EUROSTER 2510TX USER MANUAL EUROSTER 2510TX

Similar documents
EUROSTER 2510 USER MANUAL 1 EUROSTER 2510

Operating your heating system with the Prefect PRE5701 Programable Thermostat

C-Stat 17-ZW User Instructions

CS027 User Instructions

ET4 heat/cool day RF programmable room thermostat. ET4 Receiver

ARATON 2100 TX 1 AURATON 2100 TX. Advanced Remote Control Programmable Thermostat

T105 Advanced Remote Control Programmable Thermostat. User Manual

Model: RT310i. Smartphone Controlled Thermostat. Installation Manual

OWNER S MANUAL. Part Number P RF

Edited by Foxit PDF Editor Copyright (c) by Foxit Software Comp. Programmable digital room thermostat. NEW software! Operating Instructions

Owner s Manual. Part Number 33CS250-RC

Easy-Stat. Wireless Programmable Room Thermostat Pt No

Programmable Electronic Thermostat

Installation, Start-Up, and Operating Instructions

CentaurStat 7 User Operating Instructions Central Heating Programmable Room ThermoStat

C7 Programmable, digital room thermostat. Operating Instructions

ESRTPRF. Wireless Programmable Room Thermostat, with Delayed & Optimum Start. User and Installation Instructions M/A MANUAL

Model: RT310RF. Installation Manual

AUTO CM CM USER GUIDE

Drayton Digistat +3RF

DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING 2 INSTALLATION

Model: Slimline-RF. 1 Slimline Series

Vokèra OpenTherm 711 with external sensor connected

Vokèra OpenTherm 711 without external sensor connected

ThermoPlus AS2-RF & ASR-RF Installation Instructions

irad Wireless Controller

Model: RT510RF. Installation Manual

CM907- TRV PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

Owners Manual. HTC621W 7-Day Programmable Thermostat 3600W. HTC625W 7-Day Programmable Thermostat 4000W

Model: PRT-TS / PRT-NTS

CM707. Programmable Room Thermostat with Optimum Start, Optimum Stop and Delayed Start. User Guide

3 Channel Multi-Purpose Programmer User Instructions

Model: Touch-RF. 1 Wireless Series

DT92 WIRELESS DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

4 in 1 Digital Thermostat Control

AURATON 2005 / 2005 TX

CM901 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

RGR150 USER S MANUAL. Wireless Rain Gauge with Thermometer and Clock

: PRT / PRT PRT / PRT-N1

Phone-A-Stat. MODEL Command Center With Thermostat Operation, Maintenance & Installation Manual. Introduction.

USER MANUAL MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. 5-2 Day Programmable Multi-Stage 2 Heat/1 Cool Heat Pump Digital Thermostat

WARNING Important Safety Information

Model: Available in : Sapphire Black and Glacier White. 1 Series

SINGLE-CHANNEL PROGRAMMER FITTING AND OPERATING INSTRUCTIONS

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

Table of Contents. Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure

Table of Contents. Model: Series. Available in : Sapphire Black and Glacier White. Product Image. 20 Table of Contents.

Model: RT310. Installation Manual

Table of Contents. Product Image 1 Locking/Unlocking the neoair 24 Table of Contents 2 Frost Protection 25 What is a Programmable Room Thermostat?

EUROSTER 1100E USER MANUAL 1 EUROSTER 1100E

DIGISTAT PROGRAMMABLE 24 HOUR ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat.

COMPUTHERM Q3 digital room thermostat

MC200. Users Instructions. HEATING DIVISION Hort Bridge Ilminster, Somerset TA19 9PS Tel: Fax:

ES3247B. 3 Channel Programmer. User and Installation Instructions

ST9400S User Guide. 1 Day Programmer, 2 channel With Boiler Service Reminder / Shut-down Feature

ECO AND DATE /06 ARTWORK DESCRIPTION. 22 page A6 : Saddle stitch (2-wire) 6 page : 4 colour : 170gsm Silk 18 page : 1 colour : 100gsm Silk

Cat No. 099A. Digital Programmable Thermostat for Weekday/Weekend Setting. User Maunal

Table of Contents. SLIMLINE Series MODEL: SLIMLINE

Installation & User s Instructions

ST9400A User Guide. Features

Programmable Thermostat

Climatouch /CT03TS/217S31 Programmable Universal Touch Screen thermostat

1. COMMISSIONING OF THE BOILER en DESCRIPTION FUNCTION BUTTON DESCRIPTION SYMBOL DISPLAY

RF Programmable Room Thermostat User Instructions

Contents. Box contents: JGSTAT2B (Black) Fixing screws (White) Icons used in this manual:

TYBOX PAC. * _rev1* User guide. Programmable thermostat for heat pumps

USER MANUAL 2000NC MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. Builder Series 5-2 Day Programmable Single Stage Heat/Cool Digital Thermostat

Instruction FH-CWP Thermostat

Underfloor Heating. undertile heating

DT90 DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

PROGRAMMABLE 7-DAY RF THERMOSTAT

Climapro 2. User manual. wireless room thermostat without receiver. To be left with the user.

Model: Slimline-B. Battery Series

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING 2 INSTALLATION. Premier Series

Programmable Thermostat

LONG-RANGE WIRELESS WEATHER STATION WITH IN-OUT THERMO-HYGROMETER AND RF CLOCK

Digital Electronic Thermostat With RF

REA22 Room Temperature Controller

Radio Controlled Kids Projection Clock with Nightlight

TWIN CHANNEL PROGRAMMER FITTING AND OPERATING INSTRUCTIONS

Operating Instructions Model : HC HC-N

Underfloor Heating Programmable Thermostat

User Guide Y9420H Sundial RF 2 Pack 2

lightwaverf Boiler Switch Model No. JSJSLW920 Instruction Manual Professional Series

Heating Controls Technical

PROGRAMMABLE 7-DAY THERMOSTAT

PROGRAMMABLE THERMOSTAT

Model: Touch-RS. 1 Touch-RS

L. Terminal block Connecting Label:

Heating is great when you control it. USER MANUAL. Wireless Programmable Room Thermostat. Model No.: LS Scan for App

PROGRAMMABLE ENERGY SAVING TIMER. ASAP Timers, LLC Multi-Family Timer Model A-1. User Manual

User Manual THR872CUK Wireless Programmable Thermostat

Digital Thermostat Models: VS30W and VS30B

Model: Available in: Sapphire Black and Glacier White. 1 Series

WARNING Important Safety Information

MAKING MODERN LIVING POSSIBLE INT INT EFIT 550. User Guide and Installation Manual. Danfoss Heating

Model : PRT-EN Model: PRT-EN1

Digital Electronic Thermostat With RF

CM921 - User Guide 1 day Wireless Programmable Room Thermostat with LoT technology

Transcription:

1 EUROSTER 2510TX Introduction Congratulations on the purchase of your new Digital Thermostat. Thanks to the latest microprocessor technology, the thermostat offers many convenient and energy-saving features. Please read the following instructions fully before installing your thermostat. B: Overview of features & functions Your Digital Thermostat incorporates preset daily programs to suit different user lifestyles. The thermostat can be programmed easily to accommodate exacting user needs. This user guide shows how to get the best from your Digital Thermostat. It is powered by 2 x AA batteries and can replace most domestic thermostats. Caution! The Digital Thermostat has been designed to switch a 230VAC supply. The maximum load is 6 Amps (resistive)/ 2 Amps (inductive). Installation Caution! Electricity can be lethal. Before beginning any work, ensure that the electricity supply is turned off at the mains. If in any doubt, contact a qualified electrician. If you currently have a thermostat connected by two wires, you can replace it directly with your new Digital Thermostat. If you are not replacing an existing thermostat, you must install a two-wire cable to your heating system. 1. Before carrying out any installation work, choose an appropriate location for Digital Thermostat using the following guidelines: a) Mount the Digital Thermostat approximately 1.6m above the floor. b) Only mount on interior walls (the thermostat is not for outdoor use) c) Avoid any location where the Digital Thermostat could be exposed to direct sunlight. d) Avoid any location in proximity to a heater, cooker, ventilation outlet or any appliance/fitting that generates heat. e) Avoid any location where there may be concealed boilers, pipework or chimney flues. f) Mount away from doors and the corners of rooms. 2. Detach the front cover by sliding it to the left. Remove screw in battery compartment. Open the front housing from the base by lifting from the left hand side. 3. Unscrew the retaining screw to open the protective cover. 4. Mount the Thermostat base on the wall in the desired location, ensuring that the hole in the wall is completely covered by the base. Check the wires come in through the protective cover hole.

2 5. Connect the two wires into terminals 1 & 2. The standard connections are shown on the pictures (without neutral and earth conductor) 6. 7. 8. 9. Note! If the existing installation has neutral or earth conductors, these must not be connected to the Digital Thermostat. They must be made electrically safe. Reattach the protective cover to the Digital Thermostat's base and secure it with the retaining screw. Reattach the front housing to the Digital Thermostat's base and secure it with the retaining screw. Insert 2 x AA batteries making sure they are the right way round as indicated and replace the front cover. Note: when replacing the batteries, the programs are held in memory for approx. 20 seconds only. RESET key once and ensure the Digital Thermostat is in the INITIAL mode LCD display Familiarise yourself with the LCD panel and the keys before programming.

3 Key function: - to enter programming mode - to view the Temperatures i - to enter TIME and DAY adjustment mode Reset - to reset the unit to INITIAL mode - to turn the thermostat ON/OFF - to enter Vacation mode. - to confirm setting - enter CT (COMFORT TEMPERATURE) mode - enter ET (EVENING TEMPERATURE) mode. + - - temporary TEMPERATURE OVERRIDE mode/ increase value adjustment - temporary TEMPERATURE OVERRIDE mode/decrease value adjustment Operation and Programming 1. To set clock and day: After inserting the batteries, or pressing the RESET key or key. The thermostat will enter TIME ADJUSTMENT mode and the HOUR will start to flash. + or - keys to adjust the HOUR setting. Press key to confirm setting. The MINUTE will now flash, press + or - Key to adjust MINUTE. Press key to confirm setting. The DAY will now flash, press + or - key to adjust day. Press key to confirm setting. This will confirm the setting of clock and day. The display will return into running mode. E.g. if the clock at 8:30 FRIDAY and the room temperature is 25 C. The Digital Thermostat is a weekly programmable thermostat, with 7 day/24 hour programs that can be set as required. For each hour you can set the Digital Thermostat so that either the CT (COMFORT) or ET (EVENING) temperature mode operates. The Digital Thermostat comes with a preinstalled program that will accommodate many users' requirements Heating & Air-Conditioning Program

4 Reviewing preset program To review the settings for the pre-installed program, press to enter the PROGAMMING mode. The preset program for Monday will show - 0:00 is displayed. Press +/- to show the temperature mode setting (either COMFORT or EVENING) for each hour. For example, the Monday program has: ET (EVENING temperature mode) 0.00 to 5.59 (Midnight to 5.59am) and 8.00 to 15:59 (8am to 3.59pm) CT (COMFORT temperature mode)6.00 to 7.59 (6am to 7.59am) 16.00 to 22.59 (4pm to 10.59pm) Note: 23.00 to 0.00 (11pm to Midnight) is set to ET (EVENING temperature mode). key and next day's temperature setting will be displayed. As before, use the + /- keys to show which temperature mode is operating for each hour. Repeat this procedure until Sunday has been reached. key to return to the RUNNING mode. Changing the preset program The preset program can be adjusted to meet your requirements. key to enter the PROGRAMMING mode. key to select the day you wish to adjust the program for. Use the + /- keys to select the hour you wish to adjust. Press or to change the temperature mode. For example, to change 12pm to 4.59pm on Saturday from COMFORT to EVENING temperature mode: to enter the PROGRAMMING MODE. key repeatedly until Saturday is displayed. + key repeatedly until 12.00 with CT is displayed. key - CT will change to ET. + key so the display advances to 13:00 and press the so that CT changes to ET. + key so the display advances to 14:00 and press the so that CT changes to ET. key to confirm the setting. The display will advance to Sunday - press the key again to return to the RUNNING mode. Note: do not set a program using 0.00 as either a start or end time. Set programs to begin or end at 23:00 or 1:00. The thermostat may not operate correctly if 0:00 is used. Viewing and changing the preset temperatures Each temperature mode is set at the following values: key to view CT or ET temperature mode. Press to view the CT setting or to view the ET setting (from the CT setting). With the temperature setting flashing, press +/- to change the temperature setting. key to confirm the setting and return to the RUNNING mode. Setting the temporary manual override for temperature Temporary manual override allows you to override the existing temperature setting for any period from 1 to 48hrs. +/- key to enter the MANUAL OVERRIDE TEMPERATURE mode. The temperature reading on the LCD panel will flash. Use +/- to set the desired temperature. Press to confirm the new temperature. H1 will show on the LCD panel and flash (indicating a 1 hour override). Use the + key to increase this up to a maximum of 48 hours as required. Press the key to confirm. Overriding the temperature mode (temporarily) You can override the programmed CT (COMFORT) or ET (EVENING) temperature mode (i.e. CT instead of ET, or vice versa) until the temperature mode is programmed to activate again. If the thermostat is currently running in ET mode, press the key to change to CT mode the thermostat will run CT mode

5 until the next ET program period activates. Similarly if CT is running, press the key to change to ET mode. The thermostat will continue to run in ET mode until the next CT program period activates. Note: the first hour of override will only run for a maximum of 45 minutes. Each subsequent hour of override will function for the full hour. For example, 2 hours of override will function for 1 hour 45 minutes Setting permanent/vacation temperature override The Digital Thermostat program can be overridden to give one constant temperature for any period between 1 and 99 days. This is particularly useful if you are going on holiday. key and the day bar on LCD will flash. Use the +/- keys to set the number of days override required. key to confirm. Use the +/- keys to select the required temperature. key to confirm. Note: If using the vacation mode for frost protection, some areas of the heating system may be in an exposed location outside the area monitored by the Digital Thermostat. Cancelling overrides Should you wish to cancel either the manual, temporary or permanent/vacation override, press either the or key to return to the RUNNING mode. Alternatively, press to turn the Thermostat off. Resetting the Digital Thermostat Should you wish to return the Thermostat to its original preset program (and erase any changes you have made) simply press the RESET key. Further adjustment The Digital Thermostat incorporates twin DIP switches on the circuit board at the rear of the front housing. DIP switch 1 adjusts the sensitivity of the thermostat. In the DOWN position if the temperature variation is greater than 0.5 C the thermostat is activated. In the UP position it will activate if the variation is greater than 0.2 C. DIP switch 2 switches between HEATING and AIR CONDITIONING. DOWN position selects HEATING control, UP position selects AIR CONDITIONING control. Sensor operation Your Digital Thermostat uses an advanced NTC thermistor to detect the temperature, located on the lower left-hand side of the circuit board. If the sensor is accidentally touched, you must allow a few minutes for the sensor to return to the normal temperature. The sensor measures the temperature once a minute. Technical specifications Temperature measuring range: 0-40 C Temperature control range 5 C - 30 C Batteries 2xAA (1.5VDC) Temperature scale division 0,5 C Differential: 0,4 C or 1 C Rated switching power 250V, 6A resistive load, 2A inductive load Minimum ON time: In heating mode: 1 mins In air conditioning mode: 3 mins Dimentions: length/width/height 130/78/30mm Operating temperature (of environment) 0 C 45 C Ingress Protection IP20

6 WIRELESS TEMPERATURE CONTROLLERS: USER MANUAL Important: Any guarantee claims will be processed only if both the transmitter and receiver have been delivered to the point of sale, accompanied with the guarantee certificate. Euroster with wireless technology TX RX A. Overview Programmable temperature controllers Euroster TX RX are a wireless version of the relevant wired models, with the same programming functions. Therefore, the user manual of the relevant wired model is attached herewith. The difference is in the method of transferring the switch on/ off signals. EUROSTER TX RX utilises wireless technology, thus eliminating the need for routing of cables between the transmitter unit EUROSTER TX and the appliance, which is controlled by receiver unit EUROSTER RX. The operating range of the transmitter/ receiver pair depends to a large extent on the materials used for construction of the building. In the open the operating range is ca. 100 m. With up to 30 m range inside buildings the signal will pass several storeys. In reinforced concrete enclosures signal attenuation is very high and consequently the operating range drops. IMPORTANT! The low battery lamp LED will come on when the voltage has dropped below the minimum admissible level. Then the batteries must be replaced and EUROSTER TX must be programmed anew. B. First start-up 1. Insert new alkali batteries 2. Fully extend the telescopic antenna of the RX unit 3. Green LED indicates that the receiver unit is in the range of the transmitter. For the first minute upon connection of the TX/ RX pair the green lamp comes on every 3 seconds to indicate communication between the units. After that time communication is tested every minute for ca. 1 second. When the green LED does not light up the receiver unit is beyond the range. 4. Red LED indicates that the heating/ cooling appliance has been switched on. C. Protections 1. If due to external interference such as strong electromagnetic pulse or low battery in EUROSTER TX confirmation of switch on/ off signal has not been received by EUROSTER RX for seven subsequent cycles the heating appliance will be switched off to prevent potential overheating. When communication has been restored the system automatically returns to the current program. EUROSTER TX must be programmed anew after each replacement of batteries. 2. Coded digital transmission technology, as used in EUROSTER TX allows for operation of several units in a limited area without any disturbance. A minimum distance of 0.5 m should be kept between two RX units. Modules are not interchangeable as the transmitter and receiver form a pair with the same unique code. The code is given both on the RX unit (sticker at the plug side) and on the TX unit (on the left-hand side in the battery compartment). For any doubts or queries, please do not hesitate to contact us or your local distributor. D. Operation As it is required due to one-way transmission of signal and as a protection of the controlled heating/ cooling appliance every minute a momentary coded signal is sent by EUROSTER TX to verify the status of the relay of EUROSTER RX, which is signalled by green LED. For this reason the on/ off lamp on the controller may come on before the appliance has been actually switched on. This difference should not exceed 1 minute. Similarly, this may

7 happen during switching off the appliance. Taking into account the heat capacity of buildings this has no effect on the energy efficiency and, consequently, on the heating cost. Note: The controller may be connected to an electrical, gas-fired or oil-fired appliance with rated power exceeding the contact rating only through an intermediate switch with load rating and performance appropriate for the controlled appliance parameters. Note: High inductive and capacitative loads should be avoided as they shorten the life of relay contacts. Note: Green LED on the receiver unit confirms receiving of signal from the transmitter. Normally it lights up at ca. 1 second intervals. If it does not, do the following: 1. Reduce the transmitter/ receiver distance 2. Check the battery charge status, and replace with new alkaline type ones, if required. With low batteries the operating range will be reduced and replacement is recommended. Red LED signals switching on of the heating or other controlled appliance. Danger! Hazardous voltage is present inside the enclosure. Any tampering with the unit may result in a life-threatening electrical injury! S1. Wiring example: EUROSTER TX RX connected to a heating/cooling appliance Legend: 1. Terminal block 2. Two-conductor cable, voltage-free relay output of EUROSTER RX, normally open, contact rating: 5A, 230 V AC 3. Antenna 4. EUROSTER RX (receiver) 5. Euroster TX installed at a preferred location

8 S2. Wiring example: EUROSTER TX RX connected to a gas-fired boiler Legend: 1. Terminal block 2. Two-conductor cable, voltage-free relay output of EUROSTER RX, normally open, contact rating: 5A, 230 V AC 3. Antenna 4. EUROSTER RX (receiver) 5. Euroster TX installed at a preferred location S3. Wiring example: EUROSTER TX RX connected to a heating water circulating pump Legend: 1. Heating boiler 2. Shutoff valve 3. Strainer 4. Heating water circulating pump 5. Check valve 6. Heating unit radiator 7. Euroster TX (transmitter unit) 8. Euroster RX (receiver unit) 9. Antenna 10.Terminal block 11.Two-conductor cable, voltage-free relay output of EUROSTER RX, normally open, contact rating: 5A, 230 V AC

E. Troubleshooting list 1. The controller does not switch on the heating appliance replace the batteries - use only new alkaline batteries; reset and program the controller; move the controller to another place; verify the operation of LEDs on the receiver unit (green and red); verify connection between the receiver and the controlled appliance; disconnect the receiver unit from the controlled appliance and check the operation of the latter; check if the code given on the transmitter is the same as on the receiver; fully extend the antenna. 2. Blinking LCD display on the controller replace the batteries - use only new alkaline batteries; reset and program the controller. 3. Blinking battery charge indicator on the LCD display: replace the batteries - use only new alkaline batteries; make sure the battery contacts are clean. 4. Lack of windmill icon on the LCD display, which indicates that the appliance is switched off:: verify the setting of DIP switches on the controller; verify the settings of operating parameters: day, hour, temperature. 9