PHOTOS. December 8, 2017

Similar documents
FIRE ALARM: BY OTHERS, IF REQUIRED.

FIRE ALARM: BY OTHERS, IF REQUIRED.

Ho-Chunk Gaming THUNDERBIRD ENGINEERING, INC. MILWAUKEE: (414) MADISON: (608)


M001. Revenue Services ISSUED FOR CONSTRUCTION SEPTEMBER. 2, East State Parkway Schaumburg, Illinois Do Not Scale Drawings

Electrical System (N) PANELBOARD "L1" VOLTAGE: 208/120 A, 3P :MAIN C/B PHASE: 3 A :BUSSING WIRE: 4 :MOUNTING

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- ELECTRICAL

SINGLE CONVENIENCE OUTLET, WALL MOUNTED RECESSED +18" AFF

ELECTRICAL SYSTEMS ASSESSMENT Hanover High School

The following narrative outlines a conceptual electrical Scope of Work for converting the Phase 2 TRW Building to an Exhibition Hall.

Building Division 201 SE 3 rd STREET (Second Floor) OCALA, FL Phone: (352) BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS

Lindsay Frederick. Lighting + Electrical. Ron Dodson Faculty Advisor. Native American Cultural Center Arizona. Technical Report 2

GARCIA GALUSKA DESOUSA Consulting Engineers

TOM BURNS, PLANNING DIRECTOR

.4 Do complete installation in accordance with latest Electrical Bulletins of the local inspection authority.


PROJECT NO. CWA SEPTEMBER 24, 2014 ADDENDUM NO. 6 BESSEMER RECREATION & WELLNESS CENTER

CITY OF HEALDSBURG SENIOR CENTER IMPROVEMENT PROJECT

Electrical Design Guidelines Table of Contents

COMMON WORK RESULTS FOR ELECTRICAL: Basic Electrical Materials Methods

DEMOLITION GENERAL NOTES As-built conditions have been determined from Record Drawings (if they exist), field investigations (accessible areas and

ELECTRICAL SYMBOLS AND ABBREVIATIONS NOT ALL SYMBOLS, DEVICES OR ABBREVIATIONS MAY BE USED

SECTION EXTERIOR LIGHTING

HMC ARCHITECTS 2495 Natomas Park Drive, Studio 100 Sacramento, California ADDENDUM NO. 3

Photovoltaic (Solar) Array Installation Guide

SANTA CLARA COUNTY Winchester Blvd., Los Gatos, CA (408) (408) (fax)

Leviton Combination Switch And Tamper Resistant Outlet Wiring Diagram

FRONT END ENCLOSURE (FEE) - ROOM DATA SHEET

Division 26 ELECTRICAL TABLE OF CONTENTS

SECTION (16140) - WIRING DEVICES

DONALD H. BERG, ARCHITECT

CITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU FIRE ALARM / ELECTRICAL FIRE PLAN REVIEW CHECKLIST

LIGHT LEVEL REQUIREMENTS MINIMUM ACCEPTABLE FOOT CANDLES

SECTION LOW VOLTAGE LIGHTING CONTROLS

SECTION LIGHTING CONTROLS

SECTION PANELBOARDS. A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section.

Element D Services Electrical

Town of Cicero Local Code Amendments

ELECTRICAL DESIGN GUIDELINES SECTION GUIDELINE SPECIFICATIONS-DUVAL COUNTY PUBLIC SCHOOL

DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES

TABLE LIGHTING POWER DENSITIES FOR BUILDING EXTERIORS ASHRAE Uncovered Parking Areas. Building Grounds. Walkways 10 feet wide or greater

INDEX. Page 2 to 7 Electrical Specifications. Page 8 Electrical Schemes: Basement Plan. Page 9 Electrical Schemes: First Floor Plan

Renovate MCRC Facilities Great Lakes, IL

A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

Chapter 1 General... 5

CITY OF LOS ANGELES LARUCP ELECTRICAL PLAN CHECK LIST

SECTION LIGHTING CONTROL DEVICES

TABLE OF CONTENTS CHAPTER 1 GENERAL RULES CHAPTER 2 WIRING AND PROTECTION... 51

A. Shop Drawing submittals shall include, but not be limited to, the following:

Student Services & Classroom Addition. A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

A. This Section includes the following lighting control devices:

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

DIVISION 16 ELECTRICAL

A. Furnish and install wiring devices and plates as specified herein and as shown on the Drawings.

Spring Test 6 due 04/26/2013

DIVISION 28 ELECTRONIC SAFETY AND SECURITY

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Corbin Building. Technical Assignment 2. Matthew Trethaway Lighting/ Electrical AE 481W 10/26/2011 Advisor: Ted Dannerth

IN2 Lighting Control Devices

Princeton Joint Unified School District Invitation for Bid Installation of District-Wide Lighting Occupancy Sensors

2 Main Office Building BLDG-955A Building Purpose Building Area Administration offices. Training room 7,610 SF Inspection Date August 16, 2016 Inspect

B. Shop Drawings: List of legends and description of materials and process used for premarking wall plates.

A. Furnish and install luminaires, lamps, ballasts and in-line fuses as herein specified and shown on the Drawings.

SECTION LIGHTING CONTROL DEVICES AND CONTROL PANELS

ESTIMATE SET-UP PACKAGE BID SCHEDULE ENTRY AND MAINTENANCE

Architect s Project Number of 12 Fire Alarm/Smoke Detection Systems District Master Specs 2013 Edition

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL

The following information shall become and form part of the contract documents.

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

L04 X01 X03 X01 R21A R21A F09 L27 R18 R16A R18 R21A KING 107 F09 F09 L27 D03A Z-38 KING 109 R21A R18 R16A R18 R21A F09 F09 X03 L27 F09 R21A R18 R18

BUILDING 751-CEH-OFFICE RENOVATION- OVERALL ROOM DATA SHEET

APPENDIX - L INTERNATIONAL RESIDENTIAL CODE ELECTRICAL

Related Sections: TBD. Effective Date: January 1, 2016

Technical II Report Electrical Systems

F. GENERAL REQUIREMENTS Electrical Design Criteria 2009 Edition 11/23/2009 School District Palm Beach County Page-1 of 17

Informational Bulletin on Mobile office Units Prepared by Mark Hilbert May 17, 2017

S AGE E NGINEERING A SSOCIATES, LLP

ELECTRICAL Seminar. B A L A Consulting Engineers, Inc. Edward J. Lynch, PE Vice President, Electrical Department Manager.

F. GENERAL REQUIREMENTS Electrical Design Criteria 2006 Edition 4/3/06 School District Palm Beach County Page-1 of 15

ELECTRICAL REQUIREMENTS FOR HEALTH CARE FACILITIES

TABLE OF CONTENTS CHAPTER 2 WIRING AND PROTECTION CHAPTER 1 GENERAL RULES... 19

SECTION PANELBOARDS Painting Wire and Cable Overcurrent Protective Devices.

Appendix B. Facilities Assessment Report

CHAPTER 20 SERVICE EQUIPMENT

RAZOR RZR SERIES DIE CAST ALUMINUM LED EXIT SIGNS INSTALLATION AND OPERATING INSTRUCTIONS IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

Port of Portland Conveying Equipment Guidelines

CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT ELECTRICAL POWER AND TRANSMISSION INSTALLERS. Test Code: 5922 Version: 01

CITY OF FARMINGTON 800 Municipal Drive Farmington, NM (505) Fax (505)

PART GENERAL 1.01 SECTION INCLUDES

CARD ACCESS CONTROL SYSTEM

SPACE TYPE: JUDICIAL CHAMBER

MEDIUM, LOW AND CONTROL VOLTAGE CABLES

The Owner will provide the QEI inspection and certification services.

SOUTHVIEW MEDICAL CENTER

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

9 E. Scarborough Park Concession Stand and Restroom And / Or Lake Kirby Park Softball Fields Restroom Addition

Project No Belleville Fire Hall/Headquarters and Emergency Operations Centre Section Belleville, Ontario Page 1 of 10

Marco Dwyer. Yefeng Yan. Osei Salmon MECHANICAL SYSTEMS

Catalog Number. Notes. Type. FST Snap on frosted, diffuse L/LENS No diffuser

CHAPTER 14 ELECTRICAL CODE

Transcription:

PHOTOS City of Santa Monica Camera Obscura Exterior Lighting Upgrades 1450 Ocean Avenue Santa Monica, CA 90401 December 8, 2017 Kitchell CEM

Camera Obscura Building Exterior Lighting Upgrades December 8, 2017 Camera Obscura Exterior Lighting Upgrades Photo 1 - Site Plan Photo 2 - Front Entrance 1 P a g e

Camera Obscura Building Exterior Lighting Upgrades December 8, 2017 Photo 3 Front Entrance Lights (to be Replaced) Photo 4 Front 2 P a g e

Camera Obscura Building Exterior Lighting Upgrades December 8, 2017 Photo 5 Southeast Side Photo 6 Southeast Corner (Restrooms) 3 P a g e

Camera Obscura Building Exterior Lighting Upgrades December 8, 2017 Photo 7 Restroom Lights (to be Replaced) Photo 8 Southwest Courtyard (New Lights to be Provided Under Eaves) 4 P a g e

Camera Obscura Building Exterior Lighting Upgrades December 8, 2017 Photo 9 Southwest Courtyard (Lights to be Replaced) Photo 10 West Side 5 P a g e

Camera Obscura Building Exterior Lighting Upgrades December 8, 2017 Photo 11 West Side (New Light to be Provided Under Eave) Photo 12 West Side (New Lights to be Provided Under Eave) 6 P a g e

Camera Obscura Building Exterior Lighting Upgrades December 8, 2017 Photo 13 Northwest Corner (New Lights to be Provided Under Eave) Photo 14 Northwest Corner (Light to be Replaced) 7 P a g e

Camera Obscura Building Exterior Lighting Upgrades December 8, 2017 Photo 15 North Side Photo 16 North Side (New Lights to be Provided Under Eave, Existing Light Replaced) 8 P a g e

Camera Obscura Building Exterior Lighting Upgrades December 8, 2017 Photo 17 Northwest Entrance Photo 18 Northwest Entrance (Light to be Replaced) 9 P a g e

TITLE OF PROJECT: CITY OF SANTA MONICA - CAMERA OBSCURA - EXTERIOR LIGHTING DRAWING NO: 6926 VICINITY MAP NTS GOVERNING CODES A. 2016 CALIFORNIA CODE OF REGULATIONS TITLE 19, PUBLIC SAFETY, STATE FIRE MARSHAL REGULATIONS. B. 2016 CALIFORNIA BUILDING STANDARDS ADMINISTRATIVE CODE - CALIFORNIA CODE OF REGULATIONS (C.C.R) TITLE 24, PART 1. C. 2016 CALIFORNIA BUILDING CODE (CBC) C.C.R., TITLE 24, PART 2, VOLUME 1 & 2 (2015 INTERNATIONAL BUILDING CODE, VOL. 1-3 WITH 2016 CALIFORNIA AMENDMENTS). D. 2016 CALIFORNIA ELECTRICAL CODE (CEC), C.C.R., TITLE 24, PART 3 (2014 NATIONAL ELECTRICAL CODE WITH 2016 CALIFORNIA AMENDMENTS). E. 2016 CALIFORNIA MECHANICAL CODE (CMC), C.C.R., TITLE 24, PART 4 (2015 UNIFORM MECHANICAL CODE WITH 2016 CALIFORNIA AMENDMENTS). F. 2016 CALIFORNIA PLUMBING CODE (CPC), C.C.R., TITLE 24, PART 5 (2015 UNIFORM PLUMBING CODE WITH 2016 CALIFORNIA AMENDMENTS). G. 2016 CALIFORNIA ENERGY CODE, C.C.R., TITLE 24, PART 6. H. CALIFORNIA CODE OF REGULATIONS TITLE 8 BY CAL/OSHA OF DEPARTMENT OF INDUSTRIAL RELATIONS I. 2016 CALIFORNIA FIRE CODE (CFC), C.C.R., TITLE 24, PART 9 (2015 INTERNATIONAL FIRE CODE WITH CALIFORNIA AMENDMENTS). J. 2016 GREEN BUILDING STANDARDS CODE (CALGREEN), C.C.R., TITLE 24, PART 11. K. 2016 CALIFORNIA REFERENCED STANDARDS CODE, C.C.R., TITLE 24, PART 12. L. 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN, AMERICANS WITH DISABILITIES ACT. CITY OF SANTA MONICA CAMERA OBSCURA EXTERIOR LIGHTING UPGRADES 1450 OCEAN AVE SANTA MONICA, CA 90401 75% CONSTRUCTION DOCUMENTS LOCATION MAP NTS PROJECT SCOPE THE SCOPE OF WORK CONSISTS OF THE REPLACEMENT AND ADDITION OF EXTERIOR LIGHTING FIXTURES AROUND THE PERIMETER OF THE BUILDING. WORK INCLUDES ASSOCIATED CONTROLS TO COMPLY WITH TITLE 24 REQUIREMENTS. N TRUE NORTH GENERAL G001 CONSULTANT KITCHELL CEM 2450 VENTURE OAKS WAY SUITE 500 SACRAMENTO, CA 9533 PHONE: 916.648.9700 FAX: 916.648.6534 CONTACT: MILUTIN BACKOVICH EMAIL: MBACKOVICH@KITCHELL.COM OWNER WILLIAM CLERK ARCHITECTURAL ASSOCIATE CITY OF SANTA MONICA ARCHITECTURE SERVICES DIVISION 1437 FOURTH ST. SUITE 300 SANTA MONICA, CA 90401 (310) 458-2205 EXT.5288 O (310) 429-6555 C (310) 399-1541 F COVER SHEET SHEET INDEX ELECTRICAL E001 ELECTRICAL ABBREVIATIONS, SYMBOLS, & NOTES ED100 SITE LIGHTING DEMOLITION PLAN E100 SITE LIGHTING PLAN E300 ELECTRICAL DETAIL AND SCHEDULE E301 PHOTOMETRIC STUDY E800 LIGHT STUDY RENDERING E801 LIGHT STUDY RENDERING (2) Capital Expenditure Managers 2450 Venture Oaks Way Suite 500 Sacramento, CA. 95833 (916) 648-9700 DRAWN BY: SHEET TITLE SCALE ARCHITECTURAL SERVICES 1437 4TH STREET, SUITE 300 SANTA MONICA, CA 90401 TEL. 310-458-2205 FAX. 310-399-1541 architecture@smgov.net CONSULTANTS SUBMITTED BY: Milutin Backovich, Licensed Engineer APPROVED BY: Miriam Mulder, City Architect CITY OF SANTA MONICA DEPARTMENT OF PUBLIC WORKS PROJECT STATUS: No. Description Date NOT FOR CONSTRUCTION 75% CONSTRUCTION DOCUMENTS PROJECT City of Santa Monica CAMERA OBSCURA EXTERIOR LIGHTING SP2430 SP-FILE NO: 2430 DRAWING NO: 6926 COVER SHEET G001 11/28/17 AS 12" = 1'-0" 2/20/2018 10:31:08 AM

TITLE OF PROJECT: CITY OF SANTA MONICA - CAMERA OBSCURA - EXTERIOR LIGHTING DRAWING NO: 6926 ELECTRICAL ABBREVIATIONS SYMBOL AC AFF AFG ACCPNL AWG AIC A AF AT ATS BIL BFG BPT CAB CLG CKT CB CCTV CX COMM C CO CU DF EWC EMT EM ENCL (ER) FA FLEX FLUOR FLA FU F GALV GRD/GND GFI GFR HZ HID HPS HP JB KA KV KVA KW KWH KEC LT LTG LRA LCL LV MFR MATV MOM M MC MTD MTG DESCRIPTION ABOVE CEILING ABOVE FINISHED FLOOR ABOVE FINISHED GRADE ACCESS PANEL AMERICAN WIRE GAUGE AMP INTERRUPTING CURRENT AMPERE (AMPS) AMPS-FRAME AMPS-TRIP AUTOMATIC TRANSFER SWITCH BASIC IMPULSE LEVEL BELOW FINISHED GRADE BY-PASS TIMER CABINET CEILING CENTERLINE CIRCUIT CIRCUIT BREAKER CLOSED CIRCUIT TELEVISION COAXIAL CABLE COMMUNICATION CONDUIT CONDUIT ONLY COPPER DRINKING FOUNTAIN ELECTRIC WATER COOLER ELECTRICAL METALLIC TUBING CONDUIT EMERGENCY ENCLOSURE EXISTING RELOCATE FIRE ALARM FLEXIBLE METAL CONDUIT FLUORESCENT FULL LOAD AMPS FUSE FUSED GALVANIZED GROUND GROUND FAULT INTERRUPTER GROUND FAULT RELAY HERTZ HIGH INTENSITY DISCHARGE HIGH PRESSURE SODIUM HORSEPOWER JUNCTION BOX KILOAMPERES KILOVOLT KILOVOLT AMPERES KILOWATT KILOWATT HOURS KITCHEN EQUIPMENT CONTRACTOR LIGHT LIGHTING LOCKED ROTOR AMPS LONG CONTINUOUS LOAD LOW VOLTAGE MANUFACTURER MASTER ANTENNA TELEVISION MOMENTARY MOTOR MOTOR CONTROLLER MOUNTED MOUNTING NL NIGHT LIGHT NF NON-FUSED NOR NORMAL NC NORMALLY CLOSED NO NORMALLY OPEN/NUMBER # NUMBER PNL PH POC P PVC PWR PF PRI PA PB REFRIG (R) (RR) RVS RMC RMS PANEL PHASE POINT OF CONNECTION POLE POLYVINYL CHLORIDE DUCT POWER POWER FACTOR PRIMARY PUBLIC ADDRESS PULL BOX REFRIGERATOR REMOVE REMOVE AND RELOCATE REVERSE RIGID METALLIC CONDUIT ROOT MEAN SQUARE SYMBOL SHT SPST SN SSC SW SWBD SYM TTB TTC KCMIL MCM TC XFMR TP TPS 2SP UG UPS V VA WHM WP W DESCRIPTION SHEET SINGLE POLE SINGLE THROW SOLID NEUTRAL SOUND SYSTEM CABINET SWITCH SWITCHBOARD SYMMETRICAL TELEPHONE TERMINAL BOARD TELEPHONE TERMINAL CABINET THOUSAND CIRCULAR MILS THOUSAND CIRCULAR MILS TIMECLOCK TRANSFORMER TWISTED PAIR TWISTED PAIR SHIELDED TWO SPEED UNDERGROUND UNINTERRUPTIBLE POWER SYSTEM VOLT VOLTAMPERES WATT HOUR METER WEATHERPROOF WIRE/WATTS POWER SYMBOLS SYMBOL PP-1 J M G OS DESCRIPTION MAIN SWITCHBOARD, DISTRIBUTION BOARD OR MOTOR CONTROL CENTER. PANELBOARD DUPLEX OUTLET, +18" UON. DUPLEX OUTLET, SPLIT WIRED. DUPLEX OUTLET, MOUNTED ABOVE COUNTER, +42", +46" WHERE BACKSPLASH OCCURS, UON. DUPLEX OUTLET WITH GROUND FAULT INTERRUPTER. QUADRUPLEX OUTLET, +18" UON. SINGLE OUTLET, +18" UON. QUADRUPLEX OUTLEX, MOUNTED IN FLUSH FLOOR BOX. DISCONNECT SWITCH JUNCTION BOX, 4' SQUARE UON FLOOR MOUNTED. JUNCTION BOX, 4" SQUARE UON WALL MOUNTED. ELECTRIC MOTOR BUZZER PHOTOELECTRIC SWITCH SWITCH, TOGGLE, SINGLE POLE, SINGLE THROW SUBSCRIPT MODIFIERS: 1,2 SWITCHING CIRCUIT D DR K P T DIMMER DOOR KEY OPERATED PILOT LIGHTED TIMER 3 THREE WAY 4 FOUR WAY WALL SWITCH OCCUPANCY SENSOR. CEILING MOUNTED OCCUPANCY SENSOR. THERMOSTAT METER (WATT HOUR) LIGHTING SYMBOLS SYMBOL X PP-1, 2 A DESCRIPTION FLUORESCENT FIXTURE, SURFACE OR PENDANT MOUNTED. FLUORESCENT STRIPLIGHT FIXTURE, SURFACE OR PENDANT MOUNTED. OUTDOOR LIGHT FIXTURE, MOUNTED UNDER EAVE LUMINAIRE FIXTURE, RECESSED IN CEILING LUMINAIRE FIXTURE, SURFACE OR PENDANT MOUNTED. LUMINAIRE WALL WASHER FIXTURE, RECESSED IN CEILING. EXIT FIXTURE EMERGENCY BATTERY PACK WITH TWO FLOOR HEADS LIGHTING FIXTURE TYPE SPOT LIGHT LIGHTING SWITCHING CIRCUIT, PANEL BOARD, CIRCUIT NUMBER. MOTION SENSOR, HUBBELL LIGHTOWL LO-IRWVRP-LWO. SUBSCRIPT INDICATES FIXTURES CONTROLLED. DATA SYMBOLS SYMBOL MM V M S TV F F K D TV DESCRIPTION GENERAL NOTES: TELEPHONE TERMINAL BOARD, 4' x 8' x 3/4" UON. WALL TELEPHONE OUTLET, +18" UON. TELEPHONE/DATA OUTLET, +18" UON, PROVIDE 4" x 4" J- BOX W/ SINGLE GANG RING. PROVIDE 4 CABLE DROPS AT EACH OUTLET UON. MULTIMEDIA OUTLET, +18" UON. VOLUME CONTROL, +42" AFF. MICROPHONE OUTLET, +42" AFF. WALL SPEAKER CEILING SPEAKER COAXIAL CABLE JACK, +7' - 6" AFF UON. PROVIDE 4" x 4" J-BOX WITH SINGLE GANG RING. FIRE ALARM HORN FIRE ALARM HORN AND STROBE SMOKE SENSING FIRE DETECTOR KEYPAD OR KEY CARD, +42" AFF. DOOR CONTACT WALL MOUNTED MONITOR ELECTRICAL SYMBOLS MATCH LINE VIEW REFERENCE DETAIL SECTION EQUIPMENT TAG SYMBOL 1 XXXX TYM SEQ 1 / E101A 1 / E101B DESCRIPTION 1 XXXX DESCRIPTION VIEW NUMBER / SHEET NUMBER SHADED PORTION IS SIDE CONSIDERED VIEW NUMBER SHEET NUMBER SECTION IDENTIFIER SHEET NUMBER MECHANICAL EQUIPMENT: SEE MECHANICAL DRAWINGS FOR EQUIPMENT INFORMATION. 1. PROVIDE AND LOCATE OUTLETS, WIRING AND CONTROLS, AS INDICATED OR REQUIRED FOR EQUIPMENT FURNISHED UNDER OTHER SECTIONS OR CONTRACTS PER EQUIPMENT SUPPLIERS REQUIREMENTS. CONNECT TO ALL EQUIPMENT AND ASSOCIATED CONTROLS, UNLESS OTHERWISE DIRECTED. VERIFY LOCATIONS, RATINGS, VOLTAGES, CONTROL WIRING, CONTROL DEVICES TO BE FURNISHED AND/OR INSTALLED WITH TRADE DRAWINGS AND SPECIFICATIONS. REFER TO EQUIPMENT OR SYSTEM SPECIFICATIONS REQUIRING ELECTRICAL WORK TO DETERMINE SCOPE OF WORK REQUIRED. 2. DO NOT CUT OR IN ANY WAY MODIFY ANY GIRT, BEAM OR OTHER STRUCTURAL MEMBER UNLESS SPECIFICALLY PREAPPROVED IN WRITING BY THE STRUCTURAL ENGINEER. 3. ALL NEW RACEWAYS AND WIRING SHALL BE CONCEALED IN WALLS AND CEILINGS UNLESS OTHERWISE INDICATED. PATCH AND REPAIR ANY WALLS AND CEILINGS DAMAGED BY THE INSTALLATION OF THE NEW RACEWAYS, WIRING AND DEVICES. 4. AN ELECTRICAL PERMIT IS REQUIRED BEFORE THE START OF ANY ELECTRICAL WORK. CONTRACTOR SHALL OBTAIN PERMIT AND PAY ALL ASSOCIATED FEES. 5. ALL ELECTRICAL WORK SHALL BE PERFORMED BY A C-10 LICENSED CONTRACTOR IN THE STATE OF CALIFORNIA. 6. ALL OUTDOOR ELECTRICAL EQUIPMENT AND ENCLOSURES SHALL BE NEMA 3R RATED. RACEWAYS SYMBOL CONDUIT TURNED UP CONDUIT TURNED DOWN FLEXIBLE CONDUIT 7. EXISTING LIGHT FIXTURES AND PANELBOARDS SHALL BE SALVAGED, REINSTALLED, AND REUSED FOR NEW WORK. SEE ARCHITECTURAL DEMOLITION PLANS. CONDUIT HOMERUN, CONTINUOUS RUN TO PANEL OR EQUIPMENT CABINET CONDUIT HOMERUN CONCEALED UNDER SLAB OR UNDERGROUND CONNECT TO GROUNDING ELECTRODE GROUNDING ROD Capital Expenditure Managers 2450 Venture Oaks Way Suite 500 Sacramento, CA. 95833 (916) 648-9700 DRAWN BY: SHEET TITLE SCALE ARCHITECTURAL SERVICES 1437 4TH STREET, SUITE 300 SANTA MONICA, CA 90401 TEL. 310-458-2205 FAX. 310-399-1541 architecture@smgov.net CONSULTANTS SUBMITTED BY: Milutin Backovich, Licensed Engineer APPROVED BY: Miriam Mulder, City Architect CITY OF SANTA MONICA DEPARTMENT OF PUBLIC WORKS PROJECT STATUS: No. Description Date NOT FOR CONSTRUCTION 75% CONSTRUCTION DOCUMENTS PROJECT City of Santa Monica CAMERA OBSCURA EXTERIOR LIGHTING SP2430 SP-FILE NO: 2430 DRAWING NO: 6926 AS ELECTRICAL ABBREVIATIONS, SYMBOLS, & NOTES E001 11/28/17 1/8" = 1'-0" 2/20/2018 10:30:51 AM

TITLE OF PROJECT: CITY OF SANTA MONICA - CAMERA OBSCURA - EXTERIOR LIGHTING DRAWING NO: 6926 1 3 1 SITE LIGHTING PLAN - DEMOLITION 1/8" = 1'-0" 2 SB (E) PANEL A (E) MAIN SWITCHBOARD WITH INTEGRAL PANEL OCEAN AVENUE 4 PALISADES PARK SIDEWALK/ PARKWAY 6 5 4 GENERAL NOTE 1. FOR (E) FIXTURES THAT ARE TO BE DEMOLISHED, (E) CONDUCTORS CAN BE REMOVED BACK TO SOURCE TO BACK TO ANY (E) FIXTURES THAT ARE TO REMAIN. PROVIDE CIRCUIT CONTINUITY TO ALL FIXTURES THAT ARE TO REMAIN AND THAT ARE NOT A PART OF THIS SCOPE OF WORK. (N) FIXTURES WILL HAVE (N) CONDUCTORS PROVIDED. (E) CONDUIT CAN BE-REUSED IF APPROPRIATELY SIZED. 1 2 3 4 5 6 KEYNOTES DEMOLISH (E) CEILING MOUNTED FIXTURE. CAP (E) CONDUCTORS IN (E) JUNCTION BOX. PROVIDE A GASKETED, WEATHERPROOF COVER ON (E) JUNCTION BOX. DEMOLISH (E) CEILING MOUNTED FIXTURE. (E) CONDUCTORS AND JUNCTION BOX TO REMAIN FOR USE WITH (N) FIXTURE. DEMOLISH (E) CEILING MOUNTED FIXTURE. (E) CONDUCTORS AND JUNCTION BOX TO REMAIN FOR USE WITH (N) FIXTURE. DEMOLISH (E) CEILING MOUNTED FIXTURES. (E) CONDUCTORS AND JUNCTION BOXES TO REMAIN FOR USE WITH (N) FIXTURES. DEMOLISH (E) CEILING MOUNTED FIXTURES. (E) CONDUCTORS AND JUNCTION BOXES TO REMAIN FOR USE WITH (N) FIXTURES. CAP ANY UNUSED CONDUCTORS AND PROVIDE A GASKETED WEATHERPROOF COVER ON ANY UNUSED JUNCTION BOXES. DEMOLISH (E) TIME CLOCKS. (E) CIRCUITS WILL BE RECONNECTED TO (N) LIGHTING CONTROL PANEL. 4 N Capital Expenditure Managers 2450 Venture Oaks Way Suite 500 Sacramento, CA. 95833 (916) 648-9700 DRAWN BY: SHEET TITLE SCALE ARCHITECTURAL SERVICES 1437 4TH STREET, SUITE 300 SANTA MONICA, CA 90401 TEL. 310-458-2205 FAX. 310-399-1541 architecture@smgov.net CONSULTANTS SUBMITTED BY: Milutin Backovich, Licensed Engineer APPROVED BY: Miriam Mulder, City Architect CITY OF SANTA MONICA DEPARTMENT OF PUBLIC WORKS No. Description Date NOT FOR CONSTRUCTION PROJECT STATUS: 75% CONSTRUCTION DOCUMENTS PROJECT City of Santa Monica CAMERA OBSCURA EXTERIOR LIGHTING SP2430 SP-FILE NO: 2430 DRAWING NO: 6926 AS SITE LIGHTING DEMOLITION PLAN ED100 11/28/17 As indicated 2/20/2018 10:31:04 AM

TITLE OF PROJECT: CITY OF SANTA MONICA - CAMERA OBSCURA - EXTERIOR LIGHTING DRAWING NO: 6926 G 1 SITE LIGHTING PLAN 1/8" = 1'-0" G G G G H H H F F F F F 3 F 2 (E) PANEL A (E) MAIN SWITCHBOARD WITH INTEGRAL PANEL 3 OCEAN AVENUE F1 A F1 A A F1 F1 A A A (E) TIME CLOCKS (E) PANEL B PALISADES PARK SIDEWALK/ PARKWAY E E E E E LIGHTING FIXTURE SCHEDULE TAG DESCRIPTION MANUFACTURER MODEL NUMBER WATTS LAMP F1 VANDAL RESISTANT LED CANOPY LIGHT WITH DROP LENS RAB LIGHTING VAN LED 20 D10 20 LED VANDAL RESISTANT LED CANOPY LIGHT WITH DROP LENS FC LIGHTING FCW3062 120V LED4K 52W SL 52 LED 1 D B D D D B B C C C N 1 2 3 KEYNOTES MOUNT FIXTURE UNDER LOWER EAVE. (N) LIGHTING CONTROL PANEL - HUBBELL CX-08. SEE SINGLE LINE DIAGRAM ON E300. Capital Expenditure Managers 2450 Venture Oaks Way Suite 500 Sacramento, CA. 95833 (916) 648-9700 DRAWN BY: SHEET TITLE SCALE ARCHITECTURAL SERVICES 1437 4TH STREET, SUITE 300 SANTA MONICA, CA 90401 TEL. 310-458-2205 FAX. 310-399-1541 architecture@smgov.net CONSULTANTS SUBMITTED BY: Milutin Backovich, Licensed Engineer APPROVED BY: Miriam Mulder, City Architect CITY OF SANTA MONICA DEPARTMENT OF PUBLIC WORKS No. Description Date NOT FOR CONSTRUCTION PROJECT STATUS: 75% CONSTRUCTION DOCUMENTS PROJECT City of Santa Monica CAMERA OBSCURA EXTERIOR LIGHTING SP2430 SP-FILE NO: 2430 DRAWING NO: 6926 SITE LIGHTING PLAN E100 11/28/17 AS As indicated 2/20/2018 10:30:54 AM

TITLE OF PROJECT: CITY OF SANTA MONICA - CAMERA OBSCURA - EXTERIOR LIGHTING DRAWING NO: 6926 3 Cx8 RELAY PANEL NTS 400A/2P 100A/2P PANEL A (E) MAIN SWITCHBOARD MSB - 400A, 120/240V, 1 PHASE, 3 WIRE (E) MAIN SWITCHBOARD PANEL - 120/240V, 1 PHASE, 3 WIRE, 600A 100A/2P PANEL B (E) PANELS 60A/2P PANEL C 1 SINGLE LINE DIAGRAM NTS TO (E) LOADS (N) 20A/1P (N) LIGHT FIXTURES (N) 20A/1P 2 CX-4-8-DOOR NTS (N) 20A/1P (N) LIGHTING CONTROL PANEL (N) 2#12 + 1#12 GND IN 3/4"C PROVIDE 2#10+1#10 GND IN 3/4" CONDUIT TO EACH LIGHT FIXTURE, TYPICAL Capital Expenditure Managers 2450 Venture Oaks Way Suite 500 Sacramento, CA. 95833 (916) 648-9700 DRAWN BY: SHEET TITLE SCALE ARCHITECTURAL SERVICES 1437 4TH STREET, SUITE 300 SANTA MONICA, CA 90401 TEL. 310-458-2205 FAX. 310-399-1541 architecture@smgov.net CONSULTANTS SUBMITTED BY: Milutin Backovich, Licensed Engineer APPROVED BY: Miriam Mulder, City Architect CITY OF SANTA MONICA DEPARTMENT OF PUBLIC WORKS No. Description Date NOT FOR CONSTRUCTION PROJECT STATUS: 75% CONSTRUCTION DOCUMENTS PROJECT City of Santa Monica CAMERA OBSCURA EXTERIOR LIGHTING SP2430 SP-FILE NO: 2430 DRAWING NO: 6926 AS ELECTRICAL DETAIL AND SCHEDULE E300 11/28/17 As indicated 2/20/2018 10:30:58 AM

TITLE OF PROJECT: CITY OF SANTA MONICA - CAMERA OBSCURA - EXTERIOR LIGHTING DRAWING NO: 6926 Capital Expenditure Managers 2450 Venture Oaks Way Suite 500 Sacramento, CA. 95833 (916) 648-9700 DRAWN BY: SHEET TITLE SCALE ARCHITECTURAL SERVICES 1437 4TH STREET, SUITE 300 SANTA MONICA, CA 90401 TEL. 310-458-2205 FAX. 310-399-1541 architecture@smgov.net CONSULTANTS SUBMITTED BY: Milutin Backovich, Licensed Engineer APPROVED BY: Miriam Mulder, City Architect CITY OF SANTA MONICA DEPARTMENT OF PUBLIC WORKS No. Description Date NOT FOR CONSTRUCTION PROJECT STATUS: 75% CONSTRUCTION DOCUMENTS PROJECT City of Santa Monica CAMERA OBSCURA EXTERIOR LIGHTING SP2430 SP-FILE NO: 2430 DRAWING NO: 6926 PHOTOMETRIC STUDY E301 11/28/17 AS 2/20/2018 10:30:59 AM

TITLE OF PROJECT: CITY OF SANTA MONICA - CAMERA OBSCURA - EXTERIOR LIGHTING DRAWING NO: 6926 WEST ELEVATION EAST ELEVATION SOUTH ELEVATION NORTH ELEVATION Capital Expenditure Managers 2450 Venture Oaks Way Suite 500 Sacramento, CA. 95833 (916) 648-9700 DRAWN BY: SHEET TITLE SCALE ARCHITECTURAL SERVICES 1437 4TH STREET, SUITE 300 SANTA MONICA, CA 90401 TEL. 310-458-2205 FAX. 310-399-1541 architecture@smgov.net CONSULTANTS SUBMITTED BY: Milutin Backovich, Licensed Engineer APPROVED BY: Miriam Mulder, City Architect CITY OF SANTA MONICA DEPARTMENT OF PUBLIC WORKS No. Description Date NOT FOR CONSTRUCTION PROJECT STATUS: 75% CONSTRUCTION DOCUMENTS PROJECT City of Santa Monica CAMERA OBSCURA EXTERIOR LIGHTING SP2430 SP-FILE NO: 2430 DRAWING NO: 6926 AS LIGHT STUDY RENDERING E800 11/28/17 2/20/2018 10:31:00 AM

TITLE OF PROJECT: CITY OF SANTA MONICA - CAMERA OBSCURA - EXTERIOR LIGHTING DRAWING NO: 6926 SOUTHWEST ELEVATION SOUTHEAST ELEVATION NORTHWEST ELEVATION NORTHEAST ELEVATION Capital Expenditure Managers 2450 Venture Oaks Way Suite 500 Sacramento, CA. 95833 (916) 648-9700 DRAWN BY: SHEET TITLE SCALE ARCHITECTURAL SERVICES 1437 4TH STREET, SUITE 300 SANTA MONICA, CA 90401 TEL. 310-458-2205 FAX. 310-399-1541 architecture@smgov.net CONSULTANTS SUBMITTED BY: Milutin Backovich, Licensed Engineer APPROVED BY: Miriam Mulder, City Architect CITY OF SANTA MONICA DEPARTMENT OF PUBLIC WORKS No. Description Date NOT FOR CONSTRUCTION PROJECT STATUS: 75% CONSTRUCTION DOCUMENTS PROJECT City of Santa Monica CAMERA OBSCURA EXTERIOR LIGHTING SP2430 SP-FILE NO: 2430 DRAWING NO: 6926 AS LIGHT STUDY RENDERING (2) E801 11/28/17 2/20/2018 10:31:01 AM