NEW GREEN TECHNOLOGY

Similar documents
Carisma Fly Carisma Fly-ECM. Made in. Italy. High Wall Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT

Carisma Fly. Made in. Italy. Wall-mounted Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT.

SABIANA ENVIRONMENTAL COMFORT. Air Conditioning Futura Fan Coil Units ICIM

High wall fan coils Climmy FHW/FHW-ECM. Technical Catalogue

Product is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue

QZHW Fan Coil Unit. Key features. Specifications

NEW. MB control board. communication protocol. for Modbus. Air Conditioning Carisma CRSO High Pressure Fan Coil Units

SkyStar SK. Cassette Fan Coil Unit with Asynchronous Motor

UniTrane Terminals. High Wall Fan Coil: W-Line Ducted Fan Coil: D-Line Blower coil: B-Line. Product Presentation September 2016

The Sabiana. of Fan Coil

DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS

QZB "Standard" comfort fan coil

SkyStar SK-ECM. Cassette Fan Coil Unit with EC Brushless Electronic Motor and Inverter Board

NEW. SkyStar SkyStar ECM. Cassette Fan Coil Units. consumption ECM motors. Low energy. Air Conditioning ENVIRONMENTAL COMFORT

Air Conditioning Carisma CRS High Pressure Fan Coil Units.

consumption ECM motors NEW Low energy Cassette Fan Coil Units YHK ECM YHK

NEW. communication protocol. Control board with Modbus. Air Conditioning SkyStar SkyStar ECM Cassette Fan Coil Units

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM

NEW. Wall Controls. Air Conditioning Ceiling Air Conditioning Elegant. Cert. n 0545

UniTrane Ductable Units D-line and B-Line

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT

Application guide. ARMONIA ARMONIA EC 1,3-11 kw. Chilled water cassette Chilled water cassette - EC motor ARMONIA-AGU-1010-E

Blower-YEFB-020-3R-1maxVel

SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER)

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

FAN COIL UNITS LASER / LOW BODY / CONCEALED

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

Powrmatic PZN / PZN X Hot Water Heater

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

SABIANA ENVIRONMENTAL COMFORT. Air Conditioning Ceiling Air Conditioning Elegant

EHH SERIES DRAW THROUGH FAN COILS CFM

Energy. The Energy ducted units have been designed. Heat Recovery Unit

CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT

BRIZA EC 12 HYBRID. Low Water-Temperature system LOW TEMPERATURE SYSTEM / HEATING AND COOLING

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

Helios. Unit Heater. Thickness 1 mm. Diameter 22 mm. Pitch 2,5 mm. Fin 0,12 mm

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSWALL. Wall mounted fan coil units

SIGMA PRISMA LOW BODY CONCEALED

QFDK "ägir II" chilled water cassette

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

Galletti IWC THE HYDRONIC CASSETTE UNIT PAR EXCELLENCE A guide to choosing Create value to design better

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

Centrifugal air heaters hot water or electrical supply

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams

CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT. Cooling

QTS SELECTION TECHNICAL BOOKLET

KOG LN. Low Noise Chilled Water Cassettes Models 09, 12 & to 6.10kW to 5.10kW. 330 to 920 m3/h

Packaged air cooled liquid chillers for outdoor installation kw. technicalcatalogue T_EGL_1012_GB

ENERGY TOP. Condensing boiler solutions

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

YFCN Fan Coil Unit centrifugal fan

COMFORT APPLICATION HYDRONIC TERMINALS ELEGANCE AND DESIGN FOR YOUR RESIDENTIAL COMFORT

Transformer oil coolers BETA & CETA

OMNIA RADIANT FAN COIL WITH RADIANT HEATING PANEL THE FAN COIL FEATURING 3 HEATING MODES

Application guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort

Conditioning your ambient, maximising your comfort.

FREEDOM 2019.EX CZ - 21/11/18

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

NEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

FAN COIL UNITS. The optimal solution for limited space

BRIZA_038. EC MOTOR Briza Hybrid: High performance technology

termo plus High Efficiency Radiator Novelty in Heating Systems Designed by Engineering Germany

Brise speed speed control 2. BRIC ceiling model 3. BRIW wall model 4. BRBW wall build-in model 5. grille from ABS 6.

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

EMI ENGINEERING SUBMITTAL

KELVIN Clim F497. Kelvin air conditioning

Next MTR kw. technicalcatalogue. Air conditioners for Metrology Labs with upflow air delivery T_NXTMTR_0511_GB

OMNIA FAN COIL FOR RESIDENTIAL APPLICATIONS EXCLUSIVE DESIGN, NUMEROUS VERSIONS. Floor & ceiling installation Applicable with VMF management system

CDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel.

HRV-IP. Ceiling Type Heat Pump Heat Recovery Unit

Heating / Air Conditioning Energy Heat Recovery Units ENVIRONMENTAL COMFORT

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

REKO heat recovery units REKO HEAT RECOVERY UNITS TYPE A TYPE D

Type CODE Speed Heating Cooling

Aerslim Fancoil unit. Technical information manual. Western Airconditioning B.V. Tel. +31 (0)

CONDENSING UNITS AIR COOLED CONDENSER. COOLING ONLY

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

4,5 22,5 kw. technicalcatalogue. Air-conditioned server-racks for direct installation into the room T_CLSEVO_0113_GB

Also available with the new i-life R-Slim inverter and radiant panel version. Perfect comfort. Silent operation. Real energy savings

ART-U 1-4 kw. Design fan coil unit with a minimum depth of 10 cm only and BLDC motor. Fan coil ART-U PLUS. Design-driven innovation NEW

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

Condensing Units CUS 15-60

UCS UCS/M UCS/H UCS900

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

Brise speed speed control 2. BRIC ceiling model 3. BRIW wall model 4. BRBW wall build-in model 5. grille from ABS 6.

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

Energy saving ventilation Air handling units (Catalogue no. 2) Industrial and commercial ventilation. (Catalogue no. 1)

30GT FLOTRONIC AIR-COOLED CHILLERS

in/out connections outer Ø 25 bar (363 psi) 200 kg/h SS '000 (2.12 HP) 300 kg/h CU (661 lb/h) (3.18 HP) 300 kg/h SS (661 lb)

ACCUMULATION OF EUROPEAN CLASS

Your Climate. We're There. TM: MDB B 2140B. Ducted Split Systems. Models: MDB 075B - MDB750B MDB 075B/B - MDB500BR. Air Conditioning REGISTERED

INDEX. Main components 3. General features and description of the components 4

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

Delivering More Clean Air, At a Faster Rate With Less Noise

Transcription:

NEW GREEN TECHNOLOGY - suitable for all heating systems Magnetic Boiler installed in all fan coils - no need for external devices! A c t i v e G r e e n S w e d e n A B

ACTI VE Operation limits This technology can supply all heating systems The boiler installed in all fan coils Lowest water inlet to Magnetic Boiler temperature ----------------- + 5 C Highest water output temperature from Magnetic Boiler ------------- + 85 C Magnetic Boiler Model Magnetic Boiler Position ( s ) calibration Heating boiler ( S ) Material Bronze / Copper Energy Type Of Natural Circulation Electricity supply Magnetic 20V/50/60Hz - 80V.400.V/50Hz.AC Electricity Consumption 0.64 / 0.86 /.08 /. / kwh power supply W 640/ 860/ 080/ 00/ Watt Output power. KW h 4.48 kw / 6.02 kw / 9.72kw/.7kw /h Output power Watt/ h W.4480 / 6200 / 9720 / 700 / Watt / h Current running W. 640 / 2.8. A / 228.574. V w. 860 /.5. A / 245.74.V w.080/ 4.. A/ 26.446.V w.00 / 4..A/ 02.256 V Kelvin From k 278.5 up to k 58.5 Pascal Pa 200 000 / Pa 00 000 Capacity heating celsius +5 C -- + 85 C -.Fahrenheit - F. 4 - F 86 pipe connection Pump Circulation.. /4 / /4 / Inch water / in / Out Pump lift m 5 Minimum water Flow L/min Pressure / Bar 2 / Net dimensions 80. mm / 80. mm / 6. mm Net weight 4.5 / 5.5 / 7.5 / 8 Kg 200.mm / 00.mm / 6.mm (2)

ACTI VE CRC version Operation limits EUROVENT Certification This new technology can supply all heating systems The Magnetic Boiler installed in all fan coils CRC 74 / 84/ 94 Lowest water inlet to Magnetic Boiler temperature ----------------- + 5 C Highest water output temperature from Magnetic Boiler ------------- + 85 C Highest water inlet temperature to Fan Coil... + 80 C Lowest water inlet temperature...+ 5 C For entering water temperatures below + 5 C, Contact( Active) technical department Highest working pressure...000 (0 bars). Note: For CRC model the maximum installation height is 200 mm On heating it must be paid attention to rooms where the floor temperature is particularly low (for example less than + 5 C). In this situation the floor can cool the lower layer of air to a level that can stop the uniform diffusion of the hot air coming from the unit. Magnetic Boiler Water flow limits for row coil () MODEL CRC 74 CRC 84 CRC 94 HEATING Entering air temperature + 20 C Entering water temperature + 50 C Water flow rate as for the cooling conditions MODEL Lowest CRC 74 Speed 2 (E) 200 2000 Highest 4 (E) 00 2000 CRC 84 5 6 (E) 2 (E) 655 4 (E) 00 2250 CRC 94 5 6 (E) 2 (E) 85 020 00 200 75 4 (E) 5 6 (E) 980 20 65 500 m/h 445 Heating (E),55 4,20 4,86 5,55 6,9 6,7 4,0 5,06 6, 7,6 7,84 8,4 5,59 6,22 7,4 8,5 9,8 0,08 Dp Heating (E) 7,7 W 44 Air flow Fan (E) 55 60 75 840 925 80 4, 6,2 8,4,4 2,7 4,5 7,2 8,7, 4,8 7,0 9, 66 79 92 0 47 62 8 05 6 0 78 92 08 4 52 76 54 56 9 45 50 56 58 60 47 50 54 58 62 64 45 47 0 6 4 47 49 5 8 4 45 49 5 55 0,, 6,9 20,5 2,7 54 50 Sound power (E) Lw db(a) 8 42 47 5 Sound pressure (*) Lp db(a) 29 8 42 (E) = Eurovent certified performance. -- = Standard connected speeds. (*) = The sound pressure levels are 9 db(a) lower than the sound power levels and apply to the reverberant field of a 00 m room and a reverberation time of 0.5 sec. ()

ACTI VE EUROVENT Certification Emission of conditioned air Casing Heat exchanger CRC Centrifugal fan Electrostatic filter Magnetic Boiler Pre-filter Magnetic Boiler Ambient air intake Heating emission of row coil CRC version Entering air temperature: 20 C WT: 70/60 C MODEL CRC 74 CRC 84 CRC 94 Speed VI V IV III II I VI V IV III II I VI V IV III II I Qv WT: 60/50 C Qw Dp(c) Qw Dp(c) WT: 50/40 C Qw Dp(c) WT: 50/45 C Qw Dp(c) WT: 45/40 C Qw Dp(c) m /h 925 840 75 60 55 445 200 00 020 85 655 50 500 65 20 980 80 75 0,55 9,76 8,7 7,67 6,72 5,7,25 2,6,6 9,67 8, 6,49 5,74 4,70,9,29 9,82 8,87 907 89 75 660 578 49 40 06 000 82 697 558 54 264 52 97 845 76 28, 24,5 20, 6,0 2,7 9,5 8,5 6,4 4,7 0,6 7,8 5, 25, 22, 8,9 4,0,0 9,2 8,0 7,49 6,7 5,9 5,7 4,9 0, 9,45 8,90 7,40 6,22 4,98 2,0,2 0,24 8,64 7,52 6,85 697 644 577 50 445 78 87 8 765 66 55 428 05 966 88 74 647 589 8,2 5,8,0 0,5 8, 6,2,9 0,6 9,5 6,9 5,,4 6, 4, 2, 9,0 7, 6,0 5,64 5,22 4,68 4,5,62,08 7,0 6,55 6,7 5,4 4,,47 8, 7,77 7,09 5,99 5,22 4,76 485 449 402 57 265 60 56 5 442 72 298 75 668 60 55 449 409 0,0 8,7 7,2 5,8 4,5,4 6,5 5,7 5,2,7 2,8,9 8,7 7,7 6,6 4,9,8, 6,44 5,96 5, 4,7 4,,49 8,09 7,55 7,0 5,90 4,96,97 9,6 8,98 8,8 6,89 6,00 5,46 08 025 97 80 707 600 9 299 22 05 85 68 65 545 407 85 02 99 42,2 6,8 0, 24,4 9, 4, 27,9 24,7 22,2 6,0,8 7,9 7,8,5 28,4 2,0 6,5,9 5,2 4,8 4,,8,4 2,8 6,55 6, 5,75 4,78 4,02,22 7,78 7,26 6,62 5,58 4,86 4,42 900 8 745 659 574 487 27 05 989 822 69 554 8 249 9 960 86 760 29,7 25,9 2, 7,2,5 0, 9,6 7, 5,6, 8, 5,6 26,5 2,5 9,9 4,8,6 9,8 LEGEND WT = Water temperature Speed = Fan speed = Emission Qw = Water flow = Medium speed = Low speed Qv = Air flow Dp(c) = Water pressure drop Tel:0046 (0) 0-74 88 54 WWW.GPT00.COM Mobil:0046 ( 0 ) 70426204 = High speed 446 Älvängen Sweden Euro - 200 TE. 00 ARHL 00 22 F (4) WWW.active.COM

A C T I V E CRR version Dimensions, Weight, Water content Coil connections on the left MV Ø /2" F A WATER OUTLET 58 C 58 00 (min.) 60 50 27 475 225 Ø 5 ext. 7 44 25 00 45 00 A 4 6 8 WATER INLET 60 60 Feet optional extra Dimensions (mm) MODEL 2 4 A C 670 54 770 454 985 669 200 884 PACKAGING Z 720 820 05 250 220 600 Weight (kg) MODEL Z Weight with packaging Weight without packaging 2 4 2 4 4 9 22 2 8 20 Water content (litres) MODEL 2 4 0,4 0,5 0,8, Tel:0046 (0) 0-74 88 54 WWW.GPT00.COM Mobil:0046 ( 0 ) 70426204 446 Älvängen Sweden Euro - 200 TE. 00 ARHL 00 22 F WWW.active.COM ( 5 )

A C T I V E CRR version Construction Outer casing Made from strong synthetic lateral corners and from galvanized and pre-painted frontal steel sheet. The plastic top grid has fixed louvres and is reversible in order to distribute the air in two different directions. Standard colours: Lateral corners and top grid: Pantone Cool Grey C (light grey) Frontal sheet: RAL 900 (white) Other colours on request. Inner casing Made from mm galvanized steel insulated with polyolefin (PO) foam (class M). Filter Polypropylene cellular fabric regenerating filter. The filter frame of galvanized steel is inserted into special plastic sliding guides fastened to the internal structure for easy insertion and removal of the filter. Filter presence is highlighted by a plastic front cover featuring the same colour as the top grid. Fan assembly The tangential fan assembly is composed of two fan shrouds: an external one in PVC and an internal one of holed, shaped steel. The fan has an external diameter of 20mm and is the lenght of the coil. The fins are concave and are positioned in a spiral shape along the whole lenght of the fan. Electric motor The motor is wired for single phase and has three speeds, with capacitor. The motor is fitted on sealed for life bearings and is secured on anti-vibration and self-lubricating mountings. Internal thermal protection with automatic reset, protection IP 20, class B. Coil It is manufactured from drawn copper tube and the aluminium fins are mechanically bonded onto the tube by an expansion process. The coil has two /2inch BSP internal connections and /8 inch BSP air vent and drain. The coil is not suitable for use in corrosive atmosphere or in environments where aluminium may be subject to corrosion. The connections are on the left side facing the unit. On request we can deliver the unit with the connections on the right end side: this must be specified on the order as this operation can not be carried out on site during installation. Condensate collection tray Made from plastic (ABS UL94 HB) and fitted on the inner casing. The outside diameter of the condensate discharge pipe is 5mm. Accessories and Controls See pages 2-50. Tel:0046 (0) 0-74 88 54 WWW.GPT00.COM Mobil:0046 ( 0 ) 70426204 446 Älvängen Sweden Euro - 200 TE. 00 ARHL 00 22 F ( 6 ) WWW.active.COM

A C T I V E CRYSTALL (for CRC units) Introduction The CRYSTALL ACTIVE electrostatic filter matches the need for better e air conditioning with the concepts of space and design. With this filter the various stages of air treatment are combined in one appliance. Thanks to this new patented filter (efficiency compliant with new Standard UNI 254), air pollutants such as cigarette smoke, dust (PM0, PM2.5), pollen and most biological organisms are eliminated. In addition, as fresh air is not being introduced to obtain the best climatic conditions, there are consequential energy savings. Emission of conditioned air Casing Operating principle of the CRYSTALL ACTIVE electronic filter Heat exchanger CRC Centrifugal fan Electrostatic filter Pre-filter Ambient air intake When polluted air goes through the mechanical pre-filter (ase ) the particles 50 μm are eliminated (powder, insects, etc.). Then the smallest particles (50 0.0 μm) are exposed to an intensive ionic field and are polarized (ase 2). The charged particles passing through the second filter section, are pushed back by the anode and attracted to the collection surfaces by a strong, induced magnetic field (ase ). The air which leaves the unit is free from polluting particles. Air without particles < μm Electrostatic filter Air without particles 50 μm Pre-filter OUTLET OF CLEAN AIR PHASE PHASE 2 PHASE INLET OF POLLUTED AIR Collection surface Inducted anode Polarized electrode Ionic field Elimination of the biggest particles Tel:0046 (0) 0-74 88 54 WWW.GPT00.COM Mobil:0046 ( 0 ) 70426204 446 Älvängen Sweden Euro - 200 TE. 00 ARHL 00 22 F ( 7 ) WWW.active.COM

Green Sweden Active This new technology can supply all heating systems The Magnetic Boiler installed in all fan coils CVP T / 4 Lowest water inlet to Magnetic Boiler temperature -- + 5 C Highest water output temperature from Magnetic Boiler -- + 70 C EUROVENT Certification Magnetic Boiler Model Speed Air flow Heating (E) m/h P Heating (E) fan (E) Sound power (E) Sound pressure (*) W Lw db(a) Lp db(a) (E) 280 2,0 0,5 6 5 26 2 (E) 75 2,90 5,4 2 40 480,57 2,2 26 45 6 4 4 (E) MaX 545,99 25,4 29 48 9 5 6 70 4,90 4,7 8 55 46 780 5,5 7,9 46 57 48 00 2,44,7 7 6 27 2 (E) 440, 9, 2 4 4 500,69 22,5 27 46 7 4 (E) 60 4,0 28,9 2 5 42 5 675 4,6 2, 5 54 45 6 (E) MaX 790 5,20 8,5 48 57 48 WEIghT (kg) Model without valve with valve Tel:0046 (0) 0-74 88 54 WWW.GPT00.COM Mobil:0046 ( 0 ) 70426204 2 Weight packed unit 2 2 6 7 4 6 7 0 446 Älvängen Sweden Weight unpacked unit 2 0 4 4 4 Euro - 200 TE. 00 ARHL 00 22 F (8) WWW.active.COM

A C T I V E Versions and Main components VERSIONS All versions are available without valves, with 2 way valve or with way valve fitted in the unit. There are four sizes available in the following versions: CVP without infra-red remote control and without valve CVP-2V without infra-red remote control with fitted 2 way valve CVP-V without infra-red remote control with fitted way valve ----------------------------------------------------------------------------------- CVP-T with infra-red remote control and without valve CVP-T-2V with infra-red remote control with fitted 2 way valve CVP-T-V with infra-red remote control with fitted way valve ------------------------------------------------------------------------------- CVP-MB with MB electronic board and without valve CVP-MB-2V with MB electronic board with fitted 2 way valve CVP-MB-V with MB electronic board with fitted way valve CONSTRuCTIONal features Of ThE MaIN COMPONENTS Casing Made of auto-extinguishing ABS UL94 HB plastic with high specifications and great resistance to aging. air filter Washable-regenerable synthetic filter, readily accessible. fan assembly Made of plastic tangential fan. Electric motor The motor is for single phase supply and has six speeds, three of which are connected, with capacitor. The motor is fitted on sealed for life bearings and is secured on anti-vibration and self-lubricating mountings. Internal thermal protection with automatic reset, protection IP 20, class B. The speeds connected in the factory are indicated by, and in the following tables. heat exchange coil It is manufactured from drawn copper tube and the aluminium fins are mechanically bonded onto the tube by an expansion process. The coil has two /2 inch BSP internal connections and /8 inch BSP air vent and drain. The heat exchanger is not suitable for use in corrosive atmosphere or in environments where aluminium may be subject to corrosion. The connections are on the left side facing the unit. Condensate Collection Tray Made from polypropylene; the outside diameter of the condensate discharge pipe is 6mm. Installation template A cardboard installation template is supplied with every unit to help the mounting on the wall. Tel:0046 (0) 0-74 88 54 WWW.GPT00.COM Mobil:0046 ( 0 ) 70426204 446 Älvängen Sweden Euro - 200 TE. 00 ARHL 00 22 F ( 9 ) WWW.active.COM

ACTI VE CVP-T version Magnetic Boiler Stand alone units: the infra-red remote control can control one unit only Controls and units RT0 Infra-red remote control The electronic board, mounted as per standard on the CVP-T, is set to carry out different functions and adjustment modes, in order to meet the installation requirements. These modes are selected by setting the configuration dip switches on the board. fan on/off thermostatic control. Valve on/off thermostatic control and continuous ventilation. Valve and simultaneous ventilation on/off thermostatic control. fan operation control depending on the coil temperature (cut-out T probe fitted), which can be activated only in heating mode or heating and cooling mode. Automatic switch of the operating mode by means of T2 water probe (optional). Seasonal switch by means of remote contact. on/off of the fan coil by means of the remote contact (window or clock contact). Electric heater control By activating the cut-out T probe function, the fan is stopped in winter when the coil temperature is lower than 2 C and started when the temperature reaches 6 C. In summer mode, the fan stops when the temperature inside the coil exceeds 22 C and starts when it drops below 8 C. The infra-red remote control allows setting by a remote position the fan coil operation parameters. The RT0 infra-red remote control features the following functions: Switch the appliance on and off. Temperature set. (0 )

A C T I V E WORkINg CONDITIONS Working conditions and air throw Max. entering water temperature... + 70 C MIn. entering water temperature... + 6 C for entering water temperatures below + 5 C, contact Active technical department Max. rated pressure...000 (0 bars) Installation height (m) Model 4 Minimum 2 Maximum Motor electrical data (max. absorption) 20/ 50Hz Model 2 4 W 0 2 46 48 A 0,6 0,6 0,2 0,2 Tel:0046 (0) 0-74 88 54 WWW.GPT00.COM Mobil:0046 ( 0 ) 70426204 446 Älvängen Sweden Euro - 200 TE. 00 ARHL 00 22 F WWW.active.COM ( )

4 99 4 A C T I V E Emission of conditioned air Casing CoIL CoNNECTIoNS on THE LEfT A Heat exchanger CRC Centrifugal fan 22 22 Electrostatic filter Pre-filter 22 Ambient air intake A MOuNTINg DIMENSIONS 6 B 92 20 58 28 276 C 92 64 58 OUT 2 97 97 2 99 ø6 64 IN 8 ø6 ø6 4 7 8 22 ( 2 )

A C T I V E 270 95 Z DIMENSIONS (mm) Model 2 4 A 880 880 85 85 B 678 678 98 98 C 69 69 996 996 Z 950 950 255 255 WEIghT (kg) Weight packed unit Weight unpacked unit Model 2 4 2 4 without valve 2 2 6 6 0 0 with valve 7 7 4 4 WaTER CONTENT (l) Model 2 4 litres 0,85 0,85,28,28 Tel:0046 (0) 0-74 88 54 WWW.GPT00.COM Mobil:0046 ( 0 ) 70426204 446 Älvängen Sweden Euro - 200 TE. 00 ARHL 00 22 F ( )

ACTI VE heating emission Entering air temperature: +20 C WT: 70/60 C Model CVP CVP 2 CVP CVP 4 Speed VI V IV III II I VI V IV III II I VI V IV III II I VI V IV III II I WT: 60/50 C WT: 50/40 C WT: 50/45 C WT: 45/40 C Qv m/h Qw dp(c) Qw dp(c) Qw dp(c) Qw dp(c) Qw dp(c) 500 470 75 40 270 205 545 480 400 65 05 250 780 70 545 480 75 280 790 675 60 500 440 00 5,46 5,22 4,40 4,07,9 2,7 5,98 5,44 4,74 4,4,8,26 8,77 8,4 6,67 6,02 4,88,87 8,85 7,86 7,29 6,2 5,62 4,0 470 449 78 50 292 2 54 468 408 80 29 280 754 77 57 58 420 2 76 676 627 55 48 52 9,9 8,4,5,8 8,5 5,6 2,5 9,8 5,4,6 0,5 7,9 46,2 42, 28,2 2,5 6, 0,6 47, 8,0,2 25,0 20,8,8 4,22 4,0,40,6 2,6 2, 4,6 4,20,66,42 2,97 2,5 6,80 6,47 5,8 4,69,8,02 6,86 6,0 5,66 4,84 4,8,20 6 46 29 27 226 8 97 6 5 294 255 28 585 556 446 40 27 260 590 525 487 47 76 275 2,9,9 8,8 7,7 5,5,7 5,2 2,9 0,0 8,9 6,9 5,2 0, 27,7 8,6 5,5 0,7 7,0 0,8 24,9 2,8 6,4,7 7,8 2,96 2,8 2,40 2,2,86,50,24 2,95 2,58 2,4 2,0,80 4,8 4,59,69,4 2,72 2,7 4,86 4, 4,02,45,2 2,0 254 244 206 9 60 29 278 254 222 207 80 55 44 94 7 288 24 87 48 7 46 297 269 98 7, 6,5 4,9 4,2, 2, 8, 7, 5,5 4,9,8 2,9 6,9 5,4 0,4 8,7 6,0 4,0 7,2,9 2,2 9, 7,7 4,5,2,7 2,67 2,48 2,06,64,64, 2,88 2,68 2,2,98 5, 5,07 4,05,66 2,96 2,4 5,8 4,78 4,42,78,4 2,48 286 27 20 2 77 4 284 248 2 200 70 458 46 48 5 254 20 46 4 80 25 29 2 0, 27,7 20,4 7,7 2,7 8,5 5,5 29,9 2, 20,5 5,8,8 69,9 6,9 42,5 5,5 24,2 5,9 7, 57,4 50,0 7,7, 7,7 2,7 2,58 2,8 2,02,68,4 2,96 2,69 2,5 2,9,90,62 4,5 4,4, 2,99 2,4,92 4,9,90,62,09 2,79 2,04 2 222 87 74 45 6 255 22 202 88 6 9 74 56 285 257 209 65 78 6 266 240 75 2,2 9,5 4, 2,5 9,0 6,0 24,9 2,0 6,4 4,4,2 8,4 49,4 45,2 0,2 25,2 7,,4 50, 40,6 5,5 26,7 22,2 2,6 legend WT = Water temperature = Emission Qw = Water flow dp(c) = Water side pressure drop Tel:0046 (0) 0-74 88 54 WWW.GPT00.COM Mobil:0046 ( 0 ) 70426204 Speed Med Qv = fan speed = High speed = Medium speed = Low speed = Air flow 446 Älvängen Sweden Euro - 200 TE. 00 ( 4 ) ARHL 00 22 F

Green Sweden Active CRC 94 CRC 84 CRC 74 This new Technology can supply all Heating systems The Magnetic Boiler installed in all fan coils New Unique model is very easy Install without outdoor unit Also available as floor Heaters Sabiana take part to the Eurovent program of fan coil performance certification. The official figures are published in the web site www.eurovent-certification.com and in theweb site www.active.com - www.gpt00.com The tested performances are: Heating emission (2 pipe units) at the following conditions: - Entering water temperature +50 C - Entering air temperature +20 C - Water flow rate as for the Fan absorption Heating emission (4 pipe units) at the following conditions: - Water temperature +70 C E.W.T. - Entering air temperature +20 C Water pressure drop +60 C L.W.T. Sound power ( 6 )