Model: Slimline-N. 1 Slimline Series

Similar documents
Model : PRT-EN Model: PRT-EN1

Underfloor Heating Programmable Thermostat

: PRT / PRT PRT / PRT-N1

Table of Contents. SLIMLINE Series MODEL: SLIMLINE

Model: PRT-TS / PRT-NTS

Model: Slimline-RF. 1 Slimline Series

Model: Slimline-B. Battery Series

12V. Model: Available in : Sapphire Black and Glacier White. 2 Series

Model: Available in : Sapphire Black and Glacier White. 1 Series

Model: 1 Series 12V. Available in: Sapphire Black and Glacier White

Table of Contents. Model: Series. Available in : Sapphire Black and Glacier White. Product Image. 20 Table of Contents.

Model: PRT2-TS / PRT2-NTS EU. Model: Touch Duo

Model: Touch-RF. 1 Wireless Series

Operating Instructions Model: PRT-RP Version 3. 05/11 Revision 2 Ref: PRTRP

Model: Touch-RS. 1 Touch-RS

Model: Available in: Sapphire Black and Glacier White. 1 Series

Table of Contents. Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure

PRT-TS WiFi PRT-TS WiFi

Table of Contents. Product Image 1 Locking/Unlocking the neoair 24 Table of Contents 2 Frost Protection 25 What is a Programmable Room Thermostat?

50110_HM-neoStat-2014_Layout 1 31/10/ :33 Page 1 neo

Operating Instructions Model: PRT/HW - PRT/HW-N Version 3. 09/09 Revision 2 Ref: PRT/HW/NV3

Model: Edge-HC. 1 edge-hc

Uponor Comfort-E Thermostat Dig. Prog Set T-86 INSTALLATION AND OPERATION MANUAL

Operating Instructions

Operating Instructions Model: PRT-TS WiFi RF. 01/13 Version 1 Ref: PRT-TSWIFI RF

Operating Instructions Model : HC HC-N

CS027 User Instructions

MAKING MODERN LIVING POSSIBLE. TP7001 Range Electronic 7 Day Programmable Room Thermostat. User Guide. Danfoss Heating

Drayton Digistat +3RF

C-Stat 17-ZW User Instructions

Model: RT510RF. Installation Manual

CentaurStat 7 User Operating Instructions Central Heating Programmable Room ThermoStat

Type UCG/UDG. English...1 Français...7 Español Up button. OK button. Down button

AUTO CM CM USER GUIDE

Digital Room Thermostat

DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat

CM707. Programmable Room Thermostat with Optimum Start, Optimum Stop and Delayed Start. User Guide

User Manual THR870CUK Programmable Thermostat

Model: RT310. Installation Manual

Elegance. SMT-700 User manual. Ver

ThermoPlus AS2-RF & ASR-RF Installation Instructions

Battery Powered Electronic Programmable Room Thermostat Cat. No. TRT035. Operating & Installation Instructions

Battery Powered Electronic Programmable Room Thermostat

- Brochure D 542. Introduction. Features. tekmarnet 4 Thermostat /05. 5 Data Brochure Control settings wiring instructions

User Guide for EHE & EHE Programmable Room Thermostat

SAT-3 Room Temperature Controller

irad Wireless Controller

Evolution Control. Zone Control Homeowner s Guide

ECO AND DATE /06 ARTWORK DESCRIPTION. 22 page A6 : Saddle stitch (2-wire) 6 page : 4 colour : 170gsm Silk 18 page : 1 colour : 100gsm Silk

DIGISTAT PROGRAMMABLE 24 HOUR ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat.

ESRTPRF. Wireless Programmable Room Thermostat, with Delayed & Optimum Start. User and Installation Instructions M/A MANUAL

RF Programmable Room Thermostat User Instructions

ELECTRONIC THERMOSTAT

- Data Brochure tekmarnet 4 Thermostat 542e

MCD User Manual

Cat No. 099A. Digital Programmable Thermostat for Weekday/Weekend Setting. User Maunal

3 Channel Multi-Purpose Programmer User Instructions

Parts Diagram. Up button. Down button. Right (fan) button. Left (system) button. RC/RH Jumper. Field programming pins

RT021 User and Installation Instructions

Vokèra OpenTherm 711 with external sensor connected

Infinity Control. Homeowner s Guide. The New Feeling of Comfort

CoziStat. 1. Introduction and Brief Description COZISTAT INSTALLATION I NSTRUCTIONS &OPERATING MANUAL

Programmable Thermostat

User Manual THR872CUK Wireless Programmable Thermostat

User Manual for the. ACCS-1 Digital 7 Day Programmable Thermostat with Zone Control

Energy Plannersm Programmable Thermostat Customer Guide. Take control of your comfort and energy savings

ES3247B. 3 Channel Programmer. User and Installation Instructions

CM921 - User Guide 1 day Wireless Programmable Room Thermostat with LoT technology

Model: RT310RF. Installation Manual

USER'S OPERATING INSTRUCTIONS

Owner s Manual. Part Number 33CSCPACHP-01

Owner s Manual MODEL 8555

Spectrolink Comfort Controller. Home Owner's Manual Heating. baby, outside. Come home to ECOST R

TB8220U Commercial Programmable Thermostat OWNER S GUIDE

Vokèra OpenTherm 711 without external sensor connected

Phone-A-Stat. MODEL Command Center With Thermostat Operation, Maintenance & Installation Manual. Introduction.

ETN-24-SUPER-PROG (US Program - Celsius)

MC200. Users Instructions. HEATING DIVISION Hort Bridge Ilminster, Somerset TA19 9PS Tel: Fax:

INSTALLATION MANUAL. Need Help? This manual covers the following models: T915. Power Type. Thermostat Applications Guide. Page.

User Guide Y9420H Sundial RF 2 Pack 2

MAKING MODERN LIVING POSSIBLE RET2000 B/M/MS. Electronic digital thermostat with LCD User Guide. Danfoss Heating

SAS6000UTK-7 UNIVERSAL THERMOSTAT

Please read this manual carefully before installation and use.

4 in 1 Digital Thermostat Control

YEAR-ROUND COMFORT EVOLUTION CONTROL ZONE CONTROL HOMEOWNER S GUIDE. The Ultimate Home Comfort System.

ERV-24. Technician Settings & Operating Manual. Protected by one or more of the following patents: US 5,547,017; 5,881,806; 6,431,268; CA 2,245,135

INSTALLATION MANUAL. Need Help? This manual covers the following models: T755. Power Type. Thermostat Applications Guide. Page.

Contents. Box contents: JGSTAT2B (Black) Fixing screws (White) Icons used in this manual:

INSTALLATION MANUAL. * If using remote sensors the thermostat must be hardwired. Need Help?

Digital Thermostat Models: VS30W and VS30B

Installation and user manual

COMF RT SYSTEM. T-32-TS Touchscreen Thermostat. User Manual

1 For All Programmable Digital Thermostat

Digital Room Thermostat with TPI & Delayed Start User Instructions

Safety & Installation Instructions

Owner s Manual. Digital Thermostat. Heat/Cool & Heat Pump 7-Day Programmable S1-THEM22P7S COMMERCIAL. Model HVAC SERVICE PARTS

On initial power up the thermostat will guide you through set up procedure for the following:

User Manual THR842DUK Wireless Digital Thermostat

OWNER S MANUAL Venstar Inc. 08/07

4 Wiring Brochure Wiring and

Transcription:

Model: Slimline-N

Model: Slimline-N 1 Slimline Series

Table of Contents Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure LCD Display Operating Mode Setting the Clock Temperature Display Setting the Comfort Levels Locking the Thermostat 1 2 3-4 5-6 7-8 9 10 11 12-13 14 Temperature Control Temperature Hold Holiday Mode Frost Protection Heating On/Off Optional Features Explained Error Codes Re-calibrating the Thermostat Factory Reset Wiring Diagrams Notes 15 16 17 18 19 20-23 24 25 26 27-28 29-31 Model: Slimline-N 2

What Section is a Header Programmable Room Thermostat? A programmable room thermostat is both a programmer and a room thermostat. A programmer allows you to set On and Off periods to suit your own lifestyle. A room thermostat works by sensing the air temperature, switching on the heating when the air temperature falls below the thermostat setting, and switching it off once this set temperature has been reached. So a programmable room thermostat lets you choose what times you want the heating to be on, and what temperature it should reach while it is on. It will allow you to select different temperatures in your home at different times of the day (and days of the week) to meet your particular needs and preferences. Setting a programmable room thermostat to a higher temperature will not make the room heat up any faster. How quickly the room heats up depends on the design and size of the heating system. Similarly reducing the temperature setting does not affect how quickly the room cools down. Setting a programmable room thermostat to a lower temperature will result in the room being controlled at a lower temperature, and saves energy. 3 Slimline Series

Section Header The way to set and use your programmable room thermostat is to find the lowest temperature settings that you are comfortable with at the different times you have chosen, and then leave it alone to do its job. The best way to do this is to set the room thermostat to a low temperature say 18 C, and then turn it up by 1 C each day until you are comfortable with the temperature. You won t have to adjust the thermostat further. Any adjustment above this setting will waste energy and cost you more money. You are able to temporarily adjust the heating program by overriding or using the temperature hold feature. These features are explained further on pages 14 and 15 of this manual. Programmable room thermostats need a free flow of air to sense the temperature, so they must not be covered by curtains or blocked by furniture. Nearby electric fires, televisions, wall or table lamps may also prevent the thermostat from working properly. Model: Slimline-N 4

Installation Section Header Procedure Do Mount the thermostat at eye level. Read the instructions fully so you get the best from our product. Don t Do not install near to a direct heat source as this will affect functionality. Do not push hard on the LCD screen as this may cause irreparable damage. This Slimline Series thermostat is designed to be flush mounted and requires a back box of 35mm (minimum depth) to be sunk into the wall prior to installation. Step 1 Carefully separate the front half of the thermostat from the back plate by placing a small flat head terminal driver into the slots on the bottom face of the thermostat. Step 2 Place the thermostat front somewhere safe. Terminate the thermostat as shown in the diagrams on pages 26-27 of this booklet. Step 3 Screw the thermostat back plate securely into the back box. Step 4 Clip the front of the thermostat back onto the thermostat back plate. 5 Slimline Series

1 Section Header 2 3 4 Model: Slimline-N 6

1 2 3 4 5 6 Section Header 13 7 8 9 10 11 12 7 Slimline Series

LCD Section Display Header 1. Room/Floor Temp - Indicates the current temperature sensor mode. 2. Day Indicator - Displays the current day. 3. Frost Icon - Displayed when the thermostat is in frost protection mode. 4. Flame Icon - Displayed when the thermostat is calling for heat, the flame icon will flash when the optimum start function is in operation. 5. Floor Temp Limit Icon - Displayed when the floor sensor probe has reached the temperature limit set on feature 09. 6. Temperature Hold - When a Temp Hold is active, HOLD FOR and the remaining time period is displayed. 7. Set - Indicates when changes are being made to programs or temperature set points. 8. Holiday Indicator - Displayed when the thermostat is in holiday mode. 9. Current Temp - Indicates the current sensor temperature. 10. Program Cycle Indicator - Displayed during programming only to show which period is being altered. 11. Keypad Lock Indicator - Displayed when the keypad is locked. 12. Units of Temperature - Degrees Celsius or Fahrenheit. 13. Clock - Digital clock display in 24h format. Model: Slimline-N 8

Section Header Operating Mode The thermostat has 4 main operating modes: MODE 00 01 02 03 DESCRIPTION Non-programmable with air sensor only. Non-programmable with floor / air sensor options. Programmable with air sensor only. Programmable with floor / air sensor options (default). Select the mode that best suits your needs Mode 00 or 02 MUST NOT be used to control electric underfloor heating, Mode 01 or 03 (default) with floor sensor option must be used. Press and hold the Power button to turn the thermostat OFF... Press and hold the H key for 10 seconds... Use the Up/Down keys to select the mode you require... Press A to confirm settings... Press the Power button once to turn the thermostat back ON... 9 Slimline Series

Setting Section the Header Clock To set the clock, follow these steps. With the thermostat turned ON, press the Clock key twice... Use the Up/Down keys to set the hours... Press H to confirm settings... Use the Up/Down keys to set the minutes... Press H to confirm settings... Use the Up/Down keys to set the day of the week... Press A to confirm settings and return to main display... Day Hours Minutes Model: Slimline-N 10

Temperature Section Header Display This thermostat can be setup to use an air sensor, floor sensor or both. The display will clearly show which sensor is being controlled by showing either: Room Temperature Floor Temperature Note: Built in air sensor only MUST NOT be used to control electric underfloor heating. Floor sensor only or built in air & floor sensor together must be used. When the thermostat is set to use both sensors, the room temperature will be displayed. To view the floor temperature, press and hold the key until the Floor Temp is displayed on screen. 11 Slimline Series

Setting Section the Header Comfort Levels The thermostat provides Weekday/Weekend or 7 Day Programming options. You should consult the Optional Features section to select the required mode. The thermostat is supplied with comfort levels already programmed, but these can be changed easily. The default times and temperatures are; 08.00-21 C (Wake) 09.30-16 C (Leave) 16.30-22 C (Return) 23.00-17 C (Sleep) If you only want to use 2 levels, you should program the unused levels to --.-- Note: For Weekday/Weekend programming, the 4 comfort levels are the same for all weekdays but can be different for the weekends. For 7 Day programming, each day can have 4 different comfort levels. To program comfort levels, press Clock once... For Weekday/Weekend programming, Mon Tue Wed Thu Fri are displayed on screen. For 7 Day programming, only Mon is displayed in the day indicator field. Model: Slimline-N 12

Section Header Use the Up/Down keys to enter the required WAKE time... Press H to confirm settings... Use the Up/Down keys to enter the required WAKE temperature... Press H to confirm settings... You will now see LEAVE displayed on screen. Repeat the programming steps for each period until complete. For unused periods enter --.-- and the thermostat will ignore the setting. Press A to confirm settings and return to main display... Note: In 7 Day programming mode you can repeat for each day independently. In Weekday/Weekend programming mode you will see Sat Sun displayed on screen and can repeat for the weekdays. To change the programming mode please refer to pages 21-22. 13 Slimline Series

Locking Section Header the Thermostat The thermostat has a keypad lock facility. To activate the lock follow these steps. Press and hold the A and Down keys together for 10 seconds... You will see the lock symbol appear on screen... To unlock, repeat the steps above until the lock symbol disappears. Note: The keypad lock indicator is only displayed when the lock is active. Keypad Lock Indicator Model: Slimline-N 14

Temperature Section Header Control The Up/Down keys allow you to adjust the set temperature... When you press either key, you will see the word SET and the desired temperature will be displayed on screen. Use the Up/Down keys to adjust the SET value... Press A to confirm settings and return to main display... Note: This override will be maintained until the next programmed comfort level. Set Temperature Set Icon 15 Slimline Series

Temperature Section Header Hold The temperature hold function allows you to manually override the current operating program and set a different temperature for a desired period. Press H to commence temperature hold... Use the Up/Down keys to enter the required Hold time... Press H to confirm settings... Use the Up/Down keys to enter the required Hold temperature... Press A to confirm settings and return to main display... You will see the HOLD FOR indication is displayed on screen. The time will countdown the set duration and then revert to the normal program. Hold ON Indicator Hold Time Remaining To cancel temperature hold, follow the same steps but reduce the hold time to 00:00 hours. Model: Slimline-N 16

Holiday Section Mode Header The holiday function reduces the set temperature in your home to the frost protection temperature setting (see page 20). The thermostat will maintain this temperature for the duration of the holiday and will then automatically return to the program schedule on your return. Press H three times (until you see the suitcase on screen)... Use the Up/Down keys to enter the number of days holiday... Press A to confirm settings and return to main display... The display will show a suitcase indicating the thermostat is in holiday mode. Note: A holiday period does not start until 00:00 the next day. For example, if you set a holiday period on Friday for 2 days, Saturday will be counted as the first day and the thermostat will revert back to the programmed schedule at 00:00 on Monday. Holiday Days To cancel, follow the same steps but reduce the holiday duration to 00 days. 17 Slimline Series Holiday ON Indicator

Frost Section Protection Header Pressing the button once will place the thermostat in frost protect mode. In this mode, the thermostat will display the frost icon and will only turn the heating on should the room temperature drop below the set frost temperature (see page 19). Should the heating be turned on whilst in frost protect mode, the flame icon will be displayed. To cancel the frost protect mode, press the button once again. Frost Protection Mode Enabled Model: Slimline-N 18

Heating Section Header On/Off The heating is indicated ON when the flame icon is displayed. When the flame icon is absent, there is no requirement for heating to achieve the set temperature but the thermostat remains active. To turn the thermostat OFF completely, press and hold the Power button... The display and heating output will be turned OFF completely.* To turn the thermostat back ON, press the Power button once again... Thermostat completely OFF Thermostat powered ON *See Feature 3 on page 20 19 Slimline Series

Optional Section Header Features Explained THE FOLLOWING SETTINGS ARE OPTIONAL AND IN MOST CASES NEED NOT BE ADJUSTED Feature 01 - Temperature Format: This function allows you to select between C and F. Feature 02 - Switching Differential: This function allows you to increase the switching differential of the thermostat. The default is 1 C which means that with a set temperature of 20 C, the thermostat will switch the heating on at 19 C and off at 20 C. With a 2 C differential, the heating will switch on at 18 C and off at 20 C. Feature 03 - Frost Protect: You can set whether the thermostat will maintain the frost temperature when the thermostat display is turned off. As a default, this is enabled. Feature 04 - Frost Protect Temperature: This is the temperature maintained when the thermostat is in frost protect mode. The range is 07-17 C. The default is 12 C and is suitable for most applications. Feature 05 Output Delay: To prevent rapid switching, an output delay can be entered. This can be set from 00-15 minutes. The default is 00 which means there is no delay. Feature 06 Communication Address: This setting is used when you have connected your thermostat to a network system. Each thermostat on the network must have a unique communication address. This can be set from 01-32. Feature 07 Temperature Up/Down Limit: This function allows you to limit the use of the up and down keys. This limit is also applicable when the thermostat is locked and so allows you to give others limited control over the heating system. Model: Slimline-N 20

Feature 08 Sensor Selection: On this thermostat, you can select which sensor should Section be used. You can Header select between air temperature only, floor temperature, or both. When you enable both sensors, the floor sensor is used as a floor limiting sensor and is designed to prevent the floor from overheating. Note: Built in air sensor only MUST NOT be used to control electric underfloor heating. Floor sensor only or built in air & floor sensor together must be used. Feature 09 Floor Temp Limit: This function is available when mode 08 is set to 02, 03 or 04. You can set a floor limiting temperature between 20-45 C (27 C is the default). Feature 10 Optimum Start: Optimum start will delay the start up of the heating system to the latest possible moment to avoid unnecessary heating and ensure the building is warm at the programmed time. The thermostat uses the rate of change information to calculate how long the heating needs to raise the building temperature 1 C (with a rate of change of 20, the thermostat has calculated the heating needs 20 minutes to raise the building temperature 1 C) and starts the heating accordingly. On this thermostat, optimum start works on the Wake and Return comfort levels. Feature 11 - Rate of Change: Number of minutes to raise the temperature by 1 C Feature 12 - Programming Mode: The thermostat offers 2 programming methods. Weekday/Weekend allows you to program 4 comfort levels for the weekdays and 4 different comfort levels for the weekend. In 7 Day program mode, each day has 4 comfort levels that can be programmed independently. 21 Slimline Series

Adjusting Section Header the Optional Settings To adjust the optional settings, follow these steps. Press and hold the Power button to turn the thermostat OFF... Press and hold the Clock key until the display appears as shown below... Setting Value Feature Number Use the Clock key to cycle through the features... Use the Up/Down keys to change the setting... Press A to confirm settings... Press the Power button once again to turn the thermostat back ON... Model: Slimline-N 22

Section Optional Header Settings - Feature Table FEATURE 01 02 03 04 05 06 07 08 09 10 11 12 DESCRIPTION Temperature Format Switching Differential Frost Mode Frost Protection Temperature Output Delay Communications ID No. Up/Down Temperature Limit Sensor Selection Floor Temperature Limit Optimum Start Rate of Change Program Mode SETTING 00 = C, 01 = F ( C = Default) 01-03 C (01 C = Default) 00 = Enabled, 01 = Disabled (00 = Default) 07-17 C (12 C = Default) 00-15 Minutes (00 = Default) Enter Comms number 01-32 00-10 C (00 = Default) 00 = Built in Sensor 01 = Remote Air Sensor 02 = Floor Sensor Only 03 = Built In & Floor Sensor 04 = Remote Air & Floor Sensor 20-45 C (27 C = Default) 00-03 Hours (00 = Default) Minutes to raise by 1 C 00 = 5/2 Day Programming 01 = 7 Day Programming 23 Slimline Series

Error Section Codes Header E0 = The internal sensor has developed a fault. You should contact your thermostat retailer for assistance. E1 = The remote floor probe has not been connected, has been wired incorrectly or the probe is faulty. E2 = The remote air probe has not been connected, has been wired incorrectly or the probe is faulty. Error Number Model: Slimline-N 24

Re-calibrating Section Headerthe Thermostat If you need to re-calibrate the thermostat, follow these steps. Press and hold the Power button to turn the thermostat OFF... Press and hold BOTH the Power and Down keys together until the temperature appears on the screen... Use the Up/Down keys to configure the new temperature... Press A to confirm settings... Press the Power button once to turn the thermostat back ON... Calibration Temperature Setting Set Icon 25 Slimline Series

Factory Section Reset Header The thermostat has a reset function to restore all settings to their factory defaults. To perform a factory reset, follow these steps. Press and hold the Power button to turn the thermostat OFF... Press and hold the Power and Up keys together until the LCD powers up. All of the icons will be displayed on screen... When the icons have disappeared from the screen, the thermostat has been successfully reset. Press the Power button once to turn the thermostat back ON... All icons displayed simultaneously. Factory reset is complete. Model: Slimline-N 26

Section Wiring Diagram Header - Slimline-N to UH1 Network Remote Air Sensor Slimline-N Floor Sensor 12VDC CH Y B RT2 RT1 - A2 A1 + Connecting Slimline-N to the UH1 The UH1 allows connection of up to eight 12 volt network thermostats. When connecting network thermostats to the UH1 use CAT5-FTP or BELDEN 9538. Connect the screen to Earth at the UH1. FLOOR PROBE (Optional) REMOTE AIR PROBE (Optional) + A1 Y + A1 Y _ A2 B _ A2 B ZONE X UH1 ZONE X 27 Slimline Series

Section Wiring Diagram Header - PRC Voltfree Switching Slimline-N COMMS CABLE Network 12VDC Y B RT2 RT1 - A2 A1 + Recommendations Max Cable Size - 1.5MM Back Box Depth - 35MM Max Load - 3 Amps FLOOR PROBE (Optional) REMOTE AIR PROBE (Optional) 12V _ + A2 B2 L E N POWERED RELAY CARD C NC NO C NC NO For 230V switched live output, link mains L to C 230V SUPPLY IN Volt Free Output Model: Slimline-N 28

Notes 29 Model: Slimline Manual Series REF 29

Notes Model: Slimline-N 30

Notes 31 Model: Slimline Manual Series REF 31

Want More Information? Call our support team on: +44 (0)1254 669090 Or view technical specifications directly on our website: www.heatmiser.com PDF FAQ Twitter: @heatmiseruk Facebook: facebook.com/thermostats Rev.2.0