Rooftop Packaged Unit 10kW-110kW. Vicot Air Conditioning Co., Ltd

Similar documents
Fan Coil Unit 1. BOSCH Climate Fan Coil Unit

Modular Water Cooled Water Chiller

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

Technical Manual of Oceanair Refrigeration and Air-Conditioning Series Products. Product overview

Shandong Vicot Air Conditioning Co.,Ltd. Modular&Packaged Air Cooled Water Chiller. Shandong Vicot Air Conditioning Co.,Ltd.

Vicot Air Conditioning Co., Ltd. CONTENT

tons MTZ Rooftop Units Plug and Play comfort solutions for residential and commercial application

E U R O V E N T CERTIFIED PERFORMANCE

MODEL: ACWD CEILING CONCEALED Chilled Water Fan Coils Unit

air systems Roomtop RTC-RTH 15 to 30 - L

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)


Packaged air conditioning unit condensed by air model RTC 07L to 30L. Technical information. Ref.: N

air systems Large Rooftop DIC-BIH-DIG 360 to 480 G

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

R410A50Hz Universal Outdoor Series Technical Manual

WINDOW YORK TECHNICAL GUIDE. Single package Cooling only and Heat pump. Models YO-YM R407C YO V6 G YO V7 G

Part 1 General Information... 1 Part 2 Indoor Units... 7 Part 3 Outdoor Units Part 4 Installation Part 5 Control...

ACTIVA SERIES ROOF TOP Air Conditioners 017/040

DAZZLE TM series Cassette Type Fan Coil Unit. FC-NHDU4 Cassette Type Fan Coil Unit 340~2380 m 3 /h

Product Data. Features/Benefits. 30RQ Air-cooled Modular Chiller R22 & R410A & R407C

Modular Air Cooled Scroll Chillers

1. MODELS LIST NOMENCLATURE FEATURES PRODUCT DATA FAN CHARACTERISTICS CLEARANCE DATA...

ClimaMaster Series. Rooftop Package Unit 50Hz 1311-R1211. D e a l e r i n f o r m a t i o n

CHAPTER 6 CONDENSING UNITS

Compact Horizontal Air-Air Heat Pump Model RTH 07L to 30L. Technical information. Ref.: N

MODELS LIST. Nominal Capacity RT

DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: ,

Condensing Unit Service Manual (T1/R410a/60Hz)

MAC-D R410A Series Air-cooled Modular Chiller/Heat pump

Packaged air conditioning unit condensed by air model RTC 07L to 30L. Technical information. Ref.: Y-R

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

Highly Efficient,Powerful Heating and Cooling.

MHW Air Handling Unit (50/60Hz)

SUSPENDED AIR HANDLING UNIT WITH ROTARY HEAT EXCHANGER

Product Line Introduction. Karl Zhang Technical support engineer

HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

Air treatment units 0932EN October 2017 Dehumidifier unit for radiant systems Flush-mounting installation in false ceilings

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

Compact design & easy maintenance

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

Content. Part 1 General Information Part 2 Indoor Units Part 3 Outdoor Units Part 4 Installation Part 5 Control...

E U R O V E N T CERTIFIED PERFORMANCE

MAC-A R410A Series Air cooled Modular Chiller

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42

COOLSTREAM S T A R PRODUCT OVERVIEW COOLSTREAM S T A R

ICC COOLING STORAGE UNIT ICC/ICU SYSTEM

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

TopVent Design Handbook

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

COMMERCIAL AIR CONDITIONERS. R410A All DC Inverter VRF V5 X Series 50/60Hz

MANUAL DE INGENIERIA. Part 1 General Information... 1 Part 2 Indoor Units... 6 Part 3 Outdoor Units... 30

AHU Plus. DX Air Handling Units

ED-FUW-2014 (50 Hz/60 Hz) Catalogue/Engineering Data. Large-Sized Chilled Water Fan Coil Unit (50/60 Hz) FUW040A DAIKIN INDUSTRIES, LTD.

LOW STATIC HYDRONIC DUCTED UNIT

Rif Cod i220-0

MRVIII-C MRVIII-C. 4 way air return heat exchanger design. Two stages heat exchanger design. Double EEV design. Special Heat Exchanger Design

Klimaire 16 SEER CENTRAL DUCTED YEAR. Central Air Conditioning & Heat Pump Systems Multi Position Air Handling Units LIMITED GUARANTEE

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER)

[U] Serie MHB / MHA Manual de Ingeniería

SMC DUCTED. High Performance AIR CONDITIONING SYSTEMS

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

Application guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

Integrated VarIable refrigerant flow ahu/pau (r410a)

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

AIR COOLED ROOFTOP UNITS, COOLING CAPACITY FROM 50 TO 240 kw, AIRFLOW FROM TO m3/h

Amendment Sheet. Nomenclature M 5 AC V 100 C R - F X AA. Code : M5ACV Date : Superceded : M5ACV

SINGLE SCREW AIR COOLED CHILLER-HEAT RECOVERY

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

DAIKIN Modular Inverter Air Cooled Chiller

Energy Related Products SUPER DC INVERTER SERIES

PURESTREAM CHILL-CUBE TM BY FRIULAIR

Call us today! (800)

Call us today! (800)

TECHNICAL MANUAL FOR AIR-COOLED CONDENSING UNITS MTE

ULTRA SERIES CIRCULATING AIR SOURSE HEAT PUMP WATER HEATER

TECHNICAL MANUAL. PACKAGED AIR-CONDITIONER (Split system, Air to air heat pump type) MULTI-TYPE (V-MULTI) PACKAGED AIR-CONDITIONER

JCseries EVAPORATIVE CONDENSER. engineering data

VariCool VAV Engineering Guide

3 rd Generation of VRV. The professional solution for your professional project

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

Ceiling Concealed High Volume Chilled Water Fan Coil Unit (50/60Hz)

Contents. Specifications. Description SV HP 55 SV HP 90. Specifications Warnings Introduction Overview... 4

Technical Manual. R410A 50Hz Universal Outdoor Series Inverter type. R410A50Hz Universal Outdoor Series Technical Manual LCAC/2016.

AIR CONDITIONERS LINE-UP

Swimming Pool Heat pump Instruction manual Harmo PAC series (Type ZVWX1017, ZVWX1023, ZVWX1033, ZVWX1042, ZVWX1052, ZVWX1057, ZVWX1062)

Instruction manual. Carlin Combustion Technology, Inc. 70 Maple Street East Longmeadow, MA Ph Fx

APPLICATION GUIDE FLATAIR FMC - H FIC - H FSC - H. Horizontal packaged air conditioners kw FLATAIR AGU-MSL E. lennoxemeia.

Installation and Operation Manual Package Air Conditioners

PAC, NQAC, HQAC, SQAC, EQAC AIR-COOLED CONDENSERS OPERATING AND INSTALLATION INSTRUCTIONS

AIR HANDLING UNITS MANDÍK

Transcription:

Rooftop Packaged Unit 10kW-110kW Vicot Air Conditioning Co., Ltd

ABOUT US Vicot Group is a high-tech corporation specialized in R&D, production, sales and service of renewable energy products. The corporation has almost 2000 staff and nine business divisions and/or centers as following: Solar Thermal Energy Equipment Division, Vacuum Tube Division, Gas Fired Air Conditioning Division, Electrical Air Conditioning Division, Domestic Marketing & Sales Division, Export & Import Division, Administrative & Human Resource Center, Company Management Center and General Manager Office. Our production base locates in Solar City, Dezhou, China, it covers an area of 150,000 m 2 with modern workshops and office buildings of more than 80,000 m 2. Annual yield capabilities are as follows: 100,000 electrical AC units; 10,000 gas fired AC units; 200,000 m 2 of collectors; 100,000 pieces of tubes; 5,000 standard sets of solar air conditioning system (20kW/ standard set), 200,000 standard sets of S.A.P central hot water system (10T/ standard set), 10,000 standard sets of S.A.P central distributed heating system (40kW/ standard set) and 500 standard sets of solar boiler system (700kW/ standard set). Designed annual production value reaches RMB 5 billion. With the mission of The same breath, energy saving together, the corporation realizes energy saving and environment protection by focusing on effective utilization of solar energy, air source energy, geothermal energy and other renewable energies in cooling, heating and domestic hot water fields, in pursuit of technology innovations in the field of global renewable energy utilization. After years practice in geothermal chiller & heat pump, air source chiller and heat pump and floor heating fields, Vicot accumulates rich experience in development and production and reaches a nationally advanced level. With a total investment of RMB 16 million in April 2008, after 3 years collaboration with more than 20 global universities and research institutes in sequence, Vicot successfully and innovatively launched solar air conditioning system, S.A.P central hot water system, S.A.P central distributed heating system, solar boiler system, having more than 150 patents, large scale production of them has been realized, the past and current scientists and engineers cherished wish has been realized. It places China at the world top level in solar medium temperature application field, it turns the dream into truth, for solar energy scale application in commercial and industrial field. In the meantime of developing the technology of world leading new energy product, the corporation is operated with global advanced ERP technique, UPDI\WMS barcode storage system and ABC cost control system. Information, logistics and cash flow are highly integrated, which austerely shows its concept of Quality based on science, Price optimized for customer.

Contents Rooftop Packaged Unit Introduction Features Optional free cooling Nomenclature Dimension Installation Technical specification 10 13 1 1 3 4 5

Introduction Vicot rooftop packaged units are applied in the industrial and commercial fields such as hotel, supermarkets, authorized dealing shop, office building and factory workshop. They perfectly connect many characteristic of large-sized central a/c, such as convenience, comfort, high-class, the simplicity and flexibility. The new design makes use of the space module, the features of small-sized commercial modern building space, making the cool and heat air spread into each room averagely to form Zero temperature difference. Besides, outdoor fresh air can be absorbed. The air path can connect with indoor ornament which is completely hidden and doesn t occupy any space. It has become a new generation of products of central a/c and traditional commercial a/c. Features 1. Various products and wide application The series of Rooftop units include many different specifications which can completely meet the demand of home and commercial places and offer you a comfortable and pleasant environment. 2. Complete air system, simple and hygiene, less components, easy maintenance The flexible and concise design makes the maintenance very simple. Disassembling several bolts from any side of the unit can repair any part of the unit. 3. Microcomputer intelligent controller can reach four control modes: cooling, dehumidifying, and ventilation. It also has the functions of timing on-off and failure display. 1

Rooftop Packaged Unit Features 4. Excellent performance World well-known brand of main parts are used. To guarantee the rational match of the unit, strict performance testing is done. Besides the unit runs steady and the vibration and noise are effectively controlled by the use of multi-vane pitch centrifugal fan, worldknown high efficiency compressor and the elaborative-designed controller, motor, etc. 5. Quiet operation and Convenient maintenance Reach the lowest noise of the a/c room. The a/c units are placed far from the a/c area which meets the demand of indoor low noise to the greatest degree. The adoption of high efficiency and low noise centrifugal fan makes the quiet operation come true. LCD controller Introduction Features Free cooling Nomenclature Tech. spec. Dimension Installation 2

Optional free cooling Return air damper Fresh air damper Free cooling logic: 1. When it s heating, the fresh air damper is closed, and return air damper is 100% open; 2. When it s cooling: a. When indoor room temperature (temperature set) outdoor temperature 4 o C, fresh air damper is 100% open, and return air damper is 100% closed, only the evaporator fan is running to blow air into room; b. When 0 o C indoor room temperature (temperature set) outdoor temperature< 4 o C, both fresh air damper and return air damper are closed, and the unit is not running; c. When indoor room temperature ( temperature set) outdoor temperature <0 o C, the return air damper is 100% open, and fresh air damper is 100% closed, then the compressor, condensing fan and evaporator fan will work normally to blow cool air into room. 3

Rooftop Packaged Unit Nomenclature VICOT Rooftop packaged unit N: Heat pump A: Cooling only Cooling capacity 036, 048, 060, 072, 096,125...300,360 (X 10 3 BTU/h) A: T1 (standard) C: T3 Tropical Power supply (V/Ph/Hz) 1. 208V/230V-1Ph-60Hz 2. 208V/230V-3Ph-60Hz 3. 115V-1Ph-60Hz 4. 220V/240V-1Ph-50Hz 5. 380V/415V-3Ph-50Hz 6. 420V/460V-3Ph-60Hz 7. 380V/315V-3Ph-60Hz V RP N 060 A 1 S (A) B B Air return T: Top B: Bottom L: Left R: Right F: Front Air supply T: Top B: Bottom L: Left R: Right F: Front Refrigerant type X: Standard (R22) Y: 407C Z: 410A A: Scroll compressor (std) S: Special P: Piston compressor Introduction Features Nomenclature Free cooling Tech. spec. Dimension Installation 4

Technical specification Table 1 - Cooling only 50Hz VRPA036A5 VRPA048A5 VRPA060A5 VRPA072A5 VRPA096A5 Cooling Capacity (R22) kw 10.6 14.0 17.6 21.1 28.2 Cooling Capacity (R407C)kW 10.0 13.4 16.7 20.0 26.7 Cooling Input kw 4.16 5.82 6.68 8.1 11 Circuit number Nos 1 1 1 2 2 Power V/Ph/Hz 380/3/50 Refrigerant - R22/R407c Compressor Type Hermetically Sealed Scroll Compressor Cond. fan Type Axial Drive Direct Supply fan Type Centrifugal Air flow m3/h 2100 2700 3400 4200 5200 Max ESP Pa 50 50 50 150 150 Noise db(a) 57 58 59 63 64 Ref. Charge Kg 1.6 2.0 2.2 2.7 X 2 3.0 X 2 L (mm) 1150 1150 1150 1685 1685 Dimension W (mm) 735 735 735 1110 1110 H (mm) 850 850 850 1045 1045 Weight Kg 160 170 170 260 310 NOTES: Cooling conditioning: Indoor temperature DB: 27 o C, WB: 19 o C; Outdoor temperature DB: 35 o C,WB: 24 o C. VRPA125A5 VRPA168A5 VRPA250A5 VRPA300A5 VRPA360A5 Cooling Capacity (R22) kw 36.7 49.3 73.3 88.0 105.5 Cooling Capacity (R407C)kW 34.8 46.8 69.6 83.6 100.3 Cooling Input kw 13.1 18.72 29.12 35.36 41.6 Circuit number Nos 2 2 2 2 2 Power V/Ph/Hz 380/3/50 Refrigerant - R22/R407c Compressor Type Hermetically Sealed Scroll Compressor Cond. fan Type Axial Drive Direct Supply fan Type Centrifugal Air flow m3/h 6000 8000 12500 17000 21800 Max ESP Pa 250 250 250 300 300 Noise db(a) 65 68 72 75 77 Ref. Charge Kg 4.8 2 6.3+3.5 7.6x2 9x2 10x2 L (mm) 2010 2010 2845 3445 3445 Dimension W (mm) 1165 1165 2115 2115 2115 H (mm) 1155 1155 1195 1195 1195 Weight Kg 384 600 860 1400 1480 NOTES: Cooling conditioning: Indoor temperature DB: 27 o C, WB: 19 o C; Outdoor temperature DB: 35 o C,WB: 24 o C. 5

Rooftop Packaged Unit Technical specification Table 2 - Cooling only 60Hz VRPA072A2 VRPA096A2 VRPA125A2 VRPA168A2 VRPA250A2 Cooling Capacity (R22)kW 21.1 28.2 36.7 49.3 73.3 Cooling Capacity (R407C)kW 20.0 26.7 34.8 46.8 69.6 Cooling Input kw 8.42 11.44 13.1 18.72 29.12 Circuit number Nos 2 2 2 2 2 Power V/Ph/Hz 220/3/60 Refrigerant - R22/R407c Compressor Type Hermetically Sealed Scroll Compressor Cond. fan Type Axial Drive Direct Supply fan Type Centrifugal Air flow m3/h 4200 5200 6000 8000 12500 Max ESP Pa 150 150 250 250 250 Noise db(a) 63 64 65 68 72 Ref. Charge kg 2.7 2 3.0 2 4.8 2 6.3+3.5 7.6x2 Length 1685 1685 2010 2010 2845 Dimension(mm) Width 1110 1110 1165 1165 2115 Height 1045 1045 1155 1155 1195 Weight Kg 260 310 384 600 860 NOTES: Cooling conditioning: Indoor temperature DB: 27 o C, WB: 19 o C; Outdoor temperature DB: 35 o C,WB: 24 o C. VRPA300A2 VRPA360A2 Cooling Capacity (R22)kW 88.0 105.5 Cooling Capacity (R407C)kW 83.6 100.3 Cooling Input kw 35.36 41.6 Circuit number Nos 2 2 Power V/Ph/Hz 220/3/60 Refrigerant - R22/R407c Compressor Type Hermetically Sealed Scroll Compressor Cond. fan Type Axial Drive Direct Supply fan Type Centrifugal Air flow m3/h 17000 21800 Max ESP Pa 300 300 Noise db(a) 75 77 Ref. Charge kg 9x2 10x2 Length 3445 3445 Dimension(mm) Width 2115 2115 Height 1195 1195 Weight Kg 1400 1480 Introduction Features Nomenclature Free cooling Tech. spec. Dimension Installation NOTES: Cooling conditioning: Indoor temperature DB: 27 o C, WB: 19 o C; Outdoor temperature DB: 35 o C,WB: 24 o C. 6

Technical specification Table 3 - Heat pump 50Hz VRPN036A5 VRPN048A5 VRPN060A5 VRPN072A5 VRPN096A5 Cooling Capacity (R22)kW 10.6 14.0 17.6 21.1 28.2 Cooling Capacity (R407C)kW 10.0 13.4 16.7 20.0 26.7 Heating Capacity (R22)kW 11.0 15.6 18.0 21.6 28.7 Heating Capacity (R407C)kW 10.4 14.8 17.2 20.6 27.2 Cooling Input kw 4.16 5.82 6.86 8.42 11.44 Heating Input kw 3.75 4.89 6.19 8.22 10.92 Circuit number Nos 1 1 1 2 2 Power V/Ph/Hz 380/3/50 Compressor Type Hermetically Sealed Scroll Compressor Cond. fan Type Direct drived axial fan Supply fan Type Direct drived centrifugal fan Air flow m3/h 2100 2700 3400 4200 5200 Max ESP Pa 50 50 50 150 150 Noise db(a) 57 58 59 63 64 Ref. Charge Kg 2.5 3.1 3.8 2.7 2 3.0 2 Length 1300 1300 1300 1685 1685 Dimension(mm) Width 970 970 970 1110 1110 Height 790 790 790 1045 1045 Weight Kg 165 210 210 260 310 NOTES: Cooling conditioning: Indoor temperature DB: 27 o C, WB: 19 o C; outdoor temperature DB: 35 o C,WB: 24 o C. Heating conditioning: Indoor temperature DB: 20 o C, WB: 15 o C; outdoor temperature DB: 7 o C,WB: 6 o C. VRPN125A5 VRPN168A5 VRPN250A5 VRPN300A5 VRPN360A5 Cooling Capacity (R22)kW 36.7 49.3 73.3 88.0 105.5 Cooling Capacity (R407C)kW 34.8 46.8 69.6 83.6 100.3 Heating Capacity (R22)kW 37.4 50.4 75.3 89.4 107.3 Heating Capacity (R407C)kW 35.6 47.8 71.5 85.0 102.0 Cooling Input kw 13.1 18.72 29.12 35.36 41.6 Heating Input kw 12.7 17.89 27.9 37.4 43.7 Circuit number Nos 2 2 2 2 2 Power V/Ph/Hz 380/3/50 Compressor Type Hermetically Sealed Scroll Compressor Cond. fan Type Direct drived axial fan Supply fan Type Direct drived centrifugal fan Air flow m3/h 6000 8000 12500 17000 21800 Max ESP Pa 250 250 250 300 300 Noise db(a) 65 68 72 75 77 Ref. Charge Kg 4.8 2 6.5+3.7 7.6 2 9 2 10 2 Length 2010 2010 2845 3445 3445 Dimension(mm) Width 1165 1165 2115 2115 2115 Height 1155 1155 1195 1195 1195 Weight Kg 384 600 860 1500 1580 NOTES: Cooling conditioning: Indoor temperature DB: 27 o C, WB: 19 o C; outdoor temperature DB: 35 o C,WB: 24 o C. Heating conditioning: Indoor temperature DB: 20 o C, WB: 15 o C; outdoor temperature DB: 7 o C,WB: 6 o C. 7

Rooftop Packaged Unit Technical specification Table 4 - Heat pump 60Hz VRPN072A2 VRPN096A2 VRPN125A2 VRPN168A2 VRPN250A2 Cooling Capacity (R22)kW 21.1 28.2 36.7 49.3 73.3 Cooling Capacity (R407C)kW 20.0 26.7 34.8 46.8 69.6 Heating Capacity (R22)kW 21.6 28.7 37.4 50.4 75.3 Heating Capacity (R407C)kW 20.6 27.2 35.6 47.8 71.5 Cooling Input kw 8.42 11.44 13.1 18.72 29.12 Heating Input kw 8.22 10.92 12.7 17.89 27.9 Circuit number Nos 2 2 2 2 2 Power V/Ph/Hz 220/3/60 Compressor Type Hermetically Sealed Scroll Compressor Cond. fan Type Direct drived axial fan Supply fan Type Direct drived centrifugal fan Air flow m3/h 4200 5200 6000 8000 12500 Max ESP Pa 150 150 250 250 250 Noise db(a) 63 64 65 68 72 Ref. Charge Kg 2.7 2 3.0 2 4.8 2 6.5+3.7 7.6x2 Length 1685 1685 2010 2010 2845 Dimension(mm) Width 1110 1110 1165 1165 2115 Height 1045 1045 1155 1155 1195 Weight Kg 260 310 384 600 860 NOTES: Cooling conditioning: Indoor temperature DB: 27 o C, WB: 19 o C; outdoor temperature DB: 35 o C,WB: 24 o C. Heating conditioning: Indoor temperature DB: 20 o C, WB: 15 o C; outdoor temperature DB: 7 o C,WB: 6 o C. VRPN300A2 VRPN360A2 Cooling Capacity (R22)kW 88.0 105.5 Cooling Capacity (R407C)kW 83.6 100.3 Heating Capacity (R22)kW 89.4 107.3 Heating Capacity (R407C)kW 85.0 102.0 Cooling Input kw 35.36 41.6 Heating Input kw 37.4 43.7 Circuit number Nos 2 2 Power V/Ph/Hz 220/3/60 Compressor Type Hermetically Sealed Scroll Compressor Cond. fan Type Direct drived axial fan Supply fan Type Direct drived centrifugal fan Air flow m3/h 17000 21800 Max ESP Pa 300 300 Noise db(a) 75 77 Ref. Charge Kg 9x2 10x2 Length 3445 3445 Dimension(mm) Width 2115 2115 Height 1195 1195 Weight Kg 1500 1580 NOTES: Cooling conditioning: Indoor temperature DB: 27 o C, WB: 19 o C; outdoor temperature DB: 35 o C,WB: 24 o C. Heating conditioning: Indoor temperature DB: 20 o C, WB: 15 o C; outdoor temperature DB: 7 o C,WB: 6 o C. Introduction Features Nomenclature Free cooling Tech. spec. Dimension Installation 8

Technical specification Table 5 - T3 Tropical VRPA036C5 VRPA048C5 VRPA060C5 VRPA072C5 VRPA096C5 Cooling kw(a) 9.0 12.0 15.0 18.0 24.0 Capacity-R22 kw(b) 8.6 11.4 14.2 17.0 22.8 Cooling Input kw(a) 4.3 6.1 7.1 8.8 11.9 kw(b) 4.5 6.3 7.4 9.1 12.35 Circuit number Nos 1 1 1 2 2 Power V/Ph/Hz 380/3/50 Refrigerant - R22/R407c Compressor Type Hermetically Sealed Scroll Compressor Cond. fan Type Direct drived axial fan Supply fan Type Direct drived centrifugal fan Air flow m3/h 2100 2700 3400 4200 5200 Max ESP Pa 50 50 50 150 150 Noise db(a) 57 58 59 63 64 Ref. Charge Kg 1.6 2 2.2 2.7 2 3.0 2 Length 1150 1150 1150 1685 1685 Dimension(mm) Width 735 735 735 1110 1110 Height 850 850 850 1045 1045 Weight Kg 160 170 170 260 310 NOTES: Cooling conditioning: Indoor temperature DB: 29 o C, WB: 19 o C; Outdoor temperature (A)DB: 35 o C,WB: 24 o C. (B):DB: 46 o C,WB: 24 o C. VRPA125C5 VRPA168C5 VRPA250C5 VRPA300C5 VRPA360C5 Cooling kw(a) 31.2 41.9 62.3 74.8 89.7 Capacity-R22 kw(b) 29.6 39.8 59.2 71.0 85.2 Cooling Input kw(a) 13.6 19.5 30.2 36.8 43.2 kw(b) 14.15 20.2 31.45 38.2 45.0 Circuit number Nos 2 2 2 2 2 Power V/Ph/Hz 380/3/50 Refrigerant - R22/R407c Compressor Type Hermetically Sealed Scroll Compressor Cond. fan Type Direct drived axial fan Supply fan Type Direct drived centrifugal fan Air flow m3/h 6000 8000 12500 17000 21800 Max ESP Pa 250 250 250 300 300 Noise db(a) 65 68 72 75 77 Ref. Charge Kg 4.8 2 6.3+3.5 7.6x2 9x2 10x2 Length 2010 2010 2845 3445 3445 Dimension(mm) Width 1165 1165 2115 2115 2115 Height 1155 1155 1195 1195 1195 Weight Kg 384 600 860 1400 1480 NOTES: Cooling conditioning: Indoor temperature DB: 29 o C, WB: 19 o C; Outdoor temperature (A)DB: 35 o C,WB: 24 o C. (B):DB: 46 o C,WB: 24 o C. 9

Rooftop Packaged Unit Dimension VRPA(N)036 VRPA(N) 048 & VRPA(N)060 Introduction Features Nomenclature Free cooling Tech. spec. Dimension Installation 10

Dimension VRPA(N)072 & VRPA(N)096 VRPA(N)125& VRPA(N)168 11

Rooftop Packaged Unit Dimension VRPA(N)250 VRPA(N)300 & VRPA(N) 360 Introduction Features Nomenclature Free cooling Tech. spec. Dimension Installation 12

Notice Installation 1) Aptitude The equipment installation must be completed by professionals. Installation by non-professional staff may lead to improper operation, even failure. 2) Acceptance Check the unit carefully when receiving the units to see if any failure occurs in the process of transportation. Check the amount of equipments and accessories. Contact the relevant staff if any problem occurs. 3) Move Take necessary protection to the unit when moving the units. It is not allowed to make forcible operation to damage the units. 4) Method of dismantle the road wheel a) dismantle the leathern bar b) take out the road wheel Unit installation 1) The installation location should make the hot air through condenser not to be absorbed back to the unit or absorb hot air which comes from another unit. Besides, enough space should be kept for unit maintenance. 2) Barrier should not exist to block the air discharge and air suction in the passage of air discharge and air suction of the units. 3) There should be good ventilation at the location of unit installation so as to take away the heat air blown from the unit and bring in the air at a lower temperature. 4) The unit should be installed on a base which is firm and flat, 50-100mm higher than the plane. Enough strength should be kept to support the weight of the unit and the vibration when running. 5) The unit should be installed horizontally to decrease the vibration, lower the noise and make the condensing water discharge smooth. The condensing water discharge vent of the unit must have water seal whose height should be more than 50mm. 6) Keep the installation away from the dirty or oily place so as not to block the heat exchanger. 7) Following space is suggested during installation. 036 048 060 072 096 125 168 250 300 360 A 500 500 500 1200 1200 1600 1600 2000 2500 2500 B 500 500 500 500 500 500 500 800 1200 1200 C 500 500 500 2000 2000 2000 2000 2000 2500 2500 D 300 300 300 1200 1200 1600 1600 2000 2500 2500 13

Rooftop Packaged Unit Installation Duct installation 1) Usually two air supply ducts: Rectangle air duct and circular one. 2) Rectangle air duct can connect the air supply inlet of the indoor unit by flexible connection. 3) For circular duct, add a transition duct to the air inlet of indoor unit, and be connected separately to air diffuser, (referring to the drawing),the air inlet velocity of air diffuser should be the same to meet the requirement. 4) Suggest using silencer box in the air supply duct of the heavy airflow unit for lower noise. Name 1 Main pipe 2 Branch pipe 3 Air supply pipe 5) If adopting fresh air, the fresh air entrance is better to choose the place where the air is clean and there is no pollution. As for the outdoor air entrance, rain-proof shutter and filter should be installed and at the fresh air section, air flow adjuster should be installed. It is suitable when the fresh air quantity makes up 10% of the total air quantity. Air duct heat preservation Introduction Features Nomenclature Free cooling Tech. spec. Dimension Installation Air supply and air return pipes should both have heat preservation. First of all, stick the nail on the air duct and then attach the cotton preservation with tin foil paper. Fasten it with nails and seal the connection with tin foil adhesive tape. 14

Installation Name 1 Galvanized plate 2 nail 3 Co on preserva on 4 Tin foil 5 Nail cover 6 Adhesive tape Remarks: 1. Every air supply pipe and return air pipe should have iron bracket fastened on the floor prefabricated board. The air duct connector should be sealed tight by adhesive tape. 2. It is recommended that the air return margin should keep the wall 150mm far. Electrical installation Notice: 1) The power supply capacity must meet the a/c requirement. The voltage at the side of the power supply incoming line inside the a/c unit should remain within +10% rating and the power supply frequency is within 2%. 2) Cut the power supply at electric wire connection. Forbidden to operate with electricity. 3) To protect the staff and avoid the danger of electric shock caused by leakage, the unit body should have good and reliable grounding protection setting to prevent the electric shock accident. It also needs check the grounding line very often to guarantee a good grounding(grounding resistance should not exceed 4 ohm) 4) The layout of power supply routing must conform to the national standard and the unit body must have good grounding to avoid the danger caused by insulation failure. The indoor suspending routing adopts electric specialized PVC conduit tube and PVC connection wire box with cover (not use recycling material connection wire box) Wiring conduit should flat and erect and be fixed. Threading pipe should not use right angle elbow plumbing, but use proper siphon spring bend. The radius of the syphon should be more than four times as long as the diameter of the conduit. Drape should not occur after bending the threading pipe. Lay the connection box properly so as to easy maintenance and wire changeover. 5) The communication wire (Temp. Probe connection wire) and the power supply source should be laid separately to prevent interruption. 15 28

Rooftop Packaged Unit Installation Maintenance 1) The on-off of the unit per hour should not exceed four times, otherwise the service life of the unit will decrease. 2) The surroundings of the units should keep clean and tidy. Clean the leaves and rubbish absorbed by the fin on time. 3) Clean the air return filter once three months to guarantee the quality of the air. 4) Check if the condensing water pipe is smooth regularly. Make sure the drainage is clear. 5) Not allowed to reset the unit by force without any reason of the trouble if something is wrong with the unit. Contact the agent or the technician. 6) All diameters have been setup at the ex-work of the units. If the customer needs to adjust the diameter, please contact the agent and the technician. It is not allowed to adjust the diameter automatically. Introduction Features Nomenclature Free cooling Tech. spec. Dimension Installation 16

The Same Breath, Energy Saving Together. VICOT AIR CONDITIONING CO., LTD Add: Hongdu Road, Dezhou Eoonomic Development Zone, Shandong Province, China. Post Code: 253022 Sales Tel: +86-8235 5566/68/76 Fax: +86-8235 7911 Email: export@vicot.com.cn Http://www.vicot com cn 2014.01 Vicot reserves the right of modification without prior notice