EVLPF Series Compact Fluorescent

Similar documents
LMV Series W Low Profile - Medium Base

N2MVF Series Compact Fluorescent

DMV Series W For Combustible Dusts

UL Listed Available with Cl. I, Div. 2, Groups A, B, C, D rating

EVLED201 36W Led Luminaire. Descriptions. Manufacturer Information. Packaging Carton 1 Weight Per each 14.85

Table 500-3(d) Identification Numbers. Maximum Identification

Hazardous Area LED Lighting Hazard Gard LED Luminaires. Hazard Gard EVLL LED

VAPORGARD Incandescent Luminaires

Applications. Standard Materials

elevated ambient capability. in installations where moisture, dirt, dust, vibration, corrosion and rough usage are problems.

Champ-Pak Wall Pack Luminares

EJB Custom-Built Control Panels

Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications. Now cul Listed!

Champ-Pak TM Wall Pack & Floodlight Luminaires Hazardous and Non-Hazardous

50W Explosion Proof LED Light - C1D2, C2D1 - Replacement for 150W Metal Halide - Globe/Guard

50-175W VMV Series Champ H.I.D. Luminaires

Explosion Proof LED Strobe Light - 4Hz Flash Rate - 10 Watts - Class I, Div. I - IP67

4' 2 Lamp Fluorescent Light Fixture - Emergency Battery Backup - T8 Bulbs - Multi-voltage - CID2

Hazardous Area LED Light -Class 1 Div 2 Groups A, B, C, D and Class 2 Div 2 F,G - 4' 4 lamp

Code Master Factory Sealed Strobe Luminaires Explosionproof, Dust-Ignitionproof

HID lighting for hazardous areas Champ HID floodlighting. Champ floodlights. HID floodlighting for hazardous areas

Enhancing Safety + Productivity. Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications

Pro Series LED Lighting Champ LED floodlights. Champ Pro Series. LED floodlights for heavy industrial

Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications. Now cul Listed!

48W Fluorescent T8 Light w/ Emergency Backup Dimmable Ballast - (2) 2 Foot T8 Lamps - C1D2

Explosion Proof Light Watt Metal Halide - Class 1 Div 1 & Class 2 Div 1

Class 1 Div 2 LED Pivoting Light - 2 foot 2 lamp - LED T series Style V Dimmable

Lighting for Hazardous & Severe Environments

COMPACT SIZE INTRODUCTION & LOGIC

V2LCHF2UNV1 Led Lumnr. Features. Material, Color, and Finish. Long Description. Manufacturer Information EATON CROUSE-HINDS SERIES GTIN

Engineering Safety & Productivity. Champ FMV LED Series Floodlight Fixtures Leading the way in LED technology for harsh and hazardous area usage

LED lighting for land-based rigs Pauluhn DLL LED Luminaires. Pauluhn DLL. LED luminaires for land-based drilling

Engineering Safety & Productivity. Champ FMV LED Series Floodlight Fixtures Leading the way in LED technology for harsh and hazardous area usage

25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL

26 Watt Explosion Proof Low Profile LED Fixture - 3,380 Lumens - Class 1 & 2 Div 1 & 2 - ATEX / IECE

EXH Series Explosionproof Electric Air Heaters

Enhancing Safety + Productivity. Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications

Explosion Proof UV/Visible Light Fluorescent Fixture - Paint Spray Booth, Rigs - Two Circuit Lamps

UTILITY LIGHT INTRODUCTION

Hazardous Location LED Pivoting Light - C1D2 - Dimmable - Modbus TCP/IP Network - Meets USCG Specs

Explosion Proof Emergency Fluorescent Light Combination - Dimmable Ballast - C1D1-2 T8 lamps - 4'

*RENTAL* Class 1 Division Watt Incandescent Light - Explosion Proof - Wall Mount Volts

Explosion Proof Exit Sign - Class I, Division I - IP65-120V/277VAC - Emergency Battery Back-Up

REDUCED PROFILE INTRODUCTION

CATALOG NUMBER NAME DESCRIPTION HTL X Keeper 2 40 Watts 120v 5000K 4,000 Lm HTL X Keeper 2 40 Watts 277v 5000K 4,000 Lm 4.

208W Explosion Proof Low Profile LED - Emergency Backup - 27,040 Lumens - C1&2 D1&2 - ATEX /IEC

Explosion Proof 70 Watt Low Profile LED Light Fixture Lumens - C1D1 Group B - Hydrogen Rated

An Eaton Intelligent Power solution. Champ VMV Connected lighting for hazardous areas

CEC: Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Enclosure 4X

Explosion Proof LED Light - Equivalent to Watt Metal Halide - Class 1 Division 2

80W C1D2 Hazardous Location Integrated LED - Corrosion Resistant for Marine - Emergency Backup

Explosion Proof C1D2 0-10V Dimmable LED Fixture - 4ft 2 Lamp - Emergency Ballast - Terminal Strips

Rating. Class I Div II

Fire Alarm or Emergency Call Points

SIMPLIFIED LIGHTING. TRUSTED PROTECTION. CODE MASTER LED LUMINAIRES CLASS I, DIVISION 1

Hazardous Location LED String Lights - 5 Jelly Jar Lamps - Non Metallic - Chemical Resistant - CID2

Explosion Proof LED Light - Equivalent to Watt HID C1D2, UL Listed

FX5 Series Explosion-Proof Electric Air Heaters

C1D1 Explosion Proof 50W LED Flood Light Fixture - Paint Spray Booth Approved - Adj Surface Mount

C2D1/C1D2 Explosion Proof 50 Watt LED Light Fixture - Paint Spray Booth Approved - 6,250 Lumens

Hazardous area LED lighting Vaporgard LED Luminaires. Vaporgard LED. Low profi le incandescent replacement

Explosion Proof 160 W Class 1 & 2 Fluorescent UV Light With 4 Lamps - Class 1 Division 1

MAR2 LED SERIES M A R 2 L E D. Linear LED Lighting for Hazardous Locations

50W Explosion Proof Trunnion Mount Compact LED Flood Light - C1D2, C2D1 - Paint Spray Booth Approved

5 yr. Vitalite Rotating Warning Light. Models 121 and 121A LIGHT DUTY VEHICULAR LIGHT

150W Explosion Proof High Bay LED Light Fixture - C1D1&2 - C2D1&2-17,500 Lumens - 60 Beam

Vaporproof White LED Light - 10 Watts - Non-Metallic - Corrosion Resistant Lumens

NONMETALLIC LIGHT FIXTURES

Installation Instructions for 116EXMLED Series AdaptaBeacon LED Lights for Use in Hazardous Locations. Description. Installation WARNING

Description. Applications

LED NEW FB-SERIES LED NEW-SF FIXTURE LED NEW-SD FLOODLIGHT LED NEW-SD STREET. LED Explosion-proof Platform Light. LED Tri-proof Light

100W Explosion Proof Low Bay AC LED Fixture - C1D1 - C2D1 - Group B + ATEX/IECEX - IP67 Waterproof

LED lighting for light industrial areas IHB series high bay LED luminaires. IHB series. High bay LED luminaires for light industrial areas

56W Hazardous Location LED Fixture - C1D2 - Stainless Steel - Dimmable - DALI Network

WARNING WARNING. Installation Instructions for 116DEXSTC-FJ AdaptaBeacon Fire Alarm Strobe Lights for Use in Hazardous Locations.

120W Hazardous Location LED Fixture V DC - Modbus TCP/IP - Network Controlled - Dimmable

Stars Management JLT SUBMITTAL. EXPLOSION PROOF ELECTRIC AIR HEATER (FX Series)

Crouse-Hinds Enclosures. High performance, high reliability enclosures for global applications

PANELBOARD PROTECTION ON A GLOBAL SCALE

Low Profile Clean Room 150W LED Light - 2x2 Lay-In Troffer C1D1 - C2D2 - ISO 14644/FS-209E

CF1 ProVector Explosion-Proof Heaters

Bright Ideas. Innovative Solutions. Product Catalog. INDUSTRIAL AND HAZARDOUS Lighting Solutions

LED hazardous lighting catalog

120W Explosion Proof Signal Light w/ Audible Alarm - C1D1 - (2) Colored LED Lamps - 55 Horn Tones

Lighting Solutions. from a Leader in Light Source Technology

Hazardous Area Products

Certificate of Compliance

56W Hazardous Location LED Light - C1D2 - Corrosion Resistant for Marine - Dimmable - DALI Network

Class 1 Division 2 Hazardous Location Stack Light - Signal Traffic Light - Multiple Lamp Colors

Capella 2. Project Name. Construction. Optical System. Product Applications. Housing and lens frame are constructed from heavy-duty low

BC9700 series High Power LED Explosion Proof Light

DuroSite LED High Bay - UL for Indoor and Outdoor Industrial Applications. Patent Pending

CX1 ProVector Explosion-Proof Heaters

Petrolux III. PW Series Wet Locations

AFTER INSTALLATION DELIVER THIS MANUAL TO OWNER IMPORTANT SAFETY INSTRUCTIONS

C1D1 Explosion Proof Horn - Industrial Siren - Programmable Timer - NEMA 4X - Weatherproof

PRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Installation and Maintenance Manual. Model 154XST Series Strobe Light for Use in Hazardous Conditions. français...page 21 español...

HL-2449_flg:8 pager 6/17/10 11:19 AM Page 1 Tear Drop LED Series

Transcription:

EVLPF Series Low Profile Hazard Gard Luminaires Cl. I, Div. 1, Groups B (GB Suffix), C, D Cl. I, Zone 1, Groups IIB + H2 (GB Suffix), IIB, IIA Cl. II, Div. 1, Groups E, F, G Class III, Simultaneous Presence Marine & Wet Locations, R, 4, 4X; IP66 Applications: Eaton's Crouse-Hinds Low Profile Hazard Gard luminaires are used in: Areas where flammable or explosive vapors or gases are present Hazardous areas, both indoors and outdoors, where long life and low maintenance costs are desired Petroleum refineries, chemical, petrochemical and pharmaceutical plants, oil terminals, gas plants and other heavy process industry facilities Waste treatment facilities Drilling platforms and other coastal and offshore hazardous areas Features and Benefits: Small, compact size Two start Acme threaded construction Lightweight copper-free aluminum housing with powdered epoxy finish All exterior hardware is corrosionresistant stainless steel Four mounting arrangements - pendant, ceiling, wall bracket, and stanchion Wide range of light sources and wattages Marine and NEMA 4X construction Integral ballast High power factor (90%+) ballasts Uses same mounting modules as the standard Hazard Gard Internally fluted glass globes Krydon construction dome and angle reflectors won't rust, corrode, dent, chip, or peel Now available in components luminaire body, mounting module, guard, reflectors Three wire construction is standard on fluorescent emergency lighting Perfect where low mounting restrictions are a concern Easier assembly, installation and maintenance Superior corrosion resistance Suit any lighting layout Meet specific lighting needs Outdoor, hose down, marine, and corrosive environments suitable Lowest installed cost Allows more luminaires per circuit Easy retrofitting when the EVLPF is the preferred choice Reduces glare and distributes light evenly ideal for adverse environments typical of industrial facilities Easily stocked for quick ship requirements For energy conservation, luminaires can be switched off without affecting the emergency operation feature Certifications and Compliances: NEC and CEC: Class I, Division 1, Groups B (GB suffix), C, D Class I, Zone 1, Groups IIB + H2 (GB Suffix), IIB, IIA Class II, Class III & Simultaneous Presence (Class I and Class II) UL Standards: 844 Hazardous (Classified) Locations 1598 Luminaires 1598A Marine Locations CSA Standards C22.2 No. 17 Standard Materials: Mounting modules, cover, ballast housing, globe holder copper-free aluminum Globe heat- and impact-resistant glass Exterior hardware stainless steel Reflectors (dome & angle) Krydon fiberglass-reinforced polyester Options: Standard Finishes: Copper-free aluminum Corro-free powdered epoxy Krydon white Stainless steel guard Ratings (Electrical/Size): Sources/Wattage: 52W (two 26W lamps) & 64W (two 2W lamps) 120 277V, 50 60Hz 47V, 60Hz 12, 24, 125 VDC Conduit Entries: /4", 1" NPT Pendant, Wall Bracket, Ceiling 1 1 /4" NPT Stanchion Description Suffix Group B suitability... GB Fused (not suitable for marine applications)... S658 Factory assembled with lamps... FA Accessories: Description Dome reflector... RD79 Angle reflector... RA79 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 201 Eaton s Crouse-Hinds Business 108

EVLPF Series Low Profile Hazard Gard Luminaires Cl. I, Div. 1, Groups B (GB Suffix), C, D Cl. I, Zone 1, Groups IIB + H2 (GB Suffix), IIB, IIA Cl. II, Div. 1, Groups E, F, G Class III, Simultaneous Presence Marine & Wet Locations, R, 4, 4X; IP66 Pendant Wall Bracket* Ceiling* Stanchion Hub Watt Size (In.) Fluorescent High Power Factor Ballast (Min. P.F. 90%) 52W 64W Luminaire Body Less Mounting Module & Guard /4 EVLPFA02521 EVLPFBX02521 EVLPFCX02521 EVLPF0520 1 EVLPFA0521 EVLPFBX0521 EVLPFCX0521 1 1 /4 EVLPFJ04521 /4 EVLPFA02641 EVLPFBX02641 EVLPFCX02641 EVLPF0640 1 EVLPFA0641 EVLPFBX0641 EVLPFCX0641 1 1 /4 EVLPFJ04641 Pendant Mount Pendant Wall Bracket* Ceiling* Stanchion Watt Hub Size (In.) Fluorescent High Power Factor Ballast (Min. P.F. 90%) 52W 64W /4 EVLPFA02520 EVLPFBX02520 EVLPFCX02520 1 EVLPFA0520 EVLPFBX0520 EVLPFCX0520 1 1 /4 EVLPFJ04520 /4 EVLPFA02640 EVLPFBX02640 EVLPFCX02640 1 EVLPFA0640 EVLPFBX0640 EVLPFCX0640 1 1 /4 EVLPFJ04640 *Wall Bracket Mount Complete Catalog Number as follows: 1. Voltages - Add suffix as follows: Standard Voltage Ballasts - 60Hz Optional Ballasts NEC/UL & CEC/CSA (cul) CEC/CSA (cul) Voltage 120 277V 50 60Hz 47V 60 Hz 125V DC 12V DC 24V DC Suffix /UNV /47 /125VDC /012VDC /024VDC *Ceiling Mount Stanchion Mount *Ceiling and bracket mounts have 4 hubs: are plugged. 1084 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 201 Eaton s Crouse-Hinds Business

EVLPF Series Ordering By Components EVLP Luminaires are available in components. A complete light fixture consists of: I. Mounting Module II. Fixture Body III. Guard, Dome Reflector, Angle Reflector, or Exit Sign Mounting Modules: Type Conduit /4" EVMP2 Pendant 1 EVMP /4" EV22 Ceiling & Wall Box 1 EV Wall Bracket Arm Use EV22 or EV box with EV87 EV87 Stanchion 1 1 /4" EVMJ4 Guards Fluorescent Reflectors Dome Angle EV512 RD79 RA79 Pendant Ceiling Stanchion Ceiling Wall Bracket EVMP2 EVMP EV22 EV EVMJ4 EV22 EV EV87 & EV22 or EV Fixture Body EVLPF0520/UNV EVLPF0521/UNV EVLPF0640/UNV EVLPF0641/UNV Guards Dome Reflector Angle Reflector EV512 RD79 RA79 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 201 Eaton s Crouse-Hinds Business 1085

EVLPF Series Low Profile Hazard Gard Luminaires Dimensions and Weights Temperature Performance Data: Fluorescent Fixtures Maximum Ambient Class I, Group B (w/gb suffix) Groups C, D Class I, Zone I 40 C Class II, Groups E, F, G Class III Simultaneous Presence 40 C Supply Wire C Minimum Operating Temperature Fluorescent 52W & 64W T6 T6 75 C 18 C Dimensions In Inches: A B C D E F Fluorescent 15.69 14.69 18.25 18.46 22.4 21.0 Weights: Item Fluorescent (EVLPF) 1.5 Add Mounting Modules: Pendant 1 Ceiling 2 Bracket 4.5 Stanchion 2.5 Add For Reflectors & Exit Sign: RA79 1 RD79 1 DMVF EXD 5 Deduct.5 lb for Wire Guard Lbs. 1086 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 201 Eaton s Crouse-Hinds Business

EVLPF Series Low Profile Hazard Gard Luminaires Photometric Data Luminaire with Globe and Guard EVLPFA0641 Two 2 W www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 201 Eaton s Crouse-Hinds Business 1087

EVLPF Series Low Profile Hazard Gard Luminaires Photometric Data Luminaire with Globe and Dome (Less Guard) EVLPFA0640RD Lamp: Two 2 W Luminaire with Globe and 0 Angle Reflector (Less Guard) EVLPFA0640RA Lamp: Two 2 W 1088 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 201 Eaton s Crouse-Hinds Business