SCAN STEERING Excellent Navigation

Size: px
Start display at page:

Download "SCAN STEERING Excellent Navigation"

Transcription

1 SCAN STEERING Excellent Navigation

2 AS SCAN AS SCAN is a modern and high tech engineering company with 0 highly qualified employees. AS SCAN has extensive experience in steel structures, engine and hydraulic installations, and deliveries to the Navy, offshore, district heating sector and the wind industry. The company has a C machines with CAD / CAM systems. AS SCAN Hvide Sande was established in 0 and functioned as a supplier of technical solutions as the fishing industry was at its highest in Denmark. After the decline in the fishery, the subsequent development of the quota system and the development of fisheries as an effective industrial unit with fewer and larger vessels, we decided to focus on other types of ships and energy solutions to the industry. AS SCAN evolved from being a local fishing gear provider to become an export oriented company with several products for various industries and markets worldwide. Scan Steering Scan Steering was founded in 0, but taken over by AS SCAN back in 004. Today Scan Steering is one of the leading manufacturers of complete steering systems, for several types of vessels in the world. Scan Steering has always been ahead of their competitors when it comes to developing new technology and complete steering systems. Dealing with only one supplier benefits our customers in several ways. Today s modern vessels require steering systems with an absolute minimum of maintenance needs. Quality and safety comes first and with more than 0 years of experience in installing steering systems for a wide variety of vessels Scan Steering has become a lead player on the market. The Scan Steering systems are made for one, two or more rudders and the multi rudder systems can be electronic or mechanical synchronized. All steering systems of Scan Steering are made according to IMO, SOLAS and build to fit the restrictions of any classification authority. Scan Steering will continuously work on improvements in quality and performance of all parts of the steering gear system in order to keep ahead of our competitors.

3 Steering gear Steering gear sizes TM The range of Scan Steering is from 0. ton/meters to 00 ton/meters and can be installed on all types of vessels. The steering gear is suitable for one, two or more rudders, either with connection bar or electrical synchronizing. The steering gears main parts are as following: Power Pack, Base Plate, with support bearing, Cylinders, Tiller with keyway, Valve Block and all necessary valves, fittings and flexible hoses. Compact installations The steering gear installations are often very compressed, but as Scan Steering is an extremely flexible company we customize our standard models to match the space available. For us, the customer s requirements are the most important issue and we always try to meet the demands we are faced with. Special vessels At Scan Steering we always accept the challenge and this applies irrespective of its design and use. It often means that the series is only on one ship, but it is our production designed for and therefore we can still deliver at competitive prices.

4 Power Packs & Starters MS Single motorstarter for on electro-hydraulic pump units. Complete with amp.meter and emergency stop. Alarms for: Start/stop Test Power failure Low oil Overload PSU Single Power Pack Single pump unit. Electrical motors squirrel cage type. Current and frequency according to customer s requirement. IP protection, insulation class F, included in the hydraulic tank and homologous accessories, such as gauge glasses, low oil level switch, temperature- and pressure switches, valves and fittings. Electrical motor is to drive one gear wheel pump through an elastic coupling. Pump units can be ordered with lock alarm and class certificate from any classification society. PSU Double Power Pack Dual pump unit. Build on double tank, separated by internal wall. Two identical electrical motors squirrel cage type. Current and frequency according to customer s requirement. IP protection, insulation class F, included in the hydraulic tank and homologous accessories, such as gauge glasses, low oil level switch, temperature- and pressure switches, valves and fittings. Each motor is to drive one gear wheel pump through an elastic coupling. Pump units can be ordered with lock alarm and class certificate from any classification society.

5 Rudder Control & Starters MR 00 / MR 00 Remote control for MS- / MS- motorstarter. For mounting on bridge. Alarms for: Start/stop Test Power failure Low oil Overload Alarmlock RC/MS Double remote control for RC (rudder control) and MS- (motorstarter). Joystick for non-follow-up and rudder indicator. Facilities for connection of additional rudder indicator and Full-follow-up. Alarms for: Start/stop Test Power failure Low oil Overload RC Double rudder control with two electrical separated systems for electrical steering and control of up to 4 sets of hydraulic valves. Each system consist of: Rudder indicator Switch for bridge/steering room control Non-follow-up control of the rudder

6 Universal Repeaters DE-0 Digital repeater operates on NMEA 0 (RS4 or RS). DE-00 Digtal repeater/turning indicator can oper- ate on NMEA 0 (RS4 or RS), step by step and syncro 0: input. The bar graph showing rate of turn. GFC Azimuth circle for bearing repeater. Delivered in wooden box. 4 4 BRA-0 Steering repeater with tilting bracket. Operates on NMEA 0 (RS4 or RS), step by step. BRB-0 Bearing repeater for bulk- head mounting. Facilities for Azimuth Operates on NMEA 0 (RS4 or RS), step by step. 0 0

7 Accessory Equipment BRC-0 Bearing repeater on column. Facilities for Azimuth. Operates on NMEA 0 (RS4 or RS), step by step. FBP Electronic rudder angle transmitter with single or double signal. Delivered with longlife potentiometer. Improved version with high accuracy. RVP- Panorama rudder indicator, with dimmer. Improved version. FU S-M40 Full Follow Up with wheel. Green backlight. Size: x mm V-00m Watch alarm with switch for 0 or minutes delayed alarm. STM / STU STM: Manuel pilot operation. STU: Joystick control. FFU-000 Full Follow Up with wheel. Adjustable zero and gain. 4 4 STS Joystick With push button to activate steering position. RXL Ground-breaking range of panelmounted illuminated rudder indicators. Size: x mm and x mm. NFU Hand operated non-follow-up with rudder indicator and m wire.

8 Examples of Steering System driven by main engine Steering gear with two electrical pumps

9 complete steering systems Steering gear with mechanical connection bar Electronical synchronized steering gear

10 Wiring Diagrams MR00LA X common lamp/buzzer common lamp/buzzer X X +V Hydraulic alarm lamp +V Hydraulic alarm lamp X X +V Hydraulic alarm buzzer +V Hydraulic alarm buzzer X ST reset reset ST W x0,#s ST4 Reset Reset ST4 W x0,#s DC Supply alarm DC Supply alarm Buzzer Buzzer 4 Power on Power on 4 Power fail alarm Power fail alarm Over load alarm Over load alarm Test Test Power fail ack. Power fail ack. Over load ack. Over load ack. 0 +4V +4V 0 Low oil ack. Low oil ack. Start Start Stop Stop 4 Low oil alarm Low oil alarm 4 Start indicator Start indicator Stop indicator Stop indicator Dimmer Dimmer W x0,#s +V +V W4 x0,#s Remote panel f. motorstarter, HL00 remote Cable route A Cable route B MS DC Supply alarm Buzzer 4 Power on Power fail alarm Over load alarm Test Power fail ack. Over load ack. 0 +4V Low oil ack. Start Stop 4 Low oil alarm Start indicator Stop indicator Dimmer +V Connection for remote panel I (RCMS / MR00 / MR00 / MR00-LA) Connection for remote panel II (RCMS / MR00 / MR00 / MR00-LA) DC Supply alarm Buzzer Power on 4 Power fail alarm Over load alarm Test Power fail ack. Over load ack. +4V 0 Low oil ack. Start Stop Low oil alarm 4 Start indicator Stop indicator Dimmer +V DC supply A (0Amp) +0..+V AC supply A (x 0Amp 0Hz) L L L W x,#s W x,#s +4V /GND DC Supply I Oil-Level common Oil-Level common W x0,#s 4 Oil-Level, OK= Oil-Level, OK= 4 W x0,#s L L L Phase Phase Phase AC Supply I Float Sensor I W x,#s W0 x,#s Danger Float Sensor II DC Supply II AC Supply II +4V /GND Phase L Phase L Phase L Danger DC supply B (0Amp) +0..+V AC supply B (x 0Amp 0Hz ) L L L U Phase Phase U Hi Voltage V Phase Phase V Phase Potentiale free contacts I Potentiale free contacts II W Hi Voltage W x,#s W W x,#s Phase (used for other equipment than Scan-Steering) (used for other equipment than Scan-Steering) Phase Motor I Phase Motor II RL Status: Start RL Status: Start RL Status: Stop RL Status: Stop RL Alarm: Low oil RL Alarm: Low oil RL4 Alarm: Over load RL4 Alarm: Over load RL Alarm: Phase fail RL Alarm: Phase fail RL Alarm: Power.fail RL Alarm: Power.fail RL Status: Start RL Status: Start RL Status: Stop RL Status: Stop RL Alarm: Low oil RL Alarm: Low oil RL4 Alarm: Over load RL4 Alarm: Over load RL Alarm: Phase fail RL Alarm: Phase fail RL Alarm: Power.fail RL Alarm: Power.fail Earth PE Double motorstarter X x0,#s X x0,#s Earth Alarm panel etc. Alarm panel etc. H-PSU Oil filter I_page_A U Phase Phase U V Phase Phase V W Phase Phase W W x0,#s W4 x0,#s Phase Motor I Oil-filter common (OK=) NO (Fail=) Oil-filter sensor I W x0,#s ()- Oil-Level common Oil-Level common -() W x0,#s (4)- Oil temp I_page_A Oil-Level, OK= Oil-Level, OK= -(4) Oil-Temp. common Oil-Temp. common Oil temp II_page_4A 4 Oil-Temp. OK= Oil-Temp. OK= 4 Float Sensor I VDR etc. High RS4 data Hi out RS4 data Hi out High VDR etc. Low RS4 data Lo out RS4 data Lo out Low X lamp/buzzer lamp/buzzer X X Hydraulic alarm lamp Hydraulic alarm lamp X X Hydraulic alarm buzzer Hydraulic alarm buzzer X W x,#s ST reset reset ST ST4 Solenoid I_page_G Reset Reset ST4 Not connected! StBd StBd 0 +4V common 0 W x,#s +4V common Port Port StBd StBd X x0,#s 0 +4V common 0 X x0,#s +4V common Alarm panel etc. Port Port RL Alarm common Alarm common RL Alarm panel etc. RL Alarm NO Alarm NO RL +0..+V +4V +4V Supply +4V Supply +4V DC supply A (0Amp) W x,#s Supply Supply W0 x,#s HL00 I Oil-filter sensor II Float Sensor II HL00 II Phase Motor II Oil-filter common (OK=) NO (Fail=) X x0,#stp X4 x0,#stp Oil filter II_page_4A +0..+V DC supply B (0Amp) Earth x hydraulic pumps, HL00 Earth Symbol explanation: / All cabels must be of shielded and approved type. Scan-Steering 0--0 Date: Sheet: of Size: A

11 - - 4 Wiring Diagrams /GND pwr +4V pwr 0-V FB in /GND FB - Dimmer /GND Dim. RXL_ /GND pwr +4V pwr 0-V FB in /GND FB - Dimmer /GND Dim. RXL_ /GND pwr +4V pwr 0-V FB in /GND FB - Dimmer /GND Dim. G O G O C RXL_ (-/)- (+/)- (F/)- (G/)-4 (+/)- (-/)- Rudder angle indicator Illumination power supply in (-/)- (+/)- (F/)- (G/)-4 (+/)- (-/)- Rudder angle indicator Illumination power supply in (-/)- (+/)- (F/)- (G/)-4 (+/)- (-/)- Rudder angle indicator Illumination power supply in FFU000 STU_ RE400 STU_ StBb NO Port NO NFU joystisk Lo out Hi out Lo in Hi in /GND pwr +4V pwr Remote control for ELxxx A B +V - Signal Full follow up steering wheel StBb NO Port NO NFU joystisk W 4x0,#s W 4x0,#s W 4x0,#s Junction terminals not supplied by SS! located inside desk console etc. W x0,#s W4 4x0,#s W x0,#s Junction terminals not supplied by SS! located inside desk console etc. W x0,#s W x0,#s W NFU_ W NFU_ W x0,#s EL00 +V A - Signal B C Select = D E NO F NFU Select = StBd = Port = NO 0 Lo in Hi in Lo out Hi out 4 /GND pwr +4V pwr 0-V FB +V +4V +V A - Signal B C NFU Select = StBd = Port = +V A - Signal B C Select = D E NO F NFU Select = StBd = Port = NO 0 FFU I NFU I Remote panel Rudder A/B indicator FFU Master NFU Master (always showing master system) (initially selected when RE400 changeover) FFU II NFU II NOT Scan-Steering! - 4 volt DC command StBd Port command ON=Auto selected Auto pilot example 4 X x0,#s Potentiale free contact: Closed circuit = Start-signal to auto-pilot 4 StBd = +4V StBd = Port = +4V Port = Auto Select= NO (auto=closed) 0-V FB +V +4V Autopilot A (Optocoupler input -4) Rudder A indicator (Optocoupler input -4) Autopilot B Rudder B indicator StBd = +4V StBd = Port = +4V Port = 4 Auto Select= NO (auto=closed) 0-V FB +V +4V W x0,#s E F +V FB sig. G Feedback A Feedback B +V E FB sig. F G W0 x0,#s DC supply A Alarm A PSU I PSU II Alarm B DC supply B + /GND +4V NO StBd 0 +4V common 0 +4V common Port StBd 0 +4V common 0 +4V common Port NO + /GND +4V Earth PE Rudder controller Earth W x,#s X x0,#s W x,#s LIMIT SWITCH X x0,#s DC supply A (0Amp) +0..+V Alarm panel etc. i StBd in StBd out o 0 i +4V common in +4V common out 0 o i Port in Port out o Solenoid I_Page_G Alarm panel etc. DC supply B (0Amp) +0..+V W4 x,#s Physical limit switch FBP Double rudder feedback unit A E F +V FB Sig. Earth B E F +V FB Sig. Earth Symbol explanation: / All cabels must be of shielded and approved type. Scan-Steering 0--0 Date: Sheet: of Size: A

12 Fabriksvej 4 - DK - 0 HVIDE SANDE TLF: TELEFAX: +4 w w w.as - scan.com - - scan.com

Technical Data Sheet BNWAS. Bridge Navigational Watch Alarm System. Technical Data Sheet. General Features

Technical Data Sheet BNWAS. Bridge Navigational Watch Alarm System. Technical Data Sheet. General Features Technical Data Sheet BNWAS Bridge Navigational Watch Alarm System Technical Data Sheet General Features Technical Data Sheet Bridge Navigational Watch Alarm System (BNWAS) New SOLAS regulations require

More information

Manual. Simrad Panorama Mk2 Rudder Angle Indicator. English. A brand by Navico - Leader in Marine Electronics.

Manual. Simrad Panorama Mk2 Rudder Angle Indicator. English. A brand by Navico - Leader in Marine Electronics. Manual Simrad Panorama Mk2 Rudder Angle Indicator English www.simrad-yachting.com A brand by Navico - Leader in Marine Electronics Manual Simrad Panorama Mk2 Rudder Angle Indicator English Document no:

More information

Digital Marine Exhaust Temperature Alarm

Digital Marine Exhaust Temperature Alarm Digital Marine Exhaust Temperature Alarm Model: SM007D/S INTRODUCTION COMPONENTS Marine water cooled exhaust systems are designed to withstand temperatures of up to about 120 C. However the exhaust gases

More information

operating device LOD , 144x72mm designed for retrofit

operating device LOD , 144x72mm designed for retrofit BNWAS le guardian 225 sm electrics operating device LOD 2.24.., 44x72mm designed for retrofit connecting module LCM 2.24.. over 5 installations easy and comfortable use simple connections to all peripheral

More information

INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000.

INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000. INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3 M336 Rev F November 21, 2000 ÇConsilium Consilium US, Inc. 59 Porter Rd Littleton, MA 01460-1431 USA

More information

CARGO PUMP CONTROL & MONITORING SYSTEM

CARGO PUMP CONTROL & MONITORING SYSTEM TR-MARINE / CARGO WATCH II v.02 OPERATION AND MAINTENANCE MANUAL CARGO PUMP CONTROL & MONITORING SYSTEM PROJECT REF NO : TRM-CWII/G48 SHIYARD : GISAN HULL NO : NB48 Page 1 / 73 1. 2. 3. 4. 5. TABLEOFCONTENTS

More information

M1000 Alarm Annunciator

M1000 Alarm Annunciator Data Sheet Alarm Annunciator Reliable Supervision and Control 10 inputs with LED indications Supports both NO/NC input contacts 10 open collector outputs Built-in siren relay Text label for alarm descriptions

More information

CPX MEDICAL AIR PLANT INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

CPX MEDICAL AIR PLANT INSTALLATION, OPERATIONS & MAINTENANCE MANUAL CPX MEDICAL AIR PLANT INSTALLATION, OPERATIONS & MAINTENANCE MANUAL Company Registered Office: Crown House, Stockport, Cheshire, SK13RB No. 850 Registered in England and Wales No. 05058855 VAT VERSION

More information

Swan Song. Engine Rooms

Swan Song. Engine Rooms Engine Rooms The two main engines are Yanmar 6LYA STP rated at 350hp at 3300 rpm. They are continuously rated at 290hp at 3100 rpm and she will cruise at 24 knots at this speed. Maintenance is as per the

More information

Pump-Down Controller MODEL 4052

Pump-Down Controller MODEL 4052 Pump-Down Controller 4-20mA Input/Scalable Output Seal Fail Monitoring Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters RS-485/Modbus Communications DESCRIPTION The Model 4052 Pump-Down

More information

WELCOME. The human touch in technology. marine

WELCOME. The human touch in technology. marine WELCOME The human touch in technology ALPHATRON MARINE IS SPECIALIZED IN THE FOLLOWING AREAS: ALPHATRON MARINE COMMUNICATION The human touch in technology TELEPHONE EXCHANGE (PABX) PUBLIC ADDRES SYSTEMS

More information

Original user manual. Body Drum. page 1 of 35. Jasopels Fabriksvej 19 Sales: tel Fax: Service: tel.

Original user manual. Body Drum. page 1 of 35. Jasopels Fabriksvej 19 Sales: tel Fax: Service: tel. Original user manual Body Drum page 1 of 35 1. Declaration of Conformity EU Declaration of Conformity Manufacturer: Jasopels A / S Tel. +45 76 94 35 00 Address: Fabriksvej 19, DK-7441 Boarding Machine:

More information

Pump-Up Controller MODEL 4062

Pump-Up Controller MODEL 4062 Pump-Up Controller 4-20mA Input/Scalable Output Seal Fail Monitoring Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters RS-485/Modbus Communications DESCRIPTION The Model 4062 Pump-Up

More information

MiLAB Oxygen Control MANUAL & INSTALLATION. MOC-100 Ver 3.0

MiLAB Oxygen Control MANUAL & INSTALLATION. MOC-100 Ver 3.0 MiLAB Oxygen Control MANUAL & INSTALLATION MOC-100 Ver 3.0 Contents 1 INTRODUCTION...3 2 FUNCTIONS...4 2.1 O 2 REGULATION...4 2.2 DISPLAY BOARD...4 2.3 COMMUNICATION THROUGH PANEL...5 2.3.1 Set parameters...5

More information

Gas Safety Products. Installation, operating and maintenance. Merlin 1000BH Gas Proving/Gas Detection System

Gas Safety Products. Installation, operating and maintenance. Merlin 1000BH Gas Proving/Gas Detection System Gas Safety Products Merlin 1000BH Gas Proving/Gas Detection System Installation, operating and maintenance Read these instructions carefully before operating or servicing Rev: 05 Date: 08-01-18 1 Table

More information

PARTS LIST ALPHABETICAL ALL FROSTY FACTORY MODELS Rev 06/12/2014 Description Item No. Used on models Price Bearing, Flywheel F ,137,215, 232,

PARTS LIST ALPHABETICAL ALL FROSTY FACTORY MODELS Rev 06/12/2014 Description Item No. Used on models Price Bearing, Flywheel F ,137,215, 232, PARTS LIST ALPHABETICAL ALL FROSTY FACTORY MODELS Rev 06/12/2014 Description Item No. Used on models Price Bearing, Flywheel F0267 115,137,215, 232, 237 43.15 Bearing, Motor,Frt.Coupling F0427 113,117,127,217

More information

ELECTROPROJECT GTV-A POWER SUPPLY FOR DOOR MAGNETS

ELECTROPROJECT GTV-A POWER SUPPLY FOR DOOR MAGNETS ELECTROPROJECT POWER SUPPLY FOR DOOR MAGNETS Innovative and carefully thought out Always the right drive ELECTROPROJECT AANDRIJFTECHNIEK ElectroProject has evolved over the last 75 years from a technical

More information

1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1 ANSI/NFPA 20, Centrifugal Fire Pumps.

1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1 ANSI/NFPA 20, Centrifugal Fire Pumps. Issued 2006/08/01 Section 13920 Packaged Fire Pumps and Controllers Page 1 of 7 PART 1 GENERAL 1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1

More information

DEIF A/S. Operator s Manual. Basic Gen-set Controller. Display readings. Push-button functions. Alarm handling. Log list C (UK)

DEIF A/S. Operator s Manual. Basic Gen-set Controller. Display readings. Push-button functions. Alarm handling. Log list C (UK) Basic Gen-set Controller 4189340315C (UK) Display readings Push-button functions Alarm handling Log list DEIF A/S DEIF A/S, Frisenborgvej 33 Tel.: +45 9614 9614, Fax: +45 9614 9615 DK-7800 Skive, Denmark

More information

Electronic Emergency Telegraph. TG-1 and TG-1A

Electronic Emergency Telegraph. TG-1 and TG-1A Electronic Emergency Telegraph modification level Version Date Author Approved Remarks 01 23.10.2012 STO TK 1st issue Page: 1 TABLE OF CONTENTS 1. IMPORTANT SAFETY INSTRUCTIONS 3 1.1. QUALIFIED PERSONNEL

More information

S/601 Controller Installation Manual

S/601 Controller Installation Manual Checked Version Release date QA V4.6.5 PC1 EN 02.07.2012 2011 S/601 Controller Installation Manual FLOW CONTROL PC1 - Pump controller Introduction Thank you for using the S/601 flow, batch and pump control

More information

Damcos SPU - General System Power Unit

Damcos SPU - General System Power Unit Product Data Sheet Damcos SPU - General System Power Unit Damcos SPU Product Data Sheet Advantages - Major class authority approvals - Multiple redundancy functions - Flexible PLC control - Serviceable

More information

Installation Instructions CS3 Three Phase Solid State Relay

Installation Instructions CS3 Three Phase Solid State Relay Installation Instructions CS3 Three Phase Solid State elay 1 PK522-3 0037-75550 March 2018 Important Safeguards HIGH VOLTAGE is used in the operation of this equipment; DEATH ON CONTACT may result if personnel

More information

Technical Manual. Level Alarm Unit CARLA & WIDS

Technical Manual. Level Alarm Unit CARLA & WIDS CARLA & WIDS Technical Manual SAS au Capital de 2 158 244-444 871 933 R.C.S. Bourges - APE : 2651B Headquarter : 9, rue Isaac Newton - 18000 Bourges - France Technical Manual CARLA for Tankers Cargo Tanks

More information

TQ4400 TANKSCAN GAS SAMPLING SYSTEM OPERATING MANUAL

TQ4400 TANKSCAN GAS SAMPLING SYSTEM OPERATING MANUAL TQ4400 TANKSCAN GAS SAMPLING SYSTEM OPERATING MANUAL TQ Environmental Plc July 2009 This manual must not be copied or reproduced in part without the express written permission of TQ Environmental PLC.

More information

BR

BR BR-500 www.furuno.com Monitor watch officer's presence and receive early warning detections in case of an emergency Flash Beacon Watertight Motion Detector Meets the IMO resolution MSC.128(75) for Bridge

More information

FIRERAY 5000 range USER GUIDE

FIRERAY 5000 range USER GUIDE FIRERAY 5000 range USER GUIDE 0044-003-04 IMPORTANT PLEASE NOTE: The beam path MUST be kept clear of obstructions at all times! Failure to comply may result in the Detector initiating a Fire or Fault signal.

More information

Explosion-Proof Forced Air Unit Heater - XGB

Explosion-Proof Forced Air Unit Heater - XGB Explosion-Proof Forced Air Unit Heater - XGB The XGB Series hazardous environment heater is designed to accommodate your requirements with flexibility and ease of maintenance, even under the toughest conditions.

More information

Operating Instructions

Operating Instructions Operating instructions BAK Hose extruder HS28 BAK Thermoplastic Welding Technology AG Operating Instructions HSX001 Hose extruder HS28 BAK Thermoplastic Welding Technology AG Operating instructions BAK

More information

US$ 350 for a single warranty claim

US$ 350 for a single warranty claim MAKING MODERN LIVING POSSIBLE A pressure transmitter overview Protect market reputation Minimise warranty costs US$ 35 for a single warranty claim was adding up quickly for one of our customers, which

More information

XGB Unit Heater. Certification. Model Coding XGB 038 T3B 3 1 T TEMPERATURE CODE T3B (165 C) T3A (180 C) T2D (215 C) T2C (230 C)

XGB Unit Heater. Certification. Model Coding XGB 038 T3B 3 1 T TEMPERATURE CODE T3B (165 C) T3A (180 C) T2D (215 C) T2C (230 C) The Norseman Series hazardous environment heater is designed to accommodate your requirements with flexibility and ease of maintenance, even under the toughest conditions. Norseman unit heaters are available

More information

SPECIFICATIONS. HCA131A-High Accuracy 4 directions Control Switch(Switch Output) Item No.:HCA131A

SPECIFICATIONS. HCA131A-High Accuracy 4 directions Control Switch(Switch Output) Item No.:HCA131A SPECIFICATIONS Item No.:HCA131A Description:High Accuracy 4 directions Control Switch(Switch Output) Version:Ver.05 General Description HCA131A is a full temperature high accuracy 4-Axis level control

More information

COMPANY PROFILE. Design, Development & Installation of Electrical & Automatic Control Systems

COMPANY PROFILE. Design, Development & Installation of Electrical & Automatic Control Systems COMPANY PROFILE Design, Development & Installation of Electrical & Automatic Control Systems MSB/ESB Main & Emergency Switchboards PMS Power Management Systems Engine Room Alarm Monitoring Systems Engine

More information

Explosion-Proof Forced Air Unit Heater - XGB

Explosion-Proof Forced Air Unit Heater - XGB Explosion-Proof Forced Air Unit Heater - XGB The XGB Series hazardous environment heater is designed to accommodate your requirements with flexibility and ease of maintenance, even under the toughest conditions.

More information

Syncro Matrix Analogue Addressable Fire Alarm Mimic Panel Product Manual

Syncro Matrix Analogue Addressable Fire Alarm Mimic Panel Product Manual Syncro Matrix Analogue Addressable Fire Alarm Mimic Panel Product Manual Australia Issue 01 April 2012 Contents 1 Introduction 3 2 Safety 3 3 Installation 4 3.1 Mounting the Cabinet 4 4 Specifications

More information

Gas Safety Products. Installation, operating and maintenance 23/08/2016. Merlin 1000BH Gas Proving/Gas Detection System

Gas Safety Products. Installation, operating and maintenance 23/08/2016. Merlin 1000BH Gas Proving/Gas Detection System Gas Safety Products Merlin 1000BH Gas Proving/Gas Detection System Installation, operating and maintenance 23/08/2016 S&S Northern Ltd 1 Table of contents 1 General information... 3 2 Installation... 3

More information

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes 50-120 1 General The heat exchanger control system is a control system for 380 W step motors

More information

Item Number Description Price. Accessories " Diesel/Water/Waste tank sender $ Battery temperature sensor $2.22

Item Number Description Price. Accessories  Diesel/Water/Waste tank sender $ Battery temperature sensor $2.22 DIGITAL Vessel Monitoring 1800 Monitor Monitor includes head unit, surface mount bezel, surface mount gasket, DC current shunt 8255, AC current transformer 8256, battery temperature sensor 1820, connectors,

More information

DIESEL Engine Fire Pump Controllers Features

DIESEL Engine Fire Pump Controllers Features September 007 DIESEL Engine Fire Pump Controllers Features FD0 Diesel Engine Controllers 1-1 Printer / Recorder The industrial grade thermal printer is housed in a rugged steel enclosure within the controller.

More information

Distributed By: M&M Control Service, Inc Building Technologies

Distributed By: M&M Control Service, Inc Building Technologies Building Technologies Combustion Control Systems Count on Siemens. Siemens Building Technologies, the worldwide industry leader in combustion controls, delivers globally approved products specifically

More information

Centro-Matic Automated Lubrication Systems System Controls

Centro-Matic Automated Lubrication Systems System Controls Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the

More information

TT /97. Features INSTALLATION INSTRUCTIONS. Horn. Lamps

TT /97. Features INSTALLATION INSTRUCTIONS. Horn. Lamps TT-1023 1/97 INSTALLATION INSTRUCTIONS Original Issue Date: 2/94 Model: 6-2000 kw Market: Industrial Subject: Flush- or Surface-Mount Remote Annunciator Kits PA-293991 and PA-293991-SD The remote annunciator

More information

Notice No. 7. Rules and Regulations for the Classification of Ships, July Issue date: March Working together for a safer world

Notice No. 7. Rules and Regulations for the Classification of Ships, July Issue date: March Working together for a safer world Notice No. 7 Rules and Regulations for the Classification of Ships, July 2014 The status of this Rule set is amended as shown and is now to be read in conjunction with this and prior Notices. Any corrigenda

More information

LEAKSTOPPER MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND OPERATION MANUAL

LEAKSTOPPER MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND OPERATION MANUAL LEAKSTOPPER MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND OPERATION MANUAL The LeakStopper Multizone detects the presence of water in environments where it is not supposed to be. Should water

More information

FLOW CONTROLLER TYPE S/601

FLOW CONTROLLER TYPE S/601 Checked Version Release date QA V4.2.6 F1 F2 EN 26.01.2012 Manual FLOW CONTROL FLOW CONTROLLER TYPE S/601 MODELS F1 AND F2 INTRODUCTION Thank you for using the S/601 flow and batch control series. This

More information

FR-A180 FR-A360. Occupancy detector. Use

FR-A180 FR-A360. Occupancy detector. Use 5 488 Occupancy detector with daylight sensor Occupancy detector with integral daylight sensor for demand-based control of HVAC systems and lighting. Adjustable switch-on and switch-off delay Adjustable

More information

Intelligent Lighting Controller

Intelligent Lighting Controller Intelligent Lighting Controller Model: ILC- 4ch Intelligent Lighting Controller (ILC-4ch) is an electronic controller designed specifically to operate the lighting circuits used in homebuilt aircraft.

More information

Electro-Sentry. Users Manual

Electro-Sentry. Users Manual Electro-Sentry Users Manual 2. To view an individual point, e.g. Speed just touch that point and it will display a graph showing the 45 min. of activity. Viewing a Leg: 1. Touch the desired leg, e.g. East

More information

Remote Vacuum Sensor and Variable Speed Vacuum Pump Control Manual. Version Date - June Part Number

Remote Vacuum Sensor and Variable Speed Vacuum Pump Control Manual. Version Date - June Part Number Innovation In and Out of Parlour Remote Vacuum Sensor and Variable Speed Vacuum Pump Control Manual Version - 1.0 Date - June 2016 Part Number - 39-0038 Index Manual Version... 3 About the Remote Vacuum

More information

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge Replaceable LED modules 11 Alarm Sequences as per ISA-18.1 standard Each channel/window fully field programmable RS232 or RS485 MODBUS-RTU communication Repeat relay for each window and multifunction relays

More information

Process Alarm Solutions

Process Alarm Solutions Process Alarm Solutions Reliable Supervision and Control» Control. Monitor. Protect. SELCO Flexible alarm panels for supervision and control SELCO provides efficient and reliable solutions for alarm monitoring

More information

Section - III SYSTEMS DESCRIPTION

Section - III SYSTEMS DESCRIPTION Section - III SYSTEMS DESCRIPTION Pro Line 21 Table of Contents Page GENERAL...1-3 ANNUNCIATOR TYPES...1-3 ARRANGEMENT...1-3 REPEATER ANNUNCIATORS...1-3 Figure 1 - Master Warning Annunciations and Controls...1-4

More information

INSTRUCTIONS RHS 700. Recovery, Recycling, Evacuation and Charging Station RHS 700

INSTRUCTIONS RHS 700. Recovery, Recycling, Evacuation and Charging Station RHS 700 A GRAMKOW A/S Augustenborg Landevej 19 DK-6400 Sønderborg Denmark A/S Reg. No. 17 12 31 Telephone: 45 74 12 36 36 Telefax: 45 74 43 36 46 Telex: 5 23 18 Bank: Den Danske Bank, No. 32 27 INSTRUCTIONS Recovery,

More information

Soft Start Series MP700 Solid State, Reduced Voltage

Soft Start Series MP700 Solid State, Reduced Voltage Metron Fire Pump Controls and Accessories Soft Start Series MP700 Solid State, Reduced Voltage Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s

More information

SP-2400 & 2410 Series Smart Valve Positioner (Linear & Rotary)

SP-2400 & 2410 Series Smart Valve Positioner (Linear & Rotary) SP-2400 & 2410 series Positioner are the advanced smart valve positioners which provide easy installation and simple setting and offer the automation systems outstanding reliability in control performance

More information

JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER

JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER JBE LED Dimming Controller for 110V* & 220V/ 240V AC LED Systems Thank you for purchasing high quality

More information

Constant voltage 3-phase rectifier.

Constant voltage 3-phase rectifier. 11750a Constant voltage 3-phase rectifier. Page 1 of 11 11750a Mechanical assembly The rectifier is assembled in a cabinet intended for indoor wall mounting. The cabinet has ventilation holes on both sides

More information

Tankless On Demand Electric Water Heater

Tankless On Demand Electric Water Heater ECO FRIENDLY 98% EFFICIENT ENERGY & WATER SAVING Model MTX Tankless On Demand Electric Water Heater Available Up To 54 KW in Single or Three Phase Voltages Marine Approvals American Bureau of Shipping

More information

CU 300 GRUNDFOS INSTRUCTIONS. Installation and operating instructions

CU 300 GRUNDFOS INSTRUCTIONS. Installation and operating instructions GRUNDFOS STRUCTIONS CU 300 Installation and operating instructions No contact Overvoltage Undervoltage Dry running Speed reduction Overtemperature Overload Sensor alarm Declaration of Conformity We Grundfos

More information

MagnaValve Shot Flow Controller

MagnaValve Shot Flow Controller Instruction Manual MagnaValve Shot Flow Controller Electronics Inc. 56790 Magnetic Drive Mishawaka, Indiana 46545 1-800-832-5653 (Toll Free) Phone: 1-574-256-5001 Fax: 1-574-256-5222 E-mail: sales@electronics-inc.com

More information

Design. Innovations in Integrated Control Systems

Design. Innovations in Integrated Control Systems Design Innovations in Integrated Control Systems Halvard Foss Kongsberg Maritime AS October 17-18, 2006 Return to Session Directory Innovations in Integrated Control Systems Halvard Foss Kongsberg Maritime

More information

GB-DAS. Installation and user manual DEVIreg 850 controller

GB-DAS. Installation and user manual DEVIreg 850 controller GB-DAS Installation and user manual DEVIreg 850 controller 1 Table of Contents 1: User Manual System overview......................................... 3 General use..............................................

More information

Class 1 laser beam sensor safe for your eyes

Class 1 laser beam sensor safe for your eyes 113 Sensor SERIES Related Information General terms and conditions... F-7 About laser beam... P.199~ Sensor selection guide... P.1~ General precautions... P.11 PHOTO PHOTO PARTICUR MEASURE ITY panasonic.net/id/pidsx/global

More information

CU 300. Installation and operating instructions GRUNDFOS INSTRUCTIONS

CU 300. Installation and operating instructions GRUNDFOS INSTRUCTIONS GRUNDFOS STRUCTIONS CU 300 Installation and operating instructions No contact Overvoltage Undervoltage Dry running Speed reduction Overtemperature Overload Sensor alarm Other languages www.grundfos.com/cu300-manual

More information

Call us today! (800)

Call us today! (800) 150 TON AIR-COOLED CHILLER PA-ACCTR-150 Call us today! (800)341-4297 The 150-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable,

More information

Planning Elevator Relay Groups Programming Millenium for Windows Software

Planning Elevator Relay Groups Programming Millenium for Windows Software Installation Booklet: Elevator Control Unit (ECU) Introduction The Elevator Control Unit (ECU) is an option in the Millenium for Windows systems. Once you add an elevator in the software, each elevator

More information

ECONOBOOST EB II & EB III Compact Water Booster

ECONOBOOST EB II & EB III Compact Water Booster ECONOBOOST EB II & EB III Compact Water Booster The Stokvis EB II twin pump & EB III triple pump cold water booster units meet today s need for compact, reliable, high performance equipment with modest

More information

Across-the-Line SERIES MP300 Combined Manual and Automatic

Across-the-Line SERIES MP300 Combined Manual and Automatic Across-the-Line SERIES MP300 Combined Manual and Automatic Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s Standard for Centrifugal Fire Pumps

More information

Modular standard power units. Type ABSKG. Contents. Features. RE Edition: Replaces: Tank size 20, 40 and 60 liters

Modular standard power units. Type ABSKG. Contents. Features. RE Edition: Replaces: Tank size 20, 40 and 60 liters Modular standard power units Type ABSKG RE 51013 Edition: 09.13 Replaces: 04.06 Tank size 20, 40 and 60 liters Contents Features ABSKG-40_001_d Stable aluminum tank Modular design Compact power unit design

More information

Instruction Manual (Supplementary) Open Type Inverter

Instruction Manual (Supplementary) Open Type Inverter 1 Instruction Manual (Supplementary) Open Type Inverter TOSVERT VF-S11 Thank you for purchasing a Toshiba Open type TOSVERT VF-S11 series inverter. This Manual gives a supplementary explanation of some

More information

BRG-N100 BACnet Objects. BRG-N100 Modbus Register Map

BRG-N100 BACnet Objects. BRG-N100 Modbus Register Map BRIDGE I-P Units RS-485 Network Bridge with Configurable Display and Alarm Capability 100 SERIES BRG-N100 INSTALL / SETUP DOCUMENT PN: 930-0560 BRG-N100 TYPICAL WIRING DIAGRAM BRG-N100 NETWORK BRIDGE LED

More information

RF SCOUT PLUS INSTRUCTION MANUAL. Dielectric, LLC 22 Tower Rd. Raymond, ME Phone: January 2015, Rev B 1

RF SCOUT PLUS INSTRUCTION MANUAL. Dielectric, LLC 22 Tower Rd. Raymond, ME Phone: January 2015, Rev B 1 RF SCOUT PLUS INSTRUCTION MANUAL Dielectric, LLC 22 Tower Rd. Raymond, ME 04071 Phone: 800.341.9678 www.dielectric.com 21 January 2015, Rev B 1 WARNING Powering RF sensors above +30dBm (1W) will cause

More information

0-2 m/s Lo Alarm 0-6 m/s Hi Alarm Signal Stregth EASZ-12 Doppler Flow Switch Measuring Flow Worldwide

0-2 m/s Lo Alarm 0-6 m/s Hi Alarm Signal Stregth EASZ-12 Doppler Flow Switch Measuring Flow Worldwide Instruction Manual EESIFLO EASZ-12 Doppler Flow Switch 55 120 0-2 m/s Lo Alarm 0-6 m/s Hi Alarm 120 Signal Stregth EASZ-12 Doppler Flow Switch Measuring Flow Worldwide Doppler Flow Switch - EASZ-12 Introduction

More information

Spirit row offset bunker harvester

Spirit row offset bunker harvester Spirit 9200 2-row offset bunker harvester AVR takes 2-row harvesting to a new level! The Spirit 9200 takes 2-row offset bunker harvesters to a whole new level. The well-known Spirit concept has been further

More information

Class 1 laser beam sensor safe for your eyes

Class 1 laser beam sensor safe for your eyes 1129 PHOTO PHOTO PARTICUR Sensor SERIES Related Information General terms and conditions... F-3 About laser beam... P.193~ guide... P.121~ General precautions... P.19 Conforming to FDA regulations (-11

More information

Fuji Electronic VFC 084P-5T

Fuji Electronic VFC 084P-5T Fuji Electronic VFC 084P-5T Fuji s complete line of ring compressors is designed to meet the most critical application requirements. Each features an impeller, mounting base and housing manufactured of

More information

ANCHOR BOLT DETAIL. Non-Shrink Grout. Poured In Place, After Equipment Setting. "L" Type Anchor Bolt Carbon Steel AISI 304 S.S.

ANCHOR BOLT DETAIL. Non-Shrink Grout. Poured In Place, After Equipment Setting. L Type Anchor Bolt Carbon Steel AISI 304 S.S. ANCHOR BOLT DETAIL Heavy Flat Washer Heavy Hex Nut UNC Th'd Mounting Flange Of Equipment To Be Mounted C B A D Non-Shrink Grout. Poured In Place, After Equipment Setting. Heavy Flat Washer Heavy Hex Nut

More information

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control Installation and Operation Manual Temperature and Pressure Monitoring for Heating and Cooling Applications Temperature Monitoring Control VALVE OPEN ALARM System= 128 o F Alarm At= 130 o F RESET /BACK

More information

CONTENTS INSTALLATION 21 USING THE SIGNAL KEY 10 SPECIFICATION 23

CONTENTS INSTALLATION 21 USING THE SIGNAL KEY 10 SPECIFICATION 23 CONTENTS GENERAL INTRODUCTION TO B&G NETWORK 2 USING THE LIGHTS KEY 17 INTRODUCTION TO NETWORK DEPTH 3 EXAMPLE SYSTEMS USING NETWORK DEPTH 4 SETTING THE DISPLAY LANGUAGE 18 SELECTING THE DISPLAY MODE 5

More information

ACME ACME ENGINEERING & MANUFACTURING PB100 SPC-D INLET CONTROLLER. ACME ENGINEERING & MANUFACTURING CORP. PO BOX 978 Muskogee, OK 74402

ACME ACME ENGINEERING & MANUFACTURING PB100 SPC-D INLET CONTROLLER. ACME ENGINEERING & MANUFACTURING CORP. PO BOX 978 Muskogee, OK 74402 ACME ACME ENGINEEING & MANUFACTUING PB00 SPC-D INLET CONTOLLE ACME ENGINEEING & MANUFACTUING COP. PO BOX 978 Muskogee, OK 74402 Owners Manual PB00 SPC-D Table of Contents. atings and specifications...

More information

FR-4000 & FR-8000 Fire Alarm Monitor Installation Manual

FR-4000 & FR-8000 Fire Alarm Monitor Installation Manual FR-4000 & FR-8000 Fire Alarm Monitor Installation Manual Table of Contents Introduction 1 System Components 2 Wiring Block Diagram 3 Connection Diagram for One Sensor 4 Connection Diagram for Multiple

More information

E-20 COMPARTMENT FLOODING WATER LEVEL DETECTORS (INCLUDING SENSORS)

E-20 COMPARTMENT FLOODING WATER LEVEL DETECTORS (INCLUDING SENSORS) Guideline No.: E-20(201510) E-20 COMPARTMENT FLOODING WATER LEVEL DETECTORS (INCLUDING Issued date: October 20,2015 China Classification Society Foreword: This Guideline is a part of CCS Rules, which contains

More information

ECOPlus SERIES OF HIGH-PRESSURE METERING MACHINES

ECOPlus SERIES OF HIGH-PRESSURE METERING MACHINES ECOPlus SEIES OF HIGH-PESSUE METEING MACHINES The OMS ECOPlus series of high-pressure metering units provides the ideal solution for every PU application. eliability, ease of operation and attractive price-performance

More information

Technical Specification

Technical Specification Technical Specification Medical Air Plant Product Description The CPX medical air plant shall fully comply with the United Kingdom Department of Health (DoH) HTM02-01, HTM2022 and NHS Model Engineering

More information

CONTENTS USING THE LIGHTS KEY...31 NETWORK ALARMS...32 FAULT AND ERROR MESSAGES...33

CONTENTS USING THE LIGHTS KEY...31 NETWORK ALARMS...32 FAULT AND ERROR MESSAGES...33 CONTENTS CONTENTS... 1 GENERAL INTRODUCTION TO B&G NETWORK... 2 INTRODUCTION TO NETWORK QUAD... 3 EXAMPLE SYSTEMS USING NETWORK QUAD... 4 SELECTING THE DISPLAY MODE... 5 USING THE SPEED KEY... 6 CALIBRATION

More information

Class 1 laser beam sensor safe for your eyes

Class 1 laser beam sensor safe for your eyes 13 Sensor SERIES Related Information General terms and conditions... F-17 About laser beam... P.13~ Sensor selection guide... P.967~ General precautions... P.1 PHOTO PHOTO Conforming to EMC Directive Conforming

More information

Instructions for the hand-held micro terminal of the fan motor control system, TBLZ-2-75 SILVER C

Instructions for the hand-held micro terminal of the fan motor control system, TBLZ-2-75 SILVER C Instructions for the hand-held micro terminal of the fan motor control system, TBLZ-2-75 SILVER C 1. General The hand-held micro terminal is used for setting the motor parameters of the SILVER C. 2. Installation

More information

Operating Manual RCM420

Operating Manual RCM420 Operating Manual RCM420 Residual current monitor for AC current monitoring in TN and TT systems Software version: D240 V1.2x TGH1410en/03.2012 Bender GmbH & Co. KG Londorfer Str. 65 35305 Grünberg Germany

More information

Flostop TS D7E and A8E. Operation Manual

Flostop TS D7E and A8E. Operation Manual Flostop TS D7E and A8E Operation Manual United Kingdom Spectron Gas Control Systems Ltd, Unit 4, ATU1, University of Warwick science Park, Coventry, +44 (0) 24 7641 6234 sales@spectron-gcs.com Germany

More information

monty 4200 Truck Tire Changer Spare Parts list

monty 4200 Truck Tire Changer Spare Parts list monty 4200 Truck Tire Changer Spare Parts list Date 08/12/09 Figure 1 Baseframe Date 08/12/09 Page 2 Monty 4200 Spare Parts list Figure 2A Carriage with Mounting Arm Date 08/12/09 Page 3 Monty 4200 Spare

More information

Flopurge TS. Operation Manual

Flopurge TS. Operation Manual Flopurge TS Operation Manual Part Number 079-0204 Spectron Gas Control Systems United Kingdom Unit 4, Herald Court, University of Warwick Science Park, Coventry, CV4 7EZ +44 (0)24 7641 6234 sales@spectron-gcs.com

More information

Technical Manual. Electropneumatic Level Measuring System TYPE TN3801

Technical Manual. Electropneumatic Level Measuring System TYPE TN3801 TYPE TN3801 Technical Manual SAS au Capital de 2 158 244-444 871 933 R.C.S. Bourges - APE : 2651B Headquarter : 9, rue Isaac Newton - 18000 Bourges - France Technical Manual TYPE TN3801 1 st Edition Released

More information

Safety Instructions MS 10B ALARM UNIT MS 10B ALARM UNIT. Used symbols. Always observe this information to prevent damage to the device

Safety Instructions MS 10B ALARM UNIT MS 10B ALARM UNIT. Used symbols. Always observe this information to prevent damage to the device Safety Instructions Used symbols Important Comments Before starting with installation of the MS 10B Alarm Unit, we recommend you to read the important information beneath. Qualification The installation

More information

Fratech Multipath-IP

Fratech Multipath-IP Rev 2.0 (May 2013) Installer Manual 1 Current Part Numbers: Fratech Multipath-IP E-Link STU PCB & Accessory Kit only In Metal Enclosure with Power Supply 998325-PK 998325-XS Installer Manual This document

More information

SPECIFICATION MAZARIN 72 4 CABIN VERSION

SPECIFICATION MAZARIN 72 4 CABIN VERSION DECK Stainless steel anchor 50 kg with 55 m chain (13 mm) Electric windlass with two operating units Separate fender locker Stainless steel bow fitting 10 Stainless steel belaying cleats Deck hatches,

More information

2012 Toolbar & NH3 Operators Manual

2012 Toolbar & NH3 Operators Manual 2012 Toolbar & NH3 Operators Manual P/N 320379 Amity Technology, LLC 2800 7th Avenue North Fargo, ND 58102 (701) 232-4199 www.amitytech.com This Page Left Intentionally Blank Page 2 2012 Toolbar/NH3 Manual

More information

Section - III SYSTEMS DESCRIPTION

Section - III SYSTEMS DESCRIPTION Section - III SYSTEMS DESCRIPTION Pro Line 21 Table of Contents Page GENERAL... 7-3 SYSTEM LOGIC... 7-3 CONTROLS and ANNUNCIATIONS... 7-3 OPERATION... 7-4 STALL WARNING SYSTEM... 7-4 STALL IDENTIFICATION

More information

Pneumatic Grain Conveying

Pneumatic Grain Conveying Pneumatic Grain Conveying Flexible Pneumatic Conveying Solutions Moving agriculture ahead High Pressure Blowers Outlet cyclone Outlet cyclone Blower Receiving hopper Blower Injector Pressure conveying

More information

Type 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B

Type 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B PRODUCT BULLETIN SB 8001B Type 8001 ALARM ANNUNCIATOR TYPE8001 FEATURES 16 or 32 alarm points per flush mount enclosure Displays are backlit with long life LEDs and engraved to suit Dimmer controls built

More information

02/11/2015

02/11/2015 CTH 46 - CTD 43 / 46 CTD 46 Part number 89422108 CTH 46 Heating / cooling function Measurement and setpoint display CTD 43 Heating or cooling function Measurement display Measurement deviation display-setpoint

More information