CH 4 C 2 H 2 C 3 H 8 CO 2 H 2 H 2 S HFC NH 3 NO 2 O 2 O 3 SO 2

Size: px
Start display at page:

Download "CH 4 C 2 H 2 C 3 H 8 CO 2 H 2 H 2 S HFC NH 3 NO 2 O 2 O 3 SO 2"

Transcription

1 PluraSens CH 4 C 2 H 2 C 3 H 8 CO CO 2 H 2 H 2 S HFC NH 3 NO 2 O 2 O 3 SO 2 VOC E2600 Family Gas Detectors

2 E2610 Series Compact wall-mount housing providing optimal airflow Integrated sensor with long lifetime ( years) Wide operating temperature range (-40/-30 to +70 C) Available for combustible gases, Ammonia, VOC and Carbon Monoxide Easy installation and maintenance High accuracy and stability Two relays with switch-over contact Flashing LED and an internal buzzer Available with 230 VAC or 24 VDC power supply Affordable price and low maintenance costs

3 E2611 Series 4-20mA 0-10V RS485 Modbus Compact wall-mount housing providing optimal airflow Integrated accurate and stable sensor with long lifetime ( years) Wide operating temperature range (-40/-30 to +70 C) Available for Combustibles, Ammonia and Volatile Organic Compounds Two independent user configurable analog outputs 0-10 V / 4-20 ma interface for Fieldbus networking Two configurable relays with closing contact, internal buzzer option Available with 230 VAC or 24 VDC power supply Easy installation and maintenance Affordable price and low maintenance costs

4 E2618 Series IP mA 0-10V RS485 Modbus 24 VDC powered point transmitters for gas detection systems Dust- and watertight enclosure for harsh environment Available for wide range of combustible, toxic gases and oxygen Attached, duct-mount or remote sensor probe options Two independent user configurable analog outputs 0-10 V / 4-20 ma interface for Fieldbus networking Easy installation and maintenance Competitive price and low maintenance costs

5 E2608 Series IP mA 0-10V RS485 Modbus Dust- and watertight enclosure for harsh environment Available for wide range of combustible, toxic gases and oxygen Attached, duct-mount or remote sensor probe options Two independent user configurable analog outputs 0-10 V / 4-20 ma interface for Fieldbus networking Two configurable relays with closing contact Available with 230 VAC or 24 VDC power supply Easy installation and maintenance Competitive price and low maintenance costs

6 Hydrogen detection Mandatory in confined spaces, where potentially explosive concentration of hydrogen gas can accumulate as a result of generation or leaks. As hydrogen is lighter than air and tends to rise up, hydrogen detectors should be mounted near the ceiling in proximity to potential sources. Recommended coverage area for each hydrogen detector is m 2 and corresponding coverage radius m. Battery charging rooms Gas cylinders storage Gas testing equipment, gas blending benches Wastewater treatment plants Laboratories, research environment Vehicle fuel cells, hydrogen filling stations Type E2610-LEL E2611-H2 E2618-H2 E2608-H2 Enclosure IP20 - dry rooms IP20 - dry rooms IP65 - damp rooms IP65 - damp rooms Semiconductor type, integrated Semiconductor type, integrated Outputs - Semiconductor or catalytic type, Alarms Blinkng LED & Buzzer Buzzer - - Relays 2 x SPDT 2 x SPST - 2 x SPST Semiconductor or catalytic type, Power 24 VDC / 230 VAC 24 VDC / 230 VAC 24 VDC 24 VDC / 230 VAC E2600 series combustible gas detectors operate in the range % LEL and are intended for safe (not ATEX rated) areas.

7 Methane detection Mandatory in confined spaces, where potentially explosive concentration of methane (natural gas) can accumulate as a result of generation or leaks. As methane is lighter than air and tends to rise up, methane detectors should be mounted near the ceiling in proximity to potential sources. Recommended coverage area for each methane detector is m 2 and corresponding coverage radius m. Boiler rooms, commercial kitchens Biogas production plants Gas pipelines and compressor stations Gas blending and testing equipment, cylinders storage Wastewater treatment plants Laboratories, research environment Type E2610-LEL E2611-CH4 E2618-CH4 E2608-CH4 Enclosure IP20 - dry rooms IP20 - dry rooms IP65 - damp rooms IP65 - damp rooms Semiconductor type, integrated Semiconductor type, integrated Outputs - Semiconductor or catalytic type, Alarms Blinkng LED & Buzzer Buzzer - - Relays 2 x SPDT 2 x SPST - 2 x SPST Semiconductor or catalytic type, Power 24 VDC / 230 VAC 24 VDC / 230 VAC 24 VDC 24 VDC / 230 VAC E2600 series combustible gas detectors operate in the range % LEL and are intended for safe (not ATEX rated) areas.

8 LPG detection Mandatory in confined spaces, where potentially explosive concentration of liquefied petroleum gas (LPG) can accumulate as a result of leaks. As butane and propane, the main constituents of LPG, are heavier than air and tend to sink down, LPG detectors should be mounted near the floor in proximity to potential sources. Recommended coverage area for each LPG detector is m 2 and corresponding coverage radius m. LPG plants and facilities LPG boiler houses, commercial kitchens Underground parkings, storage rooms Laboratories, research environment Type E2610-LEL E2611-LPG E2618-LPG E2608-LPG Enclosure IP20 - dry rooms IP20 - dry rooms IP65 - damp rooms IP65 - damp rooms Semiconductor type, integrated Semiconductor type, integrated Outputs - Semiconductor or catalytic type, Alarms Blinkng LED & Buzzer Buzzer - - Relays 2 x SPDT 2 x SPST - 2 x SPST Semiconductor or catalytic type, Power 24 VDC / 230 VAC 24 VDC / 230 VAC 24 VDC 24 VDC / 230 VAC E2600 series combustible gas detectors operate in the range % LEL and are intended for safe (not ATEX rated) areas.

9 Ammonia detection Ammonia is a highly hazardous toxic and corrosive chemical, used as a refrigerant (R717) for very low temperatures. EU Standard EN378:2008 requires that all plants with a charge over 50 kg NH 3 must have a gas detection system installed. Ammonia emissions from animal waste in intensive livestock and poultry farms may affect animal health and productivity. As ammonia is lighter than air and tend to rise up, NH 3 detectors should be mounted near the ceiling in proximity to potential leak sources, or located in breathing area. Recommended coverage area for each NH 3 detector is m 2 and corresponding coverage radius m. Large industrial refrigeration systems Animal agriculture (livestock and poultries) Fertilizer production and storage Laboratories, research environment Type E2610-NH3 E2611-NH3 E2618-NH3 E2608-NH3 Enclosure IP20 - dry rooms IP20 - dry rooms IP65 - damp rooms IP65 - damp rooms Semiconductor type, integrated Semiconductor type, integrated Outputs - Semiconductor or electrochemical type, Alarms Blinkng LED & Buzzer Buzzer - - Relays 2 x SPDT 2 x SPST - 2 x SPST Semiconductor or electrochemical type, Power 24 VDC / 230 VAC 24 VDC / 230 VAC 24 VDC 24 VDC / 230 VAC E2600 series gas detectors are intended for safe (not ATEX rated) areas.

10 Halocarbon detection Halocarbon based refrigerant gas leaks should be detected, as older сhlorofluorocarbons (CFCs) are ozone-depleting and newer hydrofluorocarbons (HFCs) are relatively expensive. Refrigerant leaks may also result in dangerous displacement of oxygen in closed rooms. As halocarbon refrigerants are heavier than air and tend to sink down, refrigerant gas detectors should be mounted close to the floor in proximity to potential leak sources. Recommended coverage area for each refrigerant detector is m 2 and corresponding coverage radius m. Cold storage warehousing Refrigerated plants Mechanical/Chiller Rooms Ice Scating Arenas Type E2618-HFC E2608-HFC Enclosure IP65 - damp rooms IP65 - damp rooms Outputs Semiconductor type, Alarms - - Semiconductor type, Relays - 2 x SPST Power 24 VDC 24 VDC / 230 VAC E2600 series gas detectors are intended for safe (not ATEX rated) areas.

11 Carbon Monoxide detection Carbon monoxide (CO) is a highly toxic, colorless and odorless gas. Monitoring is required in places where CO may be formed from incomplete combustion. CO is very close to the same density as air, so the gas tends to spread evenly in the room. Carbon monoxide detectors should be mounted in the breathing zone at a height ~1,5 m from the floor in proximity to potential leak sources. Recommended coverage area for each CO detector is m 2 and corresponding coverage radius m. Indoor parking, vehicle service centers Boiler and burner rooms Factories and warehouses Tunnels Wastewater treatment plants Incineration facilities Type E2610-CO E2618-CO E2608-CO Enclosure IP20 - dry rooms IP65 - damp rooms IP65 - damp rooms Electrochemical type, integrated Electrochemical type, attached, duct or remote Outputs - Alarms Blinkng LED & Buzzer - - Relays 2 x SPDT - 2 x SPST Electrochemical type, attached, duct or remote Power 24 VDC / 230 VAC 24 VDC 24 VDC / 230 VAC E2600 series CO gas detectors are intended for safe (not ATEX rated) areas.

12 Carbon Dioxide detection Carbon dioxide (CO 2 ) level is a primary indicator of indoor air quality. Monitoring of CO 2 is required for demand controlled ventilation in occupied places, to prevent oxygen depletion by CO2 leaks in confined rooms, and to ensure optimal atmosphere for growth of plants and mushrooms. CO 2 is slightly heavier air, but the gas tends to spread evenly in the room. Carbon dioxide detectors should be mounted in the breathing zone at a height ~1,5 m from the floor. Recommended coverage area for each CO 2 detector is m 2 and corresponding coverage radius m. Public buldings, theaters, cinemas, concert halls HVAC in office buildings, hotels Factories, refrigeration facilities Greenhouses and mushroom plants Type E2609-CO2 E2618-CO2 E2608-CO2 Enclosure IP20 - dry rooms IP65 - damp rooms IP65 - damp rooms Outputs Optical NDIR type, integrated 0-10 V Optical NDIR type, attached, duct or remote Alarms Relays 1 x SPDT - 2 x SPST Optical NDIR type, attached, duct or remote Power 24 VDC 24 VDC 24 VDC / 230 VAC E2600 series CO 2 gas detectors are intended for safe (not ATEX rated) areas.

13 Oxygen detection Oxygen may be dangerously displaced in closed rooms by other neutral gases, like argon, refrigerants, CO 2 etc. Oxygen depletion detectors should be mounted in the breathing zone at a height ~1,5 m from the floor. Recommended coverage area for each O 2 detector is m 2 and corresponding coverage radius m. Inert gas storages, confined spaces Modified atmospheres (filling of windows and packages) Nitrogen blanketing in industrial processes Incubators, fermentation vessels Type E2618-O2 E2608-O2 E2811-RP33-O2 Enclosure IP65 - damp rooms IP65 - damp rooms IP65 - damp rooms Outputs Electrochemical type, attached, duct or remote Electrochemical type, attached, duct or remote Alarms Relays - 2 x SPST - Electrochemical type, Zigbee wireless, range m Power 24 VDC 24 VDC / 230 VAC 3V Li battery, up to 3 years E2600 / E2800 series gas detectors are intended for safe (not ATEX rated) areas.

14 Ozone detection Ozone is a non-flammable gas, colorless to blue in color with very pungent odor. It is a powerful oxidizer, attacks the eyes and respiratory system and can cause pulmonary edema. Used as powerful desinfectant and purifier agent. Swimming pools, spas Food processing and preservation Water treatment and purification Air purification and sterilization Type E2618-O3 E2608-O3 E2811-RP33-O3 Enclosure IP65 - damp rooms IP65 - damp rooms IP65 - damp rooms Outputs Electrochemical type, attached, duct or remote Electrochemical type, attached, duct or remote Alarms Relays - 2 x SPST - Electrochemical type, Zigbee wireless, range m Power 24 VDC 24 VDC / 230 VAC 3V Li battery, up to 3 years E2600 / E2800 series gas detectors are intended for safe (not ATEX rated) areas.

15 Acetylene detection Acetylene is colorless combustible gas slightly lighter than air. It is widely used in metal welding and cutting. Leaks of acetylene should be carefully monitored, as it is highly explosive material. Metal welding and cutting Cylinder storage rooms Industry Laboratories, research environment Type E2610-LEL E2611-C2H2 E2618-C2H2 E2608-C2H2 Enclosure IP20 - dry rooms IP20 - dry rooms IP65 - damp rooms IP65 - damp rooms Semiconductor type, integrated Semiconductor type, integrated Outputs - Semiconductor or catalytic type, Alarms Blinkng LED & Buzzer Buzzer - - Relays 2 x SPDT 2 x SPST - 2 x SPST Semiconductor or catalytic type, Power 24 VDC / 230 VAC 24 VDC / 230 VAC 24 VDC 24 VDC / 230 VAC E2600 series gas detectors are intended for safe (not ATEX rated) areas.

16 Ethylene detection Extremely flammable colourless gas. Widely used as a row material in polymer industry and as a fruit ripener. Detection is mandatory in confined spaces, where potentially explosive concentration of ethylene can accumulate as a result of leaks. Agriculture Industry Gas storage rooms Laboratories, research environment Type E2618-C2H4 E2608-C2H4 Enclosure IP65 - damp rooms IP65 - damp rooms Outputs Electrochemical Alarms - - Electrochemical Relays - 2 x SPST Power 24 VDC 24 VDC / 230 VAC E2600 series gas detectors are intended for safe (not ATEX rated) areas.

17 Sulfur dioxide detection Sulfur dioxide is colourless gas with pungent odour. It is an intermediate in the production of sulfuric acid. SO 2 is used as reductant, as bleaching agent for delicate materials and as a preservative in food industry and winemaking. Sulfur dioxide is toxic when inhaled. As sulfur dioxide is heavier than air and tend to sink down, refrigerant gas detectors should be mounted at cm above the floor in proximity to potential leak sources. Chemical industry Winemaking Food processing and preservation Laboratories Type E2618-SO2 E2608-SO2 Enclosure IP65 - damp rooms IP65 - damp rooms Outputs Electrochemical, Alarms - - Electrochemical, Relays - 2 x SPST Power 24 VDC 24 VDC / 230 VAC E2600 series gas detectors are intended for safe (not ATEX rated) areas.

18 Chlorine detection Cl 2 Clorine is yellow-greenish gas with pungent odour. It is used as desinfectant and bleaching agent in the manufacturing of industrial and consumer products. Chlorine is a toxic gas that irritates the respiratory system. Being a strong oxidizer, it may react with flammable materials. As chlorine is heavier than air and tend to sink down, detectors should be mounted close to the floor in proximity to potential leak or generation sources. Chemical and polymer industry Swimming pools Water treatment plants Laboratories Type E2618-Cl2 E2608-Cl2 Enclosure IP65 - damp rooms IP65 - damp rooms Outputs Electrochemical, Alarms - - Electrochemical, Relays - 2 x SPST Power 24 VDC 24 VDC / 230 VAC E2600 series gas detectors are intended for safe (not ATEX rated) areas.

19 Nitrogen dioxide detection Nitrogen dioxide is brown gas with pungent odour. It is formed in most combustion processes when using air as the oxidant. Nitrogen dioxide is toxic when inhaled. At low concentrations it anesthetizes the nose, thus creating a potential for overexposure. As nitrogen dioxide is heavier than air and tends to sink down, detectors should be mounted close to the floor in proximity to potential sources. Indoor parkings, skating arenas, tunnels Thermal power stations Pulp mills Laboratories Type E2618-NO2 E2608-NO2 Enclosure IP65 - damp rooms IP65 - damp rooms Outputs Electrochemical, Alarms - - Relays - 2 x SPST Electrochemical, Power 24 VDC 24 VDC / 230 VAC E2600 series gas detectors are intended for safe (not ATEX rated) areas.

20 Hydrogen sulfide detection Colorless gas with charasteristic odour of rotten eggs. It is slightly heavier than air, very poisonous, corrosive, flammable, and explosive. At high concentrations it causes the paralysis of olfactory nerve, which increase the risk of overexposure. Hydrogen sulfide results from anaerobic decay of organic matter, e.g. in sinks, sewers etc. Wastewater and sewage treatment plants Paper and pulp mills Food and beverages industry Laboratories Type E2618-H2S E2608-H2S Enclosure IP65 - damp rooms IP65 - damp rooms Outputs Electrochemical, Alarms - - Electrochemical, Relays - 2 x SPST Power 24 VDC 24 VDC / 230 VAC E2600 series gas detectors are intended for safe (not ATEX rated) areas.

21 Battery Charging Rooms Safety of battery back-up installations for various electronic systems has to be monitored. As lead acid batteries are charged, hydrogen gas is produced, which may accumulate and reach hazardous combustible levels in confined spaces. Gas Typical range Transmitter Detector Hydrogen H %LEL E2618-H2 E2608-H2 E2610-LEL E2611-H2 Boiler Houses Control of leaks of combustible gases and Carbon Monoxide Gas Typical range Transmitter Detector Carbon Monoxide CO ppm E2618-CO Methane CH %LEL E2618-CH4 Propane C 3 H %LEL E2618-LPG E2608-CO E2610-CO E2608-CH4 E2610-LEL E2611-CH4 E2610-LEL E2611-LPG E2608-LPG Hotels, Libraries, Restaurants Control of indoors air quality and leaks of refrigerants Gas Typical range Transmitter Detector Carbon Dioxide CO ppm E2618-CO2 E2608-CO2 E2609-CO2 Halocarbon Refrigerants ppm E2618-HFC E2608-HFC

22 Ice Scating Arenas Air quality of public indoor environments has to be monitored for people safety. Ice resurfacing equipment operated in closed arenas releases CO and NO 2 gases from the burning of fuel. Dehumidification equipment can lead CO gas into the ventilation system. Leaks of refrigerant gases (propane, halocarbons, ammonia) can occur in refrigeration equipment. Gas Typical range Transmitter Detector Carbon Monoxide CO ppm E2618-CO E2608-CO E2610-CO Nitrogen Dioxide NO ppm E2618-NO2 E2608-NO2 Propane C 3 H %LEL E2618-LPG Ammonia NH ppm E2618-NH3 E2608-LPG E2610-LEL E2608-NH3 E2610-NH3 Halocarbon Refrigerants ppm E2618-HFC E2608-HFC Indoor Parking and Service Garages By monitoring the concentration of toxic vehicle exhaust fumes and ventilating based on their concentration, a safe environment in garages and economical ventilation can be ensured. For gasoline, natural gas, propane powered vehicles, CO should be detected. For vehicles with diesel engines, NO 2 levels should be measured. Alternatively, CO 2 as general air quality indicator may be monitored. Gas Typical range Transmitter Detector Carbon Monoxide CO ppm E2618-CO E2608-CO E2610-CO Nitrogen Dioxide NO ppm E2618-NO2 E2608-NO2 Carbon Dioxide CO ppm E2618-CO2 E2608-CO2 E2609-CO2

23 Pulp and Paper Industry Pulp and paper mills can present many dangerous situations, which can be significantly decreased by utilizing toxic gas monitoring. Gas Typical ranges Transmitter Detector Hydrogen Sulfide H 2 S ppm E2618-H2S E2608-H2S Sulfur Dioxide SO ppm E2618-SO2 E2608-SO2 Food and Beverages Industry Whether pre-cooking food, treating wastes and byproducts or ensuring food is preserved properly for shipment, food and beverage processors use and produce dangerous gases. As a result, gas detection is an important part of the everyday safety requirements for these processing facilities. Gas Typical ranges Transmitter Detector Propane C 3 H %LEL E2618-LPG Carbon Monoxide CO ppm E2618-CO Carbon Dioxide CO ppm E2618-CO2 E2608-LPG E2610-LEL E2608-CO E2610-CO E2608-CO2 E2609-CO2 Nitrogen Dioxide NO ppm E2618-NO2 E2608-NO2 Hydrogen Sulfide H 2 S ppm E2618-H2S E2608-H2S Ammonia NH ppm E2618-NH3 E2608-NH3 E2610-NH3 Halocarbon Refrigerants ppm E2618-HFC E2608-HFC Volatile Organic Compounds VOC ppm %LEL E2618-VOC E2608-VOC E2610-VOC E2611-VOC Oxygen Deficiency O %vol E2618-O2 E2608-O2 Ozone O ppm E2618-O3 E2608-O3

24 Refrigeration Leaks of refrigerant gases (propane, halocarbons, ammonia, CO 2 ) can occur in refrigeration equipment. Refrigerant leaks may also result in dangerous displacement of oxygen in closed rooms. Gas Typical range Transmitter Detector Carbon Dioxide CO ppm E2618-CO2 Propane C 3 H %LEL E2618-LPG Ammonia NH ppm E2618-NH3 E2608-CO2 E2609-CO2 E2608-LPG E2610-LEL E2608-NH3 E2610-NH3 Halocarbon Refrigerants ppm E2618-HFC E2608-HFC Solvent Storages and Painting Chambers Toxic and flammable vapors of volatile organic compounds (VOC), like ethanol, toluene, xylene may accumulate and reach hazardous combustible levels in confined spaces. Gas Typical ranges Transmitter Detector Volatile Organic Compounds VOC ppm %LEL E2618-VOC E2608-VOC E2610-VOC E2611-VOC Swimming Pools and Spas Control of leaks of water desinfectants Cl 2 and O 3 to ensure safety of people. Gas Typical range Transmitter Detector Chlorine Cl ppm E2618-CL2 E2608-CL2 Ozone O ppm E2618-O3 E2608-O3

25 Wastewater Treatment Wastewater treatment process creates a range of inert, toxic and combustible gases, which can build up in enclosed spaces or deplete oxygen to endanger plant personnel, and therefore shall be monitored. Gas Typical range Transmitter Detector Methane CH %LEL E2618-CH4 E2608-CH4 Hydrogen H %LEL E2618-H2 E2608-H2 Hydrogen Sulfide H 2 S ppm E2618-H2S E2608-H2S Carbon Monoxide CO ppm E2618-CO E2608-CO Oxygen Deficiency O %vol E2618-O2 E2608-O2 Chlorine Cl ppm E2618-CL2 E2608-CL2 Sulfur Dioxide SO ppm E2618-SO2 E2608-SO2 Ozone O ppm E2618-O3 E2608-O3 Workshops and Welding Toxic and flammable gases and oxygen deficiency must be monitored for worker safety. Gas Typical range Transmitter Detector Acetylene C 2 H %LEL E2618-C2H2 E2608-C2H2 Nitrogen Dioxide NO ppm E2618-NO2 E2608-NO2 Carbon Dioxide CO ppm E2618-CO2 E2608-CO2 Carbon Monoxide CO ppm E2618-CO E2608-CO Oxygen Deficiency O %vol E2618-O2 E2608-O2 Ozone O ppm E2618-O3 E2608-O3

Macurco Gas Detection Products

Macurco Gas Detection Products Macurco Gas Detection Products 1 Macurco 6-Series Detector, Controller and Transducer 2 Macurco 6-Series Detector, Controller and Transducer The Macurco 6-Series is the new platform for the Macurco commercial

More information

Murco Core Product Guide Gas Leak Detection Solutions for all your building needs

Murco Core Product Guide Gas Leak Detection Solutions for all your building needs Murco Core Product Guide Gas Leak Detection Solutions for all your building needs Refrigerant Gases Toxic Gases Combustible Gases VOC s Legislation: F Gas Regulation, EH40 Standards: EN378 Lloyds Approval

More information

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display. Sheet No. 1 of 4 monitor/analyzer with alarm and Graphical Display. Sheet No. 2 of 4 It specially designed to analyze any gas of your choice, its automatic operation, accurate measurement and crystal clear

More information

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6 Digital Gas Transmitters with Auxiliary s & Control Specifications subject to change without notice. USA 181011 Page 1 of 5 DESCRIPTION Digital RS-485 communicating, addressable toxic and combustible gas

More information

compact detector Detection of more than 200 flammable and toxic gases iso 9001:2008

compact detector Detection of more than 200 flammable and toxic gases iso 9001:2008 iso 9001:2008 Quality Management Systems Systéme de Qualité www.sgs.com possibility of additional functions detection of critical temperature detection of flooding electrochemical sensor catalytic sensor

More information

Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features.

Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features. Features To measure and take control of indoor air quality Three noses in same unit Air Quality (VOC), Humidity (rh) and Temperature (T) Selectable outputs 0-10 Vdc, 4-20 ma or 0-5 Vdc via jumpers on pcb

More information

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66. Fixed Gas Monitoring Solutions Detection of explosive gases, toxic gases and oxygen Infrared XP IR version SIL 2 high reliability IP 66 E n o r t c e l i c 3years W a r r a t n y Certifications: The Fixed

More information

Carbon Monoxide (CO) Gas Detectors with (0)2-10 Vdc or (0)4-20 ma Output

Carbon Monoxide (CO) Gas Detectors with (0)2-10 Vdc or (0)4-20 ma Output Features Electrochemical sensor element (0)2-10 Vdc or (0)4-20 ma output, jumper selectable Standard IP65 plastic enclosure Measuring ranges 0-50 ppm 0-100 ppm 0-150 ppm 0-200 ppm 0-250 ppm 0-300 ppm 0-500

More information

Portable Instrument Application Guide

Portable Instrument Application Guide Portable Instrument Application Guide Which Portable Gas Detector for which Industry/Application Because every life has a purpose... Gas Detection Instruments Advanced Technology Advanced technology employed

More information

ASHRAE Safety Standards. Mechanical Rooms and Gas Detection in Commercial Applications

ASHRAE Safety Standards. Mechanical Rooms and Gas Detection in Commercial Applications HA University ASHRAE Safety Standards Mechanical Rooms and Gas Detection in Commercial Applications presented by Greg Kaufman - Honeywell Analytics Gas Hazards Three main types of Gas Hazards: Flammable

More information

Your trusted partner in providing the best fixed Gas Detection Sales and Service in Western Canada

Your trusted partner in providing the best fixed Gas Detection Sales and Service in Western Canada Your trusted partner in providing the best fixed Gas Detection Sales and Service in Western Canada MultiGas Detection Ltd. Introduction & Capabilities Leduc Head Office Calgary Office MultiGas Detection

More information

OLC(T) 100 FIXED GAS DETECTOR

OLC(T) 100 FIXED GAS DETECTOR Fixed Gas Detector OLC(T) FIXED GAS DETECTOR Detection of explosive gases, toxic gases or oxygen Infrared XP version SIL 2 high reliability IP 66 Aluminium or Stainless Steel version CERTIFICATIONS The

More information

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY FEATURES TXGARD & FLAMGARD PLUS Digital display with flexible output options Wide range of long life sensors Non-intrusive one-man

More information

SIL 2. Ultima X Series Gas Monitors CERTIFIED

SIL 2. Ultima X Series Gas Monitors CERTIFIED Ultima X Series Gas Monitors 5 Now with SIL 2 CERTIFIED Products Versatile fixed instruments provide continuous monitoring of many hazardous gases using catalytic, electrochemical, and infrared gas detection

More information

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People Fixed Gas Detector Detection of explosive gases, toxic gases or oxygen Infrared XP version SIL 2 high reliability IP 66 Certifications The Fixed Gas Detection People The OLC/OLCT CT range of fixed ddetectors

More information

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors Ultima X Series Gas Monitors Versatile fixed instruments provide continuous monitoring of many hazardous gases using catalytic, electrochemical, and infrared gas detection methods. HART Protocol is now

More information

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version Fixed Gas Detector Detection of explosive gases, toxic gases or oxygen Infrared XP version SIL 2 high reliability IP 66 Aluminium or Stainless Steel version Certifications Pending The Fixed Gas Detection

More information

EXAMPLES OF HOW TO ORDER

EXAMPLES OF HOW TO ORDER E 3 Point PRODUCT SUBMITTAL Toxic and Combustible Gas Detector Standalone Platform (Single or Dual-Gas Monitoring) ORDERING INFORMATION Single-Gas or Dual-Gas Configuration: Base Unit, Surface-Mount Base

More information

GAS DETECTION MANUFACTURED BY. Aerionics, Inc. Sioux Falls, SD Phone:

GAS DETECTION MANUFACTURED BY. Aerionics, Inc. Sioux Falls, SD Phone: CM-1 CO ppm MANUFACTURED BY Aerionics, Inc. Sioux Falls, SD Phone: 1-877-367-7891 Email: info@aerionicsinc.com www.macurco.com Detectors for use with Fire and Security Systems The Macurco CM-E1, GD-2B,

More information

EXAMPLES OF HOW TO ORDER

EXAMPLES OF HOW TO ORDER E 3 Point PRODUCT SUBMITTAL Toxic and Combustible Gas Detector Standalone Platform (Single or Dual-Gas Monitoring) ORDERING INFORMATION Single-Gas or Dual-Gas Configuration: Base Unit, Surface-Mount Base

More information

CO2 transmitters TRANSMITTERS TO DETECT CARBON DIOXIDE (CO 2 )

CO2 transmitters TRANSMITTERS TO DETECT CARBON DIOXIDE (CO 2 ) CO2 transmitters TRANSMITTERS TO DETECT CARBON DIOXIDE (CO 2 ) Measure carbon dioxide (CO2), carbon monoxide (CO) and temperature (T) Infrared measurement technology (NDIR) Automatic calibration eliminates

More information

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro A d e v i h c r D c o n e m u WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free from defects in workmanship

More information

3M Oldham OLCT 100. Description. Fixed Gas Detector

3M Oldham OLCT 100. Description. Fixed Gas Detector Fixed Gas Detector Description The OLC/OLCT range of fixed detectors has been designed for detection of combustible gases, toxic gases or oxygen. Available in explosion-proof or intrinsically safe versions,

More information

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required Sieger Sensepoint The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a high quality, low cost solution to their industrial gas monitoring needs. Sieger Sensepoint Fit For Purpose

More information

Sieger Apex. Flexibility that meets your requirements

Sieger Apex. Flexibility that meets your requirements Sieger Apex Flexibility that meets your requirements Sieger Apex Easy to Install Sensor can be remotely mounted up to 100m from the transmitter On board relays allow for local audible/ visual alarms Strong

More information

Two-Channel Gas Controller

Two-Channel Gas Controller Two-Channel Gas Controller Specifications subject to change without notice. USA 09 Page of DESCRIPTION Highly configurable, UL 0 performance-tested and -certified, and wall-mounted gas monitor; continuously

More information

Warranty Registration

Warranty Registration WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free from defects in workmanship and materials for a period

More information

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility EAGLE 2 Inlet fitting Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility Internal / external hydrophobic filters Self healing polyurethane protective

More information

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required Sieger Sensepoint The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a high quality, low cost solution to their industrial gas monitoring needs. Sieger Sensepoint Fit For Purpose

More information

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification 1.0 This specification details the attributes and operating characteristics of the MSA Ultima X Series sensors/transmitters.

More information

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS FEATURES Extremely wide range of sensors Easy installation and maintenance Low cost of ownership Replacement of sensors are simple Rugged and reliable

More information

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector. Introduction United Safety applies the detection system as a multi-point monitoring for toxic gases, combustibles and oxygen hazards. Self-powered and solar-capable, the features unequaled versatility,

More information

Xgard. Fixed detectors For flammable, toxic or oxygen gases

Xgard. Fixed detectors For flammable, toxic or oxygen gases Fixed detectors For flammable, toxic or oxygen gases Xgard Xgard Type 1: Xgard Type 2: Xgard Type 3: Xgard Type 4: Xgard Type 5: Xgard Type 6: Xsafe: Intrinsically safe toxic and oxygen gas detector Flameproof

More information

Toxic Gas Detection. Model F12. Toxic Gas Detection

Toxic Gas Detection. Model F12. Toxic Gas Detection Toxic Gas Detection Model F12 Toxic Gas Detection Smart Sensor Technology The Series F12 Gas Transmitter is an Intrinsically Safe (IS) version of our explosion-proof D12 transmitter. In its standard form,

More information

Warranty Registration

Warranty Registration WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free from defects in workmanship and materials for a period

More information

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases DETECTION DE GAZ FIXE OLCT Detection of Combustible, Toxic or Oxygen gases Infrared XP version SIL 2 high reliability IP 66 Aluminium or Stainless Steel version Certifications Better detection. Better

More information

Product Selection Guide Fixed Gas Detection Systems for Personnel & Equipment Safety

Product Selection Guide Fixed Gas Detection Systems for Personnel & Equipment Safety Product Selection Guide Fixed Gas Detection Systems for Personnel & Equipment Safety GDS Corp gas monitors, controllers and sensors satisfy today s needs for safety and reliability in critical gas detection

More information

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications Sensepoint The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a high quality, low cost solution to their industrial gas monitoring needs. Sensepoint Fit For Purpose Flammable,

More information

Choosing the best detection technologies for measuring combustible gas and VOC vapors

Choosing the best detection technologies for measuring combustible gas and VOC vapors Choosing the best detection technologies for measuring combustible gas and VOC vapors gas an oxygen sensor responds to is oxygen. Electrochemical sensors designed to measure a particular gas may not be

More information

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots 5 Operating Modes GX-6000 Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots GX-6000 5 Operating modes Normal Leak Check Inert Bar hole Snap Log Monitor up to

More information

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots 5 Operating Modes GX-6000 Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots CONFINED SPACE ENTRY Monitor LEL, O2, CO, and H2S Internal sample pump Pull samples

More information

ESD3000 ESD200 Combustible / Toxic Gas Detector

ESD3000 ESD200 Combustible / Toxic Gas Detector ESD3000 ESD200 Combustible / Toxic Gas Detector Combustible and toxic gas leakage inspection instrument in industrial application Ex-proof certificate Exd ⅡC T6 Gb/Ex d ib ⅡC T6 Gb Dust Ex-proof certificate

More information

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ] ULTIMA XL/XT Series Gas Monitors [ Ultimate Features Extreme Design ] Cost effective fixed installation gas monitors with HART Field Communications Protocol. Single-sensor units use catalytic, electrochemical

More information

Model D12. Digital Gas Transmitter

Model D12. Digital Gas Transmitter Model D12 Digital Gas Transmitter Gas detection systems come in all shapes and sizes. Some require simple 4-20 ma transmission. Some are better suited to local alarm relay functions. Some really require

More information

Carbon Monoxide (CO) Gas Detector March 15 GCO 300

Carbon Monoxide (CO) Gas Detector March 15 GCO 300 GCO Carbon Monoxide (CO) Gas Detector March 15 Features Output 4-20 ma or 2-10 Vdc Power supply 24 Vdc Ranges 0-100 ppm or 0-300 ppm IP65 enclosure with quick locking screws Digital measurement value processing

More information

GAS DETECTOR ST400EC PART.NO

GAS DETECTOR ST400EC PART.NO DATA SHEET 1(7) GAS DETECTOR ST400EC PART.NO. 004461-004467 DETECTION OF TOXIC GASES AND OXYGEN SYSTEM GS5000, GS3000, SW2020, BUCONTROL / BUTOUCH GENERAL DESCRIPTION Detection of toxic gases and Oxygen

More information

GAS DETECTION. Parking Garage Guide

GAS DETECTION. Parking Garage Guide GAS DETECTION Parking Garage Guide Building owners and facility managers want to provide safe and effective parking garages while minimizing the energy costs associated with heating, ventilation and air

More information

Gas Detection. - Disposable - Serviceable. Single Gas Detectors

Gas Detection. - Disposable - Serviceable. Single Gas Detectors Gas Detection Single Gas Detectors Introduction Portable single gas detectors are used for personal protection and have the ability to detect a single gas hazard. Typically they are small, lightweight

More information

ESD500. ESD500 Combustible / Toxic Gas Detector

ESD500. ESD500 Combustible / Toxic Gas Detector ESD500 ESD500 Combustible / Toxic Gas Detector Combustible and toxic gas leakage inspection instrument in industrial application Ex-proof certificate Exd ⅡC T6 Gb/Ex d ib ⅡC T6 Gb Dust Ex-proof certificate

More information

Thank You for Attending Our February Webinar:

Thank You for Attending Our February Webinar: 800-953-7626 www.lesman.com/train Thank You for Attending Our February Webinar: Wireless Gas Detection to Enhance Your Existing Safety Strategies Your Host Mike DeLacluyse President Lesman Instrument Co

More information

Frequently Asked Questions

Frequently Asked Questions 1. 2. What advantages does the GT3000 have over the C7064? Hot swappable GTS sensor module is intrinsically safe and allows live maintenance under power Supports HART communication Supports local, one-person

More information

KAE Gas Alarm Operation Manual

KAE Gas Alarm Operation Manual KAE Gas Alarm Operation Manual Henan Hanwei Electronics Co.,Ltd ISO9001-2008 Precautions: To avoid personal safety injury, Instrument damage and potential dangerous accident; do not use gas detector before

More information

Model D12-IR. Digital Gas Transmitter...

Model D12-IR. Digital Gas Transmitter... Model D12-IR Digital Gas Transmitter... ATI s Series D12 gas transmitter line now includes a versatile Infrared system that can be configured for LEL or select toxic gases. The D12-IR utilizes a compact

More information

GL-CO-RFG Channel Gas Leak Alarm System

GL-CO-RFG Channel Gas Leak Alarm System Four Elms Road Edenbridge Kent TN8 6AB UK Features & Benefits Remote sensors for natural gas, LPG and CO 1 x SPST relay outputs DIN-rail as standard, panel mounting kit available Adjustable alarm thresholds

More information

Carbon Monoxide (CO) Gas Detector, 4-20mA GCO. Automatikprodukter. Oct. 15. Features. Technical Data. Design Features. Application.

Carbon Monoxide (CO) Gas Detector, 4-20mA GCO. Automatikprodukter. Oct. 15. Features. Technical Data. Design Features. Application. 300 Features Digital measurement value processing incl. temperature compensation Internal function control with integrated hardware watchdog Data / measured values sensor controller, therefore simple exchange

More information

GasSens. Self Checking Gas Sensors. Modular Gas Detector... Gas & Range Availability

GasSens. Self Checking Gas Sensors. Modular Gas Detector... Gas & Range Availability GasSens Modular Gas Detector... Self Checking Gas Sensors GasSens is a flexible component system providing a variety of options to meet individual gas detection and alarm requirements. From chemical and

More information

Sensepoint. The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a low cost solution to their gas monitoring needs.

Sensepoint. The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a low cost solution to their gas monitoring needs. Sensepoint The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a low cost solution to their gas monitoring needs. Sensepoint One-Stop Shop Flammable, toxic and oxygen versions

More information

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring. Water Quality Labo- Soil/ Soil/ Sedi- Sam- & Air / Dust Toxic gases are present in a wide variety of industrial and civil installations and their detection and monitoring is crucial for the safe working

More information

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS INSTALLATI AND OPERATING INSTRUCTIS PRODUCTS CMD Series CO Detectors FGD Series Refrigerant Detectors AGD Series Toxic Gas Detectors CGD Series Combustible Gas Detectors (All transmitters are factory set

More information

ALTAIR 5X Multigas Detector Product Specification

ALTAIR 5X Multigas Detector Product Specification ALTAIR 5X Multigas Detector Product Specification PHYSICAL CHARACTERISTICS Gas delivery Size, pumped unit without IR Size, pumped unit with IR Weight Handling Case material Environmental protection Display

More information

incontrol Systems Inc. Flame and Gas Detection

incontrol Systems Inc. Flame and Gas Detection incontrol Systems Inc. Flame and Gas Detection Our flame and gas detectors are globally certified to the latest product approval standards Wherever toxic or combustible gases are part of an industrial

More information

Explosion protection Marijan Gorše, dipl. ing.

Explosion protection Marijan Gorše, dipl. ing. Explosion protection Marijan Gorše, dipl. ing. 1/18 Flammable Gas Atmosphere We Can Control Them Explosion hazards mostly arise from flammable gases and vapours. Instead of avoiding their ignition by explosion

More information

Carbon Monoxide CO Transmitter ADT-X3-1110

Carbon Monoxide CO Transmitter ADT-X3-1110 Page 1 Sep. 2017 CO transmitter including digital measurement value processing and temperature compensation for the continuous monitoring of the ambient air to detect carbon monoxide concentrations (CO).

More information

ia d ATEX 100 II 2G D MT 99 ATEX G 001 x EX-METER II Series [ Versatility in Explosive Atmospheres]

ia d ATEX 100 II 2G D MT 99 ATEX G 001 x EX-METER II Series [ Versatility in Explosive Atmospheres] II 2G EEx ia d ATEX 100 D MT IIC T6 99 ATEX G 001 x Series [ Versatility in Explosive Atmospheres] [ The flexible solution for all your needs] After accidents with hazardous material the will provide reliable

More information

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications Sensepoint The Sensepoint range of flammable, toxic and Oxygen gas detectors offer users a high quality, low cost solution to their industrial gas monitoring needs. Sensepoint Fit For Purpose Flammable,

More information

Leak detector for refrigerant gases R22, R134a, R410A, R407C...

Leak detector for refrigerant gases R22, R134a, R410A, R407C... PCE-GA3 PCE-LD 1 PCE-GA 70 Pen-sized flammable gas detector Leak detector for refrigerant gases R22, R134a, R410A, R407C... CO2 detector with data logger and software This pen-sized flammable gas detector

More information

Why Wireless Gas Detection?

Why Wireless Gas Detection? Why Wireless Gas Detection? Technologies Coming of Age Standards Certification Education & Training Publishing Conferences & Exhibits Presenter Channing Reis Director of Functional Safety Technologies

More information

Gas Detection division of Arjay Engineering. Gas Detection Maintenance Facilities Parking Garages Warehouses. EN-GD-11a

Gas Detection division of Arjay Engineering. Gas Detection Maintenance Facilities Parking Garages Warehouses. EN-GD-11a Gas Detection division of Arjay Engineering Gas Detection Maintenance Facilities Parking Garages Warehouses EN--11a A Company from Strong Roots The Enmet Canada series of gas detection is a product division

More information

Monitores Personales. Personal Monitor

Monitores Personales. Personal Monitor Monitores Personales Personal Monitor Micro IV Full Featured Personal Monitor Micro IV Single-gas Detector Highly configurable smart sensor design Wide range of sensors including O 2, H 2 S, CO, NH 3,

More information

MSA Gas Detection. for the Water and Wastewater Industries. Does your facility meet NFPA 820?

MSA Gas Detection. for the Water and Wastewater Industries. Does your facility meet NFPA 820? MSA Gas Detection for the Water and Wastewater Industries Does your facility meet NFPA 820? www.msagasdetection.com A Passion for Safety MSA s passion for safety comes from almost a full century of manufacturing

More information

Recalibrate the way you look at gas detection

Recalibrate the way you look at gas detection Catalogue Gas detection solution Recalibrate the way you look at gas detection Next generation gas detection for industrial refrigeration The next generation of Danfoss gas detectors are based on a digital

More information

AT-G-SENSE Gas Sensing System

AT-G-SENSE Gas Sensing System AT-G-SENSE Gas Sensing System INSTALLATION & OPERATING MANUAL INTRODUCTION The AT-G-SENSE is a system that combines sensor and monitoring features in an integrated unit. It is a stand-alone system used

More information

APPLICATION DATA SHEET

APPLICATION DATA SHEET APPLICATION DATA SHEET S p e c i f i c a t i o n WWW.-..UK Control Systems Transmitters Sensors Accessories TOCSIN 700 D e t e c t o r C o n t r o l P a n e l Wall mounting 24V DC or 110/230vAC operation

More information

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012 Confined Space Monitoring Leak Investigation 1 Functions 4 Bar Hole Sampling Line Purge Testing Actual Size GX-2012 3 Operating Modes Internal sample draw pump with 50 range Low flow alarm 3 bright visual

More information

ALTAIR 5X Multigas Detector

ALTAIR 5X Multigas Detector ALTAIR 5X Multigas Detector With MSA XCell Sensor Technology IT S WHAT S INSIDE THAT COUNTS Now with advanced PID for VOC Detection Because every life has a purpose IT S WHAT S INSIDE THAT COUNTS WORKERS

More information

up to 1.2 m or 3.9 ft. deep). So if you drop the Honeywell BW Ultra in a vat or take it into a dust-prone environment,

up to 1.2 m or 3.9 ft. deep). So if you drop the Honeywell BW Ultra in a vat or take it into a dust-prone environment, BW ULTRA User-Friendly Portable Five-Gas Detection in Confined Spaces Designed specifically for sampling and monitoring confined spaces, before and after entry, Honeywell BW Ultra offers enhanced sensor

More information

GAS DETECTION SYSTEMS

GAS DETECTION SYSTEMS GAS DETECTION SYSTEMS GAS DETECTION SYSTEMS Contents Introduction 3 Introduction to Gas Detection Systems 3 Introduction to the Gas Sense System 3 Where to Install a Gas Detector 4 When to Test the Detector

More information

Gas Central with built-in Gas Detector for Nitrogen Dioxide (NO 2

Gas Central with built-in Gas Detector for Nitrogen Dioxide (NO 2 Features Integrated (built-in NO2 sensor / detector (Electro chemical sensor type Measuring ranges 0-10 ppm, 0-20 ppm or 0-30 ppm LCD display to show actual in ppm Status LED indication Normal operation

More information

Carbon Monoxide (CO) Gas Detector, 4-20mA or 2-10Vdc

Carbon Monoxide (CO) Gas Detector, 4-20mA or 2-10Vdc Wall Features Digital measurement value processing incl. temperature compensation Internal function control with integrated hardware watchdog Data / measured values sensor controller, therefore simple

More information

MGS-350 Gas Detector Installation and Operation Manual Instruction Revision 1 February 2013 Product Leadership Training Service

MGS-350 Gas Detector Installation and Operation Manual Instruction Revision 1 February 2013 Product Leadership Training Service MGS-350 Gas Detector Installation and Operation Manual Instruction 6509-9000 Revision 1 February 2013 Product Leadership Training Service Reliability WARRANTY POLICY BACHARACH, INC. WARRANTS THIS INSTRUMENT,

More information

Sensepoint XCL. Gas Detection. Fixed Gas Detector FEATURES & BENEFITS. Flexible Output Options. Visual Integration. Faster Installation

Sensepoint XCL. Gas Detection. Fixed Gas Detector FEATURES & BENEFITS. Flexible Output Options. Visual Integration. Faster Installation Sensepoint XCL Fixed Gas Detector Gas Detection Sensepoint XCL is a fixed point gas leak detector that is designed to meet the needs of commercial and light industrial applications. With over 50 years

More information

MultiRAE Lite. Wireless Portable Multi-Gas Monitor

MultiRAE Lite. Wireless Portable Multi-Gas Monitor MultiRAE Lite Wireless Portable Multi-Gas Monitor The MultiRAE Lite is an optimal one-to-six 4 -gas monitoring solution for personal protection (including confined space entry) and multi-gas leak detection

More information

G-TECTA TM. Portable Gas Detection Instruments

G-TECTA TM. Portable Gas Detection Instruments G-TECTA TM Portable Gas Detection Instruments 2 Why Linde gas detection? The Linde Group is a global leader in the supply of gases, we provide expertise and product solutions to industry, commerce, science

More information

SAFETY AND MAINTENANCE TIPS FOR NATURAL GAS USERS FROM THE VILLAGE OF DIVERNON

SAFETY AND MAINTENANCE TIPS FOR NATURAL GAS USERS FROM THE VILLAGE OF DIVERNON SAFETY AND MAINTENANCE TIPS FOR NATURAL GAS USERS FROM THE VILLAGE OF DIVERNON Natural gas is a one of the safest fuels. Composed mostly of methane, it is naturally colorless and odorless. For safety s

More information

GAS DETECTION SYSTEMS

GAS DETECTION SYSTEMS Contents Introduction 3 Introduction to Gas Detection Systems 3 Introduction to the Gas Sense System 3 Where to Install a Gas Detector 4 When to Test the Detector 5 Gas Test Concentration 5 Gas Sense Detectors

More information

GG-LEL2 COMBUSTIBLE GAS SENSOR. Installation and Operation Manual

GG-LEL2 COMBUSTIBLE GAS SENSOR. Installation and Operation Manual GG-LEL2 COMBUSTIBLE GAS SENSOR Installation and Operation Manual 2 GG-LEL2 Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified by Calibration

More information

GASBLASTER LSX4 OPERATION MANUAL

GASBLASTER LSX4 OPERATION MANUAL GASBLASTER LSX4 OPERATION MANUAL 2 The treatment and transfer of wastewater produces odor emissions what are sometimes disturbing for the population living nearby a waste treatment facility or pumping

More information

DESIGN MANUAL MODEL GIR900 INFRARED COMBUSTIBLE GAS SENSOR

DESIGN MANUAL MODEL GIR900 INFRARED COMBUSTIBLE GAS SENSOR DESIGN MANUAL MODEL GIR900 INFRARED COMBUSTIBLE GAS SENSOR 70086 The information in this doucment is applicable to sensors built in September, 2008 or later (Firmware 3.0) The information and technical

More information

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control. Détecteur de gaz OLCT80 Detectors-Transmitters for Flammable, Toxic Gases and Oxygen Non-intrusive operation via intrinsically safe infrared remote control Disponible en version déportée, ADF ou de SI

More information

Installation and Wiring 1.

Installation and Wiring 1. Installation and Wiring 1. Please read the Security Notifications in detail firstly. 2. The gas detector might install on wall or steel plate, please refer following drawing to make marking then drill

More information

GS100M Gas Detection Controller

GS100M Gas Detection Controller GS100M Gas Detection Controller GS100M 1 Zone Gas Detection Controller 1 Zone / Sensor Conventional Positive Safety IP44 EN61010-1 EN50270 FEATURES Single Zone Protection Positive Safety Option Detection

More information

Safe Operation Manual. Honeywell IQ Force Gas Detector

Safe Operation Manual. Honeywell IQ Force Gas Detector Safe Operation Manual Honeywell IQ Force Gas Detector Honeywell Analytics 800-663-4164 403-248-9226 Fax 403-575-3708 03JUN2012 P/N 50105843-047 Version 01 http://www.honeywell.com HONEYWELL IQ Force PERSONAL

More information

Fixed Gas & Flame Detection International Product Range Overview

Fixed Gas & Flame Detection International Product Range Overview Fixed Gas & Flame Detection International Product Range Overview Over 100 years of experience and capability in comprehensive safety solutions have made MSA a modern and forward-looking company for the

More information

Operation and Maintenance Manual

Operation and Maintenance Manual Operation and Maintenance Manual GDS-48 Remote Bridge Sensor for Combustible Gases AUTHORIZED DISTRIBUTOR: GasDetectorsUSA.com - Houston, Texas USA sales@gasdetectorsusa.com - 832-615-3588 CAUTION: FOR

More information

AT-G-SENSE Gas Sensing System

AT-G-SENSE Gas Sensing System AT-G-SENSE Gas Sensing System INSTALLATION & OPERATING MANUAL INSTALLATION INSTRUCTIONS Open the AT-G-SENSE by undoing the two screws. Remove metal faceplate, turn over and check connection terminals (maximum

More information

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM User Instructions For The Model 5200 Gas Monitor System To completely customize the specifications to your exact application, modifications to the following

More information

MSA Flame and Gas Detection. [ for the Oil, Gas and Petrochemical Industries ]

MSA Flame and Gas Detection. [ for the Oil, Gas and Petrochemical Industries ] MSA Flame and Gas Detection [ for the Oil, Gas and Petrochemical Industries ] A PASSION FOR SAFETY MSA s passion for safety comes from almost a full century of manufacturing the best-of-breed, highest-quality

More information

P R O D U C T D ATA S H E E T

P R O D U C T D ATA S H E E T PGF- Effective Gas Safety Proving and Gas Detection Controller Gas Pressure Proving For use with Natural Gas LPG - or Laboratory gas supplies, both high and low pressure ensuring system integrity prior

More information

Combustible and Toxic Gas Detection Solutions. Performance and Safety Beyond Compliance

Combustible and Toxic Gas Detection Solutions. Performance and Safety Beyond Compliance Combustible and Toxic Gas Detection Solutions Performance and Safety Beyond Compliance Reliable Solutions from Det-Tronics, Your Partner in Safety Trusted Response with the Utmost Confidence Our proven

More information

P R O D U C T D ATA S H E E T

P R O D U C T D ATA S H E E T Keyless RFID Control PGF- Effective Gas Safety Proving and Gas Detection Controller RFID Gas Proving, Ventilation Control & Gas Detection, off one panel Our range of gas proving systems can be used for:

More information