The new detector from Rafiki

Similar documents
INTELLIGENT FIRE TECHNOLOGY

Sita200plus. 200detectors. Single loop analogue addressable System

SO SMART, YOU WILL CALL IT INTELLIGENT

FIRE ALARM SOLUTIONS THAT FIT YOUR NEEDS

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

Analogue addressable devices

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

System 800 Addressable Fire Detection & Alarm System

Evolution Analogue Addressable Fire System

Emergi-Lite Orbis detectors

Consultant Specification AGILE Wireless Fire Detection System

HART XL High Sensitivity Smoke Detection

MINERVA MZX125 Digital Addressable Fire Detection System

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

HART XL High Sensitivity Smoke Detection

UBS1RF OPTICAL SMOKE ALARM EN 14604:2005/AC:2008 DOP:UBS1RF-001-V1

MINERVA MZX125. Digital Addressable Fire Detection System

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

Analogue Detectors. Series 200 plus

Intellia Sounder Bases and Sounder Beacon Bases

MR300 OPTICAL SMOKE DETECTOR RANGE PRODUCT APPLICATION & DESIGN INFORMATION

Xenex Conventional Fire Detection & Alarm System

S200Plus Triple Infra Red Flame Detector Triple Waveband Infra-Red Flame Detection

TrueAlarm Smoke Detectors

Multi-Point Peripherals

MINERVA S200Plus. Fire Detection. Triple Waveband Infra-Red Flame Detection. Features: Minerva S200PLUS

Series 65 Product Guide MAN 3036

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Multi-Point Peripherals

Cerberus FIT conventional system

Aspirating Smoke Detection

SOUNDER CONTROL MODULE SCM-AS4

Addressable and Conventional Fire Protection

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

Intelligent Security & Fire Ltd

Control Panel Engineering and Commissioning Instructions

INPUT / OUTPUT MINI MODULES

Conventional Detectors

Fire Product Catalog

Quick Selection Guide Fire Systems LSN Periphery

KNX module for smoke alarm devices Dual/VdS and Q-Label (Order no )

Installation, Operating and Maintenance Manual

optical detector multisensor detector heat detector mounting bases product guide

Product Guide MAN7030-2

The complete conventional fire warning system

Addressable Fire Alarm Control Panel

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

Conventional Fire Detection

200 SERIES ADVANCED PHOTO/THERMAL/IR DETECTOR PRODUCT SPECIFICATION

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

DUR 40Ex Intrinsically Safe SMOKE DETECTOR

The supplier and installer of the system should be approved by the local civil defence authority.

Solution F2. Fire Alarm Control Panels one step ahead.

Protec. Protec Algo-Tec TM 6500 Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network. Fire Detection - Addressable

A GUIDE TO FIRE DETECTION AND ALARM SYSTEMS

Opal TM AV Devices. Data Sheet. Benefits

Installation and Operating Instructions

XP95 Sounder VAD Base

Notifier by Honeywell: SMART Detection. SMART Detection. The Ultimate in False Alarm Technology...Make the SMART choice

Battery Powered Smoke/Heat/CO Alarms

LF /2. Fire Alarm Control Panel. Features:

½ CAUTION ½ DANGER. Getting to know the smoke detector. ARGUS Smoke Detector Single. Accessories. Operating instructions. For your safety A B C D E

Control Panel User Guide (TO BE RETAINED BY THE USER)

Addressable Fire Alarm Control System 2100 series

ALK-V PHOTOELECTRIC SMOKE SENSOR

Reflective Optical Beam Smoke Detector User Guide

Polycarbonate External Sounder & Strobe Unit

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

FDMM01S - FDMM02 - FDMM10- FDMM11S FDMM12 - Input / output mini modules

500-IDx Conventional Fire Detectors with Siren!

Intelligent Security & Fire Ltd

Europe s Leading Manufacturer of Fire + Carbon Monoxide Alarms

4 wire conventional alarm system

LaserFOCUS VLF-250 Engineering Specification

PRODUCT GUIDE & INFORMATION. Professional Fire & Carbon Monoxide Solutions

Conventional Smoke Detectors KFAPO

Opal TM AV Devices. Data Sheet. Benefits

Fire-Cryer. Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX. Shaping Alarm Technology

Apollo Intelligent Auto Aligning Beam Detector. User Guide

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

PROPOINT PLUS ASPIRATING SMOKE DETECTION SYSTEM

(68.52) X. June 2000 supersedes February vigilon ADVANCED FIRE DETECTION & ALARM SYSTEMS

OOH740, OOHC740. Cerberus PRO. Automatic fire detectors

SOUNDER BASES AND SOUNDER BEACON BASES

SERIES 65 ENGINEERING PRODUCT GUIDE

General Routing Interface

Motorised Infrared Optical Beam Smoke Detector. User Guide

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

Application, Installation, Operation & Maintenance Manual

Sensors (All Fully Customisable)

TX7100. Intelligent Addressable Optical Smoke Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

APPLICATION NOTE. Document Type. Application Note. Document Title. Date January Version DS0167/Iss 2. ESP Technical Summary

NAM-AS3 LOOP POWERED INPUT MODULE INSTALLATION & TECHNICAL MANUAL

OH110, OP110, HI110 Automatic fire detectors

Protec. Protec Algo-Tec TM 6500 Open Protocol Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network

Control Panel User Guide

ORBIS PRODUCT GUIDE. Optical Detector. Multisensor Detector. Heat Detector. Mounting Bases

Transcription:

The new detector from Rafiki Three smoke detectors Three heat detectors Combined smoke/heat detector Full alarm sounder Strobe End-of-line device/loop isolator

Rafiki s Multipoint ASD detector range have broken new barriers in fire detection and alarm. Not only does the multipoint offer seven modes of fire detection it also offers an optional built-in sounder and a sounder strobe in a single device. The multipoint uses patented advanced optical scatter sensor design along with sophisticated electronic technology to deliver reliable smoke or heat detection, whilst substantially reducing false alarms. The Multipoint ASD retains all the advantages of the original Multipoint detector with a range of additional features to make it a truly market leading design. Stealth Optical Chamber Design The method of optical scatter fire detection is well known. Sensors comprise an optical emitter and a receiver positioned in a sensing chamber. The emitter and receiver are positioned such that there is no line of site between them, although some light from the emitter does reflect on the walls of the chamber and into the receiver; this is known as standing scatter level. When smoke enters the chamber it increases radiation from the emitter and substantially increases the radiation detected by the receiver, a sensor circuit then triggers an alarm. A disadvantage of this design is that dust, grease etc. enters the chamber and settle on the walls causing the scatter level to increase or decrease dependant on the type of contamination. This variation can cause false alarms or can mask the presence of a true alarm condition. Stealth Chamber Rafiki have designed a, patented, optical scatter smoke sensor that alleviates this problem. This has been achieved by creating a secondary chamber that collects the contamination out of site of the emitter and receiver thereby substantially reducing the incidence of false alarms and improving detection reliability. Multi-Criteria Detector The Multipoint detector has set new standards in detector technology, using microprocessor control, offering the installer a full range of detection capabilities with audible and visual warning in one compact device. Specifiers and installers who choose the Multipoint detector, do so secure in the knowledge that the fire detection performance of the detector can be matched to the environment in which it is installed and changed any time during the lifetime of the installation. The mode of detection required can be simply changed by way of a DIL switch in the detector (configurable via commissioning software on addressable systems).

All modes are compliant with European detector type specifications, and are suitable for use in installations compliant with BS5839: Part 1: 2002, Part 6 2004 if used in conjunction with a Twinflex Plus system. The detector offers the following modes of detection: The Twinflex Intelligent conventional detector can be set to any one of the smoke or heat detection modes as well as a Combined Mode (Smoke 2 & Heat 2) where a smoke or heat source can trigger a fire decision. This means the end user is given optimum fire protection, even if the installer is unsure of the use of the particular area where the detector is sited. As part of the Twinflex system all Twinflex products including the Twinflex Multipoint detector feature an End of Line monitoring switch, which negates the need to install End of Line monitoring resistors. The Sita Intelligent addressable detector is able to offer all the choices for detection, or a combination of any listed to give a choice of up to 15 different settings. It is set via a PC when programming the system. The Sita Multipoint also has an in-built loop isolator as well as an input/output facility for local control and switching. The Multipoint Detector also has the unique benefit of an optional full specification integral sounder. A 90dBA output can be achieved. The Twinflex Intelligent two wire detector can be set to 3 different sound patterns, as well as switched off, with 2 sound output levels. The Sita Intelligent addressable detector has 7 different sound patterns and 3 volume settings. REFLECTED OPTICAL VALUE 250 240 230 220 210 200 190 180 170 160 150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0 Fig 1 ALARM 3 2 TRANSIENT REJECTION 1 THERMAL ENHANCEMENT Smoke mode 3 allows for In order to allow more reliable detection in stable operation the difficult environments, as system will increase a small transient or pulse sensitivity when a rise in may be rejected, temperature is seen. This depending on the allows allows a more rapid temperature and duration. detection response in the Ideal for ensuite and effect of a fire condition, steam related areas. whilst maintaining a lower level for normal operative stability. NORMAL OPERATION To overcome the effects of contamination, if the optical reflection rises slowly the device recalibrates by moving the alarm threshold accordingly, ensuring a constant sensitivity at all times Rise < > 35Bit Rise < > 17.5Bit Fire SMOKE 1 Used where ionisation detectors are normally fitted especially when there are high ceilings or a risk of free burning fires (chemical stores etc), or fires that need to be detected extremely quickly. SMOKE 2 Used where optical detectors are normally fitted when there is a risk of a smouldering fire and for escape routes. SMOKE 3 This setting is designed for use in areas that are prone to nuisance alarms. The reduced sensitivity linked with a time delay feature means that a higher concentration of smoke needs to be present for a constant time period, before a fire decision is made (Fig 1). This setting, for example, is ideal for hotel bedrooms with ensuite shower rooms, the end user can change the setting from smoke 2 to smoke 3 if nuisance alarms are becoming a problem whilst still offering optimum protection of a smoke detection setting, especially if this is what has been specified. < Delay> TIME 4 If the reflected optical level equals or exceeds the alarm threshold a smoke alarm signal is sent to the control panel. Fire Clear 5 CONTAMINATION FAULT When the alarm threshold reaches a level of 195bits, the control panel will display a fault and the optical chamber must be replaced. Fault Fault threshold Alarm threshold Optical value Automatic Calibration To ensure the detection capabilities of the Multipoint are never compromised it self-calibrates every 6 hours. It continuously monitors for dust contamination, until, over a period of time, depending on the environment, it reaches a point where the chamber becomes saturated. Before this can develop into a false alarm situation, the panel will indicate that a Multipoint needs attention on both the Twinflex and Sita systems. To make maintenance easy, the Multipoint features a disposable optical chamber. This means the chamber can be simply thrown away, and replaced economically when necessary. HEAT 1 (Rate of Rise) Used where a standard rate of rise detector would normally be used HEAT 2 (Standard Fixed Temperature - 58ºC approx) Used where a standard fixed temperature heat detector would normally be fitted, suitable for kitchens etc HEAT 3 (High Fixed Temperature - 90ºC approx) Used where a high fixed temperature heat detector would normally be fitted, suitable for boiler rooms etc.

Twinflex Specifiers and installers who choose the Multipoint detector do so secure in the knowledge that the fire detection performance of the detector can be matched to the environment in which it is installed and changed at any time during the lifetime of the installation. The mode of detection required can be simply set by configuring the DIL switch in the detector electronics module. All modes are compliant with European detector type specifications, and are suitable for use in installations compliant with BS5839: Part 1: 2002. MODES OF DETECTION SMOKE 1/Highly thermally enhanced optical Used where ionisation detectors are normally fitted, especially when there are high ceilings or a risk of free burning fires SMOKE 2/Thermally enhanced optical Used where optical detectors are normally fitted, when there is a risk of a smouldering fire and for escape routes. SMOKE 3/Thermally enhanced optical with pulse rejection Used where optical detectors are normally used in positions exposed to brief concentrations of water vapour or smoke e.g. from a bathroom, kettle etc. HEAT 1/Rate of rise to 58 C Used where a standard rate of rise detector would normally be used HEAT 2/Low fixed temperature 58 C Used where a standard fixed temperature heat detector would normally be fitted, suitable for kitchens etc HEAT 3/High fixed temperature 90 C Used where a high fixed temperature heat detector would normally be fitted, suitable for boiler rooms, commercial kitchens, etc. SMOKE 2/HEAT 2 A combination mode of SMOKE 2 & HEAT 2 will trigger with either a smoke or heat source. Technical specifications Compatibility: Twinflex 2-wire Operating Temperature: -10 C to 50 C Voltage Range: 18 to 35v DC Operating Current: Quiescent: 65µA Alarm: 20mA Sound high: 16mA Sound low: 8mA With a sounder/strobe Sound high: 18mA Sound low: 10mA Loading: MP: 0SLU (max 32 SLUs per zone) Sounder: 1SLU Sound Outputs: Low: 75dB(A) High: 90dB(A) Sound Tones: 0, 1, 3 + 4 LED Operation: Quiescent: 20s interval EOL: 5s interval Fault: 1.3s interval Alarm: Constant Part Code: No sounder: 204 0003 With sounder: 204 0001 With sounder strobe: 204 0012

67mm Twinflex 107mm max Detector standard 75mm 107mm max If the Multipoint with integral sounder is required, then it too can be set to a choice of 7 different sound patterns and the volume can be set to either: High (90 dba) Low (75 dba) Detector with strobe

Sita Specifiers and installers who choose the Multipoint detector do so secure in the knowledge that the fire detection performance of the detector can be matched to the environment in which it is installed and changed at any time during the lifetime of the installation. With the Sita 200 plus System a high technology approach has been adopted, with a microcomputer in each detector implementing a large degree of distributed intelligence. The system can support 200 Multipoint combined detector/sounders on a single loop. Each one not only provides detection, but also the option of a built in sounder. Integrity of the system is maintained by way of a built-in isolator in each device. Sita system intelligence has been harnessed in such a way that equipment used is very easy to install, commission and maintain. The system has been designed to high specification and quality standards, and is intended to fully comply with the new EN54-2 and EN54-4 standards and EU directives Fast short circuit isolator in every device 15 combinations of smoke & heat detection modes Multi stage alarms - pre alarm feature 7 sound patterns - plus off, 3 different volume settings if using Sita Multipoint with integral sounder Auxiliary digital inputs and outputs are available at any Addressable Multipoint device Automatic continuous self calibration Addressable Multipoint detector is monitored for all failures of sensor chamber - warning is indicated when a smoke detector head requires servicing Maintenance is made easy with the unique disposable optical chamber, designed as a cost effective solution to cleaning and re-calibration All modes are compliant with European detector type specifications, and are suitable for use in installations compliant with BS5839: Part 1: 2002. Technical specifications Compatibility: Sita 200 plus Operating Temperature: -10 C to 50 C Voltage Range: 16 to 48v DC Operating Current: Quiescent: 96µA MP alarm: 4.9mA Sound high: 8mA Sound med: 4.7mA Sound low: 1.71mA With Sounder/Strobe: High: 9.71mA Med: 5.81mA Low: 2.71mA Strobe: 1ALU Loading: MP: 0ALU Sounder low: 0.5 ALU Sounder med: 1.5 ALU Sounder high: 2.5 ALU Sound Outputs: Low: 75dB(A) Med: 85dB(A) High: 92dB(A) Sound Tones: 0, 1, 2, 3, 4, 5, 6 + 7 LED Operation: Quiescent: 20s interval Fault: 5s interval Alarm: 0.3s interval Part Code: with sounder: 205 0001 no sounder: 205 0003 bases: 905 0001(pack of 5 sold separately) Sounder/strobe: 205 0012

Modes of detection 67mm SMOKE 1 Highly thermally enhanced optical Used where ionisation detectors are normally fitted, especially when there are high ceilings or a risk of free burning fires SMOKE 2 Thermally enhanced optical Used where optical detectors are normally fitted, when there is a risk of a smouldering fire and for escape routes. Detector standard 107mm max SMOKE 3 Thermally enhanced optical with pulse rejection Used where optical detectors are normally used in positions exposed to brief concentrations of water vapour or smoke e.g. from a bathroom, kettle etc. Sita HEAT 1 Rate of rise to 58 C Used where a standard rate of rise detector would normally be used HEAT 2 Low fixed temperature 58 C Used where a standard fixed temperature heat detector would normally be fitted, suitable for kitchens etc HEAT 3 High fixed temperature 90 C Used where a high fixed temperature heat detector would normally be fitted, suitable for boiler rooms etc. Combinations Any combination of smoke and heat modes may be selected, and differing alarm responses selected for each mode. If the Multipoint with integral sounder is required, then it too can be set to a choice of 7 different sound patterns 75mm 107mm max Detector with strobe

Sita Twinflex For more information on the Multipoint ASD Detectors contact your supplier Rafiki Protection Limited 31 Springvale Industrial Estate, Cwmbran NP44 5BD United Kingdom t: +44 (0) 1633 865558 f: +44 (0) 1633 866656 e: rafikisales@rafiki.biz w: www.rafiki.biz