N2MVF Series Compact Fluorescent

Similar documents
LMV Series W Low Profile - Medium Base

EVLPF Series Compact Fluorescent

DMV Series W For Combustible Dusts

Applications. Standard Materials

VAPORGARD Incandescent Luminaires

UL Listed Available with Cl. I, Div. 2, Groups A, B, C, D rating

Table 500-3(d) Identification Numbers. Maximum Identification

Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications. Now cul Listed!

elevated ambient capability. in installations where moisture, dirt, dust, vibration, corrosion and rough usage are problems.

EVLED201 36W Led Luminaire. Descriptions. Manufacturer Information. Packaging Carton 1 Weight Per each 14.85

Champ-Pak Wall Pack Luminares

Hazardous Area LED Lighting Hazard Gard LED Luminaires. Hazard Gard EVLL LED

Champ-Pak TM Wall Pack & Floodlight Luminaires Hazardous and Non-Hazardous

Enhancing Safety + Productivity. Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications

50-175W VMV Series Champ H.I.D. Luminaires

Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications. Now cul Listed!

Enhancing Safety + Productivity. Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications

Engineering Safety & Productivity. Champ FMV LED Series Floodlight Fixtures Leading the way in LED technology for harsh and hazardous area usage

Pro Series LED Lighting Champ LED floodlights. Champ Pro Series. LED floodlights for heavy industrial

Engineering Safety & Productivity. Champ FMV LED Series Floodlight Fixtures Leading the way in LED technology for harsh and hazardous area usage

4' 2 Lamp Fluorescent Light Fixture - Emergency Battery Backup - T8 Bulbs - Multi-voltage - CID2

UTILITY LIGHT INTRODUCTION

Hazardous Area LED Light -Class 1 Div 2 Groups A, B, C, D and Class 2 Div 2 F,G - 4' 4 lamp

CEC: Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Enclosure 4X

HID lighting for hazardous areas Champ HID floodlighting. Champ floodlights. HID floodlighting for hazardous areas

MAR2 LED SERIES M A R 2 L E D. Linear LED Lighting for Hazardous Locations

An Eaton Intelligent Power solution. Champ VMV Connected lighting for hazardous areas

50W Explosion Proof LED Light - C1D2, C2D1 - Replacement for 150W Metal Halide - Globe/Guard

COMPACT SIZE INTRODUCTION & LOGIC

Explosion Proof Light Watt Metal Halide - Class 1 Div 1 & Class 2 Div 1

EJB Custom-Built Control Panels

Code Master Factory Sealed Strobe Luminaires Explosionproof, Dust-Ignitionproof

V2LCHF2UNV1 Led Lumnr. Features. Material, Color, and Finish. Long Description. Manufacturer Information EATON CROUSE-HINDS SERIES GTIN

48W Fluorescent T8 Light w/ Emergency Backup Dimmable Ballast - (2) 2 Foot T8 Lamps - C1D2

REDUCED PROFILE INTRODUCTION

LED lighting for land-based rigs Pauluhn DLL LED Luminaires. Pauluhn DLL. LED luminaires for land-based drilling

EXH Series Explosionproof Electric Air Heaters

Explosion Proof LED Strobe Light - 4Hz Flash Rate - 10 Watts - Class I, Div. I - IP67

Class 1 Div 2 LED Pivoting Light - 2 foot 2 lamp - LED T series Style V Dimmable

WARNING WARNING. Installation Instructions for 116DEXSTC-FJ AdaptaBeacon Fire Alarm Strobe Lights for Use in Hazardous Locations.

*RENTAL* Class 1 Division Watt Incandescent Light - Explosion Proof - Wall Mount Volts

Hazardous Location LED String Lights - 5 Jelly Jar Lamps - Non Metallic - Chemical Resistant - CID2

Installation Instructions for 116EXMLED Series AdaptaBeacon LED Lights for Use in Hazardous Locations. Description. Installation WARNING

Hazardous Location LED Pivoting Light - C1D2 - Dimmable - Modbus TCP/IP Network - Meets USCG Specs

Explosion Proof Emergency Fluorescent Light Combination - Dimmable Ballast - C1D1-2 T8 lamps - 4'

25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL

Explosion Proof UV/Visible Light Fluorescent Fixture - Paint Spray Booth, Rigs - Two Circuit Lamps

Hazardous area LED lighting Vaporgard LED Luminaires. Vaporgard LED. Low profi le incandescent replacement

80W C1D2 Hazardous Location Integrated LED - Corrosion Resistant for Marine - Emergency Backup

REFRACTOPACK. Corrosion resistant construction allows this luminaire to be installed in corrosive and marine outdoor applications.

Lighting for Hazardous & Severe Environments

NONMETALLIC LIGHT FIXTURES

100W Explosion Proof Low Bay AC LED Fixture - C1D1 - C2D1 - Group B + ATEX/IECEX - IP67 Waterproof

Explosion Proof C1D2 0-10V Dimmable LED Fixture - 4ft 2 Lamp - Emergency Ballast - Terminal Strips

Vaporgard LED Series Leading the way in LED technology for industrial and hazardous applications 25W W LED REPLACES INCANDESCENT

Explosion Proof LED Light - Equivalent to Watt HID C1D2, UL Listed

Explosion Proof LED Light - Equivalent to Watt Metal Halide - Class 1 Division 2

Rating. Class I Div II

5 yr. Vitalite Rotating Warning Light. Models 121 and 121A LIGHT DUTY VEHICULAR LIGHT

LED hazardous lighting catalog

HOLOPHANE. Vector Luminaire. Optimum visibility. Improved highway safety. Outstanding visibility in critical security applications HL /98

Explosion Proof 160 W Class 1 & 2 Fluorescent UV Light With 4 Lamps - Class 1 Division 1

AFTER INSTALLATION DELIVER THIS MANUAL TO OWNER IMPORTANT SAFETY INSTRUCTIONS

MN/DOT Specification Sign Lighting Luminaire With 150 or 250 Watt Metal Halide Lamps 11/05/09

26 Watt Explosion Proof Low Profile LED Fixture - 3,380 Lumens - Class 1 & 2 Div 1 & 2 - ATEX / IECE

50W Explosion Proof Trunnion Mount Compact LED Flood Light - C1D2, C2D1 - Paint Spray Booth Approved

C1D1 Explosion Proof 50W LED Flood Light Fixture - Paint Spray Booth Approved - Adj Surface Mount

The Signal Is Clear TM

C2D1/C1D2 Explosion Proof 50 Watt LED Light Fixture - Paint Spray Booth Approved - 6,250 Lumens

HL-2449_flg:8 pager 6/17/10 11:19 AM Page 1 Tear Drop LED Series

Capella 2. Project Name. Construction. Optical System. Product Applications. Housing and lens frame are constructed from heavy-duty low

XGB Unit Heater. Certification. Model Coding XGB 038 T3B 3 1 T TEMPERATURE CODE T3B (165 C) T3A (180 C) T2D (215 C) T2C (230 C)

Installation Instructions for 116DEGEX-FJ-(R) AdaptaBeacon Fire Alarm Strobe Lights for Use in Hazardous Locations

SIMPLIFIED LIGHTING. TRUSTED PROTECTION. CODE MASTER LED LUMINAIRES CLASS I, DIVISION 1

MERCMASTER LED SERIES

Explosion Proof LED String Lights - 5 Hand Lamps - Class 1 & Class 2

E THANOL AND B IODIESEL P LANT L IGHTING S OLUTIONS

STI-1229-HAZ STI-1229HTR-HAZ STI-1229HTR240-HAZ

56W Hazardous Location LED Fixture - C1D2 - Stainless Steel - Dimmable - DALI Network

HOLOPHANE. Vector Luminaire. Optimum visibility. Improved highway safety. Outstanding visibility in critical security applications HL /98

Certificate of Compliance

150W Explosion Proof High Bay LED Light Fixture - C1D1&2 - C2D1&2-17,500 Lumens - 60 Beam

CATALOG NUMBER NAME DESCRIPTION HTL X Keeper 2 40 Watts 120v 5000K 4,000 Lm HTL X Keeper 2 40 Watts 277v 5000K 4,000 Lm 4.

SECTION EXTERIOR LIGHTING

LED lighting for light industrial areas IHB series high bay LED luminaires. IHB series. High bay LED luminaires for light industrial areas

56W Hazardous Location LED Light - C1D2 - Corrosion Resistant for Marine - Dimmable - DALI Network

POLESTAR II SERIES HL /01

DHL-LP-LED Low Profile LED Linear High/Low Bay

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

FX5 Series Explosion-Proof Electric Air Heaters

60W Flameproof LED Emergency Linear Fixture V AC - (2) 30W LED Lamps - ATEX/IECEx

Class 1 Division 2 Hazardous Location Stack Light - Signal Traffic Light - Multiple Lamp Colors

208W Explosion Proof Low Profile LED - Emergency Backup - 27,040 Lumens - C1&2 D1&2 - ATEX /IEC

Petrolux III. PW Series Wet Locations

POINT ROLLOVER LIGHTS PRL LED HELIDECK SEMIFLUSH LIGHT

STYLISH SOLUTIONS FOR OUTDOOR AND INDOOR SPACES

Choice of factory set distributions. Thermally set white polyester powder paint. Optional wet location listing

Explosion-Proof Forced Air Unit Heater - XGB

Explosion-Proof Forced Air Unit Heater - XGB

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR PIPE THREAD IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

Transcription:

Cl. I, Div. 2, Groups A, B, C, D Cl. II, Groups F, G Cl. III & Simultaneous Presence Marine & Wet Locations, R, 4, 4X; IP56 Applications: Champ Luminaires are used: In areas in which ignitable concentrations of flammable gases or vapors will be present due to abnormal, unusual or accidental conditions In installations where moisture, dirt, vibration, corrosion, or rough usage are concerns Wherever the damaging effects of water, wind, snow, sleet, hot sun, or any combination of these elements are found Ideal for marine use; resists the harmful effects of salt water Withstands the harshest of corrosive environments To provide low wattage spot and floodlighting For general area lighting In manufacturing plants, refineries, chemical, petrochemical and other industrial process facilities, wastewater and sewage treatment facilities, offshore, dockside, and harbor installations as well as other heavy industrial applications Features and Benefits: Housings and mounting modules made of polyphenylene sulfide (PPS) for strength and maximum resistance to corrosion Pendant mounting module equipped with integral hub set screws for vibration resistance Hubs are provided with an integral bushing to help prevent damage to field wiring during installation and ground connection for positive bonding Guard, hub inserts, stanchion elbow, and hardware made of stainless steel for maximum resistance to corrosion Grounding wire for safety Stainless steel open bottom guard permits direct access to the globe for easy relamping Hinged assembly allows the luminaire to hang free during installation to permit the use of both hands when wiring One external captive screw for ease of installation Handle hinge assembly doubles as a handle for ease of installation, especially when carrying up a ladder Additional Features: Fluorescent Energy Savings Less wattage used with compact fluorescent lamps compared to equivalent incandescent lamps providing the same light output Certifications and Compliances: NEC and CEC: Class I, Division 2, Groups A, B C, D Class II, Class III & Simultaneous Presence (Class I, Division 2 and II) UL Standards: 844 Hazardous (Classified) Locations 1598 Luminaires 1598A Marine Locations CSA Standards: C22.2 No. 17 Standard Materials: Housing, mounting modules polyphenylene sulfide (PPS) Guard, hub inserts, stanchion elbow, hardware stainless steel Globe heat- and impact-resistant, internally fluted glass Gaskets silicone rubber Electrical Ratings: Wattages: Two 26 or 2 watt lamps 120-277V, 50-60Hz 47V, 60Hz 12, 24, and 125 VDC Ordering Information: Mounting Style Pendant Mount Ceiling Mount Thru-Feed Average Luminaire Weight Description Lbs. Body, mounting module, globe, guard, and reflector Standard Voltage Ballasts Optional Ballasts NEC/UL & CEC/CSA (cul) CEC/CSA (cul) Voltage 120 277V 50 60Hz 47V 60Hz 125V DC 12V DC 24V DC Suffix /UNV /47 /125VDC /012VDC /024VDC Temperature Performance Data: Minimum Operating Temperature Hub Size in. Maximum Ambient Temp. Options: Description Suffix Wall-Mount Arm For converting a ceiling-mount luminaire to a wall mount... N2MV-WM1 Factory Assembled For a factory assembled luminaire with lamps installed... FA Fusing To protect ballast against abnormal line conditions (not suitable for marine applications)... S658 Furnished with s... S714 Teflon Coated Globe Provides additional protection against shattered glass fragments when subject to thermal shock, etc.... S808 Class I Non-restricted Breathing With G0 Globe and P Guard Cat. # /4 52 N2MVF2A052GP 1 N2MVFA052GP /4 64 N2MVF2A064GP 1 N2MVFA064GP /4 52 N2MVF2C052GP 1 N2MVFC052GP /4 64 N2MVF2C064GP 1 N2MVFC064GP Stanchion Mount 1 1 /2 52 N2MVFJ052GP 25 Angle 1 1 /2 64 N2MVFJ064GP Class II Fluorescent: N2MVF Division 2 Division 1 52 & 64 Watt 18 C (0 F) 40 C (104 F) T2D T4 85 Supply Wire C 0 1078 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 201 Eaton s Crouse-Hinds Business

- Ordering by Components N2MVF Luminaires are available in components. A complete luminaire consists of: I. N2MV Cover (Mounting Module) II. N2MV Ballast Housing III. Globe, Refractors, Guards, Reflectors I. N2MV Cover (Mounting Module): Type Conduit Cat. # Pendant /4" N2APM2 1" N2APM Ceiling /4" N2CM2 1" N2CM Wall (Use wall bracket /4" N2MV WM1 and N2CM2 accessory with Ceiling Cover) 1" N2MV WM1 and N2CM Stanchion 25 Degree Angle 1 1 /2" N2JM5 II. Ballast Housings: Complete catalog number must have the voltage suffix (UNV shown) and any options suffixes. Type Cat. # 2 (26W) N2MVF052/UNV 2 (2W) N2MVF064/UNV III. Globe, Guards, and Reflectors: Type Cat. # Globe Globe Teflon Coated Globe Guard Reflector Dome Reflector Angle G0 G0S808 P RD79 RA79 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 201 Eaton s Crouse-Hinds Business 1079

Family Tree A complete luminaire consists of a cover mount, a ballast housing and a globe, with or without guard, refractor or reflector. All Components are suitable for use in ordinary locations, Class I, Div. 2 and wet locations. 1080 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 201 Eaton s Crouse-Hinds Business

Dimensions Weights Dimensions In Inches: Pendant Mount Ceiling Mount Top View 25 Angle Stanchion Mount Ceiling Mount Net Luminaire Weights: Luminaire Series N2MVF052 52 0 N2MVF064 64 0 Luminaire with Mounting Module, Globe, Guard & Refractor (lbs.) Accessories: Reflectors (to be used with globe) Type Cat. # Dome RD79 (RD79) 0 Angle RA79 (RA79) To be ordered separately. Wall Arm Mount www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 201 Eaton s Crouse-Hinds Business 1081

Photometric Data N2MVF Photometric Data Isofootcandle Chart: Luminaire with globe and dome reflector N2MVF064GRD Dome Reflector Note: For 52 watt N2MVF applications, use a.75 multiplier. Footcandle Values for Isofootcandle Lines Mounting Height A B C D E 8' 4.00 2.00 1.00 0.50 0.25 10' 2.56 1.28 0.64 0.2 0.16 12' 1.78 0.89 0.44 0.22 0.11 16' 1.00 0.50 0.25 0.1 0.06 N2MVF064GRD Dome Reflector Coefficients of Utilization Effective Floor Cavity Reflectance 20% Room Cavity Ratio Eff. Ceil. Wall 1 2 4 5 6 7 8 9 10 80* 70* 50* 0* 50*.741.617.524.452.96 0*.694.548.445.70.14 10*.652.491.82.08.254 50*.722.601.510.440.86 0*.679.57.47.64.09 10*.640.48.78.05.252 50*.686.570.484.418.67 0*.650.516.421.51.299 10*.617.470.69.299.247 50*.65.542.460.98.50 0*.62.497.406.40.290 10*.596.457.61.29.24 50*.622.516.47.79. 10* 0*.598.478.92.29.271 10*.576.444.52.287.29 0* 0*.557.424.2.267.220 *Percent Reflectance..51.14.28.258.26.271.27.210.188.169.214.18.159.140.125.42.07.277.252.21.267.24.207.185.167.212.182.158.19.124.26.29.265.242.22.259.227.202.181.16.209.180.155.18.12.11.280.254.2.214.251.221.197.176.160.206.177.154.16.121.297.268.244.224.206.244.215.192.172.156.20.175.152.15.120.184.157.16.119.105 1082 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 201 Eaton s Crouse-Hinds Business