive Lamp Specification Sheet Product Introduction ALT's anti-explosive lamp can be safely used in hazardous locations such as power plants, oil and natural gas drilling stations and refineries,

More information

Smart encoders & actuators

Smart encoders & actuators Declaration of Conformity The manufacturer: LIKA ELECTRONIC SRL 36010 Carrè (VI) - Italy hereby declares that the following products (only when correctly assembled): XAC8018/1PB-14 XAC8018/1CB-14 XAC8018/1FD-14

More information

Certificate of Compliance

Certificate of Compliance FF0 001 Certificate of Compliance Certificate: 70116284 (LR 064969_0_00) Issued to: Mine Safety Appliances Company North American Division 1000 Cranberry Woods Dr Cranberry Township, Pennsylvania 16066-5296

More information

Ledinaire Batten Simply great LED

Ledinaire Batten Simply great LED Lighting Simply great LED The Ledinaire range contains a selection of popular off-the-shelf LED luminaires that comes with the high Philips quality levels at a competitive price. Reliable, energy efficient

More information

[ TECHNOLOGY ] and does this definition affect a burner.

[ TECHNOLOGY ] and does this definition affect a burner. [ TECHNOLOGY ] JBD-11,500-G type burner for natural gas ATEX, EExd Zone 2. For combined cycle power plant in Riga Latvia. Aitor Fernández Project Engineer Automation Department Head afernandez@emcombustion.es

More information

ELECTRICAL EX EQUIPMENT

ELECTRICAL EX EQUIPMENT ELECTRICAL EX EQUIPMENT in hazardous areas Enclosures Reliable Customized Solutions Leader in Explosion Proof Protections CB Control Panel Configuration - Gas group IIB / Dust group IIIC Ex d enclosures

More information

Introduction to Hazardous Electrical Location Classifications

Introduction to Hazardous Electrical Location Classifications Introduction to Hazardous Electrical Location Classifications Introduction In North America the target audience for this white paper and the electrical code classification ratings for various types of

More information

EVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation

EVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation EVL-B Shock-resistant tempered glass - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation costs - Suitable for GAS category IIC LED

More information

High Quality LED Lighting!

High Quality LED Lighting! High Quality LED Lighting! IP65 GB Code: Ex ib II CT4 GB Certificate CNEx09.0865 Standard: GB3836.1-2000 GB3836.4-2000 Cree LED Light Source PC Shell Portable Mountable on a safety helmet Energy Saving

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExS110D and BExS110D-R Sounder For use in Flammable Gas and Dust Atmospheres BExS110D BExS110D-R 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT

More information

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN Inspection Light LED Operating instructions Additional languages www.stahl-ex.com Contents 1 General Information...3 1.1 Manufacturer...3 1.2 Information regarding the operating instructions...3 1.3 Conformity

More information

Product Specifications MaxLumen MRI LED Diffused Lighting

Product Specifications MaxLumen MRI LED Diffused Lighting NOVA Energy & Automation Product Specifications MaxLumen MRI LED Diffused Lighting Model MXLumen22-X 03 January 2012 Product Description 1. Standard Applications The Nova Max Lumen LED 2x2 light fixture

More information

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres 1) Introduction The BExBG05D-SIL is a flameproof beacon which is certified

More information

High bay LED lighting fixture

High bay LED lighting fixture Supporting bracket EWL - Zone 1, 2, 21, 22 - Replacing traditional discharge lamps of up to 750W - Savings in energy, maintenance and installation costs - Instant, brilliant illumination - Suitable for

More information

Drive systems for the chemical, oil and gas industry. Electric drives and systems

Drive systems for the chemical, oil and gas industry. Electric drives and systems Drive systems for the chemical, oil and gas industry Electric drives and systems 2 VEM drive systems for the chemical, oil and gas industry VEM drive systems for the chemical, oil and gas industry 3 VEM

More information

ATEX Safety Switches. More than safety.

ATEX Safety Switches. More than safety. ATEX Safety Switches More than safety. AUDIN - 8, avenue de la malle - 5370 Saint Brice Courcelles Tel : 03.6.0.0. - Fax : 03.6.0.8.0 - Web : http: www.audin.fr - Email : info@audin.fr ATEX products from

More information

CLASS I LOCATIONS ZONE CLASSIFICATION

CLASS I LOCATIONS ZONE CLASSIFICATION HAZARDOUS (CLASSIFIED) LOCATIONS Hazardous locations are those locations where the risk of a fire or explosion may exist due to the presence of flammable gases or vapors, flammable liquids, combustible

More information

ATEX - ATmosphere EXplosive

ATEX - ATmosphere EXplosive ATEX - ATmosphere EXplosive 153 DIRECTIVE 94/9/CE (ATEX= ATMOSPHERE EXPLOSIVE) OF THE EUROPEAN PARLIAMENT AND COUNCIL (MARCH 23, 1994): IMPACT ON LIGHTING FIXTURES APPLICATIONS Polycarbonate and steel

More information

Dual certification! Air handling units for potentially explosive atmospheres

Dual certification! Air handling units for potentially explosive atmospheres Dual certification! Air handling units for potentially explosive atmospheres X-CUBE Ex A certified safety product The air handling unit with dual ATEX certification ATEX directive 2014/34/EU applies to

More information

INSTRUCTION & SERVICE MANUAL

INSTRUCTION & SERVICE MANUAL INSTRUCTION & SERVICE MANUAL D2xC1 ALARM HORN AND STROBE For Use In Hazardous Locations 3) Ratings and Markings 3.1 ATEX / IECEx certification The D2xC1 Alarm Horn and Strobe complies with the following

More information

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC Quick Introduction to TÛV Denmark TÜV Denmark - is a part of the TÜV NORD Group a global Organisation f Certification and Inspection of: Quality Management Systems, Products, Processes and Qualification

More information

D O M E S T I C LED. Lighting C O M M E R C I A L

D O M E S T I C LED. Lighting C O M M E R C I A L D O M E S T I C LED C O M M E R C I A L Vela Advance IP65 Dimmable LED 9W Fire Rated, Low Profile Downlights Fixed, tilt & a n t i - g l a re options Option The VELA Advance Range offers a High Quality

More information

Explosion-protected actuator Page 259 of 292

Explosion-protected actuator Page 259 of 292 Explosion-protected actuator Page 259 of 292 9.5 Explosion-protected actuator 9.5.1. What is an explosion? A flammable substance and oxygen, in a certain mixture, must be available to set off an explosion.

More information

standards: standards:

standards: standards: INSTRUCTION MANUAL D2xB1LD2 LED Beacons For use in Hazardous Locations 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGISED POTENTIAL ELECTROSTATIC CHARGING HAZARD

More information

24V-Ex Power Supply INTRINSICALLY SAFE

24V-Ex Power Supply INTRINSICALLY SAFE TM 24V-Ex Power Supply INTRINSICALLY SAFE 1 Description of an Explosion Protected DC Power Supply Explosion Protection for DC POWER In the manufacture, processing, transport and storage of flammable materials

More information

IRceL CH4 Methane (CH 4

IRceL CH4 Methane (CH 4 Product Datasheet IRceL CH4 Methane Sensor Document Purpose The purpose of this document is to present the performance specification of the IRceL CH4 Methane gas sensor. This document should be used in

More information

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218 CONTENT 1. Manufacturer 1 2. General safety informations 1 3. Purpose 2 4. Product compliance 2 5. Degree of protection and technical data 2 6. Type 3 7. Mounting and installation 3 8. Dimensions 6 9.

More information

BC9700 series High Power LED Explosion Proof Light

BC9700 series High Power LED Explosion Proof Light BC9700 series High Power LED Explosion Proof Light Characteristics IECEx ATEX LM79 LM8 IP 66 Ta 0/55 Ta -0 Application Zone,zone ;zone,zone Suitable for Low installation height in Moist corrosive environment,such

More information

ATEX. Wolf Safety Lamp Company. Includes NEW LinkEx LED. The widest range of portable ATEX lighting approved for use in explosive atmospheres

ATEX. Wolf Safety Lamp Company. Includes NEW LinkEx LED. The widest range of portable ATEX lighting approved for use in explosive atmospheres Includes NEW LinkEx LE Wolf Safety Lamp Company The widest range of portable ATEX lighting approved for use in explosive atmospheres Wolf Safety have Ex lighting products for all purposes, the correct

More information

Certificate of Compliance

Certificate of Compliance FF0 001 Certificate of Compliance Certificate: 70116279 (LR 025993_0_000) Issued to: General Monitors, Incorporated 26776 Simpatica Circle Lake Forest, California 92630 USA Attention: Larry Vlagea The

More information

Implementation of ATEX Guidelines

Implementation of ATEX Guidelines Implementation of ATEX Guidelines Temperature and Climatic Test Chambers for Usage under Conditions Carrying a Risk of Fire and Explosion What are ATEX guidelines? Introduction Duties of the system user...

More information