WT7502 PC POWER SUPPLY SUPERVISOR. Data Sheet REV Feb. 26, 2008
|
|
- Cora Boone
- 5 years ago
- Views:
Transcription
1 ` 偉詮電子股份有限公司 WT7502 PC POWER SUPPLY SUPERVISOR Data Sheet REV Feb. 26, 2008 The information in this document is subject to change without notice. All Rights Reserved. 新竹市科學工業園區工業東九路 24 號 2 樓 2F, No. 24, Industry E. 9 th RD., Science-Based Industrial Park, Hsin-Chu, Taiwan TEL: FAX: support@weltrend.com.tw
2 GENERAL DESCRIPTION The WT7502 provides protection circuits, power good output (), fault protection latch (), and a protection detector function () control. It can minimize external components of switching power supply systems in personal computer. The Over / Under Voltage Detector (OVD / UVD) monitors V33, V5 and VCC input voltage level. When OVD or UVD detect the fault voltage level, the is latched HIGH and go low. When detect the fault voltage level, the would be kept LOW and go low. The latch can be reset by go HIGH. There is 3.5 ms delay time for turn off. When and OVD and UVD detect the right voltage level, the power good output () will be issue. FEATURES The Over / Under Voltage Detector (OVD / UVD) monitors V33, V5 and VCC input voltage. Both of the power good output () and fault protection latch () are Open Drain Output. 75 ms time delay for UVD. 300 ms time delay for. 38 ms for input signal De bounce. 73 us for / UVD internal signal De glitches. 55 us for OVD internal signal De glitches. 3.5 ms time delay for turn-off. The UVD would been disabled when < 1.2V. PIN ASSIGNMENT AND PACKAGE TYPE WT7502 GND VCC V5 V33 ORDERING INFORMATION PACKAGE 8 Pin Plastic DIP 8 Pin Plastic SOP CHIP WT7502 N084 WT7502 S084 WT7502-HXXX Lead Free(Pb) WT7502 N084 Pb WT7502 S084 Pb The Top-Side Marking would be added a dot( ) ( )in the right side for lead-free package. Page 2
3 PIN DESCRIPTION Pin Name TYPE Description I Power good input signal pin GND P Ground O Fault protection output pin, open drain output I On/Off switch input V33 I 3.3V over voltage & under voltage & over current sense input pin V5 I 5V over voltage & under voltage & over current sense input pin VCC I Power supply O Power good output signal pin, open drain output BLOCK DIAGRAM WT7502 VCC PWR Power On Reset PWR VCCI 1.2V ~ 1.8V 38ms debounce 3.5ms delay V33 - UN + - OV + 75ms delay Bandgap Reference Internal Power VREF = 1.2V VCCI = 3.6V V5 + - UN VCC - OV + - UN + 73us debounce PWR OSC CLK + - OV 1.2V 55us debounce R S Q 1.2V + - UN 73us debounce 300ms delay Page 3
4 ABSOLUTE MAXIMUM RATINGS Parameter Min. Max. Unit Supply voltage, VCC V Input voltage,, V5, V VCC + 0.3(Max. 7V) V Output voltage V V Operating temperature Storage temperature *Note: Stresses above those listed may cause permanent damage to the devices RECOMMENDED OPERATING CONDITIONS Parameter Conditions Min. Typ. Max. Unit Supply voltage, VCC V Input voltage,, V5, V33 7 V Output voltage 7 V 15 V Output sink current 0.3V 10 ma 0.3V 10 ma Supply voltage rising time 1 ms ELECTRICAL CHARACTERISTICS, at Ta=25 C and V CC =5V. Over Voltage Detection Parameter Condition Min. Typ. Max. Unit V V Over voltage threshold V V VCC V I LEAKAGE Leakage current () V() = 5V 5 ua V OL Low level output voltage () I sink =10mA 0.3 I sink =30mA 0.7 V Under Voltage Detection Parameter Condition Min. Typ. Max. Unit V V Under voltage threshold V V VCC V Input threshold voltage () V I LEAKAGE Leakage current () = 5V 5 ua V OL Low level output voltage() I sink =10mA 0.3 V Parameter Condition Min. Typ. Max. Unit Input pull-up current = 0V 150 ua High-level input voltage 1.8 V Low-level input voltage 1.2 V Page 4
5 TOTAL DEVICE Parameter Condition Min. Typ. Max. Unit Icc Supply current PDON _N= 5V 1 ma Vcc start-up voltage 3.6 V Vcc stop voltage after start-up 3.0 V SWITCHING CHARACTERISTICS, Vcc=5V Parameter Condition Min. Typ. Max. Unit De-bounce time () ms t delay1 Delay time ( to ) ms t db2 De-bounce time () ms t g1 De-glitch time for us t g2 De-glitch time for UVD us t g3 De-glitch time for OVD us t delay2 to delay time t db t db t db ms t delay3 Internal UVD delay time After go low & every time > 1.2V ms APPLICATION CIRCUIT +5V +5VSB +5VSB 1K R4=100 D1 +5VSB GND VCC +5VSB 10K V5 +5V R5= uF V V +12V NOTE1:The series resistor R5 at can not be omitted.(r0 = 300Ω is suggested) NOTE2:The series resistor R4 = 100Ω and diode D1 at is suggested. Page 5
6 APPLICATION TIMMING 1.) (UNDER_VOLTAGE) : t delay2 t db2 t g1 Page 6
7 2.) V33 / V5 / VCC UVD: t delay2 t db2 V33 / V5 / VCC t delay3 +t g2 t delay2 t db2 V33 / V5 / VCC Page 7
8 3.) V33 / V5 / VCC OVP: t delay2 t db2 V33 / V5 / VCC t g3 t delay2 t db2 V33 / V5 / VCC Page 8
9 MECHANICAL INFORMATION PLASTIC DUAL IN LINE 8PIN PACKAGE NOTE 1:All linear dimensions are in inches(millimeters). NOTE 2:This drawing is subject to change without notice. NOTE 3:Falls within JEDEC MS 001 Page 9
10 PLASTIC SMALL OUTLINE 8PIN PACKAGE NOTE 1:All linear dimensions are in inches(millimeters). NOTE 2:This drawing is subject to change without notice. NOTE 3:Falls within JEDEC MS 012 Page 10
PV Ribbon Hi-speed Tin-plating Machine List
PV Ribbon Hi-speed Tin-plating Machine List Project Name:PV Ribbon Hi-speed Tin-plating Machine Model:WP001 溫誠工業 ( 股 ) 有限公司 WEN CHENG LEAD WIRE CO., LTD. 台灣省桃園縣新屋鄉頭洲村 9 鄰 11 之 2 號 NO. 11-2, 9 Lin, Tou
More informationTC5F 熱流道溫度控制器 TC5F Hot-Runner Temperature 操作手冊 USER'S MANUAL. 長新科技股份有限公司 ARICO Technology Co., Ltd. 長新科技股份有限公司. Ver.:TC5F-1.0.2
長新科技股份有限公司 ARICO Technology Co., Ltd. Registered to ISO 9001 TC5F 熱流道溫度控制器 TC5F Hot-Runner Temperature 操作手冊 USER'S MANUAL Ver.:TC5F-1.0.2 長新科技股份有限公司 ARICO Technology Co., Ltd. 保有權利於任何時間未經通知而修改或變更本手冊內容及型式,
More information1Hz,16Hz, S2 S3 S4 S5 S6 S7 S8 ALARM REGISTER COMPARATOR WEEK SECONDS MINUTES HOURS DAYS MONTHS YEARS /12 1 /24 1 /7 /28-1 /31
REAL-TIME CLOCK WITH INTERNAL RAM RP/RF5C0A NO. EK-086-9804 OUTLINE The RP/RF5C0A are real-time clocks for microcomputers that can be connected directly to buses of microcomputers with such CPUs as the
More informationReplaced by A5367CA. DISCONTINUED PRODUCT SMOKE DETECTOR WITH INTERCONNECT AND TIMER FEATURES
Data Sheet 260.8 TIMER START I / O LOW-V SET TIMER OUT + SUPPLY TIMING RES. FEEDBACK 2 3 4 5 6 7 V DD LOGIC OSC. & TIMING DRIVER 8 V SS 9 ABSOLUTE MAXIMUM RATINGS (Voltages are referenced to V SS ) Supply
More informationDUAL MONITORED INPUT/OUTPUT UNIT BN-305
DUAL MONITORED INPUT/OUTPUT UNIT BN-30 Interactive fire detection systems Product Datasheet Features Interactive For interfacing and controlling external units to Autronica s interactive fire detection
More informationDISCONTINUED PRODUCT. For reference only SMOKE DETECTOR WITH INTERCONNECT FEATURES. ABSOLUTE MAXIMUM RATINGS (Voltages are referenced to V SS
WITH INTERCONNECT Data Sheet 60.6 NO CONNECT. I / O LOW-V SET NO CONNECT. LED + SUPPLY TIMING RES. FEEDBACK 3 4 5 6 7 NC NC LOGIC OSC. & TIMING DRIVER 0 6 5 4 3 8 V SS GUARD DETECT. IN GUARD SENSITIVITY
More informationHOA1888 Series. Infrared Assemblies Wide Gap Transmissive Sensor. MICRO SWITCH Sensing and Control
Wide Gap Transmissive Sensor HOA1888 Series FEATURES Choice of phototransistor or photodarlington output Visible ambient light and dust protective filter 12 mm (0.47 in.) slot width Snap-in housing The
More informationA5348 Ionization Smoke Detector with Interconnect and Timer
Features and Benefits Low average standby current for long battery life Interconnect up to 125 detectors Piezoelectric horn driver Guard outputs for detector input Pulse testing for low battery Power-on
More informationA5364. Ionization Smoke Detector with Interconnect
Features and Benefits Low average standby current for long battery life Interconnect up to 125 detectors Piezoelectric horn driver Guard outputs for detector input Pulse testing for low battery Power-on
More informationMission 份有限公司 wwwom 先锋科技股份有限公司 www Working with our customers we identify, design and deliver low light detection solutions which solve customer probl
份有限公司 wwwom 先锋科技股份有限公司 份有限公司 wwwom 先锋科技股份有限公司 www Radiation detection solutions for miniaturized pager and handheld markets sensl: light detection and measurement October - 2009 www.sensl.com 1 Mission
More informationDUAL MONITORED INPUT/OUTPUT UNIT BN-305-2
DUAL MONITORED INPUT/OUTPUT UNIT BN-305-2 Interactive fire detection systems Product Datasheet Features Interactive For interfacing and controlling external units to Autronica s interactive fire detection
More informationSPECIFICATION FOR APPROVAL
SPECIFICATION FOR APPROVAL CUSTOMER: JAMES PART NO: 1953612 MODEL NO: DESIGNED NO: DDU050100 M2270 RoHS REVISION: 1-2 CATEGORY: EI-48 REGULATED ADAPTOR DATE SUBMITTED: 2014.11.14 SAMPLE/SPECIFICATION SUBMITTED
More informationE PIR Motion Detector. Features. General Description. Applications. Single Sensor Application Circuit
E9.92 PIR Motion Detector Features Fully integrated PIR motion detector Digital signal processing On chip supply regulator with wide operating voltage range Low power consumption Temperature compensation
More informationTLM-8 User s Guide. Features and Description. Warranty. WATLOW TLM-8 User s Guide 1
TLM-8 User s Guide Features and Description The TLM-8 is a multi-zone temperature limit switch For thermal system safety, the TLM-8 can satisfy the requirement for independent temperature monitoring The
More informationMission 份有限公司 wwwom 先锋科技股份有限公司 www Working with our customers we identify, design and deliver low light detection solutions which solve customer probl
份有限公司 wwwom 先锋科技股份有限公司 www 份有限公司 wwwom 先锋科技股份有限公司 Solutions for Nuclear Medicine sensl: light detection and measurement Mission 份有限公司 wwwom 先锋科技股份有限公司 www Working with our customers we identify, design
More informationSPECIFICATION FOR APPROVAL
SPECIFICATION FOR APPROVAL CUSTOMER: JAMES PART NO: MODEL NO: DESIGNED NO: EDU120150 A2221 RoHS REVISION: 1-0 CATEGORY: AC ADAPTOR DATE SUBMITTED: 2016.03.15 SAMPLE/SPECIFICATION SUBMITTED SAMPLE 0 SPECIFICATION
More informationUNISONIC TECHNOLOGIES CO., LTD 88NXX
UNISONIC TECHNOLOGIES CO., LTD 88NXX BUILT-IN DELAY HIGH-PRECISION OLTAGE ECTOR DESCRIPTION The UTC 88NXX is a high-precision voltage detector developed basing on CMOS technology. The detection voltage
More informationSTATUS ALARM HISTORY ALARM RESET
Instruction Manual Model 1582-42L Data Switch February 1999, Rev 0 CH1 AUTO CH2 SWITCH 1 2 1 2 STATUS 1 2 MODEL 1582 SWITCH CROSS TECHNOLOGIES INC. CH1 ONLINE MANUAL SELECT CH2 ONLINE SWITCH RESET MAN
More informationSUNON SPECIFICATION FOR APPROVAL : SUNON INC : SPEC.NO D G-00 ISSUE DATE Dolphin 7/19 REVISION DATE
SPECIFICATION FOR APPROVAL CUSTOMER MOTOR TYPE DESCRIPTION DIMENSIONS M O D E L P/N SUNON SPEC. NO. CUSTOMER APPROVAL NO. APPROVED BY CUSTOMER (AUTHORIZED) : SUNON INC : : MagLev Motor Fan : 40X40X10 mm
More informationDS1286 Watchdog Timekeeper
www.dalsemi.com FEATURES Keeps track of hundredths of seconds, seconds, minutes, hours, days, date of the month, months, and years; valid leap year compensation up to 2100 Watchdog timer restarts an out-of-control
More informationGP2Y1010AU0F. Compact Optical Dust Sensor. Description. Compliance. Applications. Features GP2Y1010AU0F. 1. Compliant with RoHS directive (2002/95/EC)
GPY00AU0F Compact Optical Dust Sensor Description GPY00AU0F is a dust sensor by optical sensing system. An infrared emitting diode (IRED) and an phototransistor are diagonally arranged into this device.
More informationApex MediTech ALC109 ALARM SYSTEM
ALC109 ALARM SYSTEM PRIORITY ENCODED ALARM SYSTEM FOR MEDICAL DEVICES Rev. 04 28 November 2013 Product data sheet 1. General description The ALC109 is a hybrid priority encoded audio alarm, available in
More informationSUNON SPECIFICATION FOR APPROVAL. ISSUE DATE Alice
SPECIFICATION FOR APPROVAL CUSTOMER : MOTOR TYPE DESCRIPTION DIMENSIONS M O D E L P/N SUNON SPEC. NO CUSTOMER APPROVAL NO. APPROVED BY CUSTOMER (AUTHORIZED) : : MagLev Motor Fan : 92X92X25 mm : MA2092-HVL
More informationFPS CL Burst Mode SFF BIDI EPON ONU TRANSCEIVER(20Km)
FEATURES Dual Wavelength Bi-Directional Tx/Rx 1.25Gbps/1310nm Burst Mode Transmitter 1.25Gbps/1490nm CW Mode Receiver IEEE 802.3ah Compliant Single 3.3 Voltage Supply 2X10 SFF Package Outline Single Fiber
More informationK-Band Doppler Sensor Module
K-Band Doppler Sensor Module RF Frequency: 24.5 to 24.25 GHz Model No. NJR4262 s Rev.-2 February 26, 213 Copyright 213 New Japan Radio Co., Ltd. Microwave Components Division -Notice of Proprietary Information-
More informationSurface Mount Ambient Light Sensor PTAS-P1F1708CH6. Features. Descriptions. Applications. Device Selection Guide
Surface Mount Ambient Light Sensor Surface Mount Ambient Light Sensor Features Closely respond to human eye spectrum Light to current with analog output Good output linearity across wide illumination ranges
More informationSUNON SPECIFICATION FOR APPROVAL. CUSTOMER : DESCRIPTION : AC BLOWER DIMENSIONS : 120X120X31 mm M O D E L : AB2123-HST P/N : GN
SPECIFICATION FOR APPROVAL CUSTOMER : DESCRIPTION : AC BLOWER DIMENSIONS : 120X120X31 mm M O D E L : AB2123-HST P/N : GN SUNON SPEC. NO. : A12004440G-00 APPROVAL NO. : APPROVED BY : (AUTHORIZED) SPEC.NO
More informationTechnical Data Sheet 5mm Infrared LED, T-1
Technical Data Sheet 5mm Infrared LED, T-1 Features High reliability 2.54mm lead spacing Low forward voltage Good spectral matching to Si photodetector Pb free The product itself will remain within RoHS
More informationChapter 7. Troubleshooting
Chapter 7 Troubleshooting Table of Contents Page 1 Troubleshooting... 7-2 2 Failure analysis charts... 7-2 3 Alarm factor tree analysis chart... 7-8 7-1 1 Troubleshooting An IPM has various integrated
More informationFeatures. Applications
General Description The is a high performance AC/DC power supply controller for battery charger and adapter applications. The device uses Pulse Frequency Modulation (PFM) method to build discontinuous
More informationTaiwantrade Supplier Business Information Verification Report
Taiwantrade Supplier Business Information Verification Report Company Address: City / Country: Presented to SUN MINES ELECTRICS CO., LTD. 三敏電機股份有限公司 7F,No.153,Sec. 3,Beishen Rd., Shenkeng Dist., New Taipei
More informationisopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)
T M 1 isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded) Technical Bulletin NAE1012670 / 08.2013 isopv425
More information- For Continuous Radon Monitoring (CRM) Systems - Ultra Low Power Requirement
RN53 Radon Detector RN53 - For Continuous Radon Monitoring (CRM) Systems - Ultra Low Power Requirement Description The RN53 Radon Detector operates on the method of electrostatic collecting of the radon
More informationR&E International A Subsidiary of Microchip Technology Inc.
RE46C105 Piezoelectric Horn Driver with oltage Regulator and LED Driver General Description The RE46C105 is a piezoelectric horn driver with a voltage regulator and an open drain NMOS driver suitable for
More informationLow-Power CMOS ALARM IC with Horn Driver
Freescale Semiconductor Technical Data Low-Power CMOS ALARM IC with Horn Driver The MC Alarm IC is designed to simplify the process of interfacing an alarm level voltage condition to a piezoelectric horn
More informationFCX-11AB5-3XX-XX 155Mbps BIDI SFP TRANSCEIVER(100Km)
FEATURES LC or SC receptacle optical interface compliant Single 3.3V power supply Hot-pluggable Uncooled 1490nm DFB laser transmitter Receiver loss of signal output AC/AC Coupling according to MSA Transmitter
More informationRC801/803/ B 16E1 Fiber-Optic Multiplexer (Rev. M) User Manual. Raisecom Technology Co., Ltd. (04/2005)
RC801/803/805-480B 16E1 Fiber-Optic Multiplexer (Rev. M) User Manual Raisecom Technology Co., Ltd. (04/2005) 1. Cautions Please read the following notices carefully before installing and using the device,
More informationThe trademark of ARICO Technology Co. Ltd., consists of a white human icon, three squares and alphabets :
Hot Runner Plastic / Rubber Machine Slim Strong Relay Solid State Relay Ceramic Band Heaters Displacement Pressure Load Cells Inverters 長新科技股份有限公司 ARICO TECHNOLOGY CO., LTD. www.arico.com.tw INTRO-EN-1.1.0
More informationEnd To End Optical Beam Smoke Detector. Additional Information
End To End Optical Beam Smoke Detector Additional Information EN 1. Multiple Zone Wiring When using more than one System Controller on a single zone of a conventional Fire Control Panel (FCP), it is important
More informationVega Devices.
Vega Devices This document lists the Argus Vega devices that are compatible with the Panels. It also highlights any specific requirements and technical information. Range of Fire Alarm Control The operation
More informationDHM5150 Human Motion Sensor Module User Manual
DHM5150 Human Motion Sensor Module User Manual Version: 1.0.2 February 2005 Table of Contents I. Introduction 2 II. Operations 2 II.1. Theory of Operation 2 II.2. Running as Part of WiRobot System 3 II.3.
More informationTechnical Data Sheet 1.6mm Side Looking Phototransistor
Technical Data Sheet 1.6mm Side Looking Phototransistor Features Fast response time High sensitivity Small junction capacitance Pb free This product itself will remain within RoHS compliant version. Descriptions
More informationSTATUS ALARM ALARM HISTORY POWER HISTORY RESET
Instruction Manual Model 1582-152 RF Protection Switch November 2009, Rev B. CH1 AUTO CH2 SWITCH 1 2 1 2 STATUS 1 2 MODEL 1582 SWITCH CROSS TECHNOLOGIES INC. CH1 ONLINE MANUAL SELECT CH2 SWITCH MANUAL
More informationRev Flame Detection Sensor. TF100 User Manual
Rev. 0.94 User Manual The is a sensitive flame detection sensor. This sensor has been developed with efficient algorithm on the basis of actual flame conditions, using accurate calibration apparatus. This
More informationItem Symbol Rating Unit Power supply V CC 12.0 VDC Output voltage V OUT 3.0 VDC
MEMS Air Velocity Sensor Unique dust separating structure, developed by OMRON, in a compact and highly efficient FLOW-SENSOR. Unique dust segregation structure. +/-10% Full-Scale repeatable accuracy achieves
More information1.7. Insulation fault evaluators EDS460/490 EDS461/491
Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 65 35305 Grünberg Tel.: 06401 807-0 Fax: 06401 807-59 Insulation fault evaluators EDS460/490 EDS461/491 Insulation fault evaluators with display and control
More information02/11/2015
MIC48 With RS 485 link Part number 89422418 Heating and / or cooling function 2 independent alarms Load break detection 2 setpoint which can be selected remotely Manual / automatic power adjustment RS
More informationLCP-10G3B4QDRx-G. 10GBASE-LR SFP+ Optical Transceiver FEATURES. Description. Applications. Performance. RoHS compliant
10GBASE-LR SFP+ Optical Transceiver FEATURES RoHS compliant Compliant to SFP+ Electrical MSA SFF-8431 Compliant with SFF-8472 MSA Standard LC duplex fiber-optic connector I 2 C for integrated Digital Optical
More informationSPECIFICATION FOR APPROVAL
SUNON SPECIFICATION FOR APPROVAL CUSTOMER : MOTOR TYPE DESCRIPTION DIMENSIONS M O D E L SUNON SPEC. NO. CUSTOMER APPROVAL NO. APPROVED BY CUSTOMER (AUTHORIZED) : : MagLev Motor Fan : 40X40X20 mm : MF40201VX-1000U-G99
More informationTechnical Data Sheet 1.5mm Side Face Infrared LED
Technical Data Sheet 1.5mm Side Face Infrared LED Features High reliability High radiant intensity Peak wavelength λp=940nm 2.54mm Lead spacing Low forward voltage Pb free This product itself will remain
More informationSUNON SPECIFICATION FOR APPROVAL
SPECIFICATION FOR APPROVAL CUSTOMER : DESCRIPTION : EC AXIAL Fan DIMENSIONS : 120 X 120 X 38 mm M O D E L : CF4113LBL-000U-AA9 SPEC. NO. : A12010180G-00 CUSTOMER APPROVAL NO. : APPROVED BY CUSTOMER : (AUTHORIZED)
More informationECO N DATE DESCRIPTION OF CHANGE CHG
Model Number: M21E-24-DIN Description: The product is a loop powered device which controls an unsupervised dual pole output channel suitable to manage 24VAC loads. The M21E-24-DIN is micro-controller operated,
More informationSTATUS ALARM ALARM HISTORY POWER HISTORY RESET
Instruction Manual Model 1582-70L2 RF Switch June 2011, Rev. D CH1 AUTO CH2 SWITCH 1 2 1 2 STATUS 1 2 MODEL 1582 SWITCH CROSS TECHNOLOGIES INC. CH1 ONLINE MANUAL SELECT CH2 SWITCH MANUAL REMOTE ONLINE
More informationSMART Dust Sensor. Amphenol Advanced Sensors SM-PWM-01C. Application Note. Features
Application Note SMART Dust Sensor SM-PWM-01C SM-PWM-01C dust sensor detects dust particle concentration in air by using an optical sensing method. An infrared light emitting diode (IR LED) and a photo-sensor
More informationFire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63
Fire Extinguishing Control Panel FS5200Е INSTRUCTION MANUAL Revision 8/01.17 Instruction Manual Page 1 1. 2. 3. 4. 4.1. 4.2. 4.2.1. 4.2.2. 4.2.3. 4.2.4. 4.2.5. 4.2.6. 4.2.7. 4.2.8. 4.2.9. 4.2.10. 4.2.11.
More information2 / These specification sheets include materials protected under copyright of Sharp Corporation ("Sharp"). Please handle with great cares and do
2 / 14 1. These specification sheets include materials protected under copyright of Sharp Corporation ("Sharp"). Please handle with great cares and do not reproduce or cause anyone to reproduce them without
More informationPyroelectric Infrared Radial Sensor
Pyroelectric Infrared Radial Sensor TYPE: S16-L201D NANYANG SENBA OPTICAL AND ELECTRONIC CO.,LTD. Page 1 of 9 Mini SMD Digital Pyroelectric Infrared Sensor The product is a digital intelligent PIR sensor.
More informationInstruction VIBROCONTROL 850. Single channel vibration monitor. Keep it accessible for future reference.
Instruction VIBROCONTROL 850 Single channel vibration monitor Keep it accessible for future reference. Copyright 2017 Brüel & Kjaer Vibro GmbH All rights to this technical documentation remain reserved.
More informationENGINEERING SAMPLES PYRO-ELECTRIC IR-DETECTOR
ENGINEERING SAMPLES PYRO-ELECTRIC IR-DETECTOR Customer : Type : PYD 1096 Part no. : engineering samples No. of samples: Dual element detector, serial opposed format, two elements based on pyroceramic.
More informationT.Y.C. BROTHER IND. CO., LTD.
堤維西交通工業股份有限公司 T.Y.C. BROTHER IND. CO., LTD. TEL:+886-6-2658781 ext. 413 FAX:+886-6-2912800 APPLICATION FOR APPROVAL OF A TYPE OF FRONT FOG LAMP ACCORDING TO ECE REGULATION NO. 19-02 SERIES OF AMENDMENTS
More informationUser manual. ABB i-bus EIB. Zone Terminal MT/S Intelligent Installation System ABB STOTZ-KONTAKT
User manual ABB i-bus EIB Zone Terminal MT/S 4.12.1 Intelligent Installation System ABB STOTZ-KONTAKT 2 Contents Page 1 Device configuration..................................... 4 1.1 Introduction..........................................
More informationCM-RQE70A PIR REQUEST TO EXIT DETECTOR
Door Activation Devices CM-RQE70A PIR REQUEST TO EXIT DETECTOR THIS PACKAGE INCLUDES (2) #6 x 3/4" Screws (2) 3/16" Wall Plugs (2) MOV's BP7175 1. GENERAL DESCRIPTION Camden CM-RQE70A Request-to-Exit Sensor
More informationConventional Fire Alarm System 2014 V1.2
Conventional Fire Alarm System 2014 V1.2 Product Overview Control Panel 2 Conventional Fire Panel GST102A 2 zone Fire panel GST104A 4 zone Fire panel GST108A 8 zone Fire panel GST116A 16 zone Fire Panel
More information4) The overcharge detection delay timer reset time function (function for the pulse charge) is provided. 1
MM3280series OUTLINE The MM3511 series are protection IC using high voltage CMOS process for overcharge, overdischarge and overcurrent protection of the rechargeable Lithium-ion or Lithium-polymer battery.
More informationInsulation fault evaluator EDS460-DG
Insulation fault evaluator for localising insulation faults in DC IT systems with a number of branch circuits where high system leakage capacitances are involved Preliminary data sheet TDB108021en/09.2008
More informationEVERLIGHT ELECTRONICS CO.,LTD.
Technical Data Sheet Full Color Top View LEDs Features P-LCC-4 package. White package. Optical indicator. Colorless clear window. Pb-free The product itself will remain within RoHS compliant version. Descriptions
More informationFire Control Panel FS4000
Fire Control Panel FS4000 INSTRUCTION MANUAL Revision 4/02.11 Contents 1. Introduction... 4 2. Terminology... 4 3. Function... 5 4. Technical features... 5 4.1 Fire alarm lines... 5 4.2. Current thresholds
More informationZone Terminal, 2-fold, FM MT/U , GH Q R0111
, GH Q631 0060 R0111 SK 0001 B 01 The zone terminal is used for the monitored connection of detectors from security techlogy on the EIB. The device is installed in conventional switch boxes (Ø 55 mm).
More information2015 Amphenol Advanced Sensors. Jinton Industrial Park, Wujin, Changzhou, Jiangsu, China. Web:
AAS-920-668A Nov., 2015 2015 Amphenol Advanced Sensors Jinton Industrial Park, Wujin, Changzhou, Jiangsu, China Web: www.amphenol-sensors.com Table of Contents 1. Description...................................................................
More informationUser Manual Doc.Ref : JA-KNX-UM. JA-KNX Jablotron KNX Interface ELAUSYS JA-KNX. KNX Interface for Jablotron alarm system.
Page : 1 of 17. ELAUSYS JA-KNX KNX Interface for Jablotron alarm system User Manual Document history Version. Date Author Comment 1.00 24-JUN-2017 NDE First issue 1.01 14-NOV-2017 NDE Support for user
More information7EF/7HF/7EC/7ES Temperature Controllers
7EF/7HF/7E/7ES Temperature ontrollers Dual 4 Digit LED Display Universal Input (6 T/, RTD, mv, V, ma) Autotuning NEMA 4X 100 to 240 Vac Switching Power Supply Algorithms for Heat or Heat/ool ontrol 2 Independent
More informationFIRERAY 5000 range USER GUIDE
FIRERAY 5000 range USER GUIDE 0044-003-04 IMPORTANT PLEASE NOTE: The beam path MUST be kept clear of obstructions at all times! Failure to comply may result in the Detector initiating a Fire or Fault signal.
More informationLa Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual
La Marche Manufacturing Company www.lamarchemfg.com Option 46 Series Digital Combined Accessory Package Installation and Operation Manual This manual is subject to change without notice. You may obtain
More informationOT-FX2 OLED TOUCH for the FX II Touch control panel OPERATOR S MANUAL. Technicold Marine Systems
OT-FX2 OLED TOUCH for the FX II Touch control panel OPERATOR S MANUAL Technicold Marine Systems www.technicold.com Technicold by Northern Lights 1419 W. Newport Center Drive Deerfield Beach, FL 33442 Tel:
More informationGM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /
3 GM20 Digital Ground Continuity Relay For AC Systems Technical Bulletin NAE03230 / 0.20 GM20 Ground continuity monitor For AC systems Description The GM20 monitors the loop resistance of ground conductors
More information1. These specification sheets include materials protected under copyright of Sharp Corporation ("Sharp"). Please handle with great cares and do not re
1. These specification sheets include materials protected under copyright of Sharp Corporation ("Sharp"). Please handle with great cares and do not reproduce or cause anyone to reproduce them without Sharp's
More informationSmart GPS Antenna A1035-D
Smart GPS Antenna A description of Tyco Electronics GPS antenna module User s Manual - PRELIMINARY Version 1.0 Hardware Revision 01 This page was intentionally left blank. Revision History Revision History
More informationSINGLE MONITORED INPUT UNIT BN-303
SINGLE MONITORED INPUT UNIT BN-303 Interactive fire detection system Product Datasheet Features Interactive For interfacing switches and 3rd party detectors with relay outputs to Autronica s interactive
More informationUSER S MANUAL. Profile. MOBILE CALL GSM Alarm System
MOBILE CALL GSM Alarm System USER S MANUAL System disarmed 00/00/00 00:00 ARM STAY CALL 1 2 3 4 5 6 7 8 9 Power Set Signal Alarm SOS ESC 0 ENTER Profile For a better understanding of this product, please
More informationRC802/ B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual
RC802/804-240B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual Raisecom Technology Co., Ltd. (04/2005) 1. Cautions Please read the following notices carefully before installing and using the device,
More informationRS Pro Infrared Temperature Sensor
Instruction Manual RS Pro Infrared Temperature Sensor Stock Number: 161-8103 Introduction The RS Pro Infrared Temperature Sensor is a device for measuring the temperature of the surface of a solid or liquid
More informationDS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel
DS3MX-E-I EN Installation Guide 3 Mini Control Panel DS3MX-E-I Installation Guide 1.0 General Information EN 2 1.0 General Information The DS3MX is a three zone mini control panel, which can be installed
More informationDS1486/DS1486P RAMified Watchdog Timekeepers
RAMified Watchdog Timekeepers www.maxim-ic.com FEATURES 128 kbytes of User NV RAM Integrated NV SRAM, Real-Time Clock, Crystal, Power-Fail Control Circuit and Lithium Energy Source Totally Nonvolatile
More informationMagnetoresistive Sensor ICs. Nanopower Series. Datasheet
Magnetoresistive Sensor ICs Nanopower Series Datasheet Magnetoresistive Sensor ICs Honeywell s Nanopower Series Magnetoresistive (MR) Sensor ICs are ultra-sensitive devices designed to accommodate a wide
More information200 SERIES ADVANCED PHOTO/THERMAL/IR DETECTOR PRODUCT SPECIFICATION
GENERAL DESCRIPTION This product is the photo/thermal/ir variant of 2 Series Advanced, the redesigned 2 Series all SMD adopting the new chamber and a new style of covers. It works with the 2 Series extended
More informationTechnical Data Sheet 3mm Phototransistor T-1
Technical Data Sheet 3mm Phototransistor T-1 Features Fast response time High photo sensitivity Pb free The product itself will remain within RoHS compliant version. PT24-6C Descriptions PT24-6C is a high
More informationGas Safety Products. Installation, operating and maintenance 09/05/2016. Merlin CT1650+ Gas Interlock System. S&S Northern Ltd 1
Gas Safety Products Merlin CT1650+ Gas Interlock System Installation, operating and maintenance 09/05/2016 S&S Northern Ltd 1 Table of contents 1 General information... 3 2 Installation... 3 2.1 Panel
More informationInstruction Manual Model L2 RF Switch
Instruction Manual Model 1582-22L2 RF Switch November 2015, Rev. A CH1 AUTO CH2 SWITCH 1 2 1 2 STATUS 1 2 MODEL 1582 SWITCH CROSS TECHNOLOGIES INC. CH1 ONLINE MANUAL SELECT CH2 SWITCH MANUAL REMOTE ONLINE
More informationReflective Optical Beam Smoke Detector User Guide
Reflective Optical Beam Smoke Detector User Guide 1. Installation IMPORTANT NOTE: The infrared beam path MUST be kept clear of obstructions at all times! Failure to comply may result in the system initiating
More informationSUNON SPECIFICATION FOR APPROVAL
SPECIFICATION FOR APPROVAL CUSTOMER : DESCRIPTION DIMENSIONS M O D E L P/N SUNON SPEC. NO. CUSTOMER APPROVAL NO. APPROVED BY CUSTOMER (AUTHORIZED) : AXIAL AC FAN : 120X120X38 mm : DP200A : 2123XST.GN :
More informationARROWHEAD ALARM PRODUCTS Ltd. 344b Rosedale Rd, Albany, Auckland. Ph Fax v1.0
ARROWHEAD ALARM PRODUCTS Ltd. 344b Rosedale Rd, Albany, Auckland. Ph. 09 414 0085 Fax. 09 414 0088 www.aap.co.nz v1.0 Zone Trouble Shooting (single EOL) = = = = RED, RED, RED, GOLD. = YELLOW, VIOLET, RED,
More informationISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances
ISOSCAN Insulation fault locator for DC IT systems with high system leakage capacitances _D00108_00_D_XXEN/05.2015 ISOSCAN Insulation fault locator for DC IT systems with high system leakage capacitances
More informationWIO200 Water In Oil measuring instrument
WIO200 Water In Oil measuring instrument You have made the right decision by choosing a measuring instrument from PAJ Systemteknik. Many customers buy our high standard products every year. There are at
More informationStandard SPECIFICATIONS FEATURES APPLICATIONS
SPECIFICATIONS PC Board Mountable Pressure Sensor 0-50 mv Output Voltage Excitation Gage, Absolute, and Differential Temperature Compensated FEATURES Dual-in-Line Package 0ºC to 50ºC Compensated Temperature
More informationDual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual
We manage heat MANUAL Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202 or (800) 234-4239
More informationIMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!
USER GUIDE English IMPORTANT PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times! Failure to comply may result in the Detector initiating a Fire or Fault signal. Contents
More informationNIDS Dust sensor ED-N-DS-1408
SPECIFICATION (Tentative) Product Name: Dust Sensor(High Sensitivity) Model No. : SM-PWM-01A-HS SMART dust sensor for air purifier SM-PWM-01A-HS Description SM-PWM-01A-HS is a dust sensor that detects
More information02/11/2015
CTH 46 - CTD 43 / 46 CTD 46 Part number 89422108 CTH 46 Heating / cooling function Measurement and setpoint display CTD 43 Heating or cooling function Measurement display Measurement deviation display-setpoint
More informationS INTRUSION&FIRE ALARM AND ACCESS CONTROL PANEL
S2000-4 INTRUSION&FIRE ALARM AND ACCESS CONTROL PANEL Installer s and User s manual S2000-4 INTRUSION&FIRE AND ACCEESS CONTROL PANEL ATTENTION! To modify configuration parameters use the program uprog.exe
More informationFPX103C Auto DUAL LOOP AUTO/MANUAL FIRE CONTROL PANEL Iss 1.0
FPX103C Auto DUAL LOOP AUTO/MANUAL FIRE CONTROL PANEL Iss 1.0 SUMMARY: Dual detection loops with full fault monitoring. Automatic extinguisher operation after shutdown. Double knock automatic activation
More information