McQuay. Incremental. MQE 007, 009, 012, 015, 016 MQR 007, 009, 012, 015 Vintage D. Last Manufactured: 2000

Similar documents
McQuay. Incremental. MQS Vintages A Vintage B. Last Manufactured: Replacement Parts List No Revision E 08/2017

McQuay. Incremental. PSEA, PSEC, PSEH, PSEI, PSES, PSHA, PSHC, PSHI, PSHS Suite II, 1 Motor 007, 009, 012, 015 Design A (1)

McQuay Climate Control Singer. Incremental. ES, RS, S 06, 09, 11, 14 Vintage B. Last Manufactured: 1991

McQuay. Incremental Packaged Terminal Air Conditioner. MQT Vintage B. Last Manufactured: 1994

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design D (4)

Daikin McQuay. Packaged Terminal Air Conditioner. PGAN 007, 009, 012, 015 Design 1. Replacement Parts List No Revision D 02/2015

Daikin McQuay. Incremental. PKEI, PKES, PKHS Design 2. Replacement Parts List No Revision A 07/2017

McQuay. Console Water Source Heat Pump. WMH, WMG, WMK, WCH, WCG 015, 019 Vintage A. Last Manufactured: 1993

McQuay. Console Water Source Heat Pump. WWDU Design A. Last Manufactured: Replacement Parts List No Revision A 07/2017

AAF. Water Source Heat Pump Ceiling Mounted. CCW Vintage E. Last Manufactured: Replacement Parts List No Revision D 08/2016

McQuay. Concealed Ceiling Water Source Heat Pump. WCAE, WCAS, WCDA, WCDL, WCDS, WCMS 024, 030 Design A (1)

McQuay. Enfinity Vertical Water Source Heat Pump. WFCV, WFCW Design 1. Replacement Parts List No Revision D 03/2018

McQuay. Ceiling Concealed Horizontal Water Source Heat Pump. CCH, CCG, CCW 048, 060 Vintage A. Last Manufactured: 1995

Daikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 007, 009, 012 Design 1. Replacement Parts List No Revision M 11/2017

Daikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 1. Replacement Parts List No Revision O 11/2017

Daikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 1. Replacement Parts List No Revision R 11/2018

McQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW, UC, UG, UW Vintages E, F, G. Last Manufactured: 1988

McQuay. Vertical Water Source Heat Pump. FCV, FCG, FCW 036, 042 Vintage A. Last Manufactured: 1993

Daikin. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 2. Replacement Parts List No New 11/2017

McQuay. Large Vertical Water Source Heat Pump. LGP, LHP, LWP Vintage C. Last Manufactured: 1994

McQuay. Water Source Heat Pump Ceiling Mounted. CCW Vintage E. WCDD, WCDE, WCMG Design A (1) WCDD, WCDE Design B (2)

Daikin. Self-Contained Unit Ventilator. UAEQ 036, 044, 054 Design H (8) Replacement Parts List No New 11/2017

Climate Control Singer. Incremental Comfort Systems. KS, EKS Vintage B. Last Manufactured: 1982

McQuay. Commercial Unitary Rooftop. CUR Vintage G. Last Manufactured: Replacement Parts List No Revision A 11/2016

McQuay. Applied PTAC Air Conditioner and Heat Pump PDAC, PDAA, PDAE, PDAN, PDAF PDHP, PDHA, PDHE, PDHF Design 1

Daikin McQuay. Applied PTAC Air Conditioner and Heat Pump. PDAA, PDAE, PDAF, PDAN, PDHA, PDHE, PDHF Design 3

McQuay. Seasonmaker ThinLine Horizontal Fan Coil. TSH, TSC Vintage F. FTSH, FTSC Designs A(1), B(2) Last Manufactured: 2008

McQuay. Self-Contained Unit Ventilator. UAZQ, UAZR, UAZU Design G (7) Replacement Parts List No Revision D 08/2018

Air Cooled Scroll Compressor Condensing Unit

McQuay. Roofpak Roof Mounted Air Handler Draw- Through. RDS Size: 900 Vintage: B. Last Manufactured: 1998

McQuay. Aircon Air Cooled Condenser. AMB, APB AMD, APD Vintage A. Last Manufacture: 1978

Type K Incremental Packaged Terminal Air Conditioner

McQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS 030, 035, 040, 050 Vintage A, E

McQuay Acson. Ductless Split System Indoor Ceiling Cassette ACK-A, ACK-AR MCK-A, MCK-AR Last Manufactured: 2007

Catalog Daikin Type K. Incremental Room Conditioner. Engineered for flexibility and performance

McQuay. Templifier Scroll Compressor Water Heater. TGZ Vintage A. Replacement Parts List No Revision E 04/2016

McQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS 020, 025 Vintage E. Replacement Parts List No Revision J 02/2018

Applied Packaged Terminal Air Conditioner with Catalog Top-Mounted Hydronic Heat

CABINET PARTS For Models: 7GS2SHEXPQ03, 7GS2SHEXPL03 (White) (Stainless VCM) REFRIGERATOR

CABINET PARTS For Models: ED5LHEXTD00 (Universal Silver)

CABINET PARTS. For Models: ASD2522WRW01, ASD2522WRB01, ASD2522WRS01, ASD2522WRD01 (White) (Black) (Stainless) (Universal Silver)

McQuay. Screw Chiller Water Cooled. WHS Vintage A. Last Manufactured: Replacement Parts List No New 07/2012

CABINET PARTS For Models: ASD2522WRS07 (Stainless)

SCE170 SERVICE PARTS

ICE AIR LLC. Draw1 REV. - PERFORMANCE DATA 117/133 COOLING CAPACITY CORRECTION FACTORS HEATING CAPACITY CORRECTION FACTORS

R22C/H Packaged Terminal Air Conditioner (PTAC) Specifications and Performance. The Right Fit for Comfort

Incremental Comfort Conditioners

CABINET PARTS. For Models: ED5SHAXMQ00, ED5SHAMXT00, ED5SHAXMB00 (White) (Biscuit) (Black) REFRIGERATOR. Part No Rev.A

25 CUBIC FOOT SIDE BY SIDE REFRIGERATOR MODELS: WRS325FDAW02 (White) WRS325FDAB02 (Black) WRS325FDAT02 (Biscuit) WRS325FDAM02 (Stainless)

Series PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection

CABINET PARTS For Models: ASD2522WRW03, ASD2522WRB03, ASD2522WRS03, ASD2522WRD03 (White) (Black) (Stainless) (Universal Silver)

Parts List. Refrigerated Kitchen Equipment Models Refrigerated Prep Table with Raised Rail. hoshizakiamerica.com

WHIRLPOOL REFRIGERADOR GS2SHGXLQ01

R21C Packaged Terminal Air Conditioner (PTAC) Specifications and Performance. The Right Fit for Comfort R21C. Straight Cooling Nominal Capacities

Repair Parts List REFRIGERATOR MODEL NUMBER LTF2112ARB. When requesting service or ordering parts, always provide the following information:

Specifications and Performance

CABINET PARTS For Models: MSD2553WEW01, MSD2553WEB01, MSD2553WEM01 (White) (Black) (Stainless Steel)

SIDE BY SIDE REFRIGERATOR MODELS: WRS325FDAW04 (White) WRS325FDAB04 (Black) WRS325FDAT04 (Biscuit) WRS325FDAM04 (Monochromatic Stainless)

CABINET PARTS For Model: ED5GTGXNQ14, ED5GTGXNB14 (White) (Black)

CABINET PARTS. For Models: GS5SHAXNQ02, GS5SHAXNT02, GS5SHAXNB02, GS5SHAXNS02, GS5SHAXNL02 (White) (Biscuit) (Black) (Stainless Steel) (Stainless VCM)

CABINET PARTS REFRIGERATOR. For Models: ED5VHGXMQ00, ED5VHGXMT00, ED5VHGXMB00 (White) (Biscuit) (Black) 8 03 Litho In U.S.A. (kdj)

SIDE BY SIDE REFRIGERATOR MODELS: WRS325FDAW04 (White) WRS325FDAB04 (Black) WRS325FDAT04 (Biscuit) WRS325FDAM04 (Monochromatic Stainless)

McQuay. Unit Ventilators Self-Contained UAED, UAEQ, UAER, UARQ, UERQ, UAZQ, UAZR, UAZS, UAZU, UAZV Designs D (4), E (5)

Daikin McQuay. Templifier Scroll Compressor Water Heater. TGZ Vintage B. Replacement Parts List No Revision F 11/2017

CU1526, CU2026, CU3030 Service Parts

Specifications and Performance

McQuay Type J Series Incremental Conditioner

McQuay. Roofpak Condensing Unit Medium Cabinet, Standalone. RCS Tons Vintage C Code 12= 1A, 2A. Valid for units built 06/2010 & Earlier

CABINET PARTS For Models: GS6SHAXKQ01, GS6SHAXKT01, GS6SHAXKB01, GS6SHAXKS01 (White) (Biscuit) (Black) (Stainless Steel)

CABINET PARTS For Model: KSF26C6XYY00 (Monochromatic Stainless)

McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage G. Replacement Parts List No Revision C 09/2018

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.

CABINET PARTS For Models: ED5RHEXNL00 (Stainless VCM)

CABINET PARTS. For Models: GD2SHAXNQ00, GD2SHAXNT00, GD2SHAXNB00, GD2SHAXNS00, GD2SHAXNL00 (White) (Biscuit) (Black) (Stainless Steel) (Stainless VCM)

CABINET PARTS REFRIGERATOR

CMS1402 SERVICE PARTS

Service Parts Manual Integrated (700-(

CABINET PARTS For Models: GS5VHAXWQ00, GS5VHAXWB00, GS5VHAXWY00, GS5VHAXWA00 (White) (Black) (Monochromatic (Monochromatic Satina) Stainless)

CABINET PARTS Printed In U.S.A. (mat) Part No. W Rev. B

CABINET PARTS REFRIGERATOR. For Models: GD2SHAXKQ03, GD2SHAXKT03, GD2SHAXKB03 (White) (Biscuit) (Black) 5 02 Litho In U.S.A. (mek) 1. Part No.

COS-101 NON SELF FLUSHING COMBI REPLACEMENT PARTS LIST

Series PIC. New Construction and Renovation; Replaces RetroAire VPAC and First Company DPU Application Flexible Quiet Comfort Damage Protection

RC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

CABINET PARTS For Models: KSC24C8EYW00, KSC24C8EYB00, KSC24C8EYP00, KSC24C8EYY00 (White) (Black) (Stainless) (Monochromatic Stainless)

AFE400 SERVICE PARTS

Hoshizaki America, Inc.

R11C R12C R21C R22C/H R23C/H R24C/H

KSRG25FKWH18, KSRG25FKBL18, KSRG25FKBT18

Repair Parts List REFRIGERATOR MODEL NUMBER GC20B8C3EB. When requesting service or ordering parts, always provide the following information:

MARVAIR CLASSIC HEAT PUMPS MODELS AVP HP EXPLODED VIEW PARTS ID

REPAIR PARTS LIST REFRIGERATOR. Model No.(s) (White) (Stainless Steel) (Black)

CABINET PARTS REFRIGERATOR. For Models: ED25PQXFW00, ED25PQXFN00 (White) (Almond) Litho In U.S.A. (mdg) 1. Part No

Front Roller (2) Screw Roller (Rear) (2) Screw Clip, Grille Screw Shim

DDBF036 SERIES 10 : REFRIGERATOR DOOR [1/12]

CABINET PARTS For Models: KSRG22FKWH17, KSRG22FKBT17, KSRG22FKBL17 (White) (Biscuit) (Black)

PAC SERIES - 13 SEER SINGLE PACKAGED AIR CONDITIONER (GEN 3, STYLE A)

CABINET PARTS For Models: W8RXNGMWB02, W8RXNGMWS02, W8RXNGMWL02 (Black) (Stainless Steel) (Satina)

CABINET PARTS For Models: ED25UEXHW01, ED25UEXHT01 (White) (Biscuit)

CABINET PARTS. For Models: MSD2269KEW02, MSD2269KEB02, MSD2269KEY02, MSD2269KEA02 (White) (Black) (Stainless Steel)(Monochromatic Satina)

Transcription:

Replacement s List No. 5709900 Revision N 0/205 McQuay Incremental MQE 007, 009, 02, 05, 06 MQR 007, 009, 02, 05 Vintage D Last Manufactured: 2000 To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

Contents s List Revision History... 3 Nomenclature Serial... 4 Model... 5 Electrical Legend... 6 Refrigeration Components... 7 Refrigeration Circuit- HP Units... 8 Indoor Blower Section... 9 Heater and Evaporator Coil... 0 - Outdoor Coil and Fan... 2 Controls Slope Top Control Assembly (ACO & MCO)- Diagram... 3 Slope Top Control with Remote- Diagram... 4 Flat Top Control Assembly (Extendaire & NYC Style)- Diagram... 5 Slope Top & Flat Top Control- Components... 6-8 Subbase and Fused Disconnect... 9 Damper... 20 New York City Hydronic Unit... 2 Field Installed Options... 22 Critical s List MQE, MQR 007, 009... CPL MQE 02, 05, 06; MQR 02, 05... CPL2 PTAC; MQE, 007-06 MQR, 007-05 Vintage D Rev. N 0/5 RPL 57099 /Page 2

s List Revision History Revision Date Description A 2/96 Updated RPL layout to be consistent w/ OnLine format, this resulted in adding one page. B 0/97 Corrected Fan Relay (#27) part number to 609402 (was 629402) on page 8. C /97 Page 5- Added Compressor size 02,, NYC. Page 7- Correct p/n forthermostat, Low Temp. D 08/98 Added size 06 (see last pages for supplemental information). Added supplemental pages (33 & 34) for sizes 02, 05 & 06 -, and 06-208/. Added footer to reflect supplemental information added. Page 5 - Moved Compressor for size 02-, NYC to page 33. Page 8 - Ref. # 24- Added aluminum to description and changed p/n. Ref. # 27- Fan Panel p/n changed. Page 0- Ref. # 38- Electric Heater model number heater code letters added. Ref. # 39- Thermoswitch for 25o added. Valve Hot Water descriptions changed. Page 8- Added Terminal Board 62060 (bubble 28). Page 9- Ref. # 38- p/n changed. Pages 33 & 34 - Added these 2 pages, Supplemental Information for sizes 02, 05, 06. E /99 Page 0 - Updated part number for Cover, Indoor Coil on sizes 02 & 05 (Bub.# 36). Page 2 - Updated part numbers for Coil, Outdoor Coated on all sizes (Bub.# 52). Page 33 - Updated part number for Heater/Evap Coil Capillary. F 0/0 Page 24 - Added damper door diagram & components list. G 0/0 Page 6 - Added notes and arrow to diagram bubbles 24 and 25. Page 7 - Ref. # 24; Change L.H & R.H. Blower Wheel from aluminum to metal. Change L.H. wheel p/n to 5679950. Change R.H. wheel p/n to 5679940. H 08/0 Revise notes and add Hydronic Subbase units only & Electric Heat, Heat Pump, NYC only notes. I 05/03 Updated all part numbers to current McQuay format. Page 5- Add Electrical Legend All subsequent pages changed by one. Page 6-35 MFD/370V capacitor p/n changed to 802007849. Page 9- Ref. # 23 added 06255080 for sizes 02/05 and modified quantities. Page - Ref. # 36 p/n for sizes 007,009 changed to 05546589. Page - Ref. # 36 p/n for sizes 007,009 changed to 05546589. Ref. # 37 p/n for sizes 007/009 & 02/05 changed to 82009306 & 82009307. Page 22- Ref. # 92 p/n changed to 0623239. Page 24- Change Ref. # 0 p/n to 05632590 and Ref. # p/n to 06232365. Change Ref. # 2 p/n to 06232309. U spring nut p/n add for units built after 4/97. Page 27- Ref. # 4 p/n changed to 06232390 and ref. # changed to N/S. Ref. # 42, 43 3 components italicized and note added. J /05 Page 9 - Added * footnote. Page 2 - Bubbles #2 & #23 p/n changed from 0678040 to 06680390. K 2/09 Pages, 24, 27, 28, 3 - Note change to McQuay s. L 05/09 Pages, 32- Remove p/n 8020260 for 3-way valve. Add 3-way Valve Body p/n 0623360 and 3-Way Valve Actuator p/n 623380. M 05/2 Rebrand to Daikin Mcquay. Formatted to CS5.5. Delete vendor part numbers. Page 4- Add Serial for 2/999 to present. Pages 34-35 Numerous changes. CPL- Add Critical s List. N 0/5 All Pages- Update to Daikin format. Delete sheet metal and add footnote #. Change all note references from McQuay to Daikin. Numerous changes done. Add Supplemental Information for unit size 06 (208/) to RPL. Page 5- Add Model - updated to complete code. Pages 22-23 Delete Supplemental Information pages. CPL-CPL2 Update Critical s List to Daikin format and add Supplemental Info for size 6. Divide CPL as MQE, MQR 007-009 & CPL2 as MQE 02-6 /MQR 02-05. Daikin Applied, 3600 Industrial Park Blvd., P.O. Box 55, Minneapolis, MN 55440 (763) 553-5330 PTAC; MQE, 007-06 MQR, 007-05 Vintage D Rev. N 0/5 RPL 57099 /Page 3

Nomenclature Serial Before /95 7 X A 00000 00 Plant Identification 7 = Auburn Year Manufactured X = 992 Y = 993 Z = 994 Etc. Engineering Revision Serial (Building Sequence) Month Manufactured A = January B = February C = March D = April E = May F = June G = July H = August J = September K = October L = November M = December Serial /95 and After 7 5 A 00000 00 Plant Identification 7 = Auburn Year Manufactured 5 = 995 6 = 996 7 = 997 8 = 998 9 = 999 Etc. Engineering Revision Serial Month Manufactured A = January B = February C = March D = April E = May F = June G = July H = August J = September K = October L = November M = December PTAC; MQE, 007-06 MQR, 007-05 Vintage D Rev. N 0/5 RPL 57099 /Page 4

Nomenclature Model MQE 02 D 0 25 S Y A E D F L YYY YY Code 0 02 03 04 05 06 07 08 09 0 2 3 4-6 7 8-9 Code 0= Unit Type MQE= Suite A/C w/electric or Hydronic Heat MQR= Suite Heat Pump Code 02= Unit Size 007= 7,000 Nominal Cooling Btuh 009= 9,000 Nominal Cooling Btuh 02= 2,000 Nominal Cooling Btuh 05= 5,000 Nominal Cooling Btuh 06= 6,000 Nominal Cooling Btuh Code 03= Vintage D= Vintage D Code 04= Unit Voltage = 5/60/ 03= 208/60/ 0= 230/60/ 47= 265/60/ Code 05= Heater Code 2= 2. KW Electric Resistance Heater 25= 2.5 KW Electric Resistance Heater 32= 3.2 KW Electric Resistance Heater 4= 4. KW Electric Resistance Heater 45= 4.5 KW Electric Resistance Heater HW= Hot Water Heat ST= Steam Heat Code 06= Chassis Type S= Slope Top F= Flat Top N= Flat Top, NYC Style- Hydronic Heat Code 07= Always Y Code 08= Controls M= Manual Chageover (MCO) P= MCO + Night Setback (NSB) Q= MCO + Guest Room Control (GRC) T= MCO+ NSB + GRC G= MCO with Heat/Fan Lockout A= Auto Chageover (ACO) B= ACO + Night Setback (NSB) C= ACO + Guest Room Control (GRC) D= ACO+ NSB + GRC L= Remote Stat (24V Control) S= Stand-by Power Code 09= Damper Options = Manual Fresh Air Damper 2= Motorized Fresh Air Damper 3= None Code 0= Configeration E= Chassis, Front Panel and Uninsulated Wall Sleeve F= Chassis and Front Panel Only G= Chassis Only H= Chassis, Front Panel, and Insulated Wall Sleeve Code = Drefrost Control Option D= With Defrost Control Y= None Code 2= Fan Cycle Option F= With Fan Cycle Y= None Code 3= Thermostat Limiter Option L= With Limiter Y= None Codes 4-6= Always YYY Code 7= Corrosion Protection = Sea Coast Construction Y= None Codes 8-9= Always YY Code 20= Agency Listing Code 2= Performance Listing Code 22= Warranty Code 23= Nameplate Code 24= Always Y Code 25= Packaging Code 26= Miscellaneous PTAC; MQE, 007-06 MQR, 007-05 Vintage D Rev. N 0/5 RPL 57099 /Page 5

Electrical Legend Sch. Sym. C C2 DM HL HV MP P P3 R R2 R3 R4 R5 R6 R7 R8 R9 RV S S2 S3 S4 T T2 TB TB2 TB3 TC TC3 TC7 Description Capacitor- Compressor Capacitor- Fan Motor Damper Motor Hi Limit Switch- Electric Heat Heat Valve Motor Protector- Compressor Plug- Chassis Plug- Heating Valve Relay- Guest Room Control Relay- Night Setback Relay- Compressor Relay- Fan Cycle Relay- Heat Relay- Fan Relay- Cool Relay- Stand By Power Relay- Defrost Reversing Valve (MQR) Switch- Control Switch- Power Switch- Fan Cycle Switch- Damper Transformer- Heat Valve Transformer- Heat Valve Terminal Board- Control Board Terminal Board- Chassis Terminal Board- Remote Control Box Thermostat- Room Thermostat- Changeover Freezestat PTAC; MQE, 007-06 MQR, 007-05 Vintage D Rev. N 0/5 RPL 57099 /Page 6

Refrigeration Components Unit Size/ Quantity Ref. No. Description 007 009 02 05 06 N/S Grommet, Compressor Mount 06062330 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 N/S Sleeve, Compressor Mount 06062340 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 N/S Nut, Compressor Mount 80202035 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 Compressor 0665390 Compressor 06653902 Compressor 06653903 Compressor 06086003 Compressor 06086002 N/S Compressor 0608600 Compressor 06090780 Compressor 060907802 Compressor 0604340 Compressor 06043402 Compressor 06654030 Compressor 062242927 Compressor 062242925 Compressor 062242928 Compressor 062242929 N/S Compressor 062242924 Compressor 062242923 Compressor 06224296 Compressor 06224297 Compressor 062242920 Compressor 06224292 Overload, Compressor 06653670 Overload, Compressor 06653680 Overload, Compressor 06653690 Overload, Compressor 06689603 N/S Overload, Compressor 06689602 Overload, Compressor 0668960 Overload, Compressor 0609930 Overload, Compressor 06099302 Overload, Compressor 06099305 Overload, Compressor 06099306 Capacitor, 35MFD 370V 802007849 N/S Capacitor, 5MFD 440V 06729508 Capacitor, 25MFD 370V 0672952 Capacitor, 25MFD 440V 0672957 N/S= Not shown. = Sea Coast units only. PTAC; MQE, 007-06 MQR, 007-05 Vintage D Rev. N 0/5 RPL 57099 /Page 7

Refrigeration Circuit- HP Units Indoor Coil 3 3 Size 05 Sizes 007, 009, 02 Process Suction 2 Outdoor Coil Discharge Capillary Compressor Reversing Valve Process Unit Size/ Quantity Ref. No. Description 007 009 02 05 06 Reversing Valve * 06653360 N/S Reversing Valve * 0672840 Reversing Valve * 06653370 Solenoid, Reversing Valve * 06654902 N/S Solenoid, Reversing Valve * 06654903 Solenoid, Reversing Valve * 06654904 N/S Strainer 05630330 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Strainer 2 05630330 Capillary- Cool 060634746 N/S Capillary- Cool 8020008 Capillary- Cool 8020077 Capillary- Cool 802009 Thermostat, Indoor Coil 0606600 2 Thermostat, Outdoor Coil 0606600 3 Freezestat 06654740 N/S= Not shown. = Heat Pump units only. 2 = A/C units only. * The new and old valves/solenoids are not compatible. If a new valve is ordered to replace an old style valve, a new solenoid coil must also be ordered. Refer to Ranco Reversing Valve Form No. 57039. PTAC; MQE, 007-06 MQR, 007-05 Vintage D Rev. N 0/5 RPL 57099 /Page 8

Indoor Blower Section Outdoors NOTE: Right-hand Blower Wheel mounted with hub towards motor. 27 24 30 30 23 29 28 26 25 NOTE: Left-hand Blower Wheel mounted with hub towards motor. 2 22 28 29 24 25 Unit Size/ Quantity Ref. No. Description 007 009 02 05 06 Motor, Indoor 06085370 Motor, Indoor 060853702 Motor, Indoor 060853703 2 Motor, Indoor 060853704 Motor, Indoor 0695802 Motor, Indoor 0695803 Motor, Indoor 0695804 22 Clip, Motor Mount 06090050 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 23 Mount, Motor 0608770 Mount, Motor 06255080 Blower Wheel, Plastic 06064200 2 2 2 2 2 2 2 2 24 Blower Wheel, LH 05679950 Blower Wheel, RH 05679940 25 Hub Clamp, Blower Wheel 060642002 2 2 2 2 2 2 2 2 26 Clamp, Thermostat 8020753 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 27 Panel, Fan 28 Scroll Wrap 06064030 2 2 2 2 2 2 2 2 Scroll Wrap 069630 2 2 2 2 2 2 2 2 29 End Plate, LH 82009236 2 2 2 2 2 2 2 2 End Plate, LH 069620 2 2 2 2 2 2 2 2 30 End Plate, RH 82009237 2 2 2 2 2 2 2 2 End Plate, RH 0696202 2 2 2 2 2 2 2 2 Please contact Daikin with unit model and serial number for part numbers or cabinet/chassis components. PTAC; MQE, 007-06 MQR, 007-05 Vintage D Rev. N 0/5 RPL 57099 /Page 9

Heater and Evaporator Coil 36 35 37 38 39 40 Unit Size/ Quantity Ref. No. Description 007 009 02 05 06 Coil, Indoor 0569240 35 Coil, Indoor 0569670 Coil, Indoor 0569260 Coil, Indoor 0569270 36 Cover, Indoor Coil Electric Heater * 80202230 a a Electric Heater * 8020223 a b a b Electric Heater * 80202232 a b c a b c Electric Heater * 80202233 b c d b c d Electric Heater * 80202234 c d c d Electric Heater * 80202235 d d 37 Electric Heater * 80202237 a a Electric Heater * 80202238 a b a b a Electric Heater * 80202239 a b c a b c a b Electric Heater * 80202240 b c d b c d b c Electric Heater * 8020224 c d c d c d Electric Heater * 80202242 d d d Electric Heater * 80202243 e e e * Letters correspond to Heater Code (Code 05) a: 2 = 2. kw Electric Heat d: 4 = 4. kw Electric Heat b: 25 = 2.5 kw Electric Heat e: 45 = 4.5 kw Electric Heat c: 32 = 3.2 kw Electric Heat Please contact Daikin with unit model and serial number for part numbers or cabinet/chassis components. Continued on next page. PTAC; MQE, 007-06 MQR, 007-05 Vintage D Rev. N 0/5 RPL 57099 /Page 0

Heater and Evaporator Coil Components- Continued Unit Size/ Quantity Ref. No. Description 007 009 02 05 06 38 Drain Pan 82009306 Drain Pan 82009307 Thermo Switch, 25 F 06700080 39 Thermo Switch, High Limit 0790250 Thermo Switch, High Limit 802005907 Thermo Switch, High Limit 2 06780 40 Thermo Switch, Discharge Air 3 0606430 N/S Hydronic Coil 4 80200428 N/S 2- Way Valve, Steam, NC 802026093 N/S 2- Way Valve, HW, NO 802026092 N/S 3- Way Valve, HW, NO, Body 0623360 3- Way Valve, HW, NO, Act. 0623380 N/S Drain Valve 3 80202696 N/S = Not shown on diagram. 2 Used with heater size D & E only 3 Heat Pump Units only. 4 For Hot Water or Steam. PTAC; MQE, 007-06 MQR, 007-05 Vintage D Rev. N 0/5 RPL 57099 /Page

Outdoor Coil and Fan 50 5 54 52 55 53 Unit Size/ Quantity Ref. No. Description 007 009 02 05 06 50 Set Collar- Fan Prop 0606650 5 Fan Prop with Clamp 063830 Outdoor Coil 0569230 52 Outdoor Coil 0569490 Outdoor Coil, Coated 2 056886302 Outdoor Coil, Coated 2 056886502 Motor, Outdoor 064503 Motor, Outdoor 06450 53 Motor, Outdoor 064502 Motor, Outdoor 2 06224283 Motor, Outdoor 2 0622428 Motor, Outdoor 2 06224282 Capacitor, 5MFD 370V 06729503 N/S Capacitor, 4MFD 370V 06729502 Capacitor, 3MFD 440V 0672954 N/S Strap, Capacitor 060642202 54 Motor Mount 0634860 55 Plenum Assy 0639060 N/S = Not shown on diagram. 2 Sea Coast units only. PTAC; MQE, 007-06 MQR, 007-05 Vintage D Rev. N 0/5 RPL 57099 /Page 2

Slope Top Control Assembly (ACO & MCO) Diagram R9 34 33 32 3 30 7 2 7 TC2 R3 26 29 T R4 27 P 35 S4 9 3 TC 8 S3 25 R2 (NSB) 20 R (GRC) 37 28 P3 TB S 5 PTAC; MQE, 007-06 MQR, 007-05 Vintage D Rev. N 0/5 RPL 57099 /Page 3

Slope Top Control with Remote Diagram 7 4 S2 2 R5 R6 22 T2 29 T 29 P 35 23 R7 S4 9 P3 37 P2 36 38 28 TB 28 TB3 PTAC; MQE, 007-06 MQR, 007-05 Vintage D Rev. N 0/5 RPL 57099 /Page 4

Flat Top Control Assembly (Extendaire & NYC Style) Diagram 7 2 9 0 6 5 3 TC 25 R2 (NSB) R3 26 29 T 27 R4 9 S4 7 TC2 (NSB) 20 R GRC 8 S3 28 TB PTAC; MQE, 007-06 MQR, 007-05 Vintage D Rev. N 0/5 RPL 57099 /Page 5

Slope Top & Flat Top Control Components Unit Size/ Quantity Ref. No. Description 007 009 02 05 06 Cord, Power, 20A * 0622807 y y Cord, Power, 5A * 0622805 t v t v t v t v t v Cord, Power, 20A * 062280 u u u u u Cord, Power, 20A * 062280 w w w w w w w w w w Cord, Power, 30A * 0622806 x x x x x x x x x x Cord, Power, 20A * 0622804 z z z z 7 Label Control, 4 06687902 Label Control 2, 4 05795540 Label Control 2, 3 05795560 Label Control 2, 5 05795550 9 Washer, Top 82009757 0 Washer, Bottom 82009758 Arm Pivot 0554950 2 Knob, Bar, 4 0636590 Knob, Knurled, 5 8020803 Knob, Bar- Tstat & Switch 2 0590360 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 Thermostat 4 TC 06700040 Thermostat 5 TC 06582990 4 Rocker, Switch 2, 3 S2 047357307 Switch, 6 Button, 5 06065330 5 Switch, Rotary, 3 Position 2, 4 0590590 Switch, 3 Button, 3, 4 047358503 Switch, Rotary, 7 Position 2, 5 0590600 Switch, Push Button, Black 67072-8 6 Switch, Push Button, White 67072-0 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 Switch, Push Button, Blue 67072-36 Switch, Push Button, Red 67072-82 Flat Top. 2 Slope Top. 3 Remote Control. 4 Automatic Changeover. 5 Manual Changeover. 6 Letters correspond to Heater Code (Code 05) t= 2 w= ST, HW, 32 u= 25 x= 4, 45 v= 2, 25 y= ST, HW Z= ST, HW, 2, 25, 32, 4, 45 Continued on next page. PTAC; MQE, 007-06 MQR, 007-05 Vintage D Rev. N 0/5 RPL 57099 /Page 6

Slope Top & Flat Top Control Components- Continued Unit Size/ Quantity Ref. No. Description 007 009 02 05 06 N/S Tstat, Low Temp 059026902 7 Tstat, NSB TC2 0609670 Tstat, NSB 2 TC2 05679430 8 Switch, Toggle S3 80300509 9 Switch, Damper S4 802005045 20 Relay, Time Delay R 8030059 2 Relay, Heat 3 R5 06680390 22 Relay, Fan 3 R6 80200589 23 Relay, Cool 3 R7 06680390 Relay, NSB 4, 5,6 R2 80300534 Relay, NSB 4, 5,6 R2 8030052 Relay, NSB 4, 5,6 R2 80300520 25 Relay, NSB 5, 7 R2 8030052 Relay, NSB 5,7 R2 80300520 Relay, NSB 4, 7 R2 8030053 Relay, NSB 4, 7 R2 80300533 N/S Relay, Std-By-Power R8 80300534 Relay, Compressor 6 R3 80300534 26 Relay, Compressor 6, 7 R3 8030052 Relay, Compressor 6, 7 R3 80300520 Relay, Fan Cycle 7, 8 R4 8030052 Relay, Fan Cycle 7, 8 R4 80300520 Relay, Fan Cycle 6, 8, 0 R4 0609404 27 Relay, Fan Cycle 6, 8, 0 R4 060940 Relay, Fan Cycle 6, 8, 0 R4 0609402 Relay, Fan Cycle 6, 9 R4 80300534 Relay, Fan Cycle 6, 9 R4 8030052 Relay, Fan Cycle 6, 9 R4 80300520 N/S = Not shown on diagram 3 = Remote Control 4 = Automatic Changeover 5 = Manual Changeover 6 = MQE 7 = MQR 8 = Electric Heat 9 = Hot Water Heat 0 = Steam Heat Continued on next page. PTAC; MQE, 007-06 MQR, 007-05 Vintage D Rev. N 0/5 RPL 57099 /Page 7

Slope Top & Flat Top Control Components- Continued Unit Size/ Quantity Ref. No. Description 007 009 02 05 06 Terminal Board 3 TB, TB3 802007090 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 28 Terminal Board TB 802007090 Terminal Board TB3 802007055 Terminal Board TB2 062060 Transformer T 802005859 Transformer T 802005860 Transformer T 80200586 29 Transformer T 802005862 Transformer T, T2 802005859 2 2 Transformer T, T2 802005860 2 2 2 2 2 Transformer T, T2 80200586 2 2 2 2 2 Transformer T, T2 802005862 2 2 2 2 30 Clip, Adjusting 0630290 3 Clamp 06302920 32 Arm, Stat Limit 059060 33 Screw 000566500 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 34 Relay, Defrost R9 8030052 Relay, Defrost R9 80300520 35 Plug, 5 Ckt P 034622000 36 Plug, 6 Ckt P2 047934203 37 Plug, 2 Ckt P3 03825480 38 Receptacle, 6 Ckt 047934204 N/S = Not shown on diagram. Remote Control with Steam or Hot Water Heat. PTAC; MQE, 007-06 MQR, 007-05 Vintage D Rev. N 0/5 RPL 57099 /Page 8

Subbase and Fused Disconnect 45 Electric Subbase Hydronic Subbase Receptacle 53 Disconnect Switch 40 Fuse Disconnect Switch 50 56 Fuse Receptacle 58 59 Unit Size/ Quantity Ref. No. Description 007 009 02 05 06 Subbase- Electrical and Hydronic 40 Front Subbase 45 Side Extension 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 50 Subbase 53 Hydronic Coil 80200428 56 Filter, Permanent 80200820 Filter, Permanent 2 8020082 58 Grille, Front Panel 05704689 59 Latch 8020803 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Fused Disconnect Fuse, 5A 04928306 N/S Fuse, 20A 04928307 Fuse, 25A 80200763 Fuse, 30A 04928308 N/S Disconnect Switch, 30A 4EAL4022 Disconnect Switch, 40A 030059 N/S = Not shown on diagram. Please contact Daikin with unit model and serial number for part numbers or cabinet/chassis components. PTAC; MQE, 007-06 MQR, 007-05 Vintage D Rev. N 0/5 RPL 57099 /Page 9

Damper Unit Size/ Quantity Ref. No. Description 007 009 02 05 06 Damper Motor, 802024036 N/S Damper Motor, 80202405 Damper Motor, 802024037 Damper Motor, 80202406 N/S Manual Damper Arm 06064440 N/S Damper Door Assy 82009588 N/S Channel Operating Arm N/S Damper Operator Cable 8200958 N/S = Not shown. Please contact Daikin with unit model and serial number for part numbers or cabinet/chassis components. PTAC; MQE, 007-06 MQR, 007-05 Vintage D Rev. N 0/5 RPL 57099 /Page 20

New York City Hydronic Unit Components Ref. No. Description N/S Coil, Hot Water, RH Connections 802004344 Coil, Hot Water, LH Connections 802004345 Coil, Hot Water, Opposite Connections 802004369 N/S Coil, Steam, RH Connections 802004347 Coil, Steam, LH Connections 802004348 Coil, Steam, Right Supply, Left Return 802004367 Coil, Steam, Left Supply, Right Return 802004368 N/S 2-Way Valve, Hot Water, NO 802026092 2-Way Valve, Steam, NC 802026093 3-Way Valve, Hot Water, NO 8020260 N/S Switch, Heat Fan Lockout 0628870 N/S Clip, Heat Fan Lockout 06288802 N/S Relay, Heat Fan Lockout 802005490 N/S Disconnect Switch 802005374 N/S Control Door 056389489 N/S Frame, Control Door 06232389 N/S Discharge Grille 056390989 N/S = Not shown. PTAC; MQE, 007-06 MQR, 007-05 Vintage D Rev. N 0/5 RPL 57099 /Page 2

Field Installed Accessories Description Flush - Stamped Louver 829008402 Architectural Louver, No End Cap 06653920 Architectural Louver, With End Cap 066539202 Louver Frame 0605450 Receptacle, 5A 8020079 Receptacle, 20A 04739805 Receptacle, 30A 04739804 Receptacle, 20A 04739802 Plug/Cord Cover 0637500 Extendaire Primary Discharge Section 0632640 Extendaire 3-Foot Duct 06325802 MCO Wall Thermostat / Subbase 803005245 ACO Wall Thermostat 06068530 Wall Subbase, ACO 06068480 Wall Sleeve, Weather Panel, Non-Insulated 06323602 Wall Sleeve, Weather Panel, Insulated 06323602 Leveling Screw, Wall Sleeve (Qty = 4) 049990 Drain Kit Indoor/Outdoor 06324702 Cabinet Accessories- Slope Top End Cap, Plastic (Qty = 2) 0635650 Grille, Plastic (Qty = 4) 0635640 Access Door, Plastic, Spillproof 0635700 Frame, Access Door, Plastic, 0 063570 End Panel, Plastic, Slope Top, RH 05630420 End Panel, Plastic, Slope Top, LH 05630430 Cabinet Accessories- Flat Top Control Door 056389489 Control Door with Lock 0632570 Frame, Control Door 06232309 Discharge Grille 06232350 PTAC; MQE, 007-06 MQR, 007-05 Vintage D Rev. N 0/5 RPL 57099 /Page 22

Critical Daikin Applied OEM s Are What Your HVAC Unit Needs! McQuay Incremental MQE, MQR 007, 009 Vintage D Critical Components Unit Sizes Voltage Compressor Compressor 007 5/60/ 0665390 Compressor 007 208/230/60/ 06653902 Compressor 007 265/60/ 06653903 Compressor, Sea Coast 007 5/60/ 062242927 Compressor, Sea Coast 007 208/230/60/ 062242925 Compressor, Sea Coast 007 265/60/ 062242928 Compressor 009 5/60/ 06086003 Compressor 009 208/230/60/ 06086002 Compressor 009 265/60/ 0608600 Compressor, Sea Coast 009 5/60/ 062242929 Compressor, Sea Coast 009 208/230/60/ 062242924 Compressor, Sea Coast 009 265/60/ 062242923 Motor, Indoor Motor, /6 HP 007, 009 5/60/ 06085370 Motor, /6 HP 007, 009 208/60/ 060853702 Motor, /6 HP 007, 009 230/60/ 060853703 Motor, /6 HP 007, 009 265/60/ 060853704 Motor, Outdoor Motor, /8 HP 007, 009 5/60/ 064503 Motor, /8 HP 007, 009 208/230/60/ 06450 Motor, /8 HP 007, 009 265/60/ 064502 Motor, Sea Coast, /8 HP 007, 009 5/60/ 06224283 Motor, Sea Coast, /8 HP 007, 009 208/230/60/ 0622428 Motor, Sea Coast, /8 HP 007, 009 265/60/ 06224282 Wheel Wheel- Blower, Indoor 007, 009 N/A 06064200 Fan Prop, Outdoor 007, 009 N/A 063830 Call Your Local Daikin Applied s Distributor For All Your s Needs. To Locate A Distributor, Go To www.daikinapplied.com or Call -800-37PARTS 57099 Rev. N 0/205 CPL Page of 2

Critical Daikin Applied OEM s Are What Your HVAC Unit Needs! McQuay Incremental MQE 02, 05, 06 MQR 02, 05 Vintage D Critical Components Unit Sizes Voltage Compressor Compressor 02 208/230/60/ 06090780 Compressor 02 265/60/ 060907802 Compressor 05, 06 208/230/60/ 0604340 Compressor 05 265/60/ 06043402 Compressor, Sea Coast 02 208/230/60/ 06224296 Compressor, Sea Coast 02 265/60/ 06224297 Compressor, Sea Coast 05 208/230/60/ 062242920 Compressor 06 208/230/60/ 06654030 Motor, Indoor Motor, /20 HP 02, 05, 06 208/60/ 0695802 Motor, /20 HP 02, 05, 06 230/60/ 0695803 Motor, /20 HP 02, 05 265/60/ 0695804 Motor, Outdoor Motor, /8 HP 02, 05, 06 208/230/60/ 06450 Motor, /8 HP 02, 05 265/60/ 064502 Motor, Sea Coast, /8 HP 02, 05 208/230/60/ 0622428 Motor, Sea Coast, /8 HP 02, 05 265/60/ 06224282 Wheel Wheel- Blower, LH 02, 05, 06 N/A 06654050 Wheel- Blower, RH 02, 05, 06 N/A 066540502 Fan Prop, Outdoor 02, 05, 06 N/A 063830 Call Your Local Daikin Applied s Distributor For All Your s Needs. To Locate A Distributor, Go To www.daikinapplied.com or Call -800-37PARTS 57099 Rev. N 0/205 CPL Page 2 of 2