Similar documents
Statement of Responsibilities

Parts Manual. Counter Type Electric Convection Steamer. Series: SteamCraft Models 21CET East 179 th Street Cleveland, Ohio 44110

Parts Manual. Gas Floor Type Convection Steamer. Series: SteamCraft Model 24CGA East 179 th Street Cleveland, Ohio 44110

Parts Manual. Counter Type Gas Convection Steamer. Series: SteamCraft Model 21CGA East 179 th Street Cleveland, Ohio 44110

Statement of Responsibilities

Statement of Responsibilities

Statement of Responsibilities

ME SERIES ELECTRICALLY OPERATED BOILERS INSTALLATION - OPERATION - MAINTENANCE MODELS

CAUTION All safety information must be followed as provided in this Technical Sheet and in Service Manual RS

Fast Track Troubleshooting

STEAMPRO. Steam Generator Troubleshooting and Service Guide

INSTALLATION AND OPERATION MANUAL STEAM COIL BASE CONVECTION STEAMER MODEL SCX-16

Fast Track Troubleshooting

Fast Track Troubleshooting

Fast Track Troubleshooting

Fast Track Troubleshooting

Wiring Diagrams DIAGRAM INDEX

Please read this manual completely before attempting to install, operate or service this equipment

TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA

PS-3E AND PS-6E ELECTRIC CONVECTON STEAMERS PARTS AND SERVICE MANUAL

Installation, Operation, and Maintenance Manual RTE14S & RTE14S-2. For the Taco Bell "Rethermalizer" Model Numbers

Fast Track Troubleshooting

Dishwasher Cycle Chart Air Vent Dry System

Your safety and the safety of others are very important.

Fast Track Troubleshooting

Service Manual. Models 17700/17701/17703 Recovery/Recycling/Recharging Unit For R-12 Only

Heat Pump Defrost Board Replacement Kit

southbend A MIDDLEBY COMPANY INSTALLATION AND OPERATION MANUAL CG214 (E) CG314 (E) CG414 (E) CG220 (E) CG320 (E) CG325 (E) GAS BOILERS MODELS:

The information presented in this manual applies to the 27" negative pressure dryer, both electric and gas models.

Fast Track Troubleshooting

Part Number DOMESTIC. HyPerSteam Atmospheric Convection Steamer BETA 1.0

TSC & TSC-M Proofer/Oven

COS-101 NON SELF FLUSHING COMBI REPLACEMENT PARTS LIST

Fast Track Troubleshooting

CROWN SERVICE MANUAL ELECTRIC COUNTERTOP STEAMERS MODELS: PX-3 PX-5

GB5MV-10-LD GB6MP-10-LD-U GB8MP-10-LD-U

Super Runner Series Electric Fryers

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor Undercounter AquaTemp HUMIDITY OVENS and CONVECTION OVENS 2000 WATTS

SINGLE-PACKAGE ROOFTOP HEAT PUMP UNITS INDEX. VOLTAGE (3 Ph, 60 Hz) ACCESSORIES

T9MPV SmartComfort VS90 Product Specifications

USER MANUAL WARNING! CONTENTS MODEL SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS

Fast Track Troubleshooting

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS

Fast Track Troubleshooting

Express Price List Popular Models & Accessories. QS QUICKSHIP ITEMS (48 hour) EX EXPRESS ITEMS (10 work day lead time)

ALTAIR II CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

Effective october 14, 2014

Wiring Diagrams. 38ARZ ARS ARD Air-Cooled Condensing Units 50/60 Hz

IMPORTANT INFORMATION, READ BEFORE USE. PLEASE SAVE THESE INSTRUCTIONS.

Fast Track Troubleshooting

Replacement Parts List For Models COS-20G

Fast Track Troubleshooting

ACCESSORY KIT INSTALLATION INSTRUCTION 2PH0852* SERIES ELECTRIC HEAT ACCESSORIES SPECIFICATIONS

Cleveland Range Inc. COMBINATION COOK TANK, CHILLER & SOUS VIDE PRODUCTION UNIT. Cleveland General Specifications. Cleveland Standard Features

UPM I. Unit Protection Module. Installation and Operation Manual (2015/06)

Dishwasher Cycle Chart Air diffusion condensing Dry System

Installation Manual CARBONATOR With Plain-Water Booster

Effective october 14, 2014

MODELS SSB-3E/5E/10EF, (2)SSB-3E/5E/10EF, SSB-3G/5G/10GF, (2)SSB-3G/5G/10GF

Fast Track Troubleshooting

Outdoor Reset IQ Option Card, p/n

CONTACTING CONDUCTIVITY BOILER SENSORS Instruction Manual

KLE-235D DOUBLE RACK IN-LINE CONFIGURATION KLE-175GTM SINGLE RACK THREE-DOOR CONFIGURATION KLE SERIES ULTRA WASH DISHMACHINE INSTRUCTION MANUAL

Outdoor Reset IQ Option Card, p/n

INSTALLATION and OPERATION MANUAL DIRECT STEAM KETTLES MOUNTED ON ELECTRIC BOILER BASE CABINET MODELS: EMT-6 EMT-10 EMT-12 EMT-6-6 EMT-10-6 EMT-10-10

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

3500 SERIES CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL

OPERATION INSTRUCTIONS DEMAND DEFROST CONTROL BOARD MODEL FOR USE WITH MODELS: AFFINITY, ECHELON, ACCLIMATE HEAT PUMP SERIES

Operation Manual NEMA 4X Controls

Replacement Parts List For Models COS-101 COS-101S

INSTALLATION AND MAINTENANCE INSTRUCTIONS EF Electric Furnace

MODELS R & RH 10 THRU 20 RB SERIES ELECTRIC STEAM BOILERS

Installation Manual. Energy Star SteamChef Models 22CET3.1 and 22CET6.1 PATENT PENDING East 179 th Street Cleveland, Ohio 44110

Control Panel For Water Wash Hoods AM2

USERS INFORMATION MANUAL

L A signature series TA T N E RE O, A L L A T S IN

KARMEL KING Instruction Manual Models: 2620 & 2621 (240 Volt) 2630 & 2631 (208 Volt) Part No Revised: February 2009

Fast Track Troubleshooting

MODEL CMA-180UC INSTALLATION & OPERATION Rev 1.17A

Electrical Problems. Fuse(s) blow or circuit breaker trips. Does the unit use circuit breakers or fuses? Replace with correct fuse(s)

Operator s Manual. Energy Star SteamChef Models 22CET3.1 and 22CET6.1 PATENT PENDING

HOSHIZAKI AMERICA, INC. SERVICE BULLETIN

USER MANUAL 2000NC MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. Builder Series 5-2 Day Programmable Single Stage Heat/Cool Digital Thermostat

SUPPLEMENT PARTS LISTING WIRING DIAGRAMS FOR MT-25,40 & 60EO - KETTLES

CHILLER. Operator s & Installation Manual

Cleveland. When You Need a Lot and Need It Fast

U155 Series Ice and Beverage Dispensers

Fast Track Troubleshooting

WARNING Important Safety Information

The Information Contained in this Document is Proprietary and should only be used for Service or Training of Authorized Blodgett Servicers who will

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

MODELS: TJ45 TJ90 Operator s Manual

Machine Serial No. Technical Manual. International Door Dishwasher. February, 1998 Manual P/N Rev.A

INSTALLATION INSTRUCTION

ECOJET EJ-10E & EJ-7E ELECTRIC CONVECTION STEAMER W/TWIN GENERATORS PARTS AND SERVICE MANUAL

IW-25-2 Dehumidifier Installation & Operations. Manual

HD3D Forced-Air Heater

TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA

Transcription:

Statement of Responsibilities This document is for use by experienced and trained Qualified Cleveland Range, LLC Authorized Service Representatives who are familiar with both the safety procedures, and equipment they service. Cleveland Range, LLC assumes no liability for any death, injury, equipment damage, or property damage resulting from use of, improper use of, or failure to use the information contained in this document. Cleveland Range, LLC has made every effort to provide accurate information in this document, but cannot guarantee that this document does not contain unintentional errors and omissions. The information in this document may be subject to technical and technological changes, revisions, or updates. Cleveland Range, LLC assumes no liability or responsibility regarding errata, changes, revisions, or updates. Qualified Cleveland Range, LLC Authorized Service Representatives are obligated to follow industry standard safety procedures, including, but not limited to, OSHA regulations, and disconnect / lock out / tag out procedures for all utilities including steam, and disconnect / lock out / tag out procedures for gas, electric, and steam powered equipment and / or appliances All utilities (gas, electric, water and steam) should be turned OFF to the equipment and locked out of operation according to OSHA approved practices during any servicing of Cleveland Range equipment Qualified Cleveland Range, LLC Authorized Service Representatives are obligated to maintain up-to-date knowledge, skills, materials and equipment.

Cleveland Range, LLC 1333 East 179th St., Cleveland, Ohio, U.S.A. 44110 P h : 1-216-481-4900 F x : 1-216-481-3782 Visit our Web Site at www.clevelandrange.com

CLEVELAND RANGE 24CEA10 SEQUENCE OF OPERATIONS Mechanical Timer 1. Supply power is sent to the primary of the main transformer. 115 VAC is sent from the secondary of the main transformer to the on/off rocker, 2. To turn the unit on, depress the red on/off rocker switch. 115 VAC is sent to the red indicator light. 115 VAC is sent to both coils of the normally open drain valves closing them. 115 VAC is sent to the H and N terminals of both water level boards. 3. With the water level board energized and no water in the generators After a 5 second delay, 115 VAC is sent from the FILL terminals to the fill solenoids. The fill solenoids open and the generators fill through the drain valves until the high probe is grounded (see step 4). The water fills to the low probe in each probe assembly shorting it to ground 115 VAC is sent from the HEAT terminals of the water level board to the timed manual switches. 115 VAC is sent to the heat standby timer which will energize the R2 relay coil 3 seconds every 4 minutes The normally open contacts of the R2 relay close bypassing the timed/manual switch to maintain heat while unit is idle 4. For each compartment, when the timed/manual switch is in the manual position or timed position with time on the timer 115 VAC is sent from the timer to the coil of the R5 relay for the top compartment The R5 relay energizes R5B contacts close sending 115 VAC to the motor timer R5A contacts close sending 115 VAC through the optional door switch to the normally closed contacts of the high limits 115 VAC is then sent through the high limits to the coil of condensate solenoid and the coil of the contactor. 115 VAC is sent to the clean light timer. When the clean light timer times down 115 VAC is sent to the clean light switch. When the clean light switch is depressed the timer is reset. When the contactor is energized supply voltage is sent to both of the elements. 115 VAC is sent from the timer to the coil of the R6 relay for the bottom compartment The R6 relay energizes R6B contacts close sending 115 VAC to the motor timer R6A contacts close sending 115 VAC through the optional door switch to the normally closed contacts of the high limits 115 VAC is then sent through the high limits to the coil of condensate solenoid and the coil of the contactor.

115 VAC is sent to the clean light timer. When the clean light timer times down 115 VAC is sent to the clean light switch. When the clean light switch is depressed the timer is reset. When the contactor is energized supply voltage is sent to both of the elements. When the mechanical timer times out 115 VAC is sent to the 3-second timer and then to the buzzer for 3 seconds. 5. When the water level reaches the high probe then 115 VAC is removed from the FILL terminal and the fill solenoid is turned off. 6. After the water level drops below the high probe for 5 seconds 115 VAC is sent to the FILL terminal again. 7. The red 115 VAC switch is depressed and the unit is turned off. 115 VAC is removed from the timer and heat circuits. 115 VAC is removed from the normally open drain valves allowing the steamer to drain. 115 VAC is sent to the 3-minute timer and the R1 relay coil is energized. The normally open contacts of the R1 relay will close The fill solenoids are then energized for 3 minutes flushing the drains.

DRYING ELEMENT STEAMCRAFT-10 ELECTRIC MECHANICAL TIMER DRYING ELEMENT HEATING ELEMENTS CONTACTORS HEATING ELEMENTS NOT USED ON " LOW " WATTAGE MODEL NOT USED ON " LOW " WATTAGE MODEL CUSTOMER CONNECTION 3Ø L1 L2 L3 H1 H4 PRIMARY TB X1 TRANSFORMER X2 SECONDARY BLK 120V WHT 3 4 2 7 8 1 6 5 DESCALER TIMERS 3 2 4 7 8 1 6 5 L NO A L DESCALE INDICATOR & RESET SWITCH NO 3 2 1 3 MIN TIMER POWER SWITCH POWER ON R R1 COIL R1 R1 WATER FILL VALVES HEAT WATER BOARD FILL H N XL HI C TO PROBES MANUAL TIMED MANUAL R5B C NO C NO MOTOR C R5A NC NO TIMED R5 DOOR SWITCH (SCS OPT) 3 SEC TIMER 3 2 BUZZER 1 R3 (TDS OPTION) COND. VALVE UPPER MOTORIZED TIMER R3 NC C BLOWDOWN TIMER OPTION MANUAL 1 3 TIMED MOTOR 2 C NO NC R6B C NO R6A MANUAL C NO R2 TIMED R6 DOOR SWITCH (SCS OPT) HI LIMIT SWITCHES UPPER DRAIN VALVE HEAT WATER BOARD FILL H N XL HI C 1 HEATER CONT. 3 SEC TIMER 3 2 BUZZER TO PROBES R4 (TDS OPTION) COND. VALVE LOWER MOTORIZED TIMER R4 NC 1 C 2 BLOWDOWN TIMER 3 OPTION 1 R2 HEATER CONT. HI LIMIT SWITCHES LOWER DRAIN VALVE 2 R2 COIL 3 HEAT STANDBY TIMER L105972 K

BLK PNK 9 W/BLU 22 PNK 9 W/BLU 22 7 GRA BLK C BLK 6 LT BLU NO BLK BLK 20 R5 WHT/BLK W/BLU 7 W/BLU NC WHT/GRA WHT WHT/ ORN ORN/BLK LT BLU LT BLU WHT/BLK WHT/BLK 3 2 1 3 C 2 NC 20 LT BLU NO BLK BLK R6 ORN ORN/BLK LT BLU LT BLU WHT 2 2 1 WHT/BLK BLK LT BLU LT BLU BRN WHT BRN BLU BRN BLK REMOVED W / OPTIONAL DOOR SWITCH ( SCS ) YEL WHT BRN BRN BLU BLU 24 REMOVED W / OPTIONAL DOOR SWITCH ( SCS ) 24 YEL GRA BRN 4 YEL WHT GRA 25 26 WHT/ WHT/GRA BLK BRN WHT/BRN 15 BLU CUSTOMER CONNECTION 3 FU ( TOP ) ( BOT ) YEL YEL WHT/YEL BLACK BLACK WHITE WHITE BLACK BLACK WHITE WHITE ALTERNATE TRANSFORMER CONFIGURATION FU ORN H4 H2 H3 H1 JUMPER SET FOR 480 VOLTS H4 H2 H3 H1 20 R1 BLU 15 N WHT DRYING ELEMENT HEATER ELEMENT HEATER ELEMENT 1 X1 JUMPER SET FOR 208/240 V 1 10 BRN X2 X1 X2 PNK 3 2 1 STEAMCRAFT 10 - ELECTRIC MECHANICAL TIMER GRA WHT/YEL YEL WHT/GRA BLK BLK WHT WHT/GRA 5 YEL BRN WHT/BRN WHT WHT/YEL 4 WHT/ BLU BLK WHT/YEL BLK YEL BLU BLK WHT WHT/GRA BRN BLK BLK YEL BLK ORN BLK BLK WHT BLACK BLACK WHITE WHITE HEAT FILL H N BLACK BLACK WHITE WHITE 17 11 WHT 23 HEAT FILLH N 21 XL HI C YEL 3 2 1 WHT DRYING ELEMENT HEATER ELEMENT HEATER ELEMENT WHT/ WHT/YEL WHT/YEL YEL 21 YEL GRN YEL WHT/BRN ORN XL HI C GRN BLK BLK BLU WHT/ 8 BRN R2 17 20 YEL BLK 18 12 ORN 18 BLU BRN 3 2 4 1 78 6 5 TAN TAN BRN BLU BRN WHT/BRN WHT/ WHT/ORN WHT/BRN WHT/YEL WHT/YEL YEL YEL WHT BLK 12 BRN WHT 3 2 4 7 8 BLK ( TOP ) FILL ( BOT ) FILL ( TOP ) COND ( BOT ) COND ( TOP ) 16 ( BOT ) 16 1 6 5 14 19 TAN TAN NOTE : THIS ELEMENT NOT INSTALLED FOR " LOW " WATTAGE UNIT BRN YEL R3 20 3 WHT 13 2 1 R4 YEL 13 3 2 BRN 4 1 7 8 6 5 INTERMITTENT BLOWDOWN OPTION 3 2 1 3 2 4 1 7 8 6 5 12 PARTS LIST WHT 16 1 20535 - TRANSFORMER - POWER 2 20477-3 SEC TIMER 3 02193 - TERMINAL BLOCK 4 101541 - TERMINAL SEGMENT 5 106175 - TERMINAL BLOCK 4 POLE 6 19993 - POWER SWITCH 7 104224 - TIMED / MANUAL SWITCH 8 19994 - DESCALE IND RESET SW 9 110198 - MOTORIZED TIMER 10 20478-3 MIN TIMER 11 109239 - HEAT STANDBY TIMER 12 106911 - DESCALE TIMER 13 106541 - INTMT BLOWDOWN TIMER 14 222231 - FILL VALVE 15 03459 - CONTACTOR ASSY 16 22221 - DRAIN VALVE 17 103731 - HI LIMIT SWITCH 18 107239 - PROBE 19 22218 - WATER SOLENOIDS 20 105966 - RELAY 21 107241 - WATER BOARD 22 41350 - BUZZER 23 44168 - TERMINAL BLOCK 2 POLE 24 108880 - DOOR SW ( SCS ) MAG 25 109380 - FUSE 3.5A 600V 26 109374 - FUSE BLOCK 5 16 WHT WHT P105972 K WHT

PROBLEM: 21CET8 21CET16 21CEA10 Steamer won't steam. Steamer won't steam Is the red light on? Is there supply voltage to the primary of the transformer? Supply power to the steamer. See STEAMER WON'T FILL Is there water in the sight glass? Is there 115 VAC at the secondary of the transformer? Replace the transformer. Replace the wires to the water board. Is there 120 VAC between terminals H and N on the water board? Replace the on/off rocker switch Replace the water board With a jumper between XL and C on the water board, is there 120 VAC between N and Heat? Is there 120 VAC between terminals N and Heat on the water board? Replace the wire from the water board to the long probe. Is there debris on the Long probe? Is there 115 VAC to the common terminal of the timed/manual switch? Replace the wires to the switch. Clean or replace the probe assy. Does the unit steam in Manual mode? Replace the timer. Does the steamer have the optional door switch? Does steamer steam with door switch bypassed? Is there 115 VAC to the high limit? Is there 115 VAC leaving the high limit? Is there 115 VAC to the coil of the contactor? Replace the wires to the high limit. Replace the high limit. Replace the wires to the contactor coil. Adjust or replace the door switch. Is there an amp draw at the element? Replace the element. Wait longer for the steam. Heat from the element will heat the water to steam.

PROBLEM: 21CET8 21CET16 24CEA10 Steamer wont fill Steamer wont fill. Is there supply voltage to the steamer? Supply power to the steamer. Is there water to the steamer? Supply cold water to the steamer. Is there 120 VAC between the H and N on the water board? Replace the on/off rocker switch. Is there 120 VAC between Fill and N on the water board? Remove the wire from the HI terminal on the water board. Is there 120 VAC between Fill and N? Replace the water board Replace wiring to the fill solenoid. Is there 120 VAC across the coil of the fill solenoid? Is there debris on the HI probe in the probe assy? Replace the wire to the Hi probe. Replace the fill solenoid Is water leaving the fill solenoid? Clean the probes or replace the probe assy. Replace wiring to drain valve. Replace the wiring to the intermittent blowdown timer. Does the steamer have the optional intermittent blowdown timer? Is there 120 VAC between terminals 2&3 on the timer? Is there 120 VAC across the coil of the drain valve? Is water draining from the generator? If water is leaving the fill solenoid and not draining from the generator where is it going? check for leaks.. Replace the intermittent blowdown timer. Replace the drain valve.

PROBLEM: 21CET8, 21CET16, 24CEA10 Electronic timer displays "PAUS" and won't count down Timer displays "paus" and won't count down Is steam heating the cooking cabinet above 192 degrees (the set temp of the thermo-switch)? See Steamer won't steam Replace the thermo-switch Does the timer count down when the thermo-switch is bypassed? Replace the electronic timer PROBLEM: 21CET8, 21CET16, 24CEA10 Steam leaks around the door. Steam leaks around the door Is COLD water supplied to both water lines to the steamer? Supply cold water(35-60 psi) to the steamer. Is the door gasket physically damaged? Is the door out of alignment? Is the drain obstructed? Is there 120 VAC across the coil of the condensate solenoid? Replace the wiring to the condensate solenoid. Turn over the gasket or replace it. Replace the door bearings and pins. Remove the obstruction Is the solenoid opening? Replace the condensate solenoid. Replace the condensate spray nozzle

PROBLEM: 21CET8 21CET16 24CEA10 Steamer overfills. (Water sprays into cooking cabinet) Steamer overfills (Water sprays into the cooking cabinet) Start There is an obstruction in the drain. Remove the obstruction. Does the rise in the water level in the sight glass stop when the cooking cabinet door is opened? Does the water rise in the sight glass when steam is generated and 0 VAC to the fill solenoid? Does the water level in the sight glass stop at the HI (short) probe on the initial fill? There is an obstruction in the generator causing it to pressurize. Delime the steam generator thoroughly. Replace the fill solenoid There is an obstruction in the plumbing to and from the sight glass. Remove the debris (delime thoroughly). Does water spray in the cabinet before the water reaches the HI (short) probe? Replace the three minute timer. Remove the wire from the Fill terminal on the water board. Is there 120 VAC across the coil of the fill solenoid? Is there 120 VAC across the coil of ;the fill solenoid when the HI (short) probe is submerged? Replace the water level board. With HI and C terminals on the water board jumped, Is there 120 VAC between terminals N and Fill? Replace the fill solenoid Clean or replace the probe assembly. Is there debris on the HI (short) probe? Replace the wire to the probe assembly

Steamer won't stop steaming Is the timed/manual switch in the timed position with no time on the timer? Steamer will steam constantly in the manual position. Put the timed/manual switch in the timed position with no time on the timer. PROBLEM: 21CET8 21CET16 24CEA10 Steamer won't stop steaming with door open Does the steamer have the optional door switch? Adjust or replace the door switch. Does steamer continue to steam with both wires removed from terminal 1 on the heat standby timer? Replace the heat standby timer. Is there 120 VAC to the coil of the contacter? Replace the timer. Is there an amp draw at the element? Replace the contactor When supply voltage is removed from the element steam is still made for approximately 10 seconds. This is normal. Problem: 21CET8, 24CEA10 Steamer won't preheat Steamer won't preheat Is the timed/manual switch in the timed postion with time on it or in the manual postion? This steamer is not equiped with a preheat thermostat. The timed manual switch must be in manual or time must be on the timer. See Problem: steamer won't steam.

Descaling Procedure-SteamCraft Ultra and Gemini Series How Much DISSOLVE to Use Model Dissolve Ultra 3 1/2 Gallon Ultra 5 1 Gallon Ultra 10 (Elec.) 1 Gallon (ea.) Ultra 10 (Gas) 1½ Gallon Gemini 6 & 10 1 Gallon (ea.) 6. Let the descaler soak in generator for approximately one hour: 7. After one hour, turn the unit power Off: This will drain and rinse the generator for about 3 minutes. 1. Turn the unit OFF and open the doors: This will drain and rinse the generator for about 3 minutes. 2. Turn the unit power back On: The generator will begin to refill with water. 3. Select Timed with the Timed/Manual switch: DO NOT start the timer, since you do not want to heat the water during descaling. Leave the doors open. 4. Remove descaling port cap and add with the specified amount of DISSLOVE: (See chart above) Do this while the unit is refilling. The generators can take-up to 8 minutes to refill. 5. After refill has stopped, add extra tap water into the descaling port until liquid is seen entering the cooking cabinet. te: Ultra 10 gas will have liquid coming out of the drain, Adding extra water when descaling will raise the descaling solution higher than the normal fill level, allowing the DISSOLVE to work on sensors and surfaces above the water line te: Some SteamCraft Ultra models (the electric powered Ultra 10 and Gemini 6 and 10, for example) have two generators and two descaling ports. Both units should be descaled at the same time, using this procedure 8. After the 3-minute drain cycle completes, turn the unit back ON. After the filling has stopped, add water until liquid enters the cooking compartment (or drain for the ultra 10 gas), and then turn the unit OFF. This will drain and flush any residue from the water level control assembly. Replace descaling cap. 9. After the 3 minute drain cycle completes, Turn the unit ON and set the Timer for 20 minutes: Make sure the Time/Manual switch is in the timed setting and the doors are closed. 10. When the timer times out (after 20 minutes) turn the power Off: This will drain and rinse the generator for about 3 minutes. This ends the descaling procedure. You can now turn the unit back on and resume normal startup and cooking operations.