Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features.

Similar documents
ESD500. ESD500 Combustible / Toxic Gas Detector

ESD3000 ESD200 Combustible / Toxic Gas Detector

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

APPLICATION DATA SHEET

ULTIMA XIR ULTIMA X 3 ULTIMA XE. ULTIMA X Series. [ State-of-the-Art Gas Monitoring]

Carbon Monoxide (CO) Gas Detectors with (0)2-10 Vdc or (0)4-20 ma Output

Two-Channel Gas Controller

SP-220. Features. Combustible handheld gas leakage detector

PolyGard Single Point Controller SPC-X3-34XX for Combustible Gases

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

Low mg/m

MERIDIAN UNIVERSAL GAS DETECTOR

Toxic Gas Detection. Model F12. Toxic Gas Detection

TECHNICAL NOTE. Response Factors for Flame Ionization Detector Operation FLAME IONIZATION DETECTOR OPERATION BASICS

ESD3000IR ESD3000IR. Infrared Gas Detector

Meridian. Universal Gas Detector. Description. Features. Minimal drift High specificity Digital ID Broader toxic gas detection

SIL 2. Ultima X Series Gas Monitors CERTIFIED

SBS-H2 Hydrogen Gas Detector Kit

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Frequently Asked Questions

CH 4 C 2 H 2 C 3 H 8 CO 2 H 2 H 2 S HFC NH 3 NO 2 O 2 O 3 SO 2

Dräger Polytron SE Ex Fixed Gas Detector

Gas Central with built-in Gas Detector for Nitrogen Dioxide (NO 2

Murco Core Product Guide Gas Leak Detection Solutions for all your building needs

Explosion-proof Duct Heaters

Model D12-IR. Digital Gas Transmitter...

Product Selection Guide Fixed Gas Detection Systems for Personnel & Equipment Safety

TM-802 Formaldehyde Meter User s Manual

Multifunction IAQ Monitor

IAQ_100 C Package

FACT SHEET Program: Lab Fire Safety

AT-G-SENSE Gas Sensing System

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

Carbon Monoxide CO Transmitter ADT-X3-1110

The product can be worked together with our wireless controller to control a ventilator, air cleaning device, or

4P-90 CiTipeL Combustible Gas Sensor Part Number: PM

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

Installation and Wiring 1.

Gas Detection. - Disposable - Serviceable. Single Gas Detectors

4P75 CiTipeL Combustible Gas Sensor Part Number: PM

IGD.CO.UK

MGS-350 Gas Detector Installation and Operation Manual Instruction Revision 1 February 2013 Product Leadership Training Service

Electron Microscopy Sciences

PCD110X - Premium Choice with DC Motor (Ceiling Mounted Ventilation Fans)

III. 99 Washington Street Melrose, MA Phone Toll Free Visit us at OPERATING INSTRUCTIONS

Carbon Monoxide (CO) Gas Detector March 15 GCO 300

Type SP87300 SAFE-T SHP9 Explosion Proof Stirring Hot Plate

User Manual. PolyGard AT-3300 V3. Transmitter for Combustible Gases. Serial No. ET April 2009

PRODUCT CATALOG 2016 PT. Victoria Globalindo Teknik PT. Victoria Agfasindo

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro

O3TH. Ozone Detector c/w Indicator for Temperature/Humidity. Automatikprodukter. Features. Technical Data. Description. Ordering Codes. Dec.

Hazardous area descriptions

EXAMPLES OF HOW TO ORDER

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white

NGD8800 USER S MANUAL

Combustible Gas Detection and Control System

EXAMPLES OF HOW TO ORDER

Warranty Registration

AirSentry FTIR Multi-gas Open Path FTIR Analyzer

Model D12. Digital Gas Transmitter

Inc Series Digital Gas Detector/Controller. Operation Manual

GAS DETECTION SYSTEMS

3M Oldham OLCT 100. Description. Fixed Gas Detector

The MiCS-4514 is a compact MOS sensor with two fully independent sensing elements on one package.

Air-Quality Detection Module. User s Manual

and storage tanks. CO and NOx detection from diesel engine emissions Hospitality Hotels and restaurants LPG detection in commercial kitchens

Air-Quality Detection Module. User s Manual

OLC(T) 100 FIXED GAS DETECTOR

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

Model VFM200. User Manual. Formaldehyde (HCHO or CH 2 0) and Total Volatile Organic Compounds (TVOC) Tester

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

VSD AND SS DRIVING ATEX MOTORS February 2014

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

ULTIMA XIR ULTIMA X 3 ULTIMA XE. ULTIMA X Series. [ State-of-the-Art Gas Monitoring]

A GUIDE TO EUROPEAN (EEC) CERTIFICATION FOR ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

GAS DETECTION SYSTEMS

Version Inc Series Digital Gas Detector/Controller. Operation Manual

Fire Alarm System Accessories

MICROpeL 75 Combustible Gas Sensor Part Number: PM

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

Nitrogen Dioxide Stand-Alone Detector - Analog, ModBus

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

Dräger PEX 3000 Flammable Gas Detection

compact detector Detection of more than 200 flammable and toxic gases iso 9001:2008

MODEL: Q8 SERIES NON-INTRUSIVE CALIBRATION GAS TRANSMITTER/SENSOR

Manufacturers of Explosion Proof, Corrosion Resistant and Severe Duty HVAC/R Systems, and Pressurization Equipment.

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Shepherd FTIR. Laboratory Quality Results. Continuous, real time portable monitoring of 385 individual species of gas: 100+ HAPs. ...

The MiCS-5524 is a compact MOS sensor.

LFL Monitoring. MEGTEC Systems

Combustible and Toxic Gas Detection Solutions. Performance and Safety Beyond Compliance

GAS PLUS ALARM SYSTEM

SAFETY APPROVED FLASHLIGHTS: UNDERSTANDING THE REQUIREMENTS INTRODUCTION & OVERVIEW

portable gas analyser

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

User Manual. PolyGard Gas Controller MGC3. Two-Channel Analog Gas Controller Serial Number _E _0907. September 2007

GAS DETECTION MANUFACTURED BY. Aerionics, Inc. Sioux Falls, SD Phone:

Explosion protection Marijan Gorše, dipl. ing.

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

Transcription:

Features To measure and take control of indoor air quality Three noses in same unit Air Quality (VOC), Humidity (rh) and Temperature (T) Selectable outputs 0-10 Vdc, 4-20 ma or 0-5 Vdc via jumpers on pcb for all three measurements. Modbus RS485 Network connection, Modbus RTU at 19.2k and 9600 baud VOC = Volatile Organic Compounds sensor also named as a mixed gas sensor LCD Display show actual value for Air Quality (VOC), Humidity (rh) and Temperature (T) Air Quality (VOC) LCD display reading = 0 to 1000 ppm. 0 to 99 ppm = Fine 110 ppm = Fair 400 ppm = Poor 600 ppm = Bad Humidity LCD display reading = 0 to 100% rh Temperature LCD display reading = 0 to 100 C Detectable gases Applications Offices Hotels Meeting rooms Convention centres Schools Airports Apartments Stores, Restaurants etc. Cigarette smoke Automobile exhaust Breath air Carbon dioxide (CO 2 ) Carbon monoxide (CO) Solvent fumes Alcohol fumes Acetone Acrylonitrile Ammonia Benzene Chlorine Dimethyl amine Ethane Ethylene Ethylene oxide Formaldehyde Hydrogen Hydrogen sulfide Isobutane Methane Methanol Methyl chloride Methylene chloride Methy ether Methyl acetate Methyl ethyl ketone n-hexane 2 n-petane Propane R-11 R-12 R-502 R-123 Sulfur dioxide Vinyl chloride Ordering Type no. Description Intelligent combined sensor for Air Quality (VOC), Humidity (rh) & Temperature (T) selectable outputs 0-10 Vdc, 4-20 ma or 0-5 Vdc with Modbus and LCD display. Same as but without set point buttons (for schools, hotels etc)

Air Quality (VOC) reading The reading 0-1000 ppm are corresponding to the output for 0-10 Vdc. >This is adjustable, you can set the full scale range of all parameters by writing to the modbus registers. Operational functions Registers for Reading Temperature, Humidity and Air Quality There are 4 registers to read temperature, humidity and air quality.

Terminal block connections 1 24 Vac live 2 Measurement neutral 3 Temperature output 0-10 Vdc, 4-20 ma or 0-5 Vdc 4 Humidity output 0-10 Vdc, 4-20 ma or 0-5 Vdc 5 Air Quality output 0-10 Vdc, 4-20 ma or 0-5 Vdc 6 Network Communication 7 Network Communication 8 Network Communication Technical data Supply voltage 12-24 Vac/dc +/-20% Power consumption Operation temperature Ambient humidity range 55mA at 24 Vdc -30 to +70 C 0-100% rh Material, enclosure Flame proof plastic Enclosure rating IP 31 Colour Weight White 200 g (approx.) Accuracy The Air Quality (VOC) sensor will react differently according to the type of gas, the humidity accuracy is +/- 3% rh and temperature accuracy is +/- 0.2 C.

Dimensions

The analogue outputs 0-10 Vdc, 4-20 ma and 0-5 Vdc are corresponding to: Air Quality 0-1000 ppm, Humidity 0 to 100 % rh and Temperature 0 to 100 C. Air Quality (VOC) Humidity Temperature Temperature C

Modbus Registers Air Quality Sensor uses MODBUS protocol to communicate with others. Following is a table of MODBUS Registers.