Item No. (Standard/Opposite Hand) /

Similar documents
Item No. (Standard/Opposite Hand) /

Item No. (Standard / Opposite Hand) /

Item No. (Standard / Opposite Hand) /

Unit Controller (UC8) Quick Reference Operation and Fault Diagnosis

S Y D. HWP 35, 47, 58 (c/w EC Motor & UC7 Controller) Ducted Water Cooled R410A Packaged Air Conditioner. Installation & Maintenance

DUCTED WATER COOLED PACKAGED AIR CONDITIONERS HWP models (c/w UC8) Installation & Maintenance

Water Cooled Units HWP 370, 445. Cooling Capacity 36.6kW kW. Heating Capacity 34.9kW kW

S D HWP 77, 96. Ducted Water Cooled R410A Packaged Air Conditioner. Installation & Maintenance. Fig. 1 Nomenclature. Fig.

TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA

OPTIONAL SPRING MTG HANGING CENTRES WATER CONN'S: TWO BSP MALE. 19 mm (3/4") ELECTRICAL CONDUIT HOLES ACCESS PANEL OUT (WATER) IN 485 MOUNTING

OPA RKTG-P (ECO) c/w UC8 Air Cooled Packaged Units - Reverse Cycle - R410A Installation & Maintenance

REVERSE CYCLE DUCTED SPLIT SYSTEMS (ISDL/OSA c/w UC8/IUC) Installation & Maintenance

Water Cooled Air Conditioners Applications Manual

UNIT CONTROLLER 8 (UC8) Troubleshooting guide

Ducted Split System Air Conditioners Technical Data

MEPS COMPLIANT. Product Review OPA-RK Series. Ducted Packaged Roof Top Air Conditioners kw 137 kw. Extra Long Life Epoxy Coated Outdoor Coil

ENGINEERING SPECIFICATIONS

Cooling Capacity 3.5kW kW. Heating Capacity 4.4kW kW. Air Conditioning. Giving you complete control

ENGINEERING SPECIFICATIONS

Ducted Split System Air Conditioners Technical Data

Technical Data ISU Series. Underceiling/Console Split System Air Conditioners kw 15 kw

Technical Data OPA 294, 340, 370. Ducted Three Phase Packaged Air Conditioners kw 34.0 kw 39.1 kw. Twin System Enables Staging

Engineering Data Manual

TECHNICAL, OPERATING & INSTALLATION MANUAL TC 15, 33, 52 AIR COOLED PACKAGED WATER CHILLERS

Technical Data ISD 184KY / OSA 184RKTV. Ducted Split System Air Conditioner kw

Technical Data ISD 87KYX / OSA 87RKSH. Ducted Split System Air Conditioner. 8.5 kw

Multi Inverter Air Conditioning Condensing Units - Summary

Technical Data OPA RKTBG-P. Ducted Three Phase Packaged Air Conditioners. 47 kw 96 kw

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER. Models CONTENTS

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

CAUTION. All safety information must be followed as provided in Service Manual RS ! WARNING

TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA

TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

Carisma Fly Carisma Fly-ECM. Made in. Italy. High Wall Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT

Applied Packaged Terminal Air Conditioner with Catalog Top-Mounted Hydronic Heat

SpaceKeeper Console (SKC)

Self-Contained & Split System Reverse Cycle Air Conditioners Models

Technical Data Ducted Three Phase Split System Air Conditioner

Product Data. Features/Benefits. 07DA, DB 07EA, EB, ED Condensing Units. 06D, 06E Compressors. 3 to 40 Nominal Tons

GUIDE SPECIFICATIONS AQUARIUS ii

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

Cooling Capacity 3.5kW kW. Heating Capacity 4.4kW kW. eco. series. Air Conditioning. Giving you complete control

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

Application and Installation Bulletin for Master-Bilt Refrigeration Superheat Controller Kit Assembly(A ), 120/208/240/1/60, R404A, LT/MT APPS

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

SINGLE-PACKAGE ROOFTOP HEAT PUMP UNITS INDEX. VOLTAGE (3 Ph, 60 Hz) ACCESSORIES

Carisma Fly. Made in. Italy. Wall-mounted Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT.

Air Cooled Scroll Compressor Condensing Unit

Technicians Manual Single Compressor

CME1856W Service Parts

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

UPM I. Unit Protection Module. Installation and Operation Manual (2015/06)

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

Commercial High-Efficiency Condensing Units

OPA RKTG-P (ECO) Air Cooled Packaged Units - Reverse Cycle - R410A Installation & Maintenance

GUIDE SPECIFICATIONS AQUARIUS ii

DANFOSS OPTYMA PLUS INVERTER UNITS

HID312, HID525 and HID540 Service Parts

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

Evolution Electric Heat Modulator CONTROLS INC. EVO/ EHM-S3

Refrigeration / Air Conditioning Systems Circuit Drawings. Student Resource Package No: NR 24

TECHNICAL GUIDE VARIABLE SPEED AIR HANDLERS DESCRIPTION FEATURES Rev. A (0105)

High wall fan coils Climmy FHW/FHW-ECM. Technical Catalogue

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

Conditioning your ambient, maximising your comfort.

Modular Air Cooled Scroll Chillers

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

CME650 SERVICE PARTS

Danfoss Scroll for Refrigeration MLM / MLZ

CME1856W Service Parts

Digital Inverter 4 series 8 & 10HP

CMS1402 SERVICE PARTS

4A6H5042G1000A 208/230/1/ DURATION - SCROLL 3/4 208/230/1/ NO (Use BAYKSKT263) YES YES PROPELLER DIRECT

Self-Contained & Split System Reverse Cycle Air Conditioners SAB Self-Contained Units, CAB Condensers and DEAH Air Handlers

Service Engineers Manual (for software version ) Duo 2 Duo 3 Duo 500 Duo 750

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

LSN DC Inverter Series

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

DUCT type. SPLIT TYPE AIR CONDITIONER (50Hz)

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

E1 Electrical Fundamentals. # 4 - Symbols and Wiring Diagrams

RE-PR3-E-27 3-Phase Panel Mount 27kW

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42

Technical Data VPA 120, 160. Ducted Vertical Packaged Air Conditioner/Heat Pump kw 16.1 kw. Wide Ambient Capabilities

Specifications and Performance S2H

ENGINEERING SPECIFICATIONS

SPLIT SYSTEM AIR CONDITIONER

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

ENGINEERING SPECIFICATIONS

Refrigerant R407C CW-AR. 2.4 to 3.1kW. Water Source Heat Pumps - Vertical Mounting Version Models 07 to to 2.7kW

ECONOPLATE H1-heat only HEAT INTERFACE UNIT. Installation, Commissioning and Servicing Instructions for unvented systems.

Due to a possibility of personal injury or property damage, always contact an authorized technician for service or repair of this refrigerator.

KPSW CONSOLE TERMINAL UNIT

TECHNICAL DATA & SERVICE MANUAL

Air Cooled Scroll Chiller / Heat Pump

Transcription:

SPECIFICATIONS Model HWP 59RKS Item No. (Standard/Opposite Hand) 509-059-001 / 509-059-011 Cooling capacity (net) to AS/NZS 3823 T1 5.7 kw Heating capacity H1 5.4 kw Electrical input - cooling 1.6 kw Electrical input - heating 1.5 kw EER / AEER (cooling) 3.61 / 3.60 Unit Controller UC8 Refrigerant R410A Refrigerant charge 1.05 kg Compressor type rotary connections 1/2" male SP Nominal EWT on cooling 30 C Nominal EWT on heating 21 C Nominal Flow @ EWT LWT = 5k 0.34 l/s Entering system pressure drop @ nominal flow 41 kpa (6 psi) Min. water temp. Heat cycle at nominal flow 10 C Min. water temp. Cool cycle at nominal flow 15 C Min. water temp. Cool cycle with water flow control valve 5 C Max. EWT Heat cycle at nominal flow 30 C Max. EWT Cool cycle at nominal flow 50 C Min. water flow @ nominal EWT 0.09 l/s Max. water pressure excluding hoses 3200 kpa (464 psi) Power supply 1 ph. 23 ac 50Hz Compressor run amps at rating cond. 6.6 A Compressor run capacitor 40 µfd Indoor fan motor size 230 W Indoor fan motor (1ph.) - full load 1.9 A Control circuit breaker (internal) 10 A Running amps (total system) 7.6 A Max. running amps (total system) 11.2 A Net weight 85 kg Accessories: Spring mounts supplied hoses 600mm long, rated 250psi 1/2" female SP, supplied Replacement filter 119-000-086 840x265x13 Condensate lift-pump 507-003-009 Optional: SAT-3 Room temperature controller 201-000-146 TZT-100 Room temperature controller 201-000-350 Refer to temperzone for other options, eg remote sensors Tested in accordance with AS/NZS 3823 15053

DIMENSIONS (mm) PROJECTION HWP 59RKS Standard W Air Flow ELECTRICAL OX X Not to Scale POINT LOADS (kg) W X Y Z 21 26 23 15 Note: Fan motor can be accessed from panel above, below or sides; no more than two panels at once. Z Air Flow Y HWP 59RKS Opposite Hand POINT LOADS (kg) W X Y Z 26 15 21 23 Note: Fan motor can be accessed from panel above, below or sides; no more than two panels at once. NOTE Specifications are subject to change without notice due to the manufacturer's ongoing research and development programme.

ELECTRICAL TL2W1 External Protection & Isolation N N1 N2 T1 T2 T3 T4 ETH3 CC Pump Verification Dry Contacts If Pump Verification Option fitted remove this link T6 Flow 1 Flow 2 E1 T7 Pump 1 Pump 2 Active A 6-A 6- C 6-D D 7-D UC8 DIP switch settings UC8 JUMPER settings DIP switch On/Off 1,13,14 On All Others Off Off Position Jumper J1 J2 REV DESCRIPTION ECN temperzone Ltd 2014 DATE DO NOT SCALE - ASK APPROVED Contactor now single pole. Earth points N3805 21-01-16 D.A.. changed. C Main Earth Symbol updated N3837 19-03-16 D.A.. D FR & SR now fitted as standard N3941 23-05-17 D.A.. Client Wiring CAP1 S R C CM M 1~ SR 1-C A 1-C Condensate Pump FR UC8 Temp Sensors (Refer to table) 1 A1 FLT EXV1 EXV2 AUX HI ME LO C1 IN#1 IN#1 C2 HT CP IN#2 IN#2 DL SL 12 2 A2 Modbus master port for optional T/stat (TZT100/SAT-3) Flow Control Valve E HIGH MED LOW C3 HPT LPT AM Pressure sensors DEI OC IC V1 V2 D1 D2 D3 SC ON CP4W1 CP2W1 0-1 to Regulating Valve If Condensate Float Switch Option fitted remove this link Condensate Float Switch (Normally closed) N L R/V R/V SSR1 SSR1 SSR2 SSR2 5 VF 12 VC TL2W2 L1 T5 ETH2 D 24VAC/12VDC controls Optional 0-1 controls E2R Relay 2 D DP1 Refer to DIP S/W settings Display SW1 SW2 J1 J2 Modbus slave port for MS (monitoring or control option) Relay 1 SW3 C4 Remote On/Off Dry Contact RV C 1-D D 1-D If Remote On/Off Option fitted remove this link CAP2 ORG ORG RN (HIGH) RED (MED-HI) LU M 1 GRY (MED-LOW) IFM1 WHT (LOW) Sensors (S) / Transducers (T) Name Type Colour DL Discharge Temp S RED SL Suction Temp S WHITE IC Indoor Coil S YELLOW HPT High Pressure T CAP CAPACITOR CC CONTROL CIRCUIT REAKER CM PRESSOR MOTOR PRESSOR CONTACTOR CP2W CONNECTOR PLUG 2 WAY CP4W CONNECTOR PLUG 4 WAY E2R EXV2 RELAY OARD FR FAULT RELAY OARD ETH EARTH IFM INDOOR FAN MOTOR RV REVERSING VALVE SR STATUS RELAY OARD T TERMINAL LOCK TL2W TERMINAL LOCK LINK 2 WAY UC8 UNIT CONTROLLER 8 Drawn: Apprvd: C.M.W. Date: 26-08-14 Title: Drawing No: Rev: 291-000-754 D HWP 59/79 & 98RKS UC8 Wiring Schematic SHEET 1 OF 1

003-000-021 06/17 www.temperzone.biz temperzone limited 2017

SPECIFICATIONS Model HWP 59CEKSY Item No. (Standard/Opposite Hand) 510-059-102 / 510-059-112 Cooling capacity (net) to AS/NZS 3823 T1 5.7 kw Heating capacity - Electric heat 3.0 kw Electrical input - cooling 1.5 kw Electrical input - heating 3.1 kw EER / AEER (cooling) 3.75 / 3.73 Unit Controller UC8 Refrigerant R410A Refrigerant charge 0.73 kg Compressor type rotary connections 1/2" male SP Nominal EWT on cooling 30 C Nominal Flow @ EWT LWT = 5k 0.34 l/s Entering system pressure drop @ nominal flow 41 kpa (6 psi) Min. water temp. Cool cycle at nominal flow 15 C Min. water temp. Cool cycle with water regulating valve 5 C Max. EWT Cool cycle at nominal flow 50 C Min. water flow @ nominal EWT 0.09 l/s Max. water pressure excluding hoses 3200 kpa (464 psi) Power supply 1 ph. 23 ac 50Hz Compressor run amps at rating cond. 6.0 A Compressor run capacitor 40 µfd Indoor fan motor size 230 W (EC) Indoor fan motor (1ph.) - full load 1.3 A Control circuit breaker (internal) 10 A Running amps (total system) 14.1 A Max. running amps (total system) 14.3 A Net weight 90 kg Accessories: Spring mounts supplied hoses 600mm long, rated 1720 kpa (250psi) 1/2" female SP, supplied Replacement filter - rated EU2/G2 119-000-086 840x265x13 Condensate lift-pump 507-003-009 Optional: SAT-3 Room temperature controller 201-000-146 TZT-100 Room temperature controller 201-000-350 Refer to temperzone for other options, eg remote sensors Tested in accordance with AS/NZS 3823 16051

DIMENSIONS (mm) PROJECTION HWP 59CEKSY Standard Not to Scale W Electrical ox X POINT LOADS (kg) W X Y Z 19 29 27 15 Note: Fan motor can be accessed from panel above, below or sides; no more than two panels at once. Z EC Motor Driver Y 46 HWP 59CEKSY Opposite Hand POINT LOADS (kg) W X Y Z W Electrical ox X 27 19 15 29 46 Note: Fan motor can be accessed from panel above, below or sides; no more than two panels at once. Z EC Motor Driver Y 139 NOTE Specifications are subject to change without notice due to the manufacturer's ongoing research and development programme.

ELECTRICAL ETH2 ETH3 ETH4 T1 T2 N T3 TL2W1 N1 CM R CAP1 T4 TL2W2 ECC driver located opposite main ebox M N2 S K 1~ T5 C L1 E ECC-240 ECH1 ECH2 EH External Protection & Isolation ETH4 PE PE ACN ACL CC ETH5 1-D A SR +12V 0-1 Optional 0-1 controls 1-D 24VAC/12VDC controls E2R Relay 2 Condensate Pump FR+ FR- MO- MO+ Use supplied resistor when wires are not fitted Relay 1 Purple Purple VC 12 VF HI ME LO C1 Flow Control Valve 5 IN#2 IN#2 IN#1 IN#1 C2 HT CP FR Pump Verification Dry Contacts 1 A1 AUX EXV2 EXV1 R Modbus slave port for MS (monitoring or control option) J1 UC8 Refer to DIP S/W settings A 5-C FLT W Red lack White 5-C T6 Flow1 Flow2 Modbus master port for optional T/stat (TZT100/SAT-3) 12 2 A2 J2 SW1 SW2 Temp Sensors (Refer to table) DP1 U V E1 DL SL Display ETH3 If Pump Verification Option fitted remove this link E 0-1 to Regulating Valve V1 V2 DEI AM SW3 E C 5-E OC IC Ferrite- coil 3 turns through ferrite core. Separarte these 3 wires from others. If Condensate Float Switch Option fitted remove this link CP4W1 D 5-E T7 Pump1 Pump2 IFM D1 D2 Pressure sensors HPT LPT Active Condensate Float Switch (Normally closed) Remote On/Off Dry Contact D3 SC C3 LOW MED HIGH CP2W1 SSR2 SSR2 SSR1 SSR1 R/V R/V ON N L C4 Ferrite- coil 4 turns through ferrite core Resistor Size (R) If Remote On/Off Option fitted remove this link HST C 1-E E2R EXV2 RELAY OARD ECC EC MOTOR CONTROLLER EH ELECTRIC HEAT EHC ELECTRIC HEAT CONTACTOR ETH EARTH FR FAULT RELAY OARD HST HIGH TEMPERATURE SAFETY THERMOSTAT IFM INDOOR FAN MOTOR K KLIXON MST MANUAL SAFETY THERMOSTAT R RESISTOR SR STATUS RELAY OARD T TERMINAL LOCK TL2W TERMINAL LOCK LINK 2 WAY UC8 UNIT CONTROLLER 8 t D 1-E MST EHC2 t TZ Motor p/n Ohms 046-000-070 62KΩ 046-000-071 62KΩ 046-000-360 3.9KΩ 046-000-361 3.9KΩ EHC1 UC8 JUMPER settings UC8 DIP switch settings Sensors (S) / Transducers (T) Name Type Colour AM Fast Temp Sensor S LACK DL Discharge Temp S RED SL Suction Temp S LUE IC Indoor Coil S YELLOW HPT High Pressure T Position Jumper J1 J2 DIP switch On/Off 1,3,4,6,13,14 On All Others Off Off CAP CAPACITOR CC CONTROL CIRCUIT REAKER CM PRESSOR MOTOR PRESSOR CONTACTOR CP2W CONNECTOR PLUG 2 WAY CP4W CONNECTOR PLUG 4 WAY REV DESCRIPTION ECN DATE APPROVED A Initial Release FR & SR now fitted as standard N3941 23-05-17 D.A.. Title: Drawing No: Rev: 291-000-798 C.M.W. Date: 29-02-16 Drawn: temperzone Ltd 2016 Client Wiring SHEET 1 OF 1 HWP 36/48 & 59CEKSY UC8 Wiring Schematic Apprvd: DO NOT SCALE - ASK

003-000-069 06/17 www.temperzone.biz temperzone limited 2017