MODEL: ACWD CEILING CONCEALED Chilled Water Fan Coils Unit

Similar documents
LOW STATIC HYDRONIC DUCTED UNIT

Ceiling Concealed High Volume Chilled Water Fan Coil Unit (50/60Hz)

Fan Coil Unit 1. BOSCH Climate Fan Coil Unit

EHH SERIES DRAW THROUGH FAN COILS CFM

MHW Air Handling Unit (50/60Hz)

Catalog C: McQuay Horizontal Concealed Fan Coil Unit

ED-FUW-2014 (50 Hz/60 Hz) Catalogue/Engineering Data. Large-Sized Chilled Water Fan Coil Unit (50/60 Hz) FUW040A DAIKIN INDUSTRIES, LTD.

technical data Fan coil unit FWB small duct unit

YAH SERIES FAN COIL UNITS

Wall Mounted Split Systems

Models: ACC 75D/DR ACC 100D/DR. ACC - D (Draft) Ceiling Concealed Split Systems

Product Specifications. Vertical Floor Consoles By First Co.

Product Catalog. DCHC Horizontal Concealed Chilled Water Fan Coil with DCBL Motor Airflow: 180~2380 m 3 /h

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

Your Climate. We're There. TM: MDB B 2140B. Ducted Split Systems. Models: MDB 075B - MDB750B MDB 075B/B - MDB500BR. Air Conditioning REGISTERED

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

[U] Serie MHB / MHA Manual de Ingeniería

On the cover Integrated professional services designed for your unique business need.

Content. Part 1 General Information Part 2 Indoor Units Part 3 Outdoor Units Part 4 Installation Part 5 Control...

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

Highly Efficient,Powerful Heating and Cooling.

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

Duct Type Fan Coil Unit. Air flow: 680~4590m 3 /h Cooling capacity: 3.7~22.6kW

SeasonMaker ThinLine Fan-coil Units

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

SeasonMaker ThinLine Fan-coil Units

SKYPAK II, 3 Ton Series, gives you a

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

VRV+AHU System DAIKIN NEW STANDARD SERIES UNIT MODEL AHUR-CA/SA

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

Advance Release September 2009

SKYPAK II, 3 Ton Series, gives you a

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

Large Capacity Fan Coil Units Catalog Belt-Drive and Direct-Drive Cabinet and Hideaway Models

Launching of new SET-FREE Outdoor Units - RAS-FSXN1E Series (8-54HP)-

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT

42CW/CH. Fan Coil Unit (High Static Pressure) 42CW/CH. Welcome to Carrier Website w w w. c a r r i e r. c o m. c n

SECTION FAN COIL UNITS

Evaporadoras Hidrónicas

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

PACKAGE AIR CONDITIONER

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons

VertiCool Aurora Engineering Guide

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH

1. MODELS LIST NOMENCLATURE FEATURES PRODUCT DATA FAN CHARACTERISTICS CLEARANCE DATA...

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

HiLine Vertical Stacking Fan Coils. Type FHSS and FHSK. Catalog

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems

Part 1 General Information... 1 Part 2 Indoor Units... 7 Part 3 Outdoor Units Part 4 Installation Part 5 Control...

DAZZLE TM series Cassette Type Fan Coil Unit. FC-NHDU4 Cassette Type Fan Coil Unit 340~2380 m 3 /h

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

Large Capacity Fan Coil Units Belt and Direct Drive Cabinet and Hideaway

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

Cooling/Heat Pump Convertible Air Handlers

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

VERTICAL FAN COIL UNITS

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

Chilled Water Fan Coil Unit. Model:HFCA Size 03-14

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

technical guide Water-Cooled Self-Contained Units

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

PAJ3. Product Specifications

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL

Concealed Ducted Split Series R-407C MBH

Horizontal Water Source Heat Pumps And Cooling Only Unit

SKYPAK II Heating & Cooling Self Contained Packages

CWA4 Chilled & Hot Water Fan Coil

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42

Cooling/Heat Pump Convertible Air Handlers

FAN COIL UNITS. The optimal solution for limited space

Amendment Sheet. Nomenclature M 5 AC V 100 C R - F X AA. Code : M5ACV Date : Superceded : M5ACV

EEDEN technical data. Fan coil units FWV-FWL-FWM FWD FWB FWC FWF FWT

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ)

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM

DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C

2TEH3F18A1000A 2TEH3F24A1000A 2TEH3F30A1000A 2TEH3F36A1000A 2TEH3F42A1000A 2TEH3F48A1000A 2TEH3F60A1000A 1½

TVR 5G GUIDE SPECS. TVR 5G GUIDE SPECS - JUL.2014 Page 1

SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER)

Compact design & easy maintenance

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Cooling/Heat Pump Convertible Air Handlers

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers

UniTrane Ductable Units D-line and B-Line

Modular Air Cooled Scroll Chillers

PAR5. Product Specifications

Transcription:

MODEL: ACW200D ACW300D ACW400D ACW500D ACW600D ACW800D ACW900D ACW1000D ACW1200D ACW1400D ACWD-2006 ACWD_2006_Cover.indd 1 CEILING CONCEALED Chilled Water Fan Coils Unit 2006-5-25 17:24:07

Contents Main Features... 2 Nomenclature... 3 Parts Description... 3 Specifications... 4 Performance Data... 5 Air Flow... 6 Operating Limits... 7 Water Pressure Drop Curves... 7 Sound Pressure Level... 8 Wiring Diagrams... 9 Outlines and Dimensions... 10 Guide Specifications... 11 Note: Installation and maintenance are to be performed only by qualified personnel who are familiar with local codes and regulations, and experienced with this type of equipment. Caution: Sharp edges and coil surfaces are a potential injury hazard. Avoid contact with them. Warning: Moving machinery and electrical power hazard may cause severe personal injury or death. Disconnect and lock off power before servicing equipment. ACSON is a registered trademark of ACSON International. All rights reserved throughout the world. 2006 ACSON International. Bulletin illustrations cover the general appearance of ACSON International products at the time of publication. We reserve the right to change design and construction specifications at any time without notice. ACWD_2006.indd 1 2006-5-25 17:24:41

Main Features General The new ACW-D FCUs are specifically designed to satisfy high cooling capacity application requirement. They represent one of the most cost effective solutions to provide a comfortable environment for both commercial and residential applications. Their quiet operation, compact dimensions and particularly low height, make units ideal for ceiling concealed installation even in buildings with narrow ceiling spaces. Units are standard supplied with soundproofed suction plenum and air filter. Centrifugal fans, with forward-curved blades, are statically and dynamically balanced and driven by single-phase motors with three speeds.they feature elegant design, advanced structure, high efficiency, low noise, convenient installation and low maintenance. They are widely used in houses, shopping malls, hospitals and office etc. Higher Cooling Capacity in High Delta T Application These units are particularly suitable for high External Static Pressure and high Delta T(chilled water temperature difference) applications. They can delivery more cooling capacity in high Delta T conditions with the specially designed fans & motors, coils and excellent combination of them. Low Chilled Water Pressure Drop In order to meet even the most demanding customer requirements, the new FCUs adopt the most reasonable and optimization water circuit design and utilize the national level thermal test room to guarantee both the perfect performance and a low chilled water pressure drop. Extra High Air Flow Volume at High ESP These units can supply more air flow at high ESP. 10 models of ACW-D cover an air flow range from 340 to 2380CMH at medium speed with ESP of 75Pa in wet coil condition. Air Filter All units can provide up to one-inch thick washable filters. Filters are held by a removable metal strip and can be easily pulled out from the bottom for cleaning or replacement. High Efficiency Heat Exchanger A boundary layer film of air adhering to the fin surface will insulate the fin surface and severely reduces the heat exchange efficiency. ACSON slit fin design eliminates this boundary layer of air and creates continuous turbulence for best heat exchange efficiency. Flexibility Units are available with left or right hand water connections, which can be easily switched in the field by changing the positions of the fan-motor assembly and the supply air flange assembly if required. Compact Design The low height design makes this fan coil unit series ideally suited for the tight ceiling concealed installation Low Noise Design Enlarged fan wheels design allows lower fan RPM selection for the same external static pressure and airflow requirement. Thereby noise level is significantly reduced. 2 ACWD_2006.indd 2 2006-5-25 17:24:42

Nomenclature ACW 200 D- 8 R X F-A A F1 - E Export 1-100mm Extended Drain Pan 2-200mm Extended Drain Pan Omitted for Standard Drain Pan Description of Products: A-Standard Drain Pan F-Extended Drain Pan G-Extended Drain pan+2way Valve H-Extended Drain Pan+3Way Valve I-Standard Drain Pan+2Way Valve J-Standard Drain Pan+3Way Valve K-Standard Drain Pan+Controller L-Extended Drain Pan+Controller M-Extended Drain Pan+2 Way Valve+Controller N-Extended Drain Pan+3 Way Valve+Controller O-Standard Drain Pan+2 Way Valve+Controller P-Standard Drain Pan+3 Way Valve+Controller Material of Drain Pan A-Standard Material S-Stainless Steel Power Supply: A-220V/1PH/50Hz With Filter Back Rerurn Air Plenum With Bottom Removal Filter Pipe Connection: R-Right Hand L-Left Hand(Facing Air Flow) 75Pa External Static Pressure Design Series: D-4 Rows and 2 Pipes Nominal Air Flow(CFM) ACSON Horizontal Ceiling concealed Fan Coil Unit Parts Description MOTOR PLENUM FILTER RIGHT SIDE PLATE FAN LEFT SIDE PLATE TOP PLATE DRAIN GUIDE PLATE COIL DRAIN PAN WATER RETURN CONNECTION WATER SUPPLY CONNECTION 3 ACWD_2006.indd 3 2006-5-25 17:24:44

Specifications Model 200D 300D 400D 500D 600D 800D 900D 1000D 1200D 1400D Nominal Air Flow Cooling Capacity High m 3 /h 332 606 757 894 1154 1446 1622 2115 2455 2748 Medium m 3 /h 311 527 709 859 1120 1408 1538 1980 2217 2576 Low m 3 /h 237 331 501 616 770 1096 1201 1465 1569 1870 Total W 2044 3350 4402 5003 6300 8087 9022 10808 11939 13523 Sensible W 1224 2150 2897 3450 4502 5468 6428 7710 8898 10084 Water Flow m 3 /h 0.223 0.341 0.439 0.499 0.632 0.803 0.889 1.067 1.223 1.368 Type Centrifugal fan(forward-curved galvanized steel fan wheels) Fan Number of Fans 1 2 2 2 2 3 3 4 3 3 Coil Fan Housing Type Testing Pressure Type Galvanized Steel Seamless copper tube mechanically bonded to configurated aluminum fin Pressure test:3.3mpa for 1 minute; Leakage test:1.6mpa for 5 minutes Split-capacitor motor with ball bearing Motor Number of Motors 1 1 1 1 1 2 2 2 2 2 Rated Voltage 220V-240V Rated Frequency Insulation Class 50Hz Class B Rated Power Input W 74 98 107 123 167 268 275 304 501 555 Sound Pressure Level db(a) 42.9 43.1 45.9 46.2 47.9 50.0 48.8 49.1 53.3 53.0 Pipe Connection Rc3/4 Drain Pipe R3/4 Length mm 714 934 1014 1114 1214 1464 1564 1664 1464 1664 Dimension Width mm 534 534 534 534 534 534 534 534 599 599 Height mm 251 251 251 251 251 251 251 251 295 295 Packing Dimension Length mm 737 957 1037 1137 1237 1487 1587 1687 1487 1687 Width mm 553 553 553 553 553 553 553 553 618 618 Height mm 276 276 276 276 276 276 276 276 321 321 Net Weight kg 21 25 29 31 33 44 46 49 53 57 Gross weight kg 23 28 32 34 37 48 51 54 58 63 Operating Weight kg 22 26 31 33 35 46 49 52 56 61 Notes: 1. Nominal air flow is in dry coil conditions with ESP of 75Pa, For air flow in wet coil condition please refer to the correction factors. 2. The performance data are based on the following conditions: On coil conditions of 27 C(DB) and 19.5 C(WB); Entering and leaving chilled water temperature of 5.5 C & 14.5 C; at medium speed with ESP of 75Pa; Power supply 220V~/50Hz 3. All the dimensions are for the units with standard drain pan. To get dimensions for units with extended drain pan, please increase the above length values accordingly. 4 ACWD_2006.indd 4 2006-5-25 17:24:44

Performance Data Cooling Capacity ( The table below is an example) Entering air Water Cooling Capacity Water Pressure ESP Water flow Model Temperature( C) Temperature( C) (kw) Drop (Pa) DB WB In Out Total Sensible m3/h kpa ACW200D 75 24.0 17.9 5.5 14.5 1.563 1.047 0.167 3.5 ACW300D 75 24.0 17.9 5.5 14.5 2.664 1.809 0.270 8.0 ACW400D 75 24.0 17.9 5.5 14.5 3.435 2.373 0.344 15.8 ACW500D 75 24.0 17.9 5.5 14.5 3.872 2.828 0.389 7.2 ACW600D 75 24.0 17.9 5.5 14.5 4.842 3.659 0.482 11.4 ACW800D 75 24.0 17.9 5.5 14.5 6.200 4.614 0.618 10.0 ACW900D 75 24.0 17.9 5.5 14.5 6.934 5.236 0.685 12.7 ACW1000D 75 24.0 17.9 5.5 14.5 8.287 6.183 0.825 21.0 ACW1200D 75 24.0 17.9 5.5 14.5 8.820 7.090 0.899 12.9 ACW1400D 75 24.0 17.9 5.5 14.5 10.036 8.091 1.031 18.4 Entering air Water Cooling Capacity Water Pressure ESP Water flow Model Temperature( C) Temperature( C) (kw) Drop (Pa) DB WB In Out Total Sensible m3/h kpa ACW200D 75 27.0 19.5 5.5 14.5 2.044 1.224 0.223 5.7 ACW300D 75 27.0 19.5 5.5 14.5 3.350 2.150 0.341 12.0 ACW400D 75 27.0 19.5 5.5 14.5 4.402 2.897 0.439 24.6 ACW500D 75 27.0 19.5 5.5 14.5 5.003 3.450 0.499 11.1 ACW600D 75 27.0 19.5 5.5 14.5 6.300 4.502 0.632 18.2 ACW800D 75 27.0 19.5 5.5 14.5 8.087 5.648 0.803 15.8 ACW900D 75 27.0 19.5 5.5 14.5 9.022 6.428 0.889 19.9 ACW1000D 75 27.0 19.5 5.5 14.5 10.808 7.710 1.067 29.0 ACW1200D 75 27.0 19.5 5.5 14.5 11.939 8.898 1.223 22.2 ACW1400D 75 27.0 19.5 5.5 14.5 13.523 10.084 1.368 30.3 Heating Capacity ( The table below is an example) Entering air Water Water Pressure ESP Heating Capacity Water flow Model Temperature( C) Temperature( C) Drop (Pa) DB In kw m3/h kpa ACW200D 75 21.0 60.0 3.654 0.223 5.0 ACW300D 75 21.0 60.0 5.788 0.341 11.0 ACW400D 75 21.0 60.0 6.896 0.439 19.7 ACW500D 75 21.0 60.0 8.327 0.499 8.9 ACW600D 75 21.0 60.0 10.073 0.632 15.0 ACW800D 75 21.0 60.0 13.870 0.803 12.5 ACW900D 75 21.0 60.0 15.220 0.889 16.0 ACW1000D 75 21.0 60.0 18.920 1.067 21.5 ACW1200D 75 21.0 60.0 19.870 1.223 18.4 ACW1400D 75 21.0 60.0 22.810 1.368 25.2 Notes: 1. Cooling capacity and heating capaity are given with ESP of 75Pa at medium speed. 2. Cooling capacity is based on 5.5 C entering water temperature and 14.5 C leaving water temperature. On coil conditions are shown in the tables 3. Heating capacity is based on 21 C entering air temperature(db) and 60 C entering water temperature with the same amount of water flow volume as cooling 5 ACWD_2006.indd 5 2006-5-25 17:24:45

Air Flow Air Flow (m 3 /h) at ESP (Pa) Model Fan Speed 20 30 40 50 60 70 75 80 90 100 H 555 527 501 466 428 354 332 322 285 245 200D M 519 468 441 399 363 323 311 297 259 211 L 406 380 347 307 282 248 237 211 192 177 H 868 822 777 732 679 624 606 562 505 408 300D M 807 762 720 670 618 565 527 511 448 350 L 601 549 515 446 403 359 331 310 259 213 H 1088 1026 969 920 844 778 757 711 649 579 400D M 1009 942 895 848 791 735 709 670 602 526 L 673 645 617 587 565 484 501 449 397 349 H 1230 1159 1105 1046 985 919 894 837 763 659 500D M 1201 1149 1083 1009 949 892 859 821 742 655 L 842 806 766 722 675 632 616 570 508 424 H 1551 1501 1439 1345 1273 1213 1154 1142 1061 945 600D M 1448 1401 1323 1263 1208 1145 1120 1080 1000 895 L 848 846 841 827 809 782 770 742 692 623 H 1959 1890 1813 1656 1554 1453 1446 1329 1248 1183 800D M 1947 1867 1783 1651 1536 1420 1408 1347 1241 1120 L 1496 1413 1365 1281 1233 1143 1096 1088 1002 892 H 2197 2113 2027 1920 1795 1683 1622 1560 1455 1325 900D M 2078 1994 1902 1814 1685 1586 1538 1477 1370 1247 L 1525 1474 1423 1375 1311 1241 1201 1169 1048 940 H 2663 2594 2502 2400 2304 2189 2115 2055 1913 1741 1000D M 2536 2466 2377 2283 2193 2031 1980 1915 1802 1661 L 1655 1644 1636 1609 1570 1498 1465 1435 1352 1245 H 2784 2715 2656 2605 2545 2475 2455 2422 2358 2267 1200D M 2421 2394 2365 2322 2283 2235 2217 2196 2146 2081 L 1636 1632 1622 1615 1592 1580 1569 1536 1518 1493 H 3144 3067 3016 2939 2876 2812 2748 2735 2639 2556 1400D M 2830 2794 2758 2709 2662 2605 2576 2555 2489 2419 L 1977 1962 1948 1927 1904 1876 1870 1834 1808 1766 Notes: 1. Air flow is in dry coil conditions. 2. Correction factors for air flow in wet coil conditions: Model 200D 300D 400D 500D 600D 800D 900D 1000D 1200D 1400D Factor 0.93 0.93 0.88 0.93 0.89 0.95 0.94 0.85 0.95 0.93 6 ACWD_2006.indd 6 2006-5-25 17:24:46

Operating Limits OPERATING LIMITS Water Circuit Maximum water-side pressure Minimum entering water temperature Maximum entering water temperature 1.6 Mpa 3 C (cooling) 70 C (heating) ACWD Room air Minimum temperature Maximum temperature Power supply Nominal single-phase voltage Operating voltage limits 16 C (cooling), 10 C (heating) 36 C (cooling), 30 C (heating) 220-240V ~/50Hz ± 10% Volt / ±2 Hz Water Pressure Drop Curves 60 Water Pressure Drop Curves 400D 300D 600D 000D 900D 1400D Water Pressure Drop (kpa) 50 40 30 20 0 200D 500D 800D 200D 0 0. 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0..2.3 1.4.5 1.6.7 1.8.9 2.0 Water Flow (m 3 /h) Note: The pressure drop is for the coil only and excludes water connections and valves. 7 ACWD_2006.indd 7 2006-5-25 17:24:47

Sound Pressure Level Unit ESP 50Pa 75Pa Speed 1/1 Octave Sound pressure level(dba, ref 20μPa) Overall 1/1 Octave Sound pressure level(dba, ref 20μPa) Overall 63 125 250 500 1k 2k 4k 8k db(a) 63 125 250 500 1k 2k 4k 8k db(a) High 18 27 37 39 39 33 24 15 43.4 22 28 37 39 38 33 26 17 43.5 200D Medium 18 27 35 37 38 32 22 14 42.3 19 30 37 38 38 32 25 16 42.9 Low 16 24 32 35 34 28 17 12 38.9 16 24 34 35 34 27 19 12 39.6 High 16 29 36 38 38 34 24 15 43.3 18 30 36 38 39 37 33 24 44.1 300D Medium 16 27 35 37 37 33 23 15 42.1 17 29 35 37 38 36 31 22 43.1 Low 15 25 32 34 33 29 19 13 38.7 16 28 33 35 36 33 26 17 40.8 High 19 31 40 42 41 38 28 18 46.5 19 32 39 41 41 38 32 25 46.2 400D Medium 18 31 40 41 40 37 27 17 45.9 19 32 39 41 40 37 29 20 45.9 Low 17 30 37 39 38 34 23 15 43.4 18 30 37 39 38 35 25 17 43.8 High 21 31 41 42 41 38 29 20 46.9 21 30 40 41 41 38 32 24 46.6 500D Medium 21 31 40 42 41 38 28 19 46.5 21 31 40 41 40 38 31 23 46.2 Low 18 29 38 40 39 35 25 16 44.4 20 30 38 40 38 36 28 19 44.6 High 22 31 41 42 43 40 30 20 48.0 24 32 42 42 43 40 32 23 48.3 600D Medium 22 31 41 42 43 40 30 19 47.6 24 32 42 42 42 39 31 22 47.9 Low 19 30 38 39 40 37 26 15 44.7 23 31 40 41 41 37 28 19 46.2 High 24 34 43 47 45 41 31 24 50.5 24 35 43 47 44 41 33 27 50.4 800D Medium 23 33 43 46 44 40 31 24 50.1 23 35 43 46 44 41 33 26 50.0 Low 22 32 41 45 43 39 29 21 48.6 23 34 42 45 43 39 31 24 49.1 High 22 35 43 44 43 40 31 21 49.0 23 36 44 44 43 40 31 20 49.2 900D Medium 22 35 42 44 43 40 30 20 48.6 23 35 43 44 43 40 31 20 48.8 Low 21 33 40 42 41 38 28 17 46.7 22 35 42 42 41 38 29 18 47.4 High 24 36 43 43 45 39 31 21 49.2 25 35 43 43 45 40 31 21 49.4 1000D Medium 24 36 43 43 44 39 31 21 49.0 23 36 43 43 44 39 31 20 49.1 Low 22 35 41 42 42 36 28 18 47.1 23 34 41 42 43 37 29 18 47.4 High 28 35 45 48 51 44 37 29 53.9 29 35 46 48 51 45 37 30 54.0 1200D Medium 26 34 44 47 50 43 36 28 53.2 26 34 45 47 50 44 36 29 53.3 Low 23 31 40 44 46 39 30 22 49.5 27 31 41 45 47 39 31 22 49.9 High 27 38 45 47 50 45 41 36 53.7 27 39 45 47 50 45 41 36 53.6 1400D Medium 26 38 44 46 50 44 40 35 53.1 27 38 45 46 49 44 40 35 53.0 Low 23 34 41 43 46 41 36 29 49.6 24 36 41 44 47 41 37 30 50.3 Notes: 1. Microphone position: 1m in front of the unit and 1m below the vertical center line of the unit. 2. The sound level is tested under 11.5dBA background noise in a baffle chamber with ESP of 50 Pa and 75Pa. 8 ACWD_2006.indd 8 2006-5-25 17:24:48

Wiring Diagrams Electrical wiring connection must be done according to the following wiring diagram. The unit must be GROUNDED to the earth system of the building. All field wiring must be installed in accordance with the national wiring regulation and Fire Department regulation. MODEL: ACW 200~1400 POWER SOURCE H M L FAN SPEED SWITCH SHF HF MF LF L N RED YELLOW BROWN ORANGE RED YELLOW BROWN ORANGE FAN MOTOR FAN MOTOR BLUE BLUE BLACK BLACK BLACK 2 BLACK FAN MOTOR CAPACITOR FAN MOTOR CAPACITOR NOTE: SHF: SUPER HIGH SPEED HF: HIGH SPEED MF: MEDIUM SPEED LF: LOW SPEED FIELD WIRING FAN MOTOR2 APPLY TO 800~1400 UNITS 50~60Pa UNITS: (H,M,L) CONNECT TO (HF,MF,LF) 70~80Pa UNITS: (H,M,L) CONNECT TO (SHF,HF,MF) DRAWING NO.:M08024067082 Note: For ACWD series, (H. M. L.) are connected to (SHF. HF. MF.) respectively. 9 ACWD_2006.indd 9 2006-5-25 17:24:49

Outlines and Dimensions MODEL A A1 B C D E F G H I J K Fan No. Filters Size Qty 200D 714 814 484 448 487 547 534 150 251 105.5 143 218 1 502x244x25 1 300D 934 1034 704 668 707 767 534 150 251 105.5 143 218 2 722x244x25 1 400D 1014 1114 784 748 787 847 534 150 251 105.5 143 218 2 802x244x25 2 500D 1114 1214 884 848 887 947 534 150 251 94 143 218 2 902x244x25 2 600D 1214 1314 984 948 987 1047 534 150 251 94 143 218 2 1002x244x25 3 800D 1464 1564 1234 1198 1237 1297 534 150 251 94 143 218 3 1252x244x25 3 900D 1564 1664 1334 1298 1337 1397 534 150 251 94 143 218 3 13522x244x25 3 1000D 1664 1764 1434 1398 1437 1497 534 150 251 94 143 218 4 1452x244x25 3 1200D 1464 1564 1234 1198 1237 1297 599 200 295 94 193.8 262 3 1252x288x25 3 1400D 1664 1764 1434 1398 1437 1497 599 200 295 94 193.8 262 3 1452x288x25 3 FILTER FAN MOTOR FAN 6-R5*16 MOUNTING HOLES E D 24 TERMINAL BOX CONDENSATE DRAIN R 3/4 38 187 190 F a A(A1) C B 46 WATER RETURN CONNECTION Rc 3/4 I 15 20 15 25 K H G J WATER SUPPLY CONNECTION Rc 3/4 131 262 Notes: 1. All dimensions are in mm; 2. All standard units are with back air plenum and bottom removal filters; 3. A1 is the dimension for 100mm extended drain pan units; 4. Left hand coil connection shown; 5. Wiring connection side is the same as coil and drain connections. 10 ACWD_2006.indd 10 2006-5-25 17:24:49

Guide Specifications Unit Description Factory-assembled, horizontal, blow-thru type, galvanized casing, ceiling ducted fan coil unit is complete with water coil, fans, motors, drain pan, filters and all required wiring, with full access to internal components. Quality Assurance Each coil is factory tested for leakage at 3.3MPa air pressure with coil submerged in water. Each unit and its moving components (fans and motors) are factory computer-tested and recorded after unit is complete and before it is packed. Component Specifications 1.Casing Construction is of 0.8mm thickness galvanized steel, lined on the inside with 5mm PE thermal and acoustical insulation. Return air plenum is lined with 5mm PE foam and has a 20mm collar for return duct connection. Supply duct connection also has a 20mm long collar. Removable bottom panel is provided for access to the fan/motor assembly. 2. Coil Standard unit is equipped with a 4-row coil for installation in a 2-pipe system. Coil has 3/8 inch seamless copper tubes, slit type aluminum blue fins bonded to the tubes by mechanical expansion. Each coil has a manual air vent and two Rc3/4 water pipe connections with a working pressure of 1.6MPa. 3. Fan Direct-driven centrifugal fan wheel has forward-curved blades which are statically and dynamically balanced. The fan housing and blades are constructed of high quality hot-galvanizing steel. 4.Motor Fan motor is 3-speed, 220V-240V, single-phase, 50Hz, permanent split-capacitor type with ball type bearing and build-in automatic reset thermal overload protection. The motor s insulation is class B. 5. Drain pan The drain pan plate body is constructed of cold-rolled steel by way of integral cupping. Both its sides are sprayed with plastic coating. And its outer wall is lined with 6mm heat insulating PE foam and high quality adhesive by way of integral adhering and pressing. It extends under the full length and width of the coils and is pitched for positive drainage with features of high anti-corrosion, anti-condensation and high fire reluctance. 6. Filter Filter is with washable type double-layer nylon media in 25mm thickness aluminum frame. 11 ACWD_2006.indd 11 2006-5-25 17:24:50

R DOP: While upmost care is taken in ensuring that all details in the publication are correct at time of going to press, we are constantly striving for improvement and therefore reserve the rights to alter model specifications and equipment without prior notice. Details of specifications and equipment are also subject to change to suit local conditions and equirements and not all models are available in every market. ACWD_2006_Cover.indd 2 2006-5-25 17:24:07